Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 434
Filter
1.
Article in English | MEDLINE | ID: mdl-39287937

ABSTRACT

In this paper, we give an overview of novel main-chain azobenzene-based fluorinated poly(arylene ether)s with different content of azo groups, aiming at providing a better understanding of the link between a number of N═N bonds and the macroscopic response of the material. We discuss chemical synthesis and molecular structure and report on a comprehensive analysis of the polymer properties, thermal behavior, and mechanical strength. We show that a higher content of azobenzene moieties reduces the mechanical strength of the polymer materials. On the other hand, polymers with a higher content of azobenzene demonstrate higher values of induced birefringence due to a larger number of azobenzene in the trans form. The photoisomerization constants of all polymers fall within a very close range. The minor variations are attributed to the number of azobenzene groups in the polymer composition and the conformational arrangements of the polymer chain packing. The developed light-sensitive polymers were employed for dynamic control and manipulation of the liquid crystal orientation by polarization of the incident light. After the double irradiation of the substrates using appropriate photomasks, we made patterned cells that consist of domains with different high-resolution liquid crystal director orientations.

2.
Int J Mol Sci ; 25(16)2024 Aug 07.
Article in English | MEDLINE | ID: mdl-39201289

ABSTRACT

Sensitive, accurate, and early detection of biomarkers is essential for prompt response to medical decisions for saving lives. Some infectious diseases are deadly even in small quantities and require early detection for patients and public health. The scarcity of these biomarkers necessitates signal amplification before diagnosis. Recently, we demonstrated single-molecule-level detection of tuberculosis biomarker, lipoarabinomannan, from patient urine using silver plasmonic gratings with thin plasma-activated alumina. While powerful, biomarker binding density was limited by the surface density of plasma-activated carbonyl groups, that degraded quickly, resulting in immediate use requirement after plasma activation. Therefore, development of stable high density binding surfaces such as high binding polystyrene is essential to improving shelf-life, reducing binding protocol complexity, and expanding to a wider range of applications. However, any layers topping the plasmonic grating must be ultra-thin (<10 nm) for the plasmonic enhancement of adjacent signals. Furthermore, fabricating thin polystyrene layers over alumina is nontrivial because of poor adhesion between polystyrene and alumina. Herein, we present the development of a stable, ultra-thin polystyrene layer on the gratings, which demonstrated 63.8 times brighter fluorescence compared to commercial polystyrene wellplates. Spike protein was examined for COVID-19 demonstrating the single-molecule counting capability of the hybrid polystyrene-plasmonic gratings.


Subject(s)
Biosensing Techniques , Polystyrenes , Polystyrenes/chemistry , Humans , Biosensing Techniques/methods , COVID-19/diagnosis , COVID-19/virology , SARS-CoV-2/isolation & purification , SARS-CoV-2/metabolism , Aluminum Oxide/chemistry , Spike Glycoprotein, Coronavirus/metabolism , Lipopolysaccharides , Biomarkers
3.
J Synchrotron Radiat ; 31(Pt 5): 1043-1049, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39088402

ABSTRACT

Multilayer gratings are increasingly popular optical elements at X-ray beamlines, as they can provide much higher photon flux in the tender X-ray range compared with traditional single-layer coated gratings. While there are several proprietary software tools that provide the functionality to simulate the efficiencies of such gratings, until now the X-ray community has lacked an open-source alternative. Here MLgrating is presented, a program for simulating the efficiencies of both multilayer gratings and single-layer coated gratings for X-ray applications. MLgrating is benchmarked by comparing its output with that of other software tools and plans are discussed for how the program could be extended in the future.

4.
Sensors (Basel) ; 24(16)2024 Aug 16.
Article in English | MEDLINE | ID: mdl-39204997

ABSTRACT

Array waveguide gratings (AWGs) have been widely used in multi-purpose and multi-functional integrated photonic devices for Microwave photonics (MWP) systems. In this paper, we compare the effect of output waveguide configurations on the performance of AWGs. The AWG with an output waveguide converging on the grating circle had larger crosstalk and lower nonuniformity. We also fabricated a 1 × 8 AWG with an output waveguide converging onto the SOI's grating circle, whose central operation wavelength was around 1550 nm. The fabricated AWG has a chip size of 500 µm × 450 µm. Experimental results show that the adjacent channel crosstalk is -12.68 dB. The center channel insertion loss, as well as 3 dB bandwidth, are 4.18 dB and 1.22 nm at 1550 nm, respectively. The nonuniformity is about 0.494 dB, and the free spectral range is 19.4 nm. The proposed AWG is expected to play an important role in future MWP systems given its good nonuniformity and insertion loss level.

5.
Nano Lett ; 24(33): 10055-10061, 2024 Aug 21.
Article in English | MEDLINE | ID: mdl-39047260

ABSTRACT

Nonlocal metasurfaces, exemplified by resonant waveguide gratings (RWGs), spatially and angularly configure optical wavefronts through narrow-band resonant modes, unlike the broad-band and broad-angle responses of local metasurfaces. However, forward design techniques for RWGs remain constrained at lower efficiency. Here, we present a topology-optimized metasurface resonant waveguide grating (MRWG) composed of titanium dioxide on a glass substrate capable of operating simultaneously at red, yellow, green, and blue wavelengths. Through adjoint-based topology optimization, while considering nonlocal effects, we significantly enhance its diffraction efficiency, achieving numerical efficiencies up to 78% and Q-factors as high as 1362. Experimentally, we demonstrated efficiencies of up to 59% with a Q-factor of 93. Additionally, we applied our topology-optimized metasurface to color selectivity, producing vivid colors at 4 narrow-band wavelengths. Our investigation represents a significant advancement in metasurface technology, with potential applications in see-through optical combiners and augmented reality platforms.

6.
Sensors (Basel) ; 24(14)2024 Jul 13.
Article in English | MEDLINE | ID: mdl-39065935

ABSTRACT

Silver-based grating structures offer means for implementing low-cost, efficient grating couplers for use in surface plasmon resonance (SPR) sensors. One-dimensional grating structures with a fixed periodicity are confined to operate effectively within a single planar orientation. However, two-dimensional grating structures as well as grating structures with variable periodicity allow for the plasmon excitation angle to be seamlessly adjusted. This study demonstrates silver-based grating designs that allow for the plasmon excitation angle to be adjusted via rotation or beam position. The flexible angle adjustment opens up the possibility of developing SPR sensor designs with an expanded dynamic range and increased flexibility in sensing applications. The results demonstrate that efficient coupling into two diffraction orders is possible, which ultimately leads to an excitation angle range from 16° to 40° by rotating a single structure. The findings suggest a promising direction for the development of versatile and adaptable SPR sensing platforms with enhanced performance characteristics.

7.
Sensors (Basel) ; 24(14)2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39065998

ABSTRACT

In the context of hydroelectric plants, this article emphasizes the imperative of robust monitoring strategies. The utilization of fiber-optic sensors (FOSs) emerges as a promising approach due to their efficient optical transmission, minimal signal attenuation, and resistance to electromagnetic interference. These optical sensors have demonstrated success in diverse structures, including bridges and nuclear plants, especially in challenging environments. This article culminates with the depiction of the development of an array of sensors featuring Fiber Bragg Gratings (FBGs). This array is designed to measure deformation and temperature in protective grids surrounding the turbines at the Santo Antônio Hydroelectric Plant. Implemented in a real-world scenario, the device identifies deformation peaks, indicative of water flow obstructions, thereby contributing significantly to the safety and operational efficiency of the plant.

8.
Nanomaterials (Basel) ; 14(14)2024 Jul 20.
Article in English | MEDLINE | ID: mdl-39057904

ABSTRACT

Fiber Bragg gratings are key components for optical fiber sensing applications in harsh environments. This paper investigates the structural and chemical characteristics of femtosecond laser photo-inscribed microvoids. These voids are at the base of type III fs-gratings consisting of a periodic array of microvoids inscribed at the core of an optical fiber. Using high-resolution techniques such as quantitative phase microscopy, electron transmission microscopy, and scattering-type scanning near-field IR optical microscopy, we examined the structure of the microvoids and the densified shells around them. We also investigated the high-temperature behavior of the voids, revealing their evolution in size and shape under step isochronal annealing conditions up to 1250 °C.

9.
Micromachines (Basel) ; 15(7)2024 Jun 30.
Article in English | MEDLINE | ID: mdl-39064374

ABSTRACT

Large-scale diffraction gratings were fabricated in surface relief on azobenzene thin films and transferred to flexible PDMS substrates using soft lift-off lithography. The PDMS gratings were strained along the grating vector axis and the resulting surface topography was analyzed using diffraction angle measurements, AFM imagery and surface plasmon resonance (SPR) spectra. All measurement methods exhibited a linear response in strain indicating the useability of these sensors in real-world applications. For SPR-based strain sensing, an increasing pitch and a decreasing modulation depth were observed with increasing strain. The SPR peak shifted by ~1.0 nm wavelength and the SPR intensity decreased by ~0.3 a.u. per percentage of applied strain. The tested PDMS samples retained their integrity even after multiple cycles of stretching and relaxation, making them a suitable strain sensor.

10.
Sensors (Basel) ; 24(11)2024 May 23.
Article in English | MEDLINE | ID: mdl-38894131

ABSTRACT

In the paper, a new method of phase measurement error suppression in a phase-sensitive optical time domain reflectometer is proposed and experimentally proved. The main causes of phase measurement errors are identified and considered, such as the influence of the recording interferometer instabilities and laser wavelength instability, which can cause inaccuracies in phase unwrapping. The use of a Mach-Zender interferometer made by 3 × 3 fiber couplers is proposed and tested to provide insensitivity to the recording interferometer and laser source instabilities. It is shown that using all three available photodetectors of the interferometer, instead of just one pair, achieves significantly better accuracy in the phase unwrapping. A novel compensation scheme for accurate phase measurements in a phase-sensitive optical time domain reflectometer is proposed, and a comparison of the measurement signals with or without such compensation is shown and discussed. The proposed method, using three photodetectors, allows for very good compensation of the phase measurement errors arising from common-mode noise from the interferometer and laser source, providing a significant improvement in signal detection. In addition, the method allows the tracking of slow temperature changes in the monitored fiber/object, which is not obtainable when using a simple low-pass filter for phase unwrapping error reduction, as is customary in several systems of this kind.

11.
Discov Nano ; 19(1): 104, 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38886274

ABSTRACT

Advancements in nanofabrication technology have greatly facilitated research on nanostructures and their associated properties. Among these structures, subwavelength components have emerged as promising candidates for ultra-compact optical elements, can potentially supplant conventional optical components and enable the realization of compact and efficient optical devices. Spectral analysis within the infrared spectrum offers a wealth of information for monitoring crop health, industrial processes, and target identification. However, conventional spectrometers are typically bulky and expensive, driving an increasing demand for cost-effective spectral sensors. Here we investigate three distinct subwavelength grating structures designed to function as narrowband filters within the short-wavelength infrared (SWIR) range. Through simple adjustments to the period of grating strips, these filters selectively transmit light across a wide wavelength range from 1100 to 1700 nm with transmission exceeding 70% and full width at half maximum (FWHM) down to 6 nm. Based on a simple design, the results present great potential of subwavelength grating filters for multiband integration and developing ultra-compact spectral sensors.

12.
Sensors (Basel) ; 24(12)2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38931780

ABSTRACT

Conventional optical fiber temperature/strain sensors often have to make compromises between the resolution and the dynamic range. Here we present a new method that meets the measurement requirements for both high resolution and large dynamic range. A high-quality optical fiber Fabry-Perot Interferometer (FPI) constructed using a pair of chirped fiber Bragg gratings is employed as the sensor and a dual-mode direct spectrum interrogation method is proposed to identify the small drift of external temperature or strain. As a proof-of-concept illustration, a temperature resolution of 0.2 °C within 30-130 °C is demonstrated. For strain sensing, the resolution can be 10 µÎµ within 0-1000 µÎµ. The measurement resolution can be improved further by routinely increasing the reflectivity of the CFBG and the cavity length and the sensor can also be mass-produced. This new sensing schema not only resolves the conflict between the resolution and the dynamic range of fiber-optic temperature/strain sensors but can also be extended to other sensors and measurands.

13.
ACS Sens ; 9(6): 3027-3036, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38864606

ABSTRACT

Surface plasmon (SP) excitation in metal-coated tilted fiber Bragg gratings (TFBGs) has been a focal point for highly sensitive surface biosensing. Previous efforts focused on uniform metal layer deposition around the TFBG cross section and temperature self-compensation with the Bragg mode, requiring both careful control of the core-guided light polarization and interrogation over most of the C + L bands. To circumvent these two important practical limitations, we studied and developed an original platform based on partially coated TFBGs. The partial metal layer enables the generation of dual-comb resonances, encompassing highly sensitive (TM/EH mode families) and highly insensitive (TE/HE mode families) components in unpolarized transmission spectra. The interleaved comb of insensitive modes acts as wavelength and power references within the same spectral region as the SP-active modes. Despite reduced fabrication and measurement complexity, refractometric accuracy is not compromised through statistical averaging over seven individual resonances within a narrowband window of 10 nm. Consequently, measuring spectra over 60 nm is no longer needed to compensate for small temperature or power fluctuations. This sensing platform brings the following important practical assets: (1) a simpler fabrication process, (2) no need for polarization control, (3) limited bandwidth interrogation, and (4) maintained refractometric accuracy, which makes it a true game changer in the ever-growing plasmonic sensing domain.


Subject(s)
Optical Fibers , Surface Plasmon Resonance , Surface Plasmon Resonance/instrumentation , Surface Plasmon Resonance/methods , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Fiber Optic Technology/instrumentation
14.
J Colloid Interface Sci ; 669: 458-465, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38723534

ABSTRACT

This article investigates the performance of a contact-mode Triboelectric Nanogenerator (TENG) utilizing polydimethylsiloxane (PDMS) with nano gratings as a dielectric in a metal-dielectric configuration. The evaluation encompasses the impact of gratings, tapping frequency, various load conditions, and contact area on the TENG performance. The fabrication involves spin-coating PDMS onto a master mold to create the device. Experimental measurements reveal a significant enhancement of 97% in open-circuit voltage by introducing gratings on PDMS. Furthermore, as the tapping frequency increases from 1 Hz to 3 Hz, there is a corresponding rise of 108% in output voltage. The influence of load resistance on TENG output performance demonstrates its ability to drive different loads efficiently. Moreover, enlarging the contact area of the device substantially increases the open-circuit voltage. A device with a 400 mm2 contact area can generate a voltage of 80 V at a low frequency of 3 Hz, indicating the importance of considering device size and contact area for specific applications. A practical circuit integrating a TENG with a full-wave bridge rectifier demonstrates energy harvesting capabilities by successfully illuminating a light-emitting diode (LED) and charging various capacitors. The fabricated devices exhibit better performance along with a cost-effective and easy fabrication process.

15.
Ultrasonics ; 141: 107338, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38723293

ABSTRACT

Recently, the moiré pattern has attracted lots of attention by superimposing two planar structures of regular geometries, such as two sets of metasurfaces or gratings. Here, we show the experimental investigation of acoustic moiré effect by using twisted bilayer gratings (i.e., one grating twisted with respect to the other). We observed the guided resonance that occurred when the incident ultrasound beam was coupled with the guiding modes in a meta-grating, significantly influencing the reflection and transmission. Tunable guided resonances from the moiré effect with complete ultrasound reflection at different frequencies were further demonstrated in experiments. Combining the measurements of transmission spectra and the Fast Fourier Transform analyses, we reveal the guided resonance frequencies of moiré ultrasonic metasurface can be effectively controlled by adjusting the twisting angle of the bilayer gratings. Our results can be explained in a simplified model based on the band folding theory, providing a reliable prediction on the precise control of ultrasound reflection via the twisting angle adjustment. Our work extends the moiré metasurface from optics into acoustics, which shows more possibilities for the ultrasound beam engineering from the moiré effect and enables the exploration of functional acoustic devices for ultrasound imaging, treatment and diagnosis.

16.
Med Phys ; 51(5): 3648-3657, 2024 May.
Article in English | MEDLINE | ID: mdl-38558430

ABSTRACT

BACKGROUND: X-ray multi-contrast imaging with gratings provides a practical method to detect differential phase and dark-field contrast images in addition to the x-ray absorption image traditionally obtained in laboratory or hospital environments. Systems have been developed for preclinical applications in areas including breast imaging, lung imaging, rheumatoid arthritis hand imaging and kidney stone imaging. PURPOSE: Prevailing x-ray interferometers for multi-contrast imaging include Talbot-Lau interferometers and universal moiré effect-based phase-grating interferometers. Talbot-Lau interferometers suffer from conflict between high interferometer sensitivity and large field of view (FOV) of the object being imaged. A small period analyzer grating is necessary to simultaneously achieve high sensitivity and large FOV within a compact imaging system but is technically challenging to produce for high x-ray energies. Phase-grating interferometers suffer from an intrinsic fringe period ranging from a few micrometers to several hundred micrometers that can hardly be resolved by large area flat panel x-ray detectors. The purpose of this work is to introduce a four-grating x-ray interferometer that simultaneously allows high sensitivity and large FOV, without the need for a small period analyzer grating. METHODS: The four-grating interferometer consists of a source grating placed downstream of and close to the x-ray source, a pair of phase gratings separated by a fixed distance placed downstream of the source grating, and an analyzer grating placed upstream of and close to the x-ray detector. The object to be imaged is placed upstream of and close to the phase-grating pair. The distance between the source grating and the phase-grating pair is designed to be far larger than that between the phase-grating pair and the analyzer grating to promote simultaneously high sensitivity and large FOV. The method was evaluated by constructing a four-grating interferometer with an 8 µm period source grating, a pair of phase gratings of 2.4 µm period, and an 8 µm period analyzer grating. RESULTS: The fringe visibility of the four-grating interferometer was measured to be ≈24% at 40 kV and ≈18% at 50 kV x-ray tube operating voltage. A quartz bead of 6 mm diameter was imaged to compare the theoretical and experimental phase contrast signal with good agreement. Kidney stone specimens were imaged to demonstrate the potential of such a system for classification of kidney stones. CONCLUSIONS: The proposed four-grating interferometer geometry enables a compact x-ray multi-contrast imaging system with simultaneously high sensitivity and large FOV. Relaxation of the requirement for a small period analyzer grating makes it particularly suitable for high x-ray energy applications such as abdomen and chest imaging.


Subject(s)
Interferometry , Interferometry/instrumentation , X-Rays , Equipment Design
17.
Sensors (Basel) ; 24(7)2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38610496

ABSTRACT

Many techniques have been studied for recovering information from shared media such as optical fiber that carries different types of communication, sensing, and data streaming. This article focuses on a simple method for retrieving the targeted information with the least necessary number of significant samples when using statistical population sampling. Here, the focus is on the statistical denoising and detection of the fiber Bragg grating (FBG) power spectra. The impact of the two-sided and one-sided sliding window technique is investigated. The size of the window is varied up to one-half of the symmetrical FBG power spectra bandwidth. Both, two- and one-sided small population sampling techniques were experimentally investigated. We found that the shorter sliding window delivered less processing latency, which would benefit real-time applications. The calculated detection thresholds were used for in-depth analysis of the data we obtained. It was found that the normality three-sigma rule does not need to be followed when a small population sampling is used. Experimental demonstrations and analyses also showed that novel denoising and statistical threshold detection do not depend on prior knowledge of the probability distribution functions that describe the FBG power spectra peaks and background noise. We have demonstrated that the detection thresholds' adaptability strongly depends on the mean and standard deviation values of the small population sampling.

18.
eNeuro ; 11(4)2024 Apr.
Article in English | MEDLINE | ID: mdl-38604776

ABSTRACT

Sensory stimulation is often accompanied by fluctuations at high frequencies (>30 Hz) in brain signals. These could be "narrowband" oscillations in the gamma band (30-70 Hz) or nonoscillatory "broadband" high-gamma (70-150 Hz) activity. Narrowband gamma oscillations, which are induced by presenting some visual stimuli such as gratings and have been shown to weaken with healthy aging and the onset of Alzheimer's disease, hold promise as potential biomarkers. However, since delivering visual stimuli is cumbersome as it requires head stabilization for eye tracking, an equivalent auditory paradigm could be useful. Although simple auditory stimuli have been shown to produce high-gamma activity, whether specific auditory stimuli can also produce narrowband gamma oscillations is unknown. We tested whether auditory ripple stimuli, which are considered an analog to visual gratings, could elicit narrowband oscillations in auditory areas. We recorded 64-channel electroencephalogram from male and female (18 each) subjects while they either fixated on the monitor while passively viewing static visual gratings or listened to stationary and moving ripples, played using loudspeakers, with their eyes open or closed. We found that while visual gratings induced narrowband gamma oscillations with suppression in the alpha band (8-12 Hz), auditory ripples did not produce narrowband gamma but instead elicited very strong broadband high-gamma response and suppression in the beta band (14-26 Hz). Even though we used equivalent stimuli in both modalities, our findings indicate that the underlying neuronal circuitry may not share ubiquitous strategies for stimulus processing.


Subject(s)
Acoustic Stimulation , Auditory Perception , Electroencephalography , Gamma Rhythm , Humans , Male , Female , Gamma Rhythm/physiology , Adult , Auditory Perception/physiology , Young Adult , Photic Stimulation/methods , Visual Perception/physiology
19.
Nano Lett ; 24(15): 4521-4527, 2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38565218

ABSTRACT

Increasing near-field radiative heat transfer between two bodies separated by a vacuum gap is crucial for enhancing the power density in radiative energy transport and conversion devices. However, the largest radiative heat transfer coefficient between two realistic materials at room temperature is limited to around 2000 W/(m2·K) for a gap of 100 nm. Here, analogous to conventional plate-fin heat exchangers based on convection, we introduce the concept of a nanophotonic heat exchanger, which enhances near-field radiative heat transfer using two bodies with interpenetrating gratings. Our calculations, based on rigorous fluctuational electrodynamics, show that the radiative heat transfer coefficient between the bodies separated by a 100 nm gap can significantly exceed 2000 W/(m2·K) by increasing the aspect ratios of the gratings. We develop a semianalytical heat transfer model that agrees well with the rigorous calculations for design optimization. Our work opens new opportunities for enhancing near-field radiative heat transfer between any materials.

20.
Sci Rep ; 14(1): 9939, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38688955

ABSTRACT

Optical cross-correlation is a technique that can achieve both high specificity and high sensitivity when deployed as the basis for a sensing technology. Offering significant gains in cost, size and complexity, it can also deliver significantly higher signal-to-noise ratios than traditional approaches such as absorption methodologies. In this paper, we present an optical cross-correlation technology constructed around a bespoke customised Fiber Bragg Grating (FBG). Exploiting the remarkable flexibility in design enabled by multiple aperiodic Bragg gratings, optical filters are devised that exactly mimic the absorption features of a target gas species (for this paper, acetylene C 2 H 2 ) over some waveband of interest. This grating forms the heart of the sensor architecture described here that employs modulated optical cross-correlation for gas detection. An experimental demonstration of this approach is presented, and shown to be capable of differentiating between different concentrations of the C 2 H 2 target gas. Furthermore these measurements are shown to be robust against interloper species, with minimal impact on the detection signal-to-noise arising from the introduction of contaminant gases. This represents is a significant step toward the use of customised FBGs as low-cost, compact, and highly customisable photonic devices for deployment in gas detection.

SELECTION OF CITATIONS
SEARCH DETAIL