Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Magn Reson Med ; 78(6): 2185-2193, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28097733

ABSTRACT

PURPOSE: Multiband pulses are characterized by highly temporally modulated waveforms. Rapid phase or frequency modulation can be extremely demanding on the performance of radiofrequency (RF) pulse generation, which can lead to errors that can be avoided if pulses are restricted to amplitude modulation (AM) only. In this work, three existing multiband pulse design techniques are modified to produce AM waveforms. THEORY AND METHODS: Multiband refocusing pulses were designed using phase-optimization, time-shifting, and root-flipping. Each technique was constrained to produce AM pulses by exploiting conjugate symmetry in their respective frequency domain representations. Pulses were designed using the AM and unconstrained techniques for a range of multiband factors (ie, number of simultaneously excited slices), time-bandwidth products, and slice separations. Performance was compared by examining the resulting effective pulse durations. Phantom and in vivo experiments were conducted for validation. RESULTS: Acquired data confirmed that AM pulses can produce precise results when unconstrained designs may produce artifacts. The average duration of AM pulses is longer than the unconstrained versions. Averaged across a range of parameters, the duration cost for AM pulses was 26, 38, and 20% for phase-optimizing, time-shifting and root-flipping, respectively. CONCLUSIONS: Amplitude modulation multiband pulses can be produced for a relatively small increase in pulse duration. Magn Reson Med 78:2185-2193, 2017. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Subject(s)
Diffusion Magnetic Resonance Imaging , Image Processing, Computer-Assisted , Radio Waves , Algorithms , Artifacts , Computer Simulation , Fourier Analysis , Humans , Models, Statistical , Phantoms, Imaging , Spectrophotometry
2.
Magn Reson Med ; 75(6): 2464-72, 2016 06.
Article in English | MEDLINE | ID: mdl-26997332

ABSTRACT

PURPOSE: We explore the advantages of using a double-ring radiofrequency (RF) array and slice orientation to design parallel transmission (pTx) multiband (MB) pulses for simultaneous multislice (SMS) imaging with whole-brain coverage at 7 Tesla (T). METHODS: A double-ring head array with 16 elements split evenly in two rings stacked in the z-direction was modeled and compared with two single-ring arrays consisting of 8 or 16 elements. The array performance was evaluated by designing band-specific pTx MB pulses with local specific absorption rate (SAR) control. The impact of slice orientations was also investigated. RESULTS: The double-ring array consistently and significantly outperformed the other two single-ring arrays, with peak local SAR reduced by up to 40% at a fixed excitation error of 0.024. For all three arrays, exciting sagittal or coronal slices yielded better RF performance than exciting axial or oblique slices. CONCLUSIONS: A double-ring RF array can be used to drastically improve SAR versus excitation fidelity tradeoff for pTx MB pulse design for brain imaging at 7 T; therefore, it is preferable against single-ring RF array designs when pursuing various biomedical applications of pTx SMS imaging. In comparing the stripline arrays, coronal and sagittal slices are more advantageous than axial and oblique slices for pTx MB pulses. Magn Reson Med 75:2464-2472, 2016. © 2016 Wiley Periodicals, Inc.


Subject(s)
Brain/diagnostic imaging , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/instrumentation , Magnetic Resonance Imaging/methods , Equipment Design , Humans , Models, Biological , Phantoms, Imaging
SELECTION OF CITATIONS
SEARCH DETAIL