Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 85
Filter
1.
Sensors (Basel) ; 24(13)2024 Jul 05.
Article in English | MEDLINE | ID: mdl-39001164

ABSTRACT

Hyperspectral detection of the change rate of organic matter content in agricultural remote sensing requires a high signal-to-noise ratio (SNR). However, due to the large number and efficiency limitation of the components, it is difficult to improve the SNR. This study uses high-efficiency convex grating with a diffraction efficiency exceeding 50% across the 360-850 nm range, a back-illuminated Complementary Metal Oxide Semiconductor (CMOS) detector with a 95% efficiency in peak wavelength, and silver-coated mirrors to develop an imaging spectrometer for detecting soil organic matter (SOM). The designed system meets the spectral resolution of 10 nm in the 360-850 nm range and achieves a swath of 100 km and a spatial resolution of 100 m at an orbital height of 648.2 km. This study also uses the basic structure of Offner with fewer components in the design and sets the mirrors of the Offner structure to have the same sphere, which can achieve the rapid adjustment of the co-standard. This study performs a theoretical analysis of the developed Offner imaging spectrometer based on the classical Rowland circular structure, with a 21.8 mm slit length; simulates its capacity for suppressing the +2nd-order diffraction stray light with the filter; and analyzes the imaging quality after meeting the tolerance requirements, which is combined with the surface shape characteristics of the high-efficiency grating. After this test, the grating has a diffraction efficiency above 50%, and the silver-coated mirrors have a reflection value above 95% on average. Finally, the laboratory tests show that the SNR over the waveband exceeds 300 and reaches 800 at 550 nm, which is higher than some current instruments in orbit for soil observation. The proposed imaging spectrometer has a spectral resolution of 10 nm, and its modulation transfer function (MTF) is greater than 0.23 at the Nyquist frequency, making it suitable for remote sensing observation of SOM change rate. The manufacture of such a high-efficiency broadband grating and the development of the proposed instrument with high energy transmission efficiency can provide a feasible technical solution for observing faint targets with a high SNR.

2.
J Synchrotron Radiat ; 31(Pt 4): 771-778, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38819842

ABSTRACT

In the scope of the latest upgrade of the Swiss Light Source, five hard X-ray beamlines will be constructed or rebuilt. To use synergies between these beamline projects, a concept is developed here for hard X-ray beamlines that is tailored to the new storage ring. Herein, this concept is described from the source, via the front end, to the beamline optics. The latter will be outlined in detail, including a new and modular concept for hard X-ray monochromators, focusing optics and heat-load management. With a simple, easy-to-operate and robust beamline design, the new beamlines will greatly profit from the increased brilliance of the new storage ring. The performance increase is up to four orders of magnitude, while the beamline concept allows for the broad application of experimental techniques, from propagation-based methods, such as phase-contrast tomography, to imaging techniques with nanometre resolution. At the same time, spectroscopy experiments are possible as well as high-performance serial X-ray crystallography.

3.
Open Res Eur ; 4: 18, 2024.
Article in English | MEDLINE | ID: mdl-38779341

ABSTRACT

Background: Measurement of light intensity reaching a point of interest in complex systems is a challenge faced by academia and industry. This study analyzes an optical ray tracing method to predict the radiant intensity reaching a point of interest in a germicidal system. Methods: Implementation was performed by analyzing how the method compares with the discrete ordinate method, radiometry, and actinometry. This study further quantified the effect of the photoreactor quartz tube on the measured intensity for multiple wavelengths. Results: Light intensity losses were estimated to be 10 ± 0.5% for the FX-1 265 source. In contrast, the simulation in a water medium showed an increase of up to 64% in the light intensity delivered to the central part of the tube owing to internal reflections and scattering. Model predictions from ray tracing were successfully compared with the discrete ordinate method (DOM) and experimental data (within ± 6%), ensuring the accurate design of complex systems for water disinfection. Conclusions: The data from simulations address the challenges faced in complex radiation modeling and demonstrate that the method can be utilized as a useful tool for optimization and prediction.


The following study explores a new way to measure the strength of light in complex systems, particularly in water treatment type setups. We used a method called optical ray tracing to predict how much light reaches a specific point in the system and have compared it with other techniques like radiometry and discrete ordinate method to make sure it is valid and accurate. An interesting finding was that the type of tube material, in this case, a quartz tube, affects the intensity of the light. For a specific light source with 265 nm light emitting diodes, we estimate a 10% reduction in light intensity due to the quartz tube (transporter of water through the system) in air. But when the simulation was done in a water medium, we found a 64% increase in light intensity in the center of the tube because of how light bounces around and scatters in water. The optical ray tracing method's predictions closely matched other techniques (within about 6% of error), making it a useful tool for designing systems for water disinfection. The study also builds a complex system and predicts the amount of light reaching certain points of interest. This research helps tackle challenges in modeling complex radiation systems and offers insights into how to optimize and predict the behavior of light in such systems.

4.
Micromachines (Basel) ; 15(4)2024 Mar 26.
Article in English | MEDLINE | ID: mdl-38675254

ABSTRACT

As the next generation of in-vehicle intelligent platforms, the augmented reality heads-up display (AR-HUD) has a huge information interaction capacity, can provide drivers with auxiliary driving information, avoid the distractions caused by the lower head during the driving process, and greatly improve driving safety. However, AR-HUD systems still face great challenges in the realization of multi-plane full-color display, and they cannot truly achieve the integration of virtual information and real road conditions. To overcome these problems, many new devices and materials have been applied to AR-HUDs, and many novel systems have been developed. This study first reviews some key metrics of HUDs, investigates the structures of various picture generation units (PGUs), and finally focuses on the development status of AR-HUDs, analyzes the advantages and disadvantages of existing technologies, and points out the future research directions for AR-HUDs.

5.
Sensors (Basel) ; 24(7)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38610429

ABSTRACT

Sequentially timed all-optical mapping photography is one of the main emerging ultra-fast detection technologies that can be widely applicable to ultra-fast detection at the picosecond level in fields such as materials and life sciences. We propose a new optical structure for an all-optical spatial mapping module that can control the optical field of two-dimensional imaging while improving spectral resolution and detector sensor utilization. The model of optical parameters based on geometrical optics theory for the given structure has been established, and the theoretical analysis of the inter-frame energy crosstalk caused by incident beam spot width, chromatic aberration, and main errors of the periscope array has been conducted. The optical design of the two-dimensional (2D) all-optical spatial mapping module was finally completed using ZEMAX OpticStudio 2018 software. The results show that our optical module can realize targets of 16 frames and 1.25 nm spectral resolution.

6.
Micromachines (Basel) ; 15(3)2024 Mar 13.
Article in English | MEDLINE | ID: mdl-38542633

ABSTRACT

Fingerprint recognition is a widely used biometric authentication method in LED-backlight smartphones. Due to the increasing demand for full-screen smartphones, under-display fingerprint recognition has become a popular trend. In this paper, we propose a design of an optical fingerprint recognition lens for under-display smartphones. The lens is composed of three plastic aspheric lenses, with an effective focal length (EFL) of 0.61 mm, a field of view (FOV) of 126°, and a total track length (TTL) of 2.54 mm. The image quality of the lens meets the target specifications, with MTF over 80% in the center FOV and over 70% in the 0.7 FOV, distortion less than 8% at an image height of 1.0 mm, and relative illumination (RI) greater than 25% at an image height of 1.0 mm. The lens also meets the current industry standards in terms of tolerance sensitivity and Monte Carlo analysis.

7.
Sensors (Basel) ; 24(3)2024 Jan 23.
Article in English | MEDLINE | ID: mdl-38339440

ABSTRACT

The spectrum confocal displacement sensor is an innovative type of photoelectric sensor. The non-contact advantages of this method include the capacity to obtain highly accurate measurements without inflicting any harm as well as the ability to determine the object's surface contour recovery by reconstructing the measurement data. Consequently, it has been widely used in the field of three-dimensional topographic measuring. The spectral confocal displacement sensor consists of a light source, a dispersive objective, and an imaging spectrometer. The scanning mode can be categorized into point scanning and line scanning. Point scanning is inherently present when the scanning efficiency is low, resulting in a slower measurement speed. Further improvements are necessary in the research on the line-scanning type. It is crucial to expand the measurement range of existing studies to overcome the limitations encountered during the detection process. The objective of this study is to overcome the constraints of the existing line-swept spectral confocal displacement sensor's limited measuring range and lack of theoretical foundation for the entire system. This is accomplished by suggesting an appropriate approach for creating the optical design of the dispersive objective lens in the line-swept spectral confocal displacement sensor. Additionally, prism-grating beam splitting is employed to simulate and analyze the imaging spectrometer's back end. The combination of a prism and a grating eliminates the spectral line bending that occurs in the imaging spectrometer. The results indicate that a complete optical pathway for the line-scanning spectral confocal displacement sensor has been built, achieving an axial resolution of 0.8 µm, a scanning line length of 24 mm, and a dispersion range of 3.9 mm. This sensor significantly expands the range of measurements and fills a previously unaddressed gap in the field of analyzing the current stage of line-scanning spectral confocal displacement sensors. This is a groundbreaking achievement for both the sensor itself and the field it operates in. The line-scanning spectral confocal displacement sensor's design addresses a previously unmet need in systematic analysis by successfully obtaining a wide measuring range. This provides systematic theoretical backing for the advancement of the sensor, which has potential applications in the industrial detection of various ranges and complicated objects.

8.
Heliyon ; 10(4): e26305, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38379988

ABSTRACT

Due to the internal environment of highway tunnels, tunnel lighting has scattering, deflection, illuminance, and uniformity problems. Each factor will have a direct impact on drivers. Due to the low illuminance and brightness, the lighting efficiency can be improved by shortening the diodes' distance. The SmileRay LED street light module will be adopted as the primary design structure, and the CREO modeling software will construct the initial lens model. The geometric optics laws will be applied, the LightTools will be used to simulate the second optical lens design, lightbar light source module design, lighting mechanism modifications, etc., and then use the lens light distribution with the DIALux lighting design software to carry out the tunnel lighting simulation of spec verification, and optimize the installation through the results. The simulation results show the tunnel lighting module designed in this research can provide 10499 lm of luminous flux when the lamp energy consumption is only 75 W. The total lamp optical efficiency reaches 97%, and the brightness uniformity comes to 0.755 after the modified installation, which aligns with the CIE 88-2004 tunnel lighting specification standard.

9.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1022838

ABSTRACT

Surgery is currently the only effective treatment for cataract.As the standard of living improves, people's demand for postoperative visual quality increases, and a variety of functional artificial lenses (IOL) have been continuously introduced.The in vitro optical quality testing system is used for the design and optimization of new IOL and for the preliminary clinical study of IOL to evaluate the effects of influencing factors such as IOL material, design, decentration, tilt, rotation, incident light wavelength and pupil diameter on the optical quality of IOL.It is helpful for doctors to fully understand and correctly select IOL. In vitro optical quality test systems mainly include optical testing platform and optical design software.The former can experimentally measure IOL, while the latter can perform optical numerical simulation of IOL. In vitro optical quality test systems have received increasing attention in China in recent years.This article reviews the in vitro optical quality test system of IOL and its clinical application.This article reviews the commonly used in vitro optical quality test systems and their clinical applications, including the measurement and evaluation indicators of in vitro optical quality, the construction of optical test platforms (OptiSpheric ? IOL PRO, Badal Optometer, PMTF, and NIMO) and the measurement principles of optical design software (ZEMAX, OSLO, and VirtualLab), as well as their applications in IOL optical quality evaluation and the limitations of in vitro optical testing.

10.
Nanomaterials (Basel) ; 13(23)2023 Nov 21.
Article in English | MEDLINE | ID: mdl-38063680

ABSTRACT

Tandem solar cells (TSCs) perform a better adaptation of the incident photons in different-energy-level bandgap materials, and overcome the Shockley-Queisser limit, but they require advanced control over the management of light for optimum performance. Nanomaterials and nanostructures offer a vastly improved control over the management of light. Through different optimization techniques, researchers can gain valuable insights regarding the optimization of various parameters of nano-optical designs. Over the past years, the number of studies on this topic has been continuously increasing. The present study reviews various current state-of-the-art optical designs, and provides an overview of the optimization techniques and numerical modeling of TSCs. This paper collected and analyzed different studies published within the years 2015-2022, using systematic literature review techniques, such as specific protocol screening and a search strategy. Seven different optical designs were extracted, along with their advanced local and global optimization methods, which offer a solution to the optical limitations of TSCs.

11.
Sensors (Basel) ; 23(14)2023 Jul 17.
Article in English | MEDLINE | ID: mdl-37514749

ABSTRACT

The near-space atmosphere is thin, and the atmospheric refraction and scattering on optical observation is very small, making it very suitable for wide-area and high-resolution surveillance using high-altitude balloon platforms. This paper adopts a 9344 × 7000 CMOS sensor to obtain high-resolution images, generating large-field-of-view imaging through the swing scanning of the photoelectric sphere and image stitching. In addition, a zoom lens is designed to achieve flexible applications for different scenarios, such as large-field-of-view and high-resolution imaging. The optical design results show that the camera system has good imaging quality within the focal length range of 320 mm-106.7 mm, and the relative distortion values at different focal lengths are less than 2%. The flight results indicate that the system can achieve seamless image stitching at a resolution of 0.2 m@20 km and the imaging field of view angle exceeds 33°. This system will perform other near-space flight experiments to verify its ultra-wide (field of view exceeding 100°) high-resolution imaging application.

12.
Micromachines (Basel) ; 14(6)2023 Jun 20.
Article in English | MEDLINE | ID: mdl-37374857

ABSTRACT

The size of the optical zoom system is important in smartphone camera design, especially as it governs the thickness of the smartphone. We present the optical design of a miniaturized 10× periscope zoom lens for smartphones. To achieve the desired level of miniaturization, the conventional zoom lens can be replaced with a periscope zoom lens. In addition to this change in the optical design, the quality of the optical glass, which also affects the performance of the lens, must be considered. With advancements in the optical glass manufacturing process, aspheric lenses are becoming more widely used. In this study, aspheric lenses are incorporated into a design for a 10× optical zoom lens with a lens thickness of less than 6.5 mm and an eight-megapixel image sensor. Furthermore, tolerance analysis is carried out to prove its manufacturability.

13.
Sensors (Basel) ; 23(9)2023 May 06.
Article in English | MEDLINE | ID: mdl-37177720

ABSTRACT

The secondary-phase grating-based tomographic microscopy system, which is widely used in the biological and life sciences, can observe all the sample multilayer image information simultaneously because it has multifocal points. However, chromatic aberration exists in the grating diffraction, which seriously affects the observation of the image. To correct the chromatic aberration of the tomographic microscope system, this paper proposes a system that adopts blazed gratings and angle-variable reflectors as chromatic aberration correction devices according to the principle of dispersion compensation and Fourier phase-shift theory. A reflector-separated light dispersion-compensated 3D microscopy system is presented to achieve chromatic aberration correction while solving the problem of multilayer image overlap. The theoretical verification and optical design of the system were completed using ZEMAX software. The results show that the proposed system reduced the chromatic aberration of ordinary tomographic microscopy systems by more than 90%, retaining more wavelengths of light information. In addition, the system had a relatively wide range in the color difference compensation element installation position, reducing the difficulty of dispersion compensation element installation. Overall, the results indicate that the proposed system is effective in reducing chromatic aberration in grating diffraction.

14.
Sensors (Basel) ; 23(3)2023 Feb 01.
Article in English | MEDLINE | ID: mdl-36772618

ABSTRACT

The relatively high atmospheric propagation of millimeter-waves (MMW) was found to be one of the most critical reasons for the development of reliable sensors for MMW detection. According to previous research works, it has been already shown that incident MMW radiation on a glow discharge detector (GDD) can increase the discharge current. Hence, the electrical mode of detection can be employed to detect the presence of MMW radiation. In this article, a new design of a row detector using GDDs as pixel elements, and the influence of MMW incidence on GDD's discharge current, were acquired using an elementary data acquisition (DAQ) platform. The DAQ system computes the averaged Fast Fourier Transform (FFT) spectrum of the time signal and returns the FFT results as magnitude based on the level of detection. An FFT-based signal acquisition proved to be a better alternative to the lock-in detection that was commonly used in MMW detection systems. This improved detection circuit provides enhanced noise filtering, thereby resulting in better MMW images within a short time. The overhead expense of the entire system is very low, as it can avoid lock-in amplifier stages that were previously used for signal enhancement. A scanning mechanism using a motorized translation stage (step motor) is involved to place and align the row detector in the image plane. The scanning can be carried out vertically to perform the imaging, by configuring the step motor after selecting the desired step size and position. A simplified version of the MMW detection circuit with a dedicated over-voltage protection facility is presented here. This made the detection system more stable and reliable during its operation. The MMW detection circuit demonstrated in this work was found to be a milestone to develop larger focal plane arrays (FPA) with very inexpensive sensor elements.

15.
Micromachines (Basel) ; 15(1)2023 Dec 28.
Article in English | MEDLINE | ID: mdl-38258183

ABSTRACT

This study proposes a three-lens design with a short lens length and explores the curved imaging plane and performs a relative illumination analysis. There are two ways to reduce the lens length: shortening the back focal and lens group lengths. We derived the relevant parameter relationships of three lenses using the first-order geometric optics theory. The optical lens length can be controlled within 2 mm. The shorter the lens length, the larger the angle of the chief ray in the image space, resulting in an increase in the field curvature and astigmatism. Third-order Seidel aberrations can be effectively reduced by a curved image plane. We also derived the equations for relative illuminance, solid angle, surface transmittance, and internal transmittance for the short three-lens design. The optical lens design uses a curved image plane to shorten the distance from the off-axis beam image space to the image plane and reduce the incident angle of the chief ray on the image plane. The formula and design results verified by Code V software (version 11.2) show that both the solid angle and relative contrast of the lens can be increased. For the proposed three-lens design with a short lens length, the semi-field angle is 32°, F/# is 2.7, the effective focal length is 1.984 mm, the image plane area is 2.16 mm × 1.22 mm, and the curvature radius of the concave image plane is 3.726 mm. Moroever, the MTF (100 lp/mm) is larger than 52%, the lateral color aberration is less than 2.12 µm, the optical distortion is less than 2.00%, and the relative illumination is greater than 68%.

16.
Sensors (Basel) ; 22(24)2022 Dec 16.
Article in English | MEDLINE | ID: mdl-36560275

ABSTRACT

Conventional reconnaissance camera systems have been flown on manned aircraft, where the weight, size, and power requirements are not stringent. However, today, these parameters are important for unmanned aerial vehicles (UAVs). This article provides a solution to the design of airborne large aperture infrared optical systems, based on a monocentric lens that can meet the strict criteria of aerial reconnaissance UAVs for a wide field of view (FOV) and lightness of airborne electro-optical pod cameras. A monocentric lens has a curved image plane, consisting of an array of microsensors, which can provide an image with 368 megapixels over a 100° FOV. We obtained the initial structure of a five-glass (5GS) asymmetric monocentric lens with an air gap, using ray-tracing and global optimization algorithms. According to the design results, the ground sampling distance (GSD) of the system is 0.33 m at 3000 m altitude. The full-field modulation transfer function (MTF) value of the system is more than 0.4 at a Nyquist frequency of 70 lp/mm. We present a primary thermal control method, and the image quality was steady throughout the operating temperature range. This compactness and simple structure fulfill the needs of uncrewed airborne lenses. This work may facilitate the practical application of monocentric lens in UAVs.

17.
Sensors (Basel) ; 22(14)2022 Jul 15.
Article in English | MEDLINE | ID: mdl-35890971

ABSTRACT

The special dispersion and temperature characteristics of diffractive optical element (DOE) make them widely used in optical systems that require both athermalization and achromatic aberrations designs. The multi-layer DOE (MLDOE) can improve the diffraction efficiency of the overall broad waveband, but its diffraction efficiency decreases with changes in ambient temperature. When the ambient temperature changes, the micro-structure heights of MLDOE and the refractive index of the substrate materials change, ultimately affecting its diffraction efficiency, and, further, the optical transform function (OTF). In this paper, the influence of ambient temperature on the diffraction efficiency of MLDOE in a dual-infrared waveband is proposed and discussed, the diffraction efficiency of MLDOE caused by ambient temperature is derived, and a computational imaging method that combines optical design and image restoration is proposed. Finally, a dual-infrared waveband infrared optical system with athermalization and achromatic aberrations corrected based on computational imaging method is designed. Results show that this method can effectively reduce the diffraction efficiency of MLDOE by ambient temperature and improve the imaging quality of hybrid optical systems.

18.
Int J Mol Sci ; 23(12)2022 Jun 20.
Article in English | MEDLINE | ID: mdl-35743277

ABSTRACT

Vibrational spectroscopy techniques are widely used in analytical chemistry, physics and biology. The most prominent techniques are Raman and Fourier-transform infrared spectroscopy (FTIR). Combining both techniques delivers complementary information of the test sample. We present the design, construction, and calibration of a novel bimodal spectroscopy system featuring both Raman and infrared measurements simultaneously on the same sample without mutual interference. The optomechanical design provides a modular flexible system for solid and liquid samples and different configurations for Raman. As a novel feature, the Raman module can be operated off-axis for optical sectioning. The calibrated system demonstrates high sensitivity, precision, and resolution for simultaneous operation of both techniques and shows excellent calibration curves with coefficients of determination greater than 0.96. We demonstrate the ability to simultaneously measure Raman and infrared spectra of complex biological material using bovine serum albumin. The performance competes with commercial systems; moreover, it presents the additional advantage of simultaneously operating Raman and infrared techniques. To the best of our knowledge, it is the first demonstration of a combined Raman-infrared system that can analyze the same sample volume and obtain optically sectioned Raman signals. Additionally, quantitative comparison of confocality of backscattering micro-Raman and off-axis Raman was performed for the first time.


Subject(s)
Spectrum Analysis, Raman , Vibration , Calibration , Spectroscopy, Fourier Transform Infrared/methods , Spectrum Analysis, Raman/methods
19.
Sensors (Basel) ; 22(7)2022 Apr 01.
Article in English | MEDLINE | ID: mdl-35408330

ABSTRACT

Superresolution (SR) imaging technology based on compression coding has always been considered as the key to break through the geometric resolution of the detector. In addition to factors such as the reconstruction algorithm and mounting platform vibrations, the impact of inherent errors in the optical system itself on the reconstruction results of SR imaging is also obvious. To address this issue, a study on the design of the SR optical system and the influence of optical alignment errors on SR imaging was conducted. The design of the SR optical system based on digital micro-mirror device (DMD) for long-wave infrared wavelength was completed, and an athermal analysis of the system was carried out. The design results showed that the SR optical system has good imaging quality in the operating temperature range. The imaging model of the DMD SR imaging optical system is established according to the designed SR optical system. We investigated the influence of various alignment errors, including decenter, tilt, lens interval error and defocus, on the imaging properties of the SR optical system. Various random combinations of alignment errors were introduced into the optical system, respectively, and the SR reconstructed image quality of the imaging system was analyzed using the inverse sensitivity method to obtain the tolerance limits when the system was assembled. Finally, the effectiveness of the method to obtain the alignment tolerance limit of the compression coding SR imaging optical system was verified through a desktop demonstration experiment.

20.
Nanoscale Res Lett ; 16(1): 152, 2021 Oct 09.
Article in English | MEDLINE | ID: mdl-34628557

ABSTRACT

Displays composed of micro-light-emitting diodes (micro-LEDs) are regarded as promising next-generation self-luminous screens and have advantages such as high contrast, high brightness, and high color purity. The luminescence of such a display is similar to that of a Lambertian light source. However, owing to reduction in the light source area, traditional secondary optical lenses are not suitable for adjusting the light field types of micro-LEDs and cause problems that limit the application areas. This study presents the primary optical designs of dielectric and metal films to form highly reflective thin-film coatings with low absorption on the light-emitting surfaces of micro-LEDs to optimize light distribution and achieve full-angle utilization. Based on experimental results with the prototype, that have kept low voltage variation rates, low optical losses characteristics, and obtain the full width at half maximum (FWHM) of the light distribution is enhanced to 165° and while the center intensity is reduced to 63% of the original value. Hence, a full-angle micro-LEDs with a highly reflective thin-film coating are realized in this work. Full-angle micro-LEDs offer advantages when applied to commercial advertising displays or plane light source modules that require wide viewing angles.

SELECTION OF CITATIONS
SEARCH DETAIL