Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 78
Filter
1.
Article in English | MEDLINE | ID: mdl-39126286

ABSTRACT

PURPOSE: This study aims to perform a network meta-analysis of hamstring graft preparation techniques to enhance anterior cruciate ligament (ACL) reconstruction guidelines and inform clinical decision-making in patients with primary ACL rupture. METHODS: A review of the literature, from 1 January 1990, to 31 August 2023, was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, focusing on the clinical outcomes of various hamstring graft preparation techniques. Forty-six studies (over 4800 knees) were analysed. Eight graft compositions: doubled hamstring (ST/G)-1978 grafts, doubled hamstring with augmentation (ST/G+A)-586 grafts, tripled semitendinosus (3ST)-124 grafts, quadrupled semitendinosus (4ST)-1273 grafts, five-strand tripled semitendinosus + doubled gracilis (3ST/2GR-839 grafts, six-strand tripled semitendinosus + tripled gracilis (3ST/3GR)-335 grafts, seven-strand quadrupled semitendinosus + tripled gracilis (4ST/3GR)-11 grafts and ≥eight strands-24 grafts were compared, considering graft sizes, laxity, muscle strength, range-of-motion, patient-reported outcome measures (PROMs), return to sport (RTS) and adverse events. RESULTS: The 4ST grafts fared better than the ST/G grafts in the International Knee Documentation Committee (IKDC), Knee Injury and Osteoarthritis Outcome Score (KOOS) Sport, KOOS Q and RTS (mean difference [MD], -1.69; p = 0.0159; MD, -1.55; p = 0.0325; MD, -1.93; p = 0.001; odds ratio: 3.13; p < 0.0001). The IKDC differed significantly between the 4ST and ST/G+A groups (MD, 1.88; p = 0.046). The ST/G+A resulted in the lowest knee laxity, surpassing the ST/G, 3ST and 4ST. The ST/G had the smallest diameter (ST/G vs. ST/G+A: MD, 1.26; 95% confidence interval [CI]: 0.67-1.86, p < 0.0001). Reduced failure rates were noted with the 3ST/2GR (3ST/2GR vs. ST/G: MD, 6.93; p = 0.009) and 3ST/3GR (3ST/3GR vs. ST/G: MD, 53.64; p = 0.006). CONCLUSION: The ideal hamstring graft for ACLR should be individualized. A 4ST graft is likely to yield good PROMs. For high stability and rapid RTS, adding augmentation to the graft is advisable. The ST/G is the thinnest graft possible. LEVEL OF EVIDENCE: Network meta-analysis of level I-III studies.

2.
Cureus ; 16(5): e60239, 2024 May.
Article in English | MEDLINE | ID: mdl-38872693

ABSTRACT

Background This study investigates the functional outcomes of single-bundle arthroscopic anterior cruciate ligament (ACL) reconstruction, comparing the use of two distinct graft sources: peroneus longus (PL) graft and hamstring graft. The choice of graft material in ACL reconstruction is crucial for optimal postoperative results, and this study aims to contribute valuable insights into the comparative efficacy of these two graft types. Method This open-label randomized comparative study involved a carefully selected cohort of patients undergoing single-bundle arthroscopic ACL reconstruction. Participants were randomly assigned to either the PL graft group or the hamstring graft group. Surgical procedures were conducted using standardized techniques, and postoperative rehabilitation protocols were closely monitored. Functional outcomes, including range of motion, stability, and patient-reported measures, were assessed at predefined intervals to ensure comprehensive data collection. Results The study underscores significant demographic and clinical factors in ACL reconstruction outcomes. Participants were predominantly aged 17-30 years (58.33%) with a mean age of 29.27 years and exhibited a male predominance (80.56%). Common complaints included knee pain and instability, primarily due to falls from bikes (55.56%) or sports-related trauma (44.44%). Notably, PL grafts demonstrated advantages over hamstring grafts, with longer mean length (10.11 mm vs. 8.77 mm, p=0.0001) and shorter operation times. Visual analog scale (VAS), International Knee Documentation Committee (IKDC), and Tegner Lysholm scores show no significant differences between grafts over the period of time. There is no notable foot eversion weakness or significant donor site morbidity after the PL graft harvest. Hamstring graft cases exhibit a higher incidence of altered sensation and muscle atrophy, suggesting the potential benefits of PL grafts for improved surgical outcomes. Conclusions Graft comparisons favored PL grafts due to longer length, and functional outcome assessments between the two graft types. However, foot and ankle strength assessments revealed fluctuations in strength recovery with PL grafts, highlighting the need for tailored rehabilitation. Thigh circumference variations suggested potential muscle atrophy in the hamstring graft group, along with reported paresthesia in the ipsilateral proximal leg. In conclusion, PL grafts offer potential advantages for ACL surgery, but ongoing monitoring and specialized rehabilitation are crucial.

3.
Shoulder Elbow ; 16(3): 274-284, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38818097

ABSTRACT

Introduction: Winging of the scapula occurs due to dysfunction of its stabilising muscles, most commonly serratus anterior and/or trapezius, for example in facioscapulohumeral muscular dystrophy. Resultant loss of scapular control and abnormal kinematics can decrease shoulder function due to glenohumeral joint instability, loss of range of motion and pain. Previously described treatment for cases resistant to physiotherapy includes scapulothoracic arthrodesis which involves risk of non-union and metalwork failure, as well as reduced respiratory function due to immobilisation of a segment of the adjacent chest wall. Technique: We present a novel surgical approach to the management of problematic scapular winging by using hamstring graft to achieve a scapulothoracic tenodesis. Discussion: We believe this technique provides an adequately stable scapula for improved shoulder movement and function, a sufficiently mobile chest wall for improved lung function and avoidance of complications specifically associated with arthrodesis.

4.
J Sport Rehabil ; 33(5): 317-324, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38684207

ABSTRACT

CONTEXT: The persistence and the recurrence of posterior medial knee pain (PKP) after anterior cruciate ligament reconstruction (ACLR) using hamstring tendon graft are often overlooked during rehabilitation. DESIGN: Cross-sectional observational study. METHODS: The study aimed (1) to evaluate the prevalence of these types of PKP before 4 months post-ACLR, (2) to measure their consequences on the knee flexors strength, and (3) to evaluate the role of the type of ACLR. From a cohort of patients operated on with hamstring tendon procedures, the persistent and the recurrent PKP were sought at 4 months post-ACLR. The evolution of isokinetic muscle strength recovery in PKP subjects was compared with those of nonpainful subjects. The functional deficit was measured at 6/7 months post-ACLR by a hop test. RESULTS: Three hundred seventeen subjects (25.8 [6.0] y) were included. At 4 months post-ACLR, 2 populations were identified based on the recurrent onset of PKP (PKP+, n = 40) or the absence of knee pain (PKP-, n = 277). The prevalence of PKP was 8.3%. At the fourth month post-ACLR, the PKP+ group had a higher flexor strength deficit compared with the PKP- group (limb symmetry index at 60°/s: 67.2% [12.4%] vs 84.3% [12.6%]; P < .05). At 6/7 months, the loss of strength persisted (limb symmetry index at 60°/s: 82.3% [13.4%] vs 87.7% [12.8%]; P < .05). The hop test deficit was comparable, and no difference was shown according to the type of graft. CONCLUSIONS: Persistent and recurrent PKP during the rehabilitation period were not uncommon and were associated with a worsening of flexors strength loss on the ACLR side.


Subject(s)
Anterior Cruciate Ligament Reconstruction , Muscle Strength , Humans , Anterior Cruciate Ligament Reconstruction/rehabilitation , Muscle Strength/physiology , Cross-Sectional Studies , Male , Female , Adult , Young Adult , Recurrence , Hamstring Tendons/transplantation
5.
Knee Surg Sports Traumatol Arthrosc ; 32(6): 1414-1422, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38566538

ABSTRACT

PURPOSE: Risk factors for the development of symptomatic cyclops lesion after anterior cruciate ligament reconstruction (ACLR) surgery are not entirely identified yet. This study aimed to investigate whether the choice of hamstring graft (semitendinosus-gracilis; STG vs. semitendinosus; ST) affects the risk of developing a symptomatic cyclops lesion after ACLR. METHODS: This retrospective cohort study included 1416 patients receiving either an ST graft (n = 1209) or an STG graft (n = 207) ACLR with a follow-up of at least 2 years. A persisting extension limitation was clinically determined, and cyclops lesions were confirmed by magnetic resonance imaging (MRI) and second-look arthroscopy. Graft-specific incidence of cyclops lesions was examined with χ2 test and combined with the factors number of graft bundles, graft diameter and sex evaluated with a binominal logistic regression model. RESULTS: In total, 46 patients developed symptomatic cyclops lesions (3.2%), with 36 having ACLR with an ST graft (3.0%) and 10 with an STG graft (4.8%) (n.s). The mean time from ACLR to the second-look arthroscopy for cyclops removal was 1.1 ± 0.6 years. Female patients were 2.5 times more likely to develop a cyclops lesion than male patients. Patients with an STG graft and larger graft diameters did not have a higher risk of developing cyclops lesions. Patients who received an STG graft with both tendons folded four times (double-quadruple) had significantly higher risk of developing a cyclops compared with all other numbers of graft bundles combined (8.3%, respectively 3.0%; p = 0.014). CONCLUSION: This study could not prove an increased risk of developing a symptomatic cyclops lesion for patients with an STG graft compared with an ST graft used for ACLR. However, patients with a double-quadruple ACLR had a higher percentage of cyclops lesions compared with all other numbers of graft bundles. Female sex was associated with an increased risk of developing cyclops lesions. LEVEL OF EVIDENCE: Level III.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament Reconstruction , Arthroscopy , Magnetic Resonance Imaging , Postoperative Complications , Humans , Anterior Cruciate Ligament Reconstruction/adverse effects , Female , Retrospective Studies , Male , Adult , Sex Factors , Incidence , Anterior Cruciate Ligament Injuries/surgery , Anterior Cruciate Ligament Injuries/epidemiology , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Risk Factors , Hamstring Tendons/transplantation , Young Adult , Gracilis Muscle/transplantation , Adolescent
6.
Am J Sports Med ; 52(2): 535-543, 2024 02.
Article in English | MEDLINE | ID: mdl-36876736

ABSTRACT

BACKGROUND: Because grafts are made in 0.5-mm increments clinically for anterior cruciate ligament (ACL) reconstruction, it is important to clarify how the failure rate decreases as the diameter increases. Moreover, it is important to know whether even a slight increase in the graft diameter decreases the risk of failure. HYPOTHESIS: The risk of failure decreases significantly with each 0.5-mm increase in hamstring graft diameter. STUDY DESIGN: Meta-analysis; Level of evidence, 4. METHODS: The systematic review and meta-analysis have estimated the diameter-specific failure risk for each 0.5-mm increase in ACL reconstruction using autologous hamstring grafts. We searched for studies describing the relationship between graft diameter and failure rate published before December 1, 2021, in leading databases, such as PubMed, EMBASE, Cochrane Library, and Web of Science, according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. We included studies using single-bundle autologous hamstring grafts to investigate the relationship between failure rate and graft diameter of 0.5-mm intervals with >1-year follow-up. Then, we calculated the failure risk caused by 0.5-mm differences in autologous hamstring graft diameter. Assuming Poisson distribution for the statistical model, we employed an extended linear mixed-effects model in the meta-analyses. RESULTS: Five studies containing 19,333 cases were eligible. The meta-analysis revealed that the estimated value of the coefficient of diameter in the Poisson model was -0.2357 with a 95% CI of -0.2743 to -0.1971 (P < .0001). With every 1.0-mm increase in diameter, the failure rate decreased by 0.79 (0.76-0.82) times. In contrast, the failure rate increased by 1.27 (1.22-1.32) times for each 1.0-mm decrease in diameter. The failure rate significantly decreased with each 0.5-mm increase in graft diameter in the range of <7.0 to >9.0 mm from 3.63% to 1.79%. CONCLUSION: The risk of failure decreased correspondingly with each 0.5-mm increase in graft diameter in the range of <7.0 to >9.0 mm. Failure is multifactorial; however, increasing the graft diameter as much as possible to match each patient's anatomic space without overstuffing is an effective precaution that surgeons can take to reduce failures.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament Reconstruction , Hamstring Muscles , Hamstring Tendons , Humans , Transplantation, Autologous , Anterior Cruciate Ligament Injuries/surgery , Autografts/surgery , Hamstring Muscles/surgery , Hamstring Tendons/transplantation
7.
Eur J Orthop Surg Traumatol ; 34(1): 67-73, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37644333

ABSTRACT

PURPOSE: Evaluate the outcomes of ACL (Anterior Cruciate Ligament) reconstruction techniques that use a hamstring graft with a preserved tibial insertion and compare them to standard techniques. METHODS: A systematic literature review and meta-analysis was done of the PubMed, MEDLINE, Cochrane and Ovid databases to identify published clinical studies on ACL reconstruction in which a non-detached hamstring tendon (NDHT) was used as a graft and to compare them to studies in which a detached hamstring tendon (DHT) or other techniques were used. The eligible studies were analyzed for the knee laxity, Lachman test, pivot shift test, joint range of motion, anterior drawer, pain, re-tear, revision surgery, Lysholm score, Tegner score, ACL-RSI scale, KOOS, IKDC, SNQ and Howell scale. RESULTS: Twelve articles in which NDHT was used for ACL reconstruction were analyzed. There was no significant difference between NDHT and DHT in the Lachman > 1 (p = .07), pivot shift test > 1 (p = .40), re-tears (p = .62), pain (p = .85) and the Tegner score (p = .95). However, the outcomes were somewhat better with the NDHT technique for the Lachman (RR = 0.30; 95% CI 0.08-1.12), pivot shift test (RR = 0.50; 95% CI 0.10-2.49) and re-tears (RR = 0.66; 95% CI 0.13-3.42). The other criteria were not included in the meta-analysis because of lack of data or because specific outcome scores were used in each article. CONCLUSION: NDHT techniques provide similar results to DHT for ACL reconstruction and tend to produce better stability and a lower re-tear rate.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament , Humans , Anterior Cruciate Ligament/surgery , Anterior Cruciate Ligament Injuries/surgery , Knee Joint/surgery , Pain , Treatment Outcome
8.
J Orthop ; 50: 130-134, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38156024

ABSTRACT

Background: Prediction of hamstring tendon autografts is essential when planning a ligament reconstruction surgery. This is especially important in cases of multiple ligament reconstruction surgeries. This study was designed to predict the dimensions of 5-stranded hamstring grafts from anthropometric parameters in patients undergoing anterior cruciate ligament (ACL) reconstruction surgery. Methods: 172 patients undergoing ACL reconstruction with hamstring autografts were included in the study. Preoperative parameters included age, gender, height, weight, body mass index (BMI), thigh length, thigh circumference, and tibia length; intraoperative parameters included semitendinosus (ST) and gracilis (G) length and diameter, final 5-stranded graft length and diameter. Pre-operative data was correlated with intra-operative data using tests of significance. Results: Height, tibia and thigh length were greater in males (p < 0.05) whereas BMI was greater in females (p < 0.05). G and ST length alongwith 5-stranded graft length and diameter were significantly greater in males (p < 0.05). The graft dimensions could be correlated with the pre-operative anthropometric parameters using specific equations. This was applicable to the lengths and diameters of ST, G and 5-stranded grafts. We also noted that an increase in age was associated with a reduction in graft dimensions except for the diameter of G graft in females and length of 5-stranded grafts in males. Conclusion: 5-stranded hamstring graft dimensions can be reliably predicted using anthropometric parameters and this eases surgical planning.

9.
SICOT J ; 9: 34, 2023.
Article in English | MEDLINE | ID: mdl-38032265

ABSTRACT

PURPOSE: Graft diameter in anterior cruciate ligament reconstructions has been shown to influence the risk of failure. It is therefore important to be able to adjust the graft configuration to modify the diameter. To measure the impact of a 6-strand (6S) hamstring autograft configuration on graft diameter compared to the standard 4-strand (4S) configuration. METHODS: Cadaveric study on 33 knees, using the usual hamstring graft harvesting technique. Semitendinosus and gracilis tendons were harvested and their length, width, and diameter were measured in 4S and 6S configurations separately by three evaluators. RESULTS: 6S configuration leads to a median increase of 1.5 (range: 0.0-2.0) mm in diameter compared to 4S (p < 0.001). A graft diameter of more than 8 mm is attained in less than a third of 4S grafts within this population in comparison to 84% when the 6S configuration is used. DISCUSSION: The 6S hamstring graft configuration increases the graft diameter by a median of 1.5 millimeters compared to the traditional 4S configuration. It can reliably be used to obtain an 8.5 mm graft diameter or more in cases where the semitendinosus measures at least 270.5 mm and the 4S configuration has a diameter of 7.5 mm or 8 mm. This information helps to better delineate the impact of a 6S configuration in a pre-operative or intra-operative setting to optimize the decisional process and surgical flow and to easily adapt the graft diameter. LEVEL OF EVIDENCE: V (cadaveric study).

10.
J Nepal Health Res Counc ; 21(1): 34-39, 2023 Sep 08.
Article in English | MEDLINE | ID: mdl-37742146

ABSTRACT

BACKGROUND: The purpose of this study is to determine whether preoperative magnetic resonance image measurements can predict the hamstring tendon autograft diameter during anterior cruciate ligament reconstruction. METHODS: We prospectively evaluated Forty-two patients with anterior cruciate ligament injury who underwent reconstruction using hamstring tendon autograft. Preoperative diameters and cross-sectional areas of the hamstring tendons were estimated using magnetic resonance imaging of the knee. Intraoperative diameters of the hamstring tendon graft were measured using a cylindrical graft sizer. We used Pearson's correlation test to compare the Preoperative and intraoperative graft size measurements. A possible cutoff value for the hamstring graft size was determined using Receiver operating characteristic analysis. RESULTS: The mean age of the patient in the study was 27.5 ± 8.5 years. There were statistically significant correlations between preoperative and intraoperative hamstring tendon graft measurements (P < 0.001). Our study found 13.3 mm² cross-sectional area as the cutoff for predicting 7mm of quadrupled hamstring graft size with both sensitivity and specificity of 85.7 %, respectively. CONCLUSIONS: We can conclude that preoperative magnetic resonance imaging measurements can predict the intraoperative graft size. This study can help in preoperatively planning for the graft choice.

11.
J Orthop Case Rep ; 13(1): 12-17, 2023 Jan.
Article in English | MEDLINE | ID: mdl-37143560

ABSTRACT

Introduction: Anterior cruciate ligament (ACL) injury is the common knee injury consequent to contact sports. There are different techniques recommended for the ACL reconstruction, with different graft materials. The aim of this study is to evaluate the functional outcome of arthroscopic single bundle ACL reconstruction using hamstring tendon graft in ACL deficient knees in adults. Materials and Methods: Between 2014 and 2017, a prospective study was conducted in Thanjavur Medical College on 10 ACL deficient patients. All patients were evaluated preoperatively using the Lysholm and Gillquist score and IKDC - 2000 score. All patients underwent arthroscopic single bundle ACL reconstruction with hamstring tendon graft, which was fixed with an endo-button CL fixation system on the femoral side and an interference screw on tibial side. They were advised a regular rehabilitation protocol. All patients were evaluated post-operatively at 6 weeks, 3 months, 6 months, and a year by same assessment scores. Results: Ten patients were available for follow up for a period of 6 months to 2 years. The mean follow-up period was 10.5 months. When compared with their respective pre-operative knee assessment scores, it was found that a definite improvement was there in their knee function. The results were good to excellent in 80% patients, fair in 10%, and poor in 10% cases. Conclusion: For young active adults, single bundle reconstruction by arthroscopic methods gives acceptable results. The problems which are faced post-operatively can be again settled arthroscopically. A long-term follow-up of these cases is a must to analyze if there is degeneration that happened in the time between injury and ligament reconstruction.

12.
Knee Surg Sports Traumatol Arthrosc ; 31(8): 3465-3473, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37140654

ABSTRACT

PURPOSE: Hamstring autograft (HA) is commonly used for primary anterior cruciate ligament reconstruction (ACLR). However, if the harvested HA is inadequate in diameter, it is often augmented with an allograft tendon, forming a hybrid graft (HY). This study sought to evaluate aseptic revision risk following HA versus HY ACLR. METHODS: A retrospective cohort study was performed using data obtained from our healthcare system's ACLR registry. Patients ≤ 25 years of age who underwent primary isolated ACLR were identified (2005-2020). Graft type and diameter size was the primary exposure of interest: < 8 mm HA and ≥ 8 mm HY. A secondary analysis was performed to examine 7 mm HA and 7.5 mm HA vs ≥ 8 mm HY. Propensity score-weighted Cox proportional hazard regression was used to evaluate the risk of aseptic revision. RESULTS: The study sample included 1,945 ACLR: 548 ≥ 8 mm HY, 651 7 mm HA, and 672 7.5 mm HA. The crude cumulative aseptic revision probability at 8-years for ≥ 8 mm HY was 9.1%, 11.1% for 7 mm HA, and 11.2% for 7.5 mm HA. In adjusted analysis, no difference in revision risk was observed for < 8 mm HA (hazard ratio [HR] 1.15, 95% confidence interval [CI] 0.72-1.82), 7 mm HA (HR 1.23, 95% CI 0.71-2.11), or 7.5 mm HA (HR 1.16, 95% CI 0.74-1.82) compared to ≥ 8 mm HY. CONCLUSION: In a US-based cohort of ACLR patients aged ≤ 25 years, we failed to observe any differences in aseptic revision risk for HA < 8 mm compared to HY ≥ 8 mm. Augmentation of a HA as small as 7 mm is not necessary to prevent a revision surgery. LEVEL OF EVIDENCE: Level III.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament Reconstruction , Hamstring Tendons , Humans , Adult , Retrospective Studies , Anterior Cruciate Ligament Injuries/surgery , Anterior Cruciate Ligament Reconstruction/adverse effects , Transplantation, Homologous , Transplantation, Autologous/adverse effects , Reoperation , Hamstring Tendons/transplantation , Autografts/surgery
13.
Am J Sports Med ; 51(8): 2064-2072, 2023 07.
Article in English | MEDLINE | ID: mdl-37204156

ABSTRACT

BACKGROUND: The semitendinosus (ST) tendon can be used by itself as a graft for anterior cruciate ligament (ACL) reconstruction. An increasing number of these procedures are being done while preserving the ST's tibial attachment, but there are no data on the remodeling of an attached ST (aST) graft. PURPOSE: To compare graft remodeling on magnetic resonance imaging (MRI) scans at 1 year after ACL reconstruction between standard free ST graft and aST graft. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: This prospective study enrolled 180 patients who were undergoing ACL reconstruction: 90 with the ST graft and 90 with the aST graft. The analysis was performed 1 year after the surgery. The main endpoint was the signal-to-noise quotient (SNQ) on MRI scans (T1-weighted sequence). The secondary endpoints were tibial tunnel widening (TTW), graft maturation (Howell classification), retear rate, new surgery rate, Simple Knee Value, Lysholm score, International Knee Documentation Committee (IKDC) score, postoperative Tegner score, difference between pre- and postoperative Tegner scores, ACL-Return to Sport after Injury (ACL-RSI), return-to-sports rate, and time to return to sports. RESULTS: The mean adjusted SNQ was 1.18 (95% CI, 0.72-1.65) in the aST group and 3.88 (95% CI, 3.42-4.34) in the ST group (P < .001). The new surgery rate was 2.2% in the aST group and 10% in the ST group (P = .029). The median Lysholm score was significantly higher in the aST group (99; interquartile range [IQR], 95-100) than in the ST group (95; IQR, 91-99) (P = .004). The mean time to return to sports was significantly shorter in the aST group (248.73 ± 141.62 days) than the ST group (317.23 ± 144.69 days) (P = .002). No statistically significant difference was found between groups in the TTW (P = .503), Howell graft maturity grade (P = .149), retear rate (P > .999), Simple Knee Value (P = .061), postoperative Tegner score (P = .320), pre- to postoperative difference in Tegner score (P = .317), ACL-RSI (P = .097), IKDC score (P = .621), and return-to-sports rate (P > .999). CONCLUSION: At 1 year postoperatively, remodeling of an ST graft assessed using MRI is better when its distal attachment is left intact.


Subject(s)
Anterior Cruciate Ligament Injuries , Hamstring Muscles , Humans , Cohort Studies , Anterior Cruciate Ligament Injuries/diagnostic imaging , Anterior Cruciate Ligament Injuries/surgery , Prospective Studies , Knee Joint/surgery
14.
Knee Surg Sports Traumatol Arthrosc ; 31(5): 1723-1732, 2023 May.
Article in English | MEDLINE | ID: mdl-35737010

ABSTRACT

PURPOSE: Button implants with an adjustable-loop device (ALD) are often used in anterior cruciate ligament reconstruction (ACLR). Clinical research comparing ALDs with fixed-loop devices (FLD) has mainly been conducted in small patient populations with short follow-up times. To determine whether ALDs are safe to use in ACLR, a non-inferiority study with a large sample population and a long follow-up period would be beneficial. This study compared ALDs with FLDs to determine non-inferior revision surgery rates, knee stability, and patient-reported outcomes (PROM) in ACLRs. METHODS: This non-inferiority register-based cohort study was conducted using data from the Danish Knee Ligament Reconstruction Registry (DKRR). A total of 12,723 patients > 15 years of age with primary ACLR using hamstring tendon autografts and either an FLD or ALD for femoral fixation were included: 9719 patients were in the FLD group, and 3014 patients were in the ALD group. The primary outcome was revision ACLR with a non-inferiority margin for ALDs at 4% at the 2-year follow-up. The secondary outcomes were anterior and rotatory knee stability and PROMs based on the Knee Injury and Osteoarthritis Outcome Score (KOOS) at the 1-year follow-up. RESULTS: The crude cumulative revision rates in ALD implants at 2 and 5 years were 2.1% (95% CI 1.62-2.68) and 5.0% (95% CI 4.22-5.96), respectively. In the FLD group, the rates were 2.2% (95% CI 1.89-2.48) at 2 years and 4.7% (95% CI 4.31-5.20) at 5 years. The 1-year side-to-side differences were 0.97 mm (95% CI 0.90-1.03) in the ALD group and 1.45 mm (95% CI 1.41-1.49) in the FLD group. In the FLD group, 13% had a positive pivot shift, and in the ALD group, 6% had a positive pivot shift. There were no differences in KOOS. CONCLUSION: ALDs were non-inferior to FLDs regarding revision rates, knee stability, and patient-reported outcomes. Based on this conclusion, ALDs are safe to use for femoral fixation in ACLR. LEVEL OF EVIDENCE: III.


Subject(s)
Anterior Cruciate Ligament Reconstruction , Humans , Cohort Studies , Knee Joint/surgery , Reoperation , Knee/surgery
15.
Knee Surg Sports Traumatol Arthrosc ; 31(5): 1658-1664, 2023 May.
Article in English | MEDLINE | ID: mdl-34477895

ABSTRACT

PURPOSE: Persistent deficits in knee flexor strength following harvest of semitendinosus and gracilis for anterior cruciate ligament reconstruction are inconsistent in the literature. Variation in methodology, including measuring torque at higher knee flexion angles may partially explain these discrepant findings. The objective of this study was to determine whether positioning (seated vs supine), consideration of peak or joint-angle-specific torque or device (Isokinetic Dynamometer vs NordBord Hamstring Dynamometer) impact the magnitude of knee flexor strength differences between limbs. METHODS: Participants (n = 31, 44.2 ± 10.7 years,) who were at 14 ± 4.4 years follow-up for unilateral ACL reconstruction with semitendinosus/gracilis grafts completed the ACL Quality of Life outcome and an assessment including isokinetic concentric knee extensor and flexor strength in seated and supine with peak torque and torque at 60° (T60) and 75° (T75) knee flexion measured, followed by an eccentric Nordic Hamstring Curl. RESULTS: Isokinetic concentric knee flexor torque was reduced in supine relative to seated, on the reconstructed limb against the unaffected, and at higher degrees of knee flexion relative to peak torque (T60 and T75 against peak torque). Limb symmetry varied by methodology (F(6,204) = 8.506, p = 0.001) with reduced symmetry in supine T75 against all measures (71.1 ± 16.5%, p < 0.05), supine T60 against seated peak torque (82.7 ± 14.2%, p < 0.05), and the NordBord was lower than seated peak torque that was not statistically significant (83.9 ± 12.8%, n.s.). Knee extensor peak (r2 = 0.167 (F(1,27) = 5.3, p = 0.03) and Nordic curl eccentric torque (r2 = 0.267, F(2,26) = 4.736, p = 0.02) were predictors of ACL-QoL score, although a combined model did not improve over Nordic torque alone. CONCLUSION: Limb symmetry cannot be assumed in clinical practice across differing assessment methods for knee flexor strength as deficits are greatest in the supine position with torque measured at 75° knee flexion. Isokinetic knee extensor and eccentric knee flexor torque during the Nordic hamstring curl were predictors of ACL-QoL scoring and should be considered alongside patient-reported outcomes for patients following ACL reconstruction with hamstring grafts. LEVEL OF EVIDENCE: Level IV.


Subject(s)
Hamstring Muscles , Quality of Life , Humans , Follow-Up Studies , Knee Joint/surgery , Knee
16.
Knee Surg Sports Traumatol Arthrosc ; 31(7): 2784-2793, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36378292

ABSTRACT

PURPOSE: To compare the midterm clinical outcomes of different meniscal surgeries in patients undergoing anatomic double-bundle anterior cruciate ligament reconstruction (DB-ACLR) with eight strands of hamstring (HT8) autografts and explore the potential predictive risk factors for residual knee laxity. METHODS: From 2010 to 2017, a total of 410 patients who underwent anatomic trans-tibial DB-ACLR with HT8 autografts (169 patients without meniscal surgery, 105 patients with meniscal repair, and 136 patients with meniscal resection) were included in this study. The equivalent graft diameter was introduced to make the total graft size of DB-ACLR comparable with that of single-bundle ACLR and calculated as the square root of the quadratic sum of the diameter for each bundle. Residual laxity was defined as excessive anterior tibial translation or residual pivot shift at any follow-up visit, while graft rupture was confirmed by second-look arthroscopy or magnetic resonance imaging. RESULTS: The mean follow-up period was 8.3 ± 2.2 years. The mean equivalent graft diameter was 9.9 ± 0.7 mm. Graft rupture was confirmed in 16 (3.9%) patients, while residual laxity was detected in 72 (17.6%) patients (34 [25.0%] in the meniscal resection group vs. 22 [13.0%] in the no meniscal surgery group, p = 0.021). In the multivariate logistic regression analysis, high-grade preoperative knee laxity (odds ratio OR 2.04, p = 0.020), equivalent graft diameter < 9 mm (OR 3.31 compared with 9-10 mm, p = 0.012; OR 3.28 compared with ≥ 10 mm, p = 0.019), and meniscal resection (OR 1.94 compared with no meniscal surgery, p = 0.045) were associated with residual laxity. CONCLUSION: During a midterm follow-up, meniscal resection increased the risk of residual knee laxity even in patients undergoing anatomic DB-ACLR with HT8 autografts. Increasing the hamstring graft diameter and preserving the menisci are important strategies for ACLR to restore knee stability. LEVEL OF EVIDENCE: Level III.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament Reconstruction , Hamstring Tendons , Humans , Autografts/surgery , Meniscectomy , Hamstring Tendons/transplantation , Knee Joint/surgery , Anterior Cruciate Ligament Reconstruction/methods , Anterior Cruciate Ligament Injuries/surgery
17.
J Med Life ; 16(10): 1445-1447, 2023 Oct.
Article in English | MEDLINE | ID: mdl-38313178

ABSTRACT

The goal of the current investigation was to measure the size of the anterior cruciate ligament (ACL) graft following hamstring (gracilis and semitendinosus) tendon autograft procedures in a relatively large sample size of Iraqi men. In this study, the quadruple hamstring tendon (semitendinosus and gracilis) was measured in a sample of Iraqi adult males. The study enrolled 300 Iraqi men who underwent anterior cruciate ligament repair at Diwaniyah Teaching Hospital and Alforat Alawast Private Hospital between January 2020 and December 2021. The repair procedure was based on the utilization of the quadruple (gracilis and semitendinosus) hamstring tendon. The primary outcome measure was the size of the tendon, determined using a sizing tube calibrated to 0.5 mm. Out of the sample, 80% of patients had a graft diameter of 7.5 mm, while 15% had a graft diameter of 8 mm, and 5% had a diameter of 7 mm. Body mass index was a poor predictor of graft size, whereas patient height was an excellent predictor of graft diameter. The graft diameter in most Iraqi subjects with anterior cruciate ligament injuries needs to be five bands or even six bands; otherwise, other graft sources like bone-patellar-bone or peroneus longus tendon grafts should be considered. The graft diameter may be reliably anticipated based on the patient's height.


Subject(s)
Anterior Cruciate Ligament Injuries , Hamstring Muscles , Adult , Male , Humans , Anterior Cruciate Ligament , Hamstring Muscles/surgery , Iraq , Anterior Cruciate Ligament Injuries/surgery , Tendons/transplantation
18.
BMC Musculoskelet Disord ; 23(1): 1096, 2022 Dec 14.
Article in English | MEDLINE | ID: mdl-36517815

ABSTRACT

BACKGROUND: Previous studies have compared different kinds of fixations for anterior cruciate ligament reconstruction. Nevertheless, there is no optimal method to date. To the best of authors' knowledge, there is no article discussing the combination of adjustable suspensory device and interference screw for hybrid tibial fixation. METHODS: In total, 66 patients (n = 34, adjustable suspensory device and interference screw; n = 32, cortical screw and interference screw) were analyzed. Their International Knee Documentation Committee score and Tegner activity level scale were evaluated before and after a 2-year follow-up. The Single Assessment Numeric Evaluation score was evaluated after a 2-year follow-up. Physical exams such as range of motion, anterior knee pain (VAS > = 3) and Lachman test were assessed before and at least 12 months after surgery. To evaluate tunnel widening, anteroposterior and lateral view radiography was conducted 1 day and at least 12 months after surgery. A more than 10% change was considered tibial tunnel widening. Mann-Whitney U test, independent t test, paired t test, Fisher's exact test and chi-squared test were used to compare the variables. Linear and logistic regression models were applied to adjust for potential confounders. RESULTS: No variable except gender (P = 0.006) showed significant difference with regard to demographic data. After adjustment, there was no statistically significant difference between the groups regarding post-operative physical exams. Patients who used adjustable suspensory device and interference screw had lower post-operative Single Assessment Numeric Evaluation score (adjusted ß - 8.194; P = 0.017), Tegner activity level scale (adjusted ß - 1.295; P = 0.001) and pre-operative degrees of knee flexion (adjusted ß - 2.825; P = 0.026). Less percentage of tunnel widening in the lateral view of radiographs was seen in patients in group of adjustable suspensory device and interference screw (adjusted ß - 1.733; P = 0.038). No significant difference was observed in the anteroposterior view of radiographs (adjusted ß - 0.667; P = 0.26). CONCLUSION: In these 66 patients, we observed less tibial tunnel widening and lower post-operative functional scores in the group of adjustable suspensory device and interference screw. Both groups displayed similar outcomes of physical exams as well as improvement after operation. The proposed method may become an alternative option. Nonetheless, the quality of our study is still limited, and thus further studies are warranted to determine the efficacy and further application. TRIAL REGISTRATION: Joint Institutional Review Board of Taipei Medical University, Taipei, Taiwan (No: N201805094 ). STUDY DESIGN: Prospective comparative cohort study; Level of evidence, II.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament Reconstruction , Humans , Prospective Studies , Cohort Studies , Femur/surgery , Anterior Cruciate Ligament Reconstruction/methods , Tibia/diagnostic imaging , Tibia/surgery , Knee Joint/surgery , Anterior Cruciate Ligament Injuries/diagnostic imaging , Anterior Cruciate Ligament Injuries/surgery
19.
Cureus ; 14(10): e30138, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36381718

ABSTRACT

INTRODUCTION: The present study was done to analyze the functional outcome, donor site morbidities, and associated parameters when using the anterior half of the peroneus longus for augmentation of an inadequate hamstring graft when performing arthroscopic anterior cruciate ligament (ACL) reconstruction. METHODS: Thirty patients with complete ACL tears were operated on. In all these patients, the thickness or length of the hamstring graft taken was found to be inadequate (less than 8 mm and 7.5 cm, respectively). So, additionally, the anterior half of the peroneus longus tendon (AHPLT) graft was harvested to reach an optimum size of the final graft. Functional outcome was assessed using the International Knee Documentation Committee (IKDC) score at six weeks, three months, and six months. The Foot and Ankle Disability Index (FADI) score at six months was used to assess ankle stability. RESULTS: The mean age in our study was 28.8 years with male predominance (73.33%). The mean operative time was 86.4 minutes. The mean hamstring graft thickness in our study was 6.5 mm, which improved to 9.12 mm after augmentation. The mean graft length after AHPLT augmentation was 9.38 cm. The mean IKDC score at six months was 87.35. At the end of six months, FADI scores were found within normal limits (range: 135-136) in all the patients. No complications were noted in any of the patients. CONCLUSION: The AHPLT graft was always found to be sufficient enough for augmenting the hamstring graft to reach an acceptable thickness and length. There was no graft site morbidity and the ankle functional levels remained the same as preoperative levels, making it an excellent choice for augmentation of inadequate hamstring grafts.

20.
Knee ; 38: 193-200, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36095927

ABSTRACT

BACKGROUND: To determine the ideal fixation technique for an ACL reconstruction with a hamstring graft, multiple studies have been undertaken to define the initial biomechanical properties of tibial fixation. PURPOSE: The aim of this study was to compare the biomechanical properties of tibial fixation methods by creating single or hybrid systems. METHODS: Bovine tibias and forefoot digital extensor tendons were prepared with four different tibial anterior cruciate ligament fixation methods and compared biomechanically. Fixation materials included polyethylene Ultrabraid high-strength sutures, Biosure interference screws (Smith and Nephew, Memphis, TN, USA), staples (Smith and Nephew, Richards Regular Fixation Staples without Spikes, Memphis, TN, USA), and knotless suture anchors (Multifix-S PEEK) (Smith and Nephew, Memphis, TN, USA). Four groups (n = 5 specimens) were established - group I: single fixation with interference screws; group II: single fixation with knotless anchors; group III: hybrid fixation with interference screws and staples; group IV: hybrid fixation with interference screws and knotless anchors. Each specimen underwent evaluations for cyclic displacement, cyclic stiffness, initial loading strength, ultimate failure load, pull-out displacement, and pull-out stiffness. RESULTS: All specimens completed cyclic loading and load-to-failure. The cyclic displacement in group II, which had a single fixation, indicated significantly greater elongation compared with the other groups (P = 0.002). The hybrid systems were more rigid than the single systems in terms of cyclic stiffness, and no statistically significant difference was observed between the hybrid systems (P = 0.461). Group IV was significantly superior in terms of the ultimate failure load (P = 0.004). No statistically significant differences were noted between the groups for pull-out displacement or pull-out stiffness. CONCLUSION: Single fixation with bioscrews as an in-tunnel tibia fixation method was as successful as hybrid systems. Multifix-S PEEK knotless suture anchors, which can be combined with bioscrews, can be a superior fixation alternative due to its flexibility and ultimate failure load values.


Subject(s)
Bone Screws , Tibia , Animals , Benzophenones , Biomechanical Phenomena , Cattle , Humans , Polyethylenes , Polymers , Tibia/surgery
SELECTION OF CITATIONS
SEARCH DETAIL