Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24.326
Filter
1.
Front Oncol ; 14: 1459313, 2024.
Article in English | MEDLINE | ID: mdl-39351360

ABSTRACT

Recent research has revealed the important role of mechanical forces in the initiation and progression of tumors. The interplay between mechanical and biochemical cues affects the function and behavior of tumor cells during the development of solid tumors, especially their metastatic potential. The compression force generated by excessive cell proliferation and the tumor microenvironment widely regulates the progression of solid tumor disease. Tumor cells can sense alterations in compressive stress through diverse mechanosensitive components and adapt their mechanical characteristics accordingly to adapt to environmental changes. Here, we summarize the current role of compressive stress in regulating tumor behavior and its biophysical mechanism from the mechanobiological direction.

2.
ACS Nano ; 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-39353173

ABSTRACT

Understanding the dynamic features of severe acute respiratory coronavirus 2 (SARS-CoV-2) binding to the cell membrane and entry cells is crucial for comprehending viral pathogenesis and transmission and facilitating the development of effective drugs against COVID-19. Herein, we employed atomic force microscopy (AFM)-based single-molecule force spectroscopy (SMFS) to study the binding dynamics between the virus and cell membrane. Our findings revealed that the Omicron variant of SARS-CoV-2 virus-like particles (VLPs) exhibited a slightly stronger affinity for the angiotensin-converting enzyme-2 (ACE2) receptor compared with the Delta variant and was significantly higher than the wild-type (WT). Using a real-time force-tracing technique, we quantified the dynamic parameters for a single SARS-CoV-2 VLP entry into cells, showing that approximately 200 ms and 60 pN are required. The parameters aligned with the analysis obtained from coarse-grained molecular dynamics (CGMD) simulations. Additionally, the Omicron variant invades cells at a higher entry cell speed, smaller force, and higher probability. Furthermore, single-particle fluorescence tracking visually demonstrated clathrin-dependent endocytosis for SARS-CoV-2 entry into A549 cells. The dynamic features of endocytosis provide valuable insights into the SARS-CoV-2 entry mechanism and possible intervention strategies targeting the viral infection process.

3.
Int J Sports Physiol Perform ; : 1-11, 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-39353577

ABSTRACT

PURPOSE: To examine the test-retest reliability of countermovement jump (CMJ) and isometric strength testing measures in elite-level under-18 and under-23 academy football players. METHODS: A total of 36 players performed 3 maximal CMJs and isometric abductor (IABS), adductor (IADS), and posterior chain (IPCS) strength tests on 2 separate test days using dual force plates (CMJ and IPCS) and a portable strength testing device (IABS and IADS). Relative (intraclass correlation coefficient) and absolute (coefficient of variation, standard error of the measurement, and minimal detectable change [MDC%]) reliabilities for 34 CMJ, 10 IABS, 10 IADS, and 11 IPCS measures were analyzed using between-sessions best, mean, and within-session methods. RESULTS: For all methods, relative reliability was good to excellent for all CMJ and all IADS measures and poor to good for all IABS and IPCS measures. Absolute reliability was good (ie, coefficient of variation < 10%) for 27 (best) and 28 (mean) CMJ variables and for 6 (IABS and IADS) and 2 (IPCS) isometric measures. Commonly used CMJ measures (jump height, eccentric duration, and flight-time:contraction-time ratio) had good to excellent relative reliability and an MDC% range of 14.6% to 23.7%. Likewise, commonly used isometric peak force measures for IABS, IADS, and IPCS had good to excellent relative reliability and an MDC% range of 22.2% to 26.4%. CONCLUSIONS: Commonly used CMJ and isometric strength measures had good test-retest reliability but might be limited by their MDC%. Rate-of-force-development measures (for all isometric tests) and impulse measures (IPCS) are limited by poor relative and absolute reliability and high MDC%. MDC% statistics should be considered in the context of typical responsiveness.

4.
Sci Rep ; 14(1): 22761, 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-39354025

ABSTRACT

Existing deep foundation pit support structures are commonly composed of external earth-retaining structures, internal horizontal bracings, and vertical columns. A closed bracing system, often formed by a horizontal support through a bracket board, frequently impedes vertical excavation and soil removal operations in the foundation pit, and the processes of assembly and dismantling are complex and time-consuming. This study presents a combined support system and construction method consisting of cast-in-place piles and diagonal steel lattice braces. For sloped excavation, diagonal braces were constructed by slotting through the reserved soil, allowing the use of a single layer of support within the excavation depth. This approach significantly optimizes the construction process, reducing both project duration and overall cost. The field monitoring results indicated that the support method effectively controlled the lateral displacement of the pile bodies. Field monitoring results demonstrated that the proposed support system effectively controlled the lateral displacement of the pile bodies. The adoption of a support-first, excavation-second approach significantly controlled the settlement of the ground surface around the foundation pit, thereby preventing excessive increments in the axial force of the supports due to the large longitudinal depth excavation. The calculation results of the three-dimensional finite element model for foundation pit excavation and support indicate that the proposed support method results in a decreasing ratio of the maximum lateral deformation depth of the pile body, denoted as δh-m, to the excavation depth He as the excavation depth increases. This implied that the displacement of the pile body was strictly controlled. When the depth of the foundation pit excavation exceeded 10 m, the maximum lateral deformation occurred below 10 m along the pile shaft. The diagonal steel lattice braces transferred the load to the top of the cast-in-place piles at the bottom of the pit, where the stress concentration occurred. During construction, special attention must be paid to the strength of the connection between the pile top and the connecting beams.

5.
J Colloid Interface Sci ; 678(Pt C): 1259-1269, 2024 Sep 22.
Article in English | MEDLINE | ID: mdl-39357245

ABSTRACT

Folded protein hydrogels are emerging as promising new materials for medicine and healthcare applications. Folded globular proteins can be modelled as colloids which exhibit site specific cross-linking for controlled network formation. However, folded proteins have inherent mechanical stability and unfolded in response to an applied force. It is not yet understood how colloidal network theory maps onto folded protein hydrogels and whether it models the impact of protein unfolding on network properties. To address this, we study a hybrid system which contains folded proteins (patchy colloids) and unfolded proteins (biopolymers). We use a model protein, bovine serum albumin (BSA), to explore network architecture and mechanics in folded protein hydrogels. We alter both the photo-chemical cross-linking reaction rate and the mechanical properties of the protein building block, via illumination intensity and redox removal of robust intra-protein covalent bonds, respectively. This dual approach, in conjunction with rheological and structural techniques, allows us to show that while reaction rate can 'fine-tune' the mechanical and structural properties of protein hydrogels, it is the force-lability of the protein which has the greatest impact on network architecture and rigidity. To understand these results, we consider a colloidal model which successfully describes the behaviour of the folded protein hydrogels but cannot account for the behaviour observed in force-labile hydrogels containing unfolded protein. Alternative models are needed which combine the properties of colloids (folded proteins) and biopolymers (unfolded proteins) in cross-linked networks. This work provides important insights into the accessible design space of folded protein hydrogels without the need for complex and costly protein engineering, aiding the development of protein-based biomaterials.

6.
Dent Mater J ; 2024 Oct 02.
Article in English | MEDLINE | ID: mdl-39358306

ABSTRACT

The purpose of this study was to develop a new instrument to measure the mechanical properties of rotary endodontic Ni-Ti files (ProTaper Gold F2, ProTaper Ultimate F2, and HyFlex EDM Onefile), and to evaluate the overall utility of the device. The instrument was capable of analyzing the 6-axis force/torque generated by the files during cyclic dynamic movement in a metal curved artificial root canal, and doing automatic cyclic dynamic filing in a resin root canal with a preset vertical force limit by adopting a negative feedback mechanism. By analyzing the 6-axis force/torque, we were able to estimate the position and contact points of the files in the curved root canal. ProTaper Gold showed the highest force/torque in all directions. HyFlex EDM had the highest hysteresis ratio, centering ratio value and NCF (number of cycles to fatigue fracture), while the lowest vertical force.

7.
J Mol Model ; 30(11): 363, 2024 Oct 03.
Article in English | MEDLINE | ID: mdl-39361054

ABSTRACT

CONTEXT: The strength and nature of the two halogen bonds in the NCI···CH3I···-CN halogen-bonded ternary complex are studied in the gas phase via ab initio calculations. Different indicators of halogen bond strength were employed to examine the interactions including geometries, complexation energies, Natural Bond Order (NBO) Wiberg bond indices, and Atoms in Molecules (AIM)-based charge density topological properties. The results show that the halogen bond is strong and partly covalent in nature when CH3I donates the halogen bond, but weak and noncovalent in nature when CH3I accepts the halogen bond. Significant halogen bond cooperativity emerges in the ternary complex relative to the corresponding heterodimer complexes, NCI···CH3I and CH3I···-CN, respectively. For example, the CCSD(T) complexation energy of the ternary complex (-18.27 kcal/mol) is about twice the sum of the complexation energies of the component dimers (-9.54 kcal/mol). The halonium transfer reaction that converts the ternary complex into an equivalent one was also investigated. The electronic barrier for the halonium transfer was calculated to be 6.70 kcal/mol at the CCSD(T) level. Although the MP2 level underestimates and the MP3 overestimates the barrier, their calculated MP2.5 average barrier (6.44 kcal/mol) is close to that of the more robust CCSD(T) level. Insights on the halonium ion transfer reaction was obtained by examining the reaction energy and force profiles along the intrinsic reaction coordinate, IRC. The corresponding evolution of other properties such as bond lengths, Wiberg bond indices, and Mulliken charges provides specific insight on the extent of structural rearrangements and electronic redistribution throughout the entire IRC space. METHODS: The MP2 method was used for geometry optimizations. Energy calculations were performed using the CCSD(T) method. The aug-cc-pVTZ basis set was employed for all atoms other than iodine for which the aug-cc-pVTZ-PP basis set was used instead.

8.
J Texture Stud ; 55(5): e12868, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39350627

ABSTRACT

This study investigates the forces exerted on organs during swallowing, specifically focusing on identifying forces other than those resulting from direct organ contact. Using a swallowing simulator based on the moving particle method, we simulated the swallowing process of healthy individuals upon the ingestion of thickened foods, which were simulated as shear-thinning flow without yield stress. We extracted the resultant force vectors acting on the organs and shape of the bolus at each time interval. The simulation results confirmed that the bolus originates from tongue movement and is transferred between the oral cavity and pharynx, with each organ's coordinated movements with the tongue occurring at their respective positions, as indicated by the balance of the resultant force vectors. Utilizing the information about the resultant force vectors obtained through simulations, we calculated the physical parameters of impulse, energy, and power. The variations in these physical parameters were aligned with the behaviors of both the biological system and the food bolus during swallowing. The force values calculated from the simulations closely approximate the theoretical values. Furthermore, the forces calculated from the simulations were relatively smaller than the force values derived from pressure information, such as that from high-resolution manometry and tongue pressure sensors. This difference can be attributed to the simulations extracting only the forces exerted on the organ by the food bolus. Force information on organs has the potential to provide a new interpretation of conventional mechanical indicators such as manometry and tongue pressure sensors.


Subject(s)
Computer Simulation , Deglutition , Mouth , Pharynx , Tongue , Deglutition/physiology , Humans , Tongue/physiology , Pharynx/physiology , Mouth/physiology , Food , Models, Biological , Pressure , Biomechanical Phenomena , Manometry/methods , Adult , Male
9.
Mol Biol (Mosk) ; 58(2): 314-324, 2024.
Article in Russian | MEDLINE | ID: mdl-39355888

ABSTRACT

Titin is a multidomain protein of striated and smooth muscles of vertebrates. The protein consists of repeating immunoglobulin-like (Ig) and fibronectin-like (FnIII) domains, which are ß-sandwiches with a predominant ß-structure, and also contains disordered regions. In this work, the methods of atomic force microscopy (AFM), X-ray diffraction, and Fourier transform infrared spectroscopy were used to study the morphology and structure of aggregates of rabbit skeletal muscle titin obtained in two different solutions: 0.15 M glycine-KOH, pH 7.0 and 200 mM KCl, 10 mM imidazole, pH 7.0. According to AFM data, skeletal muscle titin formed amorphous aggregates of different morphologies in the above two solutions. Amorphous aggregates of titin formed in a solution containing glycine consisted of much larger particles than aggregates of this protein formed in a solution containing KCl. The "KCl-aggregates" according to AFM data had the form of a "sponge"-like structure, while amorphous "glycine-aggregates" of titin formed "branching" structures. Spectrofluorometry revealed the ability of "glycine-aggregates" of titin to bind to the dye thioflavin T (TT), and X-ray diffraction revealed the presence of one of the elements of the amyloid cross ß-structure, a reflection of ~4.6 Å, in these aggregates. These data indicate that "glycine-aggregates" of titin are amyloid or amyloid-like. No similar structural features were found in "KCl-aggregates" of titin; they also did not show the ability to bind to thioflavin T, indicating the non-amyloid nature of these titin aggregates. Fourier transform infrared spectroscopy revealed differences in the secondary structure of the two types of titin aggregates. The data we obtained demonstrate the features of structural changes during the formation of intermolecular bonds between molecules of the giant titin protein during its aggregation. The data expand the understanding of the process of amyloid protein aggregation.


Subject(s)
Connectin , Microscopy, Atomic Force , Muscle, Skeletal , Protein Aggregates , Connectin/chemistry , Connectin/metabolism , Connectin/genetics , Rabbits , Animals , Muscle, Skeletal/metabolism , Muscle, Skeletal/chemistry , Spectroscopy, Fourier Transform Infrared , X-Ray Diffraction , Benzothiazoles
10.
Trop Anim Health Prod ; 56(8): 313, 2024 Oct 02.
Article in English | MEDLINE | ID: mdl-39356375

ABSTRACT

This study investigated the effects of age and sex on carcass and meat characteristics of one of Thailand's major indigenous chicken breeds, the white-tailed yellow native chicken (NC). A total of 120 one-day-old NC (60 males and 60 females) were raised, and harvested at either 16, 20 or 24 weeks. The results showed that body, carcass, breast and fillet weights did not differ (P > 0.05) between 16- and 20-week-old NC, but were lower (P < 0.05) than those of 24-week-old NC. Male NC had higher (P < 0.05) body, carcass, wing, back and thigh weights than female NC. Neither sex nor age affected muscle pH, sarcomere length, redness and yellowness, guanosine monophosphate, and hypoxanthine. The interaction between age and sex was significant (P < 0.05) for %dressing, %leg, L*, C14:1, C18:1n9 and C20:4n6. Shear force was lower in 16-week-old NC (P < 0.05). The 24-week-old NC had lower (P < 0.05) C13:0, C16:0, C18:0, C18:2n6t, C20:4n6, C22:6n-3, intramuscular fat and inosine 5'-monophosphate levels and higher (P < 0.05) C18:2n6c, C18:3n-3 and C20:3n-6 levels than the 16- and 20-week-old NC. Male NC had higher (P < 0.05) C13:0-, C14:0-, C18:2n6t-, C20:3n-6- and lower inosine levels than female NC. In conclusion, these data highlight age- and sex-specific differences in carcass and meat quality of NC and provide relevant information to support consumer-oriented decisions on the production, processing and nutritional value of NC.


Subject(s)
Chickens , Fatty Acids , Meat , Animals , Male , Female , Chickens/growth & development , Chickens/physiology , Meat/analysis , Sex Factors , Age Factors , Fatty Acids/analysis , Thailand , Ribonucleotides/analysis , Muscle, Skeletal/chemistry
11.
J Neurophysiol ; 2024 Oct 03.
Article in English | MEDLINE | ID: mdl-39361732

ABSTRACT

A recent line of work suggests that the net behavior of the foot-ground interaction force provides insight into quiet-standing-balance dynamics and control. Through human subject experiments, Boehm et al. found that the relative variations of the center of pressure and force orientation emerge as a distinct pattern in the frequency domain, termed the "intersection-point height." Subsequent empirical and simulation-based studies showed that different control strategies are reflected in the distribution of intersection-point height across frequency. To facilitate understanding of the strengths and limitations of the intersection-point height in describing the dynamics and control of standing, the present work establishes a spectral-based method that also enables derivation of a closed-form estimate of the intersection-point height from any linear model of quiet stance. This new method explained observations from prior work, including how the measure captures aspects of control and physiological noise. The analysis presented herein highlights the utility of the frequency-dependent foot-force dynamics in probing the balance controller and provides a tool for model development and validation to further our understanding of the neuromotor control of natural upright posture in humans.

12.
Nano Lett ; 2024 Oct 03.
Article in English | MEDLINE | ID: mdl-39361809

ABSTRACT

Realizing magnetic skyrmions in two-dimensional (2D) van der Waals (vdW) ferromagnets offers unparalleled prospects for future spintronic applications. The room-temperature ferromagnet Fe3GaTe2 provides an ideal platform for tailoring these magnetic solitons. Here, skyrmions of distinct topological charges are artificially introduced and engineered by using magnetic force microscopy (MFM). The skyrmion lattice is realized by a specific field-cooling process and can be further erased and painted via delicate manipulation of the tip stray field. The skyrmion lattice with opposite topological charges (S = ±1) can be tailored at the target regions to form topological skyrmion junctions (TSJs) with specific configurations. The delicate interplay of TSJs and spin-polarized device current were finally investigated via the in situ transport measurements, alongside the topological stability of TSJs. Our results demonstrate that Fe3GaTe2 not only serves as a potential building block for skyrmion-based spintronic devices, but also presents prospects for Fe3GaTe2-based heterostructures with the engineered topological spin textures.

13.
J Biomech ; 176: 112351, 2024 Sep 26.
Article in English | MEDLINE | ID: mdl-39361980

ABSTRACT

Inverse dynamic analysis is a technique used during gait analysis to estimate intersegmental forces and net joint moments. Inverse dynamic calculations are susceptible to various forms of error. One such error is force plate drift, often produced by humidity condensing within the input connectors and electronics, causing an undesired change in output over time. This can be particularly concerning for movement laboratories where inverse dynamics are considered in clinical decision-making processes. Manufacturers will provide tolerance levels for drift. However, levels of acceptable drift are rarely considered from a clinical perspective. Therefore, this study aims to establish clinically acceptable limits of force plate drift error, induced by applying systematic errors to force plate channels, on predicted lower limb joint moments during gait. Gait data of 10 children with typical development were analysed and induced errors of 0.5 N, 1 N, 1.5 N, 3 N, 6 N and 12 N were incrementally applied to the horizontal and vertical force channels. Data were recalculated for each increment and mean profiles compared to an error free mean (±1SD) band. Error was deemed clinically significant when moments fell outside the mean (±1SD) band. Induced error at 6 N and above was sufficient to cause a clinically significant change. Sagittal and coronal plane moments at the hip were most affected, followed by the knee and then the ankle. While manufacturer guidelines for acceptable drift are usually well below 6 N, care is needed when using force plates over several minutes or more as drift may eventually exceed clinically acceptable limits.

14.
J Mol Graph Model ; 133: 108875, 2024 Sep 26.
Article in English | MEDLINE | ID: mdl-39362061

ABSTRACT

Cytochrome P450 (CYP) enzymes play essential roles in the synthesis and metabolic activation of physiologically active substances. CYP has a prosthetic heme (iron protoporphyrin IX) in its active center, where Fe ion (heme-Fe) is deeply involved in enzymatic reactions of CYP. To precisely describe the structure and electronic states around heme-Fe, we modified the force fields (FFs) around heme-Fe in molecular mechanics (MM) simulations and conducted ab initio fragment molecular orbital (FMO) calculations for the CYP-ligand complex. To describe the coordination bond between heme-Fe and its coordinated ligand (ketoconazole), we added FF between heme-Fe and the N atom of ketoconazole, and then the structure of the complex was optimized using the modified FF. Its adequacy was confirmed by comparing the MM-optimized structure with the X-ray crystal one of the CYP-ketoconazole complex. We also performed 100 ns molecular dynamics simulations and revealed that the coordination bonds around heme-Fe were maintained even at 310 K and that the CYP-ketoconazole structure was kept similar to the X-ray structure. Furthermore, we investigated the electronic states of the complex using the ab initio FMO method to identify the CYP residues and parts of ketoconazole that contribute to strong binding between CYP and ketoconazole. The present procedure of constructing FF between heme-Fe and ketoconazole can be applicable to other CYP-ligand complexes, and the modified FF can provide their accurate structures useful for predicting the specific interactions between CYP and its ligands.

15.
Colloids Surf B Biointerfaces ; 245: 114281, 2024 Sep 30.
Article in English | MEDLINE | ID: mdl-39362072

ABSTRACT

Natural rubber originates from the coagulation of rubber particles (RP) from Hevea brasiliensis latex. The size distribution of Hevea RP is bimodal with the presence of small rubber particles (SRP) and large rubber particles (LRP). This study aims at getting a better understanding of the early coagulation steps of Hevea RP taking into account the particle size. SRP and LRP were obtained by centrifugation of freshly tapped ammonia-free latex from RRIM600 clone. Size and zeta potential measurements showed that both RP fractions were efficiently separated and stable in basic buffer. SRP and LRP dispersions were placed in a Langmuir trough and RP were let to adsorb at the air-liquid interface to form interfacial films. Surface tension and ellipsometry indicate that the formation kinetics and the stabilization of the film at the air-liquid interface are faster for SRP than LRP. Moreover, the arrangement of RP at the interface differs between SRP and LRP, as shown by Brewster angle microscopy, atomic force microscopy and confocal laser scanning microscopy. First, the RP membrane and cis-1,4-polyisoprene core spread at the air-liquid interface before clustering. Then, while the SRP fuse, the LRP keep their structure in individual particles in floating aggregate. The role of the non-isoprene molecules on the different organization of SRP and LRP films is discussed, the one of the two major RP proteins, SRPP1 (Small Rubber Particle Protein) and Rubber Elongation Factor (REF1) in the early coagulation steps.

16.
Article in English | MEDLINE | ID: mdl-39363573

ABSTRACT

Aiming to simplify the data acquisition process for balance diagnosis and focused on muscle, a direct factor affecting balance, to assess and judge postural stability. Utilizing a publicly available kinematic dataset, the research retained 3D coordinates and mechanical data for 8 markers on the lower limbs. By integrating this data with the musculoskeletal model in OpenSim, inverse kinematic calculations were performed to derive muscle forces. These forces, alongside the coordinates, were split into an 8:2 training and test set ratio. A neural network was then developed to predict muscle forces using normalized coordinate data from the training set as input, with corresponding muscle force data as training labels. The model's accuracy was confirmed on the test set, achieving coefficients of determination (R2) above 0.99 for 276 muscle forces. Furthermore, the Force Maximum Percentage Difference (FMPD) was introduced as a novel criterion to evaluate and visualize lower limb balance, revealing significant discrepancies between the patient and control groups. This study successfully demonstrates that the neural network model can precisely predict lower limb muscle forces using reduced markers and introduces FMPD as an effective tool for assessing limb balance, providing a robust framework for future diagnostic and rehabilitative applications.

17.
Expert Opin Drug Deliv ; : 1-11, 2024 Oct 04.
Article in English | MEDLINE | ID: mdl-39355986

ABSTRACT

OBJECTIVE: This noninvasive study aimed to understand the interaction between shield-triggered autoinjectors (AI) and skin at the point of activation, hypothesizing that the AI's housing absorbs a significant amount of the user-applied force depending on shield design and skin characteristics. METHODS: Twenty-seven volunteers used a test device measuring applied force versus shield force and indentation depth relative to shield length (2,4,6,8 mm) in standing and sitting positions. RESULTS: Significant differences were found between applied and shield force for the different shield lengths. Shorter shields resulted in significantly lower force transfer coefficients, with means ranging from 0.72 for the 2 mm shield to 0.94 for the 8 mm shield. ANOVA revealed statistically significant factors (p < .05), including position and gender, with females generally having lower coefficient values. Indentation depth increased with higher forces and varied significantly between positions without significant shield length impact. CONCLUSION: The findings confirm that an increase in shield length at the point of activation reduces skin friction with the housing, resulting in less force loss and a lower device activation force perceived by the user. Force loss can be further reduced by standing up. Understanding device-tissue interactions will support development of better AIs with fewer user failures.

18.
Sci Rep ; 14(1): 22903, 2024 Oct 02.
Article in English | MEDLINE | ID: mdl-39358401

ABSTRACT

To prevent the early breakage of anchor cables under shear loads in support engineering, a combined structure of Anchor Cable with C-shaped Tube (ACC) has been proposed. The shear resistance enhancement mechanism of this structure and the mechanisms of various influencing factors have yet to be fully revealed. A refined nonlinear finite element model of ACC was original established using ABAQUS software, taking into account the actual structure of the steel strands and the interactions, such as contact and failure between the various components. Various anchor cable pretension forces and block strengths were set to investigate their effects on the shear mechanical response of ACC. The results successfully demonstrated a high correlation between peak shear load and pretension force. The results demonstrate that an increase in pretension force reduces the ACC's peak shear load and break displacement. Additionally, the structure exhibited higher flexural stiffness, the block strength was mobilized earlier, and the block failed locally more quickly. Under high pretension forces, the system exhibited higher shear stiffness in the early stages of shearing due to the influence of the axial force component. With low pretension forces, the ACC exhibited a larger break displacement due to the minor tensile deformation at the shear plane position for the same shear displacement. At low pretension forces, the structure's bending angle increased more rapidly during the middle and later stages of shearing, accompanied by a larger break displacement. Both of these factors led to a greater bending angle at the shear plane position at the point of failure. The results reveal the characteristic of the peak shear load initially increasing and then decreasing with the increase in test block strength, along with its underlying mechanism. As the block strength increased, the bending angle of the structure at the shear plane position increased more rapidly, resulting in higher shear stiffness. With high block strength, the combination of smaller break displacement and greater shear stiffness led to an initial increase followed by a decrease in peak shear load. A comprehensive RSSB (Relative Stiffness between Structure and Test Block) that considers both structural and test block stiffness was proposed. The deformation pattern of the structure was controlled by the RSSB. The higher the RSSB, the wider the plastic hinge extension range for the same shear displacement, the smaller the bending angle at the shear plane position, and the smaller the maximum curvature of the structure. The contact force of the C-shaped tube generally exhibited a "single peak" distribution. As the shear displacement increased, the peak position of the contact force moved away from the shear plane, and the maximum contact force increased rapidly and remained relatively stable. At the end of the shearing process, the contact force of the C-shaped tube exhibited a "double peak" distribution.

19.
Front Cell Dev Biol ; 12: 1472575, 2024.
Article in English | MEDLINE | ID: mdl-39359720

ABSTRACT

Introduction: Fat grafting often yields inconsistent and suboptimal results, necessitating improved fat processing techniques. A stromal vascular fraction (SVF) gel created using mechanical emulsification demonstrates superior retention rates to conventional Coleman fat grafts. Methods: This study investigated the mechanisms at play by transplanting fat aspirates from liposuction patients-either processed as Coleman fat grafts or further refined into an SVF gel via mechanical shear force-onto the backs of nude mice. Results: The retention rate of the SVF gel after transplantation surpassed that observed for Coleman fat. Hematoxylin and eosin (HE) staining and immunofluorescence results demonstrated that the SVF gel group could form new adipose tissue characterized by well-organized mature fat structures. Mechanical shear force application induced increased mesenchymal stem cell abundance. Rather than merely surviving regeneration, fat was regenerated after transplantation, and the regenerated cells were mainly from mice, which was supported by microarray analysis. RNA-seq highlighted 601 genes expressed between SVF gel and Coleman fat groups, with 164 genes upregulated (cell cycle processes), and 437 genes downregulated (lipid metabolism). Discussion: The application of mechanical shear force reduces the risk of complications and fosters cell proliferation and division, thereby enhancing the retention and regeneration of transplanted fat.

20.
3D Print Addit Manuf ; 11(4): e1656-e1669, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39360132

ABSTRACT

The present study proposes a comprehensive 3D computational fluid dynamics-discrete element method (CFD-DEM) coupled simulation model to investigate the particle dynamics induced by SS316L metal vapor spouting during single-scan-track laser powder bed fusion (L-PBF) processing. The model provides the ability to examine the effects of nonconventional process variables such as the chamber pressure and gravitational force on the suppression of the spatter and denudation phenomena. The simulation results imply that adjusting the gravitational force provides an effective technique for suppressing both spatter formation and powder bed denudation. In addition, the chamber pressure has only a marginal effect on the denudation phenomenon. In particular, under a higher operating pressure, the metal vapor tends to spout in the upward direction, while under a lower pressure, the spouting is more radially distributed. As a result, the simulation results obtained in this study have suggested that the chamber pressure and gravitational force may both provide feasible approaches for suppressing the spattering and denudation phenomena, particularly in the L-PBF processing of light-weight materials.

SELECTION OF CITATIONS
SEARCH DETAIL