Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.169
Filter
1.
Med Biol Eng Comput ; 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38954265

ABSTRACT

Diastolic vortex ring (VR) plays a key role in the blood-pumping function exerted by the left ventricle (LV), with altered VR structures being associated with LV dysfunction. Herein, we sought to characterize the VR diastolic alterations in ischemic cardiomyopathy (ICM) patients with systo-diastolic LV dysfunction, as compared to healthy controls, in order to provide a more comprehensive understanding of LV diastolic function. 4D Flow MRI data were acquired in ICM patients (n = 15) and healthy controls (n = 15). The λ2 method was used to extract VRs during early and late diastolic filling. Geometrical VR features, e.g., circularity index (CI), orientation (α), and inclination with respect to the LV outflow tract (ß), were extracted. Kinetic energy (KE), rate of viscous energy loss ( EL ˙ ), vorticity (W), and volume (V) were computed for each VR; the ratios with the respective quantities computed for the entire LV were derived. At peak E-wave, the VR was less circular (p = 0.032), formed a smaller α with the LV long-axis (p = 0.003) and a greater ß (p = 0.002) in ICM patients as compared to controls. At peak A-wave, CI was significantly increased (p = 0.034), while α was significantly smaller (p = 0.016) and ß was significantly increased (p = 0.036) in ICM as compared to controls. At both peak E-wave and peak A-wave, EL ˙ VR / EL ˙ LV , WVR/WLV, and VVR/VLV significantly decreased in ICM patients vs. healthy controls. KEVR/VVR showed a significant decrease in ICM patients with respect to controls at peak E-wave, while VVR remained comparable between normal and pathologic conditions. In the analyzed ICM patients, the diastolic VRs showed alterations in terms of geometry and energetics. These derangements might be attributed to both structural and functional alterations affecting the infarcted wall region and the remote myocardium.

2.
J Environ Manage ; 366: 121594, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38971061

ABSTRACT

In the management of urban drainage networks, great interest has been generated in the removal of sediments from sewer systems. The unsteady three-dimensional (3D) flow and turbulent coherent structures surrounding sediment reduction plates in a sewer system are investigated by means of the detached-eddy simulation (DES). Particular emphasis is given to detailing the instantaneous velocity and vorticity fields within the grooves, along with an examination of the three-dimensional, long-term, average flow structure at a Reynolds number of approximately 105. Velocity vectors demonstrate continuous flapping of the flow on the groove wall, periodically interacting with ejections of positive and negative vorticity originating from the grooves. The interaction between the three-dimensional groove flow and the shear flow leads to the downstream transport of patches of positive and negative vorticity, which significantly influence sediment transport. The high-velocity shear flows and strong vortices generated in undulating topography, as identified by the Q-criteria, are the key factors contributing to the efficient sediment reduction capabilities of the sediment reduction plates. The sediment reduction plates with partially enclosed structures exhibit low sedimentation rates in grooves on the plate, a broader acceleration region, and a lesser impact on the flow capacity. The results improve the understanding of the hydrodynamics and turbulent coherent structures surrounding the sediment reduction plates while elucidating the driving factors behind the enhancement of sediment scouring and suspension capacities. These results indicate that the redesign of the plates as partially enclosed structures contributes to further improving their sediment reduction performance.

3.
Comput Biol Med ; 179: 108836, 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38968764

ABSTRACT

Automated identification of cardiac vortices is a formidable task due to the complex nature of blood flow within the heart chambers. This study proposes a novel approach that algorithmically characterizes the identification criteria of these cardiac vortices based on Lagrangian Averaged Vorticity Deviation (LAVD). For this purpose, the Recurrent All-Pairs Field Transforms (RAFT) is employed to assess the optical flow over the Phase Contrast Magnetic Resonance Imaging (PC-MRI), and to construct a continuous blood flow velocity field and reduce errors that arise from the integral process of LAVD. Additionally, Generalized Hough Transform (GHT) is applied for automated depiction of the structure of cardiac vortices. The effectiveness of this method is demonstrated and validated by the computation of the acquired cardiac flow data. The results of this comprehensive visual and analytical study show that the evolution of cardiac vortices can be effectively described and displayed, and the RAFT framework for optical flow can synthesize the in-between PC-MRIs with high accuracy. This allows cardiologists to acquire a deeper understanding of intracardiac hemodynamics and its impact on cardiac functional performance.

4.
ChemSusChem ; : e202401008, 2024 Jul 10.
Article in English | MEDLINE | ID: mdl-38987226

ABSTRACT

Healthcare facilities produce millions of tons of waste annually, with a significant portion consisting of diagnostic plasticware. Here, we introduce a new detection platform that completely replaces traditional assay plates with a piece of membrane, offering a much greener and more sustainable alternative. The membrane, integrated within the portable vortex fluidic device (P-VFD), enables rapid detection of a clinically relevant protein biomarker, urinary p75ECD. This biomarker is utilized to evaluate the prognosis, disease severity, and progression of amyotrophic lateral sclerosis (ALS). This assay has a limit-of-detection (LOD) of 4.03 pg, which is comparable to the plate-based assay (2.24 pg) and has been optimized through a full factorial design of experiments (DOE). P-VFD has great potential in quantifying p75ECD in human biofluids and can significantly reduce the assay time to 5 min compared to the current plate-based p75ECD ELISA assay (3 days), with at least a 4.4-fold reduction in the usage of the detection antibody.

5.
J Control Release ; 373: 161-171, 2024 Jul 13.
Article in English | MEDLINE | ID: mdl-38996922

ABSTRACT

Achieving precise control of nanoparticle size while maintaining consistency and high uniformity is of paramount importance for improving the efficacy of nanoparticle-based therapies and minimizing potential side effects. Although microfluidic technologies are widely used for reliable nanoparticle synthesis, they face challenges in meeting critical homogeneity requirements, mainly due to imperfect mixing efficiency. Furthermore, channel clogging during continuous operation presents a significant obstacle in terms of quality control, as it progressively impedes the mixing behavior necessary for consistent nanoparticle production for therapeutic delivery and complicates the scaling-up process. This study entailed the development of a 3D-printed novel micromixer embedded with hemispherical baffle microstructures, a dual vortex mixer (DVM), which integrates Dean vortices to generate two symmetrical counter-rotating intensified secondary flows. The DVM with a relatively large mixer volume showed rapid mixing characteristics even at a flow rate of several mL min-1 and produced highly uniform lipids, liposomes, and polymer nanoparticles in a size range (50-130 nm) and polydispersity index (PDI) values below 0.15. For the evaluation of products, SARS-CoV-2 Spike mRNA-loaded lipid nanoparticles were examined to verify protein expression in vitro and in vivo using firefly luciferase (FLuc) mRNA. This showed that the performance of the system is comparable to that of a commercial toroidal mixer. Moreover, the vigorous in-situ dispersion of nanoparticles by harnessing the power of vortex physically minimizes the occurrence of aggregation, ensuring consistent production performance without internal clogging of a half-day operation and facilitating quality control of the nanoparticles at desired scales.

6.
J Exp Biol ; 2024 Jul 18.
Article in English | MEDLINE | ID: mdl-39022908

ABSTRACT

Complex hydrodynamics abound in natural streams, yet the selective pressures these impose upon different size classes of fish are not well understood. Attached vortices are produced by relatively large objects that block freestream flow, which fish routinely utilize for flow refuging. To test how flow refuging and the potential harvesting of energy (as seen in Kármán gaiting) varies across size classes in rainbow trout (Oncorhynchus mykiss; fingerling, 8 cm; parr, 14 cm; adult, 21 cm; n=4 per size class), we used a water flume (4,100 L; freestream flow at 65 cm s-1) and created vortices using 45° wing dams of varying size (small=15 cm, medium=31 cm, large=48 cm). We monitored microhabitat selection and swimming kinematics of individual trout and measured the flow field in the wake of wing dams using time-resolved Particle Image Velocimetry (PIV). Trout of each size class preferentially swam in vortices rather than the freestream, but the capacity to flow refuge varied according to the ratio of vortex width to fish length (VW : FL). Consistent refuging behavior was exhibited when VW : FL> 1.5. All size classes exhibited increased wavelength and Strouhal number and decreased tail beat frequency within vortices compared with freestream, suggesting that swimming in vortices requires less power output. In 17% of the trials, fish preferentially swam in a manner that suggests energy harvesting from the shear layer. Our results can inform efforts toward riparian restoration and fishway design to improve salmonid conservation.

7.
Nano Lett ; 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39008655

ABSTRACT

On-chip metasurfaces play a crucial role in bridging the guided mode and free-space light, enabling full control over the wavefront of scattered free-space light in an optimally compact manner. Recently, researchers have introduced various methods and on-chip metasurfaces to engineer the radiation of guided modes, but the total functions that a single metasurface can achieve are still relatively limited. In this work, we propose a novel on-chip metasurface design that can multiplex up to four distinct functions. We can efficiently control the polarization state, phase, angular momentum, and beam profile of the radiated waves by tailoring the geometry of V-shaped nanoantennas integrated on a slab waveguide. We demonstrate several innovative on-chip metasurfaces for switchable focusing/defocusing and for multifunctional generators of orbital angular momentum beams. Our on-chip metasurface design is expected to advance modern integrated photonics, offering applications in optical data storage, optical interconnection, augmented reality, and virtual reality.

8.
J Phys Condens Matter ; 36(42)2024 Jul 19.
Article in English | MEDLINE | ID: mdl-38976991

ABSTRACT

The paper examines ferromagnetic films with strong uniaxial anisotropy of the 'easy plane' type, in which vortex-like inhomogeneities can arise in the presence of artificially created perforations. A universal approach has been developed that makes it possible to reduce the problem of calculating demagnetizing fields in a film of arbitrary thickness to the simplest case, when the film thickness is large. It has been shown that the influence of demagnetizing fields causes the magnetization vector to necessarily move out of the sample plane, and the spatial distribution of magnetization corresponding to this effect has been studied. It has been revealed that the contribution of demagnetizing fields to the total energy of the magnet changes slightly during the transition from a homogeneous structure to an inhomogeneous one.

9.
Bioinspir Biomim ; 19(5)2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38955342

ABSTRACT

This study investigates the role of leading-edge (LE) curvature in flapping wing aerodynamics considering hovering and forward flight conditions. A scaled-up robotic model is towed along its longitudinal axis by a rack gear carriage system. The forward velocity of the robotic model is changed by varying the advance ratioJfrom 0 (hovering) to 1.0. The study reveals that the LE curvature has insignificant influence on the cycle-average aerodynamic lift and drag. However, the time-history lift coefficient shows that the curvature can enhance the lift around the middle of downstroke. This enhanced lift is reduced from 5% to 1.2% asJchanged from 0 to 1.0. Further flow examinations reveal that the LE curvature is beneficial by enhancing circulation only at the outboard wing sections. The enhanced outboard circulation is found to emanate from the less stretched leading-edge vortices (LEVs), weakened trailing-edge vortices (TEVs), and the coherent merging of the tip vortices (TVs) with the minor LEVs as observed from the phase-lock planar digital particle image velocimetry measurements. The far-wake observation shows that the LE curvature enhances the vorticity within the TV, helping to reduce the overall flow fluctuations in the far field. These findings can be extended to explain the predominantly straight LE wing shape with a small amount of curvature only observed near the wing tip for flapping fliers with Re from 103to 104.


Subject(s)
Computer Simulation , Flight, Animal , Models, Biological , Robotics , Wings, Animal , Wings, Animal/physiology , Wings, Animal/anatomy & histology , Flight, Animal/physiology , Animals , Robotics/methods , Biomimetics/methods , Biomechanical Phenomena , Rheology/methods , Equipment Design
10.
Article in English | MEDLINE | ID: mdl-38995353

ABSTRACT

PURPOSE: To evaluate the changes in choroidal thickness 1 year after half-dose photodynamic therapy (PDT) for central serous chorioretinopathy (CSC) using widefield swept-source optical coherence tomography. METHODS: We retrospectively reviewed 21 patients with CSC who unilaterally underwent half-dose PDT and completed a 12-month follow-up. Choroidal thickness was evaluated before and after PDT within an 18-mm circular grid centered on the fovea subdivided into nine areas in the treated and untreated fellow eyes. RESULTS: All 21 treated eyes showed complete resolution of subretinal fluid at 3 months after PDT, without any recurrence at 12 months. The mean choroidal thickness in all nine areas significantly decreased after PDT at 3 months (P < 0.05) and remained unchanged at 12 months (P < 0.05) compared with that at baseline. However, the subtracted choroidal thickness maps between 3 and 12 months detected significant variations among the cases, classified into an enhanced pattern in 10 eyes (47.6%), an attenuated pattern in six eyes (28.6%), and a stable pattern in five eyes (23.8%). The 21 untreated fellow eyes also showed a decrease in mean choroidal thickness in three of the nine subdivided areas at 12 months (P < 0.05), but this decrease was limited posteriorly. CONCLUSION: The reduction in mean choroidal thickness after half-dose PDT for CSC was extensively maintained for 1 year. However, subclinical hemodynamic changes in the entire choroid occurred longitudinally even in the absence of disease recurrence.

11.
Nano Lett ; 24(28): 8679-8686, 2024 Jul 17.
Article in English | MEDLINE | ID: mdl-38949784

ABSTRACT

The simultaneous detection of the orbital angular momentum (OAM) and wavelength offers new opportunities for optical multiplexing. However, because of the dispersion of lens functions for Fourier transformation, the mode conversions at distinct wavelengths cannot be achieved in the same plane. Here we propose an ultracompact achromatic complementary metal oxide semiconductor (CMOS)-integrated OAM mode detector. Specifically, a spatial multiplexed scheme, randomly interleaving the phase distributions for distributing the superposed OAM modes into preset positions at distinct wavelengths, is presented. In addition, such a nanoprinted achromatic OAM detector featuring a microscale size and a short focal length can be integrated onto a CMOS chip. Consequently, the four-bit incident light beams at three discrete wavelengths (633, 532, and 488 nm) can be distinguished with a high degree of accuracy evaluated by the average standardized Euclidean distance of ∼0.75 between the analytical and target results. Our results showcase a miniaturized platform for achieving high-capacity information processing.

12.
Crit Rev Anal Chem ; : 1-14, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38949955

ABSTRACT

The current work is devoted to a comparative analysis of enhanced co-factors in solidified floating organic drop microextraction methods (SFODME) and an environmental assessment. Also, the description of SFODME, with a focus on its applications in the determination of metals in different matrices, was explained. The impact of several parameters, developments, and greenness evaluations was introduced. Especially, the review provides a concise overview of the multiple approaches to SFODME, with an emphasis on environmentally friendly, supported co-factors. These mods include ultrasound, vortex, and air-assisted SFODME procedures. The selectivity and sensitivity increase when co-factors are added to SFODME. Lastly, the analysis also aims to select tools (Analytic GREEnness Metric Approach (AGREE), Red-Green-Blue (RGB12), and Blue Applicability Grade Index (BAGI)) that have been described as environmentally friendly. Additionally provide an explanation of the data collected, compare, and emphasize the advantages of certain characteristics in each tool. Furthermore, case studies and comparisons for three tools were shown.

13.
Brain Res Bull ; 215: 111020, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38909913

ABSTRACT

The study aimed at investigating the impact of an innovative Wake Vortex Alert (WVA) avionics on pilots' operation and mental states, intending to improve aviation safety by mitigating the risks associated with wake vortex encounters (WVEs). Wake vortices, generated by jet aircraft, pose a significant hazard to trailing or crossing aircrafts. Despite existing separation rules, incidents involving WVEs continue to occur, especially affecting smaller aircrafts like business jets, resulting in aircraft upsets and occasional cabin injuries. To address these challenges, the study focused on developing and validating an alert system that can be presented to air traffic controllers, enabling them to warn flight crews. This empowers the flight crews to either avoid the wake vortex or secure the cabin to prevent injuries. The research employed a multidimensional approach including an analysis of human performance and human factors (HF) issues to determine the potential impact of the alert on pilots' roles, tasks, and mental states. It also utilizes Human Assurance Levels (HALs) to evaluate the necessary human factors support based on the safety criticality of the new system. Realistic flight simulations were conducted to collect data of pilots' behavioural, subjective and neurophysiological responses during WVEs. The data allowed for an objective evaluation of the WVA impact on pilots' operation, behaviour and mental states (mental workload, stress levels and arousal). In particular, the results highlighted the effectiveness of the alert system in facilitating pilots' preparation, awareness and crew resource management (CRM). The results also highlighted the importance of avionics able to enhance aviation safety and reducing risks associated with wake vortex encounters. In particular, we demonstrated how providing timely information and improving situational awareness, the WVA will minimize the occurrence of WVEs and contribute to safer aviation operations.

14.
Sensors (Basel) ; 24(11)2024 May 30.
Article in English | MEDLINE | ID: mdl-38894326

ABSTRACT

Vibration diagnostics based on vibroacoustic signal data belong to the most common ways to monitor the technical condition of equipment and technical structures. The paper considers the general issues of vibration-based diagnostics and shows that in general, it is required to monitor both axial and torsional oscillations, as well as the inclination angle, occurring during the operation of various technical objects. To comprehensively monitor these parameters, a hybrid vibration sensor is proposed, simultaneously implementing three operating modes: recording linear displacements of the vibrating object; recording the rotation angle of the object at its torsional oscillations; recording the object angular deviation from the vertical component of the natural local geomagnetic field, i.e., the inclinometer mode. The proposed hybrid sensor design is described, and a theoretical analysis of the sensor's operation in each of the aforementioned operating modes is performed. The authors show that in the inclinometer mode the sensor actually operates as a fluxgate meter. Generalizing the results of the sensor's operation simultaneously in all three operating modes, an equation for the total output data signal has been obtained, which allows for obtaining the required information on the current values of linear displacements and rotation and inclination angles by selectively filtering it with respective three filters tuned to specific frequencies. The experimental studies of the proposed hybrid vibration sensor confirmed its ability to record various vibrational disturbances and changes in the inclination angle of the monitored object.

15.
Sci Rep ; 14(1): 13423, 2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38862618

ABSTRACT

To effectively control the dust generated by coal mining operations, a new type of cyclonic pneumatic mist curtain dust control device was developed. Using CFD software, numerical simulations were conducted on the internal airflow velocity field, the exit velocity of the cyclonic pneumatic mist curtain, and the mist droplet particle field of the curtain. Experiments were carried out to measure the spray coverage, droplet size, and the dust control performance of the model device. The results indicate that when the water pump supply pressure is 8 MPa, the fan supply wind speed is 12 m/s, and the nozzle installation angle is 75 degrees, the cyclonic pneumatic mist curtain dust control device model operates under optimal conditions. The effective coverage of the cyclonic mist curtain is 380 × 3300 mm, fully suppressing dust generation on one side of the curtain. An optimal dust removal distance of about 90 cm was determined. After installing the cyclonic pneumatic mist curtain dust control device, the average dust reduction efficiency for respirable dust reached 91.07%, and the overall dust reduction efficiency achieved 93.34%.

16.
Sci Total Environ ; 945: 174070, 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-38901596

ABSTRACT

Coral reefs consist of various alive elements with specific biological functions. Tubular sponges, as the main coral reefs' constituents, have a marvelous mechanism. They receive nutrients by suctioning from the perforated body (Ostia) and pumping the un-digested materials through the water column from the top mouth (Osculum). This mechanism can be an inspiration for making a device to control or improve sediment/pollutant transport. In the current study, an attempt has been made to evaluate an inspired concept's effects on flow hydrodynamics. In this regard, OpenFOAM® V. 1812 (interFOAM solver) and image processing technique were deployed. The perforated finite-height cylinders (height to diameter ratio of 2.5) with various suction/pump discharges (i.e., J = 150, 300, 350, 400, 450, and 600 lit/h) were considered. The results indicated that increasing the outflow discharge (J ≥ 600 lit/h) could widen the wake by flapping the shear layer. In the vertical plane, the results showed that dipole vortices turned into quadrupole vortex. On the free surface, tip-vortices and counter-rotating vortex pairs (CRVP) generated saw-toothed vortices on two sides of the cylinder. Generating these unique vortices is proof of enhancing the momentum exchange through the water column.

17.
Med Res Arch ; 12(5)2024 May.
Article in English | MEDLINE | ID: mdl-38911991

ABSTRACT

Respiratory fluid dynamics is integral to comprehending the transmission of infectious diseases and the effectiveness of interventions such as face masks and social distancing. In this research, we present our recent studies that investigate respiratory particle transport via high-fidelity large eddy simulation coupled with the Lagrangian particle tracking method. Based on our numerical simulation results for human respiratory events with and without face masks, we demonstrate that facial masks could significantly suppress particle spreading. The studied respiratory events include coughing and normal breathing through mouth and nose. Using the Lagrangian particle tracking simulation results, we elucidated the transport pathways of saliva particles during inhalation and exhalation of breathing cycles, contributing to our understanding of respiratory physiology and potential disease transmission routes. Our findings underscore the importance of respiratory fluid dynamics research in informing public health strategies to reduce the spread of respiratory infections. Combining advanced mathematical modeling techniques with experimental data will help future research on airborne disease transmission dynamics and the effectiveness of preventive measures such as face masks.

18.
Int J Pharm ; 660: 124335, 2024 Jul 20.
Article in English | MEDLINE | ID: mdl-38897488

ABSTRACT

Nanoparticle-mediated thermotherapeutic research strives innovative, multifunctional, efficient, and safe treatments. Our study introduces a novel nanoplatform: the hollow magnetic vortex nanorings within a polydopamine layer (HMVNp), which exhibit dual functionality as magnetic and photothermal agents. Utilizing a "Dual-mode" approach, combining an alternating magnetic field (AMF) with near-infrared (NIR) laser irradiation, HMVNp demonstrated a significant enhancement in heating efficacy (58 ± 8 %, SAR = 1441 vs 1032 W/g) over traditional solid magnetite nanoparticles coated with polydopamine (SMNp). The unique geometry larger surface area to volume ratio facilitates efficient magnetic vortex dynamics and enhanced heat transfer. Addressing the challenge of heat resistant heat shock protein (Hsp) expression, encapsulated quercetin (Q) within HMVNp leverages tumor acidity and dual-mode thermal therapy to enhance release, showing a 28.8 ± 6.81 % increase in Q loading capacity compared to traditional SMNp. Moreover, HMVNp significantly improves contrast for both magnetic resonance imaging (MRI) and photoacoustic imaging (PAI), with an approximately 62 % transverse relaxation (R2 = 81.5 vs 31.6 mM-1s-1 [Fe]). In vivo studies showed that while single treatments slowed tumor growth, dual-mode therapy with quercetin significantly reduced tumors and effectively prevented metastases. Our study highlights the potential of HMVNp/Q as a versatile agent in thermotherapeutic interventions, offering improved diagnostic imaging capabilities.


Subject(s)
Hyperthermia, Induced , Indoles , Magnetic Resonance Imaging , Polymers , Quercetin , Quercetin/administration & dosage , Quercetin/chemistry , Quercetin/pharmacology , Indoles/chemistry , Indoles/administration & dosage , Polymers/chemistry , Animals , Magnetic Resonance Imaging/methods , Hyperthermia, Induced/methods , Mice , Theranostic Nanomedicine/methods , Cell Line, Tumor , Photoacoustic Techniques/methods , Magnetite Nanoparticles/chemistry , Humans , Female , Mice, Nude , Mice, Inbred BALB C , Neoplasms/therapy , Neoplasms/drug therapy , Neoplasms/diagnostic imaging , Photothermal Therapy/methods , Nanoparticles/chemistry
19.
Anal Bioanal Chem ; 416(18): 4057-4070, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38842689

ABSTRACT

A novel ferrofluid prepared from a hydrophobic deep eutectic solvent (DES) and Fe3O4@graphite composite materials was introduced as a green microextraction medium for the separation and enrichment of trace estrogens in real samples. It was found that the ferrofluid greatly improved the capacity and selectivity of target analytes, benefiting from the enrichment of both DES and Fe3O4@graphite composite materials. Using a combination of high-performance liquid chromatography-fluorescence detection (HPLC-FLD) and vortex-assisted liquid-liquid microextraction (VALLME), a new method was established for simultaneous rapid processing and accurate determination of three estrogens (estradiol [E2], estriol [E3], and ethinyl estradiol [EE2]) in environmental water and urine samples. Key parameters affecting the extraction efficiency were optimized using a single-factor approach and response surface methodology. Under optimal conditions, this method yielded a low limit of detection (1.01 ng L-1, 3.03 ng L-1, and 25.0 ng L-1 for EE2, E2, and E3, respectively), wide linear range (3-200,000 ng L-1), high enrichment factors (9.81-47.2), and satisfactory recovery (73.8-129.0%). Compared with traditional analytical techniques, this method avoids the use of volatile toxic organic extraction solvents and cumbersome phase separation operations.


Subject(s)
Estrogens , Hydrophobic and Hydrophilic Interactions , Limit of Detection , Liquid Phase Microextraction , Water Pollutants, Chemical , Estrogens/urine , Estrogens/analysis , Water Pollutants, Chemical/urine , Water Pollutants, Chemical/analysis , Liquid Phase Microextraction/methods , Chromatography, High Pressure Liquid/methods , Deep Eutectic Solvents/chemistry , Humans
20.
ACS Appl Mater Interfaces ; 16(24): 30671-30684, 2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38843203

ABSTRACT

Indoleamine 2,3-dioxygenase (IDO), highly expressed in hepatocellular carcinoma (HCC), plays a pivotal role in creating an immune-suppressive tumor microenvironment. Inhibiting IDO activity has emerged as a promising immunotherapeutic strategy; however, the delivery of IDO inhibitors to the tumor site is constrained, limiting their therapeutic efficacy. In this study, we developed a magnetic vortex nanodelivery system for the targeted delivery of the IDO inhibitor NLG919, integrated with magnetic hyperthermia therapy to reverse the immune-suppressive microenvironment of liver cancer and inhibit tumor growth. This system comprises thermoresponsive polyethylenimine-coated ferrimagnetic vortex-domain iron oxide nanorings (PI-FVIOs) loaded with NLG919 (NLG919/PI-FVIOs). Under thermal effects, NLG919 can be precisely released from the delivery system, counteracting IDO-mediated immune suppression and synergizing with NLG919/PI-FVIOs-mediated magnetothermodynamic (MTD) therapy-induced immunogenic cell death (ICD), resulting in effective HCC suppression. In vivo studies demonstrate that this combination therapy significantly inhibits tumor growth and metastasis by enhancing the accumulation of cytotoxic T lymphocytes and suppressing regulatory T cells within the tumor. Overall, our findings reveal that NLG919/PI-FVIOs can induce a potent antitumor immune response by disrupting the IDO pathway and activating the ICD, offering a promising therapeutic avenue for HCC treatment.


Subject(s)
Indoleamine-Pyrrole 2,3,-Dioxygenase , Liver Neoplasms , Tumor Microenvironment , Indoleamine-Pyrrole 2,3,-Dioxygenase/metabolism , Indoleamine-Pyrrole 2,3,-Dioxygenase/antagonists & inhibitors , Animals , Tumor Microenvironment/drug effects , Mice , Humans , Liver Neoplasms/therapy , Liver Neoplasms/pathology , Liver Neoplasms/drug therapy , Liver Neoplasms/immunology , Hyperthermia, Induced , Carcinoma, Hepatocellular/therapy , Carcinoma, Hepatocellular/pathology , Carcinoma, Hepatocellular/immunology , Carcinoma, Hepatocellular/drug therapy , Cell Line, Tumor , Mice, Inbred BALB C , Antineoplastic Agents/chemistry , Antineoplastic Agents/pharmacology , Imidazoles , Isoindoles
SELECTION OF CITATIONS
SEARCH DETAIL