Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters











Database
Language
Publication year range
1.
J Low Temp Phys ; 216(1-2): 57-66, 2024.
Article in English | MEDLINE | ID: mdl-39070765

ABSTRACT

Microwave Kinetic Inductance Detectors (MKIDs) are photon detectors comprised of superconducting LC resonators with unique resonant frequencies corresponding to their geometrical structure. As each pixel has its own geometry, electromagnetic simulations by hand of every pixel in a kilo-pixel array are impractical. Simulating fewer pixels and interpolating in between risks reduced pixel yield in arrays due to overlapping resonant frequencies. We introduce a new software called AEM (Automated Electromagnetic MKID simulations) that automates the construction and simulation of every simulated MKID pixel in an array according to specified resonant frequencies and a Q c range. We show automated designs to have an increased pixel yield (avoiding loses due to interpolation completely), increased accuracy in resonance frequency and Q c values when compared to interpolated structures. We also demonstrate a simulated trial of AEM for 100 MKIDs between 4 and 8 GHz to produce MKIDs with accuracies of ± 0.2 MHz with a runtime of 10 h 45 min.

2.
J Low Temp Phys ; 216(1-2): 408-416, 2024.
Article in English | MEDLINE | ID: mdl-39070767

ABSTRACT

Traditional technologies for far-infrared (FIR) spectroscopy generally involve bulky dispersive optics. Integrated filter bank spectrometers promise more compact designs, but implementations using superconducting transmission line networks become lossy at terahertz frequencies. We describe a novel on-chip spectrometer architecture designed to extend this range. A filter bank spectrometer is implemented using vacuum waveguide etched into a silicon wafer stack. A single trunk line feeds an array of resonant cavities, each coupled to a kinetic inductance detector fabricated on an adjacent wafer. We discuss the design and fabrication of a prototype implementation, initial test results at ambient temperature, and prospects for future development.

3.
J Low Temp Phys ; 216(1-2): 302-312, 2024.
Article in English | MEDLINE | ID: mdl-39070770

ABSTRACT

We report progress on the development of x-ray microcalorimeter thermal kinetic inductance detector (TKID) arrays, where each TKID is an independent pixel. Our goal in developing this detector technology is to arrive at high quantum efficiency, high fill factor, large-format, moderate energy resolution x-ray detector array which can be readily scaled to tens of kilo-pixels, to be used as an x-ray imaging spectrograph for astronomy and metrology applications. We discuss the evolution of the design, how it has been driven by fabrication related constraints, and the resulting impacts on detector performance.

4.
J Low Temp Phys ; 216(1-2): 144-153, 2024.
Article in English | MEDLINE | ID: mdl-39070766

ABSTRACT

Many superconducting on-chip filter-banks suffer from poor coupling to the detectors behind each filter. This is a problem intrinsic to the commonly used half-wavelength filter, which has a maximum theoretical coupling of 50 %. In this paper, we introduce a phase-coherent filter, called a directional filter, which has a theoretical coupling of 100 %. In order to study and compare different types of filter-banks, we first analyze the measured filter frequency scatter, losses, and spectral resolution of a DESHIMA 2.0 filter-bank chip. Based on measured fabrication tolerances and losses, we adapt the input parameters for our circuit simulations, quantitatively reproducing the measurements. We find that the frequency scatter is caused by nanometer-scale line width variations and that variances in the spectral resolution is caused by losses in the dielectric only. Finally, we include these realistic parameters in a full filter-bank model and simulate a wide range of spectral resolutions and oversampling values. For all cases, the directional filter-bank has significantly higher coupling to the detectors than the half-wave resonator filter-bank. The directional filter eliminates the need to use oversampling as a method to improve the total efficiency, instead capturing nearly all the power remaining after dielectric losses.

5.
J Low Temp Phys ; 193(3-4)2018.
Article in English | MEDLINE | ID: mdl-34815585

ABSTRACT

Microwave Kinetic Inductance Detectors (MKIDs) provide a compelling path forward to the large-format polarimeter, imaging, and spectrometer arrays needed for next-generation experiments in millimeter-wave cosmology and astronomy. We describe the development of feedhorn-coupled MKID detectors for the TolTEC millimeter-wave imaging polarimeter being constructed for the 50-meter Large Millimeter Telescope (LMT). Observations with TolTEC are planned to begin in early 2019. TolTEC will comprise ∼7,000 polarization sensitive MKIDs and will represent the first MKID arrays fabricated and deployed on monolithic 150 mm diameter silicon wafers - a critical step towards future large-scale experiments with over 105 detectors. TolTEC will operate in observational bands at 1.1, 1.4, and 2.0 mm and will use dichroic filters to define a physically independent focal plane for each passband, thus allowing the polarimeters to use simple, direct-absorption inductive structures that are impedance matched to incident radiation. This work is part of a larger program at NIST-Boulder to develop MKID-based detector technologies for use over a wide range of photon energies spanning millimeter-waves to X-rays. We present the detailed pixel layout and describe the methods, tools, and flexible design parameters that allow this solution to be optimized for use anywhere in the millimeter and sub-millimeter bands. We also present measurements of prototype devices operating in the 1.1 mm band and compare the observed optical performance to that predicted from models and simulations.

SELECTION OF CITATIONS
SEARCH DETAIL