Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 616
Filter
1.
J Vasc Surg ; 75(3): 1047-1053, 2022 03.
Article in English | MEDLINE | ID: mdl-34601044

ABSTRACT

OBJECTIVE: Arteriovenous grafts (AVGs) are frequently needed in hemodialysis (HD) patients with unsuitable superficial veins. First cannulation of standard arteriovenous grafts (sAVGs) still require about 2 weeks after implantation. Early cannulation arteriovenous grafts (eAVGs) were suggested to overcome this shortcoming. The present randomized study proposed to compare the clinical outcomes of sAVGs and eAVGs in HD patients. METHODS: The present single-center randomized clinical study recruited 477 HD patients indicated for AVG creation. They included 236 in the sAVG group and 241 in the eAVG group. Eligible patients were simply randomized and allocated to the studied groups using 1:1 allocation ratio. Blinding was secured using the sealed envelope technique. Enrolled patients were followed up for 12 months. The primary outcome in the present study was primary, primary assisted, and secondary patency rates at 12 months. Other outcome parameters included time to first cannulation, graft complications, and mortality. RESULTS: Comparison between the studied groups regarding the primary outcomes revealed no statistically significant differences. Primary patency rate was 65.7% and 68.0% (P = .58) at 6 months and 53.8% and 56.4% (P = .57) at 12 months in the sAVG and eAVG groups, respectively. Primary assisted patency rate was 70.8% and 69.7% (P = .8) in patients with sAVG and eAVG, whereas the reported rates at 12 months were 59.3% and 61.0% (P = .71), respectively. Secondary patency rate was 78.4% and 73.9% (P = .25) at 6 months and 67.8% and 69.7% (P = .65) at 12 months in the sAVG and eAVG groups, respectively. As expected, patients in the eAVG group experienced significantly earlier cannulation when compared with patients in the sAVG group (median, 3.0 days; range, 1.0-9.0 days vs 19.0 days; range, 15.0-22.0 days; P < .001). CONCLUSIONS: Patients in the eAVG group have comparable outcomes to those in the sAVG group at 12 months with the added advantage of earlier time to first cannulation.


Subject(s)
Arteriovenous Shunt, Surgical , Blood Vessel Prosthesis Implantation , Catheterization , Renal Dialysis , Adult , Arteriovenous Shunt, Surgical/adverse effects , Arteriovenous Shunt, Surgical/instrumentation , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Catheterization/adverse effects , Egypt , Female , Humans , Male , Middle Aged , Polytetrafluoroethylene , Prosthesis Design , Time Factors , Treatment Outcome , Vascular Patency
2.
J Vasc Surg ; 75(3): 1038-1046.e3, 2022 03.
Article in English | MEDLINE | ID: mdl-34601046

ABSTRACT

BACKGROUND: Percutaneous devices for creation of native arteriovenous fistulae offer an alternative to traditional open surgical techniques. The 4F WavelinQ EndoAVF System was developed as a lower profile alternative to facilitate access through smaller vessels and minimize access site complications; The current report is the original first experience of this device, assessing outcome in 120 patients followed for 6 months. METHODS: The use of the 4F WavelinQ system in three studies, EASE (32 patients), EASE-2 (24 patients), and the EU postmarket clinical follow-up study (64 patients) was aggregated and analyzed. Patients were followed with duplex ultrasound at discharge and follow-up visits at 1, 3, and 6 months. Primary, assisted primary, and secondary patency rates were evaluated as Kaplan-Meier estimates and standard errors. Time to maturity and time to successful cannulation were defined as the mean ± standard deviation days from the procedure in patients enrolled on dialysis. RESULTS: Procedural success was achieved in 116 patients (96.7%). Primary, assisted-primary, and secondary 6-month patency rates were 71.9% ± 4.5%, 80.7% ± 4.1%, and 87.8% ± 3.3%, respectively. Time to maturity averaged 41 ± 17 days. Time to successful cannulation averaged 68 ± 51 days. Device-related serious adverse events were reported in 3 of 120 patients (2.5%) and procedure-related serious adverse events occurred in 7 of 120 patients (5.8%). Arterial or venous access complications were not reported in any of the patients. Access circuit reinterventions were performed in 23 patients (19.2%), split between those performed for EndoAVF maturation (13/120 [10.8%]) and maintenance (11/120 [9.2%]). CONCLUSIONS: Percutaneous creation of native dialysis fistulae with the 4F WavelinQ EndoAVF System is safe and effective, with favorable durability and a low rate of serious complications and reinterventions through 6-month follow-up. Use of the 4F device allows for percutaneous fistula creation between the radial artery and radial vein or the ulnar artery and ulnar vein. These findings suggest that the 4F device is a useful percutaneous alternative to open surgical AVF or endovascular AVF with larger bore devices.


Subject(s)
Arteriovenous Shunt, Surgical/instrumentation , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Renal Dialysis , Renal Insufficiency, Chronic/therapy , Upper Extremity/blood supply , Adult , Aged , Aged, 80 and over , Arteriovenous Shunt, Surgical/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Clinical Trials as Topic , Female , Humans , Male , Middle Aged , Prospective Studies , Prosthesis Design , Radial Artery/surgery , Renal Insufficiency, Chronic/diagnosis , Renal Insufficiency, Chronic/physiopathology , Time Factors , Treatment Outcome , Ulnar Artery/surgery , Ultrasonography, Doppler, Duplex , Vascular Patency , Young Adult
3.
J Vasc Surg ; 75(1): 248-254, 2022 01.
Article in English | MEDLINE | ID: mdl-34314835

ABSTRACT

OBJECTIVE: To evaluate the outcomes of arteriovenous fistulae (AVF), created with VasQ external support device under standard clinical practice across three vascular access clinics. METHODS: This multinational, retrospective study evaluated prospectively collected clinical outcomes of both forearm and upper arm brachiocephalic AVF (BCAVF) created using the VasQ device. Fifty-one AVF patients were pooled from three different vascular access centers in Germany, Italy, and Spain. Postprocedure outcomes were assessed by flow measurement with ultrasound examination in all centers. Primary failure, usability, patency, and intervention rates during the study period were evaluated. RESULTS: Fifty-one VasQ devices were implanted during 37 forearm (36 radiocephalic and 1 ulnar-basilic AVF) and 14 BCAVF procedures. The study population comprised mostly males (73%) and Caucasians (82%), with a mean age of 62.5 years (range, 38-84 years) and mean body mass index of 29.2. One patient died owing to access-unrelated reasons, and one patient was lost to follow-up without AVF assessment after its creation. From the remaining 49, 3 patients had a follow-up of less than 4 weeks and were excluded from maturation, primary failure, and dialysis initiation analysis (because those factors could not be evaluated yet), leaving 46 patients in this evaluation. Maturation was achieved in 91% of patients. The primary failure rate was 9%. A primary patency rate of 77% was observed at 6, 12, and 18 months. The secondary patency rate was 91% at 6 months, and 85% at 12 months and 18 months. Both primary patency and secondary patency did not differ statistically when comparing forearm AVF with BCAVF (P > .25). Successful cannulation was achieved in 86% of patients (32/37) requiring dialysis with a median time from creation to cannulation of 46 days. Of those patients, the functional patency rate was 94%. Five patients underwent seven interventions to maintain or restore patency or functionality, with an overall rate of 0.248 interventions per patient-year. CONCLUSIONS: AVFs created with VasQ external support device demonstrated promising patency and functionality outcomes in multicentric real-world setting across the two most commonly used anatomic locations.


Subject(s)
Arteriovenous Shunt, Surgical/instrumentation , Renal Dialysis/methods , Vascular Patency , Adult , Aged , Aged, 80 and over , Brachial Artery/surgery , Female , Follow-Up Studies , Forearm/blood supply , Humans , Kidney Failure, Chronic/therapy , Male , Middle Aged , Prospective Studies , Radial Artery/surgery , Renal Dialysis/instrumentation , Retrospective Studies , Treatment Outcome
4.
Ther Apher Dial ; 26(1): 191-196, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34018667

ABSTRACT

This prospective study compared methods using both arterial and venous needles with back eyes with those using only arterial needle with back eye for arteriovenous fistula cannulation. Sixty-one patients receiving hemodialysis (HD) via an arteriovenous fistula were evaluated. All patients underwent arteriovenous fistula puncture using only arterial needle with back eye in first 3 months and both arterial and venous needles with back eyes in following 3 months. Arterial and venous pressures, blood flow velocities, total blood volume cleared, and Kt/V values were compared. Mean blood flow velocity, arterial pressure, Kt/V, and cleared total blood volume values were higher and venous pressure was lower in patients who underwent cannulation using both needles with back eyes than in those with only the arterial needle with back eye. For arteriovenous fistula cannulation, using both arterial and venous needles with back eyes provides adequate HD more successfully.


Subject(s)
Arteriovenous Shunt, Surgical/instrumentation , Arteriovenous Shunt, Surgical/methods , Needles , Punctures/instrumentation , Punctures/methods , Renal Dialysis/methods , Equipment Design , Female , Humans , Male , Middle Aged , Prospective Studies
5.
J Vasc Access ; 23(1): 42-49, 2022 Jan.
Article in English | MEDLINE | ID: mdl-33213273

ABSTRACT

OBJECTIVE: It is unclear whether tapered arteriovenous grafts (AVGs) are superior to non-tapered AVGs when it comes to preventing upper extremity ischemic steal syndrome. We aimed to evaluate the outcomes of tapered and non-tapered AVGs using systematic review and meta-analysis. METHODS: A literature search was systemically performed to identify all English publications from 1999 to 2019 that directly compared the outcomes of upper extremity tapered and non-tapered AVGs. Outcomes evaluated were the primary patency at 1-year (number of studies (n) = 4), secondary patency at 1-year (n = 3), and risk of ischemic steal (n = 5) and infection (n = 4). Effect sizes of individual studies were pooled using random-effects model, and between-study variability was assessed using the I2 statistic. RESULTS: Of 5808 studies screened, five studies involving 4397 patients have met the inclusion criteria and included in the analysis. Meta-analyses revealed no significant difference for the risk of ischemic steal syndrome (pooled odds ratio (OR) 0.92, 95% Confidence Incidence (CI) 0.29-2.91, p = 0.89, I2 = 48%) between the tapered and non-tapered upper extremity AVG. The primary patency (OR 1.33, 95% CI 0.93-1.90, p = 0.12, I2 = 10%) and secondary patency at 1-year (OR 1.49, 95% CI 0.84-2.63, p = 0.17, I2 = 13%), and rate of infection (OR 0.62, 95% CI 0.30-1.27, p = 0.19, I2 = 29%) were also similar between the tapered and non-tapered AVG. CONCLUSIONS: The risk of ischemic steal syndrome and patency rate are comparable for upper extremity tapered and non-tapered AVGs. This meta-analysis does not support the routine use of tapered graft over non-tapered graft to prevent ischemic steal syndrome in upper extremity dialysis access. However, due to small number of studies and sample sizes as well as limited stratification of outcomes based on risk factors, future studies should take such limitations into account while designing more robust protocols to elucidate this issue.


Subject(s)
Arteriovenous Shunt, Surgical , Blood Vessel Prosthesis Implantation , Renal Dialysis , Arteriovenous Shunt, Surgical/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Graft Occlusion, Vascular/etiology , Humans , Retrospective Studies , Risk Factors , Upper Extremity , Vascular Patency
6.
J Vasc Access ; 23(1): 75-80, 2022 Jan.
Article in English | MEDLINE | ID: mdl-33267674

ABSTRACT

BACKGROUND: In patients without suitable vasculature for autologous arteriovenous fistula, vascular access using a prosthetic graft is an option for hemodialysis. Gore® ACUSEAL Vascular graft is an early cannulation arteriovenous graft (AVG) that allows early puncture within 24 h after surgery. We aimed to report the outcomes of using this graft in patients from a single center. METHODS: This study included 113 patients who underwent surgery for a new AVG using ACUSEAL, between December 2015 and December 2017, and were followed up. The primary outcomes were primary patency, assisted-primary patency, and secondary patency. Secondary outcomes were postoperative complications such as graft infection and steal syndrome. RESULTS: Of the 113 patients, 60 were male and 53 were female. The average age was 74.4 ± 10.7 years. We could cannulate 69.1% of patients within 24 h. The average follow-up period was 20.1 ± 10.8 months. The primary patency rates after 3 months, 6 months, and 1 year were 76.2%, 60.4%, and 33.8%, respectively. The assisted-primary patency rates after 3 months, 6 months, and 1 year were 88.8%, 73.2%, and 58.9%, respectively. The secondary patency rates after 3 months, 6 months, and 1 year were 100%, 100%, and 98.8%, respectively. Fourteen patients (12.4%) developed graft infection and two patients (1.8%) developed steal syndrome. CONCLUSION: In our study, ACUSEAL showed satisfactory patency and acceptable complication rates in the short to medium term, similar to previous studies. ACUSEAL is beneficial for surgeons who are familiar with using AVG and for medical staff who control bleeding after dialysis. However, due to the large outer diameter of the graft, surgical wounds might become dehiscent, and careful designing of the subcutaneous graft route is necessary. It might be possible to reduce the rate of graft infection by planning the site and skin incision.


Subject(s)
Arteriovenous Shunt, Surgical , Blood Vessel Prosthesis Implantation , Renal Dialysis , Aged , Aged, 80 and over , Arteriovenous Shunt, Surgical/instrumentation , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Female , Humans , Japan , Male , Middle Aged , Time Factors , Treatment Outcome
7.
Am J Kidney Dis ; 78(4): 520-529.e1, 2021 10.
Article in English | MEDLINE | ID: mdl-33662481

ABSTRACT

RATIONALE & OBJECTIVE: Percutaneous arteriovenous fistulas (AVF) are created by establishing a proximal forearm anastomosis and offer a safe and reliable vascular access. This study compares the Ellipsys percutaneous AVF with a proximal forearm Gracz-type surgical AVF, chosen for comparison as it is constructed at the same anatomical site. STUDY DESIGN: Retrospective study of prospectively collected clinical data. SETTING & PARTICIPANTS: All vascular access procedures conducted during a 34-month period were reviewed. The study groups comprised 89 percutaneous AVFs and 69 surgical AVFs. EXPOSURE: Percutaneous or surgical AVF placement. OUTCOME: AVF patency, function, and complications. ANALYTICAL APPROACH: Patency rates for each AVF group were evaluated by competing risk survival analysis using a cumulative incidence function. Association of primary, primary assisted, and secondary patency with the AVF groups was examined by Cox proportional hazard models. RESULTS: Technical success was 100% for both groups. Average procedure times were 14 minutes for percutaneous AVFs and 74 minutes for surgical AVFs (P < 0.001). Proximal radial artery (PRA) was used in all percutaneous AVF cases. Inflow for surgical AVFs included radial (30%), ulnar (12%), and brachial (58%) arteries. Outflow veins for both groups were the cephalic and/or basilic veins. Access flow volumes, times to maturation, and overall numbers of interventions per patient-year were not significantly different. Cumulative incidence of primary patency failure at 12 months was lower for surgical AVF (47% vs 64%, P = 0.1), but secondary patency failure was not different between groups (20% vs 12%, P = 0.3). PRA surgical AVFs had similar primary patency (65% vs 64%, P = 0.8) but higher secondary patency failure rates than percutaneous AVFs at 12 months (34% vs 12%, P = 0.04). LIMITATIONS: Retrospective study with a relatively short follow-up period, and not all patients required hemodialysis at the end of study. CONCLUSIONS: Both percutaneous and surgical AVFs demonstrated high rates of technical success and secondary patency. Percutaneous AVFs required shorter procedure times. The rate of intervention was similar. When a distal radial artery AVF is not feasible, percutaneous AVF might offer an appropriate procedure for creating a safe and functional access, maintaining further proximal forearm surgical AVF creation options.


Subject(s)
Arteriovenous Shunt, Surgical/methods , Forearm/blood supply , Kidney Failure, Chronic/therapy , Renal Dialysis/methods , Adult , Aged , Aged, 80 and over , Arteriovenous Shunt, Surgical/instrumentation , Brachial Artery/physiology , Female , Follow-Up Studies , Humans , Kidney Failure, Chronic/diagnosis , Male , Middle Aged , Radial Artery/physiology , Renal Dialysis/instrumentation , Retrospective Studies , Ulnar Artery/physiology , Vascular Patency/physiology
9.
J Vasc Surg ; 74(1): 327-333.e2, 2021 07.
Article in English | MEDLINE | ID: mdl-33548433

ABSTRACT

OBJECTIVE: Creation of good long-term arteriovenous access is essential in patients requiring hemodialysis for end-stage renal failure. However, arteriovenous grafts or fistulae can be complicated by infection that may require emergency surgery. For infections that involve the brachial artery anastomosis, or if total graft explantation is indicated, brachial artery repair or reconstruction is often required. An alternative management strategy would be brachial artery ligation (BAL). We performed a systematic review to evaluate the outcomes of BAL that has been performed for infected arteriovenous grafts or fistulae. METHODS: A thorough literature search was conducted using various electronic databases. We included articles that reported outcomes of BAL performed for infected arteriovenous grafts or fistulae. The primary outcome was the incidence of upper limb ischemia after BAL. Secondary outcomes were the need for urgent revascularization, need for upper limb amputation, and incidence of postoperative neurological deficit after BAL. RESULTS: A total of five studies with a total of 125 patients were included in our systematic review. BAL was performed for infected arteriovenous grafts or fistulae for all studies. Follow-up period ranged from 1 to 27 months. The incidence of upper limb ischemia after BAL was low. Only a single study reported three patients who developed upper limb ischemia. Two patients required urgent revascularization, and one patient required forearm amputation after proximal ligation. All studies reported clearance of infection with no recurrence. CONCLUSIONS: Distal BAL may be performed safely for patients with infected arteriovenous fistulae or grafts with low risk of upper limb ischemia, postoperative neurological deficit, and recurrent infection.


Subject(s)
Arteriovenous Shunt, Surgical/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis/adverse effects , Brachial Artery/surgery , Prosthesis-Related Infections/surgery , Renal Dialysis , Adult , Aged , Aged, 80 and over , Arteriovenous Shunt, Surgical/instrumentation , Blood Vessel Prosthesis Implantation/instrumentation , Female , Humans , Ligation , Male , Middle Aged , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/etiology , Reinfection , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , Young Adult
10.
J Vasc Surg ; 74(1): 209-216, 2021 07.
Article in English | MEDLINE | ID: mdl-33548442

ABSTRACT

OBJECTIVE: The aim of the present study was to compare the results between percutaneous arteriovenous fistulas (p-AVFs) created with the Ellipsys device (Ellipsys Vascular Access System; Avenu Medical, San Juan Capistrano, Calif) and surgical arteriovenous fistulas (s-AVFs). METHODS: A single-center retrospective comparative study of the first 107 patients who had undergone p-AVF creation with the Ellipsys system from May 2017 to May 2018 with an equal number of consecutive patients who had undergone s-AVF creation in our center during the same period. The primary endpoints included the maturation and patency rates. The secondary endpoints were reintervention, risk of infection, and the incidence of steal syndrome and aneurysm formation. RESULTS: The demographic, hypertension, and diabetes data were similar for both groups. The only difference between the two groups was that more p-AVF patients had already been receiving hemodialysis (61% vs 47%; P < .05). The p-AVFs showed superior maturation rates at 6 weeks (65% vs 50%; P = .01). The primary patency rates were greater for the s-AVFs at 12 months (86% vs 61%; P < .01). However, primary patency was comparable between the two groups at 24 months (52% vs 55%; P = .48). No significant difference was found in the secondary patency rates at 12 (90% vs 91%) and 24 (88% vs 91%) months. At the 2-year follow-up point, the rate of percutaneous reintervention was similar; however, the s-AVFs had required more frequent surgical revision (36% vs 17%; P = .01). Issues with wound healing and infection were also more frequent with s-AVFs (9% vs 0.9%; P < .01). CONCLUSIONS: Fistulas created percutaneously with the Ellipsys system showed superior maturation rates and similar patency with s-AVFs created in an experienced high-volume vascular surgery practice. p-AVFs had a lower risk of wound healing issues, infection, and surgical revision. Larger, prospective, randomized multicenter studies are needed to confirm these findings.


Subject(s)
Arteriovenous Shunt, Surgical , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Renal Dialysis , Aged , Aneurysm/etiology , Aneurysm/therapy , Arteriovenous Shunt, Surgical/adverse effects , Arteriovenous Shunt, Surgical/instrumentation , Blood Vessel Prosthesis/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Female , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/physiopathology , Graft Occlusion, Vascular/therapy , Humans , Ischemia/etiology , Ischemia/physiopathology , Ischemia/therapy , Male , Middle Aged , Prosthesis-Related Infections/etiology , Prosthesis-Related Infections/therapy , Retreatment , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , Vascular Patency
11.
Ann Vasc Surg ; 74: 271-280, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33549799

ABSTRACT

BACKGROUND: Recently, there has been an abundance of encouraging data regarding the creation of percutaneous arteriovenous fistulas. Despite promising data regarding their clinical maturation, a paucity of data exists which provides direct comparison between percutaneously created AVFs (pAVF) and open surgically created AVFs (sAVF). This study has 2 primary objectives: First, to compare clinical outcomes of pAVFs to sAVFs, with emphasis on clinical maturation and frequency of postoperative interventions to facilitate maturation. Second, to contribute toward the evidence-based incorporation of the pAVF procedure into the hemodialysis access algorithm. METHODS: A single-center retrospective review was performed on all consecutive patients undergoing surgically created brachiocephalic arteriovenous fistula (BC-AVF, sAVF group) from January 1, 2018 to December 31, 2018 and Ellipsys-created percutaneous arteriovenous fistula (pAVF group) from January 1, 2019 to December 31, 2019. Comparative analysis between groups was performed. RESULTS: A total of 24 patients underwent Ellipsys-created pAVF with mean age of 56.7 ± 22.6 years (12 males [50%], 12 females [50%]) and 62 patients underwent surgically created BC-AVF with mean age of 62.5 ± 13.2 years (32 males [52%], 30 females [48%]). Both the pAVF and sAVF groups had comparable mean operating times (60 ± 40 vs. 56 ± 25 min, P = 0.67) and frequency of procedural technical success (23 [96%] vs. 62 [100%], P = 0.28), respectively. The pAVF group had a lower clinical maturation rate (12 [52%] vs. 54 [87%], P = 0.003) and a higher primary failure rate (9 [39%] vs. 6 [10%], P = 0.003) when compared to the sAVF group. The pAVF group had an increased overall rate of undergoing a postoperative intervention (18 [78%] vs. 13 [21%], P< 0.001), as well as an increased number of total postoperative interventions (1.1 ± 0.9 vs. 0.3 ± 0.6 interventions, P< 0.001) compared to the sAVF group. Percutaneous transluminal angioplasty of the juxta anastomotic segment was the most prevalent postoperative intervention performed in the pAVF group and occurred at a significantly increased frequency when compared to the sAVF group rate (13 [57%] vs. 5 [8%], P< 0.001). CONCLUSIONS: In our single-center retrospective review, patients undergoing Ellipsys-created pAVF in the first year following introduction of percutaneous endovascular had inferior rates of clinical maturation and underwent more postoperative interventions when compared to historical patients undergoing surgically created BC-AVF. Outcome discrepancies compared to previously reported Ellipsys data demonstrate a need for further studies examining the practical translatability of the pAVF.


Subject(s)
Arteriovenous Shunt, Surgical , Brachial Artery/surgery , Endovascular Procedures , Renal Dialysis , Upper Extremity/blood supply , Adult , Aged , Arteriovenous Shunt, Surgical/adverse effects , Arteriovenous Shunt, Surgical/instrumentation , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Female , Humans , Male , Middle Aged , New Mexico , Operative Time , Postoperative Complications/etiology , Program Evaluation , Retrospective Studies , Time Factors , Treatment Outcome , Vascular Patency
12.
J Vasc Access ; 22(2): 166-172, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32026749

ABSTRACT

BACKGROUND: The VasQTM device was designed to improve the outcome of arteriovenous fistulae by optimizing the hemodynamics of the flow in the juxta-anastomotic region of the arteriovenous fistulae through tailored external support. The aim of the study was to evaluate the impact of the VasQ on outcome of radiocephalic arteriovenous fistulae in a real-world setting. METHODS: This was a single-center, retrospective analysis of patients with either fistula creation before or after dialysis initiation with implantation of the VasQ device during creation of end-to-side radiocephalic arteriovenous fistulae between June 2018 and May 2019. The flow rate and vein diameter were evaluated intraoperatively, at discharge within 48 h postprocedure and at a follow-up of 1, 3, 6, 9, and 12 months. RESULTS: Thirty-three VasQ devices were implanted during 33 radiocephalic arteriovenous fistula procedures. The study population comprised mostly of men, with an average age of 66 years. Mean intraoperative flow was 428 mL/min (range: 130-945). All patients were discharged with patent arteriovenous fistulae and mean fistula flow of 740 mL/min (range: 230-1300 mL/min). The primary patency was 100% and 79% at 3 and 6 months, respectively. Cumulative/secondary patency was 100% and 90% at 3 and 6 months, respectively. CONCLUSION: Data presented here suggest that the VasQ device has the potential to provide benefit to the functionality of radiocephalic arteriovenous fistulae.


Subject(s)
Arteriovenous Shunt, Surgical/instrumentation , Radial Artery/surgery , Renal Dialysis , Upper Extremity/blood supply , Vascular Patency , Adult , Aged , Aged, 80 and over , Arteriovenous Shunt, Surgical/adverse effects , Female , Germany , Humans , Male , Middle Aged , Radial Artery/diagnostic imaging , Radial Artery/physiopathology , Regional Blood Flow , Retrospective Studies , Time Factors , Treatment Outcome , Young Adult
13.
J Vasc Access ; 22(3): 470-474, 2021 May.
Article in English | MEDLINE | ID: mdl-32772777

ABSTRACT

BACKGROUND: More than 400,000 Americans require dialysis, and many receive it via a prosthetic arteriovenous graft. Infection of these grafts is rare, but associated with significant morbidity and mortality. The gold standard is total graft excision with arteriotomy closure. This was previously done with autologous vein, but bovine tissue offers a reasonable alternative. The objective of this article is to evaluate a community hospital experience with bovine tissue arterial repair after total graft excision of infected prosthetic arteriovenous graft. METHODS: A retrospective review was performed of all cases of infected prosthetic arteriovenous graft removal with bovine tissue arterial repair was performed. Thirteen cases were identified. Presentation, location of graft, and causative organism were reviewed; outcomes including reoperation and mortality were recorded. RESULTS: Of the 13 patients, 12 (92%) had positive cultures of the graft, bloodstream, or wound. Methicillin-resistant Staphylococcus aureus was the most commonly isolated organism (54%). There were two unplanned reoperations including hematoma drainage and wound debridement within the first year. Over the 1-year follow-up period, 1 patient died for a mortality of 8%. There were no re-infections during follow-up. DISCUSSION: Prosthetic arteriovenous graft infection remains a difficult challenge and is associated with significant morbidity and mortality. It presents in a variety of ways, including within an old thrombosed graft. Over the last several years, the causative organism has increasingly become drug resistant. Treatment with total graft excision requires arteriotomy closure, and for this bovine tissue has been demonstrated to be a viable option.


Subject(s)
Arteriovenous Shunt, Surgical/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis/adverse effects , Carotid Arteries/transplantation , Device Removal , Pericardium/transplantation , Prosthesis-Related Infections/surgery , Renal Dialysis , Adult , Aged , Animals , Arteriovenous Shunt, Surgical/instrumentation , Arteriovenous Shunt, Surgical/mortality , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Cattle , Databases, Factual , Device Removal/adverse effects , Device Removal/mortality , Female , Heterografts , Humans , Male , Middle Aged , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/microbiology , Prosthesis-Related Infections/mortality , Retrospective Studies , Time Factors , Treatment Outcome
14.
J Vasc Surg ; 73(3): 999-1004, 2021 03.
Article in English | MEDLINE | ID: mdl-33068764

ABSTRACT

OBJECTIVE: The Food and Drug Administration recently approved two percutaneous arteriovenous fistula creation systems: the Ellipsys vascular access (EL) system and WavelinQ EndoAVF (WQ) system. Although the initial clinical trials of each system have demonstrated a high success rate, little detail on anatomic suitability was provided. We sought to determine the real-world applicability of the EL and WQ systems by studying them in a single representative cohort. METHODS: All patients receiving a first-time arteriovenous access consultation at a single Veterans Affairs institution underwent extensive vein mapping of the bilateral upper extremities. Anatomic suitability was assessed in accordance with the manufacturer's instructions for use (IFU), and clinical usability was determined using additional published anatomic guidelines. The suitability for radiocephalic fistula (RCF) creation was also assessed. To estimate how often these systems would be used in practice, a clinical algorithm was created, with a preference for RCF creation, followed by percutaneous arteriovenous fistula (pAVF) creation, surgical fistula creation at the elbow, and, finally, graft placement. RESULTS: During the study period, 116 upper extremities were measured in 58 male patients. Per the IFU, the rate of extremity suitability was 93% and 52% for the WQ and EL systems, respectively (P < .0001). In the same population, 32% of the extremities had acceptable anatomy for RCF creation. The overall clinical usability of these systems using more recent published guidelines was 55% for the WQ system and 44% for the EL system (P = .09). The usability of both pAVF systems was most limited by the size of the deep perforating cubital vein. The proximity of the antecubital perforator vein and proximal radial artery additionally limited EL usability. Based on the clinical algorithm, initial access creation would have been RCF creation for 31% of the cohort, followed by the WQ (32%), the EL (23%), surgical fistula creation at the elbow (18%), and graft placement (17%). CONCLUSIONS: Anatomic suitability was greater for WQ than for EL when considering only the IFU. Once the full requirements for pAVF creation were considered, we found no significant differences in usability between the two systems. Anatomic analysis showed that pAVF creation can constitute a substantial part of a hemodialysis access practice.


Subject(s)
Arteriovenous Shunt, Surgical/instrumentation , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Renal Dialysis , Upper Extremity/blood supply , Aged , Algorithms , Arteriovenous Shunt, Surgical/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Clinical Decision Rules , Clinical Decision-Making , Humans , Male , Middle Aged , Predictive Value of Tests , Prosthesis Design , Retrospective Studies , Treatment Outcome , Ultrasonography , United States , United States Department of Veterans Affairs
15.
J Vasc Access ; 22(2): 299-303, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32597355

ABSTRACT

BACKGROUND: The first arteriovenous fistulas were created at the wrist more than 60 years ago. Basic surgical construction techniques remain unchanged with mobilization and repositioning of the vessels followed by a sutured anastomosis. We used the Ellipsys device to construct percutaneous radiocephalic-arteriovenous fistulas at the wrist and report the results. METHODS: Data were reviewed retrospectively for all patients who had a percutaneous radiocephalic-arteriovenous fistula created during a 6-month period. Each individual underwent ultrasound vessel mapping in addition to physical examination. When a radiocephalic-arteriovenous fistula was feasible and a communicating vein ⩾ 2 mm in diameter was noted in the distal forearm along with a radial artery ⩾ 2 mm, a percutaneous radiocephalic-arteriovenous fistula was considered and reviewed with the patient. RESULTS: Four individuals met the criteria to consider a percutaneous radiocephalic-arteriovenous fistula and all elected to have the procedure performed. Ages were 54-85 years. Three were diabetic and one was female. All percutaneous radiocephalic-arteriovenous fistulas were technically successful. Two individuals had not yet started dialysis therapy. Successful and repetitive cannulation for the two individuals with catheters was initiated at 4 and 8 weeks post procedure. The two pre-dialysis patients had physiologic arteriovenous fistula maturation (6 mm vein diameter and >500 mL/min flow) at 4 and 12 weeks. There were no procedural or late complications and none required intervention. Follow-up was 8-23 months (mean 16 months). CONCLUSION: The success of these percutaneous radiocephalic-arteriovenous fistulas suggests that use of the Ellipsys device will be applicable at the wrist in selected patients where appropriate vessel sizes and configurations are found.


Subject(s)
Arteriovenous Shunt, Surgical , Blood Vessel Prosthesis Implantation , Radial Artery/surgery , Renal Dialysis , Wrist/blood supply , Aged , Aged, 80 and over , Arteriovenous Shunt, Surgical/adverse effects , Arteriovenous Shunt, Surgical/instrumentation , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Female , Humans , Male , Middle Aged , Radial Artery/diagnostic imaging , Radial Artery/physiopathology , Retrospective Studies , Treatment Outcome , Vascular Patency
16.
J Vasc Access ; 22(2): 238-242, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32597359

ABSTRACT

OBJECTIVE: We evaluate the creation of a percutaneous proximal radial artery-radial vein arteriovenous fistula with Ellipsys® instead of the usual first-stage brachial artery fistula prior to a second-stage brachial vein elevation, in patients with inadequate cephalic and basilic veins. METHODS: Single center study of eight patients (six males, mean = 54 years) who underwent a two-stage brachial vein elevation procedure between May 2017 and October 2019. Inclusion criteria were life expectancy > 6 months, patent brachial and proximal radial artery (>2 mm in diameter) absent/inadequate cephalic and basilic veins, existence of a brachial vein >3 mm in diameter, and in continuity with a proximal radial vein > 2 mm in diameter. RESULTS: Technical success was 100%. Four patients required angioplasty of a juxta-anastomotic stenosis, accounting for a 6-month primary and secondary patency rates were 68% and 100%, respectively. Access flow averaged 982 mL/min (range 768-1586) at final follow-up evaluation. There were no significant adverse events related to the procedures. All fistulae were elevated at 4-12 (mean: 8) weeks post creation and were successfully cannulated with two needles after healing was completed (2-4 weeks after elevation). No patients developed hand ischemia or arm edema. CONCLUSIONS: Percutaneous creation of a proximal radial artery-radial vein fistula followed by brachial vein elevation is a safe and reliable option for autogenous access creation in patients with inadequate cephalic or basilic veins. Minimally invasive radial artery inflow and longer available length of the targeted brachial vein available for elevation are the main advantages in skilled hands.


Subject(s)
Arteriovenous Shunt, Surgical , Blood Vessel Prosthesis Implantation , Brachial Artery/surgery , Renal Dialysis , Upper Extremity/blood supply , Veins/surgery , Adult , Aged , Arteriovenous Shunt, Surgical/adverse effects , Arteriovenous Shunt, Surgical/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Brachial Artery/diagnostic imaging , Brachial Artery/physiopathology , Databases, Factual , Female , Humans , Male , Middle Aged , Regional Blood Flow , Retrospective Studies , Treatment Outcome , Vascular Patency , Veins/diagnostic imaging , Veins/physiopathology
17.
Ann Vasc Surg ; 71: 200-207, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32768531

ABSTRACT

BACKGROUND: Surgical resection could be an eradication treatment for patients with infected hemodialysis arteriovenous grafts (AVGs). This study aimed to investigate the outcomes of 3 surgical methods, including total resection, subtotal resection, and revision. METHODS: The patients who underwent surgical excision of infected AVGs performed at a single center from August 2012 to March 2019 were retrospectively analyzed. The following 3 surgical methods were used in our study: revision, subtotal resection, and total resection. Patients' demographics, medical history, perioperative details, reconstruction time, and follow-up data were collected. The outcomes including perioperative complications (within 30 days), mortality, reinfection rate of AVGs, with new access reconstruction or not, and the outcomes between reconstruction and nonreconstruction in the follow-up period were evaluated. RESULTS: Forty-one patients had infected AVGs in our study. Patients' mean age was 62 years, and 65.9% of the patients were female. The mean duration from the time of diagnosis to the operation was 14.4 days. Signs and symptoms at presentation included fever (51.2 %), swelling (43.9%), pain (58.5%), erythematous change (92.7%), and more severe features, such as altered consciousness (14.6%) and hypotension (12.2%). The pathological changes in the infected grafts included bleeding (29.3%), pus formation (73.2%), pseudoaneurysm (26.8%), and graft exposure (17.1%). Wound and graft cultures revealed an infectious etiology with fungi (7.3%), Pseudomonas aeruginosa (12.2%), Enterococcus spp. (2.4%), and Staphylococcus spp. (58.5%), with methicillin-resistant Staphylococcus aureus accounting for only 7.3%. Total resection, subtotal resection, and revision surgery were performed in 17.1%, 63.4%, and 19.5% of patients, respectively. Seven patients with complications required reoperation (17.1%), and adhesion ileus and hospital-acquired pneumonia occurred in only 2.4% and 7.3% of patients, respectively. During follow-up, most patients (82.9%) had reconstruction of the peripheral hemodialysis access with mean time of 64.3 (range: 21-92) days; mean time of use of new access was 90.5 days; and mean time of removal of catheter was about 106.3 days. Mortality rates in patients without and with reconstructed AV access during follow-up were 50% and 18%, respectively (P < 0.004). Eight cases (19.5%) had recurrence of AV access infections during follow-up; of these, 2 had revision surgery and 6 had subtotal resection. However, no patient with total resection had recurrent infections. CONCLUSIONS: The total resection group had no recurrent infection compared to the subtotal and revision groups. In addition, patients with reconstruction of peripheral hemodialysis access had a low mortality rate during the follow-up period.


Subject(s)
Arteriovenous Shunt, Surgical/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis/adverse effects , Device Removal , Prosthesis-Related Infections/surgery , Renal Dialysis , Arteriovenous Shunt, Surgical/instrumentation , Arteriovenous Shunt, Surgical/mortality , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Device Removal/adverse effects , Device Removal/mortality , Female , Humans , Male , Middle Aged , Postoperative Complications/therapy , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/microbiology , Prosthesis-Related Infections/mortality , Recurrence , Reoperation , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
18.
J Vasc Access ; 22(3): 475-479, 2021 May.
Article in English | MEDLINE | ID: mdl-32370648

ABSTRACT

Currently, there is no vascular access that possesses all ideal qualities for hemodialysis access, but attributes particularly lacking include: ease of identification (cannulation zone), ease of access, resistance to stenosis, durable to repetitive cannulation, resistance to infection, resistance to acute needle-related injuries, and instant hemostasis. The overall value of these attributes could be appreciated in the reduction of complications (patient burden and suffering, which can also result in increased healthcare costs), and improved safety and durability. In this case report, we present a novel hemodialysis access graft that has the potential to provide the following benefits: it is designed to be self-sealing and immediately usable post implant, easy to identify, easy to access, has more durable cannulation zones, and protects from needle-related injuries. This case report describes the first-in-man use of this novel graft technology to replace a giant, thrombotic, and difficult-to-access arteriovenous fistula to provide the patient with a potentially safer and more durable access that does not require placement of a bridging dialysis catheter. This single-patient experience suggests that implantation and function of this novel graft as a hemodialysis access is feasible in a human subject with end-stage renal disease, and it suggests that the novel properties (i.e. immediate use, easy identification, easy use, cannulation zone durability, and protection from needle-related injuries) of this graft seem to function as intended.


Subject(s)
Arteriovenous Shunt, Surgical/instrumentation , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Catheterization , Kidney Failure, Chronic/therapy , Renal Dialysis , Humans , Kidney Failure, Chronic/diagnosis , Male , Middle Aged , Prosthesis Design , Treatment Outcome , Vascular Patency
19.
J Vasc Surg ; 73(3): 1007-1015, 2021 03.
Article in English | MEDLINE | ID: mdl-32442609

ABSTRACT

OBJECTIVE: A patient's body mass index (BMI) can affect both perioperative and postoperative outcomes across all surgical specialties. Given that obesity and end-stage renal disease are growing in prevalence, we aimed to evaluate the association between BMI and outcomes of upper extremity arteriovenous (AV) access creation. METHODS: A retrospective single-institution review was conducted for AV access creations from 2014 to 2018. Patient demographics, comorbidities, and AV access details were recorded. BMI groups were defined as normal weight (18.5-24.9 kg/m2), overweight (25-29.9 kg/m2), obese (30-39.9 kg/m2), and morbidly obese (>40 kg/m2). Perioperative complications and long-term outcomes including access maturation (defined as access being used for hemodialysis or the surgeon's judgment that access was ready for use in patients not yet on hemodialysis), occlusion, and reintervention were evaluated. RESULTS: A total of 611 upper extremity AV access creations were performed on patients who were normal weight (29.6%), overweight (31.3%), obese (29.6%), and morbidly obese (9.5%). Access type included brachiocephalic (43.2%), brachiobasilic (25.5%), and radiocephalic (14.2%) fistulas and AV grafts (14.2%). Median age was 60.9 years, and 59.6% were male. Univariable analysis showed no difference between BMI groups for perioperative steal, hematoma, home discharge, or 30-day primary patency. Freedom from reintervention at 2 years on Kaplan-Meier analysis differed by BMI (44.5% ± 4.6% normal weight, 29% ± 3.8% overweight, 39.8% ± 4.3% obese, 34.7% ± 8% morbidly obese; P = .041). There was no difference in 2-year freedom from new access creation or survival. AV access maturity within 180 days differed between BMI groups (74.3% normal weight, 66% overweight, 65.7% obese, 46.6% morbidly obese; P < .001). On multivariable analysis, failure to mature within 180 days was associated with overweight (odds ratio [OR], 1.93; 95% confidence interval [CI], 1.14-3.29; P = .002), obese (OR, 2.12; 95% CI, 1.19-3.47; P = .009), and morbidly obese (OR, 3.68; 95% CI, 1.85-7.3; P < .001) relative to normal weight BMI. AV access reintervention was associated with overweight (hazard ratio [HR], 1.83; 95% CI, 1.34-2.5), obese (HR, 1.56; 95% CI, 1.12-2.16), and morbidly obese (HR, 1.69; 95% CI, 1.1-2.58; P = .02) relative to normal weight BMI. BMI was not independently associated with long-term readmission or survival. CONCLUSIONS: Obesity is associated with higher rates of AV access failure to mature and reintervention. Surgeons performing access creation on obese patients must consider this for planning and setting expectations. Weight loss assistance may need to be incorporated into treatment algorithms.


Subject(s)
Arteriovenous Shunt, Surgical/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Body Mass Index , Obesity/complications , Renal Dialysis , Upper Extremity/blood supply , Adult , Aged , Aged, 80 and over , Arteriovenous Shunt, Surgical/instrumentation , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Comorbidity , Female , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/therapy , Hematoma/etiology , Hematoma/therapy , Humans , Ischemia/etiology , Ischemia/therapy , Male , Middle Aged , Obesity/diagnosis , Patient Readmission , Retreatment , Retrospective Studies , Risk Assessment , Risk Factors , Severity of Illness Index , Time Factors , Treatment Outcome , Vascular Patency
20.
J Vasc Surg ; 73(2): 581-587, 2021 02.
Article in English | MEDLINE | ID: mdl-32473345

ABSTRACT

OBJECTIVE: Immediate-access arteriovenous grafts (IAAVGs), or early cannulation arteriovenous grafts (AVGs), are more expensive than standard grafts (sAVGs) but can be used immediately after placement, reducing the need for a tunneled dialysis catheter (TDC). We hypothesized that a decrease in TDC-related complications would make IAAVGs a cost-effective alternative to sAVGs. METHODS: We constructed a Markov state-transition model in which patients initially received either an IAAVG or an sAVG and a TDC until graft usability; patients were followed through multiple subsequent access procedures for a 60-month time horizon. The model simulated mortality and typical graft- and TDC-related complications, with parameter estimates including probabilities, costs, and utilities derived from previous literature. A key parameter was median time to TDC removal after graft placement, which was studied under both real-world (7 days for IAAVG and 70 days for sAVG) and ideal (no TDC placed with IAAVG and 1 month for sAVG) conditions. Costs were based on current Medicare reimbursement rates and reflect a payer perspective. Both microsimulation (10,000 trials) and probabilistic sensitivity analysis (10,000 samples) were performed. The willingness-to-pay threshold was set at $100,000 per quality-adjusted life-year (QALY). RESULTS: IAAVG placement is a dominant strategy under both real-world ($1201.16 less expensive and 0.03 QALY more effective) and ideal ($1457.97 less expensive and 0.03 QALY more effective) conditions. Under real-world parameters, the result was most sensitive to the time to TDC removal; IAAVGs are cost-effective if a TDC is maintained for ≥23 days after sAVG placement. The mean catheter time was lower with IAAVG (3.9 vs 8.7 months; P < .0001), as was the mean number of access-related infections (0.55 vs 0.74; P < .0001). Median survival in the model was 29 months. Overall mortality was similar between groups (76.3% vs 76.7% at 5 years; P = .33), but access-related mortality trended toward improvement with IAAVG (6.1% vs 6.8% at 5 years; P = .052). CONCLUSIONS: The Markov decision analysis model supported our hypothesis that IAAVGs come with added initial cost but are ultimately cost-saving and more effective. This apparent benefit is due to our prediction that a decreased number of catheter days per patient would lead to a decreased number of access-related infections.


Subject(s)
Arteriovenous Shunt, Surgical/economics , Blood Vessel Prosthesis Implantation/economics , Blood Vessel Prosthesis/economics , Health Care Costs , Renal Dialysis/economics , Arteriovenous Shunt, Surgical/adverse effects , Arteriovenous Shunt, Surgical/instrumentation , Arteriovenous Shunt, Surgical/mortality , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Catheterization/economics , Clinical Decision-Making , Cost-Benefit Analysis , Decision Support Techniques , Humans , Markov Chains , Models, Economic , Prosthesis Design , Quality-Adjusted Life Years , Renal Dialysis/adverse effects , Renal Dialysis/mortality , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...