Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
Add more filters











Publication year range
1.
J Fluoresc ; 2024 Mar 08.
Article in English | MEDLINE | ID: mdl-38457074

ABSTRACT

This study emphasis the solvent effect on third-order nonlinear optical (NLO) features of methyl red (MR) dye dissolved in polar solvents including ethanol, methanol, acetone, 1-propanol, DMF and DMSO using low power diode laser. Z-scan technique operating at 405 nm wavelength, is used to estimate the third-order NLO features of MR dye in various solvents. The dye discloses self-defocusing nonlinear index of refraction (n2), which is determined to be the order of 10-7 cm2/W. The nonlinear coefficient of absorption (ß) of MR dye displays both negative and positive value owing to saturable absorption (SA) and reverse saturable absorption (RSA), respectively. The real and imaginary components of the third-order NLO susceptibility of MR dye in polar solvents are measured to be the order of 10-6 esu and 10-7 esu, respectively. The dye exhibits a large NLO susceptibility in DMSO, which is estimated to be 1.21 × 10-6 esu. The effect of solvent spectral features on MR dye is determined by applying a multi-parameter scale called Kamlet-Abboud-Taft. The experiment results indicate that MR dye is a promising NLO material that may find applications in photonics and optoelectronics.

2.
J Fluoresc ; 33(6): 2295-2304, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37036629

ABSTRACT

In this work, we report on the fabrication, characterization and the third-order nonlinear optical (NLO) properties of basic blue 7 (BB 7) dye‒doped polyvinyl alcohol (PVA) polymer thin films. The absorption spectra of BB 7 dye‒PVA films were measured by UV‒visible absorption studies. The functional groups of BB 7‒PVA films have been identified by FT‒IR spectroscopic analysis. The surface morphology was examined by AFM and SEM analysis which shows that the BB 7 dye‒doped PVA films have a homogenous and smooth surface. The nonlinear absorption and refraction of BB 7‒PVA films were respectively explored by open aperture and closed aperture Z‒scan technique using a 5 mW semiconductor diode laser of 635 nm wavelengths. The BB 7‒PVA films exhibit the reverse saturable absorption (RSA) and self-defocusing effect and the measured third‒order nonlinear susceptibility χ(3) values of these films were found to be of the order of 10- 5 esu. The present experimental results show that BB 7‒PVA films may have potential applications in future photonic and NLO devices.

3.
Photodiagnosis Photodyn Ther ; 42: 103307, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36709016

ABSTRACT

INTRODUCTION: Medical workers commonly physically identify subcutaneous veins to locate a suitable vesselto implant a catheter for drug administration or blood sample. The general rule of thumb is to locate a big, clean vein that will allow the medication to readily pass within the intended blood vessel. Peripheral problematic venous access happens when a patient's veins are difficult to palpate because of factors like dark skin tone, edema or excess tissue. The ability to see how the vasculature changes to support the therapeutic methods without damaging the surrounding tissue is another challenge. MATERIALS AND METHODS: Hyperspectral imaging (HI) is a developing technique with several potential uses in medicine. Using its spectroscopic data, veins and arterioles could be noninvasively detected and discriminated. It is frequently important to use quantitative phase analysis for vein localization. To assess hyperspectral image data for the detection of both veins and peripheral arteries, we suggest using an advanced image processing and classification algorithm based on the phase information related to the index of refraction change and associated scattering. We show that this need may be satisfied using quantitative phase imaging of forearm skin tissue at different depths. RESULTS: To demonstrate the variations in the diffuse reflectance characteristics between skin surface and veins, phase resolved pictures were successfully produced for twelve volunteers using our imaging methodology. We found that the skin surface details are completely apparent at the unique wavelength of 441 nm. The 500-nm wavelength was the most efficient for grouping peripheral arteries and illuminating the blood perfusion maps. Using our HI experimental setup and our phase imaging procedure on the 600 nm and 650 nm visible spectral pictures, we were able to properly describe the vein map. This spectral area may be utilized as a vein locator marker which could approximately reach till 3 mm depth under skin surface. CONCLUSIONS: Initial findings suggested that our imaging technique would be able to assist medical examiners in safely assessing the veins and arteriole's locations automatically without exposing the skin to infrared radiation. Meanwhile, our pilot research in this work to determine the best spectral wavelengths for localizing veins and mapping blood perfusion using our phase analysis imaging strategy with the HI camera. By substituting the HI camera with a custom conventional RGB camera that only functions at specific wavelengths during the discovering of blood perfusion locations or prior to intravenous catheterization, a distinctive and efficient system for precise identification may be developed to serve in the field of the vascular therapeutic methods.


Subject(s)
Hyperspectral Imaging , Photochemotherapy , Humans , Photochemotherapy/methods , Photosensitizing Agents , Veins/diagnostic imaging , Perfusion
4.
Materials (Basel) ; 14(23)2021 Nov 30.
Article in English | MEDLINE | ID: mdl-34885522

ABSTRACT

Gallium nitride (GaN) doped with germanium at a level of 1020 cm-3 is proposed as a viable material for cladding layers in blue- and green-emitting laser diodes. Spectral reflectometry and ellipsometry are used to provide evidence of a reduced index of refraction in such layers. The refractive-index contrast to undoped GaN is about 0.990, which is comparable to undoped aluminium gallium nitride (AlGaN) with an aluminium composition of 6%. Germanium-doped GaN layers are lattice-matched to native GaN substrates; therefore, they introduce no strain, cracks, and wafer bowing. Their use, in place of strained AlGaN layers, will enable significant improvements to the production process yield.

5.
Biotechnol Prog ; 37(5): e3187, 2021 09.
Article in English | MEDLINE | ID: mdl-34164947

ABSTRACT

Protein concentration determination is a necessary in-process control for the downstream operations within biomanufacturing. As production transitions from batch mode to an integrated continuous bioprocess paradigm, there is a growing need to move protein concentration quantitation from off-line to in-line analysis. One solution to fulfill this process analytical technology need is an in-line index of refraction (IoR) sensor to measure protein concentration in real time. Here the performance of an IoR sensor is evaluated through a series of experiments to assess linear response, buffer matrix effects, dynamic range, sensor-to-sensor variability, and the limits of detection and quantitation. The performance of the sensor was also tested in two bioprocessing scenarios, ultrafiltration and capture chromatography. The implementation of this in-line IoR sensor for real-time protein concentration analysis and monitoring has the potential to improve continuous bioprocess manufacturing.


Subject(s)
Antibodies, Monoclonal/analysis , Bioreactors , Recombinant Proteins/analysis , Refractometry/methods , Animals , CHO Cells , Chromatography , Cricetinae , Cricetulus , Humans , Ultrafiltration
6.
Appl Spectrosc ; 74(8): 851-867, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32383392

ABSTRACT

In combination with other parameters, the real, n(v∼), and imaginary, k(v∼), components of the complex refractive index, n^ = n + ik, can be used to simulate the optical properties of a material in different forms, e.g., its infrared spectra. Ultimately, such n/k values can be used to generate a database of synthetic reflectance spectra for the different morphologies to which experimental data can be compared. But obtaining reliable values of the optical constants n/k for solid materials is challenging due to the lack of optical quality specimens, usually crystals, large enough to measure. An alternative to crystals is to press the powder into a uniform disk. We have produced pellets from ammonium sulfate, (NH4)2SO4, powder and derived the pellets' n and k values via single-angle reflectance using a specular reflectance device in combination with a Fourier transform infrared spectrometer. The single-angle technique measures amplitude of light reflected from the material as a function of wavelength over a wide spectral domain; the optical constants are determined from the reflectance data using the Kramers-Kronig relationship. We investigate several parameters associated with the pellets and pellet formation and their effects upon delivering the most reliable n/k values. Parameters studied include pellet diameter, mass, and density (void space), drying, grinding, sieving, and particle size in the pellet formation, as well as pressing pressure and duration. Of these parameters, using size-selected mixtures of dried, small (<50 µm) particles and pressing at ≥10 tons for at least 30 min were found key to forming highly reflective samples. Comparison of two sets of previous literature n(v∼) and k(v∼) values obtained from crystalline (NH4)2SO4 both as crystal reflectance as well as extinction spectra of aerosols measured in a flow tube shows reasonable agreement, but suggests the present values, as confirmed from two independent techniques, represent a substantial improvement for n/k values for (NH4)2SO4, also demonstrating promise to measure the optical constants of other materials.

7.
Chemphyschem ; 21(8): 707-711, 2020 04 20.
Article in English | MEDLINE | ID: mdl-32074389

ABSTRACT

Beer's empiric law states that absorbance is linearly proportional to the concentration. Based on electromagnetic theory, an approximately linear dependence can only be confirmed for comparably weak oscillators. For stronger oscillators the proportionality constant, the molar attenuation coefficient, is modulated by the inverse index of refraction, which is itself a function of concentration. For comparably weak oscillators, the index of refraction function depends, like absorbance, linearly on concentration. For stronger oscillators, this linearity is lost, except at wavenumbers considerably lower than the oscillator position. In these transparency regions, linearity between the change of the index of refraction and concentration is preserved to a high degree. This can be shown with help of the Kramers-Kronig relations which connect the integrated absorbance to the index of refraction change at lower wavenumbers than the corresponding band. This finding builds the foundation not only for refractive index sensing, but also for new interferometric approaches in IR spectroscopy, which allow measuring the complex index of refraction function.

8.
J Quant Spectrosc Radiat Transf ; 234: 32-39, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31631911

ABSTRACT

Accurate Rayleigh scattering cross sections are important for understanding the propagation of electromagnetic radiation in planetary atmospheres and for calibrating mirror reflectivity in high finesse optical cavities. In this study, we used Broadband Cavity Enhanced Spectroscopy (BBCES) to measure Rayleigh scattering cross sections for argon, carbon dioxide, sulfur hexafluoride, and methane between 333 and 363 nm, extending the region of available UV measurements for all four gases. Comparison of our results with refractive index based (n-based) calculations demonstrates excellent agreement for Ar and CO2, within 0.2% and 1.0% on average, respectively. For SF6, our mean Rayleigh scattering cross sections are lower by 2.2% on average relative to the n-based calculation and lie outside the 1-σ measurement uncertainty; however, the results still fall within our 2-σ uncertainty. The measured Rayleigh scattering cross sections for CH4 are in substantial disagreement (22%) with those calculated from the most recent n-based values in the literature and lie far outside our mean 1-σ uncertainty of 1.6%. Extrapolation of several older index of refraction measurements from visible wavelengths to the UV yields better agreement with our results for CH4, but the agreement is still generally outside our 1-σ measurement uncertainty. Use of the dispersion relation derived in this work provides significantly improved Rayleigh scattering cross sections for CH4 in the UV-A spectral region.

9.
Microsc Microanal ; 23(5): 978-988, 2017 10.
Article in English | MEDLINE | ID: mdl-28918767

ABSTRACT

The refractive index in the interior of single cells affects the evanescent field depth in quantitative studies using total internal reflection (TIR) fluorescence, but often that index is not well known. We here present method to measure and spatially map the absolute index of refraction in a microscopic sample, by imaging a collimated light beam reflected from the substrate/buffer/cell interference at variable angles of incidence. Above the TIR critical angle (which is a strong function of refractive index), the reflection is 100%, but in the immediate sub-critical angle zone, the reflection intensity is a very strong ascending function of incidence angle. By analyzing the angular position of that edge at each location in the field of view, the local refractive index can be estimated. In addition, by analyzing the steepness of the edge, the distance-to-substrate can be determined. We apply the technique to liquid calibration samples, silica beads, cultured Chinese hamster ovary cells, and primary culture chromaffin cells. The optical technique suffers from decremented lateral resolution, scattering, and interference artifacts. However, it still provides reasonable results for both refractive index (~1.38) and for distance-to-substrate (~150 nm) for the cells, as well as a lateral resolution to about 1 µm.


Subject(s)
Microscopy, Interference/methods , Physical Phenomena , Refractometry/methods , Animals , CHO Cells , Cell Line , Chromaffin Cells , Cricetulus , Microscopy, Fluorescence/methods
10.
Electromagn Biol Med ; 36(1): 55-62, 2017.
Article in English | MEDLINE | ID: mdl-27368079

ABSTRACT

Heretofore only observed in living systems, we report that weak-field ion cyclotron resonance (ICR) also occurs in inanimate matter. Weak magnetic field (50 nT) hydronium ICR at the field combination (7.84 Hz, 7.5 µT) markedly changes water structure, as evidenced by finding an altered index of refraction exactly at this combined field. This observation utilizes a novel technique which measures the scattering of a He-Ne laser beam as the sample is exposed to a ramped magnetic field frequency. In addition to the hydronium resonance, we find evidence of ICR coupling to a more massive structure, possibly a tetrahedral combination of three waters and a single hydronium ion. To check our observations, we extended this technique to D2O, successfully predicting the specific ICR charge-to-mass ratio for D3O+ that alters the index of refraction.


Subject(s)
Cyclotrons , Onium Compounds/chemistry , Refractometry/instrumentation , Water/chemistry , Deuterium Oxide/chemistry , Magnetic Fields , Vibration
11.
Appl Spectrosc ; 71(5): 1039-1049, 2017 May.
Article in English | MEDLINE | ID: mdl-27645725

ABSTRACT

Three refractive index mixing rules, Arago-Biot, Lorentz-Lorenz, and Newton, are generalized to complex refractive index and used to define infrared (IR) spectra of the corresponding ideal liquid mixtures. Using the measured optical constants n and k for acetonitrile-water mixtures (Bertie and Lan, 1997) the excess absorbances, AE = Aobs - Aideal, are calculated. Relying upon the well-established properties of the acetonitrile-water mixtures, the interpretation of the excess absorbances is established that is essentially based on the understanding of a liquid as a set of oscillators. The set depends on the composition of the mixture and comprises oscillators as present in the pure components and oscillators perturbed by hydrogen bonding between unlike molecules. The main features of an excess spectrum can be established assuming chemical equilibria among various oscillators. The most informative parts of the spectrum of a yet unstudied binary system can well be observed and even qualitatively explained from the excess absorbance provided: first, a detailed vibrational study of the components has been done; and, second, it is well understood what actually is subtracted from Aobs. As examples, the binary mixtures of ethynylbenzene and tetrachloroethylene and 2-ethynylpyridine and tetrachloroethylene are considered.

12.
Molecules ; 21(12)2016 Dec 16.
Article in English | MEDLINE | ID: mdl-27999294

ABSTRACT

A hyperspectral reflectance confocal microscope (HSCM) was realized by CNR-ISC (Consiglio Nazionale delle Ricerche-Istituto dei Sistemi Complessi) a few years ago. The instrument and data have been already presented and discussed. The main activity of this HSCM has been within biology, and reflectance data have shown good matching between spectral signatures and the nature or evolution on many types of cells. Such a relationship has been demonstrated mainly with statistical tools like Principal Component Analysis (PCA), or similar concepts, which represent a very common approach for hyperspectral imaging. However, the point is that reflectance data contains much more useful information and, moreover, there is an obvious interest to go from reflectance, bound to the single experiment, to reflectivity, or other physical quantities, related to the sample alone. To accomplish this aim, we can follow well-established analyses and methods used in reflectance spectroscopy. Therefore, we show methods of calculations for index of refraction n, extinction coefficient k and local thicknesses of frequency starting from phase images by fast Kramers-Kronig (KK) algorithms and the Abeles matrix formalism. Details, limitations and problems of the presented calculations as well as alternative procedures are given for an example of HSCM images of red blood cells (RBC).


Subject(s)
Microscopy, Confocal/methods , Spectrophotometry/methods , Algorithms , Birefringence , Erythrocytes/ultrastructure , Humans
13.
Phys Med ; 32(12): 1785-1789, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27793538

ABSTRACT

We report results of the computed tomography reconstruction of the index of refraction in a whole rabbit knee joint examined at the photon energy of 51keV. Refraction based images make it possible to delineate the bone, cartilage, and soft tissues without adjusting the contrast window width and level. Density variations, which are related to tissue composition and are not visible in absorption X-ray images, are detected in the obtained refraction based images. We discuss why refraction-based images provide better detectability of low contrast features than absorption images.


Subject(s)
Knee Joint/diagnostic imaging , Tomography, X-Ray Computed/methods , Animals , Feasibility Studies , Image Processing, Computer-Assisted , Osteoarthritis, Knee/diagnostic imaging , Rabbits
14.
Inhal Toxicol ; 28(12): 537-545, 2016 10.
Article in English | MEDLINE | ID: mdl-27644268

ABSTRACT

CONTEXT: Knowledge of the droplet size distribution of inhalable aerosols is important to predict aerosol deposition yield at various respiratory tract locations in human. Optical methodologies are usually preferred over the multi-stage cascade impactor for high-throughput measurements of aerosol particle/droplet size distributions. OBJECTIVE: Evaluate the Laser Aerosol Spectrometer technology based on Polystyrene Sphere Latex (PSL) calibration curve applied for the experimental determination of droplet size distributions in the diameter range typical of commercial e-cigarette aerosols (147-1361 nm). MATERIALS AND METHODS: This calibration procedure was tested for a TSI Laser Aerosol Spectrometer (LAS) operating at a wavelength of 633 nm and assessed against model di-ethyl-hexyl-sebacat (DEHS) droplets and e-cigarette aerosols. The PSL size response was measured, and intra- and between-day standard deviations calculated. RESULTS: DEHS droplet sizes were underestimated by 15-20% by the LAS when the PSL calibration curve was used; however, the intra- and between-day relative standard deviations were < 3%. This bias is attributed to the fact that the index of refraction of PSL calibrated particles is different in comparison to test aerosols. This 15-20% does not include the droplet evaporation component, which may reduce droplet size prior a measurement is performed. Aerosol concentration was measured accurately with a maximum uncertainty of 20%. Count median diameters and mass median aerodynamic diameters of selected e-cigarette aerosols ranged from 130-191 nm to 225-293 nm, respectively, similar to published values. DISCUSSION AND CONCLUSION: The LAS instrument can be used to measure e-cigarette aerosol droplet size distributions with a bias underestimating the expected value by 15-20% when using a precise PSL calibration curve. Controlled variability of DEHS size measurements can be achieved with the LAS system; however, this method can only be applied to test aerosols having a refractive index close to that of PSL particles used for calibration.


Subject(s)
Aerosols/analysis , Electronic Nicotine Delivery Systems , Spectrum Analysis/methods , Calibration , Particle Size , Polystyrenes/analysis
15.
J Chem Sci (Bangalore) ; 124(1): 281-289, 2012 Jan 01.
Article in English | MEDLINE | ID: mdl-24098068

ABSTRACT

Two-photon microscopy depends extensively on the two-photon absorption cross-sections of biologically relevant chromophores. High repetition rate (HRR) lasers are essential in multiphoton microscopy for generating satisfactory signal to noise at low average powers. However, HRR lasers generate thermal distortions in samples even with the slightest single photon absorption. We use an optical chopper with HRR lasers to intermittently 'blank' irradiation and effectively minimize thermal effects to result in a femtosecond z-scan setup that precisely measures the two-photon absorption (TPA) cross-sections of chromophores. Though several experimental factors impact such TPA measurements, a systematic effort to modulate and influence TPA characteristics is yet to evolve. Here, we present the effect of several control parameters on the TPA process that are independent of chromophore characteristics for femtosecond laser pulse based measurements; and demonstrate how the femtosecond laser pulse repetition rate, chromophore environment and incident laser polarization can become effective control parameters for such nonlinear optical properties.

16.
Cienc. tecnol. salud vis. ocul ; 7(2): 79-85, jul.-dic. 2009.
Article in Spanish | LILACS | ID: lil-560894

ABSTRACT

Para convertir las mediciones obtenidas de la superficie corneal a un valor dióptrico, el keratómetro de Bausch & Lomb Optical Company utiliza la fórmula (n’ – n)/ R y asume un índice n’ de 1,3375 (diferente al índice real de la córnea de 1,376). Este valor ficticio incluye una compensación para contrarrestar el pequeño pero significativo poder negativo de la superficie posterior de la córnea. Esto permite hacer la lectura directamente tanto del radio de curvatura como del poder dióptrico de la córnea.


To convert the measurements obtained from the corneal surface into dioptric value, the B&L keratometer uses the general lens formula (n’-n/R) and assumes an n’ of 1,3375 (compared to the actual corneal refractive index of n’=1,376). This is afictional value, which includes an allowance for the small, yet significant, negative power of the posterior corneal surface.


Subject(s)
Cornea , Refractometry
17.
J Res Natl Bur Stand (1977) ; 90(1): 3-26, 1985.
Article in English | MEDLINE | ID: mdl-34566140

ABSTRACT

The average diameter of the first micrometer particle size standard (Standard Reference Material 1690), an aqueous suspension of monosized polystyrene spheres with a nominal 1 µm diameter, was accurately determined by three independent techniques. In one technique the intensity of light scattered by a diluted suspension of polystyrene spheres was measured as a function of scattering angle, using a He-Ne laser polarized in the vertical direction. The second technique consisted of measuring as a function of angle the intensity of light scattered from individual polystyrene spheres suspended in air, using a He-Cd laser with light polarized parallel and perpendicular to the scattering plane. The measurement of row length by optical microscopy for polystyrene spheres arranged in close-packed, two-dimensional hexagonal arrays was the basis of the third technique. The measurement errors for each technique were quantitatively assessed. For the light scattering experiments, this required simulation with numerical experiments. The average diameter determined by each technique agreed within 0.5% with the most accurate value being 0.895±0.007 µm based on light scattering by an aqueous suspension. Transmission electron microscopy, flow through electrical sensing zone counter measurements, and optical microscopy were also used to obtain more detailed information on the size distribution including the standard deviation (0.0095 µm), fraction of off-size particles, and the fraction of agglomerated doublets (1.5%).

18.
J Res Natl Bur Stand (1977) ; 86(1): 27-32, 1981.
Article in English | MEDLINE | ID: mdl-34566037

ABSTRACT

The air density equation of Jones, Edlén's dispersion formula for standard air, and Edlén's empirically-derived expressions for the effects of Co2 abundance and water vapor partial pressure on refractivity have been combined into a simplified equation for the refractivity of air, and estimates have been made of uncertainties in calculated refractivity. Under ambient conditions typical of metrology laboratories, the agreement between the simplified equation and Edlén's formulation is well within the uncertainty in each. The simplified equation is valid in the visible region.

19.
Article in English | MEDLINE | ID: mdl-32196266

ABSTRACT

The index of refraction and absorptive properties are estimated in nuclear matter consisting of protons and neutrons and in nuclear matter charge neutralized by electrons.

20.
J Res Natl Bur Stand A Phys Chem ; 72A(4): 425-433, 1968.
Article in English | MEDLINE | ID: mdl-31824104

ABSTRACT

Index-of-refraction versus time isotherms have been established for germania glass. Using the crossover technique with air-quenched samples and applying the two relaxation time model previously reported for borosilicate glass, it was found that the width of the spectrum of relaxation times for germania glass was temperature dependent. Upon analyzing this in terms of a distribution of activation energies, the results showed that, similarly to B2O3, activation energies smaller than the activation energy present in the Arrhenius region appear at low temperatures. Extensive viscosity measurements by the fiber elongation method were made from 1011 to 6 × 1014 poises. From this data a lower and more precise value of the activation energy (E η = 72.3 kcal/mol) was obtained in the annealing range.

SELECTION OF CITATIONS
SEARCH DETAIL