1.
Clin Oral Investig ; 28(6): 312, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38748326

ABSTRACT

OBJECTIVES: Material chemistry and workflow variables associated with the fabrication of dental devices may affect the biocompatibility of the dental devices. The purpose of this study was to compare digital and conventional workflow procedures in the manufacturing of acrylic-based occlusal devices by assessing the cytotoxic potential of leakage products. METHODS: Specimens were manufactured by 3D printing (stereolithography and digital light processing), milling, and autopolymerization. Print specimens were also subjected to different post-curing methods. To assess biocompatibility, a human tongue epithelial cell line was exposed to material-based extracts. Cell viability was measured by MTT assay while Western blot assessed the expression level of selected cytoprotective proteins. RESULTS: Extracts from the Splint 2.0 material printed with DLP technology and post-cured with the Asiga Flash showed the clearest loss of cell viability. The milled and autopolymerized materials also showed a significant reduction in cell viability. However, by storing the autopolymerized material in dH2O for 12 h, no significant viability loss was observed. Increased levels of cytoprotective proteins were seen in cells exposed to extracts from the print materials and the autopolymerized material. Similarly to the effect on viability loss, storing the autopolymerized material in dH2O for 12 h reduced this effect. CONCLUSIONS/CLINICAL RELEVANCE: Based on the biocompatibility assessments, clinical outcomes of acrylic-based occlusal device materials may be affected by the choice of manufacturing technique and workflow procedures.


Subject(s)
Biocompatible Materials , Cell Survival , Materials Testing , Printing, Three-Dimensional , Humans , Biocompatible Materials/chemistry , In Vitro Techniques , Acrylic Resins/chemistry , Cell Line , Blotting, Western
2.
BMC Oral Health ; 24(1): 557, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38735940

ABSTRACT

BACKGROUND: Dental resin-based composites are widely recognized for their aesthetic appeal and adhesive properties, which make them integral to modern restorative dentistry. Despite their advantages, adhesion and biomechanical performance challenges persist, necessitating innovative strategies for improvement. This study addressed the challenges associated with adhesion and biomechanical properties in dental resin-based composites by employing molecular docking and dynamics simulation. METHODS: Molecular docking assesses the binding energies and provides valuable insights into the interactions between monomers, fillers, and coupling agents. This investigation prioritizes SiO2 and TRIS, considering their consistent influence. Molecular dynamics simulations, executed with the Forcite module and COMPASS II force field, extend the analysis to the mechanical properties of dental composite complexes. The simulations encompassed energy minimization, controlled NVT and NPT ensemble simulations, and equilibration stages. Notably, the molecular dynamics simulations spanned a duration of 50 ns. RESULTS: SiO2 and TRIS consistently emerged as influential components, showcasing their versatility in promoting solid interactions. A correlation matrix underscores the significant roles of van der Waals and desolvation energies in determining the overall binding energy. Molecular dynamics simulations provide in-depth insights into the mechanical properties of dental composite complexes. HEMA-SiO2-TRIS excelled in stiffness, BisGMA-SiO2-TRIS prevailed in terms of flexural strength, and EBPADMA-SiO2-TRIS offered a balanced combination of mechanical properties. CONCLUSION: These findings provide valuable insights into optimizing dental composites tailored to diverse clinical requirements. While EBPADMA-SiO2-TRIS demonstrates distinct strengths, this study emphasizes the need for further research. Future investigations should validate the computational findings experimentally and assess the material's response to dynamic environmental factors.


Subject(s)
Biocompatible Materials , Composite Resins , Molecular Docking Simulation , Molecular Dynamics Simulation , Silicon Dioxide , Composite Resins/chemistry , Silicon Dioxide/chemistry , Biocompatible Materials/chemistry , Dental Materials/chemistry , Methacrylates/chemistry , Polyurethanes/chemistry , Polymethacrylic Acids/chemistry , Polyethylene Glycols/chemistry , Acrylic Resins/chemistry
3.
Clin Exp Dent Res ; 10(3): e888, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38712436

ABSTRACT

OBJECTIVE: To evaluate the effects of metal primer II (MP II) on the shear bond strength (SBS) of orthodontic brackets bonded to teeth and bis-acryl composite provisional material (Bis-Acryl). MATERIAL AND METHODS: Twenty extracted human premolars specimens and 20 premolar shaped Bis-Acryl specimens were obtained and randomly divided into two surface groups. The first group consisted of human premolars (T) bonded to brackets in the conventional way while in the second (T-MP) MP II was applied on the bracket base before bonding. Similarly, one group of provisional material (PM) was prepared according to conventional treatment and another with the application of MP-II metal bonder (PM-MP). In all cases Ortho-brackets (Victory Series, 3 M) were bonded employing Transbond XT resin cement. Then the brackets were debonded under shear and the results were statistically analyzed by two-way analysis of variance and Holm Sidak at α = .05. The debonded surfaces of all specimens were examined by light microscopy and the Adhesive Remnant Index (ARI) was recorded. RESULTS: The SBS results exhibited significant differences er (p < .001). For both the T and TM the application of MP-II increased the SBS compared to respective control groups (p < .001). The T-C group was found inferior compared to PM-C (p < .001) and the same is true for the comparison between T-MP and PM-MP (p < .001). ARI indexes demonstrated that the tooth groups were characterized by a predominantly adhesive failure at the resin-dentin interface. In contrast, the control group for provisional crowns (PM-C) showed a predominantly cohesive failure mode, which moved to predominantly adhesive after the application of MP II. CONCLUSION: The application of MP II enhances the SBS on both, human enamel and provisional crown materials.


Subject(s)
Dental Bonding , Orthodontic Brackets , Resin Cements , Shear Strength , Surface Properties , Humans , Resin Cements/chemistry , Dental Bonding/methods , Bicuspid , Dental Stress Analysis , Materials Testing , Acrylic Resins/chemistry , Composite Resins/chemistry , Acid Etching, Dental/methods , Dental Enamel/chemistry , Dental Enamel/drug effects
4.
Fr J Urol ; 34(2): 102585, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38717460

ABSTRACT

INTRODUCTION: The aim was to compare the efficacy of polyacrylate polyalcohol copolymer (PPC) injections and dextranomer/hyaluronic acid (Dx/Ha) injections for the endoscopic treatment of vesicoureteral reflux in children. MATERIAL: This retrospective cohort study included 189 young patients who had endoscopic treatment for vesicoureteral reflux from January 2012 to December 2019 in our center. Among them, 101 had PCC injections and 88 had Dx/Ha injections. Indications for treatment were vesicoureteral reflux with breakthrough urinary tract infection or vesicoureteral reflux with renal scarring on dimercaptosuccinic acid (DMSA) renal scan. Endoscopic injection was performed under the ureteral meatus. Early complications, recurrence of febrile urinary tract infection and vesicoureteral reflux after endoscopic injection, ureteral obstruction and reintervention were evaluated and compared between groups. RESULTS: Endoscopic treatment was successful in 90.1% of patients who had PPC injection and in 82% of patients who had Dx/Ha injection. Four patients presented a chronic ureteral obstruction after PPC injection, one with a complete loss of function of the dilated kidney. One patient in the Dx/Ha group presented a postoperative ureteral dilatation after 2 injections. CONCLUSION: Despite a similar success rate after PPC and Dx/Ha injections for endoscopic treatment of VUR, there may be a greater risk of postoperative ureteral obstruction after PPC injections. The benefit of using PPC to prevent febrile UTI and renal scarring in children with low-grade VUR does not seem to outweigh the risk of chronic ureteral obstruction.


Subject(s)
Dextrans , Hyaluronic Acid , Ureteral Obstruction , Vesico-Ureteral Reflux , Humans , Vesico-Ureteral Reflux/therapy , Retrospective Studies , Hyaluronic Acid/administration & dosage , Hyaluronic Acid/therapeutic use , Hyaluronic Acid/adverse effects , Female , Male , Dextrans/therapeutic use , Dextrans/administration & dosage , Dextrans/adverse effects , Child, Preschool , Treatment Outcome , Infant , Acrylic Resins/therapeutic use , Acrylic Resins/administration & dosage , Child , Injections , Cohort Studies , Ureteroscopy/adverse effects
5.
J Orthop Surg Res ; 19(1): 274, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38698396

ABSTRACT

OBJECTIVE: There are few effective osteoarthritis (OA) therapies. A novel injectable polyacrylamide hydrogel (iPAAG) previously demonstrated efficacy and safety up to week 26 in an open-label study of knee OA. Here we report longer-term effectiveness and safety data. METHODS: This multi-centre, open-label study included patients with symptomatic and radiographic knee OA. Primary outcome was WOMAC pain (0-100 scale) at 13 weeks, and patients continued to 26 weeks before entering a further 26-week extension phase. Secondary efficacy outcomes included WOMAC stiffness and function subscales, Patient Global Assessment (PGA) and proportion of OMERACT-OARSI responders. Safety outcomes were adverse events (AEs). RESULTS: 49 participants (31 women, mean age 70) received an ultrasound-guided, intra-articular injection of 6 ml iPAAG; 46 completed the extension phase to 52 weeks. There was a significant reduction in the WOMAC pain score from baseline to 52 weeks (- 17.7 points (95% CI - 23.1; - 12.4); p < 0.0001). Similar sustained improvements were observed for WOMAC stiffness (11.0 points; 95% CI - 17.0; - 4.9), physical function (18.0 points; 95% CI - 19.1; - 10.6), and PGA (16.3 points; 95% CI - 23.1; - 9.4). At 52 weeks 62.2% of patients were OMERACT-OARSI responders. From 26 to 52 weeks, 8 adverse effects (AE), including 1 serious AE (cerebrovascular accident) were reported in 5 subjects. None of the new adverse events were thought to be device related. CONCLUSION: This open-label study suggests persistent benefits and safety of iPAAG through 52 weeks after a single injection. TRIAL REGISTRATION: Clinicaltrials.gov NCT04179552.


Subject(s)
Acrylic Resins , Osteoarthritis, Knee , Humans , Female , Osteoarthritis, Knee/drug therapy , Acrylic Resins/administration & dosage , Male , Aged , Middle Aged , Treatment Outcome , Follow-Up Studies , Injections, Intra-Articular , Time Factors , Hydrogels/administration & dosage , Aged, 80 and over
6.
J Appl Oral Sci ; 32: e20230397, 2024.
Article in English | MEDLINE | ID: mdl-38695444

ABSTRACT

Specific products containing natural resources can contribute to the innovation of complete denture hygiene. OBJECTIVE: To conduct an in vitro evaluation of experimental dentifrices containing essential oils of Bowdichia virgilioides Kunth (BvK), Copaifera officinalis (Co), Eucalyptus citriodora (Ec), Melaleuca alternifolia (Ma) and Pinus strobus (Ps) at 1%. METHODOLOGY: The variables evaluated were organoleptic and physicochemical characteristics, abrasiveness (mechanical brushing machine) simulating 2.5 years, and microbial load (Colony Forming Units - CFU/mL), metabolic activity (XTT assay) and cell viability (Live/Dead® BacLight™ kit) of the multispecies biofilm (Streptococcus mutans: Sm, Staphylococcus aureus: Sa, Candida albicans: Ca and Candida glabrata: Cg). Specimens of heat-polymerized acrylic resins (n=256) (n=96 specimens for abrasiveness, n=72 for microbial load count, n=72 for biofilm metabolic activity, n=16 for cell viability and total biofilm quantification) with formed biofilm were divided into eight groups for manual brushing (20 seconds) with a dental brush and distilled water (NC: negative control), Trihydral (PC: positive control), placebo (Pl), BvK, Co, Ec, Ma or Ps. After brushing, the specimens were washed with PBS and immersed in Letheen Broth medium, and the suspension was sown in solid specific medium. The organoleptic characteristics were presented by descriptive analysis. The values of density, pH, consistency and viscosity were presented in a table. The data were analyzed with the Wald test in a generalized linear model, followed by the Kruskal-Wallis test, Dunn's test (mass change) and the Bonferroni test (UFC and XTT). The Wald test in Generalized Estimating Equations and the Bonferroni test were used to analyze cell viability. RESULTS: All dentifrices showed stable organoleptic characteristics and adequate physicochemical properties. CN, Ec, Ps, Pl and PC showed low abrasiveness. There was a significant difference between the groups (p<0.001) for microbial load, metabolic activity and biofilm viability. CONCLUSIONS: It was concluded that the BvK, Ec and Ps dentifrices are useful for cleaning complete dentures, as they have antimicrobial activity against biofilm. The dentifrices containing Bowdichia virgilioides Kunth showed medium abrasiveness and should be used with caution.


Subject(s)
Biofilms , Dentifrices , Denture, Complete , Materials Testing , Oils, Volatile , Biofilms/drug effects , Dentifrices/pharmacology , Dentifrices/chemistry , Oils, Volatile/pharmacology , Oils, Volatile/chemistry , Denture, Complete/microbiology , Time Factors , Reproducibility of Results , Toothbrushing , Colony Count, Microbial , Staphylococcus aureus/drug effects , Statistics, Nonparametric , Streptococcus mutans/drug effects , Analysis of Variance , Microbial Viability/drug effects , Candida albicans/drug effects , Reference Values , Acrylic Resins/chemistry , Acrylic Resins/pharmacology
7.
Artif Cells Nanomed Biotechnol ; 52(1): 270-277, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38696132

ABSTRACT

Spherical gold/polyacrylic acid (Au/PAA) polymer-inorganic Janus nanoparticles (JNPs) with simultaneous therapeutic and targeting functions were fabricated. The obtained Au/PAA JNPs were further selectively functionalized with folic acid (FA) and thiol PEG amine (SH-PEG-NH2) on Au sides to provide superior biocompatibility and active targeting, while the other PAA sides were loaded with 5-aminolevulinic acid (5-ALA) to serve as a photosensitizer (PS) for photodynamic therapeutic (PDT) effects on MCF-7 cancer cells. The PS loading of 5-ALA was found to be 83% with an average hydrodynamic size and z-potential of 146 ± 0.8 nm and -6.40 mV respectively for FA-Au/PAA-ALA JNPs. The in vitro PDT study of the JNPs on MCF-7 breast cancer cells under 636 nm laser irradiation indicated the cell viability of 24.7% ± 0.5 for FA-Au/PAA-ALA JNPs at the IC50 value of 0.125 mM. In this regard, the actively targeted FA-Au/PAA-ALA JNPs treatment holds great potential for tumour therapy with high cancer cell-killing efficacy.


Subject(s)
Aminolevulinic Acid , Breast Neoplasms , Gold , Photochemotherapy , Photosensitizing Agents , Humans , MCF-7 Cells , Breast Neoplasms/drug therapy , Breast Neoplasms/pathology , Breast Neoplasms/metabolism , Aminolevulinic Acid/chemistry , Aminolevulinic Acid/pharmacology , Gold/chemistry , Gold/pharmacology , Photosensitizing Agents/chemistry , Photosensitizing Agents/pharmacology , Nanoparticles/chemistry , Acrylic Resins/chemistry , Female , Folic Acid/chemistry , Cell Survival/drug effects
8.
J Contemp Dent Pract ; 25(3): 245-249, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38690698

ABSTRACT

AIM: The aim of the study is to determine the difference in the shear bond strengths to dentin among dental composite (Filtek Z350®, 3M), compomer (Dyract Flow®, Dentsply) and Giomer (Beautifil®, Shofu) with 3MTM Single BondTM Universal Adhesive (SBU) (7th generation, self-etch, single solution adhesive) and AdperTM Single Bond 2 Adhesive (ASB) (5th generation, total-etch, two solution adhesive). MATERIALS AND METHODS: Sixty extracted human permanent teeth were collected, cleansed of debris, and placed in distilled water. The samples were segregated into two groups depicting the two bonding agents-AdperTM (ASB) and 3MTM Single Bond Universal (SBU) and sub-grouped into three groups depicting the three restorative materials (Composite, Giomer, and Compomer) used. Groups were respresented as follows: Group I-ASB + Composite; Group II-ASB + Giomer; Group III-ASB + Compomer; Group IV-SBU + Giomer; Group V-SBU + Compomer; Group VI-SBU + Composite. After applying the bonding agent as per the manufacturer's instructions, following which the restorative material was placed. A Universal Testing Machine (Instron 3366, UK) was employed to estimate the shear bond strength of the individual restorative material and shear bond strengths were calculated. RESULTS: Composite bonded with SBU (group VI) displayed the greatest shear strength (11.16 ± 4.22 MPa). Moreover, Giomers and flowable compomers displayed better bond strengths with ASB compared with their SBU-bonded counterparts. CONCLUSION: These results mark the importance of careful material selection in clinical practice and the bonding agent used to achieve optimal bond strength and enhance the clinical longevity and durability of dental restorations. CLINICAL SIGNIFICANCE: From a clinical perspective, to avoid a compressive or a shear failure, it would be preferrable to use a direct composite restorative material with SBU (Single bond universal adhesive, 7th generation) to achieve maximum bond strength. How to cite this article: Kuchibhotla N, Sathyamoorthy H, Balakrishnan S, et al. Effect of Bonding Agents on the Shear Bond Strength of Tooth-colored Restorative Materials to Dentin: An In Vitro Study. J Contemp Dent Pract 2024;25(3):245-249.


Subject(s)
Compomers , Composite Resins , Dental Bonding , Dental Stress Analysis , Dentin-Bonding Agents , Dentin , Shear Strength , Composite Resins/chemistry , Humans , Dental Bonding/methods , Dentin-Bonding Agents/chemistry , In Vitro Techniques , Compomers/chemistry , Bisphenol A-Glycidyl Methacrylate , Dental Restoration, Permanent/methods , Materials Testing , Glass Ionomer Cements/chemistry , Dental Materials/chemistry , Acrylic Resins/chemistry
9.
J Contemp Dent Pract ; 25(3): 241-244, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38690697

ABSTRACT

AIM: The current study was designed to assess the linear dimensional changes and adaptability of two heat-cured denture base resins using various cooling methods. MATERIALS AND METHODS: To prepare a total of 90 acrylic resin samples (45 acrylic resin samples for each material), four rectangular stainless-steel plates measuring 25 × 25 × 10 mm were fabricated. For both groups, the material was put into the mold at the dough stage. Group I - SR Triplex Hot Heat Cure acrylic; group II - DPI Heat Cure acrylic. Both groups used the same curing procedure. One of the following three techniques was used to cool the material (15 samples from each material) once the curing cycle was finished: (A) water bath, (b) quenching, and (C) air. A traveling microscope was used to measure the distance between the markings on the acrylic samples. The data was recorded and statistically analyzed. RESULTS: In SR Triplex Hot heat cure acrylic material, the maximum linear dimensional changes were found in the quenching technique (0.242 ± 0.05), followed by the air technique (0.168 ± 0.11) and the least was found in the water bath technique (0.146 ± 0.01). In DPI Heat Cure acrylic material, the maximum linear dimensional changes were found in the quenching technique (0.284 ± 0.09), followed by the air technique (0.172 ± 0.18) and the least was found in the water bath technique (0.158 ± 0.10). There was a statistically significant difference found between these three cooling techniques. On comparison of adaptability, the water bath technique, the marginal gap SR Triplex Hot was 0.012 ± 0.02 and DPI Heat Cure was 0.013 ± 0.02. In the quenching technique, the marginal gap SR Triplex Hot was 0.019 ± 0.04 and DPI Heat Cure was 0.016 ± 0.04. In the air technique, the marginal gap SR Triplex Hot was 0.017 ± 0.01 and DPI Heat Cure was 0.019 ± 0.01. CONCLUSION: The present study concluded that among the different cooling methods, the water bath technique had the least linear dimensional change, followed by the air and quenching techniques. When comparing the materials, DPI Heat Cure acrylic resin showed a greater linear dimensional change than SR Triplex Hot heat cure acrylic resin. CLINICAL SIGNIFICANCE: During polymerization, heat-cured acrylic resins experience dimensional changes. Shrinkage and expansion are dimensional changes that occur in heat-cured acrylic resins and have an impact on the occlusal relationship and denture fit. However, the denture base's material qualities and the different temperature variations it experiences during production may have an impact on this. How to cite this article: Kannaiyan K, Rathod A, Bhushan P, et al. Assessment of Adaptability and Linear Dimensional Changes of Two Heat Cure Denture Base Resin with Different Cooling Techniques: An In Vitro Study. J Contemp Dent Pract 2024;25(3):241-244.


Subject(s)
Acrylic Resins , Denture Bases , Hot Temperature , Materials Testing , Acrylic Resins/chemistry , In Vitro Techniques , Cold Temperature , Dental Materials/chemistry
10.
Can Vet J ; 65(5): 443-450, 2024 May.
Article in English | MEDLINE | ID: mdl-38694731

ABSTRACT

Linguoverted mandibular canine teeth (LMC) is a common malocclusion in dogs. Several inclined bite-plane techniques using acrylic resin have been introduced to correct LMC in dogs. Although these techniques have suggested modifications to overcome shortcomings, there are still limitations; e.g., high technical sensitivity, as the viscous acrylic resin must still be fabricated in the oral cavity. The authors developed a novel method for small-breed dogs that uses a doughy acrylic resin form to achieve an easy intraoral design and extraoral fabrication. Eight small-breed dogs were presented to evaluate and treat malocclusion causing palatal trauma. First, a Class-1 malocclusion with linguoversion of the mandibular canine teeth (6 dogs with unilateral LMC and 2 dogs with bilateral) was diagnosed based on oral examination. Dogs were treated with the new method using a doughy acrylic resin form for 6 to 7 wk and had posttreatment follow-up 1 y after the procedure. All treated canine teeth were in correct positions 1 y after the appliances were removed. Key clinical message: The authors believe that the new method using a doughy acrylic resin form could be a good alternative for veterinarians to use when treating LMC.


Un nouveau dispositif orthodontique en acrylique pour le traitement des canines mandibulaires linguoverties chez les petits chiens. Les canines mandibulaires linguoverties (LMC) sont une malocclusion courante chez le chien. Plusieurs techniques de plan de morsure incliné utilisant de la résine acrylique ont été introduites pour corriger la LMC chez le chien. Bien que ces techniques aient suggéré des modifications pour surmonter les lacunes, elles présentent encore des limites; par exemple, une sensibilité technique élevée, car la résine acrylique visqueuse doit encore être fabriquée dans la cavité buccale. Les auteurs ont développé une nouvelle méthode pour les chiens de petite race qui utilise une forme pâteuse de résine acrylique pour obtenir une conception intra-orale et une fabrication extra-orale faciles. Huit chiens de petite race ont été présentés pour évaluer et traiter une malocclusion provoquant un traumatisme palatin. Tout d'abord, une malocclusion de classe 1 avec linguoversion des canines mandibulaires (6 chiens avec LMC unilatérale et 2 chiens avec bilatérale) a été diagnostiquée sur la base d'un examen oral. Les chiens ont été traités avec la nouvelle méthode en utilisant une forme pâteuse de résine acrylique pendant 6 à 7 semaines et ont fait l'objet d'un suivi post-traitement 1 an après la procédure. Toutes les canines traitées étaient dans la bonne position un an après le retrait des appareils.Message clinique clé:Les auteurs estiment que la nouvelle méthode utilisant une forme pâteuse de résine acrylique pourrait être une bonne alternative que les vétérinaires pourraient utiliser lors du traitement du LMC.(Traduit par Dr Serge Messier).


Subject(s)
Dog Diseases , Malocclusion , Animals , Dogs , Dog Diseases/therapy , Male , Malocclusion/veterinary , Malocclusion/therapy , Female , Acrylic Resins/therapeutic use , Cuspid , Orthodontic Appliances/veterinary
11.
ACS Biomater Sci Eng ; 10(5): 3343-3354, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38695560

ABSTRACT

Moldable tissue-sealant hydrogels were developed herein by combining the yield stress fluidity of a Carbomer and in situ cross-linking of 3-arm PEG-thiol (PEG-SH) and 4-arm PEG-acrylate (PEG-AC). The Carbomer was mixed with each PEG oligomer to form two aqueous precursors: Carbomer/PEG-SH and Carbomer/PEG-AC. The two hydrogel precursors exhibited sufficient yield stress (>100 Pa) to prevent dripping from their placement on the tissue surface. Moreover, these hydrogel precursors exhibited rapid restructuring when the shear strain was repeatedly changed. These rheological properties contribute to the moldability of these hydrogel precursors. After mixing these two precursors, they were converted from yield-stress fluids to chemically cross-linked hydrogels, Carbomer/PEG hydrogel, via thiol-Michael addition. The gelation time was 5.0 and 11.2 min at 37 and 25 °C, respectively. In addition, the Carbomer/PEG hydrogels exhibited higher cellular viability than the pure Carbomer. They also showed stable adhesiveness and burst pressure resistance to various tissues, such as the skin, stomach, colon, and cecum of pigs. The hydrogels showed excellent tissue sealing in a cecum ligation and puncture model in mice and improved the survival rate due to their tissue adhesiveness and biocompatibility. The Carbomer/PEG hydrogel is a potential biocompatible tissue sealant that surgeons can mold. It was revealed that the combination of in situ cross-linkable PEG oligomers and yield stress fluid such as Carbomer is effective for developing the moldable tissue sealant without dripping of its hydrogel precursors.


Subject(s)
Hydrogels , Polyethylene Glycols , Sulfhydryl Compounds , Hydrogels/chemistry , Hydrogels/pharmacology , Polyethylene Glycols/chemistry , Animals , Mice , Sulfhydryl Compounds/chemistry , Tissue Adhesives/chemistry , Tissue Adhesives/pharmacology , Swine , Cross-Linking Reagents/chemistry , Rheology , Humans , Acrylic Resins
12.
ACS Biomater Sci Eng ; 10(5): 3489-3499, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38661561

ABSTRACT

Electronic skins have received increasing attention due to their great application potential in wearable electronics. Meanwhile, tremendous efforts are still needed for the fabrication of multifunctional composite hydrogels with complex structures for electronic skins via simple methods. In this work, a novel three-dimensional (3D) printing composite hydrogel with stretchability, conductivity, and strain-sensing ability is produced using a one-step photocuring method to achieve a dual-signal response of the electronic skin. The composite hydrogel exhibits a triple-network structure composed of silk microfibers (SMF), regenerated silk fibroin (RSF), and polyacrylamide (PAM). The establishment of triple networks is based on the electrostatic interaction between SMF and RSF, as well as the chemically cross-linked RSF and PAM. Thanks to its specific structure and components, the composite hydrogel possesses enhanced mechanical properties (elastic modulus of 140 kPa, compressive stress of 21 MPa, and compression modulus of 600 kPa) and 3D printability while retaining stretchability and flexibility. The interaction between negatively charged SMF and cations in phosphate-buffered saline endows the composite hydrogel with good conductivity and strain-sensing ability after immersion in a low-concentration (10 mM) salt solution. Moreover, the 3D printing composite hydrogel scaffold successfully realizes real-time monitoring. Therefore, the proposed hydrogel-based ionic sensor is promising for skin tissue engineering, real-time monitoring, soft robotics, and human-machine interfaces.


Subject(s)
Acrylic Resins , Electric Conductivity , Fibroins , Hydrogels , Printing, Three-Dimensional , Wearable Electronic Devices , Fibroins/chemistry , Acrylic Resins/chemistry , Hydrogels/chemistry , Humans , Bionics
13.
J Colloid Interface Sci ; 668: 335-342, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38678888

ABSTRACT

Membrane receptors perform a diverse range of cellular functions, accounting for more than half of all drug targets. The mechanical microenvironment regulates cell behaviors and phenotype. However, conventional analysis methods of membrane receptors often ignore the effects of the extracellular matrix stiffness, failing to reveal the heterogeneity of cell membrane receptors expression. Herein, we developed an in-situ surface-enhanced Raman scattering (SERS) imaging method to visualize single-cell membrane receptors on substrates with different stiffness. Two SERS substrates, Au@4-mercaptobenzonitrile@Ag@Sgc8c and Au@4-pethynylaniline@Ag@SYL3c, were employed to specifically target protein tyrosine kinase-7 (PTK7) and epithelial cell adhesion molecule (EpCAM), respectively. The polyacrylamide (PA) gels with tunable stiffness (2.5-25 kPa) were constructed to mimic extracellular matrix. The simultaneous SERS imaging of dual membrane receptors on single cancer cells on substrates with different stiffness was achieved. Our findings reveal decreased expression of PTK7 and EpCAM on cells cultured on stiffer substrates and higher migration ability of the cells. The results elucidate the heterogeneity of membrane receptors expression of cells cultured on the substrates with different stiffness. This single-cell analysis method offers an in-situ platform for investigating the impacts of extracellular matrix stiffness on the expression of membrane receptors, providing insights into the role of cell membrane receptors in cancer metastasis.


Subject(s)
Epithelial Cell Adhesion Molecule , Extracellular Matrix , Single-Cell Analysis , Spectrum Analysis, Raman , Extracellular Matrix/metabolism , Humans , Epithelial Cell Adhesion Molecule/metabolism , Receptor Protein-Tyrosine Kinases/metabolism , Gold/chemistry , Acrylic Resins/chemistry , Silver/chemistry , Surface Properties , Cell Line, Tumor , Aniline Compounds/chemistry , Particle Size , Cell Adhesion Molecules
14.
Biomacromolecules ; 25(5): 3141-3152, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38687279

ABSTRACT

Atherosclerosis (AS) is characterized by the accumulation of substantial low-density lipoprotein (LDL) and inflammatory response. Hemoperfusion is commonly employed for the selective removal of LDL from the body. However, conventional hemoperfusion merely focuses on LDL removal and does not address the symptom of plaque associated with AS. Based on the LDL binding properties of acrylated chondroitin sodium sulfate (CSA), acrylated beta-cyclodextrin (CD) and acrylic acid (AA), along with the anti-inflammatory property of rosiglitazone (R), the fabricated AA-CSA-CD-R microspheres could simultaneously release R and facilitate LDL removal for hemoperfusion. The AA and CSA offer electrostatic adsorption sites for LDL, while the CD provides hydrophobic adsorption sites for LDL and weak binding sites for R. According to the Sips model, the maximum static LDL adsorption capacity of AA-CSA-CD-R is determined to be 614.73 mg/g. In dynamic simulated perfusion experiments, AA-CSA-CD-R exhibits an initial cycle LDL adsorption capacity of 150.97 mg/g. The study suggests that the weakened inflammatory response favors plaque stabilization. The anti-inflammatory property of the microspheres is verified through an inflammation model, wherein the microsphere extracts are cocultured with mouse macrophages. Both qualitative analysis of iNOS\TNF-α and quantitative analysis of IL-6\TNF-α collectively demonstrate the remarkable anti-inflammatory effect of the microspheres. Therefore, the current study presents a novel blood purification treatment of eliminating pathogenic factors and introducing therapeutic factors to stabilize AS plaque.


Subject(s)
Acrylic Resins , Atherosclerosis , Chondroitin Sulfates , Lipoproteins, LDL , Rosiglitazone , Animals , Mice , Lipoproteins, LDL/chemistry , Lipoproteins, LDL/metabolism , Lipoproteins, LDL/isolation & purification , Chondroitin Sulfates/chemistry , Atherosclerosis/drug therapy , Atherosclerosis/metabolism , Acrylic Resins/chemistry , Rosiglitazone/pharmacology , Rosiglitazone/chemistry , Adsorption , RAW 264.7 Cells , Microspheres , Cyclodextrins/chemistry
15.
Lab Chip ; 24(9): 2440-2453, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38600866

ABSTRACT

Extensive research has demonstrated the potential of cell viscoelastic properties as intrinsic indicators of cell state, functionality, and disease. For this, several microfluidic techniques have been developed to measure cell viscoelasticity with high-throughput. However, current microchannel designs introduce complex stress distributions on cells, leading to inaccuracies in determining the stress-strain relationship and, consequently, the viscoelastic properties. Here, we introduce a novel approach using hyperbolic microchannels that enable precise measurements under a constant extensional stress and offer a straightforward stress-strain relationship, while operating at a measurement rate of up to 100 cells per second. We quantified the stresses acting in the channels using mechanical calibration particles made from polyacrylamide (PAAm) and found that the measurement buffer, a solution of methyl cellulose and phosphate buffered saline, shows strain-thickening following a power law up to 200 s-1. By measuring oil droplets with varying viscosities, we successfully detected changes in the relaxation times of the droplets and our approach could be used to get the interfacial tension and viscosity of liquid-liquid droplet systems from the same measurement. We further applied this methodology to PAAm microgel beads, demonstrating the accurate recovery of Young's moduli and the near-ideal elastic behavior of the beads. To explore the influence of altered cell viscoelasticity, we treated HL60 human leukemia cells with latrunculin B and nocodazole, resulting in clear changes in cell stiffness while relaxation times were only minimally affected. In conclusion, our approach offers a streamlined and time-efficient solution for assessing the viscoelastic properties of large cell populations and other microscale soft particles.


Subject(s)
Elasticity , Microfluidic Analytical Techniques , Viscosity , Humans , Microfluidic Analytical Techniques/instrumentation , Acrylic Resins/chemistry , Lab-On-A-Chip Devices , High-Throughput Screening Assays/instrumentation
16.
Anal Chem ; 96(18): 6906-6913, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38656893

ABSTRACT

Glycerol tributyrate as a low-density lipoprotein plays a crucial role in drug development and food safety. In this work, a novel high-stability fiber optic sensor for glyceryl tributyrate based on the poly(acrylic acid) (PAA) and chitosan (CS) composite hydrogel embedding method is first proposed. Compared with traditional functionalization, the lipase in a polymer network structure used in this article can not only avoid chemical reactions that cause damage to the enzyme structure but also avoid the instability of ionic bonds and physical adsorption. Therefore, the PAA/CS hydrogel method proposed in this article can effectively retain enzyme structure. First, the impact of different layers (one to five layers) of PAA/CS on pH sensing performance was explored, and it was determined that layers 1-3 could be used for subsequent sensing experiments. Within the linear detection range of 0.5-10 mM, the detection sensitivities of the one to three layers of the biosensor are divided into 0.65, 0.95, and 1.51 nm/mM, respectively, with the three layers having the best effect. When the number of coating layers is three, the detection limit of the sensor is 0.47 mM, meeting the millimole level detection standard for anticancer requirement. Furthermore, the stability and selectivity of the sensor (in the presence of hemoglobin, urea, cholesterol, acetylcholine, and glucose) were analyzed. The three-layer sensor is used for sample detection. At concentrations of 1-10 mM, the absolute value of the recovery percentage (%) is 82-99%, which can accurately detect samples. The sensor proposed in this paper has the advantages of low sample consumption, high sensitivity, simple structure, and label-free measurement. The enzyme-embedding method provides a new route for rapid and reliable glyceryl tributyrate detection, which has potential applications in food safety as well as the development of anticancer drugs.


Subject(s)
Acrylic Resins , Chitosan , Optical Fibers , Surface Plasmon Resonance , Acrylic Resins/chemistry , Chitosan/chemistry , Hydrogels/chemistry , Limit of Detection , Lipase/chemistry , Lipase/metabolism , Biosensing Techniques/methods
17.
Langmuir ; 40(19): 9926-9933, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38683632

ABSTRACT

Surface gel layers on commercially available contact lenses have been shown to reduce frictional shear stresses and mitigate damage during sliding contact with fragile epithelial cell layers in vitro. Spencer and co-workers recently demonstrated that surface gel layers could arise from oxygen-inhibited free-radical polymerization. In this study, polyacrylamide hydrogel shell probes (7.5 wt % acrylamide, 0.3 wt % N,N'-methylenebisacrylamide) were polymerized in three hemispherical molds listed in order of decreasing surface energy and increasing oxygen permeability: borosilicate glass, polyether ether ketone (PEEK), and polytetrafluoroethylene (PTFE). Hydrogel probes polymerized in PEEK and PTFE molds exhibited 100× lower elastic moduli at the surface (EPEEK* = 80 ± 31 and EPTFE* = 106 ± 26 Pa, respectively) than those polymerized in glass molds (Eglass* = 31,560 ± 1,570 Pa), in agreement with previous investigations by Spencer and co-workers. Biotribological experiments revealed that hydrogel probes with surface gel layers reduced frictional shear stresses against cells (τPEEK = 35 ± 15 and τPTFE = 22 ± 16 Pa) more than those without (τglass = 68 ± 15 Pa) and offered greater protection against cell damage when sliding against human telomerase-immortalized corneal epithelial (hTCEpi) cell monolayers. Our work demonstrates that the "mold effect" resulting in oxygen-inhibition polymerization creates hydrogels with surface gel layers that reduce shear stresses in sliding contact with cell monolayers, similar to the protection offered by gradient mucin gel networks across epithelial cell layers.


Subject(s)
Surface Properties , Humans , Hydrogels/chemistry , Polyethylene Glycols/chemistry , Polymers/chemistry , Acrylic Resins/chemistry
18.
Int J Mol Sci ; 25(7)2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38612578

ABSTRACT

Ultraviolet radiation (UVR) has various effects on human cells and tissues, which can lead to a variety of skin diseases and cause inconvenience to people's lives. Among them, solar dermatitis is one of the important risk factors for malignant melanoma, so prevention and treatment of solar dermatitis is very necessary. Additionally, liquiritin (LQ) has anti-inflammatory effects. In this study, we aimed to evaluate the anti-inflammatory and pro-wound healing effects of liquiritin carbomer gel cold paste (LQ-CG-CP) in vitro and in vivo. The results of MTT experiments showed no cytotoxicity of LQ at concentrations of 40 µg/mL and below and cell damage at UVB irradiation doses above 60 mJ/cm2. Moreover, LQ can promote cell migration. ELISA results also showed that LQ inhibited the elevation of the inflammatory factors tumor necrosis factor-α (TNF-α), interleukin-1ß (IL-1ß), and interleukin-6 (IL-6) after UVB irradiation. In the mouse model of solar dermatitis, 2% LQ-CG-CP showed the best therapeutic efficacy for wound healing and relief of itching compared to MEIBAO moist burn moisturizer (MEBO). What is more, the results of skin histopathological examination show that LQ-CG-CP promotes re-epithelialization, shrinks wounds, and promotes collagen production, thus promoting wound healing. Simultaneously, LQ-CG-CP reduced TNF-α, IL-1ß, and IL-6 expression. In addition, LQ-CG-CP was not observed to cause histopathological changes and blood biochemical abnormalities in mice. Overall, LQ-CG-CP has great potential for the treatment of solar dermatitis.


Subject(s)
Acrylic Resins , Dermatitis , Flavanones , Glucosides , Sunburn , Animals , Mice , Humans , Ultraviolet Rays , Interleukin-6 , Tumor Necrosis Factor-alpha , Wound Healing , Interleukin-1beta , Anti-Inflammatory Agents
19.
Pediatr Dent ; 46(2): 135-141, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38664912

ABSTRACT

Purpose: To compare surface roughness and bacterial colonization of Streptococcus mutans to 3D printed (3DP), milled (M), and conventional (CV) acrylic resin. Methods: Thirty-six discs (n equals 12 per group) were fabricated from 3DP, M, and CV materials. One surface of sample was polished (Po); the opposite surface was left unpolished (UPo). Surface roughness (µm) was assessed using a contact profilometer. The specimens were placed in S. mutans suspension and incubated at 37 degrees Celsius overnight. The attached colonies were separated using a sonicator, and the resulting solution was diluted to 10-3 to assess colony-forming units per milliliter (CFU/ml) after 48 hours. The colonies were categorized into a quantitative S. mutans (QS) index. Data were analyzed using one-way ANOVA, chi-squares, and multivariate analysis of variance analysis with the least significant difference (LSD) post-hoc test (P<0.05). Results: Roughness average (Ra) values of CV were higher than 3DP and M for UPo surfaces (P<0.001; 3DP=0.10; M=0.13; CV=0.26 µm, respectively). For Po and UPo surfaces, the CV harbored more S. mutans colonies than M and 3DP (P<0.001; 3DP=5.2x10 6 ; M=4.7x10 6 ; CV=1.49x10 7 CFU/ml, respectively). M group had the lowest range of QS scores, while CV had the highest range (P<0.001). Conclusions: Digitally manufactured material provides smoother surfaces than the conventional group, resulting in fewer Streptococcus mutans colonies. However, all the material groups must still be adequately polished to prevent the colonization of S. mutans, regardless of the manufacturing methods, as higher S. mutans counts were observed with an increase in surface roughness values.


Subject(s)
Acrylic Resins , Printing, Three-Dimensional , Streptococcus mutans , Surface Properties , Streptococcus mutans/growth & development , In Vitro Techniques , Dental Materials , Materials Testing , Humans , Colony Count, Microbial
20.
Dent Med Probl ; 61(2): 249-255, 2024.
Article in English | MEDLINE | ID: mdl-38652924

ABSTRACT

BACKGROUND: As polyether ether ketone (PEEK) is a relatively new material in dentistry, its bonding properties with regard to dental acrylic base materials are not fully known. To ensure the long-term success of removable dentures with a PEEK framework, the base materials must be well bonded to each other. OBJECTIVES: The study aimed to investigate the effects of different kinds of surface roughening treatment on PEEK and acrylic resin bonding. MATERIAL AND METHODS: Eighty PEEK specimens (N = 80) were randomly divided into 5 groups (n = 16 per group) and subjected to various surface roughening treatment (control, grinding, sandblasting, tribochemical silica coating (CoJet), and sulfuric acid etching). Heat-polymerized acrylic resin was applied to the treated surfaces of the PEEK specimens. The shear bond strength (SBS) test, environmental scanning electron microscopy (ESEM) analysis and three-dimensional (3D) surface topography analysis were performed. The statistical analysis of the data was conducted using the analysis of variance (ANOVA) and Tukey's multiple comparison test. RESULTS: The one-way ANOVA showed significant differences in the SBS values between the groups (p = 0.001). Sandblasting, tribochemical silica coating and sulfuric acid etching resulted in high SBS values (p = 0.001). The highest SBS values were observed in the sulfuric acid etching group (8.83 ±3.63 MPa), while the lowest SBS values were observed in the control group (3.33 ±2.50 MPa). CONCLUSIONS: The additional roughening treatment applied to the PEEK surface increases the bond strength with heat-polymerized acrylic resin.


Subject(s)
Acrylic Resins , Benzophenones , Dental Bonding , Ketones , Polyethylene Glycols , Polymers , Surface Properties , Pilot Projects , Ketones/chemistry , Polyethylene Glycols/chemistry , Acrylic Resins/chemistry , Microscopy, Electron, Scanning , Materials Testing , Humans , Shear Strength , Sulfuric Acids/chemistry , Dental Stress Analysis