Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
J Chromatogr A ; 1636: 461766, 2021 Jan 11.
Article in English | MEDLINE | ID: mdl-33316562

ABSTRACT

To evaluate the endocannabinoid system in an animal model of Parkinson's disease, in-tube solid-phase microextraction (in-tube SPME) was directly coupled to a tandem mass spectrometry (MS/MS) system for determination of the endocannabinoids anandamide (AEA) and 2-arachidonoylglycerol (2-AG) in rat brain samples. In-tube SPME-which consisted of a microtube of restricted access material (RAM) with a hydrophilic diol external surface and a hydrophobic octyl inner surface-efficiently excluded (up to 95%) macromolecules from the biological samples and selectively pre-concentrated the analytes. In-tube SPME parameters, such as sample volume, mobile phases, flow rate, and pre-concentration time, were evaluated to improve the extraction efficiency and throughput performance. The selectivity of the in-tube SPME and MS/MS (MRM mode) techniques allowed them to be directly coupled online, which dismissed the need for the chromatographic separation step. The in-tube SPME-MS/MS method was validated and shown to be linear from 6.0 to 30.0 ng mL-1 for AEA and from 10.0 to 100.0 ng mL-1 for 2-AG; the intra- and inter-assay accuracy and precision were lower than 15%. Parallelism between the calibration curves constructed in the matrix and aqueous solution confirmed that there was no matrix effect. The method allowed endogenous concentrations of AEA and 2-AG to be determined in rat brain striatum from unilaterally 6-hydroxydopamine-lesioned animals. The concentrations of these endocannabinoids in striatum ipsilateral and contralateral to the lesion differed significantly (p<0.001).


Subject(s)
Arachidonic Acids/analysis , Brain/metabolism , Endocannabinoids/analysis , Glycerides/analysis , Polyunsaturated Alkamides/analysis , Tandem Mass Spectrometry/methods , Animals , Arachidonic Acids/isolation & purification , Arachidonic Acids/standards , Brain/drug effects , Calibration , Chromatography, High Pressure Liquid , Endocannabinoids/isolation & purification , Endocannabinoids/standards , Glycerides/isolation & purification , Glycerides/standards , Hydrophobic and Hydrophilic Interactions , Male , Oxidopamine/pharmacology , Polyunsaturated Alkamides/isolation & purification , Polyunsaturated Alkamides/standards , Rats , Rats, Wistar , Solid Phase Microextraction , Tandem Mass Spectrometry/standards
2.
Bioanalysis ; 4(19): 2343-56, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23088461

ABSTRACT

BACKGROUND: Quantitation of biomarkers by LC-MS/MS is complicated by the presence of endogenous analytes. This challenge is most commonly overcome by calibration using an authentic standard spiked into a surrogate matrix devoid of the target analyte. A second approach involves use of a stable-isotope-labeled standard as a surrogate analyte to allow calibration in the actual biological matrix. For both methods, parallelism between calibration standards and the target analyte in biological matrix must be demonstrated in order to ensure accurate quantitation. RESULTS: In this communication, the surrogate matrix and surrogate analyte approaches are compared for the analysis of five amino acids in human plasma: alanine, valine, methionine, leucine and isoleucine. In addition, methodology based on standard addition is introduced, which enables a robust examination of parallelism in both surrogate analyte and surrogate matrix methods prior to formal validation. Results from additional assays are presented to introduce the standard-addition methodology and to highlight the strengths and weaknesses of each approach. CONCLUSION: For the analysis of amino acids in human plasma, comparable precision and accuracy were obtained by the surrogate matrix and surrogate analyte methods. Both assays were well within tolerances prescribed by regulatory guidance for validation of xenobiotic assays. When stable-isotope-labeled standards are readily available, the surrogate analyte approach allows for facile method development. By comparison, the surrogate matrix method requires greater up-front method development; however, this deficit is offset by the long-term advantage of simplified sample analysis.


Subject(s)
Amino Acids/blood , Chromatography, Liquid , Tandem Mass Spectrometry , Amino Acids/standards , Arachidonic Acids/blood , Arachidonic Acids/standards , Biomarkers/analysis , Chromatography, Liquid/standards , Endocannabinoids/blood , Endocannabinoids/standards , Glycerides/blood , Glycerides/standards , Humans , Isotope Labeling , Methylhistidines/blood , Polyunsaturated Alkamides/blood , Polyunsaturated Alkamides/standards , Reference Standards , Tandem Mass Spectrometry/standards
3.
Clin Chem Lab Med ; 44(4): 488-91, 2006.
Article in English | MEDLINE | ID: mdl-16599845

ABSTRACT

BACKGROUND: Endogenous ligands of cannabinoid receptors (endocannabinoids), in particular anandamide (arachidonylethanolamide), have been recognized as being of crucial importance in a variety of physiological functions. Plasma concentrations of anandamide have been measured in a number of investigations; however, discrepant data on "normal" anandamide plasma concentrations were reported. Since this might be caused by pre-analytical variables, we investigated the impact of different sample handling conditions on measured plasma anandamide concentrations. METHODS: Blood samples were taken from healthy volunteers in EDTA- or heparin-containing tubes; whole blood samples were kept at +4 degrees C, room temperature, or 37 degrees C, respectively, for up to 120 min before obtaining plasma by centrifugation. Plasma anandamide concentrations were measured by an isotope-dilution liquid chromatography tandem mass spectrometry (LC-MS/MS) method. RESULTS: A marked time- and temperature-dependent increase in plasma anandamide concentrations ex vivo was observed in both EDTA- and heparin-containing tubes. Mean anandamide concentrations approximately doubled when EDTA samples were kept at 4 degrees C for 60 min before centrifugation [immediately centrifuged, 1.3 microg/L (SD 0.3 microg/L); 2.8 microg/L (SD 0.5 microg/L) after storage for 60 min; n=12). After storage of heparinized whole-blood samples for 120 min at 37 degrees C, a mean plasma anandamide concentration of 11.9 microg/L (SD 1.8 microg/L) was found. In cell-free plasma, no increase in anandamide concentrations was found. CONCLUSION: Anandamide is released from blood cells ex vivo at a very high rate; therefore, strictly standardized pre-analytical protocols have to be applied for plasma anandamide determination.


Subject(s)
Arachidonic Acids/blood , Blood Specimen Collection/standards , Arachidonic Acids/metabolism , Arachidonic Acids/standards , Blood Cells/metabolism , Blood Preservation/methods , Blood Specimen Collection/methods , Chromatography, High Pressure Liquid , Chromatography, Liquid , Endocannabinoids , Humans , Polyunsaturated Alkamides , Temperature , Time Factors
4.
Anal Biochem ; 295(2): 262-6, 2001 Aug 15.
Article in English | MEDLINE | ID: mdl-11488631

ABSTRACT

5-Oxo-6,8,11,14-eicosatetraenoic acid (5-oxo-ETE), a metabolite of arachidonic acid formed by the 5-lipoxygenase pathway, is a potent eosinophil chemoattractant that may be an important mediator in asthma. To further investigate the physiological and pathological roles of 5-oxo-ETE we have developed a mass spectrometric assay employing a tetradeuterated analog (5-oxo-[11,12,14,15-(2)H]ETE) as an internal standard. Collision-induced dissociation of the quasimolecular anion of 5-oxo-[11,12,14,15-(2)H]ETE (m/z 321) resulted in the formation of a major ion at m/z 207 that retained all four deuterium atoms. Measurement of the ratio of ions at m/z 203 (endogenous 5-oxo-ETE) and m/z 207 permitted quantitation of this compound by liquid chromatography-mass spectrometry-mass spectrometry using multiple reaction monitoring. The resulting assay was highly sensitive (< or =20 pg/sample) and selective, enabling detection of the amount of 5-oxo-ETE produced by as few as 10,000 neutrophils. This assay should permit measurement of 5-oxo-ETE in biological fluids, enabling evaluation of its role in asthma and other inflammatory diseases.


Subject(s)
Arachidonic Acids/analysis , Mass Spectrometry/methods , Arachidonic Acids/standards , Body Fluids/chemistry , Chromatography, High Pressure Liquid , Chromatography, Liquid , Deuterium , Humans , Reference Standards
SELECTION OF CITATIONS
SEARCH DETAIL