Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 417
Filter
1.
Arq. bras. oftalmol ; Arq. bras. oftalmol;88(2): e2023, 2025. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1574012

ABSTRACT

ABSTRACT Aging and face sagging have many causes, and various techniques are used for treatment, including noninvasive procedures, such as focused ultrasound, which uses the principle of collagen regeneration by coagulative necrosis of the dermis layers using radiofrequency, but this procedure has complications. We reported a case of a 54-year-old female patient who complained of poor visual acuity in her right eye three days after a focused ultrasound facial aesthetic procedure, with the best visual acuity of 20/60. Biomicroscopy of the right eye revealed an acute cataract with three points of fibrosis extending from the posterior to the anterior capsule. The patient underwent phacoemulsification surgery with visual rehabilitation and improved vision of 20/20. We hypothesized that the occurrence of acute cataract was related to the inappropriate use of focused ultrasound.

2.
Arq. bras. oftalmol ; Arq. bras. oftalmol;88(1): e2022, 2025. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1568854

ABSTRACT

ABSTRACT Purpose: This study investigated the relationship between blood pressure and intraocular pressure in treatmentnaive, non-glaucoma patients with different blood pressure statuses, focusing on the 24-h ocular volume and nocturnal blood pressure decline. Methods: Treatment-naive, non-glaucoma patients undergoing hypertension evaluation were enrolled as study participants. Simultaneous 24-h ambulatory blood pressure measurement and 24-h ocular volume recording with a contact lens sensor. We also compared ocular volume curve parameters between normotensive and hypertensive patients, as well as between those with and without nocturnal blood pressure decline. Results: A total of 21 patients, including 7 normotensive and 14 treatment-naive hypertensive individuals, were included in the study. of them, 11 were dippers and 10 were non-dippers. No significant difference in the 24-h ocular volume slope was observed between the hypertensive and normotensive patients (p=0.284). However, dippers had a significantly higher 24-h ocular volume slope (p=0.004) and nocturnal contact lens sensor output (p=0.041) than non-dippers. Conclusion: Nocturnal blood pressure decline, rather than the blood pressure level, is associated with the increased 24-h ocular volume slope and nocturnal ocular volume. Further studies are required to determine whether the acceleration of glaucoma progression in dippers is primarily due to low blood pressure, high intraocular pressure, or a combination of both.

3.
Clin Ophthalmol ; 18: 2741-2749, 2024.
Article in English | MEDLINE | ID: mdl-39372225

ABSTRACT

Purpose: To determine clinical and refractive results after the implantation of EyeCryl Phakic Toric intraocular lens in patients with stable keratoconus. Methods: The study included all patients diagnosed with keratoconus who underwent implantation of an EyeCryl Phakic Toric intraocular lens (Biotech Healthcare Holding; Ahmedabad, India) in at least one eye and had a follow-up of at least 12 months. Visual and refractive data were collected for all patients, along with corneal tomography measurements using Pentacam, and vault measurement using optical coherence tomography. This retrospective study was conducted at a high-volume private refractive surgery center in Medellín, Colombia. Results: A total of 83 eyes from 47 patients were included in the study. The majority (71.1%) were female, with a mean age of 31.2 ± 5.1 years. After 12 months of follow-up post-surgery, the spherical equivalent improved significantly from -8.19 ± 4.04 D to -0.06 ± 0.48 D (p < 0.001). Furthermore, 77% of eyes had a post-surgical spherical equivalent within ±0.50 D, while 92% had residual astigmatism ≤0.50 D. Twelve months after surgery, mean manifest astigmatism was -0.28 ± 0.27 D. Uncorrected visual acuity also showed improvement, from 1.11 ± 0.35 LogMAR to 0.14 ± 0.11 LogMAR. Moreover, 52.4% of eyes demonstrated an improvement of at least one line in best-corrected visual acuity. Notably, no intraoperative or postoperative complications were observed in the study population. Conclusion: The implantation of EyeCryl Phakic Toric intraocular lenses represents a highly effective and safe option for correcting refractive errors in patients with a history of keratoconus. Refractive accuracy is excellent, and a significant proportion of patients experienced an improvement in their best-corrected vision by at least one line.

4.
Genes (Basel) ; 15(9)2024 Aug 25.
Article in English | MEDLINE | ID: mdl-39336711

ABSTRACT

Traboulsi syndrome is a rare genetic disorder characterized by facial dysmorphism, lens subluxation, anterior segment anomalies, and spontaneous filtering blebs. The syndrome is due to mutations in the ASPH gene, which plays a crucial role in the development and maintenance of the lens. This case report describes the clinical and genetic findings in a Mexican male with Traboulsi syndrome, highlighting the identification of a novel ASPH variant. A 21-year-old male presented with trauma to the right eye while playing soccer. He had a history of lens subluxation and dysmorphic facial features. Ophthalmic examination revealed right eye lens subluxation into the anterior chamber (with signs of a previous episode of acute angle closure) and left eye posterior and inferior lens subluxation with sectorial iris atrophy. Genetic analysis identified a pathogenic ASPH variant (NM_004318.3:c.1892G>A, p.Trp631*) and a novel likely pathogenic variant (deletion of exons 20-21), confirming Traboulsi syndrome. This is the first instance of Traboulsi syndrome in the Mexican population. The absence of spontaneous filtering blebs in this patient supports previous reports of the wide phenotypic variability that could be related to the type of mutation. This novel ASPH variant expands the known genetic heterogeneity of Traboulsi syndrome.


Subject(s)
Genetic Association Studies , Humans , Male , Young Adult , Mutation , Eye Abnormalities/genetics , Eye Abnormalities/pathology , Phenotype , Anterior Eye Segment/abnormalities , Anterior Eye Segment/pathology , Lens, Crystalline/pathology
5.
Eur J Ophthalmol ; : 11206721241278395, 2024 Aug 22.
Article in English | MEDLINE | ID: mdl-39169780

ABSTRACT

PURPOSE: Compare refractive results between mechanical PRK (mPRK) and transepithelial PRK (tPRK) with WaveLight Allegretto EX500 excimer laser system (Alcon Laboratories, Fort Worth, TX, USA). SETTING: Department of Ophthalmology of the Federal University of Sao Paulo, Brazil. DESIGN: Prospective and randomized study. METHODS: In 151 eyes of 73 patients with astigmatism and myopia, both eyes had similar refraction before surgery, with a maximum of 15-µm difference in ablation who underwent mPRK in one eye and tPRK in the contralateral eye. The mean age of the patients in this study was 31.45 ± 6.97 years (range, 22 to 54 years). RESULTS: A comparison was made with all variables between the two groups, and we found that UDVA and SE were worse in the tPRK group at six months than in the mPRK group. In the mPRK group, there was a higher frequency in the +/- 0.50 range and a lower frequency in the +/- 1.50 range. In the tPRK group, however, there was a lower frequency in the +/- 0.50 range and a higher frequency in the +/- 1.50 range. Concerning gain or loss of lines of sight, there was no association between the two groups (chi-square test, p = 0.887). CONCLUSION: Both mPRK and tPRK appear to have similar safety. However, mPRK was associated with significantly better UDVA and SE six months post-operatively.

6.
BMC Ophthalmol ; 24(1): 269, 2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38918765

ABSTRACT

BACKGROUND: To evaluate the optical performance and safety of a new multifocal lens with a novel optical design featuring two additional foci (or intensifiers) in patients with cataract and presbyopia. METHODS: In this single-center, non-randomized prospective observational study, 31 patients underwent implantation of the new multifocal IOL between March 2020 and November 2021 at a tertiary clinical center in Buenos Aires and Ramos Mejia, Argentina. Postoperative examinations with emphasis on uncorrected and corrected visual acuity at distance and near and at two different intermediate distances (80 cm and 60 cm) were performed during the 3 postoperative months. RESULTS: Of the 31 patients who underwent implantation of the new IOL, 30 underwent bilateral surgery (61 eyes in total). At 3 months, all 61 eyes had an uncorrected distance visual acuity (UCDVA) of at least 0.15 logMAR; 57 eyes (93%) had an uncorrected distance visual acuity (UCDVA) of 0.1 logMAR and 27 eyes (44%) had an UCDVA of 0.0 logMAR. At 80 cm, 60 eyes (98%) had an uncorrected intermediate visual acuity (UCIVA) of at least 0.1 log MAR and 48 eyes (79%) had an UCIVA of 0.0 logMAR. CONCLUSION: The new multifocal IOL with a novel optical concept (5 foci) showed a wide range of visual acuity especially at intermediate and near distances in patients undergoing cataract surgery. Uncorrected visual acuity was excellent at all tested distances, monocularly and binocularly, spectacle independence and patient satisfaction were high.


Subject(s)
Multifocal Intraocular Lenses , Presbyopia , Prosthesis Design , Visual Acuity , Humans , Visual Acuity/physiology , Prospective Studies , Female , Male , Aged , Middle Aged , Presbyopia/physiopathology , Presbyopia/surgery , Refraction, Ocular/physiology , Lens Implantation, Intraocular , Pseudophakia/physiopathology , Phacoemulsification , Cataract/complications , Cataract/physiopathology , Lenses, Intraocular , Aged, 80 and over , Follow-Up Studies
7.
Differentiation ; 138: 100792, 2024.
Article in English | MEDLINE | ID: mdl-38935992

ABSTRACT

The role extracellular matrix (ECM) in multiple events of morphogenesis has been well described, little is known about its specific role in early eye development. One of the first morphogenic events in lens development is placodal thickening, which converts the presumptive lens ectoderm from cuboidal to pseudostratified epithelium. This process occurs in the anterior pre-placodal ectoderm when the optic vesicle approaches the cephalic ectoderm and is regulated by transcription factor Pax6 and secreted BMP4. Since cells and ECM have a dynamic relationship of interdependence and modulation, we hypothesized that the ECM evolves with cell shape changes during lens placode formation. This study investigates changes in optic ECM including both protein distribution deposition, extracellular gelatinase activity and gene expression patterns during early optic development using chicken and mouse models. In particular, the expression of Timp2, a metalloprotease inhibitor, corresponds with a decrease in gelatinase activity within the optic ECM. Furthermore, we demonstrate that optic ECM remodeling depends on BMP signaling in the placode. Together, our findings suggest that the lens placode plays an active role in remodeling the optic ECM during early eye development.


Subject(s)
Extracellular Matrix , Gene Expression Regulation, Developmental , Lens, Crystalline , PAX6 Transcription Factor , Animals , Extracellular Matrix/metabolism , Mice , Lens, Crystalline/metabolism , Lens, Crystalline/growth & development , Lens, Crystalline/cytology , PAX6 Transcription Factor/metabolism , PAX6 Transcription Factor/genetics , Eye Proteins/metabolism , Eye Proteins/genetics , Bone Morphogenetic Protein 4/metabolism , Bone Morphogenetic Protein 4/genetics , Chick Embryo , Homeodomain Proteins/metabolism , Homeodomain Proteins/genetics , Tissue Inhibitor of Metalloproteinase-2/metabolism , Tissue Inhibitor of Metalloproteinase-2/genetics , Paired Box Transcription Factors/metabolism , Paired Box Transcription Factors/genetics , Repressor Proteins/metabolism , Repressor Proteins/genetics , Signal Transduction , Chickens/genetics , Eye/metabolism , Eye/growth & development , Eye/embryology
8.
Curr Eye Res ; 49(10): 1068-1073, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38856046

ABSTRACT

PURPOSE: This study describes a prototype developed for aphakia without capsular support (AWCS) and its proof of concept. METHODS: This descriptive study used a 3D software to create and analyze virtual prototypes before manufacturing. A nylon-6/nylon-6.6 copolymer filament and a 3D printer were used for prototyping. A device implantation technique was developed using a 23-gauge hypodermic needle. Two opposing markings, 2 mm posterior to the limbus, were made to determine the location of the scleral punctures and the final position of the device. After adequate centralization and positioning of the device, its haptics were cut and cauterized to generate thermal modeling of the extremity and allow the thickening of the tips (flange), serving as an anchoring mechanism to the sclera. The efficacy and adequacy of the technique and device were then evaluated. RESULTS: Vitreous tissue extrusion was not observed during the sclerotomy. The device was well fixed to the sclera; however, adequate IOL stability and centralization still needed to be achieved. The surgeon evaluated the adequacy of all the other devices' characteristics. CONCLUSIONS: The development of a technology prototype for correcting AWCS was possible. Although the proposed prototype met most of the established concept guidelines, the stability of the IOL position remains challenging.


Subject(s)
Aphakia, Postcataract , Humans , Aphakia, Postcataract/surgery , Aphakia, Postcataract/physiopathology , Lens Capsule, Crystalline/surgery , Lenses, Intraocular , Sclerostomy , Lens Implantation, Intraocular/methods , Sclera/surgery , Aphakia/surgery , Printing, Three-Dimensional , Prosthesis Design , Visual Acuity/physiology
9.
Heliyon ; 10(9): e29441, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38694032

ABSTRACT

This work utilizes a Gabor Holographic Optical Scheme integrated with a microscope objective and a thin convex plane lens. This bi-telecentric lens system corrects spherical aberration from the objective, maintains consistent magnification across various reconstruction distances, and ensures a plane incidence on CMOS. Depending on the focal lengths of the objective and lens, the final image can be enlarged or reduced compared to the classic Gabor system, resulting in high-quality reconstructed phase images without spherical aberration. This setup was employed to capture phase distribution and intensity images of planktonic objects, such as copepods, achieving superior image quality.

10.
J Radiol Prot ; 44(2)2024 May 28.
Article in English | MEDLINE | ID: mdl-38722296

ABSTRACT

The purpose of this study is to evaluate the occupational doses (eye lens, extremities and whole body) in paediatric cardiac interventional and diagnostic catheterization procedures performed in a paediatric reference hospital located in Recife, Pernambuco. For eye lens dosimetry, the results show that the left eye receives a higher dose than the right eye, and there is a small difference between the doses received during diagnostic (D) and therapeutic (T) procedures. The extrapolated annual values for the most exposed eye are close to the annual limit. For doses to the hands, it was observed that in a significant number of procedures (37 out of 45 therapeutic procedures, or 82%) at least one hand of the physician was exposed to the primary beam. During diagnostic procedures, the physician's hand was in the radiation field in 11 of the 17 catheterization procedures (65%). This resulted in a 10-fold increase in dose to the hands. The results underscore the need for optimization of radiation safety and continued efforts to engage staff in a radiation safety culture.


Subject(s)
Occupational Exposure , Radiation Dosage , Humans , Occupational Exposure/analysis , Child , Cardiac Catheterization , Radiation Protection , Lens, Crystalline/radiation effects , Radiography, Interventional , Radiation Exposure/analysis
11.
Nano Lett ; 24(21): 6362-6368, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38752764

ABSTRACT

Plasmonic nanoantennas have proven to be efficient transducers of electromagnetic to mechanical energy and vice versa. The sudden thermal expansion of these structures after an ultrafast optical pulsed excitation leads to the emission of hypersonic acoustic waves to the supporting substrate, which can be detected by another antenna that acts as a high-sensitivity mechanical probe due to the strong modulation of its optical response. Here, we propose and experimentally demonstrate a nanoscale acoustic lens comprised of 11 gold nanodisks whose collective oscillation at gigahertz frequencies gives rise to an interference pattern that results in a diffraction-limited surface acoustic beam of about 340 nm width, with an amplitude contrast of 60%. Via spatially decoupled pump-probe experiments, we were able to map the radiated acoustic energy in the proximity of the focal area, obtaining a very good agreement with the continuum elastic theory.

12.
Spectrochim Acta A Mol Biomol Spectrosc ; 317: 124409, 2024 Sep 05.
Article in English | MEDLINE | ID: mdl-38733912

ABSTRACT

Rhodamines constitute a class of dyes extensively investigated and applied in various contexts, primarily attributed to their high luminescence quantum yield. This study delves into the impact of aggregation on the thermal and optical properties of Rhodamine 6G (R-6G) solutions in distilled water. Examined properties encompass thermal diffusivity (D), temperature coefficient of the refractive index (dn/dT), fluorescence quantum efficiency (η), and energy transfer (ET). These parameters were assessed through thermal lens (TL) and conventional absorption and emission spectroscopic techniques. The dimerization of R-6G solutions was revisited, revealing that an increase in R-6G concentration alters the features of absorption and emission spectra due to dimer formation, resulting in unexpected behavior of η. Consequently, we introduce a novel model for the fraction of absorbed energy converted into heat (φ), which accounts for emissions from both monomers and dimers. Employing this model, we investigate and discuss the concentration-dependent behaviors of η for monomers (ηm) and dimers (ηd). Notably, our findings demonstrate that ηm values necessitate ηd = 0.2, a relatively substantial value that cannot be disregarded. Additionally, applying the Förster theory for dipole-dipole electric ET, we calculate microparameters for ET between monomers (CDD) and monomer-dimer (CDA). Critical ranges for ET in each case are quantified. Microparameter analysis indicates that ET between monomer-monomer and monomer-dimer species of R-6G dissolved in distilled water holds significance, particularly in determining ηm. These results bear significance, especially in scenarios involving high dye concentrations. While applicable to R-6G in water, similar assessments in other media featuring aggregates are encouraged.

13.
Eur J Ophthalmol ; : 11206721241245747, 2024 Apr 18.
Article in English | MEDLINE | ID: mdl-38632941

ABSTRACT

PURPOSE: To present a reproducible method to calculate the toricity needed at the intraocular lens (IOL) plane with toric phakic IOLs (ICL, Staar Surgical) and compare its results with those obtained with the online calculator provided by the manufacturer. DESIGN: Retrospective case series. SETTING: Private practice, Buenos Aires, Argentina. METHODS: The formula originally described by Holladay to calculate the IOL power in phakic eyes was used to calculate the required spherical power along the less refractive meridian and along the more refractive meridian. Meridional analysis was applied to calculate the required toricity at the IOL plane and the surgically induced corneal astigmatism was incorporated into the calculations. The refractive cylinder predicted by this method and by the online calculator of the manufacturer were compared to the postoperative refractive cylinder by means of vector analysis. The possible changes in the ratio of toricity in patients with different amounts of astigmatism and anterior chamber depth are assessed in a theoretical section. RESULTS: In 35 eyes, the measured mean postoperative refractive cylinder was 0.09 D @ 99°, the mean predicted postoperative refractive astigmatism was 0.04 D @ 102° according to the manufacturer's online calculator and 0.09 D @100° according to our method. With both methods, 91.43% of eyes had an absolute cylinder prediction error within ±0.50 diopters. CONCLUSIONS: The method described in this article to calculate the toricity of phakic IOLs has a refractive accuracy similar to that of the original calculator developed by the manufacturer.

14.
Cont Lens Anterior Eye ; 47(2): 102126, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38342733

ABSTRACT

OBJECTIVE: Despite the increasing prevalence of contact lens (CL) wear, knowledge and compliance with proper care remain suboptimal. This study aims to assess the level of knowledge and compliance with lens care practices in patients attending a third-level institution in Northeast Mexico. METHODS: A cross-sectional study using a self-administered online survey was conducted. Patients at the Instituto Tecnolgico de Monterrey were invited to participate. The questionnaire consisted of three sections: demographic data and CL information, CL practices, and CL care knowledge. Participants responding correctly to 6/7 questions from the second and third sections were classified as having good compliance and good knowledge, respectively. Predictive factors for good compliance and knowledge were calculated using a logistic regression model. RESULTS: A total of 287 users participated in the study. The median age was 25 (14-78) years with a female (n = 221, 77 %) predominance. Good knowledge was observed in 215 (74.9 %), whereas only 42 (14.6 %) presented good compliance. Failing to replace CL as prescribed (n = 199, 69.3 %) and sleeping with the devices (n = 198, 69 %) were the most frequent practices causing non-compliance. Whereas prohibition of swimming with CL was the least known practice (n = 74, 25 %). Users with recent (≤5 years) wearing experience were more likely to present good knowledge (OR 2.19, p = 0.014) and compliance (OR 3.15, p < 00.01). No statistical correlation was established between knowledge and compliance. CONCLUSION: Non-compliance and lack of knowledge of proper CL care were prevalent among in this population. Long-term CL users were at higher risk of non-compliance and lack of knowledge. Moreover, knowledge was not related to compliance; therefore, different strategies must be implemented to reduce CL misconduct.


Subject(s)
Contact Lenses, Hydrophilic , Contact Lenses , Humans , Female , Adult , Cross-Sectional Studies , Mexico/epidemiology , Contact Lens Solutions , Patient Compliance
15.
Appl Spectrosc ; 78(6): 644-649, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38378011

ABSTRACT

Thermal lens spectroscopy (TLS) is a high-sensitivity method to determine the concentration of light-absorbing species in samples. Here, we implemented a transient configuration of the technique, with a focused pump and a collimated probe beam coaxially propagating. A Fabry-Perot optical resonator is incorporated allowing multi-passing of the probe beam through the sample to enhance sensitivity. We show how the low detection limit of the method can be reduced approximately by half by making differential measurements of the signal at a far field in the center point of the probe beam spot and that obtained by spatial filtering of the same beam, the so-called eclipsed signal. Measurements were performed in test samples of Deyman's organic dye, Strawberry 2143 v.7, dissolved in ethanol. The thermal lens signal measured as a function of the dye concentration in water at the center of the beam was compared with the differential signal resulting from this and the eclipsed beam.

16.
Eur J Ophthalmol ; 34(5): 1458-1468, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38291620

ABSTRACT

PURPOSE: The main purpose of our study is to compare the adverse events occurrence, complications, and postoperative outcomes of Femtosecond Laser-Assisted Cataract Surgery (FLACS) versus conventional phacoemulsification surgery (CPS) in adult patients undergoing cataract surgery. METHODS: We conducted our research using PubMed, Scopus, and MEDLINE through EBSCOhost from 2012 to July 2022 with English and Spanish language restriction, including only Randomized Controlled Trials (RCTs). The PRISMA guidelines were observed for data abstraction, including a random-effects model for each outcome. RESULTS: We analyzed 4844 eyes from 23 RCTs with some low risk of bias according to RoB 2 tool. We found statistically significant differences between the FLACS and CPS groups for the mean absolute error (MD = -0.12, 95% CI:-0.22-[-0.02], p = 0.01), the circularity of capsulorhexis (MD = 0.04, 95% CI: 0.04-0.05, p ≤ 0.00001), IOL centration (D = -0.07, 95% CI:-0.09-[-0.05], p ≤ 0.00001), CDE count (MD = -1.75, 95% CI: -2.75-[-0.74], p = 0.0006), mean phacoemulsification time (MD = -12.90, 95% CI:-20.89-[-4.92], p = 0.002), EPT (MD = -0.93, 95% CI: -1.68-[-0.019], p = 0.01) and endothelial cell density loss ((MD = -0.6, 95% CI: -1-[-0.19], p = 0.004). Also, the safety analysis showed a lower incidence of posterior capsule tear (PCT) in the FLACS group (OR =0.29, 95% CI: 0.09-1, p = 0.05). CONCLUSIONS: Our results suggest that FLACS might be helpful for patients with relatively dense cataracts and low preoperative endothelial cell values.


Subject(s)
Cataract Extraction , Laser Therapy , Phacoemulsification , Postoperative Complications , Visual Acuity , Humans , Cataract Extraction/adverse effects , Cataract Extraction/instrumentation , Cataract Extraction/methods , Laser Therapy/adverse effects , Laser Therapy/instrumentation , Laser Therapy/methods , Lens Implantation, Intraocular/adverse effects , Lens Implantation, Intraocular/instrumentation , Lens Implantation, Intraocular/methods , Phacoemulsification/adverse effects , Phacoemulsification/methods , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Randomized Controlled Trials as Topic , Visual Acuity/physiology
17.
Arq. bras. oftalmol ; Arq. bras. oftalmol;87(2): e2021, 2024. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527833

ABSTRACT

ABSTRACT A 59-year-old man presented with a unilateral blurring of vision in his left eye. His left eye's visual acuity was hand movements level. He underwent phacoemulsification surgery, and an intrastromal posterior chamber intraocular lens was implanted. The intrastromal intraocular lens was extracted and a new intraocular lens was implanted. Usinge the Snellen chart, the final best-corrected visual acuity was 20/40. With this case report, we wish to emphasize that a single stepwise clear corneal incision merged with wound-assisted intraocular lens injections can result in intraocular lens misdirection into the corneal stroma. As a result, while performing a misdirected intraocular lens removal, we recommend that the wound be carefully constructed.


RESUMO Um homem de 59 anos apresentou embaçamento visual unilateral no olho esquerdo. Sua acuidade visual nesse olho era no nível de movimentos da mão. O paciente havia se submetido a uma cirurgia de facoemulsificação em que foi feita a implantação intraestromal de uma lente intraocular de câmara posterior. Foi feita a extração dessa lente intraestromal intraocular e uma nova lente intraocular foi implantada. A melhor acuidade visual corrigida final foi de 20/40 pela tabela de Snellen. Com este relato de caso, os autores desejam apontar que uma incisão de degrau único em córnea clara, quando combinada com a injeção de uma lente ocular através da incisão, pode levar a um direcionamento incorreto da lente intraocular para dentro do estroma corneano. Portanto, recomenda-se uma construção cuidadosa da incisão ao se remover uma lente intraocular direcionada incorretamente.

18.
Arq. bras. oftalmol ; Arq. bras. oftalmol;87(4): e2022, 2024. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1557096

ABSTRACT

ABSTRACT We present a case report detailing the successful phacoemulsification surgery with artificial iris implantation for two individuals with oculocutaneous albinism. These women suffered from cataracts, resulting in reduced visual acuity and heightened photophobia due to iris pigmentary epithelium deficiency. The patients underwent phacoemulsification along with prosthetic artificial iris implantation into the posterior chamber. This intervention resulted in improved visual acuity, reduced photophobia and glare, and an overall enhanced quality of life. Our report highlights two cases of successful phacoemulsification and artificial iris implantation in patients with oculocutaneous albinism and cataracts, leading to improved visual acuity, reduced photophobia, and enhanced quality of life. Notably, there are no prior records in South American literature of cataract surgery combined with artificial iris implantation for oculocutaneous albinism patients up to the time of this publication.

19.
Arq. bras. oftalmol ; Arq. bras. oftalmol;87(5): e2023, 2024. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1568841

ABSTRACT

ABSTRACT This document on myopia control is derived from a compilation of medical literature and the collective clinical expertise of an expert committee comprising members from the Brazilian Society of Pediatric Ophthalmology and the Brazilian Society of Contact Lenses and Cornea. To manage myopia in children, the committee recommends corneal topography and biannual visits with cycloplegic refraction, along with annual optical biometry. For fast-progressing myopia, biannual biometry should be considered. Myopic progression is defined as an annual increase in spherical equivalent greater than 0.50 D/year or in axial length greater than 0.3 mm (until 10 years old) or 0.2 mm (above 11 years). The proposed treatments for myopia progression include environmental control, low concentration atropine, defocus glasses, contact lenses, or Ortho-K lenses, and combinations of these methods may be necessary for uncontrolled cases. Treatment should be sustained for at least 2 years. This document serves as a comprehensive guideline for diagnosing, treating, and monitoring pre-myopic and myopic children in Brazil.


RESUMO Esta revisão foi baseada na literatura médica e na experiência clínica de um comitê de especialistas membros da Sociedade Brasileira de Oftalmologia Pediátrica e da Sociedade Brasileira de Lentes de Contato e Córnea. Rotineiramente as crianças devem ser submetidas a topografia da córnea no primeiro exame e visitas semestrais com refração cicloplegiada e biometria óptica anual. A progressão da miopia foi definida como um aumento anual no equivalente esférico maior que 0,50 D/ano ou do comprimento axial maior que 0,3 mm (até 10 anos) ou 0,2 mm (mais de 11 anos). Os tratamentos propostos para a progressão são controle ambiental, atropina em baixa concentração, óculos com defocus, lentes de contato ou ortoceratologia, devendo-se considerar associações para casos não controlados. O tratamento deve ser realizado por pelo menos 2 anos. O presente documento é uma diretriz para diagnóstico, tratamento e acompanhamento de crianças pré-míopes e míopes no Brasil.

20.
Rev. bras. oftalmol ; 83: e0043, 2024. tab
Article in English | LILACS | ID: biblio-1569743

ABSTRACT

ABSTRACT Objective To evaluate intraocular lens power calculation and postoperative refractive errors in patients with high myopia undergoing cataract surgery, comparing predicted target refraction and actual postoperative refraction measured 30 days after surgery with SRK/T formula. Methods This retrospective analysis comprised 39 eyes of 31 patients undergoing cataract surgery through phacoemulsification with in-the-bag IOL implantation. Axial length was measured by partial coherence interferometry or immersion ultrasound biometry, with measurements greater than 26 mm and preoperative myopia greater than -6.0 D Manifest refraction was performed at the 1-month postoperative visit, and the spherical equivalent was analyzed. Results After analysis of 39 eyes of 31 patients undergoing cataract surgery with a mean axial length of 30.4 (standard deviation of 2.2) mm, the mean preoperative refractive spherical equivalent was -15.6 (standard deviation of 7.6) D, ranging from -24.0 to -13.4 D. At 30 days postoperatively, the mean spherical equivalent was -0.35 (standard deviation of 1.1) D, ranging from -2.4 to 2.50 D. Conclusion We encountered a correlation between the absolute refractive error and the dioptric power of the intraocular lens. Against expectations, in our study, ultrasound biometry yielded better results than the optical biometer device, probably due to the small number of patients undergoing optical biometry, suggesting that well-performed immersion biometry can still produce satisfactory results.


RESUMO Objetivo Avaliar os cálculos de potência da lente intraocular e os erros refrativos pós-operatórios em pacientes com alta miopia submetidos à cirurgia de catarata, comparando a refração-alvo prevista e a refração pós-operatória real medida 30 dias após a cirurgia com a fórmula SRK/T. Métodos Esta análise retrospectiva incluiu 39 olhos de 31 pacientes com cirurgia de catarata de facoemulsificação não complicada com implantação de lente intraocular na bolsa. Os comprimentos axiais foram medidos por biometria de coerência óptica ou ultrassônica (imersão), com medidas de axial length (AL) maiores que 26 mm em pacientes com miopia maior que -6.0 D. A refração manifesta foi realizada na consulta pós-operatória de 1 mês, e o equivalente esférico foi analisado. Resultados Após análise de 39 olhos de 31 pacientes submetidos à cirurgia de catarata com AL médio de 30,4 (desvio-padrão de 2,2) mm, o equivalente esférico refrativo médio pré-operatório foi de -15,6 (desvio-padrão de 7,6) D, variando de -24,0 a -13,4 D. Aos 30 dias de pós-operatório, o equivalente esférico médio foi de -0,35 (desvio-padrão de 1,1) D, variando de -2,4 a 2,50 D. Conclusão Encontramos uma correlação entre o erro refrativo absoluto e o poder dióptrico da lente intraocular. Contrariando as expectativas, em nosso estudo, a biometria ultrassônica apresentou melhores resultados que o biômetro óptico, provavelmente devido ao pequeno número de pacientes submetidos à biometria óptica, sugerindo que a biometria de imersão bem executada ainda pode produzir resultados satisfatórios.


Subject(s)
Humans , Refractive Errors , Biometry/methods , Phacoemulsification/methods , Myopia , Refraction, Ocular/physiology , Retrospective Studies , Lens Implantation, Intraocular , Axial Length, Eye , Internship and Residency , Lenses, Intraocular
SELECTION OF CITATIONS
SEARCH DETAIL