Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 137
Filter
1.
Circulation ; 150(8): e183-e196, 2024 Aug 20.
Article in English | MEDLINE | ID: mdl-38984417

ABSTRACT

The rapid technological advancements in cardiac implantable electronic devices such as pacemakers, implantable cardioverter defibrillators, and loop recorders, coupled with a rise in the number of patients with these devices, necessitate an updated clinical framework for periprocedural management. The introduction of leadless pacemakers, subcutaneous and extravascular defibrillators, and novel device communication protocols underscores the imperative for clinical updates. This scientific statement provides an inclusive framework for the periprocedural management of patients with these devices, encompassing the planning phase, procedure, and subsequent care coordinated with the primary device managing clinic. Expert contributions from anesthesiologists, cardiac electrophysiologists, and cardiac nurses are consolidated to appraise current evidence, offer patient and health system management strategies, and highlight key areas for future research. The statement, pertinent to a wide range of health care professionals, underscores the importance of quality care pathways for patient safety, optimal device function, and minimization of hemodynamic disturbances or arrhythmias during procedures. Our primary objective is to deliver quality care to the expanding patient cohort with cardiac implanted electronic devices, offering direction in the era of evolving technologies and laying a foundation for sustained education and practice enhancement.


Subject(s)
American Heart Association , Defibrillators, Implantable , Pacemaker, Artificial , Perioperative Care , Humans , Defibrillators, Implantable/standards , United States , Perioperative Care/standards , Perioperative Care/methods , Patient Care Team , Arrhythmias, Cardiac/therapy
2.
Open Heart ; 11(1)2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38890128

ABSTRACT

BACKGROUND: Neurocardiogenic syncope is a common condition with significant associated psychological and physical morbidity. The effectiveness of therapeutic options for neurocardiogenic syncope beyond placebo remains uncertain. METHODS: The primary endpoint was the risk ratio (RR) of spontaneously recurring syncope following any therapeutic intervention. We also examined the effect of blinding on treatment efficacy. We identified all randomised trials which evaluated the effect of any pharmacological, device-based or supportive intervention on patients with a history of syncope. A systematic search was conducted on Medline, Embase, PubMed databases and Cochrane Central Register for Controlled Trials from 1950 to 25 April 2023. Event rates, their RRs and 95% CIs were calculated, and a random-effects meta-analysis was conducted for each intervention. Data analysis was performed in R using RStudio. RESULTS: We identified 47 eligible trials randomising 3518 patients. Blinded trials assessing syncope recurrence were neutral for beta blockers, fludrocortisone and conventional dual-chamber pacing but were favourable for selective serotonin reuptake inhibitors (SSRIs) (RR 0.40, 95% CI 0.26 to 0.63, p<0.001), midodrine (RR 0.70, 95% CI 0.53 to 0.94, p=0.016) and closed-loop stimulation (CLS) pacing (RR 0.15, 95% CI 0.07 to 0.35, p<0.001). Unblinded trials reported significant benefits for all therapy categories other than beta blockers and consistently showed larger benefits than blinded trials. CONCLUSIONS: Under blinded conditions, SSRIs, midodrine and CLS pacing significantly reduced syncope recurrence. Future trials for syncope should be blinded to avoid overestimating treatment effects. PROSPERO REGISTRATION NUMBER: CRD42022330148.


Subject(s)
Randomized Controlled Trials as Topic , Syncope, Vasovagal , Humans , Syncope, Vasovagal/therapy , Syncope, Vasovagal/diagnosis , Randomized Controlled Trials as Topic/methods , Treatment Outcome , Recurrence
4.
Tex Heart Inst J ; 51(1)2024 04 02.
Article in English | MEDLINE | ID: mdl-38564374

ABSTRACT

This report discusses a case of transient 2:1 atrioventricular block with conduction system pacing 4 hours after leadless right ventricular pacemaker implantation in a 19-year-old patient with a history of cardioinhibitory syncope and asystole cardiac arrest but without preexisting atrioventricular block. The atrioventricular block was resolved spontaneously. Pacing morphology was suggestive of right bundle branch pacing. Neither 2:1 atrioventricular block nor conduction system pacing has previously been a reported outcome of right ventricular leadless pacemaker implantation. The report demonstrates that conduction system pacing with leadless devices is achievable. Further study of techniques, limitations, and complications related to intentional right ventricular leadless conduction system pacing is warranted.


Subject(s)
Atrioventricular Block , Pacemaker, Artificial , Humans , Young Adult , Adult , Atrioventricular Block/diagnosis , Atrioventricular Block/therapy , Atrioventricular Block/etiology , Cardiac Pacing, Artificial/methods , Pacemaker, Artificial/adverse effects , Heart Conduction System , Heart Ventricles , Treatment Outcome
5.
Open Heart ; 11(1)2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38538064

ABSTRACT

OBJECTIVE: Transthyretin amyloid cardiomyopathy (ATTR-CM) is an infiltrative cardiac disorder caused by deposition of wild type or mutated transthyretin. As ATTR-CM is associated with conduction disease, we sought to determine its prevalence in patients with idiopathic high-degree atrioventricular (AV) block requiring permanent pacemaker (PPM) implantation. METHODS: Consecutive patients aged 70-85 years undergoing PPM implantation for idiopathic high-degree AV block between November 2019 and November 2021 were offered a 3,3-diphosphono-1,2-propanodicarboxylic acid (DPD) scan. Demographics, comorbidities, electrocardiographic and imaging data from the time of device implantation were retrospectively collected. RESULTS: 39 patients (79.5% male, mean (SD) age at device implantation 76.2 (2.9) years) had a DPD scan. 3/39 (7.7%, all male) had a result consistent with ATTR-CM (Perugini grade 2 or 3). Mean (SD) maximum wall thickness of those with a positive DPD scan was 19.0 mm (3.6 mm) vs 11.4 mm (2.7 mm) in those with a negative scan (p=0.06). All patients diagnosed with ATTR-CM had spinal canal stenosis and two had carpal tunnel syndrome. CONCLUSIONS: ATTR-CM should be considered in older patients requiring permanent pacing for high-degree AV block, particularly in the presence of left ventricular hypertrophy, carpal tunnel syndrome or spinal canal stenosis.


Subject(s)
Amyloidosis , Atrioventricular Block , Carpal Tunnel Syndrome , Humans , Male , Aged , Female , Atrioventricular Block/diagnosis , Atrioventricular Block/epidemiology , Atrioventricular Block/therapy , Retrospective Studies , Prevalence , Prealbumin , Carpal Tunnel Syndrome/complications , Constriction, Pathologic/complications
6.
Circ Cardiovasc Interv ; 17(2): e013094, 2024 02.
Article in English | MEDLINE | ID: mdl-38152879

ABSTRACT

BACKGROUND: A high permanent pacemaker implantation (PPI) risk remains a concern of self-expandable transcatheter aortic valve implantation, despite the continued improvements in implantation methodology. We aimed to assess the impact of real-time direct visualization of the membranous septum using transjugular intracardiac echocardiography (ICE) during transcatheter aortic valve implantation on reducing the rates of conduction disturbances including the need for PPI. METHODS: Consecutive patients treated with Evolut R and Evolut PRO/PRO+ from February 2017 to September 2022 were included in this study. We compared outcomes between the conventional implantation method using the 3-cusps view (3 cusps without ICE group), the recent method using cusp-overlap view (cusp overlap without ICE group), and our novel method using ICE (cusp overlap with ICE group). RESULTS: Of the 446 patients eligible for analysis, 211 (47.3%) were categorized as the 3 cusps without ICE group, 129 (28.9%) were in the cusp overlap without ICE group, and 106 (23.8%) comprised the cusp overlap with ICE group. Compared with the 3 cusps without ICE group, the cusp overlap without ICE group had a smaller implantation depth (2.2 [interquartile range, 1.0-3.5] mm versus 4.3 [interquartile range, 3.3-5.4] mm; P<0.001) and lower 30-day PPI rates (7.0% versus 14.2%; P=0.035). Compared with the cusp overlap without ICE group, the cusp overlap with ICE group had lower 30-day PPI rates (0.9%; P=0.014), albeit with comparable implantation depths (1.9 [interquartile range, 0.9-2.9] mm; P=0.150). Multivariable analysis showed that our novel method using ICE with the cusp-overlap view was independently associated with a 30-day PPI rate reduction. There were no group differences in 30-day all-cause mortality (1.4% versus 1.6% versus 0%; P=0.608). CONCLUSIONS: Our novel implantation method using transjugular ICE, which enable real-time direct visualization of the membranous septum, achieved a predictably high position of prostheses, resulting in a substantial reduction of conduction disturbances requiring PPI after transcatheter aortic valve implantation.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Cardiac Pacing, Artificial/adverse effects , Risk Factors , Treatment Outcome , Echocardiography
7.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1024446

ABSTRACT

Objective To compare patient radiation dose during implantation of the second generation wireless pacemaker(Micra AV)and traditional dual-chamber pacemaker.Methods Data of 74 patients who received pacemaker implantation for bradycardia were retrospectively analyzed.According to the kind of pacemaker,the patients were divided into AV group(n=30)and traditional group(n=44).The perspective time,air kerma(AK),dose area product(DAP),number of movie sequences and total movie frames were compared between groups.Results AK,movie DAP,number of movie sequence and total movie frames in AV group were all higher than those in traditional group(all P<0.05).No significant difference of the perspective time nor perspective DAP was found between groups(both P>0.05).Patients'X-ray radiation projection range were essentially the same in both groups,most distributing on the left side of the bodies.Conclusion Compared with implantation of traditional dual-chamber pacemaker,implantation of Micra AV brought patient greater radiation dose from movie acquisition,while radiation dose from fluoroscopy were not significantly different.

8.
Open Heart ; 10(2)2023 Dec 14.
Article in English | MEDLINE | ID: mdl-38097364

ABSTRACT

INTRODUCTION: Use of the mechanically expandable transcatheter aortic valve (MEV) has been recently linked to increased risks of valve dysfunction and cardiovascular mortality. The risk of developing conduction disturbance with the MEV valve is well known, and the negative prognostic impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation is another consideration. AIM: This study aimed to compare the mid-term survival of patients with MEV and self-expandable valves (SEV), and to examine survival of both groups according to the presence or absence of PPI. METHODS: This single-centre, retrospective, observational study examined data from MEV and SEV groups comprising 92 and 373 patients, respectively. The mean clinical follow-up was 2.5±1.7 years. Mortality information was obtained from the National Institutes of Health Information and Statistics. RESULTS: Baseline characteristics were comparable between the groups. The log-rank test showed higher cardiovascular mortality in the MEV group (p=0.042; the relative risk (RR) 1.594 (95% CI 1.013 to 2.508)). The Cox proportional hazards model identified MEV implantation as an independent predictor of cardiovascular mortality. The rate of PPI was twice as high in the MEV vs SEV group (33.7% vs 16.1%; p<0.001). We compared the survival of both groups according to the presence or absence of PPI and found higher mortality in the MEV group without PPI versus the SEV group without PPI (p=0.007; RR 2.156 (95% CI 1.213 to 3.831)). Survival did not differ in the groups with PPI. CONCLUSIONS: A higher mid-term cardiovascular mortality rate was observed with MEV versus SEV implants. Comparing both groups according to the presence or absence of PPI, we observed a higher mortality risk in patients with MEV without PPI than in SEV without PPI. In contrast, mortality did not differ between the groups when PPI was implanted.


Subject(s)
Aortic Valve Stenosis , Pacemaker, Artificial , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Retrospective Studies , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Risk Factors
9.
Arq. bras. cardiol ; 120(2): e20210941, 2023. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1420185

ABSTRACT

Resumo Há uma enorme disparidade entre os países de alta renda e outros em termos de acesso a dispositivos médicos cardíacos, como marca-passos e desfibriladores implantáveis. Os custos são uma das principais barreiras ao uso de dispositivos cardíacos nesses países. Existem iniciativas internacionais que visam reduzir essa disparidade, e o reuso de marca-passos tem sido discutido como uma possível alternativa. O conceito de reutilização de marca-passos não é novo; entretanto, estudos recentes têm se mostrado seguros, éticos e eficazes para aqueles que precisam de dispositivos eletrônicos cardíacos implantáveis e não tem como adquiri-los. Parte dos países de língua portuguesa, especialmente na África, precisam de uma resposta imediata que beneficie seus inúmeros pacientes que sofrem de arritmias tratáveis.


Abstract There is a gap between high-income countries and others in terms of access to medical cardiac devices, such as pacemakers and implantable cardioverter defibrillators. Costs are one of the main barriers to the use of cardiac devices in these countries. There are international initiatives that aim to reduce the gap. The reuse of pacemakers has been discussed as a possible alternative to this problem. The concept of reusing pacemakers is not new; however, recent studies have proven to be safe, ethical, and effective for those who need cardiac implantable electronic devices and cannot afford them. Part of the Portuguese-speaking countries, especially in Africa, need an immediate response that benefits their countless patients who suffer from treatable arrhythmias.

10.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-990310

ABSTRACT

Objective:To study the application value of nursing management based on self-efficacy theory in the early functional exercise of the affected limb after permanent pacemaker implantation.Methods:This study was a randomized controlled trial. A total of 90 patients who underwent permanent pacemaker implantation in Wuxi Second People′s Hospital (the Affiliated Central Hospital of Jiangnan University) from May 2019 to March 2021 were enrolled. They were divided into observation group and control group with 45 patients each according to random number table. The control group received routine nursing intervention, and the observation group received supplemental management interventions based on self-efficacy theory. The rate of post-operative rehabilitation up to the standard, the scores of the Shoulder Pain and Disability Index (SPADI), Chronic Disease Self-Efficacy Scale (CDSES) and Quality of Life Instrument for Patients with Pacemaker (QLIPP) were compared.Results:The rate of observation group's post-operative rehabilitation up to the standard was 93.33% (42/45), which was higher than that of the control group 77.78% (35/45). The difference was statistically significant ( χ2 =4.41, P<0.05). The pain index of the observation group was (20.27 ± 4.13), (5.25 ± 2.64)points at 1 and 2 weeks after operation, which was significantly lower than (27.06 ± 5.30), (9.35 ± 4.22) points of the control group ( t=6.78, 5.53, both P<0.05). The dysfunction index of the observation group was (15.06 ± 5.96), (7.21 ± 3.68) points, which was significantly lower than (17.75 ± 6.04), (9.03 ± 4.06) points of the control group ( t=2.13, 2.23, both P<0.05). After 2 weeks of operation, the total score of CDSES in the observation group was (4.73 ± 1.68) points, which was higher than (3.67 ± 1.49) points in the control group, and the difference was statistically significant ( t=3.17, P<0.05). The total score of QLIPP in the observation group was (92.78 ± 6.26), (124.40 ± 4.91) points at 2 weeks and 1 month after operation, which was significantly higher than (83.50 ± 7.91), (112.42 ± 5.04) points in the control group ( t=6.17, 9.51, both P<0.05). Conclusions:The application of nursing care based on self-efficacy theory in the patients of early functional exercise of the affected limb after permanent pacemaker implantation can improve rehabilitation compliance, self-efficacy of patients, the function of the affected shoulder joint and the patient′s quality of life.

11.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-994726

ABSTRACT

Objective:To evaluate the safety of leadless pacemaker implantation in super-elderly patients.Methods:Eleven patients with average age of 90 (86, 92) years who underwent leadless pacemaker implantation in the Department of Cardiology, Peking University People′s Hospital from March 2021 to May 2022 were included. The clinical data and implantation information were collected. The complications (cardiac tamponade, myocardial infarction, cerebral infarction, pulmonary embolism, pacemaker reinfection, femoral vein hematoma) and death of patients were documented at 24 h, 3 d, and 1, 3, 6 months after pacemaker implantation.Results:There were 9 males and 2 females with the body mass index of 21(19, 23)kg/m 2. The underlying diseases were hypertension, diabetes, coronary heart disease, chronic kidney disease, chronic obstructive pulmonary disease, previous cerebral infarction and moderate to severe tricuspid regurgitation in 9, 9, 9, 6, 4, 4, 4 patients, respectively. The left ventricular ejection fraction was 49% (45%, 52%), the hemoglobin concentration was 118 (114, 122)g/L, 4 patients were taking anticoagulant drugs, and 6 patients were taking antiplatelet drugs. Eight patients were newly implanted with a leadless pacemaker, 2 patients were implanted after removal the old ones, and 1 case was implanted at the same time as removal. The implantation time was 45(40, 47) minutes, the X-ray exposure time was 14 (13, 15) minutes, the release time was 1 (1, 2), the threshold value was 0.50(0.38, 0.75)V/0.24 ms, the impedance was 730 (700, 770) Ω, and the perceived R-wave amplitude 8.2(6.7, 12.8) mV. During the follow-up period of 8 (6, 10) months, no patient had pacemaker dysfunction; and the threshold, R wave sensing, and impedance were stable and maintained within the normal range. No cardiac tamponade, myocardial infarction, cerebral infarction, pulmonary embolism, pacemaker reinfection or death occurred perioperatively and during the follow-up period; 1 patient had hematoma after femoral vein puncture, which improved after compression treatment. Conclusion:This single-center and small-sample study shows that leadless pacemaker implantation is safe for super-elderly patients.

13.
Arq. bras. cardiol ; 119(6): 902-909, dez. 2022. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1420139

ABSTRACT

Resumo Fundamento A síndrome do PRKAG2 é uma doença hereditária autossômica dominante rara, de início precoce. Objetivamos descrever os achados ecocardiográficos do ventrículo direito (VD) usando modalidades bi e tridimensionais (2D e 3D), incluindo índices de deformação miocárdica nesta cardiomiopatia. Também objetivamos demonstrar se esta técnica poderia identificar alterações na função do VD que pudessem distinguir quaisquer achados particulares. Métodos Trinta pacientes com síndrome do PRKAG2 (R302Q e H401Q) geneticamente comprovada, 16 (53,3%) do sexo masculino, com idade média de 39,1 ± 15,4 anos, foram submetidos a exame ecocardiográfico completo. A visão de 4 câmaras com foco no VD foi adquirida para medições 2D e 3D. Os testes t de Student ou Wilcoxon-Mann-Whitney foram usados para comparar as variáveis numéricas entre 2 grupos, e p < 0,05 foi considerado significativo. Resultados Doze pacientes (40%) tiveram marca-passo implantado por 12,4 ± 9,9 anos. A espessura diastólica média da parede livre do VD foi de 7,9 ± 2,9 mm. O strain longitudinal de 4 câmaras do VD (SL4VD), incluindo a parede livre e o septo interventricular, foi de -17,3% ± 6,7%, e o strain longitudinal da parede livre do VD (SLPLVD) foi de −19,1% ± 8,5%. A razão apical do SLPLVD mediu 0,63 ± 0,15. A fração de ejeção (FE) 3D média do VD foi de 42,6% ± 10,9% e abaixo dos limites normais em 56,7% dos pacientes. Correlação positiva ocorreu entre FE 3D do VD, SL4VD e SLPLVD, principalmente para pacientes sem marca-passo (p = 0,006). Conclusão O envolvimento do VD em PRKAG2 é frequente e ocorre em diferentes graus. A ecocardiografia é uma ferramenta valiosa na detecção de anormalidades miocárdicas do VD nesta condição. O uso de SL4VD 2D, SLPLVD e FE 3D oferecem indicadores confiáveis de disfunção sistólica do VD nesta cardiomiopatia rara e desafiadora.


Abstract Background PRKAG2 syndrome is a rare, early-onset autosomal dominant inherited disease. We aimed to describe the right ventricle (RV) echocardiographic findings using two and three-dimensional (2D and 3D) modalities including myocardial deformation indices in this cardiomyopathy. We also aimed to demonstrate whether this technique could identify changes in RV function that could distinguish any particular findings. Methods Thirty patients with genetically proven PRKAG2 (R302Q and H401Q), 16 (53.3%) males, mean age 39.1 ± 15.4 years, underwent complete echocardiography examination. RV-focused, 4-chamber view was acquired for 2D and 3D measurements. Student's t or Wilcoxon-Mann-Whitney tests were used to compare numerical variables between 2 groups, and p < 0.05 was considered significant. Results Twelve patients (40%) had a pacemaker implanted for 12.4 ± 9.9 years. RV free wall mean diastolic thickness was 7.9 ± 2.9 mm. RV 4-chamber longitudinal strain (RV4LS), including the free wall and interventricular septum, was -17.3% ± 6.7%, and RV free wall longitudinal strain (RVFWLS) was −19.1% ± 8.5%. The RVFWLS apical ratio measured 0.63 ± 0.15. Mean RV 3D ejection fraction (EF) was 42.6% ± 10.9% and below normal limits in 56.7% of patients. Positive correlation occurred between RV 3DEF, RV4LS, and RVFWLS, especially for patients without a pacemaker (p = 0.006). Conclusion RV involvement in PRKAG2 syndrome is frequent, occurring in different degrees. Echocardiography is a valuable tool in detecting RV myocardial abnormalities in this condition. The use of 2D RV4LS, RVFWLS, and 3DEF offers reliable indicators of RV systolic dysfunction in this rare, challenging cardiomyopathy.

14.
Nursing ; 25(294): 8954-8969, nov.2022.
Article in English, Portuguese | LILACS, BDENF - Nursing | ID: biblio-1402600

ABSTRACT

Objetivo:Identificar o perfil dos pacientes submetidos à inserção de dispositivos cardíacos eletrônicos implantáveis em um hospital de referência do Rio Grande do Norte.Método:Trata-se de um estudo descritivo, exploratório, retrospectivo dos últimos 03 anoscom abordagem quantitativa. Amostragem foiselecionada por conveniência. A coleta de dados ocorreu entre outubrode 2017 a março de 2018.Resultados: A amostra foi composta por 215prontuários,destes 182 foram analisados.Implantarammarca-passos63,7% e 28% cardiodesfibriladores, corresponderam ao sexo masculino69,3%,com média de idade 65 e 49.Entre as comorbidades,a Hipertensão Arterial Sistêmicaabrangeu 87,4%.Evidenciaram-se os bloqueios atrioventriculares como principal causa para implantes (35%), seguidos das miocardiopatias (12%).Conclusão:Percebeu-se que, os indivíduos que implantaram marcapassos eram acometidos por bradiarritmias,enquanto cardiodesfibriladores por taquiarritmias. As complicações pós-operatórias e intercorrências durante o procedimento foram de baixo risco. Salienta-se, que no manejo desses usuários é fundamental a elaboração de um protocolo, visando aperfeiçoar o cuidado.(AU)


Objective: Toidentifytheprofileofpatientsundergoinginsertionof implantable electroniccardiacdevices in a reference hospital in Rio Grande do Norte. Method: Thisis a descriptive, exploratory,retrospective studyofthelastthreeyearswith a quantitativeapproach. Samplingwasselectedby convenience. Data collectionoccurredbetweenOctober 2017 to March 2018. Results: Samplecomposedof 215 medical records, ofthese 182 wereanalyzed. Implantedpacemakers 63.7% and 28% cardiodesfibrillators, corresponded tothe male gender 69.3%, withaverageage 65 and 49. Amongthecomorbidities, Systemic Arterial Hypertensioncovered 87.4%. Theatrioventricular blocks wereevidenced as themain cause forimplantation (35%), followedbymyocardiopathies (12%). Conclusion: Itwasnoticedthatindividualswhoimplantedpacemakerswereaffectedbybradyarrhythmias, whilecardioverter-defibrillatorswereaffe ctedbytachyarrhythmias. Thepostoperativecomplications and complicationsduringtheprocedurewerelowrisk. Itisemphasizedthat in themanagementoftheseusersitisessentialtodevelop a protocol, aimingtoimprove care.(AU)


Objetivo: identificar el perfil de los pacientes sometidos a la inserción de dispositivos cardíacos electrónicos implantables en el hospital de referencia de Rio Grande do Norte. Método: se trata de un estudio descriptivo, exploratorio, retrospectivo de los últimos 3 años con enfoque cuantitativo. El muestreo fue seleccionado por conveniencia. La recolección de datos se llevó a cabo entre octubre de 2017 y marzo de 2018. Resultados: muestra compuesta por 215 historias clínicas, de las cuales se analizaron 182. Marcapasos implantados 63,7% y desfibriladores cardioversores 28%, correspondieron al sexo masculino 69,3%, con una edad media de 65 y 49 años. Entre las comorbilidades, la Hipertensión Arterial Sistémica cubrió el 87,4%. Los bloqueos auriculoventriculares se evidenciaron como la principal causa de implantes (35%), seguida de las miocardiopatías (12%). Conclusión: se notó que, los portadores de marcapasos se vieron afectados por bradiarritmias, mientras que los desfibriladores cardioversores por taquiarritmias. Las complicaciones postoperatorias y las complicaciones durante el procedimiento fueron de bajo riesgo. Cabe señalar que en el manejo de estos usuarios es fundamental la elaboración de un protocolo, con el fin de mejorar la atención.(AU)


Subject(s)
Pacemaker, Artificial , Arrhythmias, Cardiac , Surgical Procedures, Operative , Cardiology , Defibrillators, Implantable
15.
Arq. bras. cardiol ; 119(4): 522-530, Oct. 2022. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1403353

ABSTRACT

Resumo Fundamento Os distúrbios de condução (DC) são a complicação mais frequente após a substituição da válvula aórtica transcateter (TAVR) e ainda não há consenso sobre seu tratamento. Objetivo Avaliar novos DC e implante de marca-passo definitivo (MPD) após a TAVR e avaliar a porcentagem de estimulação ventricular (EV) até 1 ano de acompanhamento. Métodos Pacientes submetidos a TAVR de outubro de 2014 a novembro de 2019 foram cadastrados; pacientes com MPD anterior foram excluídos. Dados clínicos, do procedimento, do ECG e do MPD foram coletados até 1 ano após o implante. O nível de significância adotado para a análise estatística foi 0,05%. Resultados Um total de 340 indivíduos foram submetidos a TAVR. O DC mais comum foi bloqueio de ramo esquerdo novo (BRE; 32,2%), sendo que 56% destes foram resolvidos após 6 meses. O bloqueio do ramo direito (BRD) foi o maior fator de risco para bloqueio atrioventricular avançado (BAV) [RC=8,46; p<0,001] e implante de MPD [RC=5,18; p<0,001], seguido de BAV de baixo grau prévio [RC=2,25; p=0,016 para implante de MPD]. Em relação às características do procedimento, válvulas de gerações mais recentes e procedimentos de válvula-em-válvula foram associados a menos DC. No total, 18,5% dos pacientes tiveram MPD implantado após a TAVR. Na primeira avaliação do MPD, pacientes com BAV avançado tinham uma porcentagem mediana de EV de 80%, e, após um ano, de 83%. Em relação aos pacientes com BRE e BAV de baixo grau, a EV mediana foi mais baixa (6% na primeira avaliação, p=0,036; 2% após um ano, p = 0,065). Conclusão O BRE foi o DC mais frequente após a TAVR, com mais da metade dos casos se resolvendo nos primeiros 6 meses. O BRD foi o principal fator de risco para BAV avançado e implante de MPD. O BAV avançado foi associado a uma porcentagem mais alta de EV no acompanhamento de 1 ano.


Abstract Background Conduction disturbances (CD) are the most frequent complication after transcatheter aortic valve replacement (TAVR), and there continues to be a lack of consensus on their management. Objective To assess new CD and permanent pacemaker (PPM) implantation after TAVR and to evaluate the ventricular pacing percentage (VP) up to 1 year of follow-up. Methods Patients who underwent TAVR from October 2014 to November 2019 were enrolled; patients with previous PPM were excluded. Clinical, procedure, ECG, and PPM data were collected up to 1 year after implantation. The significance level adopted in the statistical analysis was 0.05. Results A total of 340 patients underwent TAVR. The most frequent CD was the new left bundle branch block (LBBB; 32.2%), which 56% resolved after 6 months. Right bundle branch block (RBBB) was the biggest risk factor for advanced atrioventricular block (AVB) [OR=8.46; p<0.001] and PPM implantation [OR=5.18, p<0.001], followed by previous low-grade AVB [OR=2.25; p=0.016 for PPM implantation]. Regarding procedure characteristics, newer generation valves and valve-in-valve procedures were associated with fewer CDs. Overall, 18.5% of patients had a PPM implanted post-TAVR. At first PPM evaluation, patients with advanced AVB had a median percentage of VP of 80% and 83% at one year. Regarding patients with LBBB plus low-grade AVB, median VP was lower (6% at first assessment, p=0.036; 2% at one year, p = 0.065). Conclusion LBBB was the most frequent CD after TAVR, with more than half being resolved in the first six months. RBBB was the major risk factor for advanced AVB and PPM implantation. Advanced AVB was associated with a higher percentage of VP at 1 year of follow-up.

17.
Einstein (Säo Paulo) ; 20: eAO8013, 2022. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1384792

ABSTRACT

ABSTRACT Objective To determine the rate of complications associated with the use of temporary pacemakers in patients in the waiting list for the definitive pacemaker implantation in a public hospital located in São Paulo, SP, Brazil. Methods Retrospective observational study based on data extracted from medical records of patients admitted to Hospital Municipal Dr. Moyses Deutsch, Hospital Israelita Albert Einstein from January 2014 to December 2018. Patients aged 18 years or older, diagnosed with high degree atrioventricular block upon admission and with indications for definitive pacemaker implantation were included. All-cause mortality, clinical and surgical complications and length of hospital stay while waiting for the procedure were defined as primary outcomes. Results The sample comprised 66 patient allocated to one of two groups: with and without the need of temporary pacemaker while in hospital (n=45 and n=21, respectively). The rate of complications was higher in patients who used a temporary pacemaker (p<0.001). These included primarily pneumonia (p=0.048) and length of hospital stay (p=0.029). Conclusion Patients who required a temporary pacemaker stayed longer in hospital. Longer hospital stay is associated with higher rates of general complications and all-cause mortality.

18.
Rev. bras. enferm ; 75(supl.4): e20210192, 2022. tab
Article in English | LILACS-Express | LILACS, BDENF - Nursing | ID: biblio-1351726

ABSTRACT

ABSTRACT Objective: to understand how the transitional care of nurses to olde adults with artificial pacemaker occurs. Method: a qualitative research, carried out in a philanthropic hospital in the city of Salvador, Bahia, Brazil. Fourteen nurses working in surgical and cardiac inpatient units participated. Data were collected between August and November 2020, through semi-structured interviews, and analyzed using the methodological framework Discourse of the Collective Subject and discussed in the light of Afaf Meleis' theory of transitions. Results: nurses' incipient knowledge about transitional care was identified. It was observed that the nursing discharge report is a facilitating instrument for transitional care. Final considerations: the study pointed out that the transitional care of nurses to older adults with artificial pacemakers does not have a theoretical foundation, reporting as a priority the care with the pacemaker identification card and with the surgical wound.


RESUMEN Objetivo: comprender cómo se produce el cuidado transitorio del enfermero al anciano con marcapasos artificial. Método: investigación cualitativa, realizada en un hospital filantrópico de la ciudad de Salvador, Bahía, Brasil. Participaron 14 enfermeros que laboran en las unidades de internación quirúrgica y cardíaca. Los datos fueron recolectados entre agosto y noviembre de 2020, a través de entrevistas semiestructuradas, y analizados utilizando el marco metodológico Discurso del Sujeto Colectivo y discutidos a la luz de la teoría de las transiciones de Afaf Meleis. Resultados: se identificó el conocimiento incipiente de las enfermeras sobre los cuidados transicionales. Se observó que el informe de alta de enfermería es un instrumento facilitador para la transición asistencial. Consideraciones finales: el estudio señaló que el cuidado transicional de enfermeras al anciano con marcapasos artificiales no tiene un fundamento teórico, reportando como prioridad el cuidado con la tarjeta de identificación del marcapasos y con la herida quirúrgica.


RESUMO Objetivo: apreender como ocorre o cuidado transicional da enfermeira ao idoso com marcapasso artificial. Método: pesquisa qualitativa, realizada em um hospital filantrópico, na cidade de Salvador, Bahia, Brasil. Participaram 14 enfermeiras atuantes nas unidades de internação cirúrgica e cardiológica. Os dados foram coletados entre agosto e novembro de 2020, por meio de entrevista semiestruturada, e analisados pelo referencial metodológico Discurso do Sujeito Coletivo e discutidos à luz da teoria das transições de Afaf Meleis. Resultados: foi identificado conhecimento insipiente das enfermeiras acerca do cuidado transicional. Observou-se que o relatório de alta de enfermagem constitui um instrumento facilitador para a transição do cuidado. Considerações finais: o estudo apontou que o cuidado transicional de enfermeiras ao idoso com marcapasso artificial não possui fundamentação teórica, relatando como prioridade o cuidado com a carteira de identificação do marcapasso e com a ferida operatória.

20.
Medisur ; 19(6)dic. 2021.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1405850

ABSTRACT

RESUMEN En Cuba, el primer implante de marcapasos se realizó el 6 de julio de 1964, mientras que en Cienfuegos se inicia esta actividad en 1979, por un grupo de profesionales liderados por el Dr. Francisco Riverón Mena, quien se mantuvo durante más de diez años al frente de la estimulación cardíaca, en el Hospital Dr. Gustavo Aldereguía Lima. El presente trabajo se propone describir el método para el implante de marcapasos permanente aplicado en dicha institución, introducido por el Dr. Riverón, como alternativa al modo convencional. Esta técnica requiere muy poca utilización de radiaciones ionizantes; resulta eficaz y más segura, tanto para el paciente como para el personal de salud, pues se emplea radioscopia solo en el último momento del procedimiento, lo cual la diferencia del método convencional. Aunque en la actualidad no se practica, durante la etapa que se aplicó en el hospital, brindó seguridad a pacientes y personal de salud, por lo que debería retomarse su uso.


ABSTRACT In Cuba, the first pacemaker implant was carried out on July 6, 1964, while in Cienfuegos this activity began in 1979, by a group of professionals led by Dr. Francisco Riverón Mena, who stayed for more than ten years in charge of cardiac stimulation, at the Dr. Gustavo Aldereguía Lima Hospital. The present work aims to describe the method for permanent pacemaker implantation applied in said institution, introduced by Dr. Riverón, as an alternative to the conventional mode. This technique requires very little use of ionizing radiation; It is effective and safer, both for the patient and for the health personnel, since fluoroscopy is used only at the last moment of the procedure, which differentiates it from the conventional method. Although it is not currently practiced, during the stage that it was applied in the hospital, it provided security to patients and health personnel, so its use should be resumed.

SELECTION OF CITATIONS
SEARCH DETAIL