ABSTRACT
The analysis of bite marks is a challenging and convoluted part of Forensic Odontology. Various interrelated factors such as location of the bite and skin elasticity complicate the bite mark analysis. The relationship between the bite mark and the biochemical properties of skin has been well-documented but there is need to consider the variety of skin tones as a factor to explore. The aim of this pilot study was to analyse the appearance of bite marks on 5 different types of skin tones of 15 subjects (6 males and 9 females) from 11 nationalities and age ranged from 21 to 46 years. A pair of 3D printed dental cast was transferred onto a mechanical apparatus for production of experimental bitemarks by using 12.5 kg of weight. Common imaging modalities including conventional, infrared and ultraviolet light were used to record the bite mark images for following visual assessment. The different skin tones were categorized using Fitzpatrick scale (1975) and a colour chart was used to compare the changes on skin after 15 minutes of bite registration. According to the results, the force was well tolerated by the subjects producing a well-defined bite mark, although males showed a less prominent mark than females irrespective of the skin tone and nationality. Neither bruises nor significant changes in the colour of bite mark could be appreciated among the subjects. The different types of skin tones did not affect the registration of bite mark applying a force of 122.5.N for 15 seconds in this sample
A análise das marcas de mordida é a parte mais desafiadora e complicada da Odontologia Forense. Vários fatores inter-relacionados, como a localização da mordida e a elasticidade da pele, complicam a análise da marca de mordida. A relação entre a marca de mordida e as propriedades bioquímicas da pele tem sido bem documentada, mas é preciso considerar a variedade de tons de pele como um fator a ser explorado. O objetivo deste estudo piloto foi analisar o aparecimento de marcas de mordida em 5 tipos diferentes de tons de pele de 15 indivíduos (6 homens e 9 mulheres) de 11 nacionalidades e idades entre 21 a 46 anos. Um par de modelos dentários impressos em 3D foi transferido para um aparelho mecânico para a produção de marcas de mordida experimentais usando 12,5 kg de peso. Modalidades de imagem digital como convencional, infravermelha e ultravioleta foram usadas para registrar as imagens da marca de mordida para posterior avaliação visual. Os diferentes tons de pele foram categorizados usando a escala de Fitzpatrick e uma cartela de cores foi usada para comparar as alterações na pele após 15 minutos de registro da mordida. De acordo com os resultados a força foi bem tolerada pelos sujeitos, produzindo uma marca de mordida bem definida, embora os homens mostraram uma marca menos proeminente do que as mulheres, independentemente do tom da pele e da nacionalidade. Nenhum hematoma ou mudanças significativas nas cores das marcas de mordida foram encontrados entre os indivíduos. Os diferentes tipos de tons de pele não afetaram o registro da marca de mordida aplicando uma força de 122,5 N por 15 segundos nesta amostra.
ABSTRACT
Introducción: Las emisiones otoacústicas (EOA) son sonidos generados por las células ciliadas externas (CCE). Se ha visto que la generación y registro de las EOA evocadas depende de factores técnicos de evaluación como el nivel de intensidad de los tonos primarios, relación frecuencial entre los tonos, etc. Objetivos: Estudiar el efecto de la variación de la intensidad de los tonos primarios en la amplitud de la respuesta de las EOA producto de distorsión (pd) en individuos con audición normal. Material y método: Se evaluaron 35 individuos a los cuales se les midieron EOApd utilizando diferentes intensidades de tonos primarios: Intensidad baja (I1=50dBSPL e I2=50dBSPL), intensidad media (I1=55dBSPL e I2=65dBSPL) e intensidad alta (I1=70dBSPL e I2=70dBSPL). Resultados: Se observó que para tonos primarios a bajas intensidades (I1=50dBSPL e I2=50dBSPL) existe una disminución tanto en amplitud y presencia de las EOApd, mientras que para tonos primarios a intensidades mayores (I1=55dBSPL e I2=65dBSPL - I1=70dBSPL e I2=70dBSPL) se evidenció un aumento en amplitud y presencia de EOApd en los sujetos estudiados. Conclusión: Se evidencian diferencias estadísticamente significativas en la amplitud de las EOApd al variar la intensidad de los tonos primarios. Por lo cual se puede establecer que las intensidades medias-altas son las más adecuadas para la evaluación de EOApd en sujetos con audición normal.
Introduction: Otoacoustic emissions (OAE) are sounds produced by outer hair cells. The generation and recording of evoked OAE depends on technical factors such as level of intensity of primary tones, frequency relationship between the tones, etc. Aim: To study the effect of varying the intensity of primary tones in the amplitude of the response of Distortion Product OAE (DP) in individuals with normal hearing. Material and method: 35 individuals were measured using different intensities OAEdp primary tones: Low Intensity (I1= I2 =50dBSPL 50dBSPL e), Medium Intensity (11= I2 =65dBSPL 55dBSPL e) and High Intensity (I1 =70dBSPL and I2 =70dBSPL). Results: Using Low primary tones (I1 =I2 =50dBSPL 50dBSPL) there is a decrease in amplitude and presence of DPOAE, while for primary tones at higher intensities (I1 and I2 = = 55dBSPL 65dBSPL -11 =70dBSPL and I2 =70dBSPL) an increase in amplitude and presence of OAEdp in subjects with normal hearing was observed . Conclusion: There are statistically significant differences in OAEdp amplitude by varying the intensity of the primary tones. Therefore medium-high intensities are best suited for the evaluation of OAEdp in subjects with normal hearing.