Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 29
Filter
1.
Artif Organs ; 2024 Jun 02.
Article in English | MEDLINE | ID: mdl-38825886

ABSTRACT

BACKGROUND: Functional Electrical Stimulation (FES) represents a promising technique for promoting functional recovery in individuals with neuromuscular diseases. Traditionally, current pulses are delivered through self-adhesive hydrogel Ag/AgCl electrodes, which allow a good contact with the skin, are easy-to-use and have a moderate cost. However, skin adherence decreases after a few uses and skin irritations can originate. Recently, textile electrodes have become an attractive alternative as they assure increased durability, easy integration into clothes and can be conveniently cleaned, improving the wearability of FES. However, as various manufacture processes were attempted, their clear validation is lacking. This proof-of-concept study proposes a novel set of ink-based printed textile electrodes and compares them to adhesive hydrogel electrodes in terms of impedance, stimulation performance and perceived comfort. METHODS: The skin-electrode impedance was evaluated for both types of electrodes under different conditions. These electrodes were then used to deliver FES to the Rectus Femoris of 14 healthy subjects to induce its contraction in both isometric and dynamic conditions. This allowed to compare the two types of electrodes in terms of sensory, motor, maximum and pain thresholds, FES-induced range of motion during dynamic tests, FES-induced torque during isometric tests and perceived stimulation comfort. RESULTS: No statistically significant differences were found both in terms of stimulation performance (Wilcoxon test) and comfort (Generalized Linear Mixed Model). CONCLUSION: The results showed that the proposed ink-based printed textile electrodes can be effectively used as alternative to hydrogel ones. Further experiments are needed to evaluate their durability and their response to sterilizability and stretching tests.

2.
Sensors (Basel) ; 23(22)2023 Nov 16.
Article in English | MEDLINE | ID: mdl-38005593

ABSTRACT

The development of smart wearable solutions for monitoring daily life health status is increasingly popular, with chest straps and wristbands being predominant. This study introduces a novel sensorized T-shirt design with textile electrodes connected via a knitting technique to a Movesense device. We aimed to investigate the impact of stationary and movement actions on electrocardiography (ECG) and heart rate (HR) measurements using our sensorized T-shirt. Various activities of daily living (ADLs), including sitting, standing, walking, and mopping, were evaluated by comparing our T-shirt with a commercial chest strap. Our findings demonstrate measurement equivalence across ADLs, regardless of the sensing approach. By comparing ECG and HR measurements, we gained valuable insights into the influence of physical activity on sensorized T-shirt development for monitoring. Notably, the ECG signals exhibited remarkable similarity between our sensorized T-shirt and the chest strap, with closely aligned HR distributions during both stationary and movement actions. The average mean absolute percentage error was below 3%, affirming the agreement between the two solutions. These findings underscore the robustness and accuracy of our sensorized T-shirt in monitoring ECG and HR during diverse ADLs, emphasizing the significance of considering physical activity in cardiovascular monitoring research and the development of personal health applications.


Subject(s)
Activities of Daily Living , Textiles , Humans , Heart Rate/physiology , Electrocardiography , Monitoring, Physiologic/methods
3.
Ann Biomed Eng ; 51(12): 2873-2882, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37598135

ABSTRACT

Neuromuscular electrical stimulation (NMES) of the quadriceps (Q) may increase venous blood flow to reduce the risk of venous thromboembolism. This study assessed whether Q-NMES pants could increase peak venous velocity (PVV) in the femoral vein using Doppler ultrasound and minimize discomfort. On 15 healthy subjects, Q-NMES using textile electrodes integrated in pants was applied with increasing intensity (mA) until the first visible muscle contraction [measurement level (ML)-I] and with an additional increase of six NMES levels (ML II). Discomfort using a numeric rating scale (NRS, 0-10) and PVV were used to assess different NMES parameters: frequency (1, 36, 66 Hz), ramp-up/-down time (RUD) (0, 1 s), plateau time (1.5, 4, and 6 s), and on:off duty cycle (1:1, 1:2, 1:3, 1:4). Q-NMES pants significantly increased PVV from baseline with 93% at ML I and 173% at ML II. Frequencies 36 Hz and 66 Hz and no RUD resulted in significantly higher PVV at both MLs compared to 1 Hz and 1 s RUD, respectively. Plateau time, and duty cycle did not significantly change PVV. Discomfort was only significantly higher with increasing intensity and frequency. Q-NMES pants produces intensity-dependent 2-3-fold increases of venous blood flow with minimal discomfort. The superior NMES parameters were a frequency of 36 Hz, 0 s RUD, and intensity at ML II. Textile-based NMES wearables are promising for non-episodic venous thromboembolism prevention.


Subject(s)
Electric Stimulation Therapy , Venous Thromboembolism , Wearable Electronic Devices , Humans , Quadriceps Muscle/diagnostic imaging , Quadriceps Muscle/physiology , Muscle Contraction/physiology , Electric Stimulation Therapy/methods , Electric Stimulation/methods , Muscle, Skeletal/physiology
4.
Biosensors (Basel) ; 13(7)2023 Jul 13.
Article in English | MEDLINE | ID: mdl-37504127

ABSTRACT

Biopotential electrodes play an integral role within smart wearables and clothing in capturing vital signals like electrocardiogram (ECG), electromyogram (EMG), and electroencephalogram (EEG). This study focuses on dry e-textile electrodes (E1-E6) and a laser-cut knit electrode (E7), to assess their impedance characteristics under varying contact forces and moisture conditions. Synthetic perspiration was applied using a moisture management tester and impedance was measured before and after exposure, followed by a 24 h controlled drying period. Concurrently, the signal-to-noise ratio (SNR) of the dry electrode was evaluated during ECG data collection on a healthy participant. Our findings revealed that, prior to moisture exposure, the impedance of electrodes E7, E5, and E2 was below 200 ohm, dropping to below 120 ohm post-exposure. Embroidered electrodes E6 and E4 exhibited an over 25% decrease in mean impedance after moisture exposure, indicating the impact of stitch design and moisture on impedance. Following the controlled drying, certain electrodes (E1, E2, E3, and E4) experienced an over 30% increase in mean impedance. Overall, knit electrode E7, and embroidered electrodes E2 and E6, demonstrated superior performance in terms of impedance, moisture retention, and ECG signal quality, revealing promising avenues for future biopotential electrode designs.


Subject(s)
Electrocardiography , Textiles , Humans , Electric Impedance , Electrodes
5.
Eur J Appl Physiol ; 123(9): 2013-2022, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37145130

ABSTRACT

PURPOSE: To compare fixed transverse textile electrodes (TTE) knitted into a sock versus motor point placed standard gel electrodes (MPE) on peak venous velocity (PVV) and discomfort, during calf neuromuscular electrical stimulation (calf-NMES). METHODS: Ten healthy participants received calf-NMES with increasing intensity until plantar flexion (measurement level I = ML I), and an additional mean 4 mA intensity (ML II), utilizing TTE and MPE. PVV was measured with Doppler ultrasound in the popliteal and femoral veins at baseline, ML I and II. Discomfort was assessed with a numerical rating scale (NRS, 0-10). Significance was set to p < 0.05. RESULTS: TTE and MPE both induced significant increases in PVV from baseline to ML I and significantly higher increases to ML II, in both the popliteal and femoral veins (all p < 0.001). The popliteal increases of PVV from baseline to both ML I and II were significantly higher with TTE versus MPE (p < 0.05). The femoral increases of PVV from baseline to both ML I and II were not significantly different between TTE and MPE. TTE versus MPE resulted at ML I in higher mA and NRS (p < 0.001), and at ML II in higher mA (p = 0.005) while NRS was not significantly different. CONCLUSION: TTE integrated in a sock produces intensity-dependent increases of popliteal and femoral hemodynamics comparable to MPE, but results in more discomfort at plantar flexion due to higher current required. TTE exhibits in the popliteal vein higher increases of PVV compared to MPE. TRIAL REGISTRATION: Trial_ID: ISRCTN49260430. Date: 11/01/2022. Retrospectively registered.


Subject(s)
Hemodynamics , Leg , Humans , Electric Stimulation/adverse effects , Hemodynamics/physiology , Leg/blood supply , Popliteal Vein/diagnostic imaging , Popliteal Vein/physiology , Ultrasonography
6.
Stud Health Technol Inform ; 302: 682-683, 2023 May 18.
Article in English | MEDLINE | ID: mdl-37203468

ABSTRACT

This case study reports the use of a new textile-electrode system for self-administered Phantom Motor Execution (PME) treatment at home in one patient with Phantom Limb Pain (PLP). In follow-up interviews, the patient reported reduced pain, increased mobility, and improved mental health, and aspects such as motivation, usability, support, and treatment outcome, could be recognized from an earlier study as crucial for successful implementation and adoption of the home-based long-term treatment. The findings are of interest to developers, providers, users, and researchers planning home-based clinical studies and/or scenarios based on technology-assisted treatment.


Subject(s)
Phantom Limb , Humans , Phantom Limb/therapy , Treatment Outcome , Electrodes , Pain Measurement
7.
Sensors (Basel) ; 23(6)2023 Mar 22.
Article in English | MEDLINE | ID: mdl-36992061

ABSTRACT

In this paper, wristband electrodes for hand-to-hand bioimpedance measurements are investigated. The proposed electrodes consist of a stretchable conductive knitted fabric. Different implementations have been developed and compared with Ag/AgCl commercial electrodes. Hand-to-hand measurements at 50 kHz on forty healthy subjects have been carried out and the Passing-Bablok regression method has been exploited to compare the proposed textile electrodes with commercial ones. It is demonstrated that the proposed designs guarantee reliable measurements and easy and comfortable use, thus representing an excellent solution for the development of a wearable bioimpedance measurement system.


Subject(s)
Textiles , Upper Extremity , Humans , Electrodes , Electric Conductivity , Hand
8.
Sensors (Basel) ; 23(3)2023 Jan 18.
Article in English | MEDLINE | ID: mdl-36772153

ABSTRACT

Recording electrical muscle activity using a dense matrix of detection points (high-density electromyography, EMG) is of interest in a range of different applications, from human-machine interfacing to rehabilitation and clinical assessment. The wider application of high-density EMG is, however, limited as the clinical interfaces are not convenient for practical use (e.g., require conductive gel/cream). In the present study, we describe a novel dry electrode (TEX) in which the matrix of sensing pads is screen printed on textile and then coated with a soft polymer to ensure good skin-electrode contact. To benchmark the novel solution, an identical electrode was produced using state-of-the-art technology (polyethylene terephthalate with hydrogel, PET) and a process that ensured a high-quality sample. The two electrodes were then compared in terms of signal quality as well as functional application. The tests showed that the signals collected using PET and TEX were characterised by similar spectra, magnitude, spatial distribution and signal-to-noise ratio. The electrodes were used by seven healthy subjects and an amputee participant to recognise seven hand gestures, leading to similar performance during offline analysis and online control. The comprehensive assessment, therefore, demonstrated that the proposed textile interface is an attractive solution for practical applications.


Subject(s)
Hydrogels , Textiles , Humans , Electromyography , Electrodes , Skin
9.
Front Vet Sci ; 9: 1018213, 2022.
Article in English | MEDLINE | ID: mdl-36483489

ABSTRACT

Robust Animal-Based Measures (ABMs) are fundamental in order to assess animal welfare, however in semi-extensive sheep farming systems is not easy to collect ABMs without inducing additional stress in the animals. Heart rate variability (HRV) is a non-invasive technique of assessing stress levels related to animal welfare. It is considered a sensitive indicator of the functional regulatory characteristics of the autonomic nervous system. Several studies investigated the use of HRV for welfare assessment in dairy cows while research on sheep is scarce. Moreover, assessing HRV in small ruminants at pasture is critical because of the lack of a solution adoptable for field conditions. This study aimed to evaluate if a smart textiles technology is comparable to a Standard base-apex electrocardiogram (ECG) for measuring HRV in small ruminants. Eight healthy Massese dairy sheep were recruited. Standard base-apex ECG and smart textiles technology (Smartex ECG) were simultaneously acquired for 5 min in the standing, unsedated, unclipped sheep. The ECG tracings were recorded when animals were standing quietly. The Bland-Altman test and the linear regression analysis were applied after parameter extraction in time, frequency, and non-linear methods to compare Smartex against standard base-apex ECG systems. The Bland-Altman test was applied to all HRV extracted parameters (Mean RR, pNN50, RMSSD, LF/HF, SampEn, SD1, SD2, stdRR) to evaluate the agreement between the two different instruments, and a linear regression analysis was performed to evaluate the relationship between the two methods. The smart textiles biotechnology was simple to wear and clean. It can be worn without using glue and without shaving the sheep's wool, limiting animal handling and stress. Bland Altman test reported a robust agreement between the two systems. In fact, the regression analysis of HRV parameters showed that half of the parameters recorded had an R2 coefficient >0.75. Results also showed a very small reproducibility coefficient that indicated that the two methods were really close to each other. Smartex textiles technology can be used for HRV evaluation in sheep species as a potential ABM for animal welfare assessment.

10.
Nano Lett ; 22(1): 196-202, 2022 01 12.
Article in English | MEDLINE | ID: mdl-34935386

ABSTRACT

Biofuel cells with good biocompatibility are promising to be used as the power source for flexible and wearable bioelectronics. We here report a type of highly flexible and stretchable biofuel cells, which are enabled by textile electrodes of graphene/carbon nanotubes (G/CNTs) composite and polymer hydrogel electrolyte. The CNT array covalently grown from a graphene layer not only can be served as a conducting substrate to immobilize enzyme molecules but also can provide efficient charge transport channels between the enzyme and graphene electrode. As a result, the developed biofuel cells deliver a high open-circuit voltage of 0.65 V and output power density of 64.2 µW cm-2, which are much higher than previously reported results. Benefiting from the unique textile structure of electrodes and the polymer hydrogel electrolyte, the biofuel cells exhibit high retention of power density after 400 bending cycles and even stretched to a high strain of 60%.


Subject(s)
Bioelectric Energy Sources , Nanotubes, Carbon , Electrodes , Electrolytes , Hydrogels , Nanotubes, Carbon/chemistry , Polymers , Textiles
11.
Chemosphere ; 291(Pt 1): 132738, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34743793

ABSTRACT

This study examines the degradation of atrazine (ATZ) with Pt-modified textile electrodes using an electrochemical method that is comparatively studied in two electrochemical cell configurations: cells with separated anodic and cathodic compartments (divided configuration); and without any separation (undivided configuration). The influence of the presence of chloride ions was studied. The best results were obtained when an undivided cell was used. The morphology and composition of the dispersed Pt coatings were analyzed using field emission scanning electron microscopy (FESEM) and Energy Dispersive X-Ray Analysis. The FESEM analyses confirmed that the textile surface was effectively modified by the electrocatalytic material. High performance liquid chromatography, gas chromatography mass spectrometry, and spectroscopic methods were used to follow the evolution of major oxidation products. Total organic carbon, chemical oxygen demand, and total nitrogen were used to evaluate the degradation efficiency of treated aqueous solutions. The experimental results obtained indicate that the efficiency of the electrochemical treatment was high with a low energy consumption when using electrodes based on textile materials, such as anodes or as cathodes (in particular, in electrolysis without compartment separation). All these can be produced at very competitive prices.


Subject(s)
Atrazine , Water Pollutants, Chemical , Atrazine/analysis , Electrodes , Oxidation-Reduction , Textiles , Water , Water Pollutants, Chemical/analysis
12.
Biosensors (Basel) ; 11(9)2021 Sep 13.
Article in English | MEDLINE | ID: mdl-34562921

ABSTRACT

Wearable physiological monitoring systems are becoming increasingly prevalent in the push toward autonomous health monitoring and offer new modalities for playful and purposeful interaction within human computer interaction (HCI). Sensing systems that can be integrated into garments and, therefore, daily activities offer promising pathways toward ubiquitous integration. The electrocardiogram (ECG) signal is commonly monitored in healthcare and is increasingly utilized as a method of determining emotional and psychological state; however, the complete ECG waveform with the P, Q, R, S, and T peaks is not commonly used, due to the challenges associated with collecting the full waveform with wearable systems. We present woven textile electrodes as an option for garment-integrated ECG monitoring systems that are capable of capturing the complete ECG waveform. In this work, we present the changes in the peak detection performance caused by different sizes, patterns, and thread types with data from 10 human participants. These testing results provide empirically-derived guidelines for future woven textile electrodes, present a path forward for assessing design decisions, and highlight the importance of testing novel wearable sensor systems with more than a single individual.


Subject(s)
Electrocardiography , Textiles , Wearable Electronic Devices , Electrodes , Humans
13.
Sensors (Basel) ; 21(13)2021 Jun 23.
Article in English | MEDLINE | ID: mdl-34201834

ABSTRACT

Multi-channel measurements from the maternal abdomen acquired by means of dry electrodes can be employed to promote long-term monitoring of fetal heart rate (fHR). The signals acquired with this type of electrode have a lower signal-to-noise ratio and different artifacts compared to signals acquired with conventional wet electrodes. Therefore, starting from the benchmark algorithm with the best performance for fHR estimation proposed by Varanini et al., we propose a new method specifically designed to remove artifacts typical of dry-electrode recordings. To test the algorithm, experimental textile electrodes were employed that produce artifacts typical of dry and capacitive electrodes. The proposed solution is based on a hybrid (hardware and software) pre-processing step designed specifically to remove the disturbing component typical of signals acquired with these electrodes (triboelectricity artifacts and amplitude modulations). The following main processing steps consist of the removal of the maternal ECG by blind source separation, the enhancement of the fetal ECG and identification of the fetal QRS complexes. Main processing is designed to be robust to the high-amplitude motion artifacts that corrupt the acquisition. The obtained denoising system was compared with the benchmark algorithm both on semi-simulated and on real data. The performance, quantified by means of sensitivity, F1-score and root-mean-square error metrics, outperforms the performance obtained with the original method available in the literature. This result proves that the design of a dedicated processing system based on the signal characteristics is necessary for reliable and accurate estimation of the fHR using dry, textile electrodes.


Subject(s)
Heart Rate, Fetal , Signal Processing, Computer-Assisted , Algorithms , Artifacts , Electrocardiography , Electrodes , Female , Humans , Pregnancy
14.
Biomed Eng Online ; 20(1): 68, 2021 Jul 12.
Article in English | MEDLINE | ID: mdl-34247646

ABSTRACT

BACKGROUND: Continuous long-term electrocardiography monitoring has been increasingly recognized for early diagnosis and management of different types of cardiovascular diseases. To find an alternative to Ag/AgCl gel electrodes that are improper for this application scenario, many efforts have been undertaken to develop novel flexible dry textile electrodes integrated into the everyday garments. With significant progresses made to address the potential issues (e.g., low signal-to-noise ratio, high skin-electrode impedance, motion artifact, and low durability), the lack of standard evaluation procedure hinders the further development of dry electrodes (mainly the design and optimization). RESULTS: A standard testing procedure and framework for skin-electrode impedance measurement is demonstrated for the development of novel dry textile electrodes. Different representative electrode materials have been screen-printed on textile substrates. To verify the performance of dry textile electrodes, impedance measurements are conducted on an agar skin model using a universal setup with consistent frequency and pressure. In addition, they are demonstrated for ECG signals acquisition, in comparison to those obtained using conventional gel electrodes. CONCLUSIONS: Dry textile electrodes demonstrated similar impedance when in raised or flat structures. The tested pressure variations had an insignificant impact on electrode impedance. Looking at the effect of impedance on ECG signals, a noticeable effect on ECG signal performance metrics was not observed. Therefore, it is suggested that impedance alone is possibly not the primary indicator of signal quality. As well, the developed methods can also serve as useful guidelines for future textile dry-electrode design and testing for practical ECG monitoring applications.


Subject(s)
Electrocardiography , Textiles , Artifacts , Electric Impedance , Electrodes
15.
Biomed Phys Eng Express ; 7(3)2021 04 21.
Article in English | MEDLINE | ID: mdl-33770764

ABSTRACT

Recently, researchers have adapted Bioelectrical Impedance Analysis (BIA) as a new approach to objectively monitor wounds. They have indicated various BIA parameters associated to specific wound types can be linked to wound healing through trend analysis relative to time. However, these studies are conducted using wet electrodes which have been identified as possessing several shortcomings, such as unstable measurements. Thus, the adaption of e-textile electrodes has become an area of interest in measuring biosignals. E-textile electrodes are known to possess a significantly large polarization impedance (Zp) that potentially influences these biosignal measurements. In this study we aim to identify the suitability of e-textile electrodes to monitor wounds using BIA methodologies. By adapting suggested methodologies conducted in-vivo from previous studies, we used an ex-vivo model to observe the behaviour of e-textile electrodes relative to time. This was compared to common clinical wet electrodes, specifically Ag/AgCl. The objective of this study was to identify the BIA parameters that can be used to monitor wounds with e-textile electrodes. By analysing the BIA parameters relative to time, we observed the influence ofZpon these parameters.


Subject(s)
Textiles , Electric Impedance , Electrodes , Nylons , Silver
16.
Sensors (Basel) ; 21(5)2021 Feb 24.
Article in English | MEDLINE | ID: mdl-33668250

ABSTRACT

Textile electrodes, also called textrodes, for biosignal monitoring as well as electrostimulation are central for the emerging research field of smart textiles. However, so far, only the general suitability of textrodes for those areas was investigated, while the influencing parameters on the contact impedance related to the electrode construction and external factors remain rather unknown. Therefore, in this work, six different knitted electrodes, applied both wet and dry, were compared regarding the influence of specific knitting construction parameters on the three-electrode contact impedance measured on a human forearm. Additionally, the influence of applying pressure was investigated in a two-electrode setup using a water-based agar dummy. Further, simulation of an equivalent circuit was used for quantitative evaluation. Indications were found that the preferred electrode construction to achieve the lowest contact impedance includes a square shaped electrode, knitted with a high yarn density and, in the case of dry electrodes, an uneven surface topography consisting of loops, while in wet condition a smooth surface is favorable. Wet electrodes are showing a greatly reduced contact impedance and are therefore to be preferred over dry ones; however, opportunities are seen for improving the electrode performance of dry electrodes by applying pressure to the system, thereby avoiding disadvantages of wet electrodes with fluid administration, drying-out of the electrolyte, and discomfort arising from a "wet feeling".


Subject(s)
Electrodes , Skin , Textiles , Electric Impedance , Equipment Design , Humans
17.
Sensors (Basel) ; 21(3)2021 Jan 26.
Article in English | MEDLINE | ID: mdl-33530394

ABSTRACT

Asthma and chronic obstructive pulmonary disease are associated with nocturnal cough and changes in heart rate. In this work, the authors propose a proof-of-concept non-contact system for performing capacitive electrocardiogram (cECG) and cough-associated capacitive electromyogram (cEMG) measurements using cloth electrodes under a pillowcase. Two electrodes were located along with the approximate vector of lead II ECG and were used for both cECG and cEMG measurements. A signature voltage follower was introduced after each electrode to detect biopotentials with amplitudes of approximately 100 µV. A bootstrapping technique and nonlinear electrical component were combined and implemented in the voltage follower to attain a high input impedance and rapid static discharge. The measurement system was evaluated in a laboratory experiment for seven adult males and one female (average age: 22.5 ± 1.3 yr). The accuracy of R-wave detection for 2-min resting periods was 100% in six subjects, with an overall average of 87.5% ± 30.0%. Clearly visible cEMGs were obtained for each cough motion for all subjects, synchronized with reference EMGs from submental muscle. Although there remains room for improvement in practical use, the proposed system is promising for unobtrusive detection of heart rate and cough over a prolonged period of time.


Subject(s)
Cough , Electrocardiography , Adult , Cough/diagnosis , Electrodes , Electromyography , Female , Heart Rate , Humans , Male , Young Adult
18.
Front Cardiovasc Med ; 8: 806726, 2021.
Article in English | MEDLINE | ID: mdl-34988133

ABSTRACT

Background: With cardiovascular disease continuing to be the leading cause of death and the primary reason for hospitalization worldwide, there is an increased burden on healthcare facilities. Electronic-textile (e-textile)-based cardiac monitoring offers a viable option to allow cardiac rehabilitation programs to be conducted outside of the hospital. Objectives: This study aimed to determine whether signals produced by an e-textile ECG monitor with textile electrodes in an EASI configuration are of sufficient quality to be used for cardiac monitoring. Specific objectives were to investigate the effect of the textile electrode characteristics, placement, and condition on signal quality, and finally to compare results to a reference ECG obtained from a current clinical standard the Holter monitor. Methods: ECGs during different body movements (yawning, deep-breathing, coughing, sideways, and up movement) and activities of daily living (sitting, sitting/standing from a chair, and climbing stairs) were collected from a baseline standard of normal healthy adult male using a novel e-textile ECG and a reference Holter monitor. Each movement or activity was recorded for 5 min with 2-min intervals between each recording. Three different textile area electrodes (40, 60, and 70 mm2) and electrode thicknesses (3, 5, and 10 mm) were considered in the experiment. The effect of electrode placement within the EASI configuration was also studied. Different signal quality parameters, including signal to noise ratio, approximate entropy, baseline power signal quality index, and QRS duration and QT intervals, were used to evaluate the accuracy and reliability of the textile-based ECG monitor. Results: The overall signal quality from the 70 mm2 textile electrodes was higher compared to the smaller area electrodes. Results showed that the ECGs from 3 and 5 mm textile electrodes showed good quality. Regarding location, placing the "A" and "I" electrodes on the left and right anterior axillary points, respectively, showed higher signal quality compared to the standard EASI electrode placement. Wet textile electrodes showed better signal quality compared to their dry counterparts. When compared to the traditional Holter monitor, there was no significant difference in signal quality, which indicated textile monitoring was as good as current clinical standards (non-inferior). Conclusion: The e-textile EASI ECG monitor could be a viable option for real-time monitoring of cardiac activities. A clinical trial in a larger sample is recommended to validate the results in a clinical population.

19.
Sensors (Basel) ; 20(21)2020 Oct 31.
Article in English | MEDLINE | ID: mdl-33142899

ABSTRACT

Long-term electrocardiography (ECG) monitoring is very essential for the early detection and treatment of cardiovascular disorders. However, commercially used silver/silver chloride (Ag/AgCl) electrodes have drawbacks, and these become more obvious during long-term signal monitoring, making them inconvenient for this use. In this study, we developed silver printed textile electrodes from knitted cotton and polyester fabric for ECG monitoring. The surface resistance of printed electrodes was 1.64 Ω/sq for cotton and 1.78 Ω/sq for polyester electrodes. The ECG detection performance of the electrodes was studied by placing three electrodes around the wrist where the electrodes were embedded on an elastic strap with Velcro. The ECG signals collected using textile electrodes had a comparable waveform to those acquired using standard Ag/AgCl electrodes with a signal to noise ratio (SNR) of 33.10, 30.17, and 33.52 dB for signals collected from cotton, polyester, and Ag/AgCl electrodes, respectively. The signal quality increased as the tightness of the elastic strap increased. Signals acquired at 15 mmHg pressure level with the textile electrodes provided a similar quality to those acquired using standard electrodes. Interestingly, the textile electrodes gave acceptable signal quality even after ten washing cycles.


Subject(s)
Electrocardiography , Electrodes , Silver , Textiles , Humans , Laundering , Signal-To-Noise Ratio
20.
Sensors (Basel) ; 20(12)2020 Jun 12.
Article in English | MEDLINE | ID: mdl-32545636

ABSTRACT

Surface electromyography is used for non-invasive evaluations of the neuromuscular system and conventionally involves electrodes placed on the skin to collect electrical signals associated with muscle activity. Recently, embroidered electrodes have been presented as a low-cost alternative to the current commercial solutions. However, the high cost of equipment used in their fabrication forms a barrier to deployment. To address this, this paper presents the first study into the hand-sewing of electrodes for surface electromyography to assess its feasibility as an affordable, alternative means of production. In experiments reported here, batches of hand-sewn electrodes from six novice embroiderers are tested for (i) manufacturing consistency, and (ii) myographic data acquisition against conventional gelled and machine-sewn electrodes. First, the electrical properties of the created electrodes are assessed through simple resistance measurements. Then, linear regression is performed using electromyography data to test if force-variation detection is feasible. The results demonstrate that hand-sewn electrodes provide similar sensitivity to force variation as their machine-sewn counterparts according to the linear regression gradients calculated ( 8.84 using the hand-sewn electrodes and 9.38 using the machine-sewn electrodes, on the flexor muscles of the forearm). This suggests that hand-made, low-cost textile interfaces could be deployed using local production in developing economies.


Subject(s)
Electrodes , Electromyography/instrumentation , Muscle, Skeletal , Textiles , Developing Countries , Equipment Design , Forearm , Humans
SELECTION OF CITATIONS
SEARCH DETAIL