Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 4.628
Filter
1.
Bone Joint J ; 106-B(5 Supple B): 17-24, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38689571

ABSTRACT

Aims: Periacetabular osteotomy (PAO) is the preferred treatment for symptomatic acetabular dysplasia in adolescents and young adults. There remains a lack of consensus regarding whether intra-articular procedures such as labral repair or improvement of femoral offset should be performed at the time of PAO or addressed subsequent to PAO if symptoms warrant. The purpose was to determine the rate of subsequent hip arthroscopy (HA) in a contemporary cohort of patients, who underwent PAO in isolation without any intra-articular procedures. Methods: From June 2012 to March 2022, 349 rectus-sparing PAOs were performed and followed for a minimum of one year (mean 6.2 years (1 to 11)). The mean age was 24 years (14 to 46) and 88.8% were female (n = 310). Patients were evaluated at final follow-up for patient-reported outcome measures (PROMs). Clinical records were reviewed for complications or subsequent surgery. Radiographs were reviewed for the following acetabular parameters: lateral centre-edge angle, anterior centre-edge angle, acetabular index, and the alpha-angle (AA). Patients were cross-referenced from the two largest hospital systems in our area to determine if subsequent HA was performed. Descriptive statistics were used to analyze risk factors for HA. Results: A total of 16 hips (15 patients; 4.6%) underwent subsequent HA with labral repair and femoral osteochondroplasty, the most common interventions. For those with a minimum of two years of follow-up, 5.3% (n = 14) underwent subsequent HA. No hips underwent total hip arthroplasty and one revision PAO was performed. Overall, 17 hips (4.9%) experienced a complication and 99 (26.9%) underwent hardware removal. All PROMs improved significantly postoperatively. Radiologically, 80% of hips (n = 279) reached the goal for acetabular correction (77% for acetbular index and 93% for LCEA), with no significant differences between those who underwent subsequent HA and those who did not. Conclusion: Rectus-sparing PAO is associated with a low rate of subsequent HA for intra-articular pathology at a mean of 6.2 years' follow-up (1 to 11). Acetabular correction alone may be sufficient as the primary intervention for the majority of patients with symptomatic acetabular dysplasia.


Subject(s)
Acetabulum , Arthroscopy , Osteotomy , Humans , Female , Male , Adolescent , Osteotomy/methods , Adult , Arthroscopy/methods , Acetabulum/surgery , Acetabulum/diagnostic imaging , Young Adult , Middle Aged , Incidence , Retrospective Studies , Patient Reported Outcome Measures , Postoperative Complications/epidemiology , Follow-Up Studies , Reoperation/statistics & numerical data
2.
Acta Orthop Belg ; 90(1): 17-25, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38669644

ABSTRACT

Today, acetabular surgeons in training have to learn ilioinguinal and anterior intrapelvic approaches (AIP). The aim of this study was to describe the 5-years learning curve of a surgeon. Objective was to assess clinical and radiological results; and to assess factors which could influence this learning curve. Between November 2015 and May 2020, patients with an acetabular fracture operated by the surgeon during the 5-years learning curve with an anterior approach were included in this single-center retrospective study based on a prospective database. Epidemiological, operative, clinical, radiological and complications data's were collected. To assess learning-curve effect the series was divided into two groups: first 2.5-years and last 2-years. Subgroup analysis were performed according to the surgical approach, to the reduction quality and the prognostic factors. In total, 46 patients were included, 23 in period 1 and 23 in period 2. 16 patients (35%) had ilioinguinal approach and 30 patients (65%) had modified Stoppa-Cole approach. At mean follow-up of 24 months, 38 patients (83%) were reviewed. Anatomical reduction (< 1 mm) was achieved in 28 patients (60.9%) with a 9% rate of perioperative complications and 37% rate of post-operative complications. In conclusion, this study gives a realistic overview of the learning curve of anterior approaches in acetabular fractures surgery. Our results should encourage surgeons, while keeping in mind how much this surgery can be challenging, with high rate of complications and difficulty to obtain a systematic anatomical reduction.


Subject(s)
Acetabulum , Fractures, Bone , Learning Curve , Humans , Acetabulum/injuries , Acetabulum/surgery , Acetabulum/diagnostic imaging , Male , Female , Retrospective Studies , Fractures, Bone/surgery , Middle Aged , Adult , Fracture Fixation, Internal/methods , Postoperative Complications/epidemiology , Aged
3.
Acta Orthop Belg ; 90(1): 139-141, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38669664

ABSTRACT

Liner dissociations are rare but catastrophic complications after THA, requiring revision surgery. Although this complication has been well documented in THA with modular components, it has been rarely described in preassembled designs. In this report we present a rare case of liner dissociation in a ceramic-on-ceramic pre-assembled cup design. A 41-year-old man who received THA seven years ago, presented with sudden pain in the hip. Radiographic examination confirmed a small dissociation of the liner component in the acetabular shell, as well as radiolucency between the acetabular shell and the ceramic liner, and pneumarthrosis. Revision surgery was carried out six weeks following the liner dissociation. To make an accurate diagnosis, orthopaedic surgeons must be aware of the symptoms of liner dissociation.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip , Ceramics , Hip Prosthesis , Prosthesis Failure , Reoperation , Humans , Male , Adult , Hip Prosthesis/adverse effects , Arthroplasty, Replacement, Hip/adverse effects , Acetabulum/surgery , Acetabulum/diagnostic imaging , Prosthesis Design
4.
Sci Rep ; 14(1): 9747, 2024 04 28.
Article in English | MEDLINE | ID: mdl-38679649

ABSTRACT

The study aimed to explore an extra-articular screw placement strategy in Stoppa approach. Radiographic data of patients who underwent pelvic computed tomography from January 2016 to June 2017 were imported into Materiaise's interactive medical image control system software for three-dimensional reconstruction. Superior and lower margins of acetabulum and ipsilateral pelvic brim could be observed simultaneously through inlet-obturator view. A horizontal line from superior acetabular margin intersected pelvic brim at point "A" and another vertical line from lower margin intersected pelvic brim at point "B" were drawn, respectively. Lengths form sacroiliac joint to "A" (a), "A" to "B" (b), and "B" to pubic symphysis (c) were measured. Patients were divided into four groups depending on gender and side difference of measured hemi-pelvis: male left, male right, female left, and female right. Lengths of adjacent holes (d) and spanning different holes (e) of different plates were also measured. Mean lengths of a, b, c in four groups were 40.94 ± 1.85 mm, 40.09 ± 1.93 mm, 41.78 ± 3.62 mm, and 39.77 ± 2.23 mm (P = 0.078); 40.65 ± 1.58 mm, 41.48 ± 1.64 mm, 40.40 ± 1.96 mm, and 40.66 ± 1.70 mm (P = 0.265); 57.03 ± 3.41 mm, 57.51 ± 3.71 mm, 57.84 ± 4.40 mm, and 59.84 ± 4.35 mm (P = 0.165), respectively. Mean d length of different plates was 12.23 mm. Average lengths spanning 1, 2, 3 and 4 holes were 19.33 mm, 31.58 mm, 43.80 mm, and 55.93 mm. Our data showed that zones a and c could be safely inserted three and four screws. Penetration into hip joint could be avoided when vacant 3-hole drilling was conducted in zone b. Fracture line in zone b could serve as a landmark for screw placement.


Subject(s)
Bone Screws , Imaging, Three-Dimensional , Tomography, X-Ray Computed , Humans , Female , Male , Imaging, Three-Dimensional/methods , Middle Aged , Adult , Fracture Fixation, Internal/methods , Aged , Pelvic Bones/surgery , Pelvic Bones/diagnostic imaging , Acetabulum/surgery , Acetabulum/diagnostic imaging , Sacroiliac Joint/surgery , Sacroiliac Joint/diagnostic imaging , Fractures, Bone/surgery , Fractures, Bone/diagnostic imaging
5.
Sci Rep ; 14(1): 9475, 2024 04 24.
Article in English | MEDLINE | ID: mdl-38658572

ABSTRACT

The Periacetabular Osteotomy is a technically demanding procedure that requires precise intraoperative evaluation of pelvic anatomy. Fluoroscopic images pose a radiation risk to operating room staff, scrubbed personnel, and the patient. Most commonly, a Standard Fluoroscope with an Image Intensifier is used. Our institution recently implemented the novel Fluoroscope with a Flat Panel Detector. The purpose of this study was to compare radiation dosage and accuracy between the two fluoroscopes. A retrospective review of a consecutive series of patients who underwent Periacetabular Osteotomy for symptomatic hip dysplasia was completed. The total radiation exposure dose (mGy) was recorded and compared for each case from the standard fluoroscope (n = 27) and the flat panel detector (n = 26) cohorts. Lateral center edge angle was measured and compared intraoperatively and at the six-week postoperative visit. A total of 53 patients (96% female) with a mean age and BMI of 17.84 (± 6.84) years and 22.66 (± 4.49) kg/m2 (standard fluoroscope) and 18.23 (± 4.21) years and 21.99 (± 4.00) kg/m2 (flat panel detector) were included. The standard fluoroscope averaged total radiation exposure to be 410.61(± 193.02) mGy, while the flat panel detector averaged 91.12 (± 49.64) mGy (p < 0.0001). The average difference (bias) between intraoperative and 6-week postoperative lateral center edge angle measurement was 0.36° (limits of agreement: - 3.19 to 2.47°) for the standard fluoroscope and 0.27° (limits of agreement: - 2.05 to 2.59°) for the flat panel detector cohort. Use of fluoroscopy with flat panel detector technology decreased the total radiation dose exposure intraoperatively and produced an equivalent assessment of intraoperative lateral center edge angle. Decreasing radiation exposure to young patients is imperative to reduce the risk of future comorbidities.


Subject(s)
Osteotomy , Radiation Dosage , Radiation Exposure , Humans , Fluoroscopy/methods , Female , Male , Radiation Exposure/prevention & control , Retrospective Studies , Osteotomy/instrumentation , Osteotomy/methods , Adolescent , Young Adult , Acetabulum/surgery , Acetabulum/diagnostic imaging , Adult , Hip Dislocation/prevention & control , Hip Dislocation/diagnostic imaging , Hip Dislocation/etiology , Child
6.
J Robot Surg ; 18(1): 160, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38578350

ABSTRACT

Robotic assisted (RA) total hip arthroplasty (THA) offers improved acetabular component placement and radiographic outcomes, but inconsistent assessment methods of its learning curves render the evaluation of adopting novel platforms challenging. Therefore, we conducted a systematic review to assess the learning curve associated with RA-THA, both tracking a surgeon's performance across initial cases and comparing their performance to manual THA (M-THA). PubMed, MEDLINE, EBSCOhost, and Google Scholar were searched on June 16, 2023, to identify studies published between January 1, 2000 and June 16, 2023 (PROSPERO registration: CRD42023437339). The query yielded 655 unique articles, which were screened for eligibility. The final analysis included 11 articles, evaluating 1351 THA procedures. Risk of bias was assessed via the Methodological Index for Nonrandomized Studies (MINORS) tool. The mean MINORS score was 21.3 ± 0.9. RA-THA provided immediate improvements in acetabular component placement accuracy and radiographic outcomes compared to M-THA, with little to no experience required to achieve peak proficiency. A modest learning curve (12-17 cases) was associated with operative time, which was elevated compared to M-THA (+ 9-13 min). RA-THA offers immediate advantages to M-THA for component placement accuracy and radiographic outcomes. Surgeons should expect to experience increased operative times, which become less pronounced or equivalent to M-THA after a modest caseload.


Subject(s)
Arthroplasty, Replacement, Hip , Robotic Surgical Procedures , Surgery, Computer-Assisted , Humans , Arthroplasty, Replacement, Hip/methods , Learning Curve , Robotic Surgical Procedures/methods , Acetabulum/diagnostic imaging , Acetabulum/surgery , Surgery, Computer-Assisted/methods
7.
Bone Joint J ; 106-B(5 Supple B): 40-46, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38688483

ABSTRACT

Aims: Ganz's studies made it possible to address joint deformities on both the femoral and acetabular side brought about by Perthes' disease. Femoral head reduction osteotomy (FHRO) was developed to improve joint congruency, along with periacetabular osteotomy (PAO), which may enhance coverage and containment. The purpose of this study is to show the clinical and morphological outcomes of the technique and the use of an implemented planning approach. Methods: From September 2015 to December 2021, 13 FHROs were performed on 11 patients for Perthes' disease in two centres. Of these, 11 hips had an associated PAO. A specific CT- and MRI-based protocol for virtual simulation of the corrections was developed. Outcomes were assessed with radiological parameters (sphericity index, extrusion index, integrity of the Shenton's line, lateral centre-edge angle (LCEA), Tönnis angle), and clinical parameters (range of motion, visual analogue scale (VAS) for pain, Merle d'Aubigné-Postel score, modified Harris Hip Score (mHHS), and EuroQol five-dimension five-level health questionnaire (EQ-5D-5L)). Early and late complications were reported. Results: The mean follow-up was 39.7 months (standard deviation (SD) 26.4). The mean age at surgery was 11.4 years (SD 1.6). No major complications were recorded. One patient required a total hip arthroplasty. Mean femoral head sphericity increased from 46.8% (SD 9.34%) to 70.2% (SD 15.44; p < 0.001); mean LCEA from 19.2° (SD 9.03°) to 44° (SD 10.27°; p < 0.001); mean extrusion index from 37.8 (SD 8.70) to 7.5 (SD 9.28; p < 0.001); and mean Tönnis angle from 16.5° (SD 12.35°) to 4.8° (SD 4.05°; p = 0.100). The mean VAS improved from 3.55 (SD 3.05) to 1.22 (1.72; p = 0.06); mean Merle d'Aubigné-Postel score from 14.55 (SD 1.74) to 16 (SD 1.6; p = 0.01); and mean mHHS from 60.6 (SD 18.06) to 81 (SD 6.63; p = 0.021). The EQ-5D-5L also showed significant improvements. Conclusion: FHRO associated with periacetabular procedures is a safe technique that showed improved functional, clinical, and morphological outcomes in Perthes' disease. The newly introduced simulation and planning algorithm may help to further refine the technique.


Subject(s)
Femur Head , Legg-Calve-Perthes Disease , Osteotomy , Humans , Legg-Calve-Perthes Disease/surgery , Legg-Calve-Perthes Disease/diagnostic imaging , Osteotomy/methods , Male , Female , Femur Head/diagnostic imaging , Femur Head/surgery , Child , Adolescent , Treatment Outcome , Tomography, X-Ray Computed , Magnetic Resonance Imaging , Range of Motion, Articular , Acetabulum/surgery , Acetabulum/diagnostic imaging , Retrospective Studies
8.
Bone Joint J ; 106-B(5 Supple B): 3-10, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38688494

ABSTRACT

Aims: The aim of this study was to investigate whether anterior pelvic plane-pelvic tilt (APP-PT) is associated with distinct hip pathomorphologies. We asked: is there a difference in APP-PT between young symptomatic patients being evaluated for joint preservation surgery and an asymptomatic control group? Does APP-PT vary among distinct acetabular and femoral pathomorphologies? And does APP-PT differ in symptomatic hips based on demographic factors? Methods: This was an institutional review board-approved, single-centre, retrospective, case-control, comparative study, which included 388 symptomatic hips in 357 patients who presented to our tertiary centre for joint preservation between January 2011 and December 2015. Their mean age was 26 years (SD 2; 23 to 29) and 50% were female. They were allocated to 12 different morphological subgroups. The study group was compared with a control group of 20 asymptomatic hips in 20 patients. APP-PT was assessed in all patients based on supine anteroposterior pelvic radiographs using validated HipRecon software. Values in the two groups were compared using an independent-samples t-test. Multiple regression analysis was performed to examine the influences of diagnoses and demographic factors on APP-PT. The minimal clinically important difference (MCID) for APP-PT was defined as > 1 SD. Results: There were no significant differences in APP-PT between the control group and the overall group (1.1° (SD 3.0°; -4.9° to 5.9°) vs 1.8° (SD 3.4°; -6.9° to 13.2°); p = 0.323). Acetabular retroversion and overcoverage groups showed higher mean APP-PTs compared with the control group (p = 0.001 and p = 0.014) and were the only diagnoses with a significant influence on APP-PT in the stepwise multiple regression analysis. All differences were below the MCID. The age, sex, height, weight, and BMI showed no influence on APP-PT. Conclusion: APP-PT showed no radiologically significant variation across different pathomorphologies of the hip in patients being assessed for joint-preserving surgery.


Subject(s)
Acetabulum , Humans , Female , Acetabulum/diagnostic imaging , Male , Adult , Retrospective Studies , Case-Control Studies , Young Adult , Femur/diagnostic imaging , Hip Joint/diagnostic imaging , Hip Joint/physiopathology , Radiography , Pelvic Bones/diagnostic imaging
9.
Bone Joint J ; 106-B(5 Supple B): 25-31, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38688491

ABSTRACT

Aims: The objective of this study was to present the outcomes of rotational acetabular osteotomy (RAO) over a 30-year period for osteoarthritis (OA) secondary to dysplasia of the hip in pre- or early-stage OA. Methods: Between September 1987 and December 1994, we provided treatment to 47 patients (55 hips) with RAO for the management of pre- or early-stage OA due to developmental hip dysplasia. Of those, eight patients (11 hips) with pre-OA (follow-up rate 79%) and 27 patients (32 hips) with early-stage OA (follow-up rate 78%), totalling 35 patients (43 hips) (follow-up rate 78%), were available at a minimum of 28 years after surgery. Results: In the pre-OA group, the mean Merle d'Aubigné score improved significantly from 14.5 points (SD 0.7) preoperatively to 17.4 points at final follow-up (SD 1.2; p = 0.004) and in the early-stage group, the mean score did not improve significantly from 14.0 (SD 0.3) to 14.6 (SD 2.4; p = 0.280). Radiologically, the centre-edge angle, acetabular roof angle, and head lateralization index were significantly improved postoperatively in both groups. Radiological progression of OA was observed in two patients (two hips) in the pre-OA group and 17 patients (18 hips) in the early-stage group. Kaplan-Meier survival analysis, with radiological progression of OA as the primary outcome, projected a 30-year survival rate of 81.8% (95% confidence interval (CI) 0.59 to 1.00) for the pre-OA group and 42.2% (95% CI 0.244 to 0.600) for the early-stage group. In all cases, the overall survival rate stood at 51.5% (95% CI 0.365 to 0.674) over a 30-year period, and when the endpoint was conversion to total hip arthroplasty, the survival rate was 74.0% (95% CI 0.608 to 0.873). Conclusion: For younger patients with pre-OA, joint preservation of over 30 years can be expected after RAO.


Subject(s)
Acetabulum , Osteoarthritis, Hip , Osteotomy , Humans , Osteotomy/methods , Osteoarthritis, Hip/surgery , Osteoarthritis, Hip/etiology , Female , Follow-Up Studies , Acetabulum/surgery , Acetabulum/diagnostic imaging , Male , Adult , Treatment Outcome , Middle Aged , Radiography , Hip Dislocation, Congenital/surgery , Hip Dislocation, Congenital/complications , Hip Dislocation, Congenital/diagnostic imaging , Young Adult , Adolescent
10.
Bone Joint J ; 106-B(5 Supple B): 82-88, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38688509

ABSTRACT

Aims: Large bone defects resulting from osteolysis, fractures, osteomyelitis, or metastases pose significant challenges in acetabular reconstruction for total hip arthroplasty. This study aimed to evaluate the survival and radiological outcomes of an acetabular reconstruction technique in patients at high risk of reconstruction failure (i.e. periprosthetic joint infection (PJI), poor bone stock, immunosuppressed patients), referred to as Hip Reconstruction In Situ with Screws and Cement (HiRISC). This involves a polyethylene liner embedded in cement-filled bone defects reinforced with screws and/or plates for enhanced fixation. Methods: A retrospective chart review of 59 consecutive acetabular reconstructions was performed by four surgeons in a single institution from 18 October 2018 to 5 January 2023. Cases were classified based on the Paprosky classification, excluding type 1 cases (n = 26) and including types 2 or 3 for analysis (n = 33). Radiological loosening was evaluated by an orthopaedic surgeon who was not the operating surgeon, by comparing the immediate postoperative radiographs with the ones at latest follow-up. Mean follow-up was 557 days (SD 441; 31 to 1,707). Results: Out of the 33 cases analyzed, six (18.2%) constructs required revision, with four revisions due to uncontrolled infection, one for dislocation, and one for aseptic loosening. Among the 27 non-revised constructs, only one showed wider radiolucencies compared to immediate postoperative radiographs, indicating potential loosening. Patients who underwent revision (n = 6) were significantly younger and had a higher BMI compared to those with non-revised constructs (p = 0.016 and p = 0.026, respectively). Sex, race, ethnicity, American Society of Anesthesiologists grade, infection status (patients with postoperative PJI diagnosis (septic) vs patients without such diagnosis (aseptic)), and mean follow-up did not significantly differ between revised and non-revised groups. Conclusion: The HiRISC technique may serve as a feasible short-term (about one to two years) alternative in patients with large acetabular defects, particularly in cases of PJI. Longer follow-up is necessary to establish the long-term survival of this technique.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip , Bone Cements , Bone Screws , Prosthesis Failure , Reoperation , Humans , Retrospective Studies , Female , Male , Aged , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/instrumentation , Acetabulum/surgery , Acetabulum/diagnostic imaging , Middle Aged , Hip Prosthesis , Aged, 80 and over , Adult , Prosthesis-Related Infections/surgery
11.
Orthop Surg ; 16(5): 1207-1214, 2024 May.
Article in English | MEDLINE | ID: mdl-38488245

ABSTRACT

OBJECTIVE: Given the intricate challenges and potential complications associated with periacetabular osteotomy (PAO) for developmental dysplasia of the hip (DDH). Our study aimed to compare the clinical and imaging benefits and drawbacks of two surgical approaches, the modified Stoppa combined iliac spine approach and the modified Smith-Peterson approach, for treating PAO and to provide guidance for selecting clinical approaches. METHODS: A retrospective analysis of 56 patients with 62 DDHs was conducted from June 2018 to January 2022. The experimental group underwent surgery via the modified Stoppa combined iliac spine approach, while the control group underwent surgery via the modified Smith-Peterson approach for periacetabular osteotomy and internal fixation. Basic statistical parameters, including age, sex, BMI, and preoperative imaging data, were analyzed. Differences in surgical time, intraoperative blood loss, and postoperative imaging data were compared, as were differences in preoperative and postoperative imaging data between the two groups. RESULTS: There were 28 hips in the experimental group and 34 in the control group. Moreover, there was no significant difference in the basic parameters between the experimental and control groups. Before and after the operation, for the LCE angle, ACE angle, and Tonnis angle, there was no significant difference in acetabular coverage (p > 0.05). However, there were significant differences between the two groups in terms of the above four indicators before and after the operation (p < 0.05). After the operation, the experimental group exhibited significant increases in both lateral and anterior acetabular coverage of the femoral head. However, the experimental group had longer operation times and greater bleeding volumes than did the control group. Despite this, the experimental group demonstrated significant advantages in protecting the lateral femoral cutaneous nerve compared to the control group. CONCLUSION: The modified Stoppa combined iliac spine approach can be considered a practical approach for PAO and is more suitable for patients with DDH who plan to be treated by one operation than the classic modified Smith-Peterson approach for PAO.


Subject(s)
Acetabulum , Developmental Dysplasia of the Hip , Osteotomy , Humans , Retrospective Studies , Female , Osteotomy/methods , Male , Developmental Dysplasia of the Hip/surgery , Developmental Dysplasia of the Hip/diagnostic imaging , Adult , Acetabulum/surgery , Acetabulum/diagnostic imaging , Middle Aged , Young Adult , Adolescent
12.
J Orthop Trauma ; 38(6): 306-312, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38442184

ABSTRACT

OBJECTIVES: To describe the technique and results of a new sagittal plane computed tomography (CT)-based angular measure for predicting stability after posterior wall acetabular fractures (PWF). DESIGN: Retrospective review. SETTING: Academic Level II trauma center. PATIENT SELECTION CRITERIA: Fifty-eight consecutive patients with PWF (AO/OTA class 62A.1), 98% were high-energy injuries. INTERVENTION: A new sagittal CT measure of PWF based on the angle subtending the joint center, cranial and caudal fracture exits. OUTCOME MEASURES AND COMPARISONS: Hip incongruity or dislocation demonstrated using gold standard test, examination under anesthesia (EUA), or instability on static images. Prediction of hip instability using a sagittal CT angular measure based on cranial and caudal fracture exits was compared with previous axial CT measures suggestive of increased risk for instability including posterior wall size >50%, and those with cranial exit within 5.0 mm of the acetabular dome. RESULTS: There were 32 operative and 26 nonoperatively treated fractures. Thirty fractures were determined to be unstable, and 28 were stable after EUA. Measurements of >70 degrees using the sagittal CT angular measure predicted instability in 28 of 28 patients, and ≤70 degrees predicted stability in 30 of 30 patients (sensitivity 100% and specificity 100%). Prevalence of EUA confirmed instability for subgroups with PWF based on prior axial CT measures were as follows: ≥50% wall involvement (11/16; sensitivity 67% and specificity 60%; 95% CI, 45%-89%/45%-75%), fracture within 5.0 mm of dome (5/18; sensitivity 86% and specificity 73%; 95% CI, 71%-100%/59%-87%), fracture within 5.0 mm of dome and ≥50% involvement (1/9; sensitivity 89% and specificity 56%; 95% CI, 69%-100%/24%-88%). CONCLUSIONS: In a sample of 58 mostly high energy posterior wall fractures all having had an EUA, a new sagittal angular CT measurement of ≤70 degrees predicted hip stability and >70 degrees predicted instability with 100% sensitivity and specificity. LEVEL OF EVIDENCE: Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Acetabulum , Fractures, Bone , Joint Instability , Sensitivity and Specificity , Tomography, X-Ray Computed , Humans , Acetabulum/injuries , Acetabulum/diagnostic imaging , Tomography, X-Ray Computed/methods , Male , Female , Middle Aged , Adult , Joint Instability/diagnostic imaging , Joint Instability/physiopathology , Retrospective Studies , Fractures, Bone/diagnostic imaging , Aged , Young Adult , Reproducibility of Results , Aged, 80 and over , Hip Joint/diagnostic imaging , Hip Joint/physiopathology
13.
Zhongguo Gu Shang ; 37(2): 135-41, 2024 Feb 25.
Article in Chinese | MEDLINE | ID: mdl-38425063

ABSTRACT

OBJECTIVE: To evaluate the feasibility and accuracy of virtual preoperative planning and 3D-printed templates for pre-contoured plates for the treatment of posterior wall fractures of the acetabulum. METHODS: A retrospective analysis of 29 patients with posterior acetabular wall fractures treated between August 2017 and March 2021 were divided into 2 groups based on whether to use preoperative virtual planning and 3D printed template. In 3D-printing group, there were 14 patients, including 10 males and 4 females; aged from 21 to 53 years old;CT-based virtual surgical planning was done using Mimics and 3-Matic software and 3D-printed templates for pre-contoured plates were adopted. In conventional group, there were 15 patients, including 10 males and 5 females;aged from 19 to 55 years old;conventional method of intra-operative contouring to adapt the plate to the fracture region was adopted. Blood loss, surgical time, radiographic quality of reduction, and hip function were compared between groups. RESULTS: The difference in operation time and intraoperative blood loss was significant(P<0.05). Twenty-three patients were followed up from 12 to 30 months, and the fractures in both groups healed with a healing time of 3 to 6 months. At the last follow-up, the Merle d'Aubign-Postel score of the 3D printed group was lower than that of the conventional group(P<0.05), with no significant differences in walking ability, hip mobility and total score(P>0.05). In 3D printing group, 6 cases were excellent, 5 cases were good, 3 cases were fair;in conventional group, 5 cases were excellent, 5 cases were good, 4 cases were fair, 1 case was worse;no significant difference between two groups(P>0.05). CONCLUSION: Virtual preoperative planning and 3D-printed templates for pre-contoured plates can reduce operative time and the blood loss of surgery, improve the quality of reduction. This method is efficient, accurate and reliable to treat acetabular posterior wall fractures.


Subject(s)
Fractures, Bone , Hip Fractures , Spinal Fractures , Male , Female , Humans , Young Adult , Adult , Middle Aged , Fracture Fixation, Internal/methods , Retrospective Studies , Hip Fractures/surgery , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Acetabulum/diagnostic imaging , Acetabulum/surgery , Acetabulum/injuries , Printing, Three-Dimensional , Bone Plates , Treatment Outcome
14.
Pediatrics ; 153(4)2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38501191

ABSTRACT

OBJECTIVES: To examine radiologic outcomes at skeletal maturity of sonographically normal, immature, mildly, and severely dysplastic newborn hips. METHODS: During 1988 to 1990, 11 925 newborns were enrolled in a randomized controlled trial examining screening strategies for developmental hip dysplasia. In total, 4469 were invited to clinical and radiologic follow-up 18 years later, of which 1735 had received neonatal ultrasound. Radiographic markers for dysplasia in left adult hips included the center-edge (CE) angle. RESULTS: At follow-up, 984 of 1735 (56.7%) with newborn ultrasound met, of which 966 (614 females) had valid radiographs and were thus included. For females, 34 (10.2%) and 1 (0.3%) of the 332 sonographically normal left neonatal hips were judged borderline (20°≤ CE <25°) or dysplastic (CE <20°) at skeletal maturity respectively. Corresponding numbers were 36 (19.7%) and 3 (1.6%) of the 183 immature, 12 (15.6%) and 2 (2.6%) of the 77 mildly dysplastic, and 3 (13.6%) and 3 (13.6%) of the 22 severely dysplastic neonatal left hips (P ≤ .001). In males, no associations were found. In females, adult joint hypermobility was associated with sonographic neonatal hip instability (P = .046), as well as with adult acetabular dysplasia (P = .024). CONCLUSIONS: Significant associations between neonatal hip phenotypes and adult dysplasia were revealed in females. This indicates the possibility of different mechanisms affecting the course of developmental dysplasia of the hip for females and males, prompting consideration of prolonged clinical and radiologic follow-up for females with dysplastic neonatal hips. Results in males are limited by low numbers of dysplastic hips. The significance of joint hypermobility warrants further investigation.


Subject(s)
Hip Dislocation, Congenital , Hip Dislocation , Joint Instability , Male , Female , Humans , Infant, Newborn , Young Adult , Hip Dislocation/diagnostic imaging , Hip Dislocation, Congenital/diagnostic imaging , Radiography , Ultrasonography , Acetabulum/diagnostic imaging , Hip Joint/diagnostic imaging , Retrospective Studies
15.
Bone Joint J ; 106-B(4): 336-343, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38555935

ABSTRACT

Aims: Periacetabular osteotomy (PAO) is widely recognized as a demanding surgical procedure for acetabular reorientation. Reports about the learning curve have primarily focused on complication rates during the initial learning phase. Therefore, our aim was to assess the PAO learning curve from an analytical perspective by determining the number of PAOs required for the duration of surgery to plateau and the accuracy to improve. Methods: The study included 118 consecutive PAOs in 106 patients. Of these, 28 were male (23.7%) and 90 were female (76.3%). The primary endpoint was surgical time. Secondary outcome measures included radiological parameters. Cumulative summation analysis was used to determine changes in surgical duration. A multivariate linear regression model was used to identify independent factors influencing surgical time. Results: The learning curve in this series was 26 PAOs in a period of six months. After 26 PAO procedures, a significant drop in surgical time was observed and a plateau was also achieved. The mean duration of surgery during the learning curve was 103.8 minutes (SD 33.2), and 69.7 minutes (SD 18.6) thereafter (p < 0.001). Radiological correction of acetabular retroversion showed a significant improvement after having performed a total of 93 PAOs, including anteverting PAOs on 35 hips with a retroverted acetabular morphology (p = 0.005). Several factors were identified as independent variables influencing duration of surgery, including patient weight (ß = 0.5 (95% confidence interval (CI) 0.2 to 0.7); p < 0.001), learning curve procedure phase of 26 procedures (ß = 34.0 (95% CI 24.3 to 43.8); p < 0.001), and the degree of lateral correction expressed as the change in the lateral centre-edge angle (ß = 0.7 (95% CI 0.001 to 1.3); p = 0.048). Conclusion: The learning curve for PAO surgery requires extensive surgical training at a high-volume centre, with a minimum of 50 PAOs per surgeon per year. This study defined a cut-off value of 26 PAO procedures, after which a significant drop in surgical duration occurred. Furthermore, it was observed that a retroverted morphology of the acetabulum required a greater number of procedures to acquire proficiency in consistently eliminating the crossover sign. These findings are relevant for fellows and fellowship programme directors in establishing the extent of training required to impart competence in PAO.


Subject(s)
Hip Dislocation , Hip Joint , Humans , Male , Female , Hip Joint/surgery , Hip Dislocation/surgery , Learning Curve , Retrospective Studies , Treatment Outcome , Acetabulum/diagnostic imaging , Acetabulum/surgery , Osteotomy/methods
16.
Bone Joint J ; 106-B(4): 359-364, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38555950

ABSTRACT

Aims: To investigate the extent of bone development around the scaffold of custom triflange acetabular components (CTACs) over time. Methods: We performed a single-centre historical prospective cohort study, including all patients with revision THA using the aMace CTAC between January 2017 and March 2021. A total of 18 patients (18 CTACs) were included. Models of the hemipelvis and the scaffold component of the CTACs were created by segmentation of CT scans. The CT scans were performed immediately postoperatively and at least one year after surgery. The amount of bone in contact with the scaffold was analyzed at both times, and the difference was calculated. Results: The mean time between the implantation and the second CT scan was two years (1 to 5). The mean age of the patients during CTAC implantation was 75 years (60 to 92). The mean scaffold-bone contact area increased from 16% (SD 12.6) to 28% (SD 11.9). The mean scaffold-bone distance decreased from a mean of 6.5 mm (SD 2.0) to 5.5 mm (SD 1.6). None of the CTACs were revised or radiologically loose. Conclusion: There was a statistically significant increase of scaffold-bone contact area over time, but the total contact area of the scaffold in relation to the acetabular bone remained relatively low. As all implants remained well fixed, the question remains to what extend the scaffold contributes to the observed stability, in relation to the screws. A future design implication might be an elimination of the bulky scaffold component. This design modification would reduce production costs and may optimize the primary fit of the implant.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Aged , Prospective Studies , Reoperation , Prosthesis Design , Acetabulum/diagnostic imaging , Acetabulum/surgery , Prosthesis Failure , Follow-Up Studies
17.
BMC Musculoskelet Disord ; 25(1): 242, 2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38539141

ABSTRACT

PURPOSE: The results after acetabular fracture are primarily related to the quality of articular reduction. Using the AO large femoral distractor, incarcerated fragments can be easily removed, and marginally impacted fragments can be elevated under direct visualization without further re-dislocating the joint. The current study aimed to evaluate our early results of using the AO large femoral distractor as an assisting tool during ORIF of acetabular fractures associated with marginal impaction or intraarticular incarcerated fragments. METHODS: Eighteen patients were included in this retrospective case series study diagnosed with an acetabular fracture associated with either marginal impaction injury or an intraarticular incarcerated fragment. On a usual operative table, all patients were operated upon in a prone position through the Kocher Langenbeck approach. The AO large femoral distractor was used to facilitate hip joint distraction. Postoperative fracture reduction and joint clearance were assessed in the immediate postoperative CT scans. RESULTS: The average age of the patients was 30 ± 8.2 years; 13 (72.2%) were males. All cases had a posterior wall fracture, and it was associated with transverse fractures, posterior column fractures, and T-type fractures in five (27.8%), two (11.1%), and one (5.6%) patients, respectively. Intraarticular incarcerated fragments were present in 13 (72.2%) cases and marginal impaction in five (27.8%). Fracture reduction measured on the postoperative CT scans showed an anatomical reduction in 14 (77.8%) patients, imperfect in four (22.2%), and complete clearance of the hip joint of any incarcerated fragments. CONCLUSION: The use of the AO large femoral distractor is a reliable and reproducible technique that can be applied to assist in the removal of incarcerated intraarticular fragments and to ease the reduction of marginally impacted injuries associated with acetabular fractures.


Subject(s)
Fractures, Bone , Hip Fractures , Spinal Fractures , Adult , Female , Humans , Male , Young Adult , Acetabulum/diagnostic imaging , Acetabulum/surgery , Acetabulum/injuries , Fracture Fixation, Internal/methods , Fractures, Bone/complications , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Hip Fractures/complications , Hip Joint/diagnostic imaging , Hip Joint/surgery , Retrospective Studies , Spinal Fractures/complications
18.
J Pediatr Orthop ; 44(5): e433-e438, 2024.
Article in English | MEDLINE | ID: mdl-38454629

ABSTRACT

BACKGROUND: Traumatic, posterior hip dislocations in the pediatric population are typically managed by closed reduction to achieve a concentric hip joint. The presence of an acetabular "fleck" sign, despite concentric reduction, has been shown to signify significant hip pathology. The purpose of this study was to evaluate the outcomes of open labral repair through a surgical hip dislocation (SHD) in a consecutive series of patients with an acetabular "fleck" sign associated with a traumatic hip dislocation/subluxation. METHODS: A retrospective review of patients between 2008 and 2022 who presented to a single, level 1 pediatric trauma center with a traumatic posterior hip dislocation/subluxation was performed. Patients were included if they had an acetabular "fleck" sign on advanced imaging and underwent open labral repair through SHD. Medical records were reviewed for sex, age, laterality, mechanism of injury (MOI), and associated orthopaedic injuries. The modified Harris hip score (mHHS) was utilized as the primary clinical outcomes measure. Patients were assessed for the presence of heterotopic ossification (HO) and complications, including implant issues, infection, avascular necrosis (AVN), and post-traumatic dysplasia. RESULTS: Twenty-nine patients (23 male, average age: 13.0±2.7 y; range: 5.2 to 17.3) were identified. Eighteen injuries were sports related, 9 caused by motor vehicle accidents, and 1 pedestrian struck. All patients were found to have an acetabular "fleck" sign on CT (26 patients) or MRI (5 patients). Associated injuries included: femoral head fracture (n=6), pelvic ring injury (n=3), ipsilateral femur fracture (n=2), and ipsilateral PCL avulsion (n=1). At the latest follow-up (2.2±1.4 y), all patients had returned to preinjury activity/sport. Three patients developed asymptomatic, grade 1 HO in the greater trochanter region. There was no incidence of AVN. One patient developed post-traumatic acetabular dysplasia due to early triradiate closure. mHHS scores showed excellent outcomes (n=21, 94.9±7.4, range: 81 to 100.1). CONCLUSIONS: The acetabular "fleck" sign indicates a consistent pattern of osteochondral avulsion of the posterior/superior labrum. Restoring native hip anatomy and stability is likely to improve outcomes. SHD with open labral repair in these patients produces excellent clinical outcomes, with no reported cases of AVN. LEVEL OF EVIDENCE: Level IV-therapeutic.


Subject(s)
Femoral Fractures , Hip Dislocation , Humans , Male , Child , Adolescent , Hip Dislocation/diagnostic imaging , Hip Dislocation/surgery , Acetabulum/diagnostic imaging , Acetabulum/surgery , Acetabulum/injuries , Hip Joint/diagnostic imaging , Hip Joint/surgery , Retrospective Studies , Treatment Outcome
19.
Bone Joint J ; 106-B(3 Supple A): 104-109, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38425294

ABSTRACT

Aims: Femoral component anteversion is an important factor in the success of total hip arthroplasty (THA). This retrospective study aimed to investigate the accuracy of femoral component anteversion with the Mako THA system and software using the Exeter cemented femoral component, compared to the Accolade II cementless femoral component. Methods: We reviewed the data of 30 hips from 24 patients who underwent THA using the posterior approach with Exeter femoral components, and 30 hips from 24 patients with Accolade II components. Both groups did not differ significantly in age, sex, BMI, bone quality, or disease. Two weeks postoperatively, CT images were obtained to measure acetabular and femoral component anteversion. Results: The mean difference in femoral component anteversion between intraoperative and postoperative CT measurements (system accuracy of component anteversion) was 0.8° (SD 1.8°) in the Exeter group and 2.1° (SD 2.3°) in the Accolade II group, respectively (p = 0.020). The mean difference in anteversion between the plan and the postoperative CT measurements (clinical accuracy of femoral component anteversion) was 1.2° (SD 3.6°) in the Exeter group, and 4.2° (SD 3.9°) in the Accolade II group (p = 0.003). No significant differences were found in acetabular component inclination and anteversion; however, the clinical accuracy of combined anteversion was significantly better in the Exeter group (0.6° (SD 3.9°)) than the Accolade II group (3.6° (SD 4.1°)). Conclusion: The Mako THA system and software helps surgeons control the femoral component anteversion to achieve the target angle of insertion. The Exeter femoral component, inserted using Mako THA system, showed greater precision for femoral component and combined component anteversion than the Accolade II component.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Robotic Surgical Procedures , Humans , Acetabulum/diagnostic imaging , Acetabulum/surgery , Arthroplasty, Replacement, Hip/methods , Retrospective Studies , Tomography, X-Ray Computed , Male , Female
20.
Article in English | MEDLINE | ID: mdl-38441133

ABSTRACT

We present three cases of posterior wall acetabulum fractures occurring in pediatric patients with open triradiate cartilage for whom preoperative magnetic resonance imaging was obtained and open reduction and internal fixation was done. All patients had excellent outcomes at an average of 68-week follow-up. Failure to adequately recognize the severity of pediatric acetabulum fractures can lead to detrimental long-term sequelae in acetabular development when treated nonsurgically. Management of this rare injury is not well reported in the literature. We highlight the utility of MRI in evaluating potential nonosseous injury and examining the articular surface to guide surgical management.


Subject(s)
Hip Fractures , Spinal Fractures , Humans , Child , Acetabulum/diagnostic imaging , Acetabulum/surgery , Cartilage , Magnetic Resonance Imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...