Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
J Biomed Opt ; 29(6): 067001, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38826808

ABSTRACT

Significance: In the realm of cerebrovascular monitoring, primary metrics typically include blood pressure, which influences cerebral blood flow (CBF) and is contingent upon vessel radius. Measuring CBF noninvasively poses a persistent challenge, primarily attributed to the difficulty of accessing and obtaining signal from the brain. Aim: Our study aims to introduce a compact speckle contrast optical spectroscopy device for noninvasive CBF measurements at long source-to-detector distances, offering cost-effectiveness, and scalability while tracking blood flow (BF) with remarkable sensitivity and temporal resolution. Approach: The wearable sensor module consists solely of a laser diode and a board camera. It can be easily placed on a subject's head to measure BF at a sampling rate of 80 Hz. Results: Compared to the single-fiber-based version, the proposed device achieved a signal gain of about 70 times, showed superior stability, reproducibility, and signal-to-noise ratio for measuring BF at long source-to-detector distances. The device can be distributed in multiple configurations around the head. Conclusions: Given its cost-effectiveness, scalability, and simplicity, this laser-centric tool offers significant potential in advancing noninvasive cerebral monitoring technologies.


Subject(s)
Cerebrovascular Circulation , Equipment Design , Spectrum Analysis , Humans , Cerebrovascular Circulation/physiology , Spectrum Analysis/instrumentation , Cost-Benefit Analysis , Reproducibility of Results , Wearable Electronic Devices , Signal-To-Noise Ratio , Lasers , Brain/blood supply , Brain/diagnostic imaging , Brain/physiology , Laser Speckle Contrast Imaging/instrumentation
2.
Neurophotonics ; 11(1): 015004, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38282721

ABSTRACT

Significance: The non-invasive measurement of cerebral blood flow based on diffuse optical techniques has seen increased interest as a research tool for cerebral perfusion monitoring in critical care and functional brain imaging. Diffuse correlation spectroscopy (DCS) and speckle contrast optical spectroscopy (SCOS) are two such techniques that measure complementary aspects of the fluctuating intensity signal, with DCS quantifying the temporal fluctuations of the signal and SCOS quantifying the spatial blurring of a speckle pattern. With the increasing interest in the use of these techniques, a thorough comparison would inform new adopters of the benefits of each technique. Aim: We systematically evaluate the performance of DCS and SCOS for the measurement of cerebral blood flow. Approach: Monte Carlo simulations of dynamic light scattering in an MRI-derived head model were performed. For both DCS and SCOS, estimates of sensitivity to cerebral blood flow changes, coefficient of variation of the measured blood flow, and the contrast-to-noise ratio of the measurement to the cerebral perfusion signal were calculated. By varying complementary aspects of data collection between the two methods, we investigated the performance benefits of different measurement strategies, including altering the number of modes per optical detector, the integration time/fitting time of the speckle measurement, and the laser source delivery strategy. Results: Through comparison across these metrics with simulated detectors having realistic noise properties, we determine several guiding principles for the optimization of these techniques and report the performance comparison between the two over a range of measurement properties and tissue geometries. We find that SCOS outperforms DCS in terms of contrast-to-noise ratio for the cerebral blood flow signal in the ideal case simulated here but note that SCOS requires careful experimental calibrations to ensure accurate measurements of cerebral blood flow. Conclusion: We provide design principles by which to evaluate the development of DCS and SCOS systems for their use in the measurement of cerebral blood flow.

3.
Brain Sci ; 13(10)2023 Sep 25.
Article in English | MEDLINE | ID: mdl-37891734

ABSTRACT

Neurocritical care focuses on monitoring cerebral blood flow (CBF) to prevent secondary brain injuries before damage becomes irreversible. Thus, there is a critical unmet need for continuous neuromonitoring methods to quantify CBF within the vulnerable cortex continuously and non-invasively. Animal models and imaging biomarkers can provide valuable insights into the mechanisms and kinetics of head injury, as well as insights for potential treatment strategies. For this purpose, we implemented an optical technique for continuous monitoring of blood flow changes after a closed head injury in a mouse model, which is based on laser speckle contrast imaging and a fiber camera-based approach. Our results indicate a significant decrease (~10%, p-value < 0.05) in blood flow within 30 min of a closed head injury. Furthermore, the low-frequency oscillation analysis also indicated much lower power in the trauma group compared to the control group. Overall, blood flow has the potential to be a biomarker for head injuries in the early phase of a trauma, and the system is useful for continuous monitoring with the potential for clinical translation.

SELECTION OF CITATIONS
SEARCH DETAIL