Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Front Genet ; 13: 865472, 2022.
Article in English | MEDLINE | ID: mdl-35846122

ABSTRACT

Breast cancer (BC) is a heterogeneous disease, and establishing biomarkers is essential to patient management. We previously described that extracellular vesicle-derived miRNAs (EV-miRNAs) miR-142-5p, miR-150-5p, miR-320a, and miR-4433b-5p in serum discriminated BC from control samples, either alone or combined in a panel. Using these previously described markers, we intend to evaluate whether the same markers identified in EVs are also potential biomarkers in tissue and serum. Expression analysis using RT-qPCR was performed using serum of 67 breast cancer patients (BC-S), 19 serum controls (CT), 83 fresh tumor tissues (BC-T), and 29 adjacent nontumor tissue samples (NT). In addition, analysis from The Cancer Genome Atlas (TCGA) data (832 BC-T and 136 NT) was performed. In all comparisons, we found concordant high expression levels of miR-320a and miR-4433b-5p in BC-S compared to CT in both EVs and cell-free miRNAs (cf-miRNAs). Although miR-150-5p and miR-142-5p were not found to be differentially expressed in serum, panels including these miRNAs improved sensitivity and specificity, supporting our previous findings in EVs. Fresh tissue and data from the TCGA database had, in most comparisons, an opposite behavior when compared to serum and EVs: lower levels of all miRNAs in BC-T than those in NT samples. TCGA analyses revealed reduced expression levels of miR-150-5p and miR-320a-3p in BC-T than those in NT samples and the overexpression of miR-142-5p in BC-T, unlike our RT-qPCR results from tissue in the Brazilian cohort. The fresh tissue analysis showed that all miRNAs individually could discriminate between BC-T and NT in the Brazilian cohort, with high sensitivity and sensibility. Furthermore, combining panels showed higher AUC values and improved sensitivity and specificity. In addition, lower levels of miR-320a-3p in serum were associated with poor overall survival in BC Brazilian patients. In summary, we observed that miR-320a and miR-4433b-5p distinguished BC from controls with high specificity and sensibility, regardless of the sample source. In addition, lower levels of miR-150-5p and higher levels of miR-142-5p were statistically significant biomarkers in tissue, according to TCGA. When combined in panels, all combinations could distinguish BC patients from controls. These results highlight a potential application of these miRNAs as BC biomarkers.

2.
Curr Issues Mol Biol ; 44(5): 1838-1850, 2022 Apr 22.
Article in English | MEDLINE | ID: mdl-35678655

ABSTRACT

Our research group, through the analysis of miRNomes in platelet concentrates (PCs) stored in blood banks, identified and validated the miR-127 and miR-320a miRNAs as biomarkers of platelet storage lesions (PSLs) in PCs. In order to validate the miRNAs 127 and 320a methodologically, as PSL biomarkers in a large number of PC bags, we also evaluated important immunological markers involved in the platelet activation/aggregation process-the CD62P receptor (P-selectin), the surface glycoproteins (GP) IIb/IIIa, and the purinergic P2Y12 receptor-via flow cytometry. The miRNAs miR-127 and miR-320a were quantified by real-time quantitative PCR (RT-qPCR). To carry out this study, 500 collection tubes were used at the upper edge of the PC bags containing platelets. Each tube was divided into seven equal parts (totaling 3500 samples) for platelet analysis from 7 different storage days, where the 1st day represents the high-quality control, and the 7th day corresponds to the low-quality control of the platelets. After analyzing all parameters during storage days, it was concluded that the relative quantification of miR-320a below 0.50 and the CD62P receptor below 27.92% are reliable indicators of the absence of storage lesions in blood banks. We believe that the values found in the expression of the CD62P receptor legitimize the use of the miR-320a and miR-127 miRNAs to build a kit capable of accurately measuring whether the stored platelets are suitable for transfusion.

SELECTION OF CITATIONS
SEARCH DETAIL