Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.874
Filter
1.
J Vasc Access ; : 11297298241262344, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39091077

ABSTRACT

Central venous catheters are a frequently used vascular access for hemodialysis. Fibrin sheath formation is a common complication and is associated with catheter malfunction. Although fibrin sheath angioplasty with catheter exchange is a frequently employed procedure, it can be associated with mechanical complications. An important technical step in this procedure is progression of the guide-wire into the inferior vena cava. Focal alveolar hemorrhage is a very rare complication of this procedure. We report a case of a 70-year old patient on dual antiplatelet therapy who underwent fibrin sheath angioplasty with guide-wire catheter exchange and experienced focal alveolar hemorrhage presenting as hemoptysis and acute type 1 respiratory failure. Progression of the guide-wire into the pulmonary circulation and antithrombotic therapy played a significant role in the development of this complication. This report aims to call attention to a poorly described and potentially serious yet avoidable complication of fibrin sheath angioplasty with guide-wire catheter exchange.

2.
Front Endocrinol (Lausanne) ; 15: 1402605, 2024.
Article in English | MEDLINE | ID: mdl-39114289

ABSTRACT

Introduction: Thyroid nodules are extremely common being detected by ultrasonography in up to 67% of the population, with current surgical tenet maintaining that lobectomy is required for large symptomatic benign nodules or autonomously functionally nodules resulting in a risk of hypothyroidism or recurrent laryngeal nerve injury even in high volume centres. The introduction of radiofrequency ablation (RFA) has allowed thermal ablation of both benign and autonomously functioning thyroid nodules with minimal morbidity. The moving shot technique is the most well-established technique in performing RFA of thyroid nodules, and has proven to be safe, efficacious, accurate and successful amongst experienced clinicians. The purpose of this article to propose the use of a novel guide when performing RFA of thyroid nodules in clinical practice utilizing the moving shot technique. Methods: The technique proposed of RFA involves the use of a 10MHz linear ultrasound probe attached to an 18G guide which provides robust in line visualisation of a 7cm or 10cm radiofrequency probe tip (STARmed, Seoul, Korea) utilizing the trans isthmic moving shot technique. A geometric analysis of the guide has been illustrated diagrammatically. Results: The use of an 18G radiofrequency probe guide (CIVCO Infiniti Plus™ Needle Guide) maintains in line visualisation of the radiofrequency probe over a cross-sectional area up to 28cm2, facilitating efficient and complete ablation of conceptual subunits during RFA of thyroid nodules. Discussion: Radiofrequency ablation of thyroid nodules can be performed safely and effectively using the novel radiofrequency probe guide proposed which we believe potentially improves both accuracy and overall efficiency, along with operator confidence in maintaining visualisation of the probe tip, and hence we believe provides a valuable addition to the armamentarium of clinicians wishing to embark on performing RFA of thyroid nodules.


Subject(s)
Radiofrequency Ablation , Thyroid Nodule , Thyroid Nodule/surgery , Thyroid Nodule/diagnostic imaging , Thyroid Nodule/pathology , Humans , Radiofrequency Ablation/methods , Ultrasonography, Interventional/methods , Female , Catheter Ablation/methods
3.
Am J Transl Res ; 16(7): 3211-3219, 2024.
Article in English | MEDLINE | ID: mdl-39114719

ABSTRACT

OBJECTIVE: To analyze the efficacy of digital guide-assisted implant restoration technique in enhancing the anterior teeth aesthetics and its impact on labial bone mass. METHODS: We retrospectively analyzed clinical data from 90 patients who underwent maxillary anterior teeth implant restoration at The First People's Hospital of Fuyang, Hangzhou, from January 2021 to September 2023. The patients were divided into two groups: a conventional group (n=45, 45 implants, standard implant restoration) and a digital group (n=45, 45 implants, digital guide-assisted implant). We compared implant positional deviations, changes in dental plaque index (PLI), aesthetic effect scores, labial bone mass differences, and the occurrence of adverse reactions post-treatment between the two groups. RESULTS: The digital group exhibited significantly less deviation in root position in the buccolingual and vertical directions, less neck deviation in the buccolingual and vertical directions, and less apical deviation than the conventional group (P=0.021, P=0.005, P=0.016, P=0.008, P=0.026, respectively). Three months postoperatively, the digital group demonstrated a significantly lower mean PLI (P<0.001), higher white and pink aesthetic scores (P=0.021, P=0.005), and increased alveolar ridge height and coronal and middle labial bone mass (P=0.006, P=0.015, P=0.008). Additionally, this group experienced lower incidence of adverse reactions (4.44% vs. 17.78%) compared with the conventional group (P=0.044). CONCLUSION: The digital guide-assisted implant restoration significantly enhances implant accuracy, reduces bone resorption, improves aesthetic outcomes, and ensures higher safety.

4.
Ann Cardiol Angeiol (Paris) ; 73(4): 101792, 2024 Aug 07.
Article in French | MEDLINE | ID: mdl-39116643

ABSTRACT

We present the case of a 53-year-old patient with history of hypertension and dyslipidemia, admitted for effort-induced angina. Coronary angiography revealed two-vessel disease with severe stenosis of the LAD- Diagonal bifurcation (MEDINA 1-1-1). This lesion was considered complex regarding the severe stenosis of the bifurcation core, the angulation <45°, and the severity and length of the diagonal lesion. The procedure was planned according to a TAP technique. The flow in the diagonal was however lost after stenting the main vessel causing an ST elevation with chest pain. It was subsequently recovered using the rescue jailed balloon technique before re-crossing the stent struts of the LAD using a Gaia First® (Asahi) guidewire. The aim of this case report is to illustrate some pitfalls that can be encountered in bifurcation percutaneous interventions and to present technical solutions to solve difficult side branch access issues through a literature review.

5.
J Am Coll Radiol ; 2024 Aug 06.
Article in English | MEDLINE | ID: mdl-39117182

ABSTRACT

OBJECTIVE: To report data from the first three years of operation of the RSNA-ACR 3D Printing Registry. METHODS: Data from June 2020 to June 2023 was extracted, including demographics, indications, workflow and user assessments. Clinical indications were stratified by 12 organ systems. Imaging modalities, printing technologies and number of parts per case were assessed. Effort data was analyzed, dividing staff into provider and non-provider categories. The opinions of clinical users were evaluated through a Likert-scale questionnaire, and estimates of procedure time saved were collected. RESULTS: A total of 20 sites and 2,637 cases were included, consisting of 1,863 anatomic models and 774 anatomic guides. Mean patient age for models and guides was 42.4 ± 24.5 years and 56.3 ± 18.5 years respectively. Cardiac models were the most common type of models (27.2%), and neurologic guides were the most common type of guides (42.4%). Material jetting, vat photopolymerization and material extrusion were the most common printing technologies used overall (85.6% of all cases). On average, providers spent 92.4 minutes and non-providers spent 335.0 minutes per case. Providers spent most time on consultation (33.6 minutes), while non-providers focused most on segmentation (148.0 minutes). Confidence in treatment plans increased after using 3D printing (p<.001). Estimated procedure time savings for 155 cases was 40.5 ± 26.1 minutes. CONCLUSION: 3D printing is performed in healthcare facilities for many clinical indications. The registry provides insight into the technologies and workflows used to create anatomic models and guides, and the data shows clinical benefits from 3D printing.

6.
Ment Health Clin ; 14(4): 271-276, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39104438

ABSTRACT

Reporting interventions thoroughly and consistently in the literature allows for study reproducibility or implementation of the intervention into practice. Although there is currently no standard for describing Board-Certified Psychiatric Pharmacist (BCPP) interventions in the published literature, there are multiple checklists or guides that have been developed for reporting clinical interventions, including the template for intervention description and replication and the pharmacist patient care intervention reporting (PaCIR) checklist, that seek to improve the quality of reporting interventions in the literature. The purpose of this paper is to describe a proposed guide for reporting BCPP interventions in the literature by expanding the PaCIR checklist. Authors use a logic model developed by the American Association of Psychiatric Pharmacists to ensure all elements of the process are addressed in the expanded guide.

7.
Orthod Fr ; 95(2): 189-203, 2024 08 06.
Article in French | MEDLINE | ID: mdl-39106194

ABSTRACT

Introduction: Temporary Anchorage Devices have revolutionized our approach to anchorage management. However, their placement may carry risks, such as root perforation, damage to the periodontal ligament, buccal-nasal communication, etc. The aim of this article is to describe an original protocol in two times for the placement of a palatal mini-screw through guided surgery using a guide created by Computer-Aided Design and Manufacturing (CAD/CAM) followed by the transfer of placement information to the laboratory for the fabrication of a Custom Medical Device (CMD) for distalization. Materials and Methods: A two-stage protocol is described and illustrated step by step. Phase 1 comprises 7 steps (including superimposition of maxillary cast and profile teleradiography, surgical tray design), followed by phase 2, which involves 3 final steps (including production of impression for laboratory, production of laboratory model with transfer of mini-screw position). Results: Although the position of the mini screws remains precise, a discrepancy between the planning and the intraoral situation exists. The addition of a second step therefore enables the distalization appliance to be fitted precisely and without pitfalls. Finally, this protocol ensures safe placement, making work easier for the practitioner and, ultimately, for the patient. Conclusion: In a two-stage process, the placement of palatal mini screws through guided surgery using a guide created by CAD/CAM followed by the transfer of this information to the laboratory for the fabrication of a CMD for distalization proves to be a relevant approach.


Introduction: Les dispositifs d'ancrage temporaires ont révolutionné notre vision de la gestion de l'ancrage. En revanche, leur mise en place peut comporter certains risques (perforation radiculaire, communication bucco-nasale, lésions vasculaires…). Cet article vise à décrire un protocole original, en deux temps, de pose de mini-vis palatine par chirurgie guidée à l'aide d'un guide réalisé par conception et fabrication assistée par ordinateur (CFAO) in-office suivie du transfert des informations de pose au laboratoire pour la confection d'un appareil de distalisation. Matériel et méthodes: Un protocole en deux temps est décrit pas à pas. Le temps 1 comprend sept étapes (dont le placement virtuel des mini-vis et la création de la gouttière chirurgicale), suivi du temps 2 qui implique trois étapes (dont la réalisation de l'empreinte pour le laboratoire et l'élaboration du modèle de laboratoire avec transfert de la position des mini-vis). Résultats: Bien que la pose puisse être considérée comme précise, une différence existe entre la planification et la situation clinique. L'apport d'un second temps améliore l'adaptation de l'appareil de distalisation. Enfin, ce protocole offre une pose sécurisée et apporte ainsi un confort de travail pour le praticien et, in fine, pour le patient. Conclusion: Réalisée en deux temps, la pose de mini-vis palatine par chirurgie guidée à l'aide d'un guide réalisé par CFAO in-office suivie du transfert de cette information au laboratoire pour la confection d'un appareil de distalisation s'avère être une approche pertinente.


Subject(s)
Bone Screws , Computer-Aided Design , Maxilla , Molar , Orthodontic Anchorage Procedures , Humans , Orthodontic Anchorage Procedures/instrumentation , Orthodontic Anchorage Procedures/methods , Maxilla/surgery , Molar/surgery , Tooth Movement Techniques/methods , Tooth Movement Techniques/instrumentation , Palate/surgery , Orthodontic Appliance Design , Surgery, Computer-Assisted/methods
8.
Clin Neurol Neurosurg ; 245: 108471, 2024 Jul 26.
Article in English | MEDLINE | ID: mdl-39106636

ABSTRACT

OBJECTIVE: Although mechanical thrombectomy (MT) is primarily performed via transfemoral access (TFA), transradial access (TRA) is a potential alternative in older patients or those with tortuous vessels. However, the small radial artery diameter restricts the use of large-bore balloon guides and aspiration catheters, a limitation that may be overcome using the sheathless technique. Thus, we aimed to explore the feasibility, efficacy, and safety of sheathless TRA-MT as a first-line treatment approach for acute ischemic stroke. METHODS: This single-center retrospective case series included patients who underwent TRA-MT as first-line treatment between September 2020 and June 2023. Per our MT protocol, TRA was not the first-line approach in cases of left anterior circulation lesions with a type 3 aortic arch. We evaluated treatment effectiveness based on the successful recanalization rate, puncture-to-recanalization time, and modified first-pass effect; access route effectiveness based on the puncture-to-first-pass time and switch-to-TFA rate; and procedure safety based on procedure-related and severe puncture site complications. RESULTS: Sheathless 8-F guide catheters were used in 68 % and large-bore aspiration catheters in 70 % of the procedures. Successful recanalization was achieved in 98 % of the patients, with a modified first-pass effect in 54 % of them. The median puncture-to-first-pass and puncture-to-recanalization times were 20.5 and 33 min, respectively. The rate of procedure-related complications was low (4 %), with no severe puncture site complications. CONCLUSION: Sheathless TRA-MT enabled the use of large-bore guide and aspiration catheters, providing a swift approach to the target and satisfactory outcomes, and might be an effective first-line treatment for acute ischemic stroke.

9.
Mol Cell ; 2024 Jul 26.
Article in English | MEDLINE | ID: mdl-39096898

ABSTRACT

The IscB proteins, as the ancestors of Cas9 endonuclease, hold great promise due to their small size and potential for diverse genome editing. However, their activity in mammalian cells is unsatisfactory. By introducing three residual substitutions in IscB, we observed an average 7.5-fold increase in activity. Through fusing a sequence-non-specific DNA-binding protein domain, the eIscB-D variant achieved higher editing efficiency, with a maximum of 91.3%. Moreover, engineered ωRNA was generated with a 20% reduction in length and slightly increased efficiency. The engineered eIscB-D/eωRNA system showed an average 20.2-fold increase in activity compared with the original IscB. Furthermore, we successfully adapted eIscB-D for highly efficient cytosine and adenine base editing. Notably, eIscB-D is highly active in mouse cell lines and embryos, enabling the efficient generation of disease models through mRNA/ωRNA injection. Our study suggests that these miniature genome-editing tools have great potential for diverse applications.

10.
J Surg Case Rep ; 2024(8): rjae483, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39109375

ABSTRACT

A smile that reveals >4 mm of gum tissue is called a gummy smile (GS), offering negative impacts on people's self-confidence and aesthetic appearance. The treatment for GS should be planned according to underlying causes such as altered passive eruption of teeth, dentoalveolar extrusion, vertical maxillary excess, and short or hyperactive lip muscles. In this case report, a patient with severe GS received orthodontic and gingivoplasty treatment, aided by digital tools such as 3D simulation, smile design, and 3D printed guides. The treatment yielded remarkable and satisfactory results, without the need for extensive surgery. Our findings suggest that gingivoplasty is a minimally invasive, time- and cost-effective alternative to more extensive procedures for correcting severe gum recession.

12.
Article in English | MEDLINE | ID: mdl-39161990

ABSTRACT

Due to changes in pharmacokinetics and pharmacodynamics, patients with impaired renal function suffer an increased risk of suboptimal and potentially harmful medication treatment. This necessitates careful consideration of medications affected by impaired renal function when performing medication reviews. The aim of this study was to develop a quick guide (a list of recommendations) for assessing renal risk medications in medication reviews led by hospital pharmacists. The list was based on the 100 most frequently used medications in Danish hospitals and primary care. After combining the 200 records, 29 duplicates were excluded resulting in a pool of 171 medications. Assessment by two clinical pharmacists led to the exclusion of 121 medications. Of the remaining 50 medications, seven were discussed among the two pharmacists, and two of these were also in the research group to reach a consensus. The renal risk quick guide comprised 50 medications. The most prevalent medications on the list were from Anatomical Therapeutic Chemical Classification System (ATC)-group N, C and L. Recommendations from two databases were included in the quick guide in order to provide clinical pharmacists with existing, updated evidence on medication use in impaired renal function. The next step is to test the feasibility of the quick guide in daily practice when performing medication reviews.

13.
Gen Dent ; 72(5): 43-48, 2024.
Article in English | MEDLINE | ID: mdl-39151081

ABSTRACT

This study aimed to design a new surgical guide for controlling the mesiodistal distance between implant osteotomies and adjacent teeth as well as the osteotomy depth in partially edentulous patients. The guide kit was designed with design software and milled with a CNC (computer numerical control) router. The guide consisted of 2 components-stoppers and crown guides-for determining the drilling depth and mesiodistal position, respectively. The stoppers were designed in 7.5-, 9.5-, and 11.5-mm lengths, and the crown guides were fabricated with outer diameters of 5.0, 6.0, 7.0, and 8.0 mm. The accuracy of the guide was assessed by preparing a total of 20 implant osteotomies in 4 partially edentulous models and comparing the dimensions of the actual osteotomies to the values that were predicted to occur with the use of the surgical guides. Osteotomies were prepared using the 7.5-mm stopper with either the 7.0- or 8.0-mm crown guide. Cone beam computed tomography (CBCT) was used to obtain images for analysis of osteotomy-tooth mesiodistal distances, which were predicted to be 3.0 or 5.5 mm, depending on position; interosteotomy mesiodistal distances, which were predicted to be 3.0 mm; and osteotomy depth, which was predicted to be 11.5 mm. A 1-sample t test was used to determine if there were significant differences between the predicted values and the measurements of the guided osteotomies on the CBCT images of the mandibular models, and an independent t test was conducted to compare the results of 3.0- and 5.5-mm osteotomy-tooth distances (α = 0.05). Differences between the predicted and actual values of the interosteotomy mesiodistal distance (P = 0.516) and osteotomy depth (P = 0.847) were not statistically significant. The actual osteotomy-tooth mesiodistal distances were significantly different from the predicted values of 3.0 (P = 0.000) and 5.5 mm (P = 0.001), with higher mean differences of 0.46 and 0.60 mm, respectively. The designed guide had a high accuracy in achieving optimal linear interosteotomy mesiodistal distances and osteotomy depths, and the obtained mean values were clinically acceptable.


Subject(s)
Cone-Beam Computed Tomography , Dental Implantation, Endosseous , Humans , Dental Implantation, Endosseous/methods , In Vitro Techniques , Dental Implants , Osteotomy/methods , Osteotomy/instrumentation , Surgery, Computer-Assisted/methods , Jaw, Edentulous, Partially/surgery , Jaw, Edentulous, Partially/diagnostic imaging , Computer-Aided Design , Software , Models, Dental
14.
J Mol Biol ; : 168745, 2024 Aug 13.
Article in English | MEDLINE | ID: mdl-39147126

ABSTRACT

Argonaute nucleases use small nucleic acid guides to recognize and degrade complementary nucleic acid targets. Most prokaryotic Argonautes (pAgos) recognize DNA targets and may play a role in cell immunity against invader genetic elements. We have recently described two related groups of pAgo nucleases that have distinct specificity for DNA guides and RNA targets (DNA>RNA pAgos). Here, we describe additional pAgos from the same clades of the pAgo tree and demonstrate that they have the same unusual nucleic acid specificity. The two groups of DNA>RNA pAgos have non-standard guide-binding pockets in the MID domain and differ in the register of guide DNA binding and target cleavage. In contrast to other pAgos, which coordinate the 5'-end of the guide molecule by their C-terminal carboxyl, DNA>RNA pAgos have an extended C-terminus located away from the MID pocket. We show that modifications of the C-terminus do not affect guide DNA binding, but inhibit cleavage of complementary and mismatched RNA targets by some DNA>RNA pAgos. Our data suggest that the unique C-terminus found in DNA>RNA pAgos can modulate their catalytic properties and can be used as a target for pAgo modifications.

15.
J Esthet Restor Dent ; 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-39145491

ABSTRACT

OBJECTIVE: The principal aim of this report is to address the challenge of integrating prosthetic crowns with natural dentition in the esthetic zone. It highlights the utilization of a prosthetically driven treatment plan, designed to ensure predictable esthetic outcomes. CLINICAL CONSIDERATIONS: This report details a technique that utilizes three digital guides, all derived from a 3-dimensional digital smile design. The integration of a restoration guide, an implant drilling guide, and an alveoloplasty guide is described. These tools collectively facilitate the precise execution of both surgical and prosthetic procedures, enhancing treatment accuracy and esthetic integration. CONCLUSIONS: This technique considers the esthetic prosthetic crowns, implant positions, and alveoloplasty collectively. It enhances the predictability of esthetic outcomes in oral implantology and potentially provides an integrated prosthetically driven workflow in cosmetic dental treatments. CLINICAL SIGNIFICANCE: The application of multiple digital guides derived from the same prosthetically driven treatment significantly enhances the predictability of esthetic outcomes in oral implantology.

16.
Aesthetic Plast Surg ; 2024 Aug 12.
Article in English | MEDLINE | ID: mdl-39134680

ABSTRACT

BACKGROUND: Mandibular genioplasty, a central procedure in oral and maxillofacial surgery, has traditionally relied on surgeon experience with potential limitations in precision. The advent of digital methods, particularly computer-aided design/computer-aided manufacturing (CAD/CAM), offers a promising alternative. This study aims to evaluate the efficacy of digital surgical guides in improving the precision of mandibular genioplasty. METHODS: A prospective analysis of 50 patients undergoing genioplasty was performed, 30 in the experimental group using digital surgical guides and 20 in the control group using traditional methods. Three-dimensional reconstructions were obtained using cone-beam computed tomography (CBCT) and digital scans. Osteotomy guides were 3D-printed based on group assignment. Postoperatively, accuracy was assessed by measuring distances between landmarks. RESULTS: The experimental group showed significantly reduced horizontal positioning errors in genioplasty advancement, with no significant differences in vertical errors. For genioplasty retraction, the experimental group showed fewer vertical positioning errors, while horizontal errors remained consistent. CONCLUSIONS: The use of digital surgical guides in mandibular genioplasty significantly improves surgical accuracy, resulting in improved outcomes and patient satisfaction. This study highlights the potential of digital methods in refining oral and maxillofacial surgical procedures. LEVEL OF EVIDENCE III: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.

17.
Arthroplast Today ; 27: 101374, 2024 Jun.
Article in English | MEDLINE | ID: mdl-39071821

ABSTRACT

The direct anterior approach (DAA) has been increasing in popularity for primary total hip arthroplasty (THA). Despite previously documented anatomic limitations to its direct distal extension, alternative exposure methods have been described to safely access the femoral diaphysis and facilitate increasingly complex primary and revision THA scenarios. The DAA has several purported advantages compared to alternative approaches (eg, posterior and lateral-based), including its muscle-sparing nature, use of an internervous plane, and preservation of posterior stabilizing structures. Proponents of the DAA cite decreased postoperative pain, quicker recovery times, potentially lower dislocation rates, ease of intraoperative fluoroscopy, and improved implant placement/restoration of leg lengths. The current literature, however, is sparse when considering the use of this approach in the setting of severely dysplastic hips necessitating a concurrent subtrochanteric shortening osteotomy. When utilizing a posterior approach in this population, previous work from Ollivier and colleagues demonstrated high rates of cementless implant osseointegration and significantly improved clinical outcomes at long-term follow-up. Although relatively few reports of addressing this pathology via the DAA currently exist, initial results are promising. This study seeks to provide a detailed description of a surgical technique for performing primary THA and ipsilateral subtrochanteric shortening osteotomy in this patient population utilizing an extensile DAA.

18.
Arthroplast Today ; 27: 101361, 2024 Jun.
Article in English | MEDLINE | ID: mdl-39071838

ABSTRACT

Background: Many techniques and technologies exist for the intraoperative assessment of component positioning, leg lengths, and offset in total hip arthroplasty, but with limited comparative data. We conducted a systematic review of the available literature to evaluate the range of techniques and technologies for the intraoperative assessment of component position as well as leg lengths and offset in terms of accuracy, precision, surgical time, cost, and relationship to clinical outcomes. Methods: A comprehensive search of the Embase and Medline databases from 1974 to 2023 was performed. We included controlled or comparative prospective clinical studies. Cochrane's risk-of-bias tool for randomized trials and Risk of Bias in Non-Randomized Studies - of Interventions tools were used by 2 independent reviewers to evaluate each study for risk of bias. We conducted both qualitative and quantitative analyses of the studies included. However, a meta-analysis was deemed not to be feasible due to heterogeneity. Results: Our review included 25 studies with 52 intraoperative techniques and technologies. Mechanical guides and computerized navigation were most frequently evaluated in the included studies. Computerized navigation systems consistently showed the greatest accuracy and precision across all measures, at the cost of longer mean operative time. In contrast, freehand techniques demonstrated the poorest accuracy and precision. Insufficient data were found to reach any meaningful conclusions in terms of differences in overall surgical cost or clinical outcomes. Conclusions: Evidence shows that computerized navigation systems are most accurate and precise in positioning components during total hip arthroplasty. Further research is needed to determine their health and economic impact and whether the accuracy and precision of navigated techniques are justified in terms of clinical outcomes.

19.
Waste Manag Res ; : 734242X241261998, 2024 Jul 23.
Article in English | MEDLINE | ID: mdl-39044452

ABSTRACT

Global waste management challenges demand innovative and multi-functional solutions. The Nordic Biogas Model (NBM) based on anaerobic digestion of organic waste and valorization of its outputs provides several benefits beyond waste treatment such as energy recovery, nutrient recycling and climate impact mitigation. Despite these benefits, its international adoption remains limited, revealing an implementation gap. One way to address this gap is to adapt technology and knowledge from the provider to each specific context. This involves the embedding of the technology into the local context and the development of conditions such as formal and informal institutions over time. Based on decade-long interactions with Nordic companies and municipal decision-makers, we highlight the importance of communication between the technology provider and potential adopter, to ensure that the diverse sustainability benefits of NBM are acknowledged. Furthermore, most provider companies can benefit from a systematic guideline that supports early-stage decision-making as an essential component of the adaptation and implementation of the NBM in diverse international contexts. In this article, we offer suggestions for both: (1) how to better communicate the sustainability benefits of the NBM, and (2) how to assess the risk and opportunities of entering new markets at the early stages of decision-making.

20.
J Cosmet Dermatol ; 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-39037906

ABSTRACT

BACKGROUND: Patients can have different reasons for seeking cheek augmentation; while some are in need of volume augmentation, others may request projection and lifting. A treatment guide can be useful for treating clinicians in choosing the most suitable product. AIMS: This 8-week, multicenter study was conducted to evaluate the effectiveness and safety of cheek augmentation using a treatment guide to choose between study products HACON and HALYF. PATIENTS/METHODS: Female subjects intending to undergo cheek augmentation were treated according to primary need for treatment-HACON for contouring or HALYF for projection. Treatments were performed according to approved labels. Assessments included Global Aesthetic Improvement Scale (GAIS) evaluations, subject satisfaction, subject-perceived age (FACE-Q), naturalness of facial expressions, 3D imaging analysis, and safety assessments. RESULTS: All subjects (n = 60) were assessed as aesthetically improved by the investigators 4 and 8 weeks after last injection. For all subjects, contouring or projection was achieved as planned with natural-looking results. Subject satisfaction was high in both study groups. Volume change of the cheek area was statistically significant from baseline to Week 4 (p < 0.001), in both treatment groups and on both sides of the face. Overall, treatments were well tolerated with mainly mild adverse events related to treatment. CONCLUSIONS: The proposed guide for product selection of HACON or HALYF for treatment of the cheek area was useful to achieve the primary treatment goal for both products. Treatments were well tolerated and associated with improved aesthetic appearance of the cheeks as well as high subject satisfaction.

SELECTION OF CITATIONS
SEARCH DETAIL