Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 239
Filter
1.
Int J Cardiol ; : 132450, 2024 Aug 13.
Article in English | MEDLINE | ID: mdl-39147282

ABSTRACT

BACKGROUND: Drug-coated balloon (DCB) angioplasty and drug-eluting stents (DES) are two widely used treatments for in-stent restenosis (ISR). Focal and non-focal types of ISR affect the clinical outcomes. The present study aims to compare DES reimplantation versus DCB angioplasty in acute coronary syndrome (ACS) patients with focal ISR and non-focal ISR lesions. METHODS: Patients with ISR lesions underwent percutaneous coronary intervention (PCI) were retrospectively evaluated and divided into DES group and DCB group. The primary endpoint was the incidence of target lesion failure (TLF) at 24 months follow up. Propensity score matching (PSM) was conducted to balance the baseline characteristics. RESULTS: For focal ISR, TLF was comparable in the DES and DCB groups at 24 months of follow-up (Before PSM, hazard ratio [HR]: 0.70; 95% confidence interval [CI]: 0.39-1.27; p = 0.244; After PSM, HR: 0.83; 95% CI: 0.40-1.73; p = 0.625). For non-focal ISR, TLF was significantly decreased in DES compared with DCB group (Before PSM, HR: 0.43; 95% CI: 0.29-0.63; p < 0.001; After PSM, HR: 0.33; 95% CI: 0.19-0.59; p < 0.001), which was mainly attributed to the lower incidence of clinically indicated target lesion revascularization (CD-TLR) (Before PSM, HR: 0.39; 95% CI: 0.26-0.59; p < 0.001; After PSM, HR: 0.28; 95% CI: 0.15-0.54; p < 0.001). CONCLUSIONS: The clinical outcomes for DES and DCB treatment are similar in focal type of ISR lesions. For non-focal ISR, the treatment of DES showed a significant decrease in TLF which was mainly attributed to a lower incidence of CD-TLR.

2.
J Endovasc Ther ; : 15266028241267759, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-39148336

ABSTRACT

PURPOSE: Clinical trials have demonstrated that high-dose drug-coated balloon (HD-DCB) and polymer-based drug-eluting stent (PB-DES) treatments for femoropopliteal (FP) artery disease have favorable outcomes. However, which one would be better remained unrevealed. METHODS: This study used the databases of 2 large-scale multicenter prospective drug-coated balloon (DCB) and drug-eluting stent (DES) registries. The study included 2470 patients with symptomatic FP lesion treated with IN.PACT Admiral DCB or Eluvia DES at 69 centers. A propensity-score-based paired analysis was conducted. Primary endpoint was 1-year restenosis rate. Secondary endpoints were 1-year reocclusion rate, target lesion revascularization (TLR), acute thrombosis, bypass conversion, major amputation, major adverse limb event (MALE), and all-cause death. RESULTS: A total of 1535 patients were treated with HD-DCB, and 935 patients were treated with PB-DES. The propensity-score matching extracted 678 pairs, with no remarkable intergroup difference in baseline characteristics. The 1-year restenosis rate was significantly lower in the PB-DES group than in the HD-DCB group (16.0% vs 22.0%, p=0.016). The other endpoints (reocclusion rate, TLR, acute thrombosis, bypass conversion, major amputation, MALE, and all-cause death) did not differ between the groups. No baseline characteristics had any significant interaction effect on the association of HD-DCB vs PB-DES with restenosis risk (all p>0.05). CONCLUSIONS: This study demonstrated that the 1-year TLR, reocclusion rate, and other endpoints did not differ between the PB-DES group and the HD-DCB group despite the lower restenosis in the PB-DES group. CLINICAL IMPACT: One-year restenosis rate was significantly lower in the polymer-based DES group than in the high-dose DCB group for foemoropopliteal disease. However, there is no difference in the other endpoints between two groups.

3.
Med ; 2024 Aug 10.
Article in English | MEDLINE | ID: mdl-39153473

ABSTRACT

BACKGROUND: Patients with ST-elevation myocardial infarction (STEMI) tend to be excluded or under-represented in randomized clinical trials evaluating the effects of potent P2Y12 inhibitor monotherapy after short-term dual antiplatelet therapy (DAPT). METHODS: Individual patient data were pooled from randomized clinical trials that included STEMI patients undergoing drug-eluting stent (DES) implantation and compared ticagrelor monotherapy after short-term (≤3 months) DAPT versus ticagrelor-based 12-month DAPT in terms of centrally adjudicated clinical outcomes. The co-primary outcomes were efficacy outcome (composite of all-cause death, myocardial infarction, or stroke) and safety outcome (Bleeding Academic Research Consortium type 3 or 5 bleeding) at 1 year. FINDINGS: The pooled cohort contained 2,253 patients with STEMI. The incidence of the primary efficacy outcome did not differ between the ticagrelor monotherapy group and the ticagrelor-based DAPT group (1.8% versus 2.0%; hazard ratio [HR] = 0.88; 95% confidence interval [CI] = 0.49-1.61; p = 0.684). There was no difference in cardiac death between the groups (0.6% versus 0.7%; HR = 0.89; 95% CI = 0.32-2.46; p = 0.822). The incidence of the primary safety outcome was significantly lower in the ticagrelor monotherapy group (2.3% versus 4.0%; HR = 0.56; 95% CI = 0.35-0.92; p = 0.020). No heterogeneity of treatment effects was observed for the primary outcomes across subgroups. CONCLUSIONS: In patients with STEMI treated with DES implantation, ticagrelor monotherapy after short-term DAPT was associated with lower major bleeding without an increase in the risk of ischemic events compared with ticagrelor-based 12-month DAPT. Further research is necessary to extend these findings to non-Asian patients. FUNDING: This study was funded by Biotronik (Bülach, Switzerland).

4.
Int J Cardiol ; : 132436, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-39153511

ABSTRACT

INTRODUCTION: Percutaneous coronary intervention (PCI) with drug-eluting stents (DES) in complex coronary artery disease (CAD) has been established as the standard of care, but stent-related events are not uncommon. Sirolimus-Coated Balloon (SCB)-based angioplasty is an emerging technology, although it needs to be thoroughly evaluated compared with DES in the complex PCI setting. This study aimed to investigate the safety and efficacy of SCB-based angioplasty compared with new-generation DES in complex PCI. METHODS: Net adverse cardiovascular events (NACE: all-cause death, target lesion revascularization, non-fatal myocardial infarction, and major bleedings according to BARC classification), as a primary study endpoint was compared between SCB and new-generation DES for complex coronary lesions. RESULTS: Among 1782 patients with complex CAD, 1076 were treated with a sirolimus-coated balloon (EASTBOURNE Registry) and 706 with new-generation DES (COMPLEX Registry). After propensity score matching, a total of 512 patients in both groups were analyzed. NACE occurred more significantly in the DES group during the 1-year follow-up (10.5% vs. 3.9%, p = 0.003), mainly due to a higher risk of bleeding (6.6% vs. 0.4%, p = 0.001). The Cox model adjusted for lesion length showed a significantly lower hazard of NACE (HR: 0.23, CI [0.10, 0.52], p < 0.001) and all-cause mortality (HR: 0.07, CI [0.01, 0.66], p = 0.020) in SCB compared to DES group. CONCLUSIONS: SCB angioplasty has an advantage over DES for the treatment of complex CAD regarding NACE, significantly reducing the incidence of major bleeding without increasing ischemic endpoints. SCB may be an alternative to DES in selected patients with complex coronary lesions.

5.
Int J Gen Med ; 17: 3443-3452, 2024.
Article in English | MEDLINE | ID: mdl-39139709

ABSTRACT

Objective: This study aims to investigate their correlation and predictive utility for in-stent restenosis (ISR) in patients with acute coronary syndrome (ACS) following percutaneous coronary intervention (PCI). Methods: We collected medical records of 668 patients who underwent PCI treatment from January 2022 to December 2022. Based on follow-up results (ISR defined as luminal narrowing ≥ 50% on angiography), all participants were divided into ISR and non-ISR groups. The XGBoost machine learning (ML) model was employed to identify the optimal predictive variables from a set of 31 variables. Discriminatory ability was evaluated using the area under the receiver operating characteristic (ROC) curve (AUC), while calibration and performance of the prediction models were assessed using the Hosmer-Lemeshow (HL) test and calibration plots. Clinical utility of each model was evaluated using decision curve analysis (DCA). Results: In the XGBoost importance ranking of predictive factors, LMR and RC ranked first and fourth, respectively. The AUC of the entire XGBoost ML model was 0.8098, whereas the model using traditional stepwise backward regression, comprising five predictive factors, had an AUC of 0.706. The XGBoost model showed superior predictive performance with a higher AUC, indicating better discrimination and predictive accuracy for ISR compared to traditional methods. Conclusion: LMR and RC are identified as cost-effective and reliable biomarkers for predicting ISR risk in ACS patients following drug-eluting stent (DES) implantation. LMR and RC represent cost-effective and reliable biomarkers for predicting ISR risk in ACS patients following drug-eluting stent implantation. Enhances the accuracy and clinical utility of ISR prediction models, offering clinicians a robust tool for risk stratification and personalized patient management.

6.
JACC Cardiovasc Interv ; 17(15): 1825-1836, 2024 Aug 12.
Article in English | MEDLINE | ID: mdl-39142758

ABSTRACT

BACKGROUND: In patients with in-stent restenosis (ISR) bioresorbable vascular scaffolds (BVS) provide similar results to drug-coated balloons (DCBs) but are inferior to drug-eluting stents (DES) at 1 year. However, the long-term efficacy of BVS in these patients remains unknown. OBJECTIVES: This study sought to assess the long-term safety and efficacy of BVS in patients with ISR. METHODS: RIBS VI (Restenosis Intrastent: Bioresorbable Vascular Scaffolds Treatment; NCT02672878) and RIBS VI Scoring (Restenosis Intrastent: Bioresorbable Vascular Scaffolds Treatment With Scoring Balloon; NTC03069066) are prospective multicenter studies designed to evaluate the results of BVS in patients with ISR (N = 220). The inclusion and exclusion criteria were identical to those used in the RIBS IV (ISR of DES) (Restenosis Intra-stent of Drug-eluting Stents: Drug-eluting Balloon vs Everolimus-eluting Stent; NCT01239940) and RIBS V (ISR of bare-metal stents) (Restenosis Intra-stent of Bare Metal Stents: Paclitaxel-eluting Balloon vs Everolimus-eluting Stent; NCT01239953) randomized trials (including 249 ISR patients treated with DCBs and 249 ISR patients treated with DES). A prespecified comparison of the long-term results obtained with these treatment modalities (ie, DES, DCBs, and BVS) was performed. RESULTS: Clinical follow-up at 3 years was obtained in all (100%) 718 patients. The 3-year target lesion revascularization rate after BVS was 14.1% (vs 12.9% after DCBs [not significant], and 5.2% after DES [HR: 2.80; 95% CI: 1.47-5.36; P = 0.001]). In a landmark analysis (>1 year), the target lesion revascularization rate after BVS was higher than after DES (adjusted HR: 3.41; 95% CI: 1.15-10.08) and DCBs (adjusted HR: 3.33; 95% CI: 1.14-9.70). Very late vessel thrombosis was also more frequent with BVS (BVS: 1.8%, DCBs: 0.4%, DES: 0%; P = 0.03). CONCLUSIONS: In patients with ISR, late clinical results of DES are superior to those obtained with DCBs and BVS. Beyond the first year, DCBs are safer and more effective than BVS.


Subject(s)
Absorbable Implants , Coronary Restenosis , Prosthesis Design , Humans , Time Factors , Male , Treatment Outcome , Female , Prospective Studies , Coronary Restenosis/etiology , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/therapy , Middle Aged , Aged , Risk Factors , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/adverse effects , Cardiovascular Agents/administration & dosage , Cardiovascular Agents/adverse effects , Stents , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/adverse effects , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Coated Materials, Biocompatible , Drug-Eluting Stents , Randomized Controlled Trials as Topic
8.
JACC Asia ; 4(7): 519-531, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39101114

ABSTRACT

Background: There are limited clinical data on drug-coated balloon (DCB)-based percutaneous coronary intervention (PCI) compared with drug-eluting stent (DES)-only PCI in patients with complex coronary artery lesions. Objectives: The goal of the current study was to investigate the efficacy of DCB in patients undergoing PCI for complex coronary artery lesions. Methods: From an institutional registry of patients with de novo complex coronary artery lesions, 126 patients treated with DCB-based PCI were compared with 234 propensity score-matched patients treated with DES-only PCI. Complex coronary artery lesions were defined as the presence of at least 1 of the following: bifurcation, chronic total occlusion, unprotected left main disease, long lesion ≥38 mm, multivessel disease, lesion requiring ≥3 devices, or severe calcification. The primary endpoint was target vessel failure (TVF) at 2 years, a composite of cardiac death, target vessel-related myocardial infarction, and target vessel revascularization. Results: Baseline characteristics were comparable between the 2 groups. DCB-based PCI showed a comparable risk of TVF vs DES-based PCI (7.6% vs 8.1%; HR: 0.81; 95% CI: 0.33-1.99; P = 0.638). The risks of cardiac death (5.0% vs 5.7%; HR: 0.78; 95% CI: 0.24-2.49), target vessel-related myocardial infarction (0.9% vs 1.3%; HR: 2.65; 95% CI: 0.26-27.06), and target vessel revascularization (3.5% vs 2.0%; HR: 1.30; 95% CI: 0.30-5.67) were also comparable between the 2 groups. Conclusions: DCB-based PCI showed comparable risks of TVF vs those of DES-only PCI in patients with complex coronary artery lesions. DCB might be considered as a suitable alternative device to DES in patients undergoing complex PCI. (Long-term Outcomes and Prognostic Factors in Patient Undergoing CABG or PCI; NCT03870815).

9.
Future Cardiol ; : 1-16, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38948932

ABSTRACT

Oral anticoagulation therapy (OAC) is a mainstay for mitigating stroke and other embolic events in patients with atrial fibrillation (AF). Despite the demonstrated efficacy of OAC in reducing events, many patients are unable to tolerate OAC due to bleeding risks. Left atrial appendage occlusion (LAAO) devices were developed as implantable technologies to moderate stroke risk in patients with intolerance to OAC. Despite clinical data supporting near-comparable protection against thromboembolic events with OAC, device-related thrombus formation has emerged as a critical complication following LAAO that remains a potential limitation to the safety and efficacy of LAAO. Improved biocompatibility of LAAO devices with fluoropolymers, a well-established stent-coating technology used to reduce thrombus formation and promote endothelialization, may optimize outcomes after LAAO.


[Box: see text].

10.
Neuroradiology ; 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38977434

ABSTRACT

BACKGROUND: Symptomatic intracranial atherosclerotic stenosis (ICAS) is a major cause of ischemic stroke worldwide. In patients undergoing endovascular treatment for ICAS, in-stent restenosis (ISR) is associated with ischemic stroke recurrence. OBJECTIVE: Intracranial drug-eluting self-expanding stent systems (COMETIU; Sinomed Neurovita Technology Inc., CHN) are new devices for treating ICAS. This study evaluated the perioperative experience and medium-term outcomes of COMETIU in 16 patients. METHODS: We prospectively analyzed 16 patients with ICAS (≥ 70% stenosis) who underwent intravascular therapy between September 4, 2022, and February 1, 2023. The primary outcome was the incidence of ISR at 6 months postoperatively. The secondary efficacy outcomes were device and technical success rates. The secondary safety outcomes included stroke or death within 30 days after the procedure and the cumulative annual rate of recurrent ischemic stroke in the target-vessel territory from 31 days to 6 months and 1 year. RESULTS: A total of 16 patients with 16 intracranial atherosclerotic lesions were treated with 16 COMETIUs. All procedures were performed under general anesthesia with 100% device and technical success rates, with no cases of periprocedural stroke or death. The mean radiographic follow-up duration was at least 6 months postoperatively, and all patients presented for radiographic and clinical follow-up. There were no reported ischemic or hemorrhagic strokes. Angiographic follow-up for all patients revealed no cases of ISR. CONCLUSION: COMETIU is safe and effective for treating ICAS, with minimal risk during the procedure and a low rate of ISR during medium-term follow-up.

11.
J Cardiothorac Surg ; 19(1): 407, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38951893

ABSTRACT

BACKGROUND: In patients with unprotected left main coronary artery disease (ULMCAD), this study compared the long-term prognosis of drug-eluting stent insertion guided by intravascular ultrasonography (IVUS) vs. angiography. PATIENTS AND METHODS: This retrospective consort investigation was performed in December 2021. This analysis included 199 patients who underwent IVUS-guided (IVUS group, n = 81) or angiography-guided (angiography group, n = 118) drug-eluting stent implantation at the Affiliated Hospital of Inner Mongolia Medical University between September 2013 and September 2018. Major adverse cardiac events (MACE) were defined as cardiovascular death, sudden cardiac death, myocardial infarction. RESULTS: The IVUS group had considerably lower proportions of MACE within 1 year postoperatively (P = 0.002) and cardiac mortality within 3 years postoperatively (P = 0.018) compared to the angiography group. However, after adjusting for confounding variables, the hazard ratio for 3-year cardiac mortality was similar between the two groups (P = 0.28). In the IVUS group, there was considerably greater minimum lumen diameter (MLD) (P = 0.046), and reduced frequencies of target vessel restenosis (P < 0.050) and myocardial infarction (MI) (P = 0.024) compared to the angiography group. Cox regression analysis for 3-year cardiac mortality found that MSD was independently associated with low cardiac mortality (HR = 0.1, 95% CI: 0.01-14.92, P = 0.030). CONCLUSION: IVUS-guided drug-eluting stent implantation may lead to better long-term prognosis in patients with ULMCAD, and MSD may be a predictor for lower cardiac mortality.


Subject(s)
Coronary Angiography , Coronary Artery Disease , Drug-Eluting Stents , Ultrasonography, Interventional , Humans , Male , Female , Ultrasonography, Interventional/methods , Retrospective Studies , Coronary Artery Disease/surgery , Coronary Artery Disease/diagnostic imaging , Coronary Angiography/methods , Middle Aged , Aged , Percutaneous Coronary Intervention/methods , Treatment Outcome
12.
Korean Circ J ; 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38956941

ABSTRACT

The outstanding development in contemporary medicine, highlighted by percutaneous coronary intervention (PCI), was achieved through the adoption of drug-eluting stents (DESs). Although DES is the established therapy for patients undergoing PCI for de novo coronary artery disease (CAD), their drawbacks include restenosis, stent thrombosis, and the requirement for dual antiplatelet therapy (DAPT) with an uncertain duration regarding its optimality. Drug-coated balloon (DCB) treatment leaves nothing behind on the vessel wall, providing the benefit of avoiding stent thrombosis and not necessitating obligatory extended DAPT. After optimizing coronary blood flow, DCB treatment delivers an anti-proliferative drug directly coated on a balloon. Although more evidence is needed for the application of DCB treatment in de novo coronary lesions, recent studies suggest the safety and effectiveness of DCB treatment for diverse conditions including small and large vessel diseases, complex lesions like bifurcation lesions or diffuse or multivessel diseases, chronic total occlusion lesions, acute myocardial infarctions, patients at high risk of bleeding, and beyond. Consequently, we will review the current therapeutic choices for managing de novo CAD using DCB and assess the evidence supporting their concurrent application. Additionally, it aims to discuss future important perspectives.

13.
Clin Res Cardiol ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38958753

ABSTRACT

INTRODUCTION: Drug-coated balloon (DCB) is an established treatment option for in-stent restenosis and small vessel, de novo, coronary artery disease (CAD). Although the use of this tool is increasing in everyday practice, data regarding performance in the treatment of de novo, large vessel CAD (LV-CAD) is still lacking. A systematic review and meta-analysis were conducted to evaluate the efficacy and safety of DCB versus drug-eluting stent (DES) in this setting. METHODS: A comprehensive literature search was performed including Medline, Embase, and Cochrane electronic databases up to January 24, 2024, for studies which compared the efficacy and safety of DCB versus DES in the treatment of de novo lesions in large vessels (≥ 2.5 mm), reporting at least one clinical outcome of interest (PROSPERO ID: CRD42023470417). The analyzed outcomes were cardiovascular death (CVD), myocardial infarction (MI), target lesion revascularization (TLR), all-cause death (ACD), and late lumen loss (LLL) at follow-up. The effect size was estimated using a random effects model as risk ratio (RR) and mean difference (MD) and relative 95% confidence interval (CI). RESULTS: A total of 13 studies (6 randomized controlled trials and 7 observational studies) involving 2888 patients (DCB n = 1334; DES n = 1533) with de novo LV-CAD were included in this meta-analysis following our inclusion criteria. No differences were observed between DCB and DES in terms of CVD (RR 0.49; 95% CI [0.23-1.03]; p = 0.06), MI (RR 0.48; 95% CI [0.16-1.45]; p = 0.89), TLR (RR 0.73; 95% CI [0.40-1.34]; p = 0.32), ACD (RR 0.78; 95% CI [0.57-1.07]; p = 0.12), and LLL (MD - 0.14; 95% CI [- 0.30 to 0.02]; p = 0.10) at follow-up. DES proved a higher mean acute gain versus DCB [1.94 (1.73, 2.14) vs 1.31 (1.02, 1.60); p = 0.0006]. CONCLUSION: Our meta-analysis showed that DCB PCI might provide a promising option for the management of selected, de novo LV-CAD compared to DES. However, more focused RCTs are needed to further prove the benefits of a "metal-free" strategy in this subset of CAD.

15.
Circ J ; 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-38987207

ABSTRACT

BACKGROUND: Coronary angioscopy (CAS) has 2 unique abilities: direct visualization of thrombi and plaque color. However, in the recent drug-eluting stent (DES) era, serial CAS findings after DES implantation have not been fully elucidated. We investigated the impact of CAS findings after implantation of a polymer-free biolimus A9-coated stent (PF-BCS) or durable polymer everolimus-eluting stent (DP-EES).Methods and Results: We investigated serial CAS and optical coherence tomography (OCT) findings at 1 and 12 months in 99 patients who underwent PF-BCS or DP-EES implantation. We evaluated factors correlated with angioscopic thrombi and yellow plaque, and the clinical impact of both thrombi and yellow plaque at 12 months (BTY). The BTY group included 17 (22%) patients. The incidence and grade of thrombi and yellow plaque decreased from 1 to 12 months. Although no patients had newly appearing thrombi at 12 months, 2 DP-EES patients had newly appearing yellow plaque at 12 months. Multivariable analysis revealed HbA1c, minimum stent area, and adequate strut coverage were significant factors correlated with 12-month angioscopic thrombi, and DP-EESs were significantly correlated with 12-month yellow plaque. However, BTY was not correlated with clinical events. CONCLUSIONS: The management of diabetes, stent area, and adequate stent coverage are important for intrastent thrombogenicity and polymer-free stents are useful for stabilizing plaque vulnerability.

16.
Cardiol Res ; 15(3): 169-178, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38994223

ABSTRACT

Background: The use of multiple overlapping stents for long lesions in tapered coronary arteries has been associated with poor outcomes. This study was conducted to evaluate the 3-year safety and performance of the BioMime™ Morph sirolimus-eluting stent (SES) in very long (length 30 to ≤ 56 mm) coronary lesions in native coronary arteries with a reference vessel diameter of 2.25 to 3.50 mm. Methods: This was a prospective, single-center, observational, real-world, post-marketing surveillance study. Eligible patients were implanted with BioMime™ Morph SES. Patients were followed up at 6, 12, 24, and 36 months. Results: A total of 88 patients were enrolled in the study. The mean age was 58.72 ± 10.10 years and 82.95% were male. Most patients had angina (81.82%) and ischemic heart disease (78.41%), and there was a high prevalence of comorbidities like diabetes mellitus (59.09%), and hypertension (54.55%). A total of 92 long coronary de novo lesions were treated with BioMime™ Morph SES with an average stent length of 45.54 ± 10.20 mm. Device and procedural success rates were 100%. One patient died at 30 days and one case of myocardial infarction was recorded. The cumulative rates of major adverse cardiovascular events (MACEs) at 6, 12, 24, and 36 months were 3.41%, 6.82%, 7.95%, and 7.95%, respectively. There were no cases of stent thrombosis (ST), ischemia-driven target vessel revascularization, or ischemia-driven target lesion revascularization until 36 months of follow-up. Conclusion: BioMime™ Morph SES showed favorable outcomes up to 3 years in treating very long coronary lesions in native coronary arteries, as demonstrated by an acceptable rate of MACEs and absence of ST, based on clinical outcomes up to 3 years.

17.
Cardiol Res ; 15(3): 189-197, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38994230

ABSTRACT

Background: This study aimed to explore the factors influencing the drug-eluting stent (DES) selection criteria of cardiologists in association with percutaneous coronary intervention (PCI) volumes and to determine whether they value further DES improvements and modifications. Methods: The survey was conducted on a group of cardiologist operators from April 10 to 30, 2023. Results: The analysis included 126 operators who answered the questions. Of these, low-, intermediate-, and high-volume operators accounted for 49 (38.9%), 47 (37.3%), and 30 (23.8%), respectively. Overall, Xience™ everolimus-eluting stent (CoCr-EES) was most frequently used, with > 70% of cardiologists using it in > 20% of their PCI practice. The percentage of selection by low-, intermediate-, and high-volume operators among the DESs used demonstrated no difference, except for dual-therapy sirolimus-eluting and CD34+ antibody-coated Combo® stent (DTS). Logistic regression analysis revealed that low-volume operators are less likely to be affected in terms of company/sales representative (odds ratio (OR): 0.402, P = 0.031) and bending lesions (OR: 0.339, P = 0.037) for selecting DES. Low-volume operators less frequently selected Resolute Onyx™ zotarolimus-eluting stents (OR: 0.689, P = 0.043) and DTS (Drug-Eluting Stents) (OR: 0.361, P = 0.006) for PCI. Conclusions: The current study results indicate that patient background, DES performance, and product specifications were not criteria for DES selection in cardiologists with different PCI volumes in routine PCI.

18.
Materials (Basel) ; 17(13)2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38998396

ABSTRACT

The CoCrFeMnNi high-entropy alloy is commonly used for vascular stents due to its excellent mechanical support and ductility. However, as high-entropy alloy stents can cause inflammation in the blood vessels, leading to their re-narrowing, drug-eluting stents have been developed. These stents have nanopores on their surfaces that can carry drug particles to inhibit inflammation and effectively prevent re-narrowing of the blood vessels. To optimize the mechanical properties and drug-carrying capacity of high-entropy alloy stents, a high-entropy alloy system with different wide and deep square-shaped nanopore distributions is created using molecular dynamics. The mechanical characteristics and dislocation evolution mechanism of different nanopore high-entropy alloy systems under tensile stress were studied. The results showed that the CoCrFeMnNi high-entropy alloy with a rational nanopore distribution can effectively maintain the mechanical support required for a vascular stent. This research provides a new direction for the manufacturing process of nanopores on the surfaces of high-entropy alloy stents.

19.
Egypt Heart J ; 76(1): 91, 2024 Jul 10.
Article in English | MEDLINE | ID: mdl-38985375

ABSTRACT

BACKGROUND: One million individuals in the USA die from acute myocardial infarction (MI), which currently affects 3 million people globally. The available data about the early and late outcomes of both biodegradable polymer drug-eluting stents (BP-DES) and durable polymer drug-eluting stents exhibit inconsistency. We performed a meta-analysis comparing the safety and efficacy of BP-DES with DP-DES. METHODS: PubMed, Google Scholar, EMBASE, Cochrane, Ovid Medline, and Clinical Trials.gov databases were used to find out studies comparing BP-DES to DP-DES. All the analyses used the random-effects model. RESULTS: A total of 18 studies were incorporated in this meta-analysis that involved 28,874 patients, out of which 11,997 received the BP Stent, and the rest of 16,578 received the DP stent. Thorough analyses revealed that the risk of all-cause death was significantly higher in the BP-DES group (5.4% vs 2.7%) (RR 1.22, p 0.02) for two years or less than two-year follow-up. For studies with more than two years of follow-up, all-cause death was 9.07% (599/6603) in BP-DES and 9.47% (531/5602) in the DP-DES group but failed to achieve statistically significant levels (RR 0.97, p 0.58). CONCLUSIONS: The study revealed no clinically significant (P value was > 0.05) differences in all-cause death, cardiac death, target lesion revascularization (TLR), late stent thrombosis, device-oriented composite endpoint/target lesion failure (DOCE/TLF), myocardial infarction (MI), target vessel MI, target vessel revascularization (TVR), target vessel infarction (TVI) between BP-DES and DP-DES for more than two years of follow-up. Additionally, all-cause death was only outcomes which found to have a statistically significant difference for less than two years of follow-up, while remaining were statistically non-significant.

20.
Catheter Cardiovasc Interv ; 104(2): 181-190, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38988147

ABSTRACT

BACKGROUND: In the elderly people with unprotected left main distal bifurcation lesions (ULMD), percutaneous coronary intervention (PCI) is often selected as first choice treatment strategy because of perioperative high risk of coronary artery bypass graft surgery due to their large number of comorbidities. Also, some recent papers reported that geriatric nutritional risk index (GNRI) is also strongly associated with clinical outcomes after interventional procedures in elderly patients. OBJECTIVES: We assessed clinical outcomes after PCI for ULMD and the impact of GNRI in elderly patients. METHODS: We identified 669 non dialysis patients treated with current generation drug-eluting stent for ULMD from MITO registry. We divided the patients to the following 2 groups; elderly group (n = 240, age ≥75) and young group (n = 429, age <75). Additionally, we could calculate GNRI and divided elderly group into 2 group based on the median value of the GNRI. The primary endpoint was all-cause mortality. RESULTS: All-cause mortality was significantly higher in elderly group [adjusted hazard ratio (HR) 2.37; 95% confidence interval (CI), 1.40-4.02; p = 0.001]. All-cause mortality was significantly higher in low GNRI elderly group compared to other 2 groups (Adjusted HR of elderly with low GNRI: 3.56, 95%CI (1.77-7.14), p < 0.001). Cardiovascular mortality was comparable between two groups. TLR rate was significantly lower in elderly group (adjusted HR 0.57; 95% CI, 0.34-0.97; p = 0.035). CONCLUSIONS: The elderly had higher all-cause mortality after PCI for ULMD compared to young people. Especially, the elderly with low GNRI were extremely associated with poorer outcomes.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Geriatric Assessment , Percutaneous Coronary Intervention , Registries , Humans , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Percutaneous Coronary Intervention/instrumentation , Aged , Male , Female , Coronary Artery Disease/mortality , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Risk Factors , Treatment Outcome , Risk Assessment , Age Factors , Time Factors , Aged, 80 and over , Middle Aged , Nutritional Status , Retrospective Studies , Japan
SELECTION OF CITATIONS
SEARCH DETAIL