1.
Pain Pract ; 23(8): 886-891, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37381678

ABSTRACT

BACKGROUND: Spinal cord stimulation (SCS) is a minimally invasive therapy that is increasingly used to treat refractory neuropathic pain. Although this technique has a low incidence of serious long-term adverse sequelae, the risk of complications such as inadvertent dural puncture remains. OBJECTIVES: The goal of this article was to determine the impact of the contralateral oblique (CLO) fluoroscopic view incidence of postdural puncture headache (PDPH) during spinal cord stimulator implantation as compared to lateral fluoroscopic view. METHODS: This was a single academic institution retrospective analysis of electronic medical records spanning an approximate 20-year time period. Operative and postoperative notes were reviewed for details on dural puncture, including technique and spinal level of access, the development of a PDPH, and subsequent management. RESULTS: Over nearly two decades, a total of 1637 leads inserted resulted in 5 PDPH that were refractory to conservative measures but responded to epidural blood patch without long-term complications. The incidence of PDPH per lead insertion utilizing loss of resistance and lateral fluoroscopic guidance was 0.8% (4/489). However, adoption of CLO guidance was associated with a lower rate of PDPH at 0.08% (1/1148), p < 0.02. CONCLUSIONS: The incorporation of the CLO view to guide epidural needle placement can decrease the odds of a PDPH during percutaneous SCS procedures. This study further provides real-world data supporting the potential enhanced accuracy of epidural needle placement in order to avoid unintentional puncture or trauma to deeper spinal anatomic structures.


Subject(s)
Anesthesia, Epidural , Post-Dural Puncture Headache , Spinal Cord Stimulation , Humans , Post-Dural Puncture Headache/epidemiology , Post-Dural Puncture Headache/etiology , Post-Dural Puncture Headache/therapy , Retrospective Studies , Spinal Cord Stimulation/adverse effects , Incidence , Anesthesia, Epidural/adverse effects , Blood Patch, Epidural/methods
2.
Arch Orthop Trauma Surg ; 143(9): 5713-5717, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37284880

ABSTRACT

Posterior column fractures are common acetabular injuries. Although displaced fractures require open reduction and fixation, undisplaced patterns may benefit from percutaneous screw fixation. The combination of iliac oblique with inlet and outlet views offers an intuitive and panoramic rendering of the bony corridor into the posterior column; lateral cross table view completes the sequence of fluoroscopic projections. Herein we describe the use of outlet/inlet iliac views and a detailed procedure for percutaneous retrograde posterior column screw fixation.


Subject(s)
Fracture Fixation, Internal , Fractures, Bone , Humans , Fracture Fixation, Internal/methods , Bays , Bone Screws , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Ilium/surgery , Acetabulum/surgery
3.
Article in English | MEDLINE | ID: mdl-36542648

ABSTRACT

BACKGROUND: Use of a right-left (R-L) cusp overlap view for transcatheter aortic valve replacement (TAVR) with self-expanding valves has recently been proposed aiming to reduce permanent pacemaker implantation (PPMI). An objective, data-driven explanation for this observation is missing. AIMS: To assess the impact of different implantation techniques on the risk of PPMI following TAVR with the Portico/NavitorTM transcatheter heart valve (THV; Abbott). METHODS: A TAVR-population treated with Portico/NavitorTM had the THV implanted in a right versus left anterior oblique (RAO/LAO) fluoroscopic view with no parallax in the delivery system. The impact of these different implantation views on the spatial relationship between THV and native aortic annulus and the risk of conduction disturbances and PPMI after TAVR was studied. RESULTS: A total of 366 matched TAVR patients were studied: 183 in the RAO group and 183 in the LAO group. The degree of aortic annulus plane tilt was significantly smaller in the RAO versus LAO group (median: 0° vs. 23°, p < 0.001), with no plane tilt in 105 out of 183 cases (57.3%) in the RAO group. At 30 days after TAVR, the overall PPMI and guideline-directed PPMI rates were 12.6% versus 18.0% (p = 0.15) and 8.2% versus 15.3% (p = 0.04) in the RAO versus LAO group, respectively. CONCLUSIONS: Use of a R-L cusp overlap (RAO-caudal) view for implantation of the Portico/NavitorTM valve results in less tilt of the native aortic annulus plane and a clear trend toward a lower 30-day PPMI rate as compared to TAVR using the conventional LAO implantation view.

4.
J Cardiovasc Electrophysiol ; 33(6): 1255-1261, 2022 06.
Article in English | MEDLINE | ID: mdl-35304791

ABSTRACT

INTRODUCTION: Few predictors of low capture threshold before the deployment of the Micra transcatheter pacing system (Micra TPS) have been determined. We aimed to identify fluoroscopic predictors of an acceptable capture threshold before Micra TPS deployment. METHODS: Sixty patients were successfully implanted with Micra TPS. Before deployment, gooseneck appearance of the catheter shaft was quantified using the angle between the tangent line of the shaft and the cup during diastole in the right anterior oblique (RAO) view. The direction of the device cup toward the ventricular septum was evaluated using the angle between the cup and the horizontal plane in the left anterior oblique (LAO) view. RESULTS: Of the 95 deployments we evaluated, 56 achieved an acceptable capture threshold of ≤2.0 V at 0.24 ms. In this acceptable threshold group, the deflection angle of the gooseneck shaft was significantly larger and the device cup was placed more horizontally with a lower elevation angle compared with those in the high threshold group. A deflection angle of ≥6° and an elevation angle of ≤30° were identified as the predictors of an acceptable capture threshold after deployment. An acceptable capture threshold was achieved in 24/31 (77.4%) patients in whom either angle criterion was satisfied at the first deployment. CONCLUSIONS: Diastolic gooseneck appearance of the delivery catheter in the RAO view or near-horizontal direction in the LAO view predicts an acceptable capture threshold after deployment. The shape of the delivery catheter before deployment should be evaluated using multiple fluoroscopic views to ensure successful implantation of Micra TPS.


Subject(s)
Pacemaker, Artificial , Equipment Design , Fluoroscopy , Humans , Treatment Outcome