Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 967
Filter
1.
JMIR Form Res ; 8: e53977, 2024 Aug 07.
Article in English | MEDLINE | ID: mdl-39110968

ABSTRACT

BACKGROUND: Wearable physiological monitoring devices are promising tools for remote monitoring and early detection of potential health changes of interest. The widespread adoption of such an approach across communities and over long periods of time will require an automated data platform for collecting, processing, and analyzing relevant health information. OBJECTIVE: In this study, we explore prospective monitoring of individual health through an automated data collection, metrics extraction, and health anomaly analysis pipeline in free-living conditions over a continuous monitoring period of several months with a focus on viral respiratory infections, such as influenza or COVID-19. METHODS: A total of 59 participants provided smartwatch data and health symptom and illness reports daily over an 8-month window. Physiological and activity data from photoplethysmography sensors, including high-resolution interbeat interval (IBI) and step counts, were uploaded directly from Garmin Fenix 6 smartwatches and processed automatically in the cloud using a stand-alone, open-source analytical engine. Health risk scores were computed based on a deviation in heart rate and heart rate variability metrics from each individual's activity-matched baseline values, and scores exceeding a predefined threshold were checked for corresponding symptoms or illness reports. Conversely, reports of viral respiratory illnesses in health survey responses were also checked for corresponding changes in health risk scores to qualitatively assess the risk score as an indicator of acute respiratory health anomalies. RESULTS: The median average percentage of sensor data provided per day indicating smartwatch wear compliance was 70%, and survey responses indicating health reporting compliance was 46%. A total of 29 elevated health risk scores were detected, of which 12 (41%) had concurrent survey data and indicated a health symptom or illness. A total of 21 influenza or COVID-19 illnesses were reported by study participants; 9 (43%) of these reports had concurrent smartwatch data, of which 6 (67%) had an increase in health risk score. CONCLUSIONS: We demonstrate a protocol for data collection, extraction of heart rate and heart rate variability metrics, and prospective analysis that is compatible with near real-time health assessment using wearable sensors for continuous monitoring. The modular platform for data collection and analysis allows for a choice of different wearable sensors and algorithms. Here, we demonstrate its implementation in the collection of high-fidelity IBI data from Garmin Fenix 6 smartwatches worn by individuals in free-living conditions, and the prospective, near real-time analysis of the data, culminating in the calculation of health risk scores. To our knowledge, this study demonstrates for the first time the feasibility of measuring high-resolution heart IBI and step count using smartwatches in near real time for respiratory illness detection over a long-term monitoring period in free-living conditions.

2.
Sensors (Basel) ; 24(15)2024 Aug 04.
Article in English | MEDLINE | ID: mdl-39124087

ABSTRACT

Transcatheter aortic valve implantation (TAVI) was initially developed for adult patients, but there is a growing interest to expand this procedure to younger individuals with longer life expectancies. However, the gradual degradation of biological valve leaflets in transcatheter heart valves (THV) presents significant challenges for this extension. This study aimed to establish a multiphysics computational framework to analyze structural and flow measurements of TAVI and evaluate the integration of optical fiber and photoplethysmography (PPG) sensors for monitoring valve function. A two-way fluid-solid interaction (FSI) analysis was performed on an idealized aortic vessel before and after the virtual deployment of the SAPIEN 3 Ultra (S3) THV. Subsequently, an analytical analysis was conducted to estimate the PPG signal using computational flow predictions and to analyze the effect of different pressure gradients and distances between PPG sensors. Circumferential strain estimates from the embedded optical fiber in the FSI model were highest in the sinus of Valsalva; however, the optimal fiber positioning was found to be distal to the sino-tubular junction to minimize bending effects. The findings also demonstrated that positioning PPG sensors both upstream and downstream of the bioprosthesis can be used to effectively assess the pressure gradient across the valve. We concluded that computational modeling allows sensor design to quantify vessel wall strain and pressure gradients across valve leaflets, with the ultimate goal of developing low-cost monitoring systems for detecting valve deterioration.


Subject(s)
Heart Valve Prosthesis , Humans , Photoplethysmography/methods , Aortic Valve/physiology , Aortic Valve/surgery , Monitoring, Physiologic/methods , Monitoring, Physiologic/instrumentation , Transcatheter Aortic Valve Replacement , Hemodynamics/physiology , Optical Fibers
3.
J Clin Sleep Med ; 2024 Aug 12.
Article in English | MEDLINE | ID: mdl-39132687

ABSTRACT

STUDY OBJECTIVES: Since 2019, the FDA has cleared nine novel obstructive sleep apnea (OSA)-detecting wearables for home sleep apnea testing, with many now commercially available for sleep clinicians to integrate into their clinical practices. To help clinicians comprehend these devices and their functionalities, we meticulously reviewed their operating mechanisms, sensors, algorithms, data output, and related performance evaluation literature. METHODS: We collected information from PubMed, FDA clearance documents, ClinicalTrial.gov, and web sources, with direct industry input whenever feasible. RESULTS: In this "device-centered" review, we broadly categorized these wearables into two main groups: those that primarily harness Photoplethysmography (PPG) data and those that do not. The former include the peripheral arterial tonometry (PAT)-based devices. The latter was further broken down into two key subgroups: acoustic-based and respiratory effort-based devices. We provided a performance evaluation literature review and objectively compared device-derived metrics and specifications pertinent to sleep clinicians. Detailed demographics of study populations, exclusion criteria, and pivotal statistical analyses of the key validation studies are summarized. CONCLUSIONS: In the foreseeable future, these novel OSA-detecting wearables may emerge as primary diagnostic tools for patients at risk for moderate-to-severe OSA without significant comorbidities. While more devices are anticipated to join this category, there remains a critical need for cross-device comparison studies as well as independent performance evaluation and outcome research in diverse populations. Now is the moment for sleep clinicians to immerse themselves in understanding these emerging tools to ensure our patient-centered care is improved through the appropriate implementation and utilization of these novel sleep technologies.

4.
Physiol Meas ; 2024 Aug 06.
Article in English | MEDLINE | ID: mdl-39106894

ABSTRACT

The widespread adoption of Photoplethysmography (PPG) as a non-invasive method for detecting blood volume variations and deriving vital physiological parameters reflecting health status has surged, primarily due to its accessibility, cost-effectiveness, and non-intrusive nature. This has led to extensive research around this technique in both daily life and clinical applications. Interestingly, despite the existence of contradictory explanations of the underlying mechanism of PPG signals across various applications, a systematic investigation into this crucial matter has not been conducted thus far. This gap in understanding hinders the full exploitation of PPG technology and undermines its accuracy and reliability in numerous applications. Building upon a comprehensive review of the fundamental principles and technological advancements in PPG, this paper initially attributes the origin of PPG signals to a combination of physical and physiological transmission processes. Furthermore, three distinct models outlining the concerned physiological transmission processes are synthesized, with each model undergoing critical examination based on theoretical underpinnings, empirical evidence, and constraints. The ultimate objective is to form a fundamental framework for a better understanding of physiological transmission processes in PPG signal generation and to facilitate the development of more reliable technologies for detecting physiological signals. .

5.
JMIR Cardio ; 8: e57241, 2024 Aug 05.
Article in English | MEDLINE | ID: mdl-39102277

ABSTRACT

BACKGROUND: The key to reducing the immense morbidity and mortality burdens of cardiovascular diseases is to help people keep their blood pressure (BP) at safe levels. This requires that more people with hypertension be identified, diagnosed, and given tools to lower their BP. BP monitors are critical to hypertension diagnosis and management. However, there are characteristics of conventional BP monitors (oscillometric cuff sphygmomanometers) that hinder rapid and effective hypertension diagnosis and management. Calibration-free, software-only BP monitors that operate on ubiquitous mobile devices can enable on-demand BP monitoring, overcoming the hardware barriers of conventional BP monitors. OBJECTIVE: This study aims to investigate the accuracy of a contactless BP monitor software app for classifying the full range of clinically relevant BPs as hypertensive or nonhypertensive and to evaluate its accuracy for measuring the pulse rate (PR) and BP of people with BPs relevant to stage-1 hypertension. METHODS: The software app, known commercially as Lifelight, was investigated following the data collection and data analysis methodology outlined in International Organization for Standardization (ISO) 81060-2:2018/AMD 1:2020 "Non-invasive Sphygmomanometers-Part 2: Clinical investigation of automated measurement type." This validation study was conducted by the independent laboratory Element Materials Technology Boulder (formerly Clinimark). The study generated data from 85 people aged 18-85 years with a wide-ranging distribution of BPs specified in ISO 81060-2:2018/AMD 1:2020. At least 20% were required to have Fitzpatrick scale skin tones of 5 or 6 (ie, dark skin tones). The accuracy of the app's BP measurements was assessed by comparing its BP measurements with measurements made by dual-observer manual auscultation using the same-arm sequential method specified in ISO 81060-2:2018/AMD 1:2020. The accuracy of the app's PR measurements was assessed by comparing its measurements with concurrent electroencephalography-derived heart rate values. RESULTS: The app measured PR with an accuracy root-mean-square of 1.3 beats per minute and mean absolute error of 1.1 (SD 0.8) beats per minute. The sensitivity and specificity with which it determined that BPs exceeded the in-clinic systolic threshold for hypertension diagnosis were 70.1% and 71.7%, respectively. These rates are consistent with those reported for conventional BP monitors in a literature review by The National Institute for Health and Care Excellence. The app's mean error for measuring BP in the range of normotension and stage-1 hypertension (ie, 65/85, 76% of participants) was 6.5 (SD 12.9) mm Hg for systolic BP and 0.4 (SD 10.6) mm Hg for diastolic BP. Mean absolute error was 11.3 (SD 10.0) mm Hg and 8.6 (SD 6.8) mm Hg, respectively. CONCLUSIONS: A calibration-free, software-only medical device was independently tested against ISO 81060-2:2018/AMD 1:2020. The safety and performance demonstrated in this study suggest that this technique could be a potential solution for rapid and scalable screening and management of hypertension.

6.
Front Cardiovasc Med ; 11: 1432876, 2024.
Article in English | MEDLINE | ID: mdl-39077110

ABSTRACT

Atrial fibrillation (AF) significantly increases the risk of stroke and heart failure, but is frequently asymptomatic and intermittent; therefore, its timely diagnosis poses challenges. Early detection in selected patients may aid in stroke prevention and mitigate structural heart complications through prompt intervention. Smartwatches, coupled with powerful artificial intelligence (AI)-enabled algorithms, offer a promising tool for early detection due to their widespread use, easiness of use, and potential cost-effectiveness. Commercially available smartwatches have gained clearance from the FDA to detect AF and are becoming increasingly popular. Despite their promise, the evolving landscape of AI-enabled smartwatch-based AF detection raises questions about the clinical value of this technology. Following the ongoing digital transformation of healthcare, clinicians should familiarize themselves with how AI-enabled smartwatches function in AF detection and navigate their role in clinical settings to deliver optimal patient care. In this review, we provide a concise overview of the characteristics of AI-enabled smartwatch algorithms, their diagnostic performance, clinical value, limitations, and discuss future perspectives in AF diagnosis.

7.
Sci Rep ; 14(1): 17075, 2024 Jul 24.
Article in English | MEDLINE | ID: mdl-39048601

ABSTRACT

Among the causes of the annually traffic accidents, driving fatigue is the main culprit. In consequence, it is of great practical significance to carry out the research of driving fatigue detection and early warning system. However, there are still two problems in the latest methods of driving fatigue detection: one is that a single information cannot precisely reflect the actual state of the driver in different fatigue phases, another one is the detection effect is not very well or even difficult to detect under abnormal illumination. In this paper, the multi-task cascaded convolutional networks (MTCNN) and infrared-based remote photo-plethysmography (rPPG) theory are used to extract the driver's facial and physiological information, and the multi-modal specific fatigue information is deeply excavated, and the multi-modal feature fusion model is constructed to comprehensively analyze the driver's fatigue variation tendency. Aiming at the matter of low detection accuracy under abnormal illumination, the multi-modal features extracted from visible light images and infrared images are fused by multi-loss reconstruction (MLR) module, and the driving fatigue detection module is established which is based on Bi-LSTM model by utilizing fatigue timing. The experiments were validated under all-weather illumination scenarios and were carried out on the datasets NTHU-DDD, UTA-RLDDD and FAHD. The results show that the multi-modal driving fatigue detection model has better performance than the single-modal model, and the accuracy is improved by 8.1%. In the abnormal illumination such as strong and weak light, the accuracy of the method can reach 91.7% at the highest and 83.6% at the lowest. Meanwhile, in the normal illumination, it can reach 93.2%.

8.
Sensors (Basel) ; 24(13)2024 Jun 27.
Article in English | MEDLINE | ID: mdl-39000954

ABSTRACT

Stress is the inherent sensation of being unable to handle demands and occurrences. If not properly managed, stress can develop into a chronic condition, leading to the onset of additional chronic health issues, such as cardiovascular illnesses and diabetes. Various stress meters have been suggested in the past, along with diverse approaches for its estimation. However, in the case of more serious health issues, such as hypertension and diabetes, the results can be significantly improved. This study presents the design and implementation of a distributed wearable-sensor computing platform with multiple channels. The platform aims to estimate the stress levels in diabetes patients by utilizing a fuzzy logic algorithm that is based on the assessment of several physiological indicators. Additionally, a mobile application was created to monitor the users' stress levels and integrate data on their blood pressure and blood glucose levels. To obtain better performance metrics, validation experiments were carried out using a medical database containing data from 128 patients with chronic diabetes, and the initial results are presented in this study.


Subject(s)
Algorithms , Diabetes Mellitus, Type 2 , Fuzzy Logic , Humans , Diabetes Mellitus, Type 2/physiopathology , Stress, Psychological/physiopathology , Blood Pressure/physiology , Wearable Electronic Devices , Male , Blood Glucose/analysis , Female , Artificial Intelligence , Middle Aged , Mobile Applications , Monitoring, Physiologic/methods
9.
Sensors (Basel) ; 24(13)2024 Jun 28.
Article in English | MEDLINE | ID: mdl-39000977

ABSTRACT

(1) Background: The objective of this study was to predict the vascular health status of elderly women during exercise using pulse wave data and Temporal Convolutional Neural Networks (TCN); (2) Methods: A total of 492 healthy elderly women aged 60-75 years were recruited for the study. The study utilized a cross-sectional design. Vascular endothelial function was assessed non-invasively using Flow-Mediated Dilation (FMD). Pulse wave characteristics were quantified using photoplethysmography (PPG) sensors, and motion-induced noise in the PPG signals was mitigated through the application of a recursive least squares (RLS) adaptive filtering algorithm. A fixed-load cycling exercise protocol was employed. A TCN was constructed to classify flow-mediated dilation (FMD) into "optimal", "impaired", and "at risk" levels; (3) Results: TCN achieved an average accuracy of 79.3%, 84.8%, and 83.2% in predicting FMD at the "optimal", "impaired", and "at risk" levels, respectively. The results of the analysis of variance (ANOVA) comparison demonstrated that the accuracy of the TCN in predicting FMD at the impaired and at-risk levels was significantly higher than that of Long Short-Term Memory (LSTM) networks and Random Forest algorithms; (4) Conclusions: The use of pulse wave data during exercise combined with the TCN for predicting the vascular health status of elderly women demonstrated high accuracy, particularly in predicting impaired and at-risk FMD levels. This indicates that the integration of exercise pulse wave data with TCN can serve as an effective tool for the assessment and monitoring of the vascular health of elderly women.


Subject(s)
Exercise , Neural Networks, Computer , Photoplethysmography , Pulse Wave Analysis , Humans , Female , Photoplethysmography/methods , Aged , Pulse Wave Analysis/methods , Exercise/physiology , Middle Aged , Cross-Sectional Studies , Algorithms
10.
Eur Heart J Digit Health ; 5(4): 461-468, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39081939

ABSTRACT

Aims: Direct current cardioversion (DCCV) is a commonly utilized rhythm control technique for atrial fibrillation. Follow-up typically comprises a hospital visit for 12-lead electrocardiogram (ECG) two weeks post-DCCV. We report the feasibility, costs, and environmental benefit of remote photoplethysmography (PPG) monitoring as an alternative. Methods and results: We retrospectively analysed DCCV cases at our centre from May 2020 to October 2022. Patients were stratified into those with remote PPG follow-up and those with traditional 12-lead ECG follow-up. Monitoring type was decided by the specialist nurse performing the DCCV at the time of the procedure after discussing with the patient and offering them both options if appropriate. Outcomes included the proportion of patients who underwent PPG monitoring, patient compliance and experience, and cost, travel, and environmental impact. Four hundred sixteen patients underwent 461 acutely successful DCCV procedures. Two hundred forty-six underwent PPG follow-up whilst 214 underwent ECG follow-up. Patient compliance was high (PPG 89.4% vs. ECG 89.8%; P > 0.999) and the majority of PPG users (90%) found the app easy to use. Sinus rhythm was maintained in 71.1% (PPG) and 64.7% (ECG) of patients (P = 0.161). Twenty-nine (11.8%) PPG patients subsequently required an ECG either due to non-compliance, technical failure, or inconclusive PPG readings. Despite this, mean healthcare costs (£47.91 vs. £135 per patient; P < 0.001) and median cost to the patient (£0 vs. £5.97; P < 0.001) were lower with PPG. Median travel time per patient (0 vs. 44 min; P < 0.001) and CO2 emissions (0 vs. 3.59 kg; P < 0.001) were also lower with PPG. No safety issues were identified. Conclusion: Remote PPG monitoring is a viable method of assessing for arrhythmia recurrence post-DCCV. This approach may save patients significant travel time, reduce environmental CO2 emission, and be cost saving in a publicly-funded healthcare system.

11.
Sci Rep ; 14(1): 16149, 2024 07 12.
Article in English | MEDLINE | ID: mdl-38997404

ABSTRACT

The educational environment plays a vital role in the development of students who participate in athletic pursuits both in terms of their physical health and their ability to detect fatigue. As a result of recent advancements in deep learning and biosensors benefitting from edge computing resources, we are now able to monitor the physiological fatigue of students participating in sports in real time. These devices can then be used to analyze the data using contemporary technology. In this paper, we present an innovative deep learning framework for forecasting fatigue in athletic students following physical exercise. It addresses the issue of lack of precision computational models and extensive data analysis in current approaches to monitoring students' physical activity. In our study, we classified fatigue and non-fatigue based on photoplethysmography (PPG) signals. Several deep learning models are compared in the study. Using limited training data, determining the optimal parameters for PPG presents a significant challenge. For datasets containing many data points, several models were trained using PPG signals: a deep residual network convolutional neural network (ResNetCNN) ResNetCNN, an Xception architecture, a bidirectional long short-term memory (BILSTM), and a combination of these models. Training and testing datasets were assigned using a fivefold cross validation approach. Based on the testing dataset, the model demonstrated a proper classification accuracy of 91.8%.


Subject(s)
Deep Learning , Exercise , Fatigue , Photoplethysmography , Humans , Fatigue/diagnosis , Fatigue/physiopathology , Photoplethysmography/methods , Exercise/physiology , Neural Networks, Computer , Male , Female , Signal Processing, Computer-Assisted , Young Adult
12.
Sci Rep ; 14(1): 16450, 2024 07 16.
Article in English | MEDLINE | ID: mdl-39014018

ABSTRACT

Continuous blood pressure (BP) monitoring is essential for managing cardiovascular disease. However, existing devices often require expert handling, highlighting the need for alternative methods to simplify the process. Researchers have developed various methods using physiological signals to address this issue. Yet, many of these methods either fall short in accuracy according to the BHS, AAMI, and IEEE standards for BP measurement devices or suffer from low computational efficiency due to the complexity of their models. To solve this problem, we developed a BP prediction system that merges extracted features of PPG and ECG from two pulses of both signals using convolutional and LSTM layers, followed by incorporating the R-to-R interval durations as additional features for predicting systolic (SBP) and diastolic (DBP) blood pressure. Our findings indicate that the prediction accuracies for SBP and DBP were 5.306 ± 7.248 mmHg with a 0.877 correlation coefficient and 3.296 ± 4.764 mmHg with a 0.918 correlation coefficient, respectively. We found that our proposed model achieved a robust performance on the MIMIC III dataset with a minimum architectural design and high-level accuracy compared to existing methods. Thus, our method not only meets the passing category for BHS, AAMI, and IEEE guidelines but also stands out as the most rapidly accurate deep-learning-based BP measurement device currently available.


Subject(s)
Blood Pressure , Electrocardiography , Photoplethysmography , Humans , Electrocardiography/methods , Photoplethysmography/methods , Photoplethysmography/instrumentation , Blood Pressure Determination/methods , Blood Pressure Determination/instrumentation , Signal Processing, Computer-Assisted , Neural Networks, Computer , Male , Female , Deep Learning , Algorithms
14.
Comput Biol Med ; 179: 108873, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39053334

ABSTRACT

Video-based remote photoplethysmography (rPPG) has emerged as a promising technology for non-contact vital sign monitoring, especially under controlled conditions. However, the accurate measurement of vital signs in real-world scenarios faces several challenges, including artifacts induced by videocodecs, low-light noise, degradation, low dynamic range, occlusions, and hardware and network constraints. In this article, a systematic and comprehensive investigation of these issues is conducted, measuring their detrimental effects on the quality of rPPG measurements. Additionally, practical strategies are proposed for mitigating these challenges to improve the dependability and resilience of video-based rPPG systems. Methods for effective biosignal recovery in the presence of network limitations are detailed, along with denoising and inpainting techniques aimed at preserving video frame integrity. Compared to previous studies, this paper addresses a broader range of variables and demonstrates improved accuracy across various rPPG methods, emphasizing generalizability for practical applications in diverse scenarios with varying data quality. Extensive evaluations and direct comparisons demonstrate the effectiveness of these approaches in enhancing rPPG measurements under challenging environments, contributing to the development of more reliable and effective remote vital sign monitoring technologies.


Subject(s)
Artifacts , Photoplethysmography , Video Recording , Humans , Photoplethysmography/methods , Signal Processing, Computer-Assisted , Male , Female , Adult , Monitoring, Physiologic/methods
15.
Front Digit Health ; 6: 1337667, 2024.
Article in English | MEDLINE | ID: mdl-38946728

ABSTRACT

Introduction: Heart rate variability biofeedback (HRVB) is a well-studied intervention known for its positive effects on emotional, cognitive, and physiological well-being, including relief from depressive symptoms. However, its practical use is hampered by high costs and a lack of trained professionals. Smartphone-based HRVB, which eliminates the need for external devices, offers a promising alternative, albeit with limited research. Additionally, premenstrual symptoms are highly prevalent among menstruating individuals, and there is a need for low-cost, accessible interventions with minimal side effects. With this pilot study, we aim to test, for the first time, the influence of smartphone-based HRVB on depressive and premenstrual symptoms, as well as anxiety/stress symptoms and attentional control. Methods: Twenty-seven participants with above-average premenstrual or depressive symptoms underwent a 4-week photoplethysmography smartphone-based HRVB intervention using a waitlist-control design. Laboratory sessions were conducted before and after the intervention, spaced exactly 4 weeks apart. Assessments included resting vagally mediated heart rate variability (vmHRV), attentional control via the revised attention network test (ANT-R), depressive symptoms assessed with the BDI-II questionnaire, and stress/anxiety symptoms measured using the DASS questionnaire. Premenstrual symptomatology was recorded through the PAF questionnaire if applicable. Data analysis employed linear mixed models. Results: We observed improvements in premenstrual, depressive, and anxiety/stress symptoms, as well as the Executive Functioning Score of the ANT-R during the intervention period but not during the waitlist phase. However, we did not find significant changes in vmHRV or the Orienting Score of the ANT-R. Discussion: These findings are promising, both in terms of the effectiveness of smartphone-based HRVB and its potential to alleviate premenstrual symptoms. Nevertheless, to provide a solid recommendation regarding the use of HRVB for improving premenstrual symptoms, further research with a larger sample size is needed to replicate these effects.

16.
Comput Methods Programs Biomed ; 254: 108283, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38901273

ABSTRACT

BACKGROUND AND OBJECTIVE: Detection of the dicrotic notch (DN) within a cardiac cycle is essential for assessment of cardiac output, calculation of pulse wave velocity, estimation of left ventricular ejection time, and supporting feature-based machine learning models for noninvasive blood pressure estimation, and hypotension, or hypertension prediction. In this study, we present a new algorithm based on the iterative envelope mean (IEM) method to detect automatically the DN in arterial blood pressure (ABP) and photoplethysmography (PPG) waveforms. METHODS: The algorithm was evaluated on both ABP and PPG waveforms from a large perioperative dataset (MLORD dataset) comprising 17,327 patients. The analysis involved a total of 1,171,288 cardiac cycles for ABP waveforms and 3,424,975 cardiac cycles for PPG waveforms. To evaluate the algorithm's performance, the systolic phase duration (SPD) was employed, which represents the duration from the onset of the systolic phase to the DN in the cardiac cycle. Correlation plots and regression analysis were used to compare the algorithm against marked DN detection, while box plots and Bland-Altman plots were used to compare its performance with both marked DN detection and an established DN detection technique (second derivative). The marking of the DN temporal location was carried out by an experienced researcher using the help of the 'find_peaks' function from the scipy Python package, serving as a reference for the evaluation. The marking was visually validated by both an engineer and an anesthesiologist. The robustness of the algorithm was evaluated as the DN was made less visually distinct across signal-to-noise ratios (SNRs) ranging from -30 dB to -5 dB in both ABP and PPG waveforms. RESULTS: The correlation between SPD estimated by the algorithm and that marked by the researcher is strong for both ABP (R2(87,343) =0.99, p<.001) and PPG (R2(86,764) =0.98, p<.001) waveforms. The algorithm had a lower mean error of DN detection (s): 0.0047 (0.0029) for ABP waveforms and 0.0046 (0.0029) for PPG waveforms, compared to 0.0693 (0.0770) for ABP and 0.0968 (0.0909) for PPG waveforms for the established 2nd derivative method. The algorithm has high rate of detectability of DN detection for SNR of >= -9 dB for ABP waveforms and >= -12 dB for PPG waveforms indicating robust performance in detecting the DN when it is less visibly distinct. CONCLUSION: Our proposed IEM- based algorithm can detect DN in both ABP and PPG waveforms with low computational cost, even in cases where it is not distinctly defined within a cardiac cycle of the waveform ('DN-less signals'). The algorithm can potentially serve as a valuable, fast, and reliable tool for extracting features from ABP and PPG waveforms. It can be especially beneficial in medical applications where DN-based features, such as SPD, diastolic phase duration, and DN amplitude, play a significant role.


Subject(s)
Algorithms , Photoplethysmography , Photoplethysmography/methods , Humans , Arterial Pressure , Blood Pressure Determination/methods , Pulse Wave Analysis/methods , Signal Processing, Computer-Assisted
17.
JMIR Cancer ; 10: e51210, 2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38900505

ABSTRACT

BACKGROUND: Exercise intensity (eg, target heart rate [HR]) is a fundamental component of exercise prescription to elicit health benefits in cancer survivors. Despite the validity of chest-worn monitors, their feasibility in community and unsupervised exercise settings may be challenging. As wearable technology continues to improve, consumer-based wearable sensors may represent an accessible alternative to traditional monitoring, offering additional advantages. OBJECTIVE: The purpose of this study was to examine the agreement between the Polar H10 chest monitor and Fitbit Inspire HR for HR measurement in breast cancer survivors enrolled in the intervention arm of a randomized, pilot exercise trial. METHODS: Participants included breast cancer survivors (N=14; aged 38-72 years) randomized to a 12-week aerobic exercise program. This program consisted of three 60-minute, moderate-intensity walking sessions per week, either in small groups or one-on-one, facilitated by a certified exercise physiologist and held at local community fitness centers. As originally designed, the exercise prescription included 36 supervised sessions at a fitness center. However, due to the COVID-19 pandemic, the number of supervised sessions varied depending on whether participants enrolled before or after March 2020. During each exercise session, HR (in beats per minute) was concurrently measured via a Polar H10 chest monitor and a wrist-worn Fitbit Inspire HR at 5 stages: pre-exercise rest; midpoint of warm-up; midpoint of exercise session; midpoint of cool-down; and postexercise recovery. The exercise physiologist recorded the participant's HR from each device at the midpoint of each stage. HR agreement between the Polar H10 and Fitbit Inspire HR was assessed using Lin concordance correlation coefficient (rc) with a 95% CI. Lin rc ranges from 0 to 1.00, with 0 indicating no concordance and 1.00 indicating perfect concordance. Relative error rates were calculated to examine differences across exercise session stages. RESULTS: Data were available for 200 supervised sessions across the sample (session per participant: mean 13.33, SD 13.7). By exercise session stage, agreement between the Polar H10 monitor and the Fitbit was highest during pre-exercise seated rest (rc=0.76, 95% CI 0.70-0.81) and postexercise seated recovery (rc=0.89, 95% CI 0.86-0.92), followed by the midpoint of exercise (rc=0.63, 95% CI 0.55-0.70) and cool-down (rc=0.68, 95% CI 0.60-0.74). The agreement was lowest during warm-up (rc=0.39, 95% CI 0.27-0.49). Relative error rates ranged from -3.91% to 3.09% and were greatest during warm-up (relative error rate: mean -3.91, SD 11.92%). CONCLUSIONS: The Fitbit overestimated HR during peak exercise intensity, posing risks for overexercising, which may not be safe for breast cancer survivors' fitness levels. While the Fitbit Inspire HR may be used to estimate exercise HR, precautions are needed when considering participant safety and data interpretation. TRIAL REGISTRATION: Clinicaltrials.gov NCT03980626; https://clinicaltrials.gov/study/NCT03980626?term=NCT03980626&rank=1.

18.
Sensors (Basel) ; 24(12)2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38931550

ABSTRACT

The remote monitoring of vital signs via wearable devices holds significant potential for alleviating the strain on hospital resources and elder-care facilities. Among the various techniques available, photoplethysmography stands out as particularly promising for assessing vital signs such as heart rate, respiratory rate, oxygen saturation, and blood pressure. Despite the efficacy of this method, many commercially available wearables, bearing Conformité Européenne marks and the approval of the Food and Drug Administration, are often integrated within proprietary, closed data ecosystems and are very expensive. In an effort to democratize access to affordable wearable devices, our research endeavored to develop an open-source photoplethysmographic sensor utilizing off-the-shelf hardware and open-source software components. The primary aim of this investigation was to ascertain whether the combination of off-the-shelf hardware components and open-source software yielded vital-sign measurements (specifically heart rate and respiratory rate) comparable to those obtained from more expensive, commercially endorsed medical devices. Conducted as a prospective, single-center study, the research involved the assessment of fifteen participants for three minutes in four distinct positions, supine, seated, standing, and walking in place. The sensor consisted of four PulseSensors measuring photoplethysmographic signals with green light in reflection mode. Subsequent signal processing utilized various open-source Python packages. The heart rate assessment involved the comparison of three distinct methodologies, while the respiratory rate analysis entailed the evaluation of fifteen different algorithmic combinations. For one-minute average heart rates' determination, the Neurokit process pipeline achieved the best results in a seated position with a Spearman's coefficient of 0.9 and a mean difference of 0.59 BPM. For the respiratory rate, the combined utilization of Neurokit and Charlton algorithms yielded the most favorable outcomes with a Spearman's coefficient of 0.82 and a mean difference of 1.90 BrPM. This research found that off-the-shelf components are able to produce comparable results for heart and respiratory rates to those of commercial and approved medical wearables.


Subject(s)
Heart Rate , Photoplethysmography , Respiratory Rate , Signal Processing, Computer-Assisted , Software , Wearable Electronic Devices , Humans , Photoplethysmography/methods , Photoplethysmography/instrumentation , Respiratory Rate/physiology , Heart Rate/physiology , Male , Female , Monitoring, Physiologic/methods , Monitoring, Physiologic/instrumentation , Adult , Prospective Studies , Algorithms
19.
Sensors (Basel) ; 24(12)2024 Jun 16.
Article in English | MEDLINE | ID: mdl-38931686

ABSTRACT

Photoplethysmography (PPG) is widely utilized in wearable healthcare devices due to its convenient measurement capabilities. However, the unrestricted behavior of users often introduces artifacts into the PPG signal. As a result, signal processing and quality assessment play a crucial role in ensuring that the information contained in the signal can be effectively acquired and analyzed. Traditionally, researchers have discussed signal quality and processing algorithms separately, with individual algorithms developed to address specific artifacts. In this paper, we propose a quality-aware signal processing mechanism that evaluates incoming PPG signals using the signal quality index (SQI) and selects the appropriate processing method based on the SQI. Unlike conventional processing approaches, our proposed mechanism recommends processing algorithms based on the quality of each signal, offering an alternative option for designing signal processing flows. Furthermore, our mechanism achieves a favorable trade-off between accuracy and energy consumption, which are the key considerations in long-term heart rate monitoring.


Subject(s)
Algorithms , Heart Rate , Photoplethysmography , Signal Processing, Computer-Assisted , Photoplethysmography/methods , Heart Rate/physiology , Humans , Monitoring, Physiologic/methods , Wearable Electronic Devices
20.
Sensors (Basel) ; 24(12)2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38931747

ABSTRACT

The development of non-contact techniques for monitoring human vital signs has significant potential to improve patient care in diverse settings. By facilitating easier and more convenient monitoring, these techniques can prevent serious health issues and improve patient outcomes, especially for those unable or unwilling to travel to traditional healthcare environments. This systematic review examines recent advancements in non-contact vital sign monitoring techniques, evaluating publicly available datasets and signal preprocessing methods. Additionally, we identified potential future research directions in this rapidly evolving field.


Subject(s)
Vital Signs , Humans , Vital Signs/physiology , Monitoring, Physiologic/methods , Signal Processing, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL