Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters











Publication year range
1.
Int J Toxicol ; 42(3_suppl): 61S-73S, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37794531

ABSTRACT

The Expert Panel for Cosmetic Ingredient Safety reviewed newly available studies since their original assessment in 2005, along with updated information regarding product types and concentrations of use, and confirmed that these 22 methacrylate ester monomers are safe as used in nail enhancement products in the practices of use and concentration as described in this report, when skin contact is avoided.


Subject(s)
Cosmetics , Skin , Cosmetics/toxicity , Methacrylates/toxicity
2.
Article in Chinese | MEDLINE | ID: mdl-32892597

ABSTRACT

Objective: To establish a gas chromatography method for detecting isobutyl methacrylate in workplace air. Methods: From July to October 2019, isobutyl methacrylate in workplace air was collected by activated charcoal tube, absorbed using carbon disulfide and analyzed by gas chromatography (FID) with FFAP capillary column. Results: The linear range of isobutyl methacrylate in the method was 0-800 µg/ml, the correlation coefficient was 0.99993. The detection limit was 0.35 µg/ml. The lowest detected concentration was 0.12 mg/m(3). The within-run precision was 2.06%-2.72%, the between-run precision was 3.03%-3.83%. The rates of desorption was 96.7%. The breakthrough volume was 14.46 mg. The average sampling efficience was 100%. The samples could be stored at room temperature for 7 days. Conclusion: The method is simple, highly sensitive and precise. Isobutyl methacrylate in workplace air could be determined accurately.


Subject(s)
Air Pollutants, Occupational/analysis , Chromatography, Gas , Polymethacrylic Acids/analysis , Carbon Disulfide , Environmental Monitoring , Methacrylates , Workplace
3.
J Adv Prosthodont ; 7(2): 98-107, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25932307

ABSTRACT

PURPOSE: The aim of this study was to appraise the some mechanical properties of polymethyl methacrylate based denture base resin polymerized by copolymerization mechanism, and to investigate the cytotoxic effect of these copolymer resins. MATERIALS AND METHODS: 2-hydroxyethyl methacrylate (HEMA) and isobutyl methacrylate (IBMA) were added to monomers of conventional heat polymerized and injection-molded poly methyl methacrylate (PMMA) resin contents of 2%, 3%, and 5% by volume and polymerization was carried out. Three-point bending test was performed to detect flexural strength and the elasticity modulus of the resins. To determine the statistical differences between the study groups, the Kruskall-Wallis test was performed. Then pairwise comparisons were performed between significant groups by Mann-Whitney U test. Agar-overlay test was performed to determine cytotoxic effect of copolymer resins. Chemical analysis was determined by FTIR spectrum. RESULTS: Synthesis of the copolymer was approved by FTIR spectroscopy. Within the conventional heat-polymerized group maximum transverse strength had been seen in the HEMA 2% concentration; however, when the concentration ratio increased, the strength decreased. In the injection-molded group, maximum transverse strength had been seen in the IBMA 2% concentration; also as the concentration ratio increased, the strength decreased. Only IBMA showed no cytotoxic effect at low concentrations when both two polymerization methods applied while HEMA showed cytotoxic effect in the injection-molded resins. CONCLUSION: Within the limitations of this study, it may be concluded that IBMA and HEMA may be used in low concentration and at high temperature to obtain non-cytotoxic and durable copolymer structure.

4.
Article in English | WPRIM (Western Pacific) | ID: wpr-152480

ABSTRACT

PURPOSE: The aim of this study was to appraise the some mechanical properties of polymethyl methacrylate based denture base resin polymerized by copolymerization mechanism, and to investigate the cytotoxic effect of these copolymer resins. MATERIALS AND METHODS: 2-hydroxyethyl methacrylate (HEMA) and isobutyl methacrylate (IBMA) were added to monomers of conventional heat polymerized and injection-molded poly methyl methacrylate (PMMA) resin contents of 2%, 3%, and 5% by volume and polymerization was carried out. Three-point bending test was performed to detect flexural strength and the elasticity modulus of the resins. To determine the statistical differences between the study groups, the Kruskall-Wallis test was performed. Then pairwise comparisons were performed between significant groups by Mann-Whitney U test. Agar-overlay test was performed to determine cytotoxic effect of copolymer resins. Chemical analysis was determined by FTIR spectrum. RESULTS: Synthesis of the copolymer was approved by FTIR spectroscopy. Within the conventional heat-polymerized group maximum transverse strength had been seen in the HEMA 2% concentration; however, when the concentration ratio increased, the strength decreased. In the injection-molded group, maximum transverse strength had been seen in the IBMA 2% concentration; also as the concentration ratio increased, the strength decreased. Only IBMA showed no cytotoxic effect at low concentrations when both two polymerization methods applied while HEMA showed cytotoxic effect in the injection-molded resins. CONCLUSION: Within the limitations of this study, it may be concluded that IBMA and HEMA may be used in low concentration and at high temperature to obtain non-cytotoxic and durable copolymer structure.


Subject(s)
Denture Bases , Elastic Modulus , Hot Temperature , Polymerization , Polymers , Polymethyl Methacrylate , Spectroscopy, Fourier Transform Infrared , Spectrum Analysis
5.
J Adv Prosthodont ; 6(2): 121-5, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24843397

ABSTRACT

PURPOSE: The purpose of this study was to investigate the bonding properties of denture bases to silicone-based soft denture liners immersed in isobutyl methacrylate (iBMA) and 2-hydroxyethyl methacrylate (HEMA) for various lengths of time. MATERIALS AND METHODS: Polymethyl methacrylate (PMMA) test specimens were fabricated (75 mm in length, 12 mm in diameter at the thickest section, and 7 mm at the thinnest section) and then randomly assigned to five groups (n=15); untreated (Group 1), resilient liner immersed in iBMA for 1 minute (Group 2), resilient liner immersed in iBMA for 3 minutes (Group 3), resilient liner immersed in HEMA for 1 minute (Group 4), and resilient liner immersed in HEMA for 3 minutes (Group 5). The resilient liner specimens were processed between 2 PMMA blocks. Bonding strength of the liners to PMMA was compared by tensile test with a universal testing machine at a crosshead speed of 5 mm/min. Data were evaluated by 1-way ANOVA and post hoc Tukey-Kramer multiple comparisons tests (α=0.05). RESULTS: The highest mean value of force was observed in Group 3 specimens. The differences between groups were statistically significant (P<.05), except between Group 1 and Group 4 (P=.063). CONCLUSION: Immersion of silicone-based soft denture liners in iBMA for 3 minutes doubled the tensile bond strength between the silicone soft liner and PMMA denture base materials compared to the control group.

6.
Article in English | WPRIM (Western Pacific) | ID: wpr-55979

ABSTRACT

PURPOSE: The purpose of this study was to investigate the bonding properties of denture bases to silicone-based soft denture liners immersed in isobutyl methacrylate (iBMA) and 2-hydroxyethyl methacrylate (HEMA) for various lengths of time. MATERIALS AND METHODS: Polymethyl methacrylate (PMMA) test specimens were fabricated (75 mm in length, 12 mm in diameter at the thickest section, and 7 mm at the thinnest section) and then randomly assigned to five groups (n=15); untreated (Group 1), resilient liner immersed in iBMA for 1 minute (Group 2), resilient liner immersed in iBMA for 3 minutes (Group 3), resilient liner immersed in HEMA for 1 minute (Group 4), and resilient liner immersed in HEMA for 3 minutes (Group 5). The resilient liner specimens were processed between 2 PMMA blocks. Bonding strength of the liners to PMMA was compared by tensile test with a universal testing machine at a crosshead speed of 5 mm/min. Data were evaluated by 1-way ANOVA and post hoc Tukey-Kramer multiple comparisons tests (alpha=0.05). RESULTS: The highest mean value of force was observed in Group 3 specimens. The differences between groups were statistically significant (P<.05), except between Group 1 and Group 4 (P=.063). CONCLUSION: Immersion of silicone-based soft denture liners in iBMA for 3 minutes doubled the tensile bond strength between the silicone soft liner and PMMA denture base materials compared to the control group.


Subject(s)
Denture Bases , Denture Liners , Immersion , Polymethyl Methacrylate , Silicones
SELECTION OF CITATIONS
SEARCH DETAIL