Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 195
Filter
1.
BMC Vet Res ; 20(1): 222, 2024 May 24.
Article in English | MEDLINE | ID: mdl-38783269

ABSTRACT

BACKGROUND: Biomedtrix BFX® cementless total hip replacement (THR) requires the use of femoral broaches to prepare a press-fit envelope within the femur for subsequent stem insertion. Current broaches contain teeth that crush and remove cancellous bone; however, they are not particularly well-suited for broaching sclerotic (corticalized) cancellous bone. In this study, three tooth designs [Control, TG1 (additional V-grooves), TG2 (diamond tooth pattern)] were evaluated with a quasi-static testing protocol and polyurethane test blocks simulating normal and sclerotic bone. To mimic clinical broaching, a series of five sequential broach insertions were used to determine cumulative broaching energy (J) and peak loads during broach insertion. To determine the effect of broach tooth design on THR stem insertion, a BFX® stem was inserted into prepared test blocks and insertion and subsidence energy and peak loads were determined. RESULTS: Broach tooth design led to significant differences in broaching energy and peak broaching loads in test blocks of both densities. In low density test blocks, TG1 required the lowest cumulative broaching energy (10.76 ±0.29 J), followed by Control (12.18 ±1.20 J) and TG2 (16.66 ±0.78 J) broaches. In high density test blocks, TG1 required the lowest cumulative broaching energy (32.60 ±2.54 J) as compared to Control (33.25 ±2.16 J) and TG2 (59.97 ±3.07 J).  During stem insertion and subsidence testing, stem insertion energy for high density test blocks prepared with Control broaches was 14.53 ± 0.81 J, which was significantly lower than blocks prepared with TG1 (22.53 ± 1.04 J) or TG2 (19.38 ± 3.00 J) broaches. For stem subsidence testing in high density blocks, TG1 prepared blocks required the highest amount of energy to undergo subsidence (14.49 ± 0.49 J), which was significantly greater than test blocks prepared with Control (11.09 ±0.09 J) or TG2 (12.57 ± 0.81 J) broaches. CONCLUSIONS: The additional V-grooves in TG1 broaches demonstrated improved broaching performance while also generating press-fit envelopes that were more resistant to stem insertion and subsidence. TG1 broaches may prove useful in the clinical setting; however additional studies that more closely simulate clinical broach impaction are necessary prior to making widespread changes to THR broaches.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Hip/veterinary , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Animals , Dogs/surgery , Hip Prosthesis/veterinary , Biomechanical Phenomena , Femur/surgery
2.
Vet Surg ; 53(4): 620-629, 2024 May.
Article in English | MEDLINE | ID: mdl-38563528

ABSTRACT

OBJECTIVE: To describe the complications and outcomes in dogs with luxoid hip dysplasia (LH) undergoing total hip arthroplasty (THA) and compare complication rates with THA in non-LH dogs. STUDY DESIGN: Retrospective study. SAMPLE POPULATION: Client-owned dogs (n = 217) undergoing primary THA (n = 238). METHODS: Medical records (2010-2022) of dogs undergoing THA were reviewed, and LH was defined as complete dorsal displacement of the femoral head from the acetabulum on lateral projection radiographs. Major or catastrophic complications, revisions, and outcomes were recorded for all dogs and they were compared between LH and non-LH groups. RESULTS: Eighteen cases met the subcriterion for the LH group and 220 cases met the subcriterion for inclusion in the non-LH group. There were 14 complications in 13/18 dogs with LH; seven were intraoperative (femoral fissure/fracture) and seven were postoperative (dorsal luxation, n = 5; femoral fracture, n = 1; acetabular cup septic loosening, n = 1). Revisions were performed for all LH dogs that encountered complications; satisfactory outcomes were achieved in 12/13 dogs. Overall, LH dogs had a higher risk of developing complications (p < .001), including intraoperative fracture (p < .001) and postoperative dorsal luxation (p = .019) when compared with non-LH dogs. CONCLUSION: Luxoid hip dysplasia was associated with a higher risk of major complications following THA in dogs, specifically intraoperative fissure/fracture and postoperative dorsal luxation. Despite the increased risk, revisions typically yielded satisfactory outcomes. CLINICAL SIGNIFICANCE: Luxoid hip dysplasia is an important risk factor for the development of major complications in dogs undergoing THA.


Subject(s)
Arthroplasty, Replacement, Hip , Dog Diseases , Hip Dysplasia, Canine , Postoperative Complications , Dogs , Animals , Arthroplasty, Replacement, Hip/veterinary , Arthroplasty, Replacement, Hip/adverse effects , Retrospective Studies , Hip Dysplasia, Canine/surgery , Male , Postoperative Complications/veterinary , Female , Dog Diseases/surgery , Treatment Outcome
3.
Vet Radiol Ultrasound ; 65(1): 49-53, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38131525

ABSTRACT

A 2-year-old female American Akita was referred for CT of the pelvis and hindlimbs due to a left hindlimb lameness after a left total hip replacement. Referral radiographs and CT images demonstrated amorphous soft-tissue and mineral opacities surrounding the proximal femur and the prosthetic stem, consistent with the "cloud sign" reported as a characteristic of metallosis in humans. Dorsomedial displacement of the prosthetic head, multiple foci of geographic osteolysis alongside the "cloud sign", presumed pseudotumor lesions, and medial iliac lymphadenopathy were also identified with CT. Metallosis was confirmed based on ultrasound-guided cytology, revision surgery, and histopathology.


Subject(s)
Arthroplasty, Replacement, Hip , Dog Diseases , Hip Prosthesis , Animals , Dogs , Female , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/veterinary , Dog Diseases/diagnostic imaging , Dog Diseases/etiology , Dog Diseases/surgery , Femur , Hip Prosthesis/adverse effects , Hip Prosthesis/veterinary , Prosthesis Failure , Tomography, X-Ray Computed/veterinary
4.
Vet Surg ; 52(8): 1209-1218, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37752689

ABSTRACT

OBJECTIVE: To describe the surgical treatment, postoperative management, and outcome of a miniature horse undergoing total hip arthroplasty (THA). STUDY DESIGN: Case report. ANIMALS: A 4-year-old miniature horse stallion weighing 85 kg. METHODS: The horse presented with left coxofemoral luxation of ~6 weeks duration. Computed tomography confirmed craniodorsal luxation with marked degenerative changes to the femoral head. The horse underwent THA using cementless press fit implants, including an interlocking lateral bolt for the femoral stem. RESULTS: The horse recovered well from anesthesia but suffered a coma-like episode after returning to a stable. Following treatment of presumed hypovolemia, the horse regained normal mentation and was discharged 24 days after surgery. At reassessment 12 weeks postoperatively, the horse was 2/10 left hind limb lameness at trot with good healing of the surgery site. Five months postoperatively mild (1/10) lameness remained at trot but the horse was able to canter normally on both reins. The horse has since been managed normally with no veterinary treatment required for 32 months postoperatively. CONCLUSION: Total hip arthroplasty is possible in miniature horses weighing up to 85 kg and can result in a good long-term outcome.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Dislocation , Horse Diseases , Joint Dislocations , Animals , Horses , Male , Arthroplasty, Replacement, Hip/veterinary , Arthroplasty, Replacement, Hip/adverse effects , Lameness, Animal/surgery , Joint Dislocations/surgery , Joint Dislocations/veterinary , Hip Dislocation/surgery , Hip Dislocation/veterinary , Femur Head/surgery , Horse Diseases/surgery
5.
Vet Surg ; 52(8): 1219-1227, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37700514

ABSTRACT

OBJECTIVE: To report the outcome of double pelvic osteotomy (DPO) for craniodorsal luxation of total hip replacement (THR). STUDY DESIGN: Retrospective case series. ANIMALS: Eleven client-owned animals. METHODS: Dogs with craniodorsal luxation of THR and high angle of lateral opening (ALO) were considered candidates for DPO. The ALO and the version angle (VA) were measured on pre- and post-DPO radiographs. Pre- and post-DPO ALO and VA were compared using a Wilcoxon signed-rank test. Clinical and radiographic outcomes were assessed at 2 and 6 months post-DPO. RESULTS: Eleven DPOs were performed on 11 dogs after THR luxation. The ALO was reduced from a median of 66.2° (range 37.3-73.1°) to 55.9° (range 13.2-60.0°) (p ≤ .001), and VA increased from a median of 25.6° (range 6.8-51.9°) to 35.3° (range 15.1-51.7°) (p ≤ .03). Craniodorsal luxation recurred in five dogs and was managed with closed reduction (one dog), capsulorrhaphy (one dog), or repositioning of the acetabular cup (three dogs). The median clinical follow-up duration was 19.7 months (range 3.4-73.0). In the long term, seven dogs required explantation (five aseptic loosenings, two infections) (median 8.2 months, range 2.6-50.6). CONCLUSION: Reluxation was frequent after DPO, 5/11 dogs requiring additional procedures, including three cup revisions. The long-term outcome was considered to be poor due to frequent explantation. CLINICAL SIGNIFICANCE: Double pelvic osteotomy may be considered to avoid cup replacement when managing craniodorsal THR luxations in dogs but is not recommended due to high complication rates.


Subject(s)
Arthroplasty, Replacement, Hip , Dog Diseases , Hip Prosthesis , Joint Dislocations , Humans , Dogs , Animals , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/veterinary , Retrospective Studies , Hip Prosthesis/veterinary , Joint Dislocations/veterinary , Osteotomy/veterinary , Osteotomy/methods , Treatment Outcome , Dog Diseases/surgery
7.
J Am Vet Med Assoc ; 261(10): 1-7, 2023 10 01.
Article in English | MEDLINE | ID: mdl-37330224

ABSTRACT

OBJECTIVE: To evaluate the clinical outcomes associated with the Biomedtrix Centerline canine cementless total hip arthroplasty implant (C-THA). ANIMALS: 17 dogs (20 hips) surgically implanted with C-THA to treat coxofemoral pathology. CLINICAL PRESENTATION AND PROCEDURES: Dogs with C-THA (2015 through 2020) with follow-up of ≥ 6 months were evaluated. Data included signalment, complications, management of complications, radiographs (bone implant interface), and clinical outcomes. Outcomes were assessed radiographically and subjectively via surgeon orthopedic examinations. RESULTS: 15 of 20 (75%) with long term radiographic follow-up had an excellent outcome. 5 hips (25%) had postoperative complications: femoral neck fracture (n = 1; 5%), aseptic loosening (2; 10%), and septic loosening (2; 10%). CLINICAL RELEVANCE: C-THA can restore function in dogs with coxofemoral pathology. This novel procedure showed outcomes comparable to initial reports of other traditional THA implants (cemented, cementless, and hybrid) but complications occurred at a higher rate than recent outcomes of other long-standing THA procedures. Increased case numbers and surgeon experience with this novel implant system may eventually yield results comparable to other accepted THA systems.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Dogs , Animals , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/veterinary , Arthroplasty, Replacement, Hip/methods , Treatment Outcome , Hip Prosthesis/veterinary , Radiography , Retrospective Studies , Follow-Up Studies , Reoperation/veterinary
8.
Vet Comp Orthop Traumatol ; 36(4): 175-183, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36796430

ABSTRACT

OBJECTIVES: Two-dimensional measurements of acetabular geometry are widely used for the assessment of acetabular component orientation following total hip replacement (THR). With the increasing availability of computed tomography scans, there is an opportunity to develop three-dimensional (3D) planning to improve surgical accuracy. The aim of this study was to validate a 3D workflow for measuring angles of lateral opening (ALO) and version, and to establish reference values for dogs. METHODS: Pelvic computed tomography scans were obtained from 27 skeletally mature dogs with no radiographic evidence of hip joint pathology. Patient-specific 3D models were built, and ALO and version angles were measured for both acetabula. The validity of the technique was determined by calculating intra-observer coefficient of variation (CV, %). Reference ranges were calculated and data from left and right hemipelves were compared using a paired t-test and symmetry index. RESULTS: Measurements of acetabular geometry were highly repeatable (intra-observer CV 3.5-5.2%, inter-observer CV 3.3-5.2%). Mean (± standard deviation) values for ALO and version angle were 42.9 degrees (± 4.0 degrees) and 27.2 degrees (± 5.3 degrees) respectively. Left-right measurements from the same dog were symmetrical (symmetry index 6.8 to 11.1%) and not significantly different. CONCLUSIONS: Mean values of acetabular alignment were broadly similar to clinical THR guidelines (ALO of 45 degrees, version angle of 15-25 degrees), but the wide variation in angle measurements highlights the potential need for patient-specific planning to reduce the risk of complications such as luxation.


Subject(s)
Arthroplasty, Replacement, Hip , Dogs , Animals , Arthroplasty, Replacement, Hip/veterinary , Pelvis/surgery , Hip Joint/surgery , Acetabulum/diagnostic imaging , Acetabulum/surgery , Tomography, X-Ray Computed/veterinary , Tomography, X-Ray Computed/methods
9.
Vet Comp Orthop Traumatol ; 36(3): 163-168, 2023 May.
Article in English | MEDLINE | ID: mdl-36812935

ABSTRACT

OBJECTIVES: The purpose of this study was to evaluate a fluoroscopic method of angle of lateral opening (ALO) categorization based on identification of the visible portion of a pre-existing, circular recess within the metal shell of the BioMedtrix BFX acetabular component, which projects as an ellipse at clinically relevant ALO values. Our hypothesis was that there will be an association between the actual ALO and the categorization of ALO based on identification of the visible portion of the elliptical recess on a lateral fluoroscopic image at clinically relevant values. STUDY DESIGN: A custom plexiglass jig was fitted with a two-axis inclinometer and a 24 mm BFX acetabular component attached to its tabletop. Fluoroscopic reference images were obtained with the cup positioned at an ALO of 35, 45 and 55 degrees with a fixed 10 degrees of retroversion. Thirty study fluoroscopic images (10 images at each ALO) were obtained based on randomization at an ALO of 35, 45 and 55 degrees (±0.5 degrees) with 10 degrees of retroversion. The order of the study images was randomized, and a single, blinded observer categorized the 30 study images as representing an ALO of 35, 45 or 55 degrees by comparison to the reference images. RESULTS: Analysis showed perfect (30/30) agreement with a weighted kappa coefficient of 1 (95% confidence interval: -0.717 to 1). CLINICAL RELEVANCE: The results demonstrate that accurate categorization of ALO can be achieved using this fluoroscopic method. This method may prove to be a simple but effective method of estimating intraoperative ALO.


Subject(s)
Arthroplasty, Replacement, Hip , Animals , Arthroplasty, Replacement, Hip/veterinary , Arthroplasty, Replacement, Hip/methods , Reproducibility of Results , Acetabulum/diagnostic imaging , Acetabulum/surgery , Fluoroscopy/veterinary , Fluoroscopy/methods
10.
Am J Vet Res ; 84(3)2023 Mar 01.
Article in English | MEDLINE | ID: mdl-36652332

ABSTRACT

OBJECTIVE: Determine whether dogs with well-functioning orthopedic metal implants can develop metal reactivity. SAMPLE: Client-owned dogs that had tibial plateau leveling osteotomy (TPLO) or total hip replacement (THR) implants for 12 months or more and control dogs with no implants. PROCEDURES: Lymphocyte transformation testing was performed by exposing peripheral blood lymphocytes to nickel (Ni), chromium (Cr), cobalt (Co), or a combination of these metals. Lymphocyte proliferation was assessed with flow cytometry. Lymphocyte stimulation indexes (SIs) were calculated. A SI > 2 was considered reactive. Median SIs of dogs in response to metal exposure were compared statistically. RESULTS: Samples from 10 dogs with TPLO, 12 dogs with THR, and 7 control dogs were analyzed. Six dogs out of 22 with metal implants had a reactive SI to 1 or more metals, while 2 of 7 control dogs had a SI > 2 when exposed to nickel only. When all metals were considered, no differences in metal reactivity were found between TPLO, THR, and control groups. CLINICAL RELEVANCE: Metal reactivity is present in dogs and can be identified using lymphocyte transformation testing. Reactivity to Ni is present in dogs with and without metal implants. Reactivity to Co and Cr occurs in some dogs with metal implants.


Subject(s)
Anterior Cruciate Ligament Injuries , Arthroplasty, Replacement, Hip , Dog Diseases , Dogs , Animals , Arthroplasty, Replacement, Hip/veterinary , Tibia/surgery , Nickel , Prostheses and Implants , Osteotomy/veterinary , Dog Diseases/surgery , Anterior Cruciate Ligament Injuries/veterinary , Stifle/surgery , Retrospective Studies
11.
Vet Surg ; 52(1): 33-41, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36411945

ABSTRACT

OBJECTIVE: To report the outcomes and cost-benefit analysis of preclosure povidone-iodine lavage (PrePIL) used to reduce the risk of infection following total hip replacement (THR) surgery. STUDY DESIGN: Retrospective study. ANIMALS: One thousand six hundred ninety-nine dogs, 17 cats. METHODS: The medical records of 2213 consecutive THR cases were reviewed to determine the incidence of infection. The last 102 were treated with PrePIL using a commercially sourced 0.035% povidone-iodine solution. Postoperative infection rates were compared. A cost-benefit analysis was used to calculate if a PrePIL protocol is economically feasible. RESULTS: Twenty-one THRs out of 2111 (0.99%) that did not have PrePIL developed infection. Infection occurred in none of the 102 PrePIL cases. Cost analysis revealed a PrePIL break-even cost at $49.74 and a break-even infection rate of 0.949%. No complications were identified related to the use of PrePIL. CONCLUSION: Preclosure povidone-iodine lavage appeared to be efficacious in lowering THR infection rates, and it appeared to be safe for this use based on our 102 consecutive cases. The cost of the PrePIL was minimal compared to the overall cost to resolve THR infection and the potential effect on hip function prognosis. The math formulas developed can be used by surgeons to calculate cost effectiveness and break-even cost based on their THR infection rate, and to compare to the cost of a THR revision and infection resolution. CLINICAL SIGNIFICANCE: At current costs, PrePIL can be used in 2415 THR cases at a similar cost of a single revision surgery and resolution of a periprosthetic infection.


Subject(s)
Arthroplasty, Replacement, Hip , Povidone-Iodine , Animals , Dogs , Povidone-Iodine/therapeutic use , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/veterinary , Retrospective Studies , Cost-Benefit Analysis , Therapeutic Irrigation/veterinary
12.
Vet Surg ; 52(1): 168-175, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36084141

ABSTRACT

OBJECTIVE: To report the successful correction of a proximal femoral deformity (PFD) and total hip arthroplasty (THA) in a dog with the use of three-dimensionally (3D) printed custom surgical guides (CSGs). STUDY DESIGN: Case report. ANIMALS: One-year-old, male neutered, Goldendoodle. METHODS: Uniapical proximal varus and recurvatum femoral deformity (PFD) precluded femoral stem placement for THA, which was indicated for severe hip dysplasia. Using CT-derived bone and implant models, custom ostectomy and reduction guides for deformity correction were designed. A 13-hole 3.5 mm locking compression plate was contoured and applied to 3D printed models of the corrected femur and screw trajectory holes were incorporated into the CSGs. RESULTS: A caudolateral closing wedge ostectomy of the proximal femur was achieved with the aid of the CSGs and precontoured plate to within 2° of varus and 1° of recurvatum of the virtual surgical plan. Placement of a press-fit femoral stem was achieved with 7° of varus and 9° of caudal angulation. The plate was secured using six locking screws, two cortical screws, and two 18-gauge double-loop cerclage wires. No lameness and normal range of motion of the hip were observed on clinical examination 3 months after surgery. Radiographs at 3 and 6 months revealed static implant positioning, and complete bony union at the ostectomy site. CONCLUSION: Virtual surgical planning and CSGs led to successful concurrent THA and femoral deformity correction.


Subject(s)
Arthroplasty, Replacement, Hip , Male , Dogs , Animals , Arthroplasty, Replacement, Hip/veterinary , Femur/surgery , Bone Screws/veterinary , Bone Wires , Printing, Three-Dimensional
13.
Vet Surg ; 52(2): 196-208, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36062338

ABSTRACT

OBJECTIVE: To report outcomes and complications associated with total hip replacements (THR) using a multiuser canine hip registry (CHR) and owner-administered questionnaire. STUDY DESIGN: Prospective longitudinal clinical study. ANIMALS: Dogs (n = 1852). METHODS: Total hip replacement cases submitted to a CHR were reviewed. An online questionnaire including an adapted "Liverpool Osteoarthritis in Dogs" (LOAD) score was e-mailed to owners. Data were analyzed to determine associations between clinical variables and the agreement by veterinary surgeons and owners for complications. RESULTS: A group of 1329 (72%) dogs had unilateral THRs and another group of 523 (28%) dogs had bilateral THRs, resulting in 2375 THRs. Indications included hip dysplasia and osteoarthritis (n = 2028/2375, 85%). Implants were manufactured by Kyon (n = 1087, 46%), BioMedtrix CFX (n = 514, 22%), BioMedtrix hybrid (n = 264, 11%), BioMedtrix BFX (n = 221, 9%), and Helica (n = 107, 4.5%). Median veterinary surgeon and owner follow up were 1328 and 900 days respectively. Postoperative LOAD scores (21 ± 9) reported by 461 owners improved compared to preoperative scores (11 ± 9) (P < .001). Veterinary surgeons reported complications in 201/2375 (8.5%) THRs and owners in 107/461 (23%) THRs, with moderate agreement (weighted kappa = 0.44). No associations were identified between complications and weight, age, sex, or breed. BioMedtrix BFX and Helica implants were associated with increased complications (P = .031) when used for revisions of femoral head and neck excisions. CONCLUSION: Excellent outcomes, including improved canine mobility, were reported after THRs. Complications were underreported by veterinary surgeons compared to owners in this first multiuser CHR. CLINICAL SIGNIFICANCE: Canine THRs are safe, effective procedures but THR implants should be carefully selected when revising femoral head and neck excisions.


Subject(s)
Arthroplasty, Replacement, Hip , Dog Diseases , Hip Prosthesis , Osteoarthritis , Dogs , Animals , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/veterinary , Arthroplasty, Replacement, Hip/methods , Hip Prosthesis/adverse effects , Hip Prosthesis/veterinary , Prospective Studies , Dog Diseases/epidemiology , Dog Diseases/etiology , Dog Diseases/surgery , Treatment Outcome , Osteoarthritis/veterinary , Registries
14.
Vet Surg ; 52(1): 51-61, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36181274

ABSTRACT

OBJECTIVE: To evaluate the clinical outcomes of total hip replacements (THR) utilizing a BFX lateral bolt stem in dogs with coxofemoral joint disease. STUDY DESIGN: Retrospective study. SAMPLE POPULATION: A total of 149 dogs representing 195 THR. METHODS: Consecutive THRs utilizing a BFX lateral bolt stem were studied. Preoperative, immediate postoperative, 1-, 2-, 3-, 4-, and 12-month postoperative radiographs were performed. All major and minor complications, revisions, outcomes, subsidence, canal flare index (CFI) were recorded. RESULTS: An intraoperative complication rate of 11.8% was observed. The postoperative complication rate was 13.6%, with 9.2% major and 4.4% minor complications. Complications included: postoperative femur fractures (3.6%), coxofemoral luxation (3.6%), stem failure (0.5%), septic loosening (0.5%), aseptic loosening (0.5%), and acetabular fracture (0.5%). Three dogs underwent prophylactic plating after subjective assessment of cortical thickness. Five of 195 (2.6%) cases underwent explant of their prostheses (median = 3 months). Mean stem subsidence at 1 month postoperatively was 1.22 ± 0.16 mm. An increased CFI was associated with postoperative femur fractures (p < .05). A total of 190 of 195 (97.4%) cases returned to normal function in the long-term follow-up period. CONCLUSION: Use of the BFX lateral bolt stem resulted in minimal postoperative subsidence, a low femoral stem complication rate, and a high rate of achieving normal limb function. CLINICAL SIGNIFICANCE: The BFX lateral bolt stem should be considered in canine THR as the femoral failure rate is low and the long-term success rate is high.


Subject(s)
Arthroplasty, Replacement, Hip , Dog Diseases , Femoral Fractures , Hip Prosthesis , Dogs , Animals , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/veterinary , Arthroplasty, Replacement, Hip/methods , Retrospective Studies , Hip Prosthesis/veterinary , Femur/surgery , Postoperative Complications/epidemiology , Postoperative Complications/veterinary , Postoperative Complications/etiology , Femoral Fractures/surgery , Femoral Fractures/veterinary , Treatment Outcome , Reoperation/veterinary , Dog Diseases/surgery
15.
Vet Surg ; 52(1): 81-86, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36148894

ABSTRACT

OBJECTIVES: To establish preoperative and postoperative serum C reactive protein (CRP) and serum amyloid A (SAA) levels in dogs undergoing uncomplicated total hip arthroplasty (THA). STUDY DESIGN: Prospective clinical trial. ANIMALS: Eighteen client-owned dogs. METHODS: Dogs undergoing THA were recruited. Serum CRP and SAA levels were measured in all dogs the day prior to surgery, and 3 and 6 months following surgery. All dogs received a physical examination and underwent radiography at each visit, and dogs with complications were excluded from the study. For continuous numeric data, histograms were generated and evaluated for normality. A 1-way repeated measures ANOVA was performed to find differences between time points. RESULTS: No complications were encountered in any of the recruited dogs. Median age was 30 months (12-66), and the median bodyweight was 27.3 kg (22.3-40.2). Mean CRP concentrations in the preoperative, 3-month, and 6-month periods were 3.8 mg/L ± 4.4, 0.8 mg/L ± 1.9, and 1.4 mg/L ± 1.4, respectively. The mean SAA concentrations in the preoperative, 3-month, and 6-month periods were 13.9 mg/L ± 8.8, 14.1 mg/L ± 12.6, and 18.4 mg/L ± 15.1, respectively. There were no differences for each parameter between time points. CONCLUSION: C-reactive protein and SAA levels were consistent with levels previously established for noninflammatory and normal conditions in dogs. CLINICAL SIGNIFICANCE: Postoperative CRP and SAA concentrations were low by 3 months following uncomplicated THA.


Subject(s)
Acute-Phase Proteins , Arthroplasty, Replacement, Hip , Dogs , Animals , Acute-Phase Proteins/analysis , Arthroplasty, Replacement, Hip/veterinary , Prospective Studies , Serum Amyloid A Protein/metabolism , C-Reactive Protein/analysis , C-Reactive Protein/metabolism
16.
Am J Vet Res ; 83(11): 1-8, 2022 Sep 27.
Article in English | MEDLINE | ID: mdl-36136932

ABSTRACT

OBJECTIVE: To compare ex vivo postimplantation biomechanical characteristics of 3 implants for canine total hip replacement: a cementless press-fit femoral stem with a pin in the femoral neck (p-pfFS), a press-fit cementless femoral stem without this pin (pfFS), and a cemented femoral stem (cFS). SAMPLE: 18 cadaveric femurs from 9 dogs. PROCEDURES: Femurs were assigned randomly to 3 groups, and biomechanical testing was performed by measuring vertical displacement during cyclic loading and resistance to failure with compression parallel to the longitudinal axis of the femur. Force-displacement curves were assessed for failure tests, and work necessary for failure was calculated. RESULTS: No significant differences were observed in vertical displacement during cyclic loading (P = .263) or work necessary for failure (P = .079). Loads to failure for cFS and p-pfFS implants were significantly greater than that for the pfFS, but no significant difference in load to failure was observed between cFS and p-pfFS implants (P = .48). CLINICAL RELEVANCE: Cementless femoral stems with a transfixation pin offer significantly greater immediate resistance to failure to compressive loads parallel to the longitudinal axis of the femur than standard cementless stems, and a level of stability comparable to that of cemented stems. p-pfFS implants may be valuable in total hip replacement, potentially reducing the risk of fracture during the early postoperative period prior to osteointegration.


Subject(s)
Arthroplasty, Replacement, Hip , Dog Diseases , Hip Prosthesis , Dogs , Animals , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/veterinary , Hip Prosthesis/veterinary , Prosthesis Design/veterinary , Femur/surgery , Dog Diseases/surgery
17.
Vet Surg ; 51(5): 763-771, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35642440

ABSTRACT

OBJECTIVE: To report indications, complications, and long-term outcomes following feline total hip replacement (THR) using a client-based clinical metrology questionnaire, the Feline Musculoskeletal Pain Index (FMPI), and owner satisfaction. STUDY DESIGN: Multi-institutional retrospective cohort study. ANIMALS: Cats (n = 44) that underwent THR (n = 56). METHODS: Feline THRs submitted to a registry over a 10-year period were reviewed. The FMPI and owner satisfaction surveys were used to assess outcome. RESULTS: Forty-four cats met the inclusion criteria. Median age was 2 years (range: 0.9-11), and median bodyweight 5 kg (range: 3.3-7.6). British Shorthair and Domestic Shorthair were the most frequent breeds. Most cats were neutered males (33/44) and slipped capital femoral epiphysis (SCFE) was the most common surgical indication (34/56). All implants were cemented micro and nano hip implants. Overall complications (11/56) included 9 major complications. The median duration of follow up was 752 days (range: 102-3089). No association was found between clinical variables and complications. The FMPI score improved from 0.111 (range: 0-1.222) to 2.111 (range: 0.888-3.666) postoperatively (P < .001). Owner satisfaction was reported as "very good" in 30/33 cases (90.9%). CONCLUSION: A validated client metrology questionnaire showed clinical improvement in cats following THR. The most common indication for THR in cats was SCFE occurring in young male neutered cats. Complication rates were comparable to previous reports. CLINICAL SIGNIFICANCE: Total hip replacement appears to be a successful surgical treatment for feline hip disease with very good owner satisfaction and acceptable complication rates.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Animals , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/veterinary , Cats/surgery , Follow-Up Studies , Hip Prosthesis/veterinary , Humans , Male , Registries , Retrospective Studies , Treatment Outcome
20.
BMC Vet Res ; 18(1): 78, 2022 Feb 23.
Article in English | MEDLINE | ID: mdl-35197062

ABSTRACT

BACKGROUND: Total hip replacement (THR) in the gold standard surgical treatment for the canine hip. While it has been shown that greater trochanter morphology affects post-operative cementless stem position in humans, trochanter morphology and the effect on cementless stem position has not been extensively evaluated in dogs. The objective of this study was to classify greater trochanter morphology and identify potential associations between trochanter morphology and patient demographics, femoral canal geometry, surgical time, technique modifications, and post-operative stem position in client-owned dogs undergoing cementless THR. RESULTS: In this retrospective study, medical records and radiographs of 135 dogs undergoing 150 cementless total hip replacements from 2013 to 2020 were included. Trochanters were classified in the frontal plane using an ordinal grading system adapted from human THR. A Grade I trochanter denoted a trochanter positioned lateral to the periosteal surface of the lateral femoral cortex, whereas a Grade IV trochanter denoted a trochanter positioned medial to the anatomic axis of the femur. Associations between trochanter grade and other variables were examined using ANOVA, Kruskall-Wallis, or chi-squared tests. Significance was assumed at P ≤ .05. Trochanters were classified as follows: Grade I (44/150, 29.3%), Grade II (56/150, 37.4%), Grade III (44/150, 29.3%), Grade IV (6/150, 4.0%). Grade IV trochanters had lower anatomic lateral distal femoral angle (aLDFA; 91.0 ± 6.2°), angle of inclination (117.7 ± 10.5°), and canal flare index (1.53 ± 0.27). When compared to all groups, Grade IV trochanters were associated with longer surgical times (Grade IV: 227.0 ± 34.2 min; all grades: 183.2 ± 32.9 min) and technique modifications (Grade IV: 83.3%; all grades: 18%). Grade I trochanters had stems placed in valgus (- 1.8 ± 2.33°), whereas Grade II (0.52 ± 2.36°), III (0.77 ± 2.58°), and IV (0.67 ± 2.73°) trochanters exhibited varus stems. Depth of stem insertion was greater (11.2 ± 4.2 mm) for Grade IV trochanters. CONCLUSIONS: Trochanter grade was associated with post-operative stem alignment and translation in the frontal plane. Grade IV trochanters were associated with altered femoral geometry, increased surgical time, technique modifications, and stem insertion depth. Pre-operative greater trochanter classification may prove useful in identifying cases requiring prolonged surgical times or technique modifications.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Animals , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/veterinary , Demography , Dogs , Femur/diagnostic imaging , Femur/surgery , Hip Prosthesis/veterinary , Humans , Postoperative Period , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...