Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 3.490
Filter
1.
Ann Card Anaesth ; 27(1): 51-52, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38722121

ABSTRACT

ABSTRACT: The quadricuspid aortic valve is a rare congenital anomaly, usually associated with aortic regurgitation requiring surgical intervention. It may be associated with other congenital anomalies such as coronary anomalies, patent ductus arteriosus, ventricular septal defect, pulmonary stenosis, and subaortic stenosis. The diagnosis is generally established by either transthoracic or transesophageal echocardiography. Herein, we report a case of a 52-year-old woman who was diagnosed to have quadricuspid aortic valve by intraoperative transesophageal echocardiography.


Subject(s)
Aortic Valve , Echocardiography, Transesophageal , Humans , Female , Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Middle Aged , Echocardiography, Transesophageal/methods , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery
2.
Ann Card Anaesth ; 27(1): 53-57, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38722122

ABSTRACT

ABSTRACT: Aortic valve (AV) repair is the desired surgical treatment option for young patients with aortic regurgitation (AR). It is considered as a class I indication for the surgical treatment of severeAR. The success of an AV repair depends on the detailed intraoperative transesophageal echocardiographic (TEE) examination which should fulfil the information required by the surgeon. The objective of this echo round is to describe the role of intraoperative TEE in systematic evaluation of the AV, before and after repair.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve , Echocardiography, Transesophageal , Monitoring, Intraoperative , Humans , Echocardiography, Transesophageal/methods , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Child , Monitoring, Intraoperative/methods
3.
Surg Innov ; 31(3): 256-262, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38565982

ABSTRACT

OBJECTIVE: In this case report, the auxiliary role of deep learning and 3-dimensional printing technology in the perioperative period was discussed to guide transcatheter aortic valve replacement and coronary stent implantation simultaneously. CASE PRESENTATION: A 68-year-old man had shortness of breath and chest tightness, accompanied by paroxysmal nocturnal dyspnea, 2 weeks before presenting at our hospital. Echocardiography results obtained in the outpatient department showed severe aortic stenosis combined with regurgitation and pleural effusion. The patient was first treated with closed thoracic drainage. After 800 mL of pleural effusion was collected, the patient's symptoms were relieved and he was admitted to the hospital. Preoperative transthoracic echocardiography showed severe bicuspid aortic valve stenosis combined with calcification and aortic regurgitation (mean pressure gradient, 42 mmHg). Preoperative computed tomography results showed a type I bicuspid aortic valve with severe eccentric calcification. The leaflet could be seen from the left coronary artery plane, which indicated an extremely high possibility of coronary obstruction. After preoperative imaging assessment, deep learning and 3-dimensional printing technology were used for evaluation and simulation. Guided transcatheter aortic valve replacement and a coronary stent implant were completed successfully. Postoperative digital subtraction angiography showed that the bioprosthesis and the chimney coronary stent were in ideal positions. Transesophageal echocardiography showed normal morphology without paravalvular regurgitation. CONCLUSION: The perioperative guidance of deep learning and 3-dimensional printing are of great help for surgical strategy formulation in patients with severe bicuspid aortic valve stenosis with calcification and high-risk coronary obstruction.


Subject(s)
Aortic Valve Stenosis , Deep Learning , Printing, Three-Dimensional , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Male , Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Stents , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/abnormalities , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging
4.
Catheter Cardiovasc Interv ; 103(6): 1074-1077, 2024 May.
Article in English | MEDLINE | ID: mdl-38577923

ABSTRACT

Transcatheter aortic valve implantation (TAVI) has traditionally been indicated for the treatment of aortic stenosis. However, in this case report, we describe a successful TAVI procedure in a 46-year-old male patient who had previously undergone David aortic valve-sparing aortic root replacement for type 1 aortic dissection. The patient presented with aortic valve insufficiency 4 years after the initial surgery and was subsequently treated with a 34 mm Medtronic CoreValve Evolut R prosthesis via TAVI. This case highlights the feasibility of TAVI as a viable treatment option for postoperative aortic valve insufficiency in patients with prior ascending aortic or aortic arch surgery.


Subject(s)
Aortic Dissection , Aortic Valve Insufficiency , Aortic Valve , Blood Vessel Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aortic Dissection/surgery , Aortic Dissection/diagnostic imaging , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/physiopathology , Middle Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Prosthesis Design , Blood Vessel Prosthesis , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm/surgery , Aortic Aneurysm/diagnostic imaging , Aortography
5.
Catheter Cardiovasc Interv ; 103(6): 1015-1022, 2024 May.
Article in English | MEDLINE | ID: mdl-38577931

ABSTRACT

BACKGROUND: Previous studies have documented a high rate of implantation success with the ACURATE neo2 valve, as well as a reduction in paravalvular leak (PVL) compared to its predecessor, the ACURATE neo. However, there are no studies that have reviewed and compared the long-term clinical and hemodynamic outcomes of these patients. AIMS: This study aimed to evaluate the results of the ACURATE neo transcatheter aortic valve in a real-world context, and to compare the results of the outcomes of both generations of this device (ACURATE neo and ACURATE neo2), with a specific focus on procedural success, safety, and long-term effectiveness. METHODS: A prospective study including all consecutive patients treated with the ACURATE neo device in seven hospitals was conducted (Clinical Trials Identification Number: NCT03846557). The primary endpoint consisted of a composite of adverse events, including mortality, aortic insufficiency, and other procedural complications. As the second-generation device (ACURATE neo2) replaced the ACURATE neo during the study period, hemodynamic and clinical results before admission, at 30 days, and at 1 year of follow-up were compared between the two generations. RESULTS: A total of 296 patients underwent transcatheter aortic valve implantation with the ACURATE device, with 178 patients receiving the ACURATE neo and 118 patients receiving the ACURATE neo2. In the overall population, the absence of device success occurred in 14.5%. The primary reason for the absence of device success was the presence of para-valvular regurgitation ≥ 2. There were no instances of coronary occlusions, valve embolization, annulus rupture, or procedural deaths. ACURATE neo2 was associated with a significantly higher device success rate (91.7% vs. 82%, p = 0.04), primarily due to a significantly lower rate of para-valvular regurgitation, which remained significant at 1 year. CONCLUSION: The use of ACURATE neo and neo2 transcatheter aortic valves is associated with satisfactory clinical results and an extremely low rate of complications. The ACURATE neo2 enables a significantly higher device success rate, primarily attributed to a significant reduction in the rate of PVL.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Hemodynamics , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Postoperative Complications , Prospective Studies , Recovery of Function , Risk Factors , Spain , Time Factors , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
6.
Echocardiography ; 41(4): e15817, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38648213

ABSTRACT

BACKGROUND: Quadricuspid aortic valve (QAV) is a rare congenital disease. The clinical characteristics of this disease remain unclear except for those in relatively young patients reported from tertiary referral hospitals. The aim of this study was to determine the clinical features of QAV in a regional population. METHODS AND RESULTS: We retrospectively investigated 25 340 consecutive patients over middle age (median age, 73 (IQR 65-80) years; range, 45-102 years) who underwent transthoracic echocardiography (TTE) at our institute during the period from April 2008 to December 2023. Eight (0.032%) of the patients (median age, 65 years; range, 47-91 years) were diagnosed with QAV. Six patients suffered from aortic regurgitation (AR), and one patient had mild aortic stenosis at the time of QAV diagnosis. Two patients who had severe AR at referral underwent aortic valve surgery. The severity of AR in the other patients was moderate or less. During a median follow-up period of 27 months (range, 1-171 months), none of the patients other than above two patients had cardiac events. One patient died from a non-cardiac cause at 94 years of age. CONCLUSIONS: Patients diagnosed with QAV after middle age, who do not exhibit severe valve insufficiency at the time of diagnosis, may not experience worse clinical outcomes. However, further research is required for a better understanding of the long-term outcomes.


Subject(s)
Aortic Valve , Echocardiography , Humans , Female , Male , Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aged , Retrospective Studies , Middle Aged , Aged, 80 and over , Echocardiography/methods , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Heart Defects, Congenital/diagnostic imaging , Follow-Up Studies
7.
J Am Heart Assoc ; 13(9): e032532, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38686861

ABSTRACT

BACKGROUND: This study was performed to determine cusp causes of aortic regurgitation in patients with tricuspid aortic valves without significant aortic dilatation and define cusp pathologies amenable to surgical repair (aortic valve repair [AVr]) versus aortic valve replacement. METHODS AND RESULTS: We retrospectively reviewed surgical reports of consecutive adults with tricuspid aortic valves undergoing surgery for clinically significant aortic regurgitation within a prospective registry from January 2005 to September 2019. Valvular mechanisms were determined by systematic in vivo intraoperative quantification methods. Of 516 patients, 287 (56%) underwent repair (AVr; mean±SD age, 59.9±12.4 years; 81% men) and 229 (44%) underwent replacement (aortic valve replacement; mean±SD age, 62.8±13.8 years [P=0.01 compared to AVr]; 67% men). A single valvular mechanism was present in 454 patients (88%), with cusp prolapse (46%), retraction (24%), and perforation (18%) being the most common. Prolapse involved the right cusp in 86% of cases and was more frequent in men (P<0.001). Two-dimensional transesophageal echocardiography accuracy for predicting mechanisms was 73% to 82% for the right cusp, 55% to 61% for the noncoronary cusp, and 0% for the left-coronary cusp. Cusp prolapse, younger age, and larger patient size were associated with successful AVr (all P<0.03), whereas retraction, perforation, older age, and concomitant mitral repair were associated with aortic valve replacement (all P<0.03). CONCLUSIONS: Right cusp prolapse is the most frequent single valvular mechanism in patients with tricuspid aortic valve aortic regurgitation, followed by cusp retraction and perforation. The accuracy of 2-dimensional transesophageal echocardiography is limited for left and noncoronary cusp mechanistic assessment. Prolapse is associated with successful AVr, whereas retraction and perforation are associated with aortic valve replacement. With systematic intraoperative quantification methods and current surgical techniques, more than half of tricuspid aortic valve aortic regurgitation cases may be successfully repaired.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve , Echocardiography, Transesophageal , Heart Valve Prosthesis Implantation , Humans , Male , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Middle Aged , Female , Retrospective Studies , Heart Valve Prosthesis Implantation/adverse effects , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aged , Tricuspid Valve/surgery , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/physiopathology , Treatment Outcome , Registries , Cardiac Valve Annuloplasty/methods
8.
BMC Cardiovasc Disord ; 24(1): 163, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38504187

ABSTRACT

BACKGROUND: Aortic valve reconstruction using glutaraldehyde-treated autologous pericardium, also called Ozaki procedure, is a surgical procedure for patients with aortic valve disease. Gratifying results have been reported in adult patients, however, limited published data is available in paediatric population. This study looked at clinical characteristics and early outcomes of children who underwent Ozaki procedure at our Institute. METHODS: This was a retrospective descriptive study conducted on children who underwent aortic valve reconstruction at Jakaya Kikwete Cardiac Institute (JKCI) from January 2019 through December 2022. Medical records of these children were reviewed to extract data on demographics, clinical characteristics, redo surgical interventions and survival. RESULTS: A total of 10 children underwent Ozaki procedure during the study period. Eight children had severe aortic regurgitation while 2 had severe aortic stenosis preoperatively. All children had either none or trivial aortic regurgitation immediately after surgery. None of them had redone operations throughout the follow-up period. There was no in-hospital mortality, however, one child died one-year after surgery. The mean follow-up period was 1.6 years with the longest follow-up time of 4 years. CONCLUSION: Ozaki procedure showed encouraging early results among children with aortic valve disease who underwent surgical repair by this technique. Future studies with larger sample sizes and longer follow up periods to evaluate long-term results in this population are recommended.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Adult , Child , Humans , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/surgery , Retrospective Studies , Tanzania , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Pericardium/transplantation , Treatment Outcome
11.
Kyobu Geka ; 77(3): 206-209, 2024 Mar.
Article in Japanese | MEDLINE | ID: mdl-38465492

ABSTRACT

We report a case of bioprosthetic valve dysfunction and acute aortic valve regurgitation. The case was a 75-year-old female who had sudden onset chest pain. ST-segment depression in several leads on electrocardiogram( ECG) suggested acute coronary syndrome. Coronary angiography showed no significant stenosis in coronary arteries. Transesophageal echocardiography revealed severe aortic regurgitation, suggesting that angina was caused by myocardial ischemia associated with acute aortic regurgitation. She was diagnosed as having bioprosthetic valve dysfunction, and underwent redo aortic valve replacement. One leaflet of the bioprosthetic valve was torn along the stent post and caused bioprosthetic valve dysfunction. Failed bioprosthetic valve was removed and replaced by a mechanical valve.


Subject(s)
Aortic Valve Insufficiency , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Female , Humans , Aged , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Thorax , Heart Valve Prosthesis/adverse effects , Chest Pain/etiology , Bioprosthesis/adverse effects , Heart Valve Prosthesis Implantation/adverse effects
13.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38544298

ABSTRACT

Pure aortic regurgitation and dilation of aortic annulus are the most significant risk factors for the failure of pulmonary autograft after the Ross procedure. Aortic annuloplasty has a positive effect on the durability of the autograft. Previously, we described a technique for external annuloplasty with dedicated CORONEO ring. In the present manuscript, we suggest the sizing of annuloplasty based on the diameter of pulmonary autograft annulus.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Pulmonary Valve , Humans , Autografts , Transplantation, Autologous/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/etiology , Aortic Valve Stenosis/surgery , Reoperation/adverse effects , Pulmonary Valve/transplantation , Treatment Outcome , Follow-Up Studies
14.
J Cardiovasc Surg (Torino) ; 65(1): 69-75, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38300164

ABSTRACT

BACKGROUND: Type A aortic dissection (TAAD) surgical management is still under debate. The purpose of this study was to demonstrate the feasibility and safety of the aortic valve-sparing root reconstruction (AVSR) procedure in 92 consecutive patients operated for TAAD, even when preoperative condition was severe (malperfusion, shock or both). METHODS: Our hospital database was reviewed to identify all patients who underwent an AVSR procedure for TAAD over 14 years. From May 2000 to June 2014, 92 consecutive patients were studied regarding to their preoperative condition. RESULTS: Age (61±13 years) and logistic Euroscore (23.4±15.3%) as well as cross-clamping (113±39 min), cardiopulmonary bypass (142±49 min) and circulatory arrest (22±13 min) times were collected. Hospital mortality was 16.3%. Mean follow-up was complete for a mean period of 27.6 months. One patient had early reoperation for aortic insufficiency. Actuarial survival at 1 year was 82.5%. The analysis of each group showed comparable mortality and morbidity in between patients. CONCLUSIONS: Based upon our experience in the management of TAAD, a reimplantation procedure could be performed regardless preoperative malperfusion or shock, with an acceptable postoperative over mortality or morbidity. A word of caution should be brought to patients over 70 years old.


Subject(s)
Aortic Aneurysm , Aortic Dissection , Aortic Valve Insufficiency , Azides , Deoxyglucose/analogs & derivatives , Humans , Middle Aged , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/surgery , Treatment Outcome , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/surgery , Reoperation , Replantation/adverse effects , Contraindications , Retrospective Studies
15.
BMJ Case Rep ; 17(2)2024 Feb 23.
Article in English | MEDLINE | ID: mdl-38395470

ABSTRACT

The Trifecta tissue valve (Abbott, Illinois, USA) is an externally mounted bovine pericardial aortic valve (AV) prosthesis with adequate haemodynamic performance and better early results than another option. However, concerns have been raised about its durability. Recently, reports have emerged about an increased incidence of early structural valve failure after Trifecta implantation, where leaflet tear(s) with dehiscence along the stent post was the primary mode of early failure. In this article, we present the case of a patient in her 70s, 7 years after AV replacement with a Trifecta valve, who developed progressive dyspnoea. Physical examination revealed signs of chronic severe aortic regurgitation (AR). The initial transthoracic echocardiogram showed severe transvalvular AR, but the aetiology could not be determined. Cardiac computed tomography (CT) revealed a flail non-coronary cusp of the Trifecta bioprosthetic valve without vegetation. After discussion, we concluded that our patient was suitable for valve-in-valve transcatheter aortic valve replacement (ViV TAVR).


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Female , Humans , Animals , Cattle , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Prosthesis Failure , Bioprosthesis/adverse effects , Prosthesis Design , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/methods , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery
16.
J Am Heart Assoc ; 13(4): e033289, 2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38362873

ABSTRACT

BACKGROUND: The management of mixed aortic valve disease (MAVD), defined as the concomitant presence of aortic stenosis (AS) and aortic regurgitation, remains a clinical challenging. The present study assessed the impact of transcatheter aortic valve replacement (TAVR) on cardiac geometry and prognosis in patients with MAVD. METHODS AND RESULTS: A retrospective multicenter TAVR registry was conducted, including patients who underwent TAVR for severe symptomatic AS between January 2015 and March 2019. Patients were subdivided into 2 groups according to concomitant presence of moderate or more severe aortic regurgitation as the MAVD group, and with mild or less severe aortic regurgitation as the isolated AS group. The primary outcome was a composite of cardiovascular death and rehospitalization due to cardiovascular causes. A total of 1742 patients (isolated AS, 1522 patients; MAVD, 220 patients) were included (84.0±5.2 years). Although MAVD exhibited significantly larger left ventricular volumes and higher left ventricular mass index at the TAVR procedure than isolated AS (respectively, P<0.001), MAVD showed a greater improvement of left ventricular volumes and left ventricular mass index after TAVR (respectively, P≤0.001). During a median follow-up of 747 days, 301 patients achieved the primary event. The prognosis post-TAVR was comparable between the 2 groups (log-rank P=0.65). Even after adjustment using propensity score matching to reduce the potential bias between the 2 groups, similar results were obtained for the entire cohort. CONCLUSIONS: Despite more advanced cardiac remodeling in MAVD at the time of TAVR compared with isolated AS, a greater improvement of cardiac reverse remodeling was found in MAVD, and the prognosis following TAVR was comparable between the 2 groups.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/etiology , Treatment Outcome , Risk Factors , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Prognosis , Retrospective Studies , Severity of Illness Index , Ventricular Function, Left
20.
J Cardiovasc Comput Tomogr ; 18(2): 179-186, 2024.
Article in English | MEDLINE | ID: mdl-38262851

ABSTRACT

BACKGROUND: Quadricuspid aortic valve (QAV) is a rare congenital heart disease with a limited body of literature. This retrospective cohort study investigates QAV morphology, function, and clinical outcomes. METHODS: Echocardiography was used to assess valvular function. Morphological characteristics such as phenotypes, raphe, regurgitant orifice area (ROA), and aortic dilation (diameter >40 â€‹mm) were assessed by cardiac CT. Patients were followed up for the combined event of all-cause death and aortic valve replacement (AVR). RESULTS: Ninety QAV patients (screened from 322385 CT scans) were included (mean age 55.2 â€‹± â€‹13.6 years, 61.1 â€‹% male). Isolated significant aortic regurgitation (AR) was present in 75.6 â€‹% of patients. The cohort was dominated by type I (four equal leaflets, 37.8 â€‹%) and type II (3 larger and 1 smaller leaflets, 42.2 â€‹%) QAV. Fused raphe was present in 26.7 â€‹% of patients. ROACT was correlated with AR severity and aortic dilation (41.1 â€‹%, n â€‹= â€‹37). Among patients without AVR at baseline (n â€‹= â€‹60), one died and 17 underwent AVR during a median follow-up of 35.0 months (IQR:17.3-62.8). ROACT was associated with an increasing risk of combined event (as a categorical variable with a cut-off of 21.4 â€‹mm2, HR â€‹= â€‹4.25, 95%CI 1.49-12.17, p â€‹= â€‹0.007; as a continuous variable (per mm2 increment), HR â€‹= â€‹1.04, 95%CI 1.01-1.07, p â€‹= â€‹0.003). Additionally, ROACT had incremental prognostic value when added to the AR severity model (area under the receiver-operating characteristic curve increased from 86.8 to 88.4, p â€‹= â€‹0.004). CONCLUSION: QAV is characterized by variable anatomy, progressive AR, concomitant cusp fusion and aortic enlargement. ROACT may be a potential ancillary prognostic marker in patients with QAV.


Subject(s)
Aortic Diseases , Aortic Valve Insufficiency , Quadricuspid Aortic Valve , Humans , Male , Adult , Middle Aged , Aged , Female , Retrospective Studies , Predictive Value of Tests , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/abnormalities , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Hemodynamics
SELECTION OF CITATIONS
SEARCH DETAIL
...