Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 49
Filter
1.
Circ Cardiovasc Interv ; 17(6): e012827, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38818724

ABSTRACT

Coronary obstruction (CO) is a rare but critical complication of transcatheter aortic valve implantation. It is associated with significant morbidity and mortality. This comprehensive review elucidates the evolving landscape of CO risk assessment and management strategies in the contemporary era of transcatheter aortic valve implantation. Drawing upon recent advances in computed tomography angiography, we delve into the nuanced evaluation of anatomic parameters crucial for predicting CO risk. Furthermore, this review explores the utility of interventional and surgical techniques, including chimney stenting and leaflet modification systems, in mitigating CO complications. In summary, this review serves as a practical guide for clinicians navigating the complexities of CO prevention and management in the evolving landscape of transcatheter aortic valve implantation, with the goal of optimizing patient outcomes and ensuring procedural success.


Subject(s)
Aortic Valve Stenosis , Coronary Occlusion , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/etiology , Coronary Occlusion/therapy , Treatment Outcome , Risk Factors , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Risk Assessment , Stents , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Coronary Angiography , Heart Valve Prosthesis , Computed Tomography Angiography
2.
Cardiovasc Revasc Med ; 65: 75-80, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38565427

ABSTRACT

Transcatheter heart valve (THV) procedures require careful planning and consideration to prevent coronary artery obstruction (CAO), which poses a significant and potentially life-threatening condition, especially in patients undergoing valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR). Despite identifying predictors of CAO and utilization of computed tomography and inputting THV features, a significant uncertainty remains in predicting CAO. The ShortCut™ device (Pi-Cardia, Rehovot, Israel) was purposefully designed to modify the leaflets in patients undergoing TAVR, especially prior to ViV procedures, to overcome the risk for CAO. This review aims to detail the device's objectives, structure, procedural steps, the available clinical data, and future directions for its intended utilization in the structural arena for the prevention of CAO.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Coronary Occlusion , Heart Valve Prosthesis , Prosthesis Design , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Treatment Outcome , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/prevention & control , Coronary Occlusion/etiology , Coronary Occlusion/therapy , Risk Factors , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology
3.
J Cardiothorac Surg ; 19(1): 143, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38504317

ABSTRACT

BACKGROUND: Coronary artery obstruction after percutaneous aortic replacement is a complication with high short-term mortality secondary to the lack of timely treatment. There are various predictors of coronary obstruction prior to valve placement such as the distance from the ostia, the degree of calcification, the distance from the sinuses; In such a situation some measures must be taken to prevent and treat coronary obstruction. CASE PRESENTATION: An 84-year-old male, with severe aortic stenosis and high surgical risk, who was treated with TAVR. However, during the deployment of the valve he presented hemodynamic instability secondary to LMCA obstruction. The intravascular image showed obstruction of the ostium secondary to the displacement of calcium that he was successfully treated with a chimney stent technique. CONCLUSIONS: The high degree of calcification and the left ostium near the annulus are conditions for obstruction of the ostium at the time of valve release; In this context, provisional stenting prior to TAVR in patients at high risk of obstruction should be considered as a safe prevention strategy to achieve the success of the procedure.


Subject(s)
Aortic Valve Stenosis , Calcinosis , Coronary Occlusion , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Male , Humans , Aged, 80 and over , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/surgery , Coronary Vessels/surgery , Heart Valve Prosthesis/adverse effects , Risk Factors , Treatment Outcome , Coronary Occlusion/etiology , Calcinosis/complications , Calcinosis/surgery , Aortic Valve Stenosis/complications , Prosthesis Design
4.
J Cardiothorac Surg ; 19(1): 128, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38491358

ABSTRACT

BACKGROUND: Acute coronary artery obstruction is a rare but lethal complication of surgical aortic valve replacement (SAVR), which may be caused by embolization of resected native tissue such as calcium plaque, thrombus, or perivalvular aortic tissue like fat embolus. Coronary artery bypass grafting (CABG) and percutaneous coronary intervention (PCI) are the main treatment modalities. PCI is less invasive, but it is difficult to determine its feasibility intraoperatively. CASE PRESENTATION: We report an 86-year-old woman who had asymptomatic severe aortic stenosis. She had scleroderma with an intractable left leg ulcer and bilateral leg varices. Considering the possibility of the spread of infection from the leg wound, SAVR was performed via right anterior thoracotomy to avoid complications such as mediastinitis. Coronary artery occlusion was suspected after weaning of cardiopulmonary bypass in the operation room due to asynergy with ST elevation and new severe mitral regurgitation. Transoesophageal echocardiography (TEE) helped diagnose coronary obstruction by embolus based on the degree of stenosis and the movement of the stenosis site. Percutaneous catheter intervention was performed successfully to restore coronary perfusion. CONCLUSION: TEE facilitated the diagnosis of coronary artery stenosis caused by an embolus and helped in determining the feasibility of percutaneous catheter intervention, thus allowing us to choose PCI over CABG as a less invasive surgery. This is especially invaluable in cases where obtaining a saphenous graft for CABG is difficult or where CABG would have required conversion from minimally invasive surgery (anterolateral approach) to median sternotomy.


Subject(s)
Aortic Valve Stenosis , Coronary Artery Disease , Embolism , Percutaneous Coronary Intervention , Aged, 80 and over , Female , Humans , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Constriction, Pathologic/complications , Coronary Artery Disease/surgery , Decision Making , Embolism/complications , Iatrogenic Disease , Treatment Outcome
5.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1024422

ABSTRACT

Transcatheter aortic valve replacement(TAVR)is currently one of the main therapeutic strategies for aortic valve disease.Preoperative imaging assessment is crucial for operation project planning and prevention of procedure-associated complications.Different from planar image reconstruction,3D printing technology can accurately depict the anatomical structure of the aortic root.It enables further assessment of operative risk and therapeutic strategy through in vitro simulation,especially for assessing the risk of coronary artery obstruction and planning interventional procedures.Here,we report on two patients who underwent a 3D printing aortic root anatomical simulation model,followed an by in vitro balloon dilatation/valve implantation test,to evaluate the risk of coronary artery obstruction suggested by CT angiography planar image reconstruction before TAVR.

6.
Front Cardiovasc Med ; 10: 1270782, 2023.
Article in English | MEDLINE | ID: mdl-38111894

ABSTRACT

The chimney technique has been utilized to minimize the risk of coronary artery obstruction during valve-in-valve procedures. Here, we present a case involving an 89-year-old female patient with low coronary ostia, severe aortic regurgitation, and intractable heart decompensation caused by degenerated aortic bioprosthesis. The patient underwent a successful transcatheter aortic valve implantation procedure using the chimney technique in both coronary ostia.

7.
Life (Basel) ; 13(7)2023 Jul 21.
Article in English | MEDLINE | ID: mdl-37511980

ABSTRACT

Due to technological advancements during the past 20 years, transcatheter aortic valve replacements (TAVRs) have significantly improved the treatment of symptomatic and severe aortic stenosis, significantly improving patient outcomes. The continuous evolution of transcatheter valve models, refined imaging planning for enhanced accuracy, and the growing expertise of technicians have collectively contributed to increased safety and procedural success over time. These notable advancements have expanded the scope of TAVR to include patients with lower risk profiles as it has consistently demonstrated more favorable outcomes than surgical aortic valve replacement (SAVR). As the field progresses, coronary angiography is anticipated to become increasingly prevalent among patients who have previously undergone TAVR, particularly in younger cohorts. It is worth noting that aortic stenosis is often associated with coronary artery disease. While the task of re-accessing coronary artery access following TAVR is challenging, it is generally feasible. In the context of valve-in-valve procedures, several crucial factors must be carefully considered to optimize coronary re-access. To obtain successful coronary re-access, it is essential to align the prosthesis with the native coronary ostia. As part of preventive measures, strategies have been developed to safeguard against coronary obstruction during TAVR. One such approach involves placing wires and non-deployed coronary balloons or scaffolds inside an at-risk coronary artery, a procedure known as chimney stenting. Additionally, the bioprosthetic or native aortic scallops intentional laceration to prevent iatrogenic coronary artery obstruction (BASILICA) procedure offers an effective and safer alternative to prevent coronary artery obstructions. The key objective of our study was to evaluate the techniques and procedures employed to achieve commissural alignment in TAVR, as well as to assess the efficacy and measure the impact on coronary re-access in valve-in-valve procedures.

8.
Nursing (Ed. bras., Impr.) ; 26(300): 9616-9624, ju.2023. tab.
Article in English, Portuguese | LILACS, BDENF - Nursing | ID: biblio-1443498

ABSTRACT

Objetivo: Identificar práticas clínicas com resultados favoráveis aos pacientes com diagnóstico de infarto agudo do miocárdio sem obstrução de artéria coronária. Método: Revisão integrativa da literatura pela base de dados National Library of Medicine e Biblioteca Virtual de Saúde de estudos publicados entre 2018 e 2022. Resultados:87,5% dos estudos encontrados destacaram estratégias farmacológicas e destes, 62,5% citaram o uso da dupla antiagregaçãoplaquetária como mais utilizada, apesar de nenhum estudo evidenciar benefícios. Os inibidores do sistema renina-angiotensina-aldosterona comprovaram benefícios em três estudos. 75% dos artigos apontaram que esse grupo de pacientes recebem menos medicamentos preventivos comparados aos pacientes com infarto por obstrução coronariana. Outros seis estudos, revelaram condução clínica variável desses pacientes. Conclusão: O uso de inibidores do sistema renina-angiotensina-aldosterona deve ser considerado por ser a única medicação com redução da mortalidade evidenciada. São necessários estudos maiores para orientar com mais segurança à condução do infarto do miocárdio sem obstrução de coronária.(AU)


Objective: To identify clinical practices with favorable results for patients diagnosed with acute myocardial infarction without coronary artery obstruction. Method: Integrative literature review using the National Library of Medicine and Virtual Health Library databases of studies published between 2018 and 2022. Results: 87.5% of the studies found highlighted pharmacological strategies and of these, 62.5% cited the use of dual antiplatelet therapy as the most used, despite no study showing benefits. Inhibitors of the renin-angiotensin-aldosterone system have shown benefits in three studies. 75% of the articles pointed out that this group of patients receive less preventive medication compared to patients with infarction due to coronary obstruction. Another six studies revealed variable clinical management of these patients. Conclusion: The use of renin-angiotensin-aldosterone system inhibitors should be considered as it is the only medication with proven reduction in mortality. Larger studies are needed to guide with more safety the management of myocardial infarction without coronary obstruction.(AU)


Objetivo: Identificar prácticas clínicas con resultados favorables para pacientes con diagnóstico de infarto agudo de miocardio sin obstrucción arterial coronaria. Método: revisión integrativa de la literatura utilizando las bases de datos de la Biblioteca Nacional de Medicina y la Biblioteca Virtual en Salud de estudios publicados entre 2018 y 2022. Resultados: el 87,5% de los estudios encontrados destacaron estrategias farmacológicas y de estos, el 62,5% citó el uso de la terapia antiplaquetaria dual como el más utilizados, a pesar de que ningún estudio muestra beneficios. Los inhibidores del sistema renina-angiotensina-aldosterona han mostrado beneficios en tres estudios. El 75% de los artículos señalaron que este grupo de pacientes recibe menos medicación preventiva en comparación con los pacientes con infarto por obstrucción coronaria. Otros seis estudios revelaron un manejo clínico variable de estos pacientes. Conclusión: Se debe considerar el uso de inhibidores del sistema renina-angiotensina-aldosterona, ya que es el único medicamento con reducción comprobada de la mortalidad. Son necesarios estudios más amplios que orienten con mayor seguridad el manejo del infarto de miocardio sin obstrucción coronaria.(AU)


Subject(s)
Therapeutics , Homeopathic Therapeutic Approaches , Clinical Decision-Making , MINOCA , Myocardial Infarction
9.
Eur J Cardiothorac Surg ; 64(2)2023 08 01.
Article in English | MEDLINE | ID: mdl-37140552

ABSTRACT

OBJECTIVES: The aim of this study was to more accurately predict the optimal pulmonary artery (PA) reconstruction procedure (Lecompte manoeuvre or original Jatene procedure) during the arterial switch operation, we focused on the horizontal sectioning (HS) angle between the left hilum PA and the great arteries using preoperative computed tomography imaging. METHODS: We defined the HS angle α (ß) as the angle between the tangential line from the posterior (anterior) wall of the left PA at the hilum to the left anterior (right posterior) surface of the main PA and the tangential line from the left surface of the ascending aorta to the left anterior (right posterior) surface of the main PA. We identified 14 consecutive patients diagnosed with transposition of the great arteries or transposition of the great artery-type double-outlet right ventricle who underwent preoperative computed tomography imaging. The original Jatene or Lecompte procedure was used for 9 (OJ group) and 5 (L group) patients. Relationships of the great arteries of the OJ and L groups were side by side in 8 and 2 patients, oblique in 1 and 1 patient and anteroposterior in 0 and 2 patients, respectively. RESULTS: In the OJ group, ß was greater than α in all patients. The median α/ß value was 0.618. In group L, α was greater than ß in all patients. The median α/ß was 1.307. Left PA stenosis caused by stretching was not observed in the L group. Coronary obstruction was not identified in the OJ group. Left PA stenosis behind the neo-ascending aorta was observed in 1 patient in the OJ group and required reoperation. CONCLUSIONS: The HS angle may be a useful predictor of optimal intraoperative PA reconstruction during arterial switch operation, especially for side-by-side or oblique relationships.


Subject(s)
Arterial Switch Operation , Transposition of Great Vessels , Humans , Infant , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/surgery , Transposition of Great Vessels/diagnostic imaging , Transposition of Great Vessels/surgery , Constriction, Pathologic , Aorta/diagnostic imaging , Aorta/surgery
10.
J Thorac Cardiovasc Surg ; 166(4): e130-e141, 2023 10.
Article in English | MEDLINE | ID: mdl-37086238

ABSTRACT

BACKGROUND: Leaflet thrombosis after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR) may be caused by blood flow stagnation in the native and neosinus regions. To date, aortic leaflet laceration has been used to mitigate coronary obstruction following TAVR; however, its influence on the fluid mechanics of the native and neosinus regions is poorly understood. This in vitro study compared the flow velocities and flow patterns in the setting of SAVR vs TAVR with and without aortic leaflet lacerations. METHODS: Two valves, (23-mm Perimount and 26-mm SAPIEN 3; Edwards Lifesciences) were studied in a validated mock flow loop under physiologic conditions. Neosinus and native sinus fluid mechanics were quantified using particle image velocimetry in the left and noncoronary cusp, with an increasing number of aortic leaflets lacerated or removed. RESULTS: Across all conditions, SAVR had the highest average sinus and neosinus velocities, and this value was used as a reference to compare against the TAVR conditions. With an increasing number of leaflets lacerated or removed with TAVR, the average sinus and neosinus velocities increased from 25% to 70% of SAVR flow (100%). Diastolic velocities were substantially augmented by leaflet laceration. Also, the shorter frame of the SAVR led to higher flow velocities compared with the longer frame of the TAVR, even after complete leaflet removal. CONCLUSIONS: Leaflet laceration augmented TAVR native and neosinus flow fields, approaching that of SAVR. These findings may have potential clinical implications for the use of single or multiple leaflet lacerations to reduce leaflet thrombosis and thus potentially improve TAVR durability.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Lacerations , Thrombosis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Lacerations/complications , Lacerations/surgery , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Thrombosis/etiology , Aortic Valve Stenosis/surgery , Treatment Outcome
11.
J Surg Case Rep ; 2023(1): rjac603, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36636654

ABSTRACT

Transesophageal echocardiography (TEE) has become an indispensable part of cardiac surgery, but its potential for assessing coronary anatomy and blood flow remains underutilised. This case report presents a case of acute iatrogenic left main coronary artery obstruction following re-operative aortic valve replacement that was promptly diagnosed by intraoperative TEE and managed successfully by Bentall operation. We also emphasise the technique of TEE for coronary evaluation, its caveats and its clinical application during cardiac surgery.

13.
JACC Cardiovasc Interv ; 16(1): 94-102, 2023 01 09.
Article in English | MEDLINE | ID: mdl-36599593

ABSTRACT

BACKGROUND: Coronary artery obstruction is a life-threatening complication of transcatheter aortic valve replacement (TAVR) procedures. Current preventive strategies are suboptimal. OBJECTIVES: The aim of this study was to describe bench testing and clinical experience with a novel device that splits valve leaflets that are at risk for causing coronary obstruction after TAVR, allowing normal coronary flow. METHODS: The ShortCut device was initially tested in vitro and preclinically in a porcine model for functionality and safety. The device was subsequently offered to patients at elevated risk for coronary obstruction. Risk for coronary obstruction was based on computed tomography-based anatomical characteristics. Procedure success was determined as patient survival at 30 days with a functioning new valve, without stroke or coronary obstruction. RESULTS: Following a successful completion of bench testing and preclinical trial, the device was used in 8 patients with failed bioprosthetic valves (median age 81 years; IQR: 72-85 years; 37.5% man) at 2 medical centers. A total of 11 leaflets were split: 5 patients (63.5%) were considered at risk for left main obstruction alone, and 3 patients (37.5%) were at risk for double coronary obstruction. All patients underwent successful TAVR without evidence of coronary obstruction. All patients were discharged from the hospital in good clinical condition, and no adverse neurologic events were noted. Procedure success was 100%. CONCLUSIONS: Evaluation of the first dedicated transcatheter leaflet-splitting device shows that the device can successfully split degenerated bioprosthetic valve leaflets. The procedure was safe and successfully prevented coronary obstruction in patients at risk for this complication following TAVR.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Coronary Occlusion , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Male , Humans , Swine , Animals , Aged, 80 and over , Heart Valve Prosthesis/adverse effects , Risk Factors , Prosthesis Failure , Treatment Outcome , Bioprosthesis/adverse effects , Prosthesis Design , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/etiology , Coronary Occlusion/prevention & control , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications
14.
Article in English | MEDLINE | ID: mdl-36468494

ABSTRACT

Coronary artery obstruction is a life-threatening complication of transcatheter aortic valve replacement procedures, and current preventive strategies are suboptimal. The novel ShortCut device splits bioprosthetic valve leaflets that are at risk of causing coronary artery obstruction after transcatheter aortic valve implantation, allowing for normal coronary flow. In this video tutorial, we demonstrate a valve-in-valve transcatheter aortic valve implantation using a dedicated leaflet-splitting device for prevention of coronary artery obstruction in transcatheter aortic valve replacement.


Subject(s)
Transcatheter Aortic Valve Replacement , Humans , Coronary Vessels , Catheters
15.
J Am Heart Assoc ; 11(16): e023663, 2022 08 16.
Article in English | MEDLINE | ID: mdl-35912709

ABSTRACT

Background Methamphetamine misuse affects 27 million people worldwide and is associated with cardiovascular disease (CVD); however, risk factors for CVD among users have not been well studied. Methods and Results We studied hospitalized patients in California, captured by the Healthcare Cost and Utilization Project database, between 2005 and 2011. We studied the association between methamphetamine use and CVD (pulmonary hypertension, heart failure, stroke, and myocardial infarction). Among 20 249 026 persons in the Healthcare Cost and Utilization Project, 66 199 used methamphetamines (median follow-up 4.58 years). Those who used were more likely younger (33 years versus 45 years), male (63.3% versus 44.4%), smoked, misused alcohol, and had depression and anxiety compared with nonusers. Methamphetamine use was associated with the development of heart failure (hazard ratio [HR], 1.53 [95% CI, 1.45-1.62]) and pulmonary hypertension (HR, 1.42 [95% CI, 1.26-1.60]). Among users, male sex (HR, 1.73 [95% CI, 1.37-2.18]) was associated with myocardial infarction. Chronic kidney disease (HR, 2.38 [95% CI, 1.74-3.25]) and hypertension (HR, 2.26 [95% CI, 2.03-2.51]) were strong risk factors for CVD among users. When compared with nonuse, methamphetamine use was associated with a 32% significant increase in CVD, alcohol abuse with a 28% increase, and cocaine use with a 47% increase in CVD. Conclusions Methamphetamine use has a similar magnitude of risk of CVD compared with alcohol and cocaine. Prevention and treatment could be focused on those with chronic kidney disease, hypertension, and mental health disorders.


Subject(s)
Cardiovascular Diseases , Cocaine , Heart Failure , Hypertension, Pulmonary , Hypertension , Methamphetamine , Myocardial Infarction , Renal Insufficiency, Chronic , Cardiovascular Diseases/etiology , Heart Failure/complications , Humans , Hypertension/complications , Hypertension, Pulmonary/complications , Male , Methamphetamine/adverse effects , Myocardial Infarction/complications , Renal Insufficiency, Chronic/complications , Risk Factors
17.
Heart Views ; 23(1): 1-9, 2022.
Article in English | MEDLINE | ID: mdl-35757448

ABSTRACT

Background: Transcatheter aortic valve in valve (Aviv) replacement has been shown to be an effective therapeutic option in patients with failed aortic bioprosthetic valves. This review intended to evaluate contemporary 1-year outcomes of Aviv in recent studies. Methods: A systematic review on outcomes of Aviv was performed using the best available evidence from studies obtained using a MEDLINE, Cochrane database, and SCOPUS search. Endpoints of interest were survival, coronary artery obstruction, prosthesis-patient mismatch (PPM), stroke, pacemaker implantation, and structural valve deterioration. Results: A total of 3339 patients from 23 studies were included. Mean age was 68-80 years, 20%-50% were female, and Society of Thoracic Surgeons score ranged from 5.7 to 31.1. Thirty-day all-cause mortality ranged from 2% to 8%, and 1-year all-cause mortality ranged from 8% to 33%. Coronary artery obstruction risk after Aviv ranged from 0.6% to 4%. One-year stroke ranged from 2% to 8%. Moderate-severe PPM occurred in 11%-58%, and pacemaker rate at 1 year ranged from 5% to 12%. Conclusion: Transcatheter aortic ViV has emerged as an effective therapeutic option to treat patients with failed bioprostheses. The acceptable complication rate and favorable 1-year outcomes make Aviv an appropriate alternative to redo surgical aortic valve replacement.

19.
Heart Lung Circ ; 31(8): 1134-1143, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35365428

ABSTRACT

BACKGROUND: Current imaging techniques may inadequately rule out coronary artery obstruction (CAO), a potentially fatal complication during transcatheter aortic valve replacement (TAVR). Advancements in three-dimensional (3D)-printing allow the development of models capable of replicating cardiac anatomy and predicting CAO. We sought to simulate TAVR utilising 3D-printed cardiac models to improve CAO risk assessment and procedural safety. METHODS: Thirteen (13) patients with aortic stenosis at high-risk of CAO during TAVR were selected for 3D-printed modelling. The relevant anatomy for TAVR was precisely reconstructed with Materialise Heart Print-Flex (Materialse, Leuven, Belgium) technology. An appropriately sized valve prosthesis was deployed in each 3D-model and coronary ostia assessed for obstruction. RESULTS: Model-derived results were compared to clinical outcomes in 13 cases. One high-risk case underwent TAVR resulting in left main obstruction and subsequent stenting. This outcome was accurately predicted by the 3D-model simulation. Two (2) high-risk TAVR cases were abandoned following transient CAO during balloon aortic valvuloplasty (BAV). The 3D-model simulations correlated with these findings, demonstrating CAO either by a calcium nodule or the native valve leaflet. In another two cases, BAV was uncertain, however the 3D-simulation demonstrated patency and successful TAVR was undertaken. In remaining cases, no obstruction was demonstrated in-vitro, and all underwent uncomplicated TAVR. CONCLUSIONS: In this proof-of-concept study, 3D-model TAVR simulation correlates well to clinical outcomes. 3D-models of patients at high-risk of CAO may be utilised in pre-procedural planning to accurately predict this complication. As lower-risk surgical cohorts are considered for TAVR, 3D-models may minimise complications leading to safer patient outcomes.


Subject(s)
Aortic Valve Stenosis , Coronary Occlusion , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Coronary Occlusion/surgery , Coronary Vessels/surgery , Heart Valve Prosthesis/adverse effects , Humans , Printing, Three-Dimensional , Prosthesis Design , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
20.
J Clin Med ; 10(23)2021 Nov 26.
Article in English | MEDLINE | ID: mdl-34884239

ABSTRACT

Transcatheter aortic valve implantation (TAVI) to manage structural bioprosthetic valve deterioration has been successful in mitigating the risk of a redo cardiac surgery. However, TAVI-in-TAVI is a complex intervention, potentially associated with feared complications such as coronary artery obstruction. Coronary obstruction risk is especially high when the previously implanted prosthesis had supra-annular leaflets and/or the distance between the prosthesis and the coronary ostia is short. The BASILICA technique (bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction) was developed to prevent coronary obstruction during native or valve-in-valve interventions but has now also been considered for TAVI-in-TAVI interventions. Despite its utility, the technique requires a not so widely available toolbox. Herein, we discuss the TAVI-in-TAVI BASILICA technique and how to perform it using more widely available tools, which could spread its use.

SELECTION OF CITATIONS
SEARCH DETAIL