Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 161
Filter
1.
Open Heart ; 11(1)2024 Jan 06.
Article in English | MEDLINE | ID: mdl-38184301

ABSTRACT

BACKGROUND: Patent foramen ovale (PFO) closure is traditionally guided by transoesophageal echocardiography (TEE) under general anaesthesia, which prolongs procedure duration and increases costs and risks. A transnasal echocardiography with a microTEE-probe (microTNE) is tolerated under conscious sedation and offers an effective alternative to TEE. The aim of this study was to compare the feasibility, safety and time expenditure of PFO closure using conventional TEE versus microTNE guidance. METHODS: Consecutive patients assigned for PFO losure in Helsinki University Hospital from 2003 to 2021 were included in the study (n=336). TEE with general anaesthesia was used until November 2018 (n=167) while microTNE-guided PFO closure (n=169) under conscious sedation was the principal method thereafter. Patients were followed for 3 months after PFO closure. RESULTS: The microTNE-route success rate was 97.2% vs TEE 100% (p=0.06) and procedure success rate was 97.7% with microTNE and 96.0% with TEE-guidance (p=0.54). The procedure time was significantly shorter with microTNE 21±7 min than with TEE 30±13 min (p<0.001). At the beginning of microTNE era, nasal bleeding complication was quite frequent; however, overall complication rates were equal between the groups. However, C reactive protein (CRP) increase was significantly milder with microTNE than TEE 1.0±2.9 vs 3.0±4.0 mg/L (p<0.001). An increase in CRP was independently associated with procedure type (p=0.004) and time (p=0.003). CONCLUSIONS: MicroTNE is a feasible and safe alternative for PFO closure guidance. MicroTNE under conscious sedation shortens procedure duration and induces a milder inflammatory reaction than conventional TEE under general anaesthesia.


Subject(s)
Echocardiography, Transesophageal , Echocardiography , Humans , C-Reactive Protein , Hospitals, University
3.
J Tehran Heart Cent ; 18(3): 228-231, 2023 Jul.
Article in English | MEDLINE | ID: mdl-38146408

ABSTRACT

Partial anomalous pulmonary venous return (PAPVR) is a rare congenital heart malformation in which 1 or more pulmonary veins drain into the systemic venous circulation or directly into the right atrium instead of the left atrium. It may occur alongside other congenital heart defects, including atrial septal defect (ASD). All patients with newly diagnosed ASD must be evaluated thoroughly for the likelihood of PAPVR to select surgical or percutaneous procedures. Here, we describe a 10-year-old girl with PAPVR who underwent percutaneous device closure of her secundum ASD with her PAPVR neglected at 3 years of age. We had to correct the anomalous venous connection by removing the device during an intricate procedure. The typical connection of the pulmonary veins to the left atrium was reported on her postoperative echocardiography 1 day after surgery. The patient was discharged without complications, and her first follow-up visit 7 days after discharge was unremarkable. While the most accurate diagnostic tools for PAPVR are cardiovascular magnetic resonance imaging and computed tomographic angiography, a careful examination of the pulmonary veins during pulmonary angiography or transesophageal echocardiography in children helps identify PAPVR in patients with ASD.

9.
Heart ; 109(23): 1741-1750, 2023 11 10.
Article in English | MEDLINE | ID: mdl-37380331

ABSTRACT

OBJECTIVE: Despite the establishment of transcatheter closure as the treatment of choice in adults with secundum atrial septal defects (ASDs), the effectiveness of this approach in the elderly is disputed. This systematic review and meta-analysis aims to explore the impact of transcatheter ASD closure in patients ≥60 years old. METHODS: We systematically searched four major electronic databases (PubMed, CENTRAL (Cochrane Central Register of Controlled Trials), Scopus and Web of Science), ClinicalTrials.gov, article references and grey literature. Primary outcomes were the right ventricular end-diastolic diameter (RVEDD) and the New York Heart Association functional class change, whereas secondary outcomes included systolic pulmonary arterial pressure (sPAP), left ventricular end-diastolic diameter (LVEDD), brain natriuretic peptide (BNP), tricuspid valve regurgitation (TR) change, as well as the rate of atrial arrhythmias and all-cause mortality. RESULTS: In total, 18 single-arm cohorts comprising 1184 patients were included. RVEDD was reduced after ASD closure (standardised mean difference (SMD) -0.9, 95% CI -1.2 to -0.7). Elderly patients had 9.5 times higher odds of being asymptomatic after ASD closure (95% CI 5.06 to 17.79). Furthermore, ASD closure improved sPAP (mean difference (MD) -10.8, 95% CI -14.6 to -7), LVEDD (SMD 0.8, 95% CI 0.7 to 1.0), TR severity (OR 0.39, 95% CI 0.25 to 0.60) and BNP (MD -68.3, 95% CI -114.4 to -22.1). There was a neutral effect of ASD closure on atrial arrhythmias. CONCLUSIONS: Transcatheter ASD closure is beneficial for the elderly population since it improves functional capacity, biventricular dimensions, pulmonary pressures, TR severity and BNP. However, the incidence of atrial arrhythmias did not change significantly after the intervention. PROSPERO REGISTRATION NUMBER: CRD42022378574.


Subject(s)
Atrial Fibrillation , Heart Septal Defects, Atrial , Tricuspid Valve Insufficiency , Adult , Humans , Aged , Middle Aged , Heart Septal Defects, Atrial/surgery , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Treatment Outcome
10.
Sultan Qaboos Univ Med J ; 23(Spec Iss): 44-50, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38161760

ABSTRACT

Sinus venosus atrial septal defects present a wide variety of anatomical features and are frequently associated with partial anomalous pulmonary venous drainage of one or more right pulmonary veins. Surgical correction used to be the standard treatment. In recent times, transcatheter correction of superior sinus venosus atrial septal defects has come into vogue. The transcatheter closure of these defects with covered stents at a tertiary care centre in Oman between 2018 and 2023 is reported.


Subject(s)
Heart Septal Defects, Atrial , Pulmonary Veins , Humans , Heart Septal Defects, Atrial/surgery , Pulmonary Veins/surgery , Pulmonary Veins/abnormalities , Stents , Oman
11.
J. Transcatheter Interv ; 31: eA20230010, 2023. ilus.; vid.
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1516849

ABSTRACT

A comunicação interatrial do tipo seio venoso superior geralmente acompanha-se de uma conexão venosa anômala de veia ou veias pulmonares superiores ou médias direitas, que drenam diretamente na veia cava superior ou, ainda, na junção cavoatrial. Relatamos o caso de uma paciente do sexo feminino, de 62 anos, com diagnóstico de comunicação interatrial do tipo seio venoso, com sobrecarga das câmaras direitas, para quem foi planejado o procedimento de oclusão percutânea do defeito por meio da realização prévia de tomografia cardiovascular e, sequencialmente, estudo anatômico tridimensional, com o software de acesso público 3D Slicer. Além disso, foi realizada a impressão do modelo em resina para inspeção e simulação de implante de um stent. A paciente foi tratada de maneira percutânea com um stent Chetham-Platinum coberto de 60mm de extensão, com oclusão total do defeito, ausência de shunts residuais e direcionamento do fluxo da veia pulmonar superior direita para o átrio esquerdo por comunicação posterior entre os átrios, condição essencial para a realização desse tipo de procedimento. O planejamento do procedimento de oclusão percutânea da comunicação interatrial do tipo seio venoso passa por avaliação criteriosa dos exames de imagem. A impressão de modelos virtuais ou físicos, derivados da angiotomografia cardíaca, é fundamental para estudo detalhado do defeito e das estruturas anatômicas associadas, minimizando a ocorrência de complicações.


A superior sinus venosus atrial septal defect is usually accompanied by an anomalous venous connection to a right superior or middle pulmonary vein or veins, draining directly into the superior vena cava or even into the cavoatrial junction. This is a case report of a 62-year-old female patient, diagnosed with a sinus venosus atrial septal defect, with overload of the right chambers, for whom a percutaneous occlusion procedure was planned, using a previous cardiovascular tomography and, sequentially, a three-dimensional anatomical study, with the publicly available software 3D Slicer. In addition, a resin model was printed for inspection and simulation of a stent implantation. The patient was treated percutaneously with a 60-mm covered Chetham-Platinum stent, with total occlusion of the defect, absence of residual shunts, and draining flow from the right superior pulmonary vein to the left atrium, through a posterior communication between the atria, a sine qua non prerequisite to perform this type of procedure. Planning of the percutaneous occlusion procedure of the sinus venosus atrial septal defect involves careful evaluation of imaging tests. The printing of virtual or physical models, derived from computed tomography angiography of the heart, is essential for a detailed study of the defect and associated anatomical structures, minimizing the occurrence of complications.

14.
Circ Cardiovasc Interv ; 15(9): e012048, 2022 09.
Article in English | MEDLINE | ID: mdl-36126135

ABSTRACT

BACKGROUND: Two separate ostium secundum atrial septal defects are a challenging substrate for device closure due to lack of a well-described strategy or an adequately evaluated protocol. METHODS: This is a prospective study comprising 20 patients with 2 atrial septal defects who underwent device closure. All of them underwent balloon interrogation (BI) of the intervening tissue to decide 1- versus 2-device strategy. During BI, if the flow through both the defects could be stopped completely implying adequate mobility of the separating tissue, a single device strategy was used. The size of the device in this subset was determined by BI diameter. In case the flow persisted, 2 devices were used to close the defects separately. RESULTS: The mean age was 24±17 years. The main defect size was (mean 14.5 mm±SD 2.69 mm), whereas the second defect measured (mean 8.5±SD 3.02 mm). The tissue separating the 2 defects was measured (mean 6.1±SD 2.6 mm). In 15 of them, based on the BI results, a single device was used successfully to close both the defects without a residual shunt. In the remaining 5 patients, 2 devices were used. There were no complications during the procedure or at follow-up period of 41.9±16.9 months. CONCLUSIONS: BI in patients with 2 atrial septal defects is helpful in defining 1- versus 2-device strategies and in choosing the size of the device to be used. Nearly 3/4 of the patients may get away with a single device for closing both the defects successfully thereby decreasing the cost and complexity of the procedure.


Subject(s)
Cardiac Catheterization , Heart Septal Defects, Atrial , Adolescent , Adult , Child , Echocardiography, Transesophageal , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/therapy , Humans , Prospective Studies , Treatment Outcome , Young Adult
16.
Circ Cardiovasc Imaging ; 15(7): e014138, 2022 07.
Article in English | MEDLINE | ID: mdl-35861980

ABSTRACT

BACKGROUND: Although the transcatheter closure of atrial septal defect was established as the treatment of choice several decades ago, the process of device neoendothelialization (NE) in humans is not well understood. We aimed to measure the extent of device NE using cardiac computed tomography angiography and analyze its risk factors. METHODS: Between January 2005 and February 2021, we retrospectively reviewed 164 devices of 112 patients on cardiac computed tomography angiography. We investigated device shape, contrast opacification within the device that differentiated device NE, and device-related thrombosis or vegetation. Risk factor analysis for major adverse cardiovascular events and incomplete NE according to the postprocedural period was performed. RESULTS: Seventy patients (62.5%) were women, with a median (range) age at the time of device closure of 44.5 (0.6-79.2) years. The mean (±SD) defect size was 16.6 (±7.8) mm, and patients were followed for 35.9±33.9 months. After 6 months of device implantation, 35% of the devices (42/120) had incomplete NE. The intensity of intradevice opacification shifted from complete to partial or nonopacification over time (P<0.001), and a similar pattern was observed in the shunt flow (P<0.001). The bulkiness of devices also decreased in proportion to the postprocedural period (P<0.001). Risk analysis revealed device diameter (hazard ratio, 1.18 [95% CI, 1.04-1.27]; P<0.001) as the only significant factor of incomplete NE and major adverse events. CONCLUSIONS: Incomplete NE of atrial septal defect devices was identified on cardiac computed tomography angiography in significant numbers after 6 months of the procedure. The device diameter was related to incomplete NE and major adverse events. Further prospective and multicenter studies are warranted to validate this new assessment of device NE.


Subject(s)
Computed Tomography Angiography , Heart Septal Defects, Atrial , Cardiac Catheterization , Female , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/surgery , Humans , Male , Prostheses and Implants , Retrospective Studies , Treatment Outcome
17.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1431305

ABSTRACT

Introducción: El síndrome de Noonan es un trastorno genético relacionado principalmente con la mutación del gen PTPN11. Reporte del caso: Recién nacido varón de 34 semanas de edad gestacional con ultrasonidos obstétricos que muestran higroma quístico, hidronefrosis renal bilateral, y polihidramnios. Al nacimiento, presentó edema nucal, puente nasal ancho, pabellón auricular de implantación baja, y criptorquidia derecha. Además, defecto del tabique auricular, ausencia de vena cava inferior, hipertensión pulmonar, conducto arterioso persistente y dificultad respiratoria. El resultado del análisis del panel de 14 genes mostró una mutación del gen MAP2K1 y una variante de significado incierto en el gen CBL, confirmando el diagnóstico del síndrome de Noonan negativo para PTPN11. Durante el seguimiento, también se le diagnosticó blefaroptosis izquierda y reflujo gastroesofágico. Conclusión: El presente caso destaca la amplia variedad de características fenotípicas en un paciente con síndrome de Noonan, con sospecha al nacimiento y confirmado durante el seguimiento.


Background: Noonan syndrome is a genetic disorder mostly related to PTPN11 gene mutation. Report Case: Newborn male of 34 weeks of gestational age with obstetric ultrasounds showing cystic hygroma, bilateral renal hydronephrosis, and polyhydramnios. At born, he presented nuchal edema, wide nose, low-set ears, and right cryptorchidism. Additionally, he presented atrial septum defect, absence of inferior vena cava, mild pulmonary hypertension, persistent ductus arteriosus, and respiratory distress. The result of the 14-gene panel analysis showed a MAP2K1 gene mutation and a variation of uncertain significance in the CBL gene, confirming the diagnosis of PTPN11- negative Noonan syndrome. During the follow-up, he was additionally diagnosed with blepharoptosis of left eye and gastroesophageal reflux disease. Conclusion:This report highlights the wide variety of phenotypical characteristics in a Noonan syndrome patient, which was suspected upon birth and developed during the follow-up.

19.
Internist (Berl) ; 63(4): 448-452, 2022 Apr.
Article in German | MEDLINE | ID: mdl-35129621

ABSTRACT

BACKGROUND: Atrial septal defects (ASD) following endovascular mitral valve clipping are potentially hemodynamically relevant complications. Immediate closure with an occluder can represent a safe and effective treatment. An 81-year-old female patient suffering from severe dyspnea due to previously known severe mitral valve regurgitation was scheduled for elective mitral valve clipping. The clip was successfully implanted. Removal of the transseptal cannula resulted in a sudden drop in oxygen saturation and systolic blood pressure as well as an immediate increase in central venous pressure. An iatrogenic left-right shunt was observed at the atrial level with a relevant shunt volume. Immediate closure using an atrial septal occluder successfully restored the oxygen saturation and hemodynamic parameters. CONCLUSION: An increase in central venous pressure, reduction of systolic blood pressure or oxygen saturation after withdrawal of the transseptal cannula during mitral valve clipping should always be further investigated regarding a possible ASD.


Subject(s)
Mitral Valve Insufficiency , Mitral Valve , Aged, 80 and over , Blood Pressure , Cardiac Catheterization , Central Venous Pressure , Female , Humans , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/surgery , Oxygen Saturation
20.
Rev. bras. cir. cardiovasc ; 37(1): 48-54, Jan.-Feb. 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1365529

ABSTRACT

Abstract Introduction: The objective of this study is to evaluate the efficacy and midterm prognosis of transcatheter device closure of atrial septal defects (ASDs) in sexagenary patients in China. Methods: Forty-six sexagenary patients who underwent transcatheter device closure of ASDs in our hospital were included in this study. The patients' preoperative and postoperative clinical symptoms, echocardiographic results, and quality of life were investigated and analyzed. Results: Of the 46 sexagenary patients who participated in the study, 40 completed the study. After ASD closure, the clinical symptoms of the patients significantly improved, and the number of patients with dyspnea and palpitations significantly decreased after the operation. According to the echocardiographic results, few patients had a tiny residual shunt after closure, but the shunt disappeared completely at the three-month follow-up. The size of the right ventricular cavity was significantly smaller postoperatively compared with preoperatively. Regarding the patients' quality of life, their feedback in all dimensions of the 36-Item Short-Form Health Survey (or SF-36) was significantly improved at the three-month follow-up, and it remained improved at the one-year follow-up. Conclusion: The clinical outcomes and subjective quality of life of sexagenary patients with ASDs improved significantly after transcatheter device closure of ASDs. Therefore, we believe that for sexagenary patients with ASDs, transcatheter device closure is a favorable treatment.

SELECTION OF CITATIONS