Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 894
Filter
1.
Korean J Radiol ; 25(5): 449-458, 2024 May.
Article in English | MEDLINE | ID: mdl-38685735

ABSTRACT

Selective fascicular involvement of the median nerve trunk above the elbow leading to anterior interosseous nerve (AIN) syndrome is a rare form of peripheral neuropathy. This condition has recently garnered increased attention within the medical community owing to advancements in imaging techniques and a growing number of reported cases. In this article, we explore the topographical anatomy of the median nerve trunk and the clinical features associated with AIN palsy. Our focus extends to unique manifestations captured through MRI and ultrasonography (US) studies, highlighting noteworthy findings, such as nerve fascicle swelling, incomplete constrictions, hourglass-like constrictions, and torsions, particularly in the posterior/posteromedial region of the median nerve. Surgical observations have further enhanced the understanding of this complex neuropathic condition. High-resolution MRI not only reveals denervation changes in the AIN and median nerve territories but also illuminates these alterations without the presence of compressing structures. The pivotal roles of high-resolution MRI and US in diagnosing this condition and guiding the formulation of an optimal treatment strategy are emphasized.


Subject(s)
Magnetic Resonance Imaging , Median Nerve , Ultrasonography , Humans , Magnetic Resonance Imaging/methods , Median Nerve/diagnostic imaging , Ultrasonography/methods , Arm/innervation , Arm/diagnostic imaging , Median Neuropathy/diagnostic imaging , Syndrome
2.
J Orthop Surg Res ; 19(1): 193, 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38504340

ABSTRACT

BACKGROUND: The importance of several scapulothoracic muscles, including trapezius and serratus anterior, in maintaining physiological scapula kinematics has been highlighted in the past. However, the relationship between the scapula and the latissimus dorsi muscle remains unclear. Our clinical surgical observation is that the latissimus dorsi does not directly attach but rather runs superficial to the inferior angle of the scapula. Based on this observation, we hypothesise that the latissimus dorsi creates a dynamic track on which the scapula glides under the muscle belly during elevation of the arm, creating the latissimus-scapula overlap (LSO). METHODS: All consecutive patients who had a whole-body computed tomography scan (CT) in case of polytrauma evaluation between 2018 and 2021, with complete depiction of the scapula and latissimus dorsi muscle, were analysed. 150 shoulders in 90 patients with arms up were matched according to their age (within five years), gender, and affected side with 150 shoulders in 88 patients with arms down. Patients with pathologies of the upper extremities or thorax that potentially could alter LSO measurements were excluded. LSO was calculated as a ratio of the measured area of the latissimus dorsi projection on the scapula and the total scapula area. RESULTS: The mean age of the 178 patients (48 females; 13 males) was 60 years. The arms-up group showed a significantly higher LSO than the arms-down group (19.9 ± 6.3% vs. 2.7 ± 2.2%; p < 0.0001). In the arms-up group, approximately one fifth of the scapula was overlapped inferiorly by the muscle belly of the latissimus dorsi, contrary to the almost non-existing LSO in the arms-down group. CONCLUSION: With arms up, humans show a significantly higher LSO in comparison to arms down indicating that the latissimus dorsi indeed creates a dynamic track on which the scapula is forced to travel during abduction of the arm. This finding of increased LSO during the elevation of the arm warrants further consideration of the role of the latissimus dorsi in scapula kinematics and potentially scapular dyskinesis. LEVEL OF EVIDENCE: Level two diagnostic study.


Subject(s)
Congenital Abnormalities , Scapula/abnormalities , Shoulder Joint/abnormalities , Superficial Back Muscles , Male , Female , Humans , Child, Preschool , Superficial Back Muscles/diagnostic imaging , Arm/diagnostic imaging , Scapula/surgery , Shoulder
3.
Radiography (Lond) ; 30(2): 681-687, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38364708

ABSTRACT

INTRODUCTION: This retrospective cohort study examined the effects of the crossed raised arm (CRA) position in contrast-enhanced computed tomography (CECT) on contrast medium influx and image quality relative to the conventional position. METHODS: Contrast medium influx into the collateral veins on CECT images was evaluated in 92 participants. The CT values of the pulmonary artery, descending aorta, and spleen were obtained in both positions and compared. Anatomical changes in the diameters and area of the subclavian vein and costoclavicular distance were also analyzed. RESULTS: Contras 27 and 6 patients in the conventional and CRA positions, respectively. The influx risk ratio in the CRA position versus that in the conventional position was 0.22 (95% confidence interval, 0.10-0.51). Elevations in the median CT value of the pulmonary artery, descending aorta, and spleen in the CRA position were 7.0% (p < .001), 7.4% (p < .001), and 9.8% (p < .001), respectively. Enlargements in the major and minor diameters of the subclavian vein, subclavian vein area, and costoclavicular distance in the CRA position versus those in the conventional position were 19.3% (p < .001), 28.1% (p < .001), 53.6%, and 30.0% (p < .001), respectively. CONCLUSION: The CRA position effectively prevented contrast medium influx into the collateral veins due to SVS and increased CT values in the target organs in CECT. The diameters and area of the subclavian vein and costoclavicular distance were enlarged at the thoracic outlet, which improved the flow of the contrast medium into the targeted organs. IMPLICATIONS FOR PRACTICE: The CRA position can contribute to obtaining better CECT images during common clinical assessments at no additional cost.


Subject(s)
Arm , Tomography, X-Ray Computed , Humans , Arm/diagnostic imaging , Retrospective Studies , Tomography, X-Ray Computed/methods , Contrast Media , Abdomen
4.
Radiography (Lond) ; 30(1): 416-421, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38181465

ABSTRACT

INTRODUCTION: This study aimed to investigate and compare the effective dose (ED) delivered by computed tomography (CT) in whole-body positron emission tomography/CT (WB-PET/CT) scans between patients positioned with their arms-raised and those with their arms-lowered during the scan on a large population. METHODS: The retrospective study involved 785 oncology patients who underwent WB-PET/CT scans with 18F-FDG between January and June 2019. Exclusion criteria were applied, resulting in a final analysis of data from 732 adult patients. All of the patients were measured height and weight, and the ED from CT in WB-PET/CT was estimated using the dose length product value and a conversion factor. Statistical analyses were conducted to explore relationships between factors and the ED. Linear regression analysis was performed to investigate connections between weight and ED, and height and ED. Multiple linear regression was used to predict ED based on sex, weight, and arm position. RESULTS: The arm-lowered group had a higher ED than the arm-raised group, and the median dose was 1.1 times higher in the arm-lowered group. The difference in ED between the two groups was found to be greater with higher body weight. Arm-position (ß = 0.460), sex (ß = -0.190), and weight (ß = 0.057) were significant predictors of ED. CONCLUSION: This study demonstrated that arm position, sex, and weight were significant factors influencing the ED from CT scans in WB-PET/CT. IMPLICATIONS FOR PRACTICE: The research underscores the importance of considering these factors when evaluating radiation exposure in clinical practice, particularly for patients undergoing WB-CT imaging. These findings contribute to a better understanding of the radiation dosimetry associated with different patient positions during WB-PET/CT scans.


Subject(s)
Fluorodeoxyglucose F18 , Positron Emission Tomography Computed Tomography , Adult , Humans , Arm/diagnostic imaging , Positron Emission Tomography Computed Tomography/methods , Positron-Emission Tomography , Radiopharmaceuticals , Retrospective Studies , Tomography, X-Ray Computed , Male , Female
5.
Article in English | MEDLINE | ID: mdl-38083105

ABSTRACT

The creation of unique control methods for a hand prosthesis is still a problem that has to be addressed. The best choice of a human-machine interface (HMI) that should be used to enable natural control is still a challenge. Surface electromyography (sEMG), the most popular option, has a variety of difficult-to-fix issues (electrode displacement, sweat, fatigue). The ultrasound imaging-based methodology offers a means of recognising complex muscle activity and configuration with a greater SNR and less hardware requirements as compared to sEMG. In this study, a prototype system for high frame rate ultrasound imaging for prosthetic arm control is proposed. Using the proposed framework, a virtual robotic hand simulation is developed that can mimic a human hand as illustrated in the link: https://youtu.be/LBcwQ0xzQK0. The proposed classification model simulating four hand gestures has a classification accuracy of more than 90%.Clinical relevance-The proposed system enables an ultrasound imaging based human machine interface that can be a research and development platform for novel control strategies of a hand prosthesis.


Subject(s)
Artificial Limbs , Robotics , Humans , Arm/diagnostic imaging , Electromyography/methods , Upper Extremity
6.
J Clin Ultrasound ; 51(9): 1512-1521, 2023.
Article in English | MEDLINE | ID: mdl-37787651

ABSTRACT

PURPOSE: Studies examining mortality in palliative care units are limited. We aimed to investigate the mortality and associated factors including ultrasonographic muscle parameters in hospitalized palliative patients with a subgroup analysis of older patients. METHODS: A prospective-observational study. We recorded the demographics, number of diseases, diagnoses, and the Charlson comorbidity index (CCI), palliative performance scale (PPS), and nutritional risk screening-2002 (NRS-2002) scores. We noted the nutritional parameters and mortality. We measured the subcutaneous fat thickness (SFT), muscle thickness (MT), and cross-sectional area (CSA) of the rectus femoris and biceps brachii using ultrasonography. RESULTS: We enrolled 100 patients (mean age: 73.2 ± 16.4 years, 53%: female). One-month mortality was 42%. The non-survivors had significantly higher malignancy, increased CCI and NRS-2002 scores, lower required energy intake, calorie sufficiency rate, and biceps brachii SFT, MT, and CSA than the survivors. The independent mortality predictors were malignancy and biceps brachii CSA while the PPS score and malignancy were significantly associated with mortality in the older subgroup. CONCLUSION: The malignancy and biceps brachii CSA might have prognostic value in predicting mortality in palliative patients. This was the first study investigating the mortality-associated factors including ultrasonographic muscle measurements of both the lower and upper limbs in a palliative care center.


Subject(s)
Muscle, Skeletal , Neoplasms , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Prospective Studies , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/physiology , Arm/diagnostic imaging , Ultrasonography , Neoplasms/diagnostic imaging
7.
Ultrasound Med Biol ; 49(1): 398-409, 2023 01.
Article in English | MEDLINE | ID: mdl-36266142

ABSTRACT

Shear wave elastography is an emerging diagnostic tool used to assess for changes in the stiffness of muscle. Each region of the muscle may have a different stiffness; therefore, the anatomical region should be carefully selected. Machine vendors each have unique methods for calculating the returned stiffness values and, consequently, a high level of agreement in measurement between machines (quantified using the intraclass correlation coefficient [ICC] and Bland-Altman analysis) will allow research findings to be translated to the clinic. This study assessed three locations within the biceps muscle (50% and 75% of the distance between the acromioclavicular joint and antecubital fossa, and superior to distal myotendinous junction [MTJ]) of 32 healthy volunteers with two different machines, the Canon Aplio i600 and SuperSonic Imagine Aixplorer (SSI), to compare the reported shear wave velocities and the variability by coefficient of variation (CV) and ICC. There was no difference in the CV between machines, but a significant difference in the CV at muscle regions, with the 75% location having a 40.2% reduction in CV. The 75% location had the highest ICC values with good posterior mean ICCs of 0.84 on the Canon and 0.83 on the SSI. The 50% and MTJ locations had poor ICC values. The 75% location provided the lowest CV and highest ICC and should be used for future stiffness assessments.


Subject(s)
Elasticity Imaging Techniques , Humans , Elasticity Imaging Techniques/methods , Ultrasonography/methods , Arm/diagnostic imaging , Muscle, Skeletal/diagnostic imaging , Elbow , Reproducibility of Results
8.
Radiologia (Engl Ed) ; 64(6): 525-532, 2022.
Article in English | MEDLINE | ID: mdl-36402538

ABSTRACT

INTRODUCTION AND OBJECTIVES: Obtaining CCTA images with optimal injection location such as the arm or leg is important to avoid the artifacts caused by the CM. This study compares the computed tomography (CT) numbers and visualization scores of the three-dimensional (3D) images of the lumens of the blood vessels in the arm or leg during cardiac computed tomography angiography (CCTA) in neonatal and infant patients. PATIENTS OR MATERIALS AND METHODS: Between January 2017 and January 2020, 253 consecutive patients were considered for inclusion. We used the estimated propensity scores as a function of the demographic data, including age, body weight, and injection location (right or left side) in the arm (n = 58) and leg (n = 58) of neonatal and infant patients. We compared the mean CT numbers of the pulmonary artery, ascending aorta, and left superior vena cava; contrast-noise ratios (CNR); and visualization scores between the arm and leg as the injection locations. RESULTS: The mean CT numbers during CCTA for the arm and leg were 479.4 and 461.3 HU in the ascending aorta, 464.2 and 448.1 HU in the pulmonary artery, and 232.8 and 220.1 HU in the left superior vena cava, respectively. The mean image noise (SD) and CNR values, respectively, were 38.9 HU and 12.1 for the arm as the injection location and 39.1 HU and 12.3 for the leg as the injection location. The median visualization scores of volume rendering of the 3D images were 3.0 and 3.0 for the arm and leg injection sites, respectively. There were no significant differences in the mean CT numbers of the ascending aorta, pulmonary artery, and left superior vena cava; SD value; CNR; and visualization scores between the arm and leg injection locations. CONCLUSIONS: The CT numbers of the lumen of the blood vessel and visualization scores of the 3D images of the arm and leg injection locations are equal during CCTA in neonatal and infant patients with congenital heart disease.


Subject(s)
Contrast Media , Vena Cava, Superior , Humans , Infant , Infant, Newborn , Arm/diagnostic imaging , Leg , Tomography, X-Ray Computed/methods
9.
NMR Biomed ; 35(7): e4696, 2022 07.
Article in English | MEDLINE | ID: mdl-35052014

ABSTRACT

Quantitative magnetic resonance imaging (qMRI) is frequently used to map the disease state and disease progression in the lower extremity muscles of patients with spinal muscular atrophy (SMA). This is in stark contrast to the almost complete lack of data on the upper extremity muscles, which are essential for carrying out daily activities. The aim of this study was therefore to assess the disease state in the upper arm muscles of patients with SMA in comparison with healthy controls by quantitative assessment of fat fraction, diffusion indices, and water T2 relaxation times, and to relate these measures to muscle force. We evaluated 13 patients with SMA and 15 healthy controls with a 3-T MRI protocol consisting of DIXON, diffusion tensor imaging, and T2 sequences. qMRI measures were compared between groups and related to muscle force measured with quantitative myometry. Fat fraction was significantly increased in all upper arm muscles of the patients with SMA compared with healthy controls and correlated negatively with muscle force. Additionally, fat fraction was heterogeneously distributed within the triceps brachii (TB) and brachialis muscle, but not in the biceps brachii muscle. Diffusion indices and water T2 relaxation times were similar between patients with SMA and healthy controls, but we did find a slightly reduced mean diffusivity (MD), λ1, and λ3 in the TB of patients with SMA. Furthermore, MD was positively correlated with muscle force in the TB of patients with SMA. The variation in fat fraction further substantiates the selective vulnerability of muscles. The reduced diffusion tensor imaging indices, along with the positive correlation of MD with muscle force, point to myofiber atrophy. Our results show the feasibility of qMRI to map the disease state in the upper arm muscles of patients with SMA. Longitudinal data in a larger cohort are needed to further explore qMRI to map disease progression and to capture the possible effects of therapeutic interventions.


Subject(s)
Arm , Muscular Atrophy, Spinal , Arm/diagnostic imaging , Diffusion Tensor Imaging/methods , Disease Progression , Humans , Magnetic Resonance Imaging/methods , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/pathology , Muscular Atrophy, Spinal/diagnostic imaging , Upper Extremity/diagnostic imaging , Water
10.
Comput Math Methods Med ; 2022: 6470576, 2022.
Article in English | MEDLINE | ID: mdl-35096133

ABSTRACT

This study was to explore the application value for central venous stenosis and occlusion in hemodialysis patients under the CT angiography based on intelligent segmentation algorithm, so that patients can survive better. Spiral CT was used to examine upper limb swelling in 62 uremic hemodialysis patients at a speed of 3.8 mL/s. Nonionic iodine contrast agent was injected around the contralateral limb. The total dosage of 90-102 mL, it was scanned by intelligent trigger technology. The trigger scanning threshold was set. The monitoring point was located in the superior vena cava. CT with convolutional neural network intelligent segmentation algorithm was used to process image data. Finally, the quality of life and related biochemical levels of patients before and after hemodialysis were detected. Under the CT angiography of intelligent segmentation algorithm, 77 stenoses were found in 62 uremic patients, including 48 stenoses of the brachial vein and 17 stenoses of the superior vena cava. The correlation coefficient between CT angiography and digital subtraction angiography (DSA) imaging results of intelligent segmentation algorithm was 0.411. Segmentation effect of the algorithm in this study: automatic segmentation accuracy was greater than 79%. After hemodialysis treatment, the scores of physical fitness, pain, social function, and energy status of patients were significantly increased compared with those before treatment, and the levels of albumin, serum phosphorus, and parathyroid hormone were significantly decreased (P < 0.05). In summary, CT angiography with intelligent segmentation algorithm can obtain clear, intuitive, and complete vascular walking images, and better display subclavian vein, brachiocephalic vein, and superior vena cava. It can provide more valuable support for surgical intervention and has certain application value for better survival of hemodialysis patients.


Subject(s)
Algorithms , Computed Tomography Angiography/methods , Renal Dialysis , Adult , Aged , Angiography, Digital Subtraction/methods , Angiography, Digital Subtraction/statistics & numerical data , Arm/diagnostic imaging , Computational Biology , Computed Tomography Angiography/statistics & numerical data , Edema/diagnostic imaging , Female , Humans , Imaging, Three-Dimensional/methods , Imaging, Three-Dimensional/statistics & numerical data , Male , Middle Aged , Multidetector Computed Tomography/methods , Multidetector Computed Tomography/statistics & numerical data , Neural Networks, Computer , Renal Dialysis/adverse effects , Upper Extremity Deep Vein Thrombosis/diagnostic imaging , Upper Extremity Deep Vein Thrombosis/etiology , Uremia/diagnostic imaging , Uremia/therapy , Vascular Access Devices/adverse effects , Vena Cava, Superior/diagnostic imaging , Young Adult
11.
J Neurol ; 269(5): 2619-2626, 2022 May.
Article in English | MEDLINE | ID: mdl-34676447

ABSTRACT

BACKGROUND: Flail arm syndrome is a restricted phenotype of motor neuron disease that is characterized by progressive, predominantly proximal weakness and atrophy of the upper limbs. OBJECTIVE: The study was designed to investigate specific white matter alterations in diffusion tensor imaging (DTI) data from flail arm syndrome patients using a hypothesis-guided tract-of-interest-based approach to identify in vivo microstructural changes according to a neuropathologically defined amyotrophic lateral sclerosis (ALS)-related pathology of the cortico-efferent tracts. METHODS: DTI-based white matter mapping was performed both by an unbiased voxel-wise statistical comparison and by a hypothesis-guided tract-wise analysis of fractional anisotropy (FA) maps according to the neuropathological ALS-propagation pattern for 43 flail arm syndrome patients vs 43 'classical' ALS patients vs 40 matched controls. RESULTS: The analysis of white matter integrity demonstrated regional FA reductions for the flail arm syndrome group predominantly along the CST. In the tract-specific analysis according to the proposed sequential cerebral pathology pattern of ALS, the flail arm syndrome patients showed significant alterations of the specific tract systems that were identical to 'classical' ALS if compared to controls. CONCLUSIONS: The DTI study including the tract-of-interest-based analysis showed a microstructural involvement pattern in the brains of flail arm syndrome patients, supporting the hypothesis that flail arm syndrome is a phenotypical variant of ALS.


Subject(s)
Amyotrophic Lateral Sclerosis , Vascular Diseases , Amyotrophic Lateral Sclerosis/complications , Amyotrophic Lateral Sclerosis/diagnostic imaging , Amyotrophic Lateral Sclerosis/pathology , Anisotropy , Arm/diagnostic imaging , Arm/pathology , Brain Mapping , Diffusion Tensor Imaging/methods , Disease Progression , Humans , Image Processing, Computer-Assisted/methods , Pyramidal Tracts
12.
J Ultrasound Med ; 41(2): 355-364, 2022 Feb.
Article in English | MEDLINE | ID: mdl-33830545

ABSTRACT

OBJECTIVES: Semiautomatic fractional limb volume (FLV) models have recently produced promising results for fetal birth weight (BW) estimation. We tested those models in a more unselected population hypothesizing that the FLV models would improve accuracy and precision of fetal BW estimation compared to the Hadlock model. METHODS: We compared the performance of different BW prediction models: Hadlock (biparietal diameter [BPD], abdominal circumference (AC), femur diaphysis length) and modified Lee thigh volume (TVol) and arm volume (AVol) (BPD, AC, automated fractional TVol, and AVol). Accuracy (systematic errors, mean percent differences) and precision (random errors, ± 1 SD of percent differences) were calculated. RESULTS: A total of 75 fetuses were included for final analysis. The Hadlock model showed the most consistent results with accurate BW estimation not significantly different from zero (-0.37 ± 8.53%). The modified fractional thigh and arm volume models were less accurate but trended toward more precise results (-2.63 ± 7.69% and -3.85 ± 7.47%, respectively). In addition, the modified TVol model showed the trend to predict more BWs within ±10% of the actual BW compared to the Hadlock model (81.3 versus 74.67%, ns). CONCLUSIONS: Based on our results, fetal weight estimation using the modified semiautomatic FLV models generates less accurate results in third-trimester fetuses compared to the Hadlock model. Those models recently published might improve the results of BW prediction by showing a higher precision than conventional models, especially in small and large fetuses. Further studies are needed to investigate the clinical usefulness of the new models.


Subject(s)
Fetal Weight , Ultrasonography, Prenatal , Arm/diagnostic imaging , Birth Weight , Female , Gestational Age , Humans , Pregnancy , Prospective Studies
13.
Lymphat Res Biol ; 20(1): 39-47, 2022 02.
Article in English | MEDLINE | ID: mdl-33761290

ABSTRACT

Background: Lymphedema (LE) is a significant clinical problem for breast cancer survivors. While the water displacement test and circumferential assessment using a tape measure (TM) are common methods to assess differences in arm volumes, faster and more reliable methods are needed. Study purposes, in breast cancer survivors (n = 294), were to compare the average total arm volumes and interlimb volume ratios for women with and without a history of LE, using a TM and three-dimensional (3D), whole-body surface scanner (3D scan); compare the level of agreement between arm volumes and interlimb volume ratios obtained using the two devices; and evaluate the percent agreement between the two measures in classifying cases of LE using three accepted thresholds. Methods and Results: Measurements were done using a spring-loaded TM and Fit3D ProScanner. Paired t-tests and Bland-Altman analyses were used to achieve the study aims. For circumference and volume comparisons, compared with the 3D scan, values obtained using the TM were consistently smaller. In terms of level of agreement, the Bland-Altman analyses demonstrated large biases and wide limits of agreement for the calculated arm volumes and volume ratios. In terms of the classification of caseness, using the 200-mL interlimb volume difference criterion resulted in 81.6% overall agreement; using the >10% volume difference between the affected and unaffected arms resulted in 78.5% overall agreement; and using the volume ratio ≥1.04 criterion resulted in 62.5% overall agreement. For all three accepted threshold criteria, the percentage of cases was significantly different between the TM and 3D scan techniques. Conclusions: The 3D technology evaluated in this study has the potential to be used for self-initiated surveillance for LE. With improvements in landmark identification and software modifications, it is possible that accurate and reliable total arm volumes can be calculated and used for early detection.


Subject(s)
Breast Cancer Lymphedema , Breast Neoplasms , Cancer Survivors , Lymphedema , Arm/diagnostic imaging , Breast Cancer Lymphedema/diagnostic imaging , Breast Cancer Lymphedema/etiology , Breast Neoplasms/complications , Breast Neoplasms/diagnostic imaging , Female , Humans , Lymphedema/diagnostic imaging , Lymphedema/etiology
14.
Dermatol Online J ; 27(8)2021 Aug 15.
Article in English | MEDLINE | ID: mdl-34755959

ABSTRACT

Eosinophilic fasciitis (EF) and generalized morphea (GM) are rare and difficult-to-treat sclerosing skin diseases which may occur in association with hematologic disorders. We present a 66-year-old man with EF and associated Waldenström macroglobulinemia who received combination therapy with rituximab (375mg/m2 every other week, gradually extended to every eight weeks), prednisolone (1.25-30mg/d), and methotrexate (7.5-15mg/w). Three months after rituximab initiation, his skin condition improved steadily accompanied by a significant improvement in joint mobility with only mild and transitory flares (observation period: 59 months under treatment with rituximab). To date, there are five case reports on rituximab treatment of EF/GM with an association to hypergammaglobulinemia in three of those cases. Therapy effected significant improvement in four patients. Our case adds to the hitherto limited evidence that rituximab may be a promising therapeutic strategy for EF/GM in association with hypergammaglobulinemia.


Subject(s)
Eosinophilia/drug therapy , Fasciitis/drug therapy , Immunologic Factors/therapeutic use , Rituximab/therapeutic use , Waldenstrom Macroglobulinemia/complications , Aged , Arm/diagnostic imaging , Drug Therapy, Combination , Eosinophilia/complications , Eosinophilia/diagnostic imaging , Eosinophilia/pathology , Fasciitis/complications , Fasciitis/diagnostic imaging , Fasciitis/pathology , Glucocorticoids/therapeutic use , Humans , Male , Methotrexate/therapeutic use , Prednisolone/therapeutic use
16.
Parkinsonism Relat Disord ; 91: 96-101, 2021 10.
Article in English | MEDLINE | ID: mdl-34547655

ABSTRACT

BACKGROUND: The supplementary motor area (SMA) is implicated in stereotypic multi-limb movements such as walking with arm swing. Gait difficulties in Parkinson's Disease (PD) include reduced arm swing, which is associated with reduced SMA activity. OBJECTIVE: To test whether enhanced arm swing improves Parkinsonian gait and explore the role of the SMA in such an improvement. METHODS: Cortical activity and gait characteristics were assessed by ambulant EEG, accelerometers and video recordings in 27 PD patients with self-reported gait difficulties and 35 healthy participants when walking normally. Within these two groups, 19 PD patients additionally walked with enhanced arm swing and 30 healthy participants walked without arm swing. Power changes across the EEG frequency spectrum were assessed by Event Related Spectral Perturbation analysis of recordings from Fz over the putative SMA and gait analysis was performed. RESULTS: Baseline PD gait, characterized by reduced arm swing among other features, exhibited reduced within-step Event Related Desynchronization (ERD)/Synchronization (ERS) alternation (Fz; 20-50Hz), accompanied by a reduced step length and walking speed. All became similar to normal gait when patients walked with enhanced arm swing. When healthy controls walked without arm swing, their alternating ERD-ERS pattern decreased, mimicking baseline PD gait. CONCLUSION: Enhanced arm swing may serve as a driving force to overcome impaired gait control in PD patients by restoring reduced ERD-ERS alternation over the putative SMA. Accompanied by increased step length and walking speed, this provides a neural underpinning of arm swing as an effective rehabilitation concept for improving Parkinsonian gait.


Subject(s)
Electroencephalography , Gait Disorders, Neurologic/physiopathology , Gait , Parkinson Disease/physiopathology , Accelerometry , Aged , Arm/diagnostic imaging , Arm/physiopathology , Case-Control Studies , Female , Gait Analysis , Gait Disorders, Neurologic/diagnostic imaging , Gait Disorders, Neurologic/etiology , Humans , Male , Motor Cortex/physiopathology , Parkinson Disease/complications , Parkinson Disease/diagnostic imaging , Video Recording , Walking , Walking Speed
17.
Nutrients ; 13(7)2021 Jul 09.
Article in English | MEDLINE | ID: mdl-34371860

ABSTRACT

Identification of low muscle mass becomes increasingly relevant due to its prognostic value in cancer patients. In clinical practice, mid-upper arm muscle circumference (MAMC) and bioelectrical impedance analysis (BIA) are often used to assess muscle mass. For muscle-mass assessment, computed tomography (CT) is considered as reference standard. We investigated concordance between CT, BIA, and MAMC, diagnostic accuracy of MAMC, and BIA to detect low muscle mass and their relation with the clinical outcome malnutrition provided with the Patient-Generated Subjective Global Assessment Short Form (PG-SGA SF). This cross-sectional study included adult patients with advanced esophageal and gastrointestinal cancer. BIA, MAMC, and PG-SGA-SF were performed. Routine CT-scans were used to quantify psoas muscle index (PMI) and skeletal muscle area. Good concordance was found between CTPMI and both BIAFFMI (fat free mass index) (ICC 0.73), and BIAASMI (appendicular skeletal muscle index) (ICC 0.69) but not with MAMC (ICC 0.37). BIAFFMI (94%), BIAASMI (86%), and MAMC (86%) showed high specificity but low sensitivity. PG-SGA-SF modestly correlated with all muscle-mass measures (ranging from -0.17 to -0.43). Of all patients with low muscle mass, 62% were also classified with a PG-SGA-SF score of ≥4 points. Although CT remains the first choice, since both BIA and MAMC are easy to perform by dieticians, they have the potential to be used to detect low muscle mass in clinical practice.


Subject(s)
Anthropometry/methods , Electric Impedance , Muscle, Skeletal/physiopathology , Nutrition Assessment , Sarcopenia/diagnosis , Aged , Arm/diagnostic imaging , Arm/physiopathology , Body Mass Index , Cross-Sectional Studies , Esophageal Neoplasms/complications , Esophageal Neoplasms/physiopathology , Female , Gastrointestinal Neoplasms/complications , Gastrointestinal Neoplasms/physiopathology , Humans , Male , Malnutrition/complications , Malnutrition/physiopathology , Middle Aged , Muscle, Skeletal/diagnostic imaging , Nutritional Status , Prospective Studies , Reproducibility of Results , Sarcopenia/etiology , Sensitivity and Specificity , Tomography, X-Ray Computed
18.
J Drugs Dermatol ; 20(7): 755-759, 2021 Jul 01.
Article in English | MEDLINE | ID: mdl-34232003

ABSTRACT

OBJECTIVE: The HIFEM procedure demonstrates positive outcomes on abdomen and buttock. This multi-center study aims to investigate its effect on adipose tissue and muscle mass located in upper arms and calves. MATERIALS AND METHODS: Twenty subjects (45.10±15.19 years, 24.44±3.22 kg/m2) who underwent a HIFEM procedure (4 sessions; 20 minutes per muscle group) on arms and calves were evaluated. Overall, 7 patients were treated over biceps and triceps, 4 patients over calves, and 9 patients underwent treatment of both upper arms and calves. The changes in adipose and muscle tissue of musculus biceps brachii, triceps brachii, and gastrocnemius were evaluated by using ultrasound. The results from a 1-month, 3-month, and 6-month follow-up were compared to the baseline. Digital photographs, weight measurements, satisfaction, and comfort questionnaires were assessed at baseline and follow-ups. RESULTS: Ultrasound images revealed a significant (P<0.05) increase in the muscle mass of all studied muscles, with the most noticeable improvement in biceps brachii (+16.13% at 3 months). The fat deposits over arms and calves showed significant improvement (P<0.05), reaching -15.12% at 3 months. The results peaked at 3 months and were sustained up to 6 months with a slight but insignificant decline. Aesthetic enhancement of treated areas was documented while patients were highly satisfied. CONCLUSIONS: The achieved outcomes showed that the HIFEM procedure is effective for muscle toning and fat reduction in arms and calves. The results suggest that the use of the HIFEM procedure is not limited only to abdominal and buttock shaping but is also effective for toning of arms and calves. J Drugs Dermatol. 2021;20(7):755-759. doi:10.36849/JDD.5878.


Subject(s)
Electromagnetic Fields , Magnetic Field Therapy , Animals , Arm/diagnostic imaging , Cattle , Humans , Lifting , Ultrasonography
19.
Medicine (Baltimore) ; 100(25): e26314, 2021 Jun 25.
Article in English | MEDLINE | ID: mdl-34160395

ABSTRACT

RATIONALE: Nasal-type, extranodal natural killer (NK)/T-cell lymphoma is a rare lymphoma. The tumor usually shows ulcerative and necrotic lesions in the nasal cavities and sinuses. Tissue involvement outside the nasal cavity is uncommon. PATIENT CONCERN: We describe a 30-year-old man with a 2-month history of hoarseness, weight loss, and dyspnea. DIAGNOSIS: Magnetic resonance image (MRI) showed edema of the larynx with obliteration of the airway. Laryngoscopic examination described necrotic tissue in the glottis and larynx. The biopsy showed chronic, necrotizing laryngitis, with no granulomas, vasculitis, or atypical cells. The immunologic and microbiologic study was negative. Later, after immunosuppressive therapy, the patient presented erythema and diffuse enlargement of the right arm. MRI showed myositis of the biceps and brachial muscles. Infection was rule out, and direct microscopy showed an extensive muscle infiltration by mononuclear cells and abundant mitosis. Immunohistochemistry was positive for CD3, CD8, Ki 67 (90%), and CD56 compatible with extranodal NK/T cell lymphoma. INTERVENTIONS: The patient initially received immunosuppression treatments (corticoids, cyclofosfamide, and Rituximab) with relapsing episodes. When lymphoma was diagnosed, chemotherapy was started. OUTCOMES: The patient died during chemotherapy. LESSONS: Nasal-type, extranodal NK/T-cell lymphoma should be suspected even when there are no classical findings of neoplasms on histology. Immunohistochemistry is mandatory to rule it out.


Subject(s)
Laryngeal Neoplasms/diagnosis , Laryngitis/diagnosis , Larynx/pathology , Lymphoma, Extranodal NK-T-Cell/diagnosis , Muscle Neoplasms/diagnosis , Adult , Arm/diagnostic imaging , Biopsy , Chemoradiotherapy/methods , Chronic Disease/drug therapy , Diagnosis, Differential , Fatal Outcome , Humans , Laryngeal Neoplasms/complications , Laryngeal Neoplasms/pathology , Laryngeal Neoplasms/therapy , Laryngitis/etiology , Laryngitis/pathology , Laryngitis/therapy , Laryngoscopy , Larynx/diagnostic imaging , Lymphoma, Extranodal NK-T-Cell/complications , Lymphoma, Extranodal NK-T-Cell/pathology , Lymphoma, Extranodal NK-T-Cell/therapy , Magnetic Resonance Imaging , Male , Muscle Neoplasms/complications , Muscle Neoplasms/pathology , Muscle Neoplasms/therapy
20.
Sci Rep ; 11(1): 12479, 2021 06 14.
Article in English | MEDLINE | ID: mdl-34127765

ABSTRACT

The objective of this study is to assess the change in the normal MD elasticity using shear wave elastography (SWE) through measuring the middle deltoid (MD) elasticity in healthy participants at various arm abduction (with bilateral arms at 0 degrees abduction and 90 degrees active abduction) and analyzing the factors affecting normal MD elasticity. Mean shear wave velocity (SWV) of the MD in healthy right-handed participants were evaluated using SWE at different arm abduction, and potential factors (gender, MD thickness, age, body mass index) affecting MD elasticity were analyzed. Different arm abduction positions of each participant were as follows: (i) 0° abduction of bilateral arm (L0° and R0°), (ii) 90° active abduction of bilateral arm (L90° and R90°). Mean SWV was significantly higher at L90° than L0°, higher at R90° than R0°, higher at R0° than L0°, and higher at R90° than L90° (all P < 0.0001). SWV was significantly higher in males at both L0° (P < 0.05) and R0° (P < 0.01) than in females. Neither MD thickness, age nor body mass index influenced MD elasticity. Reference ranges of normal MD elasticity were 2.4-3.1 m/s in males and 2.2-2.9 m/s in females at L0° and 2.5-3.3 m/s in males and 2.4-3.2 m/s in females at R0°, and were 4.9-6.7 m/s at L90°, 5.2-7.1 m/s at R90° for both males and females. SWE is a feasible technique to assess normal MD elasticity at various arm abduction. Our results suggest that normal MD elasticity at L0°, R0°, L90°, and R90° with SWE are different. Moreover, these reference ranges may serve as quantitative baseline measurements for assessment of normal MD elasticity in the future.


Subject(s)
Arm/physiology , Deltoid Muscle/physiology , Elasticity Imaging Techniques , Elasticity/physiology , Movement , Adult , Aged , Arm/diagnostic imaging , Deltoid Muscle/diagnostic imaging , Feasibility Studies , Female , Healthy Volunteers , Humans , Male , Middle Aged , Reference Values , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...