Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 5.004
Filter
2.
Kyobu Geka ; 77(5): 357-360, 2024 May.
Article in Japanese | MEDLINE | ID: mdl-38720604

ABSTRACT

A 52-year-old woman with Marfan syndrome developed Stanford type B aortic dissection and was treated with thoracic endovascular aortic repair. However, 29 months later, she presented with retrograde Stanford type A aortic dissection. We successfully performed aortic arch replacement with the frozen elephant trunk technique and valve-sparing aortic root replacement. The advantages of the frozen elephant trunk technique are that the distal anastomosis can be created without stent-graft resection and the cardiac arrest time is shortened. Therefore, the frozen elephant trunk technique was considered valuable and safe in this potentially lethal situation.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Endovascular Procedures , Marfan Syndrome , Humans , Female , Marfan Syndrome/complications , Marfan Syndrome/surgery , Middle Aged , Aortic Dissection/surgery , Aortic Dissection/etiology , Aortic Dissection/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/etiology , Blood Vessel Prosthesis Implantation , Aorta, Thoracic/surgery , Aorta, Thoracic/diagnostic imaging , Endovascular Aneurysm Repair
3.
Catheter Cardiovasc Interv ; 103(6): 1074-1077, 2024 May.
Article in English | MEDLINE | ID: mdl-38577923

ABSTRACT

Transcatheter aortic valve implantation (TAVI) has traditionally been indicated for the treatment of aortic stenosis. However, in this case report, we describe a successful TAVI procedure in a 46-year-old male patient who had previously undergone David aortic valve-sparing aortic root replacement for type 1 aortic dissection. The patient presented with aortic valve insufficiency 4 years after the initial surgery and was subsequently treated with a 34 mm Medtronic CoreValve Evolut R prosthesis via TAVI. This case highlights the feasibility of TAVI as a viable treatment option for postoperative aortic valve insufficiency in patients with prior ascending aortic or aortic arch surgery.


Subject(s)
Aortic Dissection , Aortic Valve Insufficiency , Aortic Valve , Blood Vessel Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aortic Dissection/surgery , Aortic Dissection/diagnostic imaging , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/physiopathology , Middle Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Prosthesis Design , Blood Vessel Prosthesis , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm/surgery , Aortic Aneurysm/diagnostic imaging , Aortography
5.
Comput Biol Med ; 172: 108310, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38508054

ABSTRACT

Thoracic aortic aneurysm (TAA) is a local dilation of the thoracic aorta. Although universally used, aneurysm diameter alone is a poor predictor of major complications such as rupture. There is a need for better biomarkers for risk assessment that also reflect the aberrant flow patterns found in TAAs. Furthermore, hypertension is often present in TAA patients and may play a role in progression of aneurysm. The exact relation between TAAs and hypertension is poorly understood. This study aims to create a numerical model of hypertension in the aorta by using computational fluid dynamics. First, a normotensive state was simulated in which flow and resistance were kept unaltered. Second, a hypertensive state was modeled in which blood inflow was increased by 30%. Third, a hypertensive state was modeled in which the proximal and peripheral resistances and capacitance parameters from the three-element Windkessel boundary condition were adjusted to mimic an increase in resistance of the rest of the cardiovascular system. One patient with degenerative TAA and one healthy control were successfully simulated at hypertensive states and were extensively analyzed. Furthermore, three additional TAA patients and controls were simulated to validate our method. Hemodynamic variables such as wall shear stress, oscillatory shear index, endothelial cell activation potential (ECAP), vorticity and helicity were studied to gain more insight on the effects of hypertension on flow patterns in TAAs. By comparing a TAA patient and a control at normotensive state at peak-systole, helicity and vorticity were found to be lower in the TAA patient throughout the entire domain. No major changes in flow and flow derived quantities were observed for the TAA patient and control when resistance was increased. When flow rate was increased, regions with high ECAP values were found to reduce in TAA patients in the aneurysm region which could reduce the risk of thrombogenesis. Thus, it may be important to assess cardiac output in patients with TAA.


Subject(s)
Aneurysm, Ascending Aorta , Aortic Aneurysm, Thoracic , Hypertension , Humans , Hydrodynamics , Aortic Aneurysm, Thoracic/diagnostic imaging , Hemodynamics/physiology , Magnetic Resonance Spectroscopy
6.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38485695

ABSTRACT

Endovascular aortic arch repair (Ar-TEVAR) with single-branch, off-the-shelf Nexus aortic arch system has shown promising early and 3-year outcomes. There is lack of data regarding long-term results of this specific device, particularly regarding patency of supra-aortic bypasses and stability of the connection between the 2 modules. This case report describes 6-year clinical and imaging follow-up of a 74-year-old patient who underwent Ar-TEVAR with Nexus. Over 6 years, the patient experienced minor complications unrelated to the device. The patency of supra-aortic bypasses and integrity of the device's connection were confirmed. Computed tomography angiography constantly showed exclusion of the aneurysm and reduction of the aneurysmal sac. In conclusion, although extended research and broader data are needed, this case provides encouraging evidence of long-term results of Ar-TEVAR with Nexus.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Aged , Blood Vessel Prosthesis , Computed Tomography Angiography , Blood Vessel Prosthesis Implantation/methods , Stents , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Follow-Up Studies , Treatment Outcome , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Retrospective Studies
7.
Kyobu Geka ; 77(2): 101-105, 2024 Feb.
Article in Japanese | MEDLINE | ID: mdl-38459858

ABSTRACT

A 75-year-old woman was diagnosed with type B acute aortic dissection 14 years ago and 3-channeled aortic dissection 7 years ago. She received total arch replacement 6 years ago and descending aortic replacement with double barrel anastomosis technique for distal anastomosis 5 years ago. Computed tomography( CT) revealed giant thyroid tumor and thoracoabdominal aortic aneurysm( 58 mm in diameter). She suffered from back pain during her follow-up period. CT revealed ruptured thoracoabdominal aortic aneurysm. First, the false lumen of descending aorta was closed by thoracic endovascular aortic repair, and then thoracoabdominal aortic replacement was performed uneventfully.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Aneurysm, Thoracoabdominal , Aortic Dissection , Aortic Rupture , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Female , Aged , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Aorta/surgery , Aortic Rupture/diagnostic imaging , Aortic Rupture/surgery , Blood Vessel Prosthesis Implantation/methods , Anastomosis, Surgical , Treatment Outcome
8.
Kyobu Geka ; 77(2): 136-139, 2024 Feb.
Article in Japanese | MEDLINE | ID: mdl-38459863

ABSTRACT

A 67-year-old male was admitted to our hospital for sudden onset chest pain and hoarseness. He underwent 2-debranching thoracic endovascular aortic repair for a ruptured aortic arch aneurysm four years prior. However, computed tomography (CT) revealed an aneurysmal rerupture due to a typeⅠa endoleak. We performed partial arch replacement with uncovered stent removal under intermittent hypothermic circulatory arrest. We needed to be more careful than usual open heart surgery because a non-anatomical bypass procedure was performed. The surgery was successful without any major complications, and the patient was discharged on the 23th postoperative day. Reinterventions post-endovascular repair are sometimes difficult;thus, open surgery could be useful for arch replacement.


Subject(s)
Aneurysm, Aortic Arch , Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Male , Humans , Aged , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/surgery , Endovascular Aneurysm Repair , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/complications , Blood Vessel Prosthesis Implantation/adverse effects , Stents/adverse effects , Treatment Outcome , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Blood Vessel Prosthesis/adverse effects , Retrospective Studies
9.
Kyobu Geka ; 77(3): 163-168, 2024 Mar.
Article in Japanese | MEDLINE | ID: mdl-38465486

ABSTRACT

PURPOSE: We investigated the relationship between aortic remodeling and timing of thoracic endovascular aortic repair( TEVAR) in patients with uncomplicated Stanford type B aortic dissection. METHODS: 29 patients with sub-acute and early chronic uncomplicated Stanford type B aortic dissection underwent TEVAR between February 2019 and August 2022 in our hospital. We retrospectively compared aortic remodeling between 19 patients in the sub-acute( SA) group( 15-90 days from onset) and 10 patients in the early chronic( ECh) group( 91-365 days from onset) using the false luminal area reduction rate using computed tomography imagings. RESULTS: The false lumen area reduction rates at the level of the carina in the SA and ECh groups were 21.9±13.5% and 7.0±21.2% (p=0.04) around 3-8 days after TEVAR, 91.8±13.8% and 62.6±48.4 % (p=0.26) at 6 months, 96.6±7.2% and 68.7±42.5% (p=0.14) at 12 months, and 96.2±10.0% and 79.2±37.6% (p=0.62) at 18 months respectively. There were no significant differences between the two groups regarding any complication. CONCLUSION: Preemptive TEVAR for sub-acute and early chronic uncomplicated Stanford type B aortic dissection resulted in good remodeling and it may provide a good prognosis, especially in the subacute stage.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Endovascular Aneurysm Repair , Retrospective Studies , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Treatment Outcome , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Risk Factors
10.
J Vasc Surg ; 79(3): 457-468.e2, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38453660

ABSTRACT

BACKGROUND: Fenestrated and branched endovascular aortic repair (F/BEVAR) of thoracoabdominal aortic aneurysms (TAAAs) has shown high technical success and low early mortality rates. Aneurysm extent has been reported as a factor affecting outcomes. This study aimed to assess the early and midterm follow-up outcomes of patients managed by F/BEVAR for types I through III TAAAs. METHODS: A single-center retrospective analysis was conducted, including data from consecutive, elective and urgent (symptomatic and ruptured cases), patients treated for types I through III TAAAs, between October 1, 2011, and October 1, 2022, using F/BEVAR. Degenerative and postdissection TAAAs were included. Patients received prophylactic cerebrospinal fluid drainage (CSFD), except those under therapeutic anticoagulation, those who were hemodynamically unstable, or those with failed CSFD application. When an initial thoracic endovascular aortic repair was performed, as part of a staged procedure, no CSFD was used. Later stages and nonstaged procedures were performed under CSFD. Thirty-day mortality and major adverse events (MAEs) were analyzed. Kaplan-Meier estimates were used for follow-up outcomes. RESULTS: F/BEVAR for types I through III TAAAs was performed in 209 patients (56.9% males; mean age, 69.6 ± 3.2 years; mean aneurysm diameter, 65.2 ± 6.2 mm); 29.2% type I, 57.9% type II, and 12.9% type III. Urgent repair was performed in 26.7% of patients (56 cases; 23 ruptured and 33 symptomatic cases) and 153 were treated electively. Thirty-two patients (15.3%) were classified as American Society of Anesthesiologists (ASA) class IV. CSFD was used in 91% and staged thoracic endovascular aortic repair was performed in 51.2% of patients. Technical success was 93.8% (96.7% in elective vs 94.6% in urgent cases; P = .92). Thirty-day mortality was 11.0% (4.6% in elective vs 28.5% in urgent cases; P < .001) and MAEs were recorded in 17.2% of cases (7.8% in elective vs 42.8% in urgent cases; P < .001). Spinal cord ischemia rate was 20.5% (17.6% in elective vs 28.7% in urgent cases; P = .08), whereas 2.9% of patients presented paraplegia (1.3% in elective and 7.1% in urgent cases; P = .03). The mean follow-up was 16 ± 5 months. Survival was 75.0% (standard error, 4.0%) and freedom from reintervention was 73.3% (standard error, 4.4%) at 36 months. ASA IV and urgent repair were detected as independent factors related to early mortality and MAE, whereas ruptured aneurysm status was related to spinal cord ischemia evolution. CONCLUSIONS: Endovascular repair for types I through III TAAAs provides encouraging early outcomes in terms of mortality, MAE, and paraplegia, especially in an elective setting. Setting of repair and baseline ASA score should be taken into consideration during decision-making.


Subject(s)
Aortic Aneurysm, Abdominal , Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Spinal Cord Ischemia , Male , Humans , Aged , Female , Endovascular Aneurysm Repair , Blood Vessel Prosthesis , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Retrospective Studies , Risk Factors , Treatment Outcome , Endovascular Procedures/adverse effects , Spinal Cord Ischemia/etiology , Paraplegia/etiology
11.
BMJ Case Rep ; 17(3)2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38521516

ABSTRACT

A patient in his late 30s presented with issues of retrosternal chest pain and palpitations. He had sustained a splinter injury to the left hemithorax a year ago for which he had been managed with a tube thoracostomy. During subsequent evaluations, he was found to have atrial fibrillations and a CT angiography revealed an arch of the aorta pseudoaneurysm with a fistulous communication with the innominate vein, which being a rare condition has no established treatment protocols. Endovascular salvage of the condition required an aortic Ishimaru zone 2 deployment of the thoracic endovascular aortic repair stent graft to provide an adequate landing zone. The elective left subclavian artery revascularisation was obtained by a left carotid artery to left subclavian artery bypass. Post procedure there was complete exclusion of the pseudoaneurysm sac, and the fistulous aorto-venous communication inflow tract. The patient recuperated well and has returned to full active duties.


Subject(s)
Aneurysm, False , Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Thoracic Injuries , Humans , Male , Aneurysm, False/diagnostic imaging , Aneurysm, False/etiology , Aneurysm, False/surgery , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aorta, Thoracic/injuries , Aortic Aneurysm, Thoracic/complications , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Brachiocephalic Veins/diagnostic imaging , Brachiocephalic Veins/surgery , Prosthesis Design , Stents , Thoracic Injuries/surgery , Treatment Outcome , Adult
12.
Ann Vasc Surg ; 103: 99-108, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38395340

ABSTRACT

BACKGROUND: Takayasu Arteritis (TA) is an immune mediated arteritis causing inflammation of the aorta and its branches, which can result in aortic aneurysms. Our aim is to describe the outcome of surgical management in these patients who presented with Thoracoabdominal aortic aneurysm (TAAA). METHODS: Between 2003 and 2023, 40 TA patients with TAAA underwent operative repair. RESULTS: There were 24 females and 16 males, in the age group of 19-53 years, with hypertension in 20 patients. Raised Erythrocyte sedimentation Rate was present in 13 patients. According to Crawford classification, there were 2 patients with type I, 2 with type II, 17 with type III, 12 patients with type IV and 7 with type V aneurysm. Multiple steno-occlusive lesions of aortic branches were present in 21 patients, with majority affecting the renal artery. Femoral Artery Femoral Vein Partial cardiopulmonary bypass was used for types I, II, III and V. Separate bypass to visceral branches was done in eight patients, of whom five had multiple bypasses and three patients only had renal bypass. Twelve patients underwent reimplantation of branches, out of which nine had multiple vessel reimplantation. Four patients underwent staged repair of the aneurysm, which included visceral debranching in the first day, followed by repair of the aneurysm in the next day. In the immediate postoperative period, ten patients developed acute kidney injury and two required dialysis. Other morbidities included acute respiratory distress syndrome (ARDS), spinal cord dysfunction, bleeding, and wound complications. Three patients expired in the immediate postoperative period. Mean duration of intensive care unit stay was 4.1 days and hospital stay was 12.7 days. Comparison of disease activity with morbidity and mortality was statistically insignificant. Patients were on follow-up for a range of 6 months to 14 years and median follow-up of 25 months. Over this time period four patients expired and four developed anastomotic pseudoaneurysm requiring intervention. On comparing the disease activity at the time of surgery with the long-term arteritis related complications that required intervention, the P value was 0.653 and hence statistically not significant. The 10-year survival rate is 84.4%. CONCLUSIONS: Surgical repair has good and satisfactory outcome, with low early and late mortality rates. Progression of disease can occur at any stage of the disease, hence indicating the need for long term follow-up and frequent imaging.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Postoperative Complications , Takayasu Arteritis , Humans , Takayasu Arteritis/complications , Takayasu Arteritis/surgery , Takayasu Arteritis/diagnostic imaging , Female , Male , Retrospective Studies , Treatment Outcome , Adult , Middle Aged , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/mortality , Aortic Aneurysm, Thoracic/etiology , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Time Factors , Young Adult , Postoperative Complications/etiology , Risk Factors , Length of Stay , Computed Tomography Angiography , Cardiopulmonary Bypass , Aortic Aneurysm, Thoracoabdominal
13.
BMC Cardiovasc Disord ; 24(1): 124, 2024 Feb 26.
Article in English | MEDLINE | ID: mdl-38408908

ABSTRACT

BACKGROUND: This study aims to compare the clinical effects of two distinct surgical approaches, namely 3D printing-assisted extracorporeal pre-fenestration and Castor integrated branch stent techniques, in treating patients with Stanford type B aortic dissections (TBAD) characterized by inadequate proximal landing zones. METHODS: A retrospective analysis was conducted on 84 patients with type B aortic dissection (TBAD) who underwent thoracic endovascular aortic repair (TEVAR) with left subclavian artery (LSA) reconstruction at our center from January 2022 to July 2023. Based on the different surgical approaches, the patients were divided into two groups: the group assisted by 3D printing for extracorporeal pre-fenestration (n = 44) and the group using the castor integrated branch stent (n = 40). Clinical indicators: including general patient information, operative time, surgical success rate, intraoperative and postoperative complication rates, re-intervention rate, and mortality, as well as postoperative aortic remodeling, were compared between the two groups. The endpoint of this study is the post-TEVAR mortality rate in patients. RESULTS: The surgical success rate and device deployment success rate were 100% in both groups, with no statistically significant difference (P > 0.05). However, the group assisted by 3D printing for extracorporeal pre-fenestration had a significantly longer operative time (184.20 ± 54.857 min) compared to the group using the castor integrated branch stent (152.75 ± 33.068 min), with a statistically significant difference (t = 3.215, p = 0.002, P < 0.05). Moreover, the incidence of postoperative cerebral infarction and beak sign was significantly lower in the group assisted by 3D printing for extracorporeal pre-fenestration compared to the castor-integrated branch stent group, demonstrating statistical significance. There were no significant differences between the two groups in terms of other postoperative complication rates and aortic remodeling (P > 0.05). Notably, computed tomography angiography images revealed the expansion of the vascular true lumen and the reduction of the false lumen at three specified levels of the thoracic aorta. The follow-up duration did not show any statistically significant difference between the two groups (10.59 ± 4.52 vs. 9.08 ± 4.35 months, t = 1.561, p = 0.122 > 0.05). Throughout the follow-up period, neither group experienced new endoleaks, spinal cord injuries, nor limb ischemia. In the castor-integrated branch stent group, one patient developed a new distal dissection, prompting further follow-up. Additionally, there was one case of mortality due to COVID-19 in each group. There were no statistically significant differences between the two groups in terms of re-intervention rate and survival rate (P > 0.05). CONCLUSION: Both 3D printing-assisted extracorporeal pre-fenestration TEVAR and castor-integrated branch stent techniques demonstrate good safety and efficacy in treating Stanford type B aortic dissection with inadequate proximal anchoring. The 3D printing-assisted extracorporeal pre-fenestration TEVAR technique has a lower incidence of postoperative cerebral infarction and beak sign, while the castor-integrated branch stent technique has advantages in operative time.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Blood Vessel Prosthesis/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Retrospective Studies , Treatment Outcome , Endovascular Procedures/adverse effects , Time Factors , Stents/adverse effects , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Postoperative Complications/therapy , Aortography/methods , Cerebral Infarction/complications
14.
Ann Vasc Surg ; 101: 195-203, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38301850

ABSTRACT

BACKGROUND: The pathophysiology and behavior of acute type B intramural hematoma (TBIMH) is poorly understood. The purpose of this study is to characterize the pathophysiology, fate, and outcomes of TBIMH in the endovascular era. METHODS: A retrospective analysis of a US Aortic Database identified 70 patients with TBIMH from 2008 to 2022. Patients were divided into groups and analyzed based upon subsequent management: early thoracic endovascular aortic repair (TEVAR; Group 1) or hospital discharge on optimal medical therapy (OMT) (Group 2). RESULTS: Of 70 total patients, 43% (30/70) underwent TEVAR (Group 1) and 57% (40/70) were discharged on OMT (Group 2). There were no significant differences in age, demographics, or comorbidities between groups. Indications for TEVAR in Group 1 were as follows: 1) Penetrating atheroscletoic ulcer (PAU) or ulcer-like projection (n = 26); 2) Descending thoracic aortic aneurysm (n = 3); or 3) Progression to type B aortic dissection (TBAD) (n = 2). Operative mortality was zero. No patient suffered a stroke or spinal cord ischemia. During the follow-up period, 50% (20/40) of Group 2 patients required delayed surgical intervention, including TEVAR in 14 patients and open repair in 6 patients. Indications for surgical intervention were as follows: 1) Development of a PAU / ulcer-like projection (n = 13); 2) Progression to TBAD (n = 3), or 3) Concomitant aneurysmal disease (n = 4). Twenty patients did not require surgical intervention. Of the initial cohort, 71% of patients required surgery, 9% progressed to TBAD, and 19% had regression or stability of TBIMH with OMT alone. CONCLUSIONS: The most common etiology of TBIMH is an intimal defect. Progression to TBAD and intramural hematoma regression without an intimal defect occurs in a small percentage of patients. An aggressive strategy with endovascular therapy and close surveillance for TBIMH results in excellent short-term and long-term outcomes.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Retrospective Studies , Aorta, Thoracic/surgery , Ulcer/surgery , Treatment Outcome , Blood Vessel Prosthesis Implantation/adverse effects , Risk Factors , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/complications , Hematoma/diagnostic imaging , Hematoma/etiology , Hematoma/surgery
19.
Vasc Endovascular Surg ; 58(5): 505-511, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38258617

ABSTRACT

INTRODUCTION: We sought to examine midterm results and remodeling effect of false-lumen occlusion treatment using AFX VELA in case of chronic dissection repair. MATERIAL AND METHODS: From June 2019 to May 2022, we performed false lumen occlusion treatment using a modified Candy-Plug technique with AFX VELA on 8 chronic aortic dissection patients with a patent false lumen. We collected operative data, short-term clinical outcomes, mid-term clinical outcomes and imaging test results. We conducted follow-up examinations at postoperative, 6-month and 1-, 2- and 3-year intervals, including contrast-enhanced computed tomography to evaluate the diameter, false lumen thrombosis and any events. RESULTS: The average time from the symptom onset to the thoracic endovascular repair was 81.5 (35-155) months. The aorta showed aneurysmal dilation with an average maximum short-axis diameter of 58.9 (41-91) mm. Two cases needed emergency surgery due to rupture and impending rupture. There were no postoperative deaths. Complete thrombosis within the false lumen was achieved in 6 cases (75%), but 2 cases had incomplete thrombosis, requiring additional treatment. The mean maximum diameter showed a significant decrease at 6 months, 1 year and 2 years postoperatively compared to preoperative measurements (P < .05). CONCLUSION: We showed the results of false lumen occlusion treatment using the AFX VELA cuff. We observed favorable clinical outcomes and remodeling effects. While the long-term durability and efficacy of this technique in aortic remodeling will need to be monitored with further observation, the use of this cuff is considered a reliable approach to false lumen occlusion treatment.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endovascular Procedures , Humans , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Aortic Dissection/physiopathology , Male , Middle Aged , Treatment Outcome , Chronic Disease , Aged , Female , Time Factors , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/adverse effects , Retrospective Studies , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/physiopathology , Prosthesis Design , Stents , Vascular Remodeling
SELECTION OF CITATIONS
SEARCH DETAIL
...