Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 753
Filter
1.
Revista Digital de Postgrado ; 13(2): e397, ago.2024. tab
Article in Spanish | LILACS | ID: biblio-1567355

ABSTRACT

Introducción: Con el aumento de la prevalencia de obesidad, se esperaría un mayor espesor glúteo, lo que sería un factor importante en futuras intervenciones en región glútea con fines de optimizar mejores resultados estéticos. Objetivo: Correlacionar el índice de masa corporal y el grosor de tejido adiposo en glúteos en voluntarias que acudieron al Servicio de Cirugía Plástica y Reconstructiva del Hospital Dr. Miguel Pérez Carreño entre enero a marzo, 2023. Métodos: El estudio fue prospectivo, descriptivo y de corte transversal. Se utilizó un sonógrafo Sono Eye 1 para realizar las medidas del glúteo. Mediante una báscula, se midió peso y talla, para posteriormente calcular el IMC, fueron 29 voluntarias de sexo femenino entre 18 a 60 años, sin antecedentes quirúrgicos estéticos previos. Las correlaciones fueron evaluadas con el coeficiente de correlación de Pearson. Se consideró un valor significativo si p < 0,05. Los datos fueron tabulados con STATA 17. Resultados: La edad promedio fue 39 ± 12 años. La mayoría con preobesidad (55,2 %). No hubo diferencias estadísticas en grosor de tejido adiposo, de musculo y espesor de glúteo de acuerdo a la lateralidad; de acuerdo al coeficiente de correlación de Pearson, el IMC no hubo asociación con las medidas combinadas del glúteo izquierdo y derecho del grosor de tejido graso (r = 0,137), grosor muscular (r = 0,115) y espesor glúteo (r = 0,193). Conclusión: Los cambios de las medidas antropométricas de acuerdo al índice de masa corporal, no presentaron correlación estadística con el espesor glúteo. (AU)


Introduction: With the increasing prevalence of obesity, a greater gluteal thickness would be expected, which would be an important factor in future interventions in the gluteal region aimed at optimizing better aesthetic outcomes. Objective: To correlate the body mass index (BMI) and the thickness of adipose tissue in the buttocks of volunteers who attended the Plastic and Reconstructive Surgery Service at Dr. Miguel Pérez Carreño Hospital from January to March, 2023. Methods: The study was prospective, descriptive, and cross-sectional. A Sono Eye 1 sonograph was used to measure the gluteal thickness. Using a scale, weight and height were measured to subsequently calculate the BMI; there were 29 female volunteers aged between 18 and 60 years, without previous aesthetic surgical history. Correlations were assessed using Pearson's correlation coefficient. A significant value was considered if p < 0.05. Data were tabulated using STATA 17. Results: The average age was 39 ± 12 years. The majority had pre-obesity (55,2%). There were no statistical differences in adipose tissue thickness, muscle thickness, and gluteal thickness according to laterality; according to Pearson's correlation coefficient, BMI was not associated with combined measurements of left and right buttock adipose tissue thickness (r = 0,137), muscle thickness (r = 0,115), and gluteal thickness (r = 0,193). Conclusion: Changes in anthropometric measurements according to body mass index did not show a statistical correlation with gluteal thickness. (AU)


Subject(s)
Humans , Female , Adult , Middle Aged , Buttocks/surgery , Body Mass Index , Adipose Tissue/surgery , Cross-Sectional Studies , Prospective Studies , Patient Satisfaction , Plastic Surgery Procedures
2.
Nefrologia (Engl Ed) ; 44(3): 344-353, 2024.
Article in English | MEDLINE | ID: mdl-39002995

ABSTRACT

INTRODUCTION AND OBJECTIVES: Functional and durable vascular access is needed for adequate hemodialysis. Arteriovenous fistula is preferred over prosthetic grafts or central venous catheters, but it is associated with high rates of primary failure and maturation failure. Preoperative mapping of arm vessels with color Doppler ultrasound (CDU) has been shown to be helpful in achieving better short and long-term outcomes. Unfortunately, is more time-consuming than a physical examination and requires an experienced examiner and special equipment; some authors defend that CDU should not be part of the routine preoperative assessment. We reported our experience in preoperative vessel mapping using color Doppler ultrasound to purpose a vascular access to the surgical team, surveillance of vascular access, and evaluation of main outcomes (primary failure, maturation failure, and patency). METHODS: This is a single-center retrospective study that includes patients who attended a specific appointment for vascular access planning consultation between January 2019 and December 2021. A nephrologist performed the physical exam and vascular mapping and proposed to the vascular surgeon team a specific type and location of vascular access. Patients were followed until one month after the first hemodialysis through functioning vascular access. RESULTS: In this study, 167 patients were evaluated (114 incident patients - chronic kidney disease stage 4 or 5 - and 53 prevalent patients - under hemodialysis through central venous catheter). The vascular accesses proposed by nephrologist were radial-cephalic arteriovenous fistula in 70 patients (41.9%), brachio-cephalic arteriovenous fistula in 50 patients (29.9%), brachio-basilic arteriovenous fistula in 34 patients (20.4%), arteriovenous graft in 8 patients (4.8%) and central venous catheter in 2 patients (1.2%). Vascular access was constructed in 141 patients: distal arteriovenous fistula in 57 patients (40.4%), brachio-cephalic arteriovenous fistula in 54 patients (38.3%), brachio-basilic AVF in 27 patients (19.1%), and arteriovenous graft in 3 patients (2.1%). The created access corresponds to the proposed access in 129 patients (91.5%). Twenty-two (15.6%) primary failures were registered. Distal arteriovenous fistulas and diabetes mellitus were associated with a higher risk of primary failure (OR=3.929 (1.485-10.392), p=0.004; OR=3.867 (1.235-12.113), p=0.014, respectively). The incidence of maturation failure at eight weeks was 4.8%. The primary patency at 6, 12 and 24 months was 76.3%, 70.4% and 49.2%. Primary assisted patency was 84.8% at 6 and 12 months and 81.3% at 24 months. CONCLUSIONS: This study demonstrates that the study of the entire vascular territory performed with color Doppler ultrasound, within a multidisciplinary team of nephrologists and vascular surgeons, is associated with high rates of autologous access and very low rates of primary failure and maturation failure (almost unprecedented in the literature).


Subject(s)
Arteriovenous Shunt, Surgical , Patient Care Team , Renal Dialysis , Humans , Renal Dialysis/methods , Arteriovenous Shunt, Surgical/methods , Female , Male , Retrospective Studies , Middle Aged , Aged , Ultrasonography, Doppler, Color , Preoperative Care/methods , Vascular Patency
3.
Med Clin (Barc) ; 163(4): 183-185, 2024 08 30.
Article in English, Spanish | MEDLINE | ID: mdl-38880730

ABSTRACT

INTRODUCTION: Transbronchial needle aspiration guided by endobronchial ultrasonography (EBUSTBNA) has the disadvantage of sometimes offering samples of an unsuitable size for an accurate histo-molecular diagnosis. Transbronchial mediastinal cryobiopsy (CRYOEBUS) is a very novel and additional technique to EBUS-TBNA that allows us to obtain larger and quality samples, improving diagnostic performance. MATERIAL AND METHODS: Descriptive study of 110 patients with lesions and/or mediastinal lymphadenopathy who underwent EBUS-TBNA and CRYO-EBUS in a single procedure. Our objective was to analyze the diagnostic profitability and safety of the technique. RESULTS: CRYO-EBUS obtained samples of 0.42cm on average compared to 0.14cm obtained by EBUS-TBNA. The overall diagnostic performance of the techniques was 60% for EBUS-TBNA and 94.5% for CRYO-EBUS. Furthermore, the latter was more sensitive for the diagnosis of both malignant and benign diseases. With a very high security profile. CONCLUSIONS: The CRYO-EBUS technique is cost-effective and safe, and is superior to EBUS-TBNA. Future studies may confirm our findings.


Subject(s)
Bronchoscopy , Cost-Benefit Analysis , Endoscopic Ultrasound-Guided Fine Needle Aspiration , Mediastinum , Humans , Male , Female , Middle Aged , Aged , Bronchoscopy/methods , Bronchoscopy/economics , Bronchoscopy/adverse effects , Endoscopic Ultrasound-Guided Fine Needle Aspiration/adverse effects , Endoscopic Ultrasound-Guided Fine Needle Aspiration/economics , Endoscopic Ultrasound-Guided Fine Needle Aspiration/methods , Adult , Mediastinum/pathology , Aged, 80 and over , Endosonography/methods , Endosonography/economics , Endosonography/adverse effects , Lung Neoplasms/pathology , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/diagnosis , Cryosurgery/methods , Sensitivity and Specificity
4.
Radiologia (Engl Ed) ; 66(3): 219-227, 2024.
Article in English | MEDLINE | ID: mdl-38908883

ABSTRACT

INTRODUCTION: Transfontanellar brain ultrasound is an essential tool for monitoring the size of the ventricles in preterm neonates and has many advantages over other alternative diagnostic techniques, including its accessibility and non-use of ionizing radiation. When considering the normal ventricular size, it is essential to have reference measurements based on age-matched populations. The objective of this article is to present our reference measures, based on a sample of preterm infants that we have studied. METHODS: A retrospective observational study was conducted. Measurements of the Levene index, frontal horn thickness, and Evans index were obtained in preterm neonates from 25 to 45 weeks, over a period of 5 years, between January 2016 and December 2020. After applying the exclusion criteria, a sample of 199 patients and 350 ultrasound scans were obtained. The independent samples t-test and the Mann-Whitney test were used for the comparison of samples. RESULTS: The distribution of the right and left Levene indices was normal (Shapiro-Wilk test with p = 0.16 and 0.05, respectively), unlike the thickness distribution of the frontal horns (p < 0.05 on both sides). No significant differences were detected between the sexes (p = 0.08). A linear correlation was found between the biparietal diameter and the Levene index. CONCLUSION: From the results obtained in our study, we present reference tables for ventricular size, with the 3rd, 25th, 50th, 75th, and 97th, being the first ones made in our country.


Subject(s)
Cerebral Ventricles , Infant, Premature , Nomograms , Humans , Retrospective Studies , Female , Male , Infant, Newborn , Cerebral Ventricles/diagnostic imaging , Cerebral Ventricles/anatomy & histology , Reference Values , Organ Size , Ultrasonography/methods
5.
Rev Esp Geriatr Gerontol ; 59(4): 101497, 2024.
Article in English | MEDLINE | ID: mdl-38795680

ABSTRACT

OBJECTIVES: Evaluate associations between triceps braqui muscle ultrasound measures (TB US) and handgrip strength (HGS), and the sensibility of TB US for low HGS in non-dialysis-dependent chronic kidney disease (nd-CKD) patients. PARTICIPANTS AND METHODS: This pilot, cross-sectional, and exploratory study evaluated TB cross-sectional images from A-mode US and processed by FIJI-Image J to obtain muscle thickness (MT), echogenicity (EI), cross-sectional area (CSA), pennation angle (PA), and fascicle length (Lf) associating them with absolute HGS by simple and, multiple linear regression. The HGS was normalized to body mass index (BMI) and separated into low HGS (HGS/BMI≤10p according to sex and age) and adequate HGS (HGS/BMI>10p) groups. The body composition was from multifrequency bioimpedance. ROC analysis verified the TB US diagnostic accuracy to low HGS. RESULTS: Were included 42 (21M/21F) adults with 65.5 (60-70) y median age, 47.22% in 3b CKD stage. The low HGS group (45.23%) showed a higher fat mass (FM), TB muscle medium head's PA, and EI than adequate HGS (p<0.05). In crude model, a pixels increase in EI was associated with a 0.452kgf HGS reduction (p=0.019); adjusted for sex, age, and FM, a one-unit increase in EI was associated with a 0.510kgf HGS reduction (p=0.011). The EI also showed moderate diagnostic accuracy (AUC=0.730; CI 95%=0.589; 0.919) to low HGS and a sensitivity of 86.9% (cutoff≥13.52 pixels). CONCLUSION: In nd-CKD patients, of all measurements from US, the EI was the most associated with HGS, and the only one sensitive to low HGS diagnosis.


Subject(s)
Hand Strength , Renal Insufficiency, Chronic , Ultrasonography , Humans , Cross-Sectional Studies , Hand Strength/physiology , Pilot Projects , Male , Female , Renal Insufficiency, Chronic/diagnostic imaging , Renal Insufficiency, Chronic/physiopathology , Aged , Middle Aged , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/physiopathology
6.
Rev. chil. obstet. ginecol. (En línea) ; 89(2): 129-133, abr. 2024. ilus
Article in Spanish | LILACS | ID: biblio-1559728

ABSTRACT

Introducción: El amniocele es una hernia del saco amniótico a través de un defecto en la pared del útero, el cual puede deberse a ruptura uterina, secundario a daños preexistentes, anomalías uterinas o en un útero sin cicatrices. Caso clínico: Presentamos el caso de una paciente de 37 años, con antecedente de dos partos por cesárea, a quien en la semana 25,5 de embarazo se le diagnostica por ecografía amniocele en la pared anterior de útero contenido por la vejiga, además de signos ecográficos de acretismo placentario. La posterior realización de resonancia magnética confirma el diagnóstico. Se realiza manejo expectante con estancia continua intrahospitalaria estricta. Resolución obstétrica a las 34 semanas por cesárea, con extracción fetal por fondo uterino sin complicaciones, con posterior realización de histerectomía con placenta in situ. Conclusiones: Este reporte de caso ilustra la importancia de la identificación temprana de esta condición por ser una complicación infrecuente, pero de grave pronóstico fetomaterno en ausencia de atención inmediata.


Introduction: Amniocele is a hernia of the amniotic sac through a defect in the uterine wall, which can be caused by uterine rupture secondary to preexisting damage, uterine anomalies, or a scarless uterus. Case report: We present a case of a 37-year-old patient with a history of two previous cesarean deliveries. At 25.5 weeks of gestation, the diagnosis of amniocele in the anterior uterine wall, contained by the bladder, along with ultrasound signs of placenta accreta, was confirmed through ultrasound. Subsequent magnetic resonance imaging further confirmed the diagnosis. Expectant management with strict continuous intrahospital stay was implemented. Obstetric resolution was achieved at 34 weeks through cesarean delivery, with uncomplicated fetal extraction through the uterine fundus. Subsequently, a hysterectomy was performed with the placenta left in situ. Conclusions: This case report illustrates the importance of early identification of this condition due to its infrequent but serious feto-maternal prognosis in the absence of immediate attention.


Subject(s)
Humans , Female , Pregnancy , Adult , Placenta Accreta/surgery , Placenta Accreta/diagnostic imaging , Magnetic Resonance Spectroscopy/methods , Cesarean Section/adverse effects , Cesarean Section/methods , Ultrasonography, Prenatal/methods , Hernia/diagnostic imaging
7.
Med Intensiva (Engl Ed) ; 48(3): 165-173, 2024 03.
Article in English | MEDLINE | ID: mdl-38431382

ABSTRACT

Transcranial ultrasonography is a non-invasive, bedside technique that has become a widely implemented tool in the evaluation and management of neurocritically ill patients. It constitutes a technique in continuous growth whose fundamentals (and limitations) must be known by the intensivist. This review provides a practical approach for the intensivist, including the different sonographic windows and planes of insonation and its role in different conditions of the neurocritical patients and in critical care patients of other etiologies.


Subject(s)
Ultrasonography, Doppler, Color , Ultrasonography, Doppler, Transcranial , Humans , Ultrasonography, Doppler, Transcranial/methods , Ultrasonography, Doppler, Color/methods , Ultrasonography , Critical Care
8.
Rehabilitación (Madr., Ed. impr.) ; 58(1): [100822], Ene-Mar, 2024. ilus, tab
Article in Spanish | IBECS | ID: ibc-229690

ABSTRACT

El síndrome del túnel del carpo (STC) es la mononeuropatía por atrapamiento más frecuente; el diagnóstico se establece mediante pruebas electrodiagnósticas con un número sustancial de falsos positivos/negativos. Presentamos la siguiente revisión sistemática, cuyo objetivo es analizar la literatura más reciente en relación con los parámetros ecográficos descritos para estudiar el STC. Seleccionamos estudios que evaluasen parámetros ecográficos en pacientes con sospecha clínica, siguiendo las recomendaciones del manual Cochrane; incluimos revisiones sistemáticas, metaanálisis, estudios caso-control y de pruebas diagnósticas, valorando estudios retrospectivos y revisiones bibliográficas con buena calidad metodológica. La revisión se hizo de artículos publicados entre 2005-2019. Incluimos 8 artículos (2 revisiones sistemáticas/metaanálisis, 2 estudios caso-control, un estudio de pruebas diagnósticas, 2 revisiones literarias y un estudio retrospectivo). Los parámetros analizados fueron el área de sección transversa del nervio mediano, el índice muñeca-antebrazo, el índice entrada-salida, el rango de adelgazamiento del nervio mediano, el abombamiento del retináculo flexor y la vascularización/movilidad. La evidencia actual permite afirmar que la ecografía tiene utilidad en el cribado del STC.(AU)


Carpal tunnel syndrome (CTS) is the most common entrapment mononeuropathy; the diagnosis is established by electrodiagnostic tests with until 34% of false positives/negatives. We present the following systematic review which objective is to analyze the most recent literature related to the ultrasound parameters described to study CTS. We selected studies that evaluated ultrasound parameters in patients with clinical suspicion following the Cochrane manual's recommendations. We include systematic reviews, meta-analyses, case–control studies and diagnostic tests, evaluating retrospective studies and bibliographic reviews with proper methodological quality. Articles published between 2005 and 2019. We included eight articles (two systematic reviews/meta-analyses, two case–control studies, one diagnostic test study, two literature reviews, and one retrospective). The parameters analyzed were cross-sectional area, wrist–forearm index, entry–exit index, thinning range, palmar bowing of the flexor retinaculum, and vascularity/mobility. Current evidence allows us to affirm that ultrasound is useful in screening for CTS.(AU)


Subject(s)
Humans , Male , Female , Carpal Tunnel Syndrome/rehabilitation , Mononeuropathies/diagnostic imaging , Sensitivity and Specificity , Median Nerve/diagnostic imaging , Ultrasonography , Electrodiagnosis
9.
Med. intensiva (Madr., Ed. impr.) ; 48(3): 165-173, Mar. 2024. graf, ilus
Article in Spanish | IBECS | ID: ibc-231022

ABSTRACT

La ultrasonografía transcraneal es una técnica no invasiva y disponible a pie de cama que se ha convertido en una herramienta accesible y consolidada en la evaluación y el manejo clínico de los pacientes neurocríticos. Se trata de una técnica en continuo crecimiento cuyos fundamentos (y sus limitaciones) deben ser conocidos por el intensivista. Esta revisión aporta un enfoque práctico para el intensivista, incluyendo las diferentes ventanas y planos de insonación y su papel en la patología específica propia de los pacientes neurocríticos y en los pacientes críticos de otras etiologías. (AU)


Transcranial ultrasonography is a non-invasive, bedside technique that has become a widely implemented tool in the evaluation and management of neurocritically ill patients. It constitutes a technique in continuous growth whose fundamentals (and limitations) must be known by the intensivist. This review provides a practical approach for the intensivist, including the different sonographic windows and planes of insonation and its role in different conditions of the neurocritical patients and in critical care patients of other etiologies. (AU)


Subject(s)
Humans , Ultrasonography, Doppler, Transcranial/history , Ultrasonography, Doppler, Transcranial/trends , Intensive Care Units , Critical Illness , Ultrasonography , Ultrasonography, Doppler, Duplex , Neurophysiological Monitoring
10.
Rev. Finlay ; 14(1)mar. 2024.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1565162

ABSTRACT

Fundamento: La ultrasonografía del diámetro de la vaina del nervio óptico ha sido utilizada como medidor no invasivo de la presión intracraneal. Una de las deficiencias enunciadas resulta, la no existencia de un valor estándar, que sugiera el límite entre la normalidad y la hipertensión intracraneal. Objetivo: Determinar el diámetro de la vaina del nervio óptico mediante ecografía en voluntarios sanos. Métodos: Se realizó un estudio ecológico de poblaciones múltiples en 160 voluntarios sanos que cumplieron con los criterios de inclusión. Se realizaron 3 mediciones ultrasonográficas en modo B en cada ojo, se tomó como valor final el promedio. Las variables estudiadas fueron: edad, sexo, color de la piel y diámetro de la vaina del nervio óptico. Se calculó el porcentaje, media, mediana, límite y estándar. Con un valor de referencia al 95 % del intervalo de confianza. La relación entre las variables se determinó mediante análisis de regresión logística simple con el paquete estadístico de SPSS 22.0. Resultados: El diámetro de la vaina del nervio óptico, en los sujetos, se cuantificó entre 4,62 - 4,80 mm y 4,66 - 4,83 mm para los ojos derecho e izquierdo respectivamente. Al análisis de regresión lineal simple, solo el sexo se asoció al valor del diámetro de la vaina del nervio óptico (p= 0,000). Conclusiones: En una población de voluntarios sanos el valor del diámetro de la vaina del nervio óptico fue similar a otras descripciones, con diferencias entre el sexo, lo cual sugiere tomar en consideración esta variable al hacer la medición.


Foundation: Ultrasonography of the diameter of the optic nerve sheath has been used as a non-invasive measure of intracranial pressure. One of the deficiencies stated is the non-existence of a standard value that suggests the limit between normality and intracranial hypertension. Objective: Determine the diameter of the optic nerve sheath using ultrasound in healthy volunteers. Methods: A multi-population ecological study was conducted on 160 healthy volunteers who met the inclusion criteria. Three ultrasonographic measurements were performed in B mode in each eye, the average was taken as the final value. The variables studied were: age, sex, skin color and diameter of the optic nerve sheath. The percentage, mean, median, limit and standard were calculated. With a reference value at the 95% confidence interval. The relationship between the variables was determined by simple logistic regression analysis with the SPSS 22.0 statistical package. Results: That diameter of the optic nerve sheath, in the subjects, was quantified between 4.62 - 4.80 mm and 4.66 - 4.83 mm for the right and left eyes respectively. In the simple linear regression analysis, only sex was associated with the value of the diameter of the optic nerve sheath (p= 0.000). Conclusions: In a population of healthy volunteers, the value of the diameter of the optic nerve sheath was similar to other descriptions, with differences between sex, which suggests taking this variable into consideration when making the measurement.

11.
Article in English | MEDLINE | ID: mdl-38354851

ABSTRACT

OBJECTIVE: To determine the precision and accuracy of intraoral sonography in assessing the depth of invasion in oral cancer. MATERIAL AND METHODS: A prospective study was conducted in 30 cases of oral cancer. Subjects were subjected to computerised tomography and intraoral sonography before surgery. The depth of invasion assessed through clinical palpation and radiological tools was compared with surgical histopathology. RESULTS: The depth of invasion assessed on clinical palpation and computerized tomography had statistically significant difference with histopathology whereas intraoral sonography didn't show any difference. The intraoral sonography and computerised tomography had comparable precision and accuracy, with a slight dominance of the computerised tomography in assessing the tumor's depth of invasion greater than 4 mm. However, intraoral sonography was more precise and accurate than computerised tomography in assessing the depth of invasion beyond 10 mm. CONCLUSION: Intraoral sonography was found to be a reliable tool in the assessment of the depth of invasion in oral cancer. It can prove beneficial during surgery in achieving tumour-free surgical margins.

12.
Radiologia (Engl Ed) ; 66(1): 13-22, 2024.
Article in English | MEDLINE | ID: mdl-38365350

ABSTRACT

BACKGROUND AND OBJECTIVE: To determine the operational characteristics of salivary gland ultrasound (SGU) in the diagnosis of Sjögren's syndrome (SS) in a population of colombian patients with dry symptoms. MATERIALS AND METHODS: Study of diagnostic tests in patients with dry symptoms who consecutively attended the rheumatology consultation (2018-2020). Sociodemographic and clinical data were obtained through a survey, paraclinical and ophthalmological tests, minor salivary gland biopsy, unstimulated salivary flow and SGU (score 0-6 based on De Vita) were done. Sensitivity, specificity, positive (PPV) and negative (NPV) predictive values (Stata 15®) were calculated. The receiver operating characteristics (ROC) curve was developed. RESULTS: 102 patients were included (34 SS and 68 non-SS), mean age 55.69 (±11.93) years, 94% women. Positive ultrasound (score of 2 or more) was more frequent in the SS group, (70.6% vs. 22.1%, P<0.0001). The sensitivity was the same for grade 2 and 3 (70.59%), with a higher specificity (89.71%) for grade 3 (PPV 77.42% NPV 85.92). The ROC curve from the sum of the glands by means of ultrasound was better than those of the independent glands. The ROC curve of the ultrasound presented a greater area under the curve (0.72 [0.61-0.82]) than that of the histological analysis (focus score) (0.68 [0.59-0.78]), P=0.0252. CONCLUSION: Salivary gland ultrasound is a useful and reliable method for the classification of SS. Its use could be considered in the future within the SS classification criteria.


Subject(s)
Sjogren's Syndrome , Humans , Female , Middle Aged , Male , Sjogren's Syndrome/diagnostic imaging , Sjogren's Syndrome/pathology , Sensitivity and Specificity , Salivary Glands/diagnostic imaging , Salivary Glands/pathology , Ultrasonography , ROC Curve
13.
Radiología (Madr., Ed. impr.) ; 66(1): 13-22, Ene-Feb, 2024. ilus, tab, graf
Article in Spanish | IBECS | ID: ibc-229642

ABSTRACT

Antecedentes y objetivo: Determinar las características operativas de la ecografía de glándula salival (EGS) en el diagnóstico del síndrome de Sjögren (SS) en una población de pacientes colombianos con síntomas secos. Materiales y métodos: Estudio de pruebas diagnósticas en pacientes con síntomas secos que asistieron a la consulta de reumatología (2018-2020). Se obtuvieron datos sociodemográficos y clínicos a través de una encuesta, pruebas paraclínicas, oftalmológicas, biopsia de glándula salival menor, flujo salival no estimulado y EGS (puntuación 0-6 basada en De Vita). Se calcularon la sensibilidad, la especificidad y los valores predictivos positivo (VPP) y negativo (VPN) (Stata 15®). Se desarrolló la curva de características operativas del receptor (COR). Resultados: Se incluyó a 102 pacientes (34 con SS y 68 sin SS), edad media ± desviación estándar de 55,69 ± 11,93 años, 94% mujeres. La ecografía positiva (puntuación de 2 o más) fue más frecuente en el grupo de SS, (70,6% vs. 22,1%, p < 0,0001). La sensibilidad fue igual para el grado 2 y 3 (70,59%), con una especificidad mayor (89,71%) para el grado 3 (VPP 77,42% VPN 85,92). La curva COR a partir de la sumatoria de las glándulas por medio de ecografía, fue mejor que las de las glándulas independientes. La curva COR de la ecografía presentó una mayor área bajo la curva (0,72 [0,61-0,82]) que la del análisis histológico (puntuación por focos) (0,68 [0,59-0,78]), p = 0,0252. Conclusión: La EGS es un método útil y confiable para la clasificación del SS. Se podría plantear su uso futuro dentro de los criterios clasificatorios del SS.(AU)


Background and objective: To determine the operational characteristics of salivary gland ultrasound (SGU) in the diagnosis of Sjögren's syndrome (SS) in a population of colombian patients with dry symptoms. Materials and methods: Study of diagnostic tests in patients with dry symptoms who consecutively attended the rheumatology consultation (2018-2020). Sociodemographic and clinical data were obtained through a survey, paraclinical and ophthalmological tests, minor salivary gland biopsy, unstimulated salivary flow and SGU (score 0-6 based on De Vita) were done. Sensitivity, specificity, positive (PPV) and negative (NPV) predictive values (Stata 15®) were calculated. The receiver operating characteristics (ROC) curve was developed. Results: 102 patients were included (34 SS and 68 non-SS), mean age 55.69 (± 11.93) years, 94% women. Positive ultrasound (score of 2 or more) was more frequent in the SS group, (70.6% vs. 22.1%, P<.0001). The sensitivity was the same for grade 2 and 3 (70.59%), with a higher specificity (89.71%) for grade 3 (PPV 77.42% NPV 85.92). The ROC curve from the sum of the glands by means of ultrasound was better than those of the independent glands. The ROC curve of the ultrasound presented a greater area under the curve (0.72 [0.61-0.82]) than that of the histological analysis (focus score) (0.68 [0.59-0.78]), P=.0252. Conclusion: Salivary gland ultrasound is a useful and reliable method for the classification of SS. Its use could be considered in the future within the SS classification criteria.


Subject(s)
Humans , Male , Female , Diagnostic Techniques and Procedures , Sjogren's Syndrome/diagnostic imaging , Salivary Glands/diagnostic imaging , Sensitivity and Specificity , Radiology/methods , Diagnostic Imaging , Colombia , Ultrasonography/methods , Prospective Studies
14.
Rev. colomb. cir ; 39(2): 299-307, 20240220. tab
Article in Spanish | LILACS | ID: biblio-1532686

ABSTRACT

Introducción. El aneurisma de la aorta abdominal (AAA) es la dilatación de la aorta abdominal mayor de 1,5 veces el diámetro esperado. Su prevalencia es variable, con tasas reportadas de hasta el 12,5 %. Se considera como causa de muerte de más de 10.000 personas al año en los Estados Unidos. El objetivo de esta revisión de la literatura fue describir los factores de riesgo y las herramientas de tamizaje de AAA. Métodos. Se realizó una búsqueda de la literatura utilizando dos ecuaciones en bases de datos electrónicas, empleando términos seleccionados de "Medical Subject Heading" (MeSH) y "Descriptores en Ciencias de la Salud" (DeCS). Se evaluó la calidad de los estudios con la herramienta STROBE (Strengthening the Reporting of Observational Studies in Epidemiology). Resultados. Se recolectaron 40 artículos y a partir de ellos se construyó el texto de revisión, identificando en estos, los factores de riesgo asociados al desarrollo de AAA, tales como sexo masculino, tabaquismo, hipertensión arterial, antecedente familiar y obesidad, entre otros. La diabetes mellitus parece actuar como factor protector. Dentro de los instrumentos de tamizaje, el ultrasonido abdominal es uno de los más usados. Conclusión. El AAA es una patología multifactorial. En la actualidad la ultrasonografía de aorta es el método de elección para el tamizaje, permitiendo la detección precoz. El tamizaje de AAA con métodos no invasivos, como el ultrasonido, es útil sobre todo en zonas con prevalencia alta de la patología y en pacientes con determinados factores de riesgo.


Introduction. Abdominal aortic aneurysm (AAA) is a dilation of the abdominal aorta greater than 1.5 times the expected diameter. Its prevalence is variable, with reported rates of up to 12.5%. It is considered the cause of death of more than 10,000 people a year in the United States. The objective of this literature review was to describe risk factors and screening tools for AAA. Methods. A literature search was conducted using two equations in electronic databases, using terms selected from "Medical Subject Heading" (MeSH) and "Descriptors in Health Sciences" (DeCS). The quality of the studies was evaluated with the STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) tool. Results. Forty articles were collected and from them the review text was constructed, identifying the risk factors associated with the development of AAA, such as male sex, smoking, high blood pressure, family history and obesity, among others. Diabetes mellitus seems to act as a protective factor. Among the screening instruments, abdominal ultrasound is one of the most used. Conclusion. AAA is a multifactorial pathology. Currently, aortic ultrasonography is the method of choice for screening, allowing early detection. Screening for AAA with non-invasive methods, such as ultrasound, is useful especially in areas with a high prevalence of this pathology and in patients with certain risk factors.


Subject(s)
Humans , Mass Screening , Aortic Aneurysm, Abdominal , Computed Tomography Angiography , Aortic Diseases , Tobacco Use Disorder , Ultrasonography
15.
Int. j. morphol ; 42(1): 71-81, feb. 2024. tab
Article in English | LILACS | ID: biblio-1528835

ABSTRACT

SUMMARY: This paper's aim is a morphometric evaluation of liver and portal vein morphometry using ultrasonography in healthy Turkish population. This study was carried out with 189 subjects (107 females, 82 males). The demographic data and the body surface area were calculated. The longitudinal axis of the liver for two lobes, diagonal axis or liver span, anteroposterior diameter of the liver and portal vein, portal vein transverse diameter, caudate lobe anteroposterior diameter, and portal vein internal diameters as well as longitudinal liver scans in an aortic plane, sagittal plane, transverse plane, and kidney axis were measured. All measurements were analyzed according to age, sex, body mass index, obesity and alcohol consumption. The mean values of the age, height, weight and body mass index were calculated as 44.39 years, 167.05 cm, 74.23 kg, and 27.06kg/m2 in females, respectively. The same values were 44.13 years, 167.70 cm, 75.93 kg and 26.71 kg/m2 in males, respectively. There was significant difference between demographic characteristics, gender, and alcohol consumption in terms of anteroposterior diameter of the liver, portal vein transverse diameter of the right side and liver transverse scan. Also, some measurements including portal vein transverse diameter, liver transverse scan and at kidney axis longitudinal scan of liver showed significant difference between the age groups. There was significant difference in diagonal axis and anteroposterior diameter of liver, portal vein internal diameter, and longitudinal liver scans of the aortic plane parameters between obesity situation. The findings obtained will provide important and useful reference values as it may determine some abnormalities related liver diseases. Also, age, sex, obesity and body mass index values can be effective in the liver and portal vein morphometry related parameters.


El objetivo de este artículo fue realizar una evaluación de la morfometría del hígado y la vena porta mediante ecografía en una población turca sana. Este estudio se llevó a cabo en 189 sujetos (107 mujeres, 82 hombres). Se calcularon los datos demográficos y la superficie corporal. Se midió eleje longitudinal del de dos lóbulos del hígado, el eje diagonal o la extensión del hígado, los diámetros anteroposterior del hígado y de la vena porta, el diámetro transversal de la vena porta, anteroposterior del lóbulo caudado y los diámetros internos de la vena porta, así como las exploraciones longitudinales del hígado en un plano aórtico. Se midieron el plano sagital, el plano transversal y el eje del riñón. Todas las mediciones se analizaron según edad, sexo, índice de masa corporal, obesidad y consumo de alcohol. Los valores medios de edad, talla, peso e índice de masa corporal se calcularon como 44,39 años, 167,05 cm, 74,23 kg y 27,06 kg/m2 en las mujeres, respectivamente. Las mismas variable fueron 44,13 años, 167,70 cm, 75,93 kg y 26,71 kg/m2. Hubo diferencias significativas entre las características demográficas, el sexo y el consumo de alcohol en términos de diámetro anteroposterior del hígado, diámetro transversal de la vena porta del lado derecho y exploración transversal del hígado. Además, algunas mediciones, incluido el diámetro transversal de la vena porta, la exploración transversal del hígado y la exploración longitudinal del hígado en el eje del riñón, mostraron diferencias significativas entre los grupos de edad. Hubo diferencias significativas en el eje diagonal y el diámetro anteroposterior del hígado, el diámetro interno de la vena porta y los parámetros de las exploraciones hepáticas longitudinales del plano aórtico entre situaciones de obesidad. Los hallazgos obtenidos proporcionarán valores de referencia importantes y útiles ya que pueden determinar algunas anomalías relacionadas con enfermedades hepáticas. Además, los valores de edad, sexo, obesidad e índice de masa corporal pueden ser eficaces en los parámetros relacionados con la morfometría del hígado y la vena porta.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Portal Vein/diagnostic imaging , Liver/diagnostic imaging , Portal Vein/anatomy & histology , Reference Values , Turkey , Body Mass Index , Sex Factors , Ultrasonography , Age Factors , Liver/anatomy & histology , Obesity
16.
Rev. colomb. cir ; 39(1): 70-84, 20240102. tab, fig
Article in Spanish | LILACS | ID: biblio-1526809

ABSTRACT

Introducción. La evaluación de la movilidad de las cuerdas vocales en cirugía de tiroides y paratiroides hace parte de la adecuada valoración integral. Aunque la laringoscopia directa es prueba de referencia, su uso real no es rutinario por lo que se propone la ecografía translaríngea como alternativa de evaluación. Métodos. Estudio prospectivo de evaluación de una prueba diagnóstica de la movilidad de las cuerdas vocales pre y posoperatoria, comparando la ecografía translaríngea con la video laringoscopia, en pacientes con cirugía de tiroides y paratiroides, de febrero 1° a noviembre 30 de 2022. Se describieron las variables usando frecuencias absolutas y relativas. En el análisis univariado se calcularon Chi cuadrado y T de Student y en el bivariado, regresión logística binaria. La agudeza diagnóstica se determinó con sensibilidad, especificidad y valores predictivos; se consideró la significancia estadística con p < 0,05. Resultados. Se incluyeron 267 pacientes, 219 mujeres y 48 hombres; 196 pacientes (73,4%) tenían malignidad. Se encontró en el preoperatorio, sensibilidad 100 %, especificidad 99,6 %, VPP 83,3 %, VPN 100 %, odds de probabilidad positiva 83 % y Odds de probabilidad negativa 0,004 %. En el posoperatorio, sensibilidad 82,8 %, especificidad 99,2 %, VPP 92,3 % VPN 97,9 %, odds de probabilidad positiva 92 % y odds de probabilidad negativa 0,2 %. Conclusiones. La ecografía translaríngea en nuestro medio tiene alta agudeza diagnóstica. Podría ser usada en el abordaje inicial de la evaluación de la movilidad de las cuerdas vocales y reemplazar la laringoscopia directa, dejando ésta para cuando la visualización ecográfica no sea adecuada, o en casos de afectación o sospecha de invasión, para su confirmación.


Introduction. The evaluation of the mobility of the vocal cords in thyroid and parathyroid surgery is part of the adequate comprehensive assessment. Altough, direct laryngoscopy is the gold standard, its real use is not routine, so translaryngeal ultrasound approach is proposed as an alternative. Methods. A prospective diagnostic test study was carried out to evaluate the translaryngeal ultrasound compared with video laryngoscopy in visualizing vocal mobility in patients with thyroid and parathyroid surgery from February 1 to November 30, 2022. Patients were described using absolute and relative frequencies. Univariate statistical analysis with Chi-square and Student's t tests. T. Bivariate analysis using binary logistic regression. Diagnostic acuity was calculated with sensitivity, specificity, PPV, NPV. Statistical significance with p< 0.05, 95% confidence interval. Results. 267 patients undergoing thyroid or parathyroid surgery were included, 219 women and 48 men. Malignant: thyroid neoplasm 196 patients (73.4%). The findings were for the preoperative period, 100% sensitivity, 99.6% specificity, PPV 83.33%, NPV 100%, 83% positive probability odds, and 0.004% negative probability odds. For the postoperative period, 82.8% sensitivity, 99.2% specificity, 92.3% PPV, 97.9% NPV, 92% positive probability odds, and 0.2% negative probability odds were found.Conclusions. Translaryngeal ultrasound in our series has high diagnostic acuity. It could be used as the initial approach to evaluate vocal mobility and might replace direct laryngoscopy, leaving it when its visualization is not adequate or in cases of involvement or suspected invasion for confirmation.


Subject(s)
Humans , Thyroid Diseases , Vocal Cords , Diagnostic Imaging , Thyroid Gland , Ultrasonography , Larynx
17.
Rehabilitacion (Madr) ; 58(1): 100822, 2024.
Article in Spanish | MEDLINE | ID: mdl-37864963

ABSTRACT

Carpal tunnel syndrome (CTS) is the most common entrapment mononeuropathy; the diagnosis is established by electrodiagnostic tests with until 34% of false positives/negatives. We present the following systematic review which objective is to analyze the most recent literature related to the ultrasound parameters described to study CTS. We selected studies that evaluated ultrasound parameters in patients with clinical suspicion following the Cochrane manual's recommendations. We include systematic reviews, meta-analyses, case-control studies and diagnostic tests, evaluating retrospective studies and bibliographic reviews with proper methodological quality. Articles published between 2005 and 2019. We included eight articles (two systematic reviews/meta-analyses, two case-control studies, one diagnostic test study, two literature reviews, and one retrospective). The parameters analyzed were cross-sectional area, wrist-forearm index, entry-exit index, thinning range, palmar bowing of the flexor retinaculum, and vascularity/mobility. Current evidence allows us to affirm that ultrasound is useful in screening for CTS.


Subject(s)
Carpal Tunnel Syndrome , Humans , Carpal Tunnel Syndrome/diagnostic imaging , Median Nerve/diagnostic imaging , Retrospective Studies , Sensitivity and Specificity , Ultrasonography
18.
Acta Paul. Enferm. (Online) ; 37: eAPE006722, 2024. tab, graf
Article in Portuguese | LILACS-Express | LILACS, BDENF - Nursing | ID: biblio-1533328

ABSTRACT

Resumo Objetivo Desenvolver uma intervenção de enfermagem com o uso de ultrassonografia de bexiga segundo a Nursing Interventions Classification. Métodos Estudo metodológico em duas etapas: revisão integrativa de literatura e desenvolvimento da intervenção. Para etapa da revisão integrativa de literatura foram investigadas quatro bases de dados (PubMed, CINAHL, LILACS e SCOPUS), incluindo estudos de acesso gratuito e disponíveis na íntegra, nos idiomas inglês, português e espanhol, sem delimitação temporal. Na etapa de desenvolvimento da intervenção, foram seguidas as Diretrizes para Submissão de uma Intervenção à Nursing Interventions Classification Nova ou Revisada. Resultados Na revisão integrativa de literatura foram encontrados 328 estudos primários nas bases de dados, sendo incluídos 17 na análise final. Destacaram-se estudos com delineamento descritivo, sendo prevalente o nível de evidência VI. Os achados possibilitaram desenvolver cada um dos componentes da intervenção de enfermagem (Título, Definição, 17 atividades, Nível de Formação e o Tempo Estimado para realização). Conclusão A Intervenção de Enfermagem intitulada "Ultrassonografia: bexiga" foi desenvolvida, submetida ao Comitê Editorial da Nursing Interventions Classification e aceita para publicação na oitava edição da Classificação.


Resumen Objetivo Desarrollar una intervención de enfermería con el uso de ecografía de vejiga de acuerdo con la Nursing Interventions Classification. Métodos Estudio metodológico en dos etapas: revisión integradora de la literatura y desarrollo de la intervención. Para la etapa de revisión integradora de la literatura se investigó en cuatro bases de datos (PubMed, CINAHL, LILACS y SCOPUS), con la inclusión de estudios de acceso gratuito y disponibles con texto completo, en idioma inglés, portugués y español, sin límite temporal. En la etapa de desarrollo de la intervención, se siguieron las directrices para el envío de una intervención a Nursing Interventions Classification Nueva o Revisada. Resultados En la revisión integradora de la literatura, se encontraron 328 estudios primarios en las bases de datos, de los cuales se incluyeron 17 en el análisis final. Se destacaron los estudios con diseño descriptivo, con prevalencia de nivel de evidencia VI. Los resultados permitieron desarrollar cada uno de los componentes de la intervención de enfermería (título, definición, 17 actividades, nivel de formación y tiempo estimado para la realización). Conclusión La intervención de enfermería titulada "Ecografía: vejiga" fue desarrollada, enviada al Comité Editorial de la Nursing Interventions Classification y aprobada para publicar en la octava edición de la Clasificación.


Abstract Objective To develop a nursing intervention using bladder ultrasound according to the Nursing Interventions Classification. Methods This is a methodological study in two steps: integrative literature review and intervention development. For the integrative literature review step, four databases were investigated (PubMed, CINAHL, LILACS and Scopus), including free access studies available in full, in English, Portuguese and Spanish, without time limits. In the intervention development step, the Guidelines for Submission of a New or Revised Nursing Interventions Classification Intervention were followed. Results In the integrative literature review, 328 primary studies were found in the databases, 17 of which were included in the final analysis. Studies with a descriptive design stood out, with level of evidence VI being prevalent. The findings made it possible to develop each component of the nursing intervention (title, definition, 17 activities, level of training and estimated time for completion). Conclusion The nursing intervention entitled "Ultrasound: bladder" was developed, submitted the Nursing Interventions Classification Editorial Committee and accepted for publication in the 8th edition of the Classification.

19.
Evid. actual. práct. ambul. (En línea) ; 27(1): e007093, 2024. tab
Article in Spanish | LILACS, UNISALUD, BINACIS | ID: biblio-1552247

ABSTRACT

Introducción. Si bien contamos con recomendaciones basadas en la evidencia en contra de realizar tamizaje de cáncer ovárico con ecografía transvaginal debido a que aumenta el riesgo de resultados falsamente positivos y de cascadas diagnósticas, sin disminuir la mortalidad por esta enfermedad, su solicitud en mujeres sanas es frecuente. Sin embargo, no conocemos la magnitud de la implementación de esta práctica, que constituye un cuidado de bajo valor. Objetivo. Documentar el sobreuso de ecografías transvaginales realizadas en forma ambulatoria en un hospital universitario privado de Argentina. Métodos. Estudio de corte transversal de una muestra aleatoria de ecografías realizadas en forma ambulatoria durante 2017 y 2018. Mediante revisión manual de las historias clínicas, la solicitud de cada ecografía fue clasificada como apropiada cuando algún problema clínico justificaba su realización, o inapropiada cuando había sido realizada con fines de control de salud o por una condición clínica sin indicación de seguimiento ecográfico. Resultados. De un total de 1.997 ecografías analizadas, realizadas a 1.954 mujeres adultas (edad promedio 50 años),1.345 (67,4 %; intervalo de confianza [IC] 95 % 65,2 a 69,4) habían sido solicitadas en el contexto de un control de saludo sin un problema asociado en la historia clínica y otras 54 (8,3 %; IC 95 % 6,3 a 10,7), por condiciones de salud para las que no hay recomendaciones de realizar seguimiento ecográfico. Conclusiones. Esta investigación documentó una alta proporción de sobre utilización de la ecografías transvaginales en nuestra institución. Futuras investigaciones permitirán comprender los motivos que impulsan esta práctica y ayudarán a diseñar intervenciones para disminuir estos cuidados de bajo valor. (AU)


Background. Although we have evidence-based recommendations against screening for ovarian cancer with transvaginalultrasound because it increases the risk of false positive results and diagnostic cascades without reducing mortality from this disease, its request in healthy women is frequent. However, we do not know the magnitude of the implementation of this practice, which constitutes low-value care. Objective. To document the overuse of transvaginal ultrasounds performed on an outpatient basis in a private university hospital in Argentina. Methods. Cross-sectional study of a random sample of outpatient ultrasounds performed during 2017 and 2018. Through a manual review of the medical records, the request for each ultrasound was classified as appropriate when a clinical problem justified its performance or inappropriate when it was carried out for health control purposes or for a clinical condition that had no indication for ultrasound follow-up. Results. Of a total of 1997 ultrasounds analyzed, performed on 1954 adult women (average age 50 years), 1,345 (67.4 %;95 % confidence interval [CI] 65.2 to 69.4) had been requested in the context of a health check-up or without a documented problem in the medical history that would support its performance, and another 54 (8.3 %; 95 % CI 6.3 to 10.7), for health conditions for which there are no treatment recommendations to perform ultrasound follow-up. Conclusions. This research documented a high proportion of overuse of transvaginal ultrasound in our institution. Future research will allow us to understand the reasons that drive this practice and will help design interventions to reduce thislow-value care. (AU)


Subject(s)
Humans , Female , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Ovarian Neoplasms/prevention & control , Vagina/diagnostic imaging , Ultrasonography/statistics & numerical data , Medical Overuse/statistics & numerical data , Low-Value Care , Ovarian Neoplasms/diagnostic imaging , Argentina , Mass Screening , Simple Random Sampling , Cross-Sectional Studies , Electronic Health Records , Medical Overuse/prevention & control
SELECTION OF CITATIONS
SEARCH DETAIL