Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.275
Filter
2.
Catheter Cardiovasc Interv ; 103(6): 995-1003, 2024 May.
Article in English | MEDLINE | ID: mdl-38662126

ABSTRACT

BACKGROUND: Limited data exists regarding incidence, progression, and predictors of left atrial appendage (LAA) sealing after transcatheter LAA closure. We aimed to evaluate the incidence, progression, and predictive factors associated with LAA sealing after LAA closure. METHODS: This study includes patients who underwent successful LAA closure with Watchman FLX device and had both pre- and postprocedural computed tomography (CT). Postprocedural CT was performed 45 days after LAA closure and used to evaluate residual LAA patency. Patient who had residual LAA patency at 45 days underwent 1-year follow-up CT. RESULTS: A total of 105 patients (mean age: 75.2 ± 9.6 years; 53.3% female) who underwent successful LAA closure with Watchman FLX device and had pre- and postprocedural CT at 45 days were included. Residual patency was observed in 35 (33.3%) patients: 21 (20.0%) patients showed complete contrast opacification in LAA (complete LAA patency) while 14 (13.3%) patients showed contrast opacification only in the distal LAA (distal LAA patency). Among patients with residual LAA patency at 45 days, the rate of LAA sealing at 1 year was significantly higher in the distal LAA patency group than in the complete LAA patency group (75.0% vs. 16.7%; p = 0.019). Increased depth oversizing was associated with both distal LAA patency and complete LAA patency. CONCLUSION: Postprocedural CT at 45 days detected patent LAA in one-third of patients after LAA closure. LAA sealing was more frequently observed at 1 year among the distal LAA patency group than the complete LAA patency group.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cardiac Catheterization , Predictive Value of Tests , Prosthesis Design , Humans , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Female , Male , Aged , Aged, 80 and over , Risk Factors , Treatment Outcome , Time Factors , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/therapy , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Retrospective Studies , Incidence , Tomography, X-Ray Computed , Multidetector Computed Tomography
3.
Ann Noninvasive Electrocardiol ; 29(3): e13119, 2024 May.
Article in English | MEDLINE | ID: mdl-38682420

ABSTRACT

BACKGROUND: To avoid causing a thromboembolic event in patients undergoing catheter ablation for atrial fibrillation (AF), patients are treated with oral anticoagulants (OAC) prior to the procedure. Despite being on anticoagulants, some patients develop a left atrial appendage thrombus (LAAT). To exclude the presence of LAAT, transesophageal ultrasound (TEE) is performed in all patients prior to the procedure. We hypothesized continuous treatment with anticoagulants would result in a low prevalence of LAAT, in patients with low CHA2DS2-VASc score. METHOD: Medical records of consecutive patients planned to undergo AF ablation at Lund University Hospital during the years 2018-2020 were reviewed retrospectively. Examination protocols from transesophageal and transthoracic echocardiography were examined for LAAT and spontaneous echo contrast (SEC). Patients with LAAT and SEC were compared to patients without using Mann-Whitney U-test and Pearson Chi-squared analysis to test for correlation. RESULTS: Of 553 patients, three patients (0.54%) had LAAT, and 18 (3.25%) had spontaneous contrast (SEC). Patients with LAAT or SEC had a higher CHA2DS2-VASc score, more often presented in AF at TEE and less often had a normal sized left atrium. CONCLUSION: There is a low prevalence of LAAT and SEC in patients with AF scheduled for pulmonary vein isolation. Patients with SEC or LAAT tend to have paroxysmal AF less often and more often presented in AF at admission. No patients with CHA2DS2-VASc 0, paroxysmal AF, normal sized left atrium and sinus rhythm at TEE were found to have LAAT or SEC.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Catheter Ablation , Echocardiography, Transesophageal , Pulmonary Veins , Thrombosis , Humans , Echocardiography, Transesophageal/methods , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Male , Female , Pulmonary Veins/surgery , Pulmonary Veins/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnostic imaging , Catheter Ablation/methods , Retrospective Studies , Thrombosis/diagnostic imaging , Thrombosis/epidemiology , Prevalence , Middle Aged , Aged , Anticoagulants/therapeutic use , Heart Diseases/diagnostic imaging , Heart Diseases/epidemiology
4.
Int Wound J ; 21(4): e14742, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38581265

ABSTRACT

Echocardiographic guidance in left atrial appendage (LAA) closure procedures is increasingly recognized for its potential to enhance patient outcomes in atrial fibrillation (AF). This retrospective study assesses its impact on hospital stay duration, readmission rates and surgical site wound complications in 200 AF patients. Divided equally into an echocardiographically guided group (Group E) and a non-guided group (Group N), the analysis focused on detailed patient data encompassing hospital stay, 30-day readmission and wound complications. Findings revealed that Group E experienced a significantly shorter average hospital stay of 3.5 days, compared with 6.5 days in Group N, along with a lower 30-day readmission rate (5% vs. 18% in Group N). Furthermore, Group E showed a considerable reduction in surgical site wound complications, such as infections and hematomas. The study concludes that echocardiographic guidance in LAA closure procedures markedly improves postoperative wound outcomes, underscoring its potential as a standard practice in cardiac surgeries for AF patients. This approach not only optimizes patient safety and postoperative recovery but also enhances healthcare resource utilization.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Humans , Retrospective Studies , Left Atrial Appendage Closure , Treatment Outcome , Echocardiography , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Postoperative Complications/prevention & control , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery
5.
J Cardiovasc Electrophysiol ; 35(5): 1046-1049, 2024 May.
Article in English | MEDLINE | ID: mdl-38468182

ABSTRACT

INTRODUCTION: Left atrial appendage (LAA) closure (LAAC) is considered a viable alternative to anticoagulation therapy for stroke prevention in nonvalvular atrial fibrillation, we report a case with a less common shunt resulting from a device-related coronary artery-appendage fistula (CAAF) following LAAC. METHODS AND RESULTS: A 67-year-old male with a history of LAAC was referred to our emergency room with recurrent chest pain and palpitations and was diagnosed with ischemic angina pectoris. Subsequent coronary angiography (CAG) revealed 70% in-stent restenosis and an abnormal shunt of contrast originating from the left circumflex artery (LCA) to the LAA tip which did not exist before. The restenosis was successfully dilated using a drug-coated balloon, the procedure was safely completed without pericardial effusion. The patient had been implanted with a LAmbre occluder (Lifetech Scientific Corp.) in the previous LAAC procedure. This occluder had a lobe-disk design, and the distal umbrella was not fully opened after release, particularly in the lower portion. This could make the hooks embedded on the umbrella contact the LAA wall more tightly, possibly resulting in microperforation and coincidental impingement of the LCA. The epicardial adipose and hyperplastic tissue then chronically wrapped the perforated site, prevented blood outflow into the epicardium, and ultimately formed a CAAF. CONCLUSION: CAAF is a rare complication after LAAC but may be underestimated, especially for lobe-disk designed occluders. Therefore, CAG is perhaps necessary to detect this complication.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Aged , Humans , Male , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Coronary Vessels/diagnostic imaging , Left Atrial Appendage Closure , Prosthesis Design , Septal Occluder Device/adverse effects , Treatment Outcome , Vascular Fistula/diagnostic imaging , Vascular Fistula/etiology
6.
BMC Cardiovasc Disord ; 24(1): 175, 2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38515032

ABSTRACT

BACKGROUND: Approximately 90% of intracardial thrombi originate from the left atrial appendage in non-valvular atrial fibrillation patients. Even with anticoagulant therapy, left atrial appendage thrombus (LAAT) still occurs in 8% of patients. While left atrial appendage closure (LAAC) could be a promising alternative, the current consensus considers LAAT a contraindication to LAAC. However, the feasibility and safety of LAAC in patients with LAAT have yet to be determined. METHODS: This systematic review synthesizes published data to explore the feasibility and safety of LAAC for patients with LAAT. RESULTS: This study included a total of 136 patients with LAATs who underwent successful LAAC. The Amulet Amplatzer device was the most frequently utilized device (48.5%). Among these patients, 77 (56.6%) had absolute contraindications to anticoagulation therapy. Cerebral protection devices were utilized by 47 patients (34.6%). Transesophageal echocardiography (TEE) is the primary imaging technique used during the procedure. Warfarin and novel oral anticoagulants were the main anticoagulant medications used prior to the procedure, while dual antiplatelet therapy was primarily used post-procedure. During a mean follow-up period of 13.2 ± 11.5 months, there was 1 case of fatality, 1 case of stroke, 3 major bleeding events, 3 instances of device-related thrombus, and 8 cases of peri-device leakage. CONCLUSIONS: This review highlights the preliminary effectiveness and safety of the LAAC procedure in patients with persistent LAAT. Future large-scale RCTs with varied LAAT characteristics and LAAC device types are essential for evidence-based decision-making in clinical practice.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Thrombosis , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Left Atrial Appendage Closure , Atrial Appendage/diagnostic imaging , Anticoagulants/adverse effects , Stroke/etiology , Stroke/prevention & control , Stroke/drug therapy , Thrombosis/diagnostic imaging , Thrombosis/etiology , Thrombosis/prevention & control , Treatment Outcome
8.
J Cardiovasc Med (Hagerstown) ; 25(5): 345-352, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38477853

ABSTRACT

Ischemic stroke prevention represents a crucial concern in health systems, being associated with high morbidity and mortality. Atrial fibrillation is associated with 15-20% of ischemic strokes, in the presence of thrombus in the left atrial appendage in 90% of patients with nonvalvular atrial fibrillation. Oral anticoagulation represents the standard of care. However, left atrial appendage occlusions have been developed for selected patients with nonvalvular atrial fibrillation. With regard to the latter, particularly, some important concerns have been raised on the selection of patients potentially amenable to the procedure, seemingly emphasizing a gap in knowledge, real-life clinical practice, and current management guidelines. In light of the recent evidence regarding the current indications for management of left atrial appendage in presence of nonvalvular atrial fibrillation, the purpose of this critical review is to highlight the blind spots of left atrial appendage occlusion indications, taking into account the evidence-based mid- to long-term outcomes. Apparently, many unsolved concerns and problems are still present, mainly including mid- and long-term device-related potential complications, the possibility of concurrent sources of embolization, ethical and economic issues. Furthermore, larger, well designed, long-term, multicentric, and more inclusive studies, as well as shared/integrated registries are needed, aiming at comparing direct oral anticoagulation with left atrial appendage occlusion in the long run.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Stroke/etiology , Stroke/prevention & control , Atrial Appendage/diagnostic imaging , Anticoagulants/therapeutic use , Treatment Outcome
12.
Int J Cardiol ; 405: 131939, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38458388

ABSTRACT

BACKGROUND: Advances in imaging have led to procedural optimization of left atrial appendage closure (LAAC). Contrast-free approaches, guided merely by echocardiography, have been established, however data on this topic remains scarce. In this analysis, we assessed contrast-free procedural results with the LAMBRE LAAC device. METHODS: The multicenter retrospective BoBoMa (Bonn/Bordeaux/Mainz)-Registry included a total of 118 patients that underwent LAAC with LAMBRE devices omitting contrast-dye. Baseline and echocardiographic characteristics as well as intra- and postprocedural complications and outcomes were assessed. RESULTS: Patients were at a mean age of 77.5 ± 7.5 years with high thromboembolic and bleeding risk (CHADS-VASc-score 4.6 ± 1.4, HAS-BLED-score 3.7 ± 1.0, respectively). Renal function was impaired with a mean glomerular filtration rate (GFR) of 50 ± 22 ml/min. Mean procedural time was 47.2 ± 37.5  minutes with a mean radiation dose of 4.75 ± 5.25 Gy*cm2. Device success, defined as proper deployment in a correct position, was achieved in 97.5% (115/118) of cases with repositioning of the occluder in 7.6% (9/118) and resizing in 3.4% (4/118) of cases. No relevant peri-device leakage (>3 mm) was observed with 42% of occluders being implanted in an ostial position. Periprocedural complications occurred in 6.8% (8/118) of cases, including two cases of device embolization and one case of clinically-relevant pericardial effusion requiring surgical intervention. Other complications included pericardial effusion (2.5%, 3/118) and vascular access site complications (1.7%, 2/118). CONCLUSION: Echocardiography-guided contrast-free LAAC using the LAMBRE device is safe and feasible. Further prospective studies including the direct comparison of devices as well as imaging techniques are warranted in contrast-free LAAC.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Septal Occluder Device , Humans , Atrial Appendage/surgery , Atrial Appendage/diagnostic imaging , Male , Female , Aged , Retrospective Studies , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnostic imaging , Aged, 80 and over , Registries , Treatment Outcome , Echocardiography, Transesophageal/methods , Contrast Media/administration & dosage , Follow-Up Studies
13.
Sci Rep ; 14(1): 5860, 2024 03 11.
Article in English | MEDLINE | ID: mdl-38467726

ABSTRACT

Atrial fibrillation (AF) is the most common human arrhythmia, forming thrombi mostly in the left atrial appendage (LAA). However, the relation between LAA morphology, blood patterns and clot formation is not yet fully understood. Furthermore, the impact of anatomical structures like the pulmonary veins (PVs) have not been thoroughly studied due to data acquisition difficulties. In-silico studies with flow simulations provide a detailed analysis of blood flow patterns under different boundary conditions, but a limited number of cases have been reported in the literature. To address these gaps, we investigated the influence of PVs on LA blood flow patterns and thrombus formation risk through computational fluid dynamics simulations conducted on a sizeable cohort of 130 patients, establishing the largest cohort of patient-specific LA fluid simulations reported to date. The investigation encompassed an in-depth analysis of several parameters, including pulmonary vein orientation (e.g., angles) and configuration (e.g., number), LAA and LA volumes as well as their ratio, flow, and mass-less particles. Our findings highlight the total number of particles within the LAA as a key parameter for distinguishing between the thrombus and non-thrombus groups. Moreover, the angles between the different PVs play an important role to determine the flow going inside the LAA and consequently the risk of thrombus formation. The alignment between the LAA and the main direction of the left superior pulmonary vein, or the position of the right pulmonary vein when it exhibits greater inclination, had an impact to distinguish the control group vs. the thrombus group. These insights shed light on the intricate relationship between PV configuration, LAA morphology, and thrombus formation, underscoring the importance of comprehensive blood flow pattern analyses.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Pulmonary Veins , Thrombosis , Humans , Atrial Appendage/diagnostic imaging , Pulmonary Veins/diagnostic imaging , Echocardiography, Transesophageal , Heart Atria/diagnostic imaging , Atrial Fibrillation/diagnostic imaging
14.
EuroIntervention ; 20(5): e301-e311, 2024 Mar 04.
Article in English | MEDLINE | ID: mdl-38436367

ABSTRACT

BACKGROUND: The optimal antithrombotic therapy following left atrial appendage occlusion (LAAO) remains debated. Ideally, this therapy should effectively prevent device-related thrombosis (DRT) while minimising the associated bleeding risk. AIMS: We aimed to evaluate the long-term safety and efficacy of a postprocedural single antiplatelet therapy (SAPT) strategy following Amplatzer LAAO in a large consecutive cohort. METHODS: This retrospective, single-centre, observational study included all patients discharged on SAPT after LAAO with the Amplatzer Cardiac Plug (ACP) or Amplatzer Amulet between March 2010 and December 2021 at Aarhus University Hospital, Denmark. Baseline, procedural, and imaging data were obtained locally, while clinical outcomes and medication data were extracted from the Danish national health registries. RESULTS: A total of 553 patients underwent Amplatzer LAAO during the specified time frame. Of these, 431 (77.9%) high bleeding risk patients were discharged on SAPT with either acetylsalicylic acid (n=403, 72.9%) or clopidogrel (n=28, 5.1%). At 6 months, 173 (41.7%) patients were not on any antithrombotic therapy. The mean CHA2DS2-VASc and HAS-BLED scores were 3.9±1.5 and 3.4±1.1, respectively. DRT was detected in 6 (1.5%) patients on 8-week follow-up imaging using cardiac computed tomography (n=386, 89.6%) or transoesophageal echocardiography (n=27, 6.3%). The 1-year ischaemic stroke rate was 2.2% (95% confidence interval [CI]: 1.1-4.2). One-year rates for major bleeding and cardiovascular death were 5.9% (95% CI: 4.0-8.9) and 2.9% (95% CI: 1.6-5.1), respectively. CONCLUSIONS: SAPT following Amplatzer LAAO displayed rates of DRT and stroke comparable to those reported with more intensive antithrombotic regimens. Meanwhile, we observed low rates of major bleeding.


Subject(s)
Atrial Appendage , Brain Ischemia , Stroke , Humans , Platelet Aggregation Inhibitors/therapeutic use , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Fibrinolytic Agents , Retrospective Studies , Stroke/etiology , Stroke/prevention & control , Hemorrhage/chemically induced
18.
J Am Heart Assoc ; 13(5): e032200, 2024 Mar 05.
Article in English | MEDLINE | ID: mdl-38390794

ABSTRACT

BACKGROUND: In patients with acute cardiogenic cerebral embolism, a residual thrombus may still be present in the cardiac cavity even after reperfusion therapy. We aimed to investigate the occurrence of a residual cardiac thrombus in cardioembolic stroke after reperfusion therapy and analyze its impact on clinical outcome. METHODS AND RESULTS: We enrolled patients with cardioembolic stroke from our prospectively collected database who underwent 2-phase cardiac computed tomography within 7 days after reperfusion therapy. Residual cardiac thrombus was defined as a filling defect on both early- and late-phase images, whereas circulatory stasis was defined as a filling defect only on the early-phase images in the left atrial appendage. The primary outcome was a poor clinical outcome (modified Rankin Scale score, 3-6) at 90 days. The secondary outcome was a composite end point event (cardiovascular death, nonfatal myocardial infarction, nonfatal stroke) at 90 days. A total of 303 patients were included, of whom 94 (31.0%) had a residual cardiac thrombus. Binary logistic regression analysis showed that the presence of a residual cardiac thrombus was associated with a poor clinical outcome (odds ratio, 1.951 [95% CI, 1.027-3.707]; P=0.041) but not circulatory stasis in the left atrial appendage (odds ratio, 1.096 [95% CI, 0.542-2.217]; P=0.798). Furthermore, there was no correlation between a residual cardiac thrombus and the composite end point event (30.0% versus 31.1%; P=1.000). CONCLUSIONS: Residual cardiac thrombus occurs in approximately one-third of patients with cardioembolic stroke after reperfusion therapy and is often indicative of a poor clinical outcome.


Subject(s)
Atrial Appendage , Embolic Stroke , Stroke , Thrombosis , Humans , Stroke/etiology , Stroke/epidemiology , Atrial Appendage/diagnostic imaging , Thrombosis/diagnostic imaging , Thrombosis/etiology , Reperfusion
19.
J Cardiovasc Med (Hagerstown) ; 25(4): 280-293, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38407860

ABSTRACT

BACKGROUND: New nonclinical parameters are needed to improve the current stroke risk stratification schemes for patients with atrial fibrillation. This study aimed to summarize data on potential cardiac imaging correlates and predictors of stroke or systemic embolism in patients with atrial fibrillation. METHODS: MEDLINE, EMBASE, and Web of Science were searched to identify all published studies providing relevant data through 16 November 2022. Random effects meta-analysis method was used to pool estimates. RESULTS: We included 64 studies reporting data from a pooled population of 56 639 patients. Left atrial spontaneous echo-contrast [adjusted odds ratio (aOR) 3.32, 95% confidence interval (CI) 1.98-5.49], nonchicken wing left atrial appendage (LAA) morphology (aOR 2.15, 95% CI 1.11-4.18), left atrial enlargement (aOR 2.12, 95% CI 1.45-3.08), and higher LAA orifice diameter (aOR 1.56, 95% CI 1.18-2.05) were highly associated with stroke. Other parameters associated with stroke included higher left atrial sphericity (aOR 1.14, 95% CI 1.01-1.29), higher left atrial volume (aOR 1.03, 95% CI 1.01-1.04), higher left atrial volume index (aOR 1.014, 95% CI 1.004-1.023), lower left atrial reservoir strain [adjusted hazard ratio (aHR) 0.86, 95% CI 0.76-0.98], higher left ventricular mass index (aOR 1.010, 95% CI 1.005-1.015) and E / e' ratio (aOR 1.12, 95% CI 1.07-1.16). There was no association between LAA volume (aOR 1.37, 95% CI 0.85-2.21) and stroke. CONCLUSION: These cardiac imaging parameters identified as potential predictors of thromboembolism may improve the accuracy of stroke risk stratification schemes in patients with atrial fibrillation. Further studies should evaluate the performance of holistic risk scores including clinical factors, biomarkers, and cardiac imaging.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Thromboembolism , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/diagnostic imaging , Stroke/diagnostic imaging , Stroke/etiology , Risk Factors , Cardiac Imaging Techniques , Atrial Appendage/diagnostic imaging , Echocardiography, Transesophageal
20.
BMC Cardiovasc Disord ; 24(1): 130, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38424513

ABSTRACT

INTRODUCTION: We described a rare case of an adolescent girl with paroxysmal atrial fibrillation originating from the right atrial appendage diverticulum and successfully converted to sinus rhythm after surgical intervention. METHODS: A 19-year-old girl was referred to the hospital for a catheter ablation of paroxysmal atrial fibrillation. conventional radiofrequency ablation using 3-D mapping were ineffective. Activation mapping showed the root of the free wall atrial appendage was first excited and catheter modeling (3D Carto map) showed a sac-like structure. RESULTS: We did selective angiography and further Computed tomography angiography (CTA) and Transesophageal echocardiography (TEE) which showed diverticulum originating from the right atrial appendage. Hence the patient was referred to cardiac surgery and had no recurrent atrial fibrillation at three months postoperative follow up. CONCLUSIONS: Right atrial appendage diverticulum was an extremely rare malformation that can coexist with atrial tachyarrhythmia. Surgical ligation or excision of the abnormal structure with local ablation can achieve excellent results.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Catheter Ablation , Female , Humans , Young Adult , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/diagnostic imaging , Catheter Ablation/methods , Echocardiography, Transesophageal/methods , Heart Atria , Tachycardia , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...