Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 35.890
Filter
1.
Chemistry ; : e202402153, 2024 Jul 14.
Article in English | MEDLINE | ID: mdl-39004609

ABSTRACT

Efficient recognition and extraction of hazardous anionic pollutants from water medium is of great significance for environmental concerns, representing a challenging area of research in supramolecular chemistry. In this study, we present, for the first time, a comprehensive demonstration of the ability of chalcogen bonding (ChB) to recognize and remove the ReO4- from 100% water medium. The anion recognition ability is well elucidated through solution phase NMR and ITC studies, which clearly reveal the selective binding of ReO4- over other oxo-anions. Moreover, the selenoimidazolium scaffold effectively engages in Se•••O ChB interaction with ReO4- as confirmed by X-ray crystal structure and XPS analysis. More importantly, the binding of ReO4- with different prolongations of the σ-holes, along with Se•••Se chalcogen bonding interactions, lead to the formation of a 1D supramolecular assembly. Eventually, ChB receptor Se4Me-Br exhibits ~62% ReO4- extraction efficiency through precipitation as the extraction method. Furthermore, in efforts to enhance efficiency, a hydrophobic ChB receptor Se4Do-PF6 has been prepared, achieving an efficiency of up to ~93% at a very low concentration (~5ppm) by liquid-liquid extraction.

2.
Methods Mol Biol ; 2839: 43-52, 2024.
Article in English | MEDLINE | ID: mdl-39008247

ABSTRACT

Characterizing the two- and three-dimensional distribution of trace metals in biological specimens is key to better understand their role in biological processes. Iron (Fe) is of particular interest in these trace metals due to its widespread role in maintaining cellular health and preventing disease. X-ray fluorescence microscopy (XFM) is emerging as the method of choice for investigators to interrogate the cellular and subcellular distribution of Fe. XFM utilizes the intrinsic X-ray fluorescence properties of each element to produce quantitative 2D and 3D distributions of trace metals within a sample. Herein, methods for sample preparation of cells and tissue for the determination of Fe distribution by XFM are described.


Subject(s)
Iron , Microscopy, Fluorescence , Iron/analysis , Iron/metabolism , Microscopy, Fluorescence/methods , Animals , Humans , Spectrometry, X-Ray Emission/methods , X-Rays
3.
Macromol Rapid Commun ; : e2400307, 2024 Jul 10.
Article in English | MEDLINE | ID: mdl-38987897

ABSTRACT

Most nonconventional luminogens enjoy good water solubility and biocompatibility, showing unique application prospects in fields like biological imaging. Although clustering-triggered emission (CTE) mechanisms have been proposed to explain such emissions, it has not been thoroughly elucidated, which limits their development and application. Herein, the photoluminescence properties of polyacrylamide prepared by reversible addition-fragmentation chain transfer (RAFT) polymerization aqueous solution are utilized to further investigate the effects of changes in concentration, in order to elucidate the emission mechanism through transmission electron microscopy (TEM), small angle X-ray scattering (SAXS) and theoretical calculation. The results showed that the size distribution, morphology, and distance between the polymer clusters formed in the water solution are successfully correlated with the cluster emission centers. The emission mechanism of nonconventional luminogens solutions is more clearly and intuitively elucidated, which has a promoting effect on the emission and application of this field. It provides a strategy a strategy to clarify the CTE mechanism of nonconventional luminogens solution more clearly.

4.
Eur Spine J ; 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38980367

ABSTRACT

OBJECTIVE: To compare the differences between Ultrasound Volume Navigation (UVN), O-arm Navigation, and conventional X-ray fluoroscopy-guided screw placement in Minimally Invasive Transforaminal Lumbar Interbody Fusion (MIS-TLIF) surgeries. METHODS: A total of 90 patients who underwent MIS-TLIF due to lumbar disc herniation from January 2022 to January 2023 were randomly assigned to the UVN group, O-arm group, and X-ray group. UVN, O-arm navigation, and X-ray guidance were used for screw placement in the respective groups, while the remaining surgical procedures followed routine MIS-TLIF protocols. Intraoperative data including average single screw placement time, total radiation dose, and average effective radiation dose per screw were recorded and calculated. On the 10th day after surgery, postoperative X-ray and CT examinations were conducted to assess screw placement accuracy and facet joint violation. RESULTS: There were no significant differences in general characteristics among the three groups, ensuring comparability. Firstly, the average single screw placement time in the O-arm group was significantly shorter than that in the UVN group and X-ray group (P<0.05). Secondly, in terms of total radiation dose during surgery, for single-level MIS-TLIF, the O-arm group had a significantly higher radiation dose compared to the UVN group and X-ray group (P<0.05). However, for multi-level MIS-TLIF, the X-ray group had a significantly higher radiation dose than the O-arm group and UVN group (P<0.05). In terms of average single screw radiation dose, the O-arm group and X-ray group were similar (P>0.05), while the UVN group was significantly lower than the other two groups (P<0.05). Furthermore, no significant differences were found in screw placement assessment grades among the three groups (P>0.05). However, in terms of facet joint violation rate, the UVN group (10.3%) and O-arm group (10.7%) showed no significant difference (P>0.05), while the X-ray group (26.7%) was significantly higher than both groups (P<0.05). Moreover, in the UVN group, there were significant correlations between average single screw placement time and placement grade with BMI index (r = 0.637, P<0.05; r = 0.504, P<0.05), while no similar significant correlations were found in the O-arm and X-ray groups. CONCLUSION: UVN-guided screw placement in MIS-TLIF surgeries demonstrates comparable efficiency, visualization, and accuracy to O-arm navigation, while significantly reducing radiation exposure compared to both O-arm navigation and X-ray guidance. However, UVN may be influenced by factors like obesity, limiting its application.

5.
J Imaging Inform Med ; 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38980623

ABSTRACT

Malposition of a nasogastric tube (NGT) can lead to severe complications. We aimed to develop a computer-aided detection (CAD) system to localize NGTs and detect NGT malposition on portable chest X-rays (CXRs). A total of 7378 portable CXRs were retrospectively retrieved from two hospitals between 2015 and 2020. All CXRs were annotated with pixel-level labels for NGT localization and image-level labels for NGT presence and malposition. In the CAD system, DeepLabv3 + with backbone ResNeSt50 and DenseNet121 served as the model architecture for segmentation and classification models, respectively. The CAD system was tested on images from chronologically different datasets (National Taiwan University Hospital (National Taiwan University Hospital)-20), geographically different datasets (National Taiwan University Hospital-Yunlin Branch (YB)), and the public CLiP dataset. For the segmentation model, the Dice coefficients indicated accurate delineation of the NGT course (National Taiwan University Hospital-20: 0.665, 95% confidence interval (CI) 0.630-0.696; National Taiwan University Hospital-Yunlin Branch: 0.646, 95% CI 0.614-0.678). The distance between the predicted and ground-truth NGT tips suggested accurate tip localization (National Taiwan University Hospital-20: 1.64 cm, 95% CI 0.99-2.41; National Taiwan University Hospital-Yunlin Branch: 2.83 cm, 95% CI 1.94-3.76). For the classification model, NGT presence was detected with high accuracy (area under the receiver operating characteristic curve (AUC): National Taiwan University Hospital-20: 0.998, 95% CI 0.995-1.000; National Taiwan University Hospital-Yunlin Branch: 0.998, 95% CI 0.995-1.000; CLiP dataset: 0.991, 95% CI 0.990-0.992). The CAD system also detected NGT malposition with high accuracy (AUC: National Taiwan University Hospital-20: 0.964, 95% CI 0.917-1.000; National Taiwan University Hospital-Yunlin Branch: 0.991, 95% CI 0.970-1.000) and detected abnormal nasoenteric tube positions with favorable performance (AUC: 0.839, 95% CI 0.807-0.869). The CAD system accurately localized NGTs and detected NGT malposition, demonstrating excellent potential for external generalizability.

6.
Genes Dev ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38960718

ABSTRACT

As part of the efforts to understand nuclear IκB function in NF-κB-dependent gene expression, we report an X-ray crystal structure of the IκBζ ankyrin repeat domain in complex with the dimerization domain of the NF-κB p50 homodimer. IκBζ possesses an N-terminal α helix that conveys domain folding stability. Affinity and specificity of the complex depend on a small portion of p50 at the nuclear localization signal. The model suggests that only one p50 subunit supports binding with IκBζ, and biochemical experiments confirm that IκBζ associates with DNA-bound NF-κB p50:RelA heterodimers. Comparisons of IκBζ:p50 and p50:κB DNA complex crystallographic models indicate that structural rearrangement is necessary for ternary complex formation of IκBζ and p50 with DNA.

7.
Article in English | MEDLINE | ID: mdl-39004899

ABSTRACT

The development of perovskite direct X-ray detectors shows potential for advancing medical imaging and industrial inspection precision. To ensure the optimal energy conversion efficiency of X-rays for reducing radiation doses, it is necessary for perovskites with thicknesses reaching hundreds of micrometers or even several millimeters to be utilized. However, the nonlinear current response becomes uncertain with such high thicknesses. For instance, the prevailing theory regarding the rapid trapping and release of charges by shallow-level defects falls short in explaining the nonlinear current response observed in high-quality single-crystal samples. Moreover, a significant nonlinear current response can degrade the detection performance. Here, we elucidate peculiar parasitic and drift capacitance-induced nonlinear current responses in perovskites, which arise from bulk structural deficiencies and interface junction width variation in addition to shallow-level defects. Both theoretical analysis and experimental findings demonstrate the effective suppression of nonlinear current responses by establishing bulk heterojunctions and refining interface junctions. Consequently, we have successfully developed highly linear current-responsive detectors based on polycrystalline MAPbI3 thick films. Notably, these detectors achieve a record sensitivity of 2.3 × 104 µC·Gyair-1·cm-2 under 100 kVp X-ray irradiation with a low bias of 0.1 V/µm, enabling enduring and high-resolution X-ray imaging for high-density objects. Successful fabrication and testing of a 64 × 64-pixel flat-panel prototype detector affirm the widespread applicability of these strategies in rectifying nonlinear current responses in perovskite-based X-ray detectors.

9.
Am J Transl Res ; 16(6): 2453-2463, 2024.
Article in English | MEDLINE | ID: mdl-39006261

ABSTRACT

BACKGROUND: Percutaneous Endoscopic Lumbar Discectomy (PELD) has emerged as routine treatment for lumbar disc herniation (LDH) due to its minimal invasiveness and quick recovery. However, PELD demands high precision from the surgeon, as the risk of intraoperative complications is substantial, including potential damage to the nerve root and dura, and a higher likelihood of recurrence post-surgery. Thus, preoperative planning utilizing CT and MRI imaging is essential. METHODS: In this study, the clinical data of 140 patients treated with PELD for LDH from January 2021 to December 2023 were retrospectively analyzed. Patients were categorized into two groups based on whether CT and MRI registration (CMR) was employed for surgical planning: a CMR group (n=68) and a control group (n=72). Data collected included surgery time, hospital stay duration, and scores from the Visual Analog Scale (VAS) for low back and leg pain, as well as the Japanese Orthopaedic Association Lumbar Spine Score (JOA). Differences between the two groups were assessed using the Student's t-test. RESULTS: No significant difference was found in hospital stay length between the groups (P=0.277). Surgery time was significantly shorter in the CMR group (P<0.001). Prior to surgery, no significant differences in VAS scores for leg and low back pain were observed between the groups (P=0.341 and P=0.131, respectively); however, at 2 months postoperatively, both scores were significantly lower in the CMR group (P<0.001 and P=0.002, respectively). Similarly, no difference in preoperative JOA scores was noted (P=0.750), but at 2 months postoperative, the CMR group exhibited significantly higher scores (P<0.001). CONCLUSION: Compared with the traditional PELD, the preoperative use of CMR has shown to reduce surgery time, alleviate leg and low back pain, and increase the lumbar JOA score at 2 months after surgery, underscoring its efficacy in enhancing surgical outcomes.

10.
J Orthop Res ; 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39007705

ABSTRACT

This study investigates the automated detection of enchondromas, benign cartilage tumors, from x-ray images using deep learning techniques. Enchondromas pose diagnostic challenges due to their potential for malignant transformation and overlapping radiographic features with other conditions. Leveraging a data set comprising 1645 x-ray images from 1173 patients, a deep-learning model implemented with Detectron2 achieved an accuracy of 0.9899 in detecting enchondromas. The study employed rigorous validation processes and compared its findings with the existing literature, highlighting the superior performance of the deep learning approach. Results indicate the potential of machine learning in improving diagnostic accuracy and reducing healthcare costs associated with advanced imaging modalities. The study underscores the significance of early and accurate detection of enchondromas for effective patient management and suggests avenues for further research in musculoskeletal tumor detection.

11.
J Synchrotron Radiat ; 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39007823

ABSTRACT

StreamSAXS is a Python-based small- and wide-angle X-ray scattering (SAXS/WAXS) data analysis workflow platform with graphical user interface (GUI). It aims to provide an interactive and user-friendly tool for analysis of both batch data files and real-time data streams. Users can easily create customizable workflows through the GUI to meet their specific needs. One characteristic of StreamSAXS is its plug-in framework, which enables developers to extend the built-in workflow tasks. Another feature is the support for both already acquired and real-time data sources, allowing StreamSAXS to function as an offline analysis platform or be integrated into large-scale acquisition systems for end-to-end data management. This paper presents the core design of StreamSAXS and provides user cases demonstrating its utilization for SAXS/WAXS data analysis in offline and online scenarios.

12.
J Synchrotron Radiat ; 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39007825

ABSTRACT

The ID10 beamline of the SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) synchrotron light source in Jordan was inaugurated in June 2023 and is now open to scientific users. The beamline, which was designed and installed within the European Horizon 2020 project BEAmline for Tomography at SESAME (BEATS), provides full-field X-ray radiography and microtomography imaging with monochromatic or polychromatic X-rays up to photon energies of 100 keV. The photon source generated by a 2.9 T wavelength shifter with variable gap, and a double-multilayer monochromator system allow versatile application for experiments requiring either an X-ray beam with high intensity and flux, and/or a partially spatial coherent beam for phase-contrast applications. Sample manipulation and X-ray detection systems are designed to allow scanning samples with different size, weight and material, providing image voxel sizes from 13 µm down to 0.33 µm. A state-of-the-art computing infrastructure for data collection, three-dimensional (3D) image reconstruction and data analysis allows the visualization and exploration of results online within a few seconds from the completion of a scan. Insights from 3D X-ray imaging are key to the investigation of specimens from archaeology and cultural heritage, biology and health sciences, materials science and engineering, earth, environmental sciences and more. Microtomography scans and preliminary results obtained at the beamline demonstrate that the new beamline ID10-BEATS expands significantly the range of scientific applications that can be targeted at SESAME.

13.
J Colloid Interface Sci ; 675: 660-669, 2024 Jul 06.
Article in English | MEDLINE | ID: mdl-38991280

ABSTRACT

The global rise in obesity necessitates innovative weight loss strategies. Naturally occurring smectite clays, such as montmorillonite (MMT), offer promise due to their unique properties that interfere with free fatty acid (FFA) liberation, reducing systemic uptake. However, the mechanisms of MMT-FFA interactions and their implications for weight management are undefined. This study investigates these interactions by adding MMT (10 % w/w) to in vitro lipolysis media containing medium chain triglycerides (MCTs), and monitoring FFA liberation using pH-stat titration. Nanoparticle tracking analysis (NTA) and synchrotron-based small-angle X-ray scattering (sSAXS) observed time-dependent structural changes, while electron microscopy examined clay morphology during digestion. A 35 % reduction in FFA liberation occurred after 25 min of digestion with MCT + MMT, with digestion kinetics following a biphasic model driven by calcium soap formation. NTA revealed a 17-fold decrease in vesicular structures with MCT + MMT, and sSAXS highlighted a rapid lamellar phase evolution linked to calcium soap formation. This acceleration is attributed to MMT's adsorption to unionized FFAs via hydrogen bonding, supported by TEM images showing a decrease in d-spacing, indicating FFA intercalation is not the main adsorption mechanism. These findings highlight MMT's potential as a novel intervention for reducing dietary lipid absorption in obesity and metabolic diseases.

14.
Insights Imaging ; 15(1): 174, 2024 Jul 12.
Article in English | MEDLINE | ID: mdl-38992307

ABSTRACT

OBJECTIVES: This study aimed to identify factors influencing in-hospital mortality in adult patients with active vascular contrast extravasation (AVCE) on abdominopelvic computed tomography (CT). METHODS: All consecutive patients with AVCE detected on CT between January 2019 and May 2022 were retrospectively included. Their data were compared through uni- and multivariable analyses between patients with and without in-hospital mortality. Path analysis was utilized to clarify the relationships among factors affecting mortality. RESULTS: There were 272 patients (60.2 ± 19.4 years, 150 men) included, of whom 70 experienced in-hospital mortality. Multivariable analysis revealed nonsurgery, chronic kidney disease (CKD) stage 4-5 or dialysis, prolonged partial thromboplastin time (PTT), minimum AVCE length > 8 mm, and a lower rate of packed red cell (PRC) transfusion were identified as independent predictors of in-hospital mortality (p = 0.005-0.048). Path analysis demonstrated direct influences of CKD4-5 or dialysis, prolonged PTT, and minimum AVCE length on mortality (coefficients 0.525-0.616; p = 0.009 to < 0.001). PRC transfusion impacted mortality through nonsurgery (coefficient 0.798, p = 0.003) and intensive care unit (ICU) admission (coefficients 0.025, p = 0.016), leading to subsequent death. Three AVCE spaces (free, loose, and tight) defined on CT were not directly associated with in-hospital mortality. CONCLUSION: In adults with AVCE on CT, AVCE size had a direct independent influence on mortality, highlighting the critical role of radiologists in detecting and characterizing this finding. Additionally, CKD4-5 or dialysis and prolonged PTT also directly influenced mortality, while the lower rate of PRC transfusion impacted mortality through nonsurgery and ICU admission. CLINICAL RELEVANCE STATEMENT: In patients with active vascular contrast extravasation (AVCE) on abdominopelvic CT, larger AVCE directly increased in-hospital mortality. Radiologists' detection and characterization of this finding is crucial, along with recognizing factors like CKD4-5, dialysis, and prolonged PTT to improve patient outcomes. KEY POINTS: Several factors independently predicted in-hospital mortality in patients with abdominopelvic AVCE. Extravasation length > 8 mm was the only imaging marker predictive of in-hospital mortality. Non-imaging factors correlated with in-hospital mortality, and PRC transfusion impacted mortality through nonsurgery and ICU admission pathways.

15.
J Biol Chem ; : 107547, 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38992441

ABSTRACT

RNA thermometers are temperature-sensing non-coding RNAs that regulate the expression of downstream genes. A well-characterized RNA thermometer motif discovered in bacteria is the ROSE-like element (repression of heat shock gene expression). ATP-binding cassette (ABC) transporters are a superfamily of transmembrane proteins that harness ATP hydrolysis to facilitate the export and import of substrates across cellular membranes. Through structure-guided bioinformatics, we discovered that ROSE-like RNA thermometers are widespread upstream of ABC transporter genes in bacteria. X-ray crystallography, biochemistry, and cellular assays indicate that these RNA thermometers are functional regulatory elements. This study expands the known biological role of RNA thermometers to these key membrane transporters.

16.
Article in English | MEDLINE | ID: mdl-38993025

ABSTRACT

Metal halide perovskites have demonstrated superior sensitivity, lower detection limits, stability, and exceptional photoelectric properties in comparison to existing commercially available X-ray detector materials, showing their potential for shaping the next generation of X-ray detectors. Nevertheless, significant challenges persist in the seamless integration of these materials into pixelated array sensors for large-area X-ray direct detection imaging. In this article, we propose a strategy for fabricating large-scale array devices using a double-sided bonding process. The approach involves depositing a wet film on the surface of a thin-film transistor substrate to establish a robust bond between the substrate and δ-CsPbI3 wafer via van der Waals force, thereby facilitating area-array imaging. Additionally, the freestanding polycrystalline δ-CsPbI3 wafer demonstrated a competitive ultralow detection limit of 3.46 nGyair s-1 under 50 kVP X-ray irradiation, and the δ-CsPbI3 wafer still maintains a stable signal output (signal current drift is 3.5 × 10-5 pA cm-1 s-1 V-1) under the accumulated radiation dose of 234.9 mGyair. This strategy provides a novel perspective for the industrial production of large-area X-ray flat panel detectors utilizing perovskites and their derivatives.

17.
Eur J Radiol Open ; 13: 100578, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38993285

ABSTRACT

Purpose: Traditional CT acquisition planning is based on scout projection images from planar anterior-posterior and lateral projections where the radiographer estimates organ locations. Alternatively, a new scout method utilizing ultra-low dose helical CT (3D Landmark Scan) offers cross-sectional imaging to identify anatomic structures in conjunction with artificial intelligence based Anatomic Landmark Detection (ALD) for automatic CT acquisition planning. The purpose of this study is to quantify changes in scan length and radiation dose of CT examinations planned using 3D Landmark Scan and ALD and performed on next generation wide volume CT versus examinations planned using traditional scout methods. We additionally aim to quantify changes in radiation dose reduction of scans planned with 3D Landmark Scan and performed on next generation wide volume CT. Methods: Single-center retrospective analysis of consecutive patients with prior CT scan of the same organ who underwent clinical CT using 3D Landmark Scan and automatic scan planning. Acquisition length and dose-length-product (DLP) were collected. Data was analyzed by paired t-tests. Results: 104 total CT examinations (48.1 % chest, 15.4 % abdomen, 36.5 % chest/abdomen/pelvis) on 61 individual consecutive patients at a single center were retrospectively analyzed. 79.8 % of scans using 3D Landmark Scan had reduction in acquisition length compared to the respective prior acquisition. Median acquisition length using 3D Landmark Scan was 26.7 mm shorter than that using traditional scout methods (p < 0.001) with a 23.3 % median total radiation dose reduction (245.6 (IQR 150.0-400.8) mGy cm vs 320.3 (IQR 184.1-547.9) mGy cm). CT dose index similarly was overall decreased for scans planned with 3D Landmark and ALD and performed on next generation CT versus traditional methods (4.85 (IQR 3.8-7) mGy vs. 6.70 (IQR 4.43-9.18) mGy, respectively, p < 0.001). Conclusion: Scout imaging using reduced dose 3D Landmark Scan images and Anatomic Landmark Detection reduces acquisition range in chest, abdomen, and chest/abdomen/pelvis CT scans. This technology, in combination with next generation wide volume CT reduces total radiation dose.

18.
Cureus ; 16(6): e62186, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38993415

ABSTRACT

INTRODUCTION: Reported prevalence rates of the fabella sesamoid bone vary widely, particularly between studies based on either X-ray imaging or anatomical dissection approaches. The purpose of this study was to directly compare these two methodologies in their detection of fabellae and investigate whether variability in the density of fabellae could explain any discrepancies. METHODS: Fifty cadaveric knee segments were examined for the presence of a fabella by both X-ray imaging and anatomical dissection. The relative density of each excised fabella specimen was then quantified using a separate set of radiographs.  Results: Fabellae were detected in 40% of the sample knees via a manual dissection approach but in just 12% of those same specimens using X-ray imaging. Relative density measurements confirmed that fabellae identifiable only via dissection were significantly less dense than fabellae visible in whole knee radiographs but denser than the surrounding tissue. CONCLUSION: Radiology cannot reliably detect cartilaginous or incompletely ossified fabellae, which were found in 28% of the study population. Clinicians should consider the potential occurrence of a fabella when diagnosing posterolateral knee pain, even if it may not be visible via X-ray.

19.
Radiol Bras ; 57: e20230114, 2024.
Article in English | MEDLINE | ID: mdl-38993957

ABSTRACT

Objective: To conduct a survey on the use of the term "interstitial lung abnormalities" in radiology reports in Brazil, propose an appropriate Portuguese-language translation for the term, and provide a brief review of the literature on the topic. Materials and Methods: A survey was sent via electronic message to various radiologists in Brazil, asking about their familiarity with the term, which translation of the term they use in Portuguese, and whether they use the criteria proposed by the Fleischner Society. Results: A total of 163 responses were received, from all regions of Brazil. Although the vast majority (88%) of the respondents stated that they were familiar with the term "interstitial lung abnormalities", there was considerable variation regarding the equivalent term they used in Portuguese. Conclusion: We suggest that the term "anormalidades pulmonares intersticiais" be used in order to standardize radiology reports and disseminate knowledge of these findings in Brazil.


Objetivo: Fazer um levantamento sobre o uso do termo interstitial lung abnormalities nos laudos radiológicos no Brasil, propor uma tradução para o termo e fazer uma breve revisão sobre o tema. Materiais e Métodos: Foi enviada uma pesquisa, por meio de mensagem eletrônica, para diversos radiologistas de todo o Brasil, questionando sobre a familiarização com o termo, qual tradução em português utilizam e se usam os critérios propostos pela diretriz da Sociedade Fleischner. Resultados: Foram recebidas 163 respostas de todas as regiões do Brasil e a grande maioria dos radiologistas respondeu estar familiarizado com o termo interstitial lung abnormalities (88%), mas houve grande variação em relação ao termo utilizado como tradução para o português. Conclusão: Sugerimos a padronização do termo "anormalidades pulmonares intersticiais", a fim de uniformizar os relatórios radiológicos e difundir esta entidade no País.

20.
Radiol Bras ; 57: e20230124, 2024.
Article in English | MEDLINE | ID: mdl-38993963

ABSTRACT

Although kidney transplantation is the best therapeutic option for patients with chronic kidney disease, the immunosuppression required greatly increases susceptibility to infections that are responsible for high post-transplant mortality. Pulmonary tuberculosis (TB) represents a major cause of such infections, and its early diagnosis is therefore quite important. In view of that, we researched the manifestations of active pulmonary TB in kidney transplant recipients, through chest X-ray and computed tomography (CT), as well as determining the number of cases of active pulmonary TB occurring over a 3.5-year period at our institution. We identified four cases of active pulmonary TB in kidney transplant recipients. The CT scans provided information complementary to the chest X-ray findings in all four of those cases. We compared our CT findings with those reported in the literature. We analyzed our experience in conjunction with an extensive review of the literature that was nevertheless limited because few studies have been carried out in lowand middle-income countries, where the incidence of TB is higher.


Apesar de o transplante renal ser a melhor opção terapêutica para pacientes com doença renal crônica, a imunodepressão decorrente desse tratamento eleva muito a suscetibilidade desses pacientes a infecções, responsáveis por altas taxas de mortalidade pós-operatórias. A tuberculose (TB) pulmonar é uma significativa causa dessas infecções, sendo muito importante o seu diagnóstico precoce. Assim, nós pesquisamos as manifestações da TB pulmonar ativa nessa população de transplantados renais por meio de radiografias simples e tomografia computadorizada (TC) do tórax, também para estabelecer o número de casos de TB pulmonar ativa em nossa instituição após levantamento de 3,5 anos. Encontramos quatro casos de TB pulmonar ativa em pacientes transplantados renais. A TC forneceu informações adicionais em relação às radiografias de tórax em 100% dos casos analisados. Comparamos os nossos achados de TC com os relatados na literatura. Somamos a experiência obtida com extensa revisão da literatura, ainda limitada nessa questão, com poucos estudos realizados em países em desenvolvimento onde a incidência de TB é maior.

SELECTION OF CITATIONS
SEARCH DETAIL
...