Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Materials (Basel) ; 17(13)2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38998351

ABSTRACT

Factory made steel fiber and steel fiber derived from worn tires was used to develop cement concrete, which was subjected to torsional forces. A dedicated stand for torsion tests, allowing for the measurement of force, deflection, and torsion angle, was used. The test results showed that both the factory-made fiber and the waste steel fiber significantly improved torsional properties of the concrete matrix. The test results of specimens made with waste fiber were characterized by slightly worse results compared to factory-made fibers, but there was a significant improvement in torsional properties compared to samples without fibers. Taking into account the financial and environmental benefits, the application of waste steel fiber recovered from car tires could be an interesting alternative to using commercially sold steel fiber applied for the production of construction elements subjected to torsional forces.

2.
Am J Vet Res ; 85(6)2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38537376

ABSTRACT

OBJECTIVE: The objective of this study is to compare drilling variables and torsional mechanical properties of rabbit femora after bicortical drilling with a 1.5-mm standard surgical drill bit, acrylic drill bit, and K-wire. SAMPLES: 24 pairs of rabbit femora. METHODS: After drilling under controlled axial displacement rate, each bone was biaxially loaded in compression followed by rapid external torsion to failure. Maximum axial thrust force, maximum drill torque, integral of force and displacement, change in temperature, maximum power spectral density of the torque signal, torque vibration, and torque and angle at the yield and failure points were collected. Pre- and postyield stiffness, yield and failure energies, and postyield energy were calculated. RESULTS: The work required to drill through the cis- and transcortices (integral of force and displacement) was greater for the K-wire, followed by the acrylic and then standard drill bits, respectively. The K-wire demonstrated higher maximum torque than the drill bits at the ciscortex, and the force of drilling was significantly greater. The vibration data was greater with the acrylic and standard drill bits than the K-wire. There was no difference in torsional strength between drilling types. CLINICAL RELEVANCE: Mechanical differences exist between different drill bits and K-wire and demonstrate that the K-wire is overall more damaging than the surgical drill bit.


Subject(s)
Bone Wires , Femur , Animals , Rabbits , Femur/surgery , Biomechanical Phenomena , Bone Wires/veterinary , Torsion, Mechanical , Torque
SELECTION OF CITATIONS
SEARCH DETAIL
...