Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 53
Filter
1.
BMC Cardiovasc Disord ; 24(1): 367, 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39014301

ABSTRACT

OBJECTIVE: To investigate the accuracy and consistency of MDCT and TEE in the preoperative assessment of aortic root surgery. METHODS: From January 2021 to September 2022, 118 patients who underwent aortic root surgery were included in this study. All patients underwent high-quality preoperative MDCT and TEE examinations, and the examination results were independently measured and assessed by two senior radiologists or ultrasound specialists. Bland-Altman analysis and Pearson correlation testing were employed to assess the correlation and consistency between MDCT and TEE. These analyses were then compared with actual intraoperative measurement data. RESULTS: Among all the patients, 73 (61.86%) had tricuspid aortic valve (TAV), and 45 (38.14%) had bicuspid aortic valve (BAV). A comparison between the TEE and MDCT measurements showed that for the annulus diameter, the area-derived diameter had the best correlation and agreement. For the sinus of Valsalva diameter, the circumference-derived diameter was optimal. However, for the STJ diameter, the minimum cross-sectional diameter showed the best agreement with TEE. In contrast, measurements of geometric height showed a weaker correlation and agreement. CONCLUSION: Contrast-enhanced MDCT can be a valuable tool for perioperative evaluation in aortic root surgery, with good correlation, consistency, and feasibility when compared to TEE. The choice of MDCT measurement methodology, specifically area-derived and circumference-derived diameter, proved to be more accurate than other methods. Further research is required to enhance the understanding of aortic valve repair and associated imaging techniques.


Subject(s)
Aortic Valve , Bicuspid Aortic Valve Disease , Echocardiography, Transesophageal , Multidetector Computed Tomography , Predictive Value of Tests , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/abnormalities , Male , Female , Middle Aged , Aged , Reproducibility of Results , Bicuspid Aortic Valve Disease/surgery , Bicuspid Aortic Valve Disease/diagnostic imaging , Adult , Retrospective Studies , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/surgery , Preoperative Care
2.
Circulation ; 149(25): 1938-1948, 2024 06 18.
Article in English | MEDLINE | ID: mdl-38804148

ABSTRACT

BACKGROUND: Ascending aorta dilation and aortic valve degeneration are common complications in patients with bicuspid aortic valve. Several retrospective studies have suggested the benefit of statins in reducing these complications. This study aimed to determine whether atorvastatin treatment is effective in reducing the growth of aortic diameters in bicuspid aortic valve and if it slows the progression of valve calcification. METHODS: In a randomized clinical trial, 220 patients with bicuspid aortic valve (43 women; 46±13 years of age) were included and treated with either 20 mg of atorvastatin per day or placebo for 3 years. Inclusion criteria were ≥18 years of age, nonsevere valvular dysfunction, nonsevere valve calcification, and ascending aorta diameter ≤50 mm. Computed tomography and echocardiography studies were performed at baseline and after 3 years of treatment. RESULTS: During follow-up, 28 patients (12.7%) discontinued medical treatment (15 on atorvastatin and 13 taking placebo). Thus, 192 patients completed the 36 months of treatment. Low-density lipoprotein cholesterol levels decreased significantly in the atorvastatin group (median [interquartile range], -30 mg/dL [-51.65 to -1.75 mg/dL] versus 6 mg/dL [-4, 22.5 mg/dL]; P<0.001). The maximum ascending aorta diameter increased with no differences between groups: 0.65 mm (95% CI, 0.45-0.85) in the atorvastatin group and 0.74 mm (95% CI, 0.45-1.04) in the placebo group (P=0.613). Similarly, no significant differences were found for the progression of the aortic valve calcium score (P=0.167) or valvular dysfunction. CONCLUSIONS: Among patients with bicuspid aortic valve without severe valvular dysfunction, atorvastatin treatment was not effective in reducing the progression of ascending aorta dilation and aortic valve calcification during 3 years of treatment despite a significant reduction in low-density lipoprotein cholesterol levels. REGISTRATION: URL: https://www.clinicaltrialsregister.eu; Unique identifier: 2015-001808-57. URL: https://www.clinicaltrials.gov; Unique identifier: NCT02679261.


Subject(s)
Aortic Valve , Atorvastatin , Bicuspid Aortic Valve Disease , Calcinosis , Disease Progression , Heart Valve Diseases , Hydroxymethylglutaryl-CoA Reductase Inhibitors , Humans , Atorvastatin/therapeutic use , Female , Male , Middle Aged , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Aortic Valve/abnormalities , Aortic Valve/drug effects , Calcinosis/drug therapy , Calcinosis/diagnostic imaging , Calcinosis/pathology , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/drug therapy , Heart Valve Diseases/drug therapy , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/pathology , Adult , Hydroxymethylglutaryl-CoA Reductase Inhibitors/therapeutic use , Dilatation, Pathologic/drug therapy , Follow-Up Studies , Double-Blind Method , Treatment Outcome , Aorta/diagnostic imaging , Aorta/pathology , Aorta/drug effects , Aortic Valve Disease/drug therapy , Aortic Valve Stenosis
3.
Ann Biomed Eng ; 52(8): 2258-2268, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38734846

ABSTRACT

Patients with bicuspid aortic valve (BAV) commonly have associated aortic stenosis and aortopathy. The geometry of the aortic arch and BAV is not well defined quantitatively, which makes clinical classifications subjective or reliant on limited 2D measurements. The goal of this study was to characterize the 3D geometry of the aortic arch and BAV using objective and quantitative techniques. Pre-TAVR computed tomography angiogram (CTA) in patients with BAV and aortic stenosis (AS) were analyzed (n = 59) by assessing valve commissural angle, presence of a fused region, percent of fusion, and calcium volume. The ascending aorta and aortic arch were reconstructed from patient-specific imaging segmentation to generate a centerline and calculate maximum curvature and maximum area change for the ascending aorta and the descending aorta. Aortic valve commissural angle signified a bimodal distribution suggesting tricuspid-like (≤ 150°, 52.5% of patients) and bicuspid-like (> 150°, 47.5%) morphologies. Tricuspid like was further classified by partial (10.2%) or full (42.4%) fusion, and bicuspid like was further classified into valves with fused region (27.1%) or no fused region (20.3%). Qualitatively, the aortic arch was found to have complex patient-specific variations in its 3D shape with some showing extreme diameter changes and kinks. Quantitatively, subgroups were established using maximum curvature threshold of 0.04 and maximum area change of 30% independently for the ascending and descending aorta. These findings provide insight into the geometric structure of the aortic valve and aortic arch in patients presenting with BAV and AS where 3D characterization allows for quantitative classification of these complex anatomic structures.


Subject(s)
Aorta, Thoracic , Aortic Valve , Bicuspid Aortic Valve Disease , Imaging, Three-Dimensional , Humans , Bicuspid Aortic Valve Disease/diagnostic imaging , Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Aorta, Thoracic/diagnostic imaging , Male , Female , Aged , Heart Valve Diseases/diagnostic imaging , Middle Aged , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aged, 80 and over , Computed Tomography Angiography
5.
Catheter Cardiovasc Interv ; 104(1): 105-114, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38819623

ABSTRACT

BACKGROUND: The anatomic substrate of bicuspid valves may lead to suboptimal TAVR stent expansion and geometry. AIM: We evaluated determinants of stent geometry in bicuspid valves treated with Sapien transcatheter aortic valve replacement (TAVR) valves. METHODS: A multicenter retrospective registry of patients (February 2019 to August 2022) who underwent post-TAVR computed tomography to determine stent area (vs. nominal valve area) and stent ellipticity (maximum diameter/minimum diameter). Predictors of relative stent expansion (minimum area/average of inflow + outflow area) and stent ellipticity were evaluated in a multivariable regression model, including valve calcium volume (indexed by annular area), presence of raphe calcium, sinus diameters indexed by area-derived annular diameter, and performance of pre-dilation and post-dilation. RESULTS: The registry enrolled 101 patients from four centers. The minimum stent area (vs. nominal area) was 88.1%, and the maximum ellipticity was 1.10, with both observed near the midframe of the valve in all cases. Relative stent expansion ≥90% was observed in 64/101 patients. The only significant predictor of relative stent expansion ≥90% was the performance of post-dilation (OR: 4.79, p = 0.018). Relative stent expansion ≥90% was seen in 86% of patients with post-dilation compared to 57% without (p < 0.001). The stent ellipticity ≥1.1 was observed in 47/101 patients. The significant predictors of stent ellipticity ≥1.1 were the indexed maximum sinus diameter (OR: 0.582, p = 0.021) and indexed intercommisural diameter at 4 mm (OR: 2.42, p = 0.001). Stent expansion has a weak negative correlation with post-TAVR mean gradient (r = -0.324, p < 0.001). CONCLUSION: Relative stent expansion ≥90% was associated with the performance of post-dilation, and stent ellipticity ≥1.1 was associated with indexed intercommisural diameter and indexed maximum sinus diameter. Further studies to determine optimal deployment strategies in bicuspid valves are needed.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Female , Male , Retrospective Studies , Aged, 80 and over , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/physiopathology , Aged , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/surgery , Balloon Valvuloplasty/adverse effects , Risk Factors , United States , Stents
6.
Am J Physiol Heart Circ Physiol ; 327(1): H56-H66, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38758128

ABSTRACT

Mouse models of congenital aortic valve malformations are useful for studying disease pathobiology, but most models have incomplete penetrance [e.g., ∼2 to 77% prevalence of bicuspid aortic valves (BAVs) across multiple models]. For longitudinal studies of pathologies associated with BAVs and other congenital valve malformations, which manifest over months in mice, it is operationally inefficient, economically burdensome, and ethically challenging to enroll large numbers of mice in studies without first identifying those with valvular abnormalities. To address this need, we established and validated a novel in vivo high-frequency (30 MHz) ultrasound imaging protocol capable of detecting aortic valvular malformations in juvenile mice. Fifty natriuretic peptide receptor 2 heterozygous mice on a low-density lipoprotein receptor-deficient background (Npr2+/-;Ldlr-/-; 32 males and 18 females) were imaged at 4 and 8 wk of age. Fourteen percent of the Npr2+/-;Ldlr-/- mice exhibited features associated with aortic valve malformations, including 1) abnormal transaortic flow patterns on color Doppler (recirculation and regurgitation), 2) peak systolic flow velocities distal to the aortic valves reaching or surpassing ∼1,250 mm/s by pulsed-wave Doppler, and 3) putative fusion of cusps along commissures and abnormal movement elucidated by two-dimensional (2-D) imaging with ultrahigh temporal resolution. Valves with these features were confirmed by ex vivo gross anatomy and histological visualization to have thickened cusps, partial fusions, or Sievers type-0 bicuspid valves. This ultrasound imaging protocol will enable efficient, cost effective, and humane implementation of studies of congenital aortic valvular abnormalities and associated pathologies in a wide range of mouse models.NEW & NOTEWORTHY We developed a high-frequency ultrasound imaging protocol for diagnosing congenital aortic valve structural abnormalities in 4-wk-old mice. Our protocol defines specific criteria to distinguish mice with abnormal aortic valves from those with normal tricuspid valves using color Doppler, pulsed-wave Doppler, and two-dimensional (2-D) imaging with ultrahigh temporal resolution. This approach enables early identification of valvular abnormalities for efficient and ethical experimental design of longitudinal studies of congenital valve diseases and associated pathologies in mice.


Subject(s)
Aortic Valve , Disease Models, Animal , Receptors, Atrial Natriuretic Factor , Animals , Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Female , Male , Receptors, Atrial Natriuretic Factor/genetics , Receptors, Atrial Natriuretic Factor/deficiency , Receptors, Atrial Natriuretic Factor/metabolism , Mice , Mice, Knockout , Receptors, LDL/genetics , Receptors, LDL/deficiency , Mice, Inbred C57BL , Bicuspid Aortic Valve Disease/diagnostic imaging
7.
Int J Cardiol ; 409: 132201, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38782071

ABSTRACT

BACKGROUND: To date, whether ascending aorta dilation (AAD) should be considered a contraindication for transcatheter aortic valve replacement (TAVR) remains a topic of debate.. OBJECTIVE: The study investigated the clinical outcome of TAVR in patients with bicuspid aortic valve stenosis (BAV-AS) complicated by AAD. METHODS: We included patients with BAV-AS who underwent TAVR between 2012 and 2019. We collected patient perioperative clinical data., tracked clinical outcomes for over four years post-TAVR, and obtained echocardiography images one year postoperatively. The Kaplan-Meier method was employed for analyzing both unadjusted and adjusted survival data, which was compared using the log-rank test. COX regression and nomograms were used to assess the impact of AAD on post-TAVR clinical outcomes in patients with aortic stenosis (AS), with all-cause mortality as the primary clinical endpoint. RESULTS: A total of 111 BAV patients were included in this study. Long-term follow-up showed an increased mortality risk in patients with BAV-AAD (adjusted Kaplan-Meier analysis: P = .02/0.001). Cox correlation analysis indicated that age (OR = 1.137; P = .034), AAD (OR = 3.51; P = .038), and postoperative left ventricular pressure (LVSP) (OR: 0.959; P = .044) were predictive factors for mortality more than four years after TAVR in patients with BAV. The area under the curve of the Nomogram predicting long-term survival for the training set of patients based on the above metrics was 0.845 (95% CI: 0.696-0.994). Short-term cardiac ultrasound follow-up showed a more rapid rate of AA expansion (0.29 [0-0.34] vs. -1 [-3.3-1] mm/month, P = .001) and a smaller proportion of AA diameter reduction (7.1% vs. 53.7%, P = .001) in patients who died. CONCLUSIONS: Patients with BAV-AAD-AS treated with TAVR have an increased risk of long-term mortality, and clinical prediction models, including AAD age and postoperative LVSP, may predict long-term patient survival. CONDENSED ABSTRACT: The study investigated the clinical outcome of transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (BAV-AS) complicated by ascending aorta dilation (AAD). Patients with BAV-AAD-AS treated with TAVR have an increased risk of long-term mortality. AAD, age and postoperative LVSP, may predict long-term patient survival. Short-term cardiac ultrasound follow-up showed a more rapid rate of AA expansion and a smaller proportion of AA diameter reduction in patients who died. A high postoperative AAD expansion rate may indicate an adverse clinical outcome. Surgery regimens for tolerable BAV-AADs and can be considered as a treatment option.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aged , Bicuspid Aortic Valve Disease/surgery , Bicuspid Aortic Valve Disease/complications , Bicuspid Aortic Valve Disease/diagnostic imaging , Treatment Outcome , Follow-Up Studies , Retrospective Studies , Aged, 80 and over , Time Factors , Middle Aged
8.
JACC Cardiovasc Interv ; 17(14): 1652-1663, 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-38749449

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: The aim of this study was to identify the incidence, predictors, and clinical outcomes of PVR after TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with Sievers type 1 BAV stenosis undergoing TAVR with current-generation transcatheter heart valves (THVs) in 24 international centers were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAEs), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%)-mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were a larger virtual raphe ring perimeter (adjusted OR: 1.07; 95% CI: 1.02-1.13), severe annular or left ventricular outflow tract calcification (adjusted OR: 5.21; 95% CI: 1.45-18.77), a self-expanding valve (adjusted OR: 9.01; 95% CI: 2.09-38.86), and intentional supra-annular THV positioning (adjusted OR: 3.31; 95% CI: 1.04-10.54). At a median follow-up of 1.3 years (Q1-Q3: 0.5-2.4 years), moderate or severe PVR was associated with an increased risk of MAEs (adjusted HR: 2.52; 95% CI: 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAEs during follow-up.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Aortic Valve , Bicuspid Aortic Valve Disease , Heart Valve Prosthesis , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Risk Factors , Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/abnormalities , Treatment Outcome , Aged, 80 and over , Incidence , Time Factors , Bicuspid Aortic Valve Disease/surgery , Bicuspid Aortic Valve Disease/diagnostic imaging , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/surgery , Heart Valve Diseases/physiopathology , Europe , Risk Assessment , Prosthesis Design , Odds Ratio , Stroke/etiology , Stroke/diagnosis , Heart Failure/physiopathology , Heart Failure/etiology , Heart Failure/diagnosis , Retrospective Studies
10.
Int J Cardiol ; 407: 132000, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38561108

ABSTRACT

AIM: To evaluate the association between raphe in bicuspid aortic valve (BAV) patients and valve dysfunction, aortopathy and aortic valve surgery in the REBECCA registry [REgistro della valvola aortica Bicuspide della Società Italiana di ECocardiografia e CArdiovascular Imaging (SIECVI)]. METHODS: Prevalence of aortic valve dysfunction and aortopathy was investigated in BAV patients with and without raphe. Aortic valve dysfunction (regurgitation or stenosis) was categorized as mild, moderate and severe. Aortopathy was defined as annulus ≥14 mm/m2; root ≥20 mm/m2; sinotubular junction ≥16 mm/m2; ascending aorta ≥17 mm/m2, and classified in Type A, isolated ascending aorta dilatation; Type B, aortic root and ascending aorta dilatation; and Type C, isolated aortic root dilatation. RESULTS: Overall, 695 patients with BAV were enrolled; 520 (74.8%) with raphe and 175 (25.2%) without raphe. BAV patients with raphe presented more frequently with moderate or severe aortic stenosis than BAV patients without raphe (183 [35.2%] vs 34 [19.4%], p < 0.001). A higher prevalence of aortopathy, particularly Type B, was observed in patients with vs without raphe. At multivariable analysis, raphe was a predictor of aortic valve surgery at three-year follow-up (odds ratio 2.19, 95% confidence interval 1.08-4.44, p < 0.001). CONCLUSIONS: Patients with BAV and raphe have a higher prevalence of significant aortic stenosis, aortopathy, especially Type B, and a higher risk of undergoing aortic valve surgery at three-year follow-up.


Subject(s)
Aortic Valve , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Registries , Humans , Male , Female , Bicuspid Aortic Valve Disease/surgery , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/complications , Middle Aged , Aortic Valve/abnormalities , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aged , Heart Valve Diseases/surgery , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/complications , Aortic Diseases/surgery , Aortic Diseases/diagnostic imaging , Aortic Diseases/epidemiology , Adult , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Follow-Up Studies , Italy/epidemiology
11.
Catheter Cardiovasc Interv ; 103(6): 1004-1014, 2024 May.
Article in English | MEDLINE | ID: mdl-38577939

ABSTRACT

INTRODUCTION: Bicuspid aortic valve (BAV) stenosis is a complex anatomical scenario for transcatheter aortic valve implantation (TAVI). Favorable short-term clinical outcomes have been reported with TAVI in this setting, but long-term data are scarce. METHODS: We retrospectively included, in a single-center registry, patients with BAV stenosis who underwent TAVI before 2020. We compared patients treated with self-expanding valves (SEV) versus balloon-expandable valves (BEV). The primary endpoint was a composite of all-cause mortality, stroke and need for aortic valve (AV) reintervention at 3 years. Secondary endpoints included each component of the primary endpoint, cardiovascular mortality, permanent pacemaker implantation (PPI) rate, mean gradient and ≥moderate paravalvular leak (PVL) rate. RESULTS: A total of 150 consecutive patients (SEV = 83, BEV = 67) were included. No significant differences were reported between SEV and BEV groups for the primary composite endpoint (SEV 35.9% vs. BEV 32%, p = 0.66), neither for clinical secondary endpoints (all-cause mortality SEV 28.1% vs. BEV 28%, p = 0.988; cardiovascular mortality SEV 14.1% vs. BEV 20%, p = 0.399; stroke SEV 12.5% vs. BEV 6%, p = 0.342; need for AV reintervention SEV 0% vs. BEV 0%; PPI SEV 28.1% vs. BEV 24%, p = 0.620). A lower mean gradient persisted up to 3 years in the SEV group (SEV 8.8 ± 3.8 mmHg vs. BEV 10.7 ± 3.2 mmHg, p = 0.063), while no significant difference was found in the rate of ≥ moderate PVL (SEV 3/30 vs. BEV 0/25, p = 0.242). CONCLUSIONS: In this single center registry, we observed favorable 3-year clinical outcomes in nonselected BAV patients treated with different generation devices, without significant differences between patients receiving SEV or BEV.


Subject(s)
Aortic Valve Stenosis , Balloon Valvuloplasty , Bicuspid Aortic Valve Disease , Heart Valve Prosthesis , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Male , Female , Retrospective Studies , Treatment Outcome , Bicuspid Aortic Valve Disease/physiopathology , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/mortality , Bicuspid Aortic Valve Disease/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Time Factors , Aged , Balloon Valvuloplasty/adverse effects , Balloon Valvuloplasty/mortality , Aged, 80 and over , Risk Factors , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/abnormalities , Recovery of Function , Hemodynamics , Risk Assessment
14.
J Cardiovasc Electrophysiol ; 35(6): 1069-1077, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38509335

ABSTRACT

INTRODUCTION: Bicuspid aortic valves (BAV) are the most common congenital heart defects and the extent of ventricular arrhythmias (VA) in patients with BAV is unclear. The objective of this study is to describe VAs and late gadolinium enhancement cardiac magnetic resonance imaging (LGE-CMR) in patients with BAV. METHODS: A total of 19 patients with BAV (18 males, age: 58 ± 13 years) were referred for VA ablation procedures. Ten patients had BAVs at the time of ablation, nine patients had prior aortic valve replacement for a BAV. All but one patient had LGE-CMR and all patients underwent programmed ventricular stimulation at the time of the ablation. RESULTS: Frequent PVCs were the targeted VAs in 17/19 patients and VT in 2/19 patients. Monomorphic ventricular tachycardia (VT) was inducible in 6 patients. A total of 15 VTs were inducible (2.5 ± 1.0 VTs per patient with a mean cycle length of 322 ± 83 msec). LGE was present in 13 patients. Patients with inducible VT had larger borderzone and core scar compared to non-inducible patients (7.8 ± 2.1 cm3 vs. 2.5 ± 3.1 cm3 and 5.1 ± 2.6 cm3 vs. 1.9 ± 3.0 cm3, p-value < .05 for both). PVCs and VTs were mapped to the periaortic valve area in 12 patients and 4 patients, respectively. The PVC burden was reduced from 27 ± 13 to 3 ± 6 (p < .001) and the ejection fraction improved from 49 ± 13% to 55 ± 9% (p = .005). CONCLUSIONS: VAs in patients with BAV often originate from the perivalvular area and patients often have LGE and inducible VT. LGE may be due to ventricular remodeling secondary to the presence of BAV and harbors the arrhythmogenic substrate for VT.


Subject(s)
Bicuspid Aortic Valve Disease , Tachycardia, Ventricular , Humans , Male , Female , Middle Aged , Bicuspid Aortic Valve Disease/surgery , Bicuspid Aortic Valve Disease/physiopathology , Bicuspid Aortic Valve Disease/complications , Bicuspid Aortic Valve Disease/diagnostic imaging , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Aged , Adult , Aortic Valve/surgery , Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Catheter Ablation , Action Potentials , Heart Valve Diseases/physiopathology , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/complications , Heart Valve Diseases/surgery , Heart Rate , Treatment Outcome , Risk Factors , Predictive Value of Tests , Retrospective Studies , Electrophysiologic Techniques, Cardiac , Contrast Media/administration & dosage , Magnetic Resonance Imaging, Cine
16.
Cardiovasc Revasc Med ; 63: 16-20, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38233251

ABSTRACT

BACKGROUND: There continues to be debate regarding the superiority of transcatheter (TAVR) over surgical aortic valve replacement (SAVR) in patients with bicuspid aortic valves (BAV). We aimed to compare outcomes during readmissions in elderly patients with BAV who underwent SAVR or TAVR. METHODS: Patients 65 years or older with BAV who underwent TAVR or isolated SAVR were identified using the National Readmission Database from 2012 through 2018. We compared outcomes during readmissions within 90 days after discharge from the index surgery. Propensity score matching was performed to adjust the baseline differences. RESULTS: During the study period, 8555 and 1081 elderly patients with BAV underwent SAVR and TAVR, respectively. The number of patients who underwent TAVR went up by 179 % from 2012 to 2018. Propensity score matching yielded 573 patients in each group. A total of 111 (19.4 %) in the SAVR group and 125 (21.8 %) in the TAVR group were readmitted within 90 days after the index surgery (p = .31). The mortality during the readmissions within 90 days was equivalent between the two groups (0.9 % in the SAVR group vs. 3.2 % in the TAVR group, p = .22). However, the median hospital cost was approximately doubled in the TAVR group during the readmission (18,250 dollars vs. 9310 dollars in the SAVR group, p < .001). CONCLUSIONS: Readmission within 90 days was common in both groups. While the mortality during the readmissions after the surgery was equivalent between the two groups, hospital cost was significantly more expensive in the TAVR group.


Subject(s)
Aortic Valve , Bicuspid Aortic Valve Disease , Databases, Factual , Heart Valve Diseases , Heart Valve Prosthesis Implantation , Patient Readmission , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/economics , Male , Female , Aged , Treatment Outcome , Time Factors , Bicuspid Aortic Valve Disease/surgery , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/mortality , Bicuspid Aortic Valve Disease/physiopathology , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Risk Factors , United States , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis Implantation/economics , Retrospective Studies , Age Factors , Risk Assessment , Heart Valve Diseases/surgery , Heart Valve Diseases/mortality , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/physiopathology , Postoperative Complications/etiology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology
17.
Ann Biomed Eng ; 51(12): 2802-2811, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37573264

ABSTRACT

In this paper, we explored the use of deep learning for the prediction of aortic flow metrics obtained using 4-dimensional (4D) flow magnetic resonance imaging (MRI) using wearable seismocardiography (SCG) devices. 4D flow MRI provides a comprehensive assessment of cardiovascular hemodynamics, but it is costly and time-consuming. We hypothesized that deep learning could be used to identify pathological changes in blood flow, such as elevated peak systolic velocity ([Formula: see text]) in patients with heart valve diseases, from SCG signals. We also investigated the ability of this deep learning technique to differentiate between patients diagnosed with aortic valve stenosis (AS), non-AS patients with a bicuspid aortic valve (BAV), non-AS patients with a mechanical aortic valve (MAV), and healthy subjects with a normal tricuspid aortic valve (TAV). In a study of 77 subjects who underwent same-day 4D flow MRI and SCG, we found that the [Formula: see text] values obtained using deep learning and SCGs were in good agreement with those obtained by 4D flow MRI. Additionally, subjects with non-AS TAV, non-AS BAV, non-AS MAV, and AS could be classified with ROC-AUC (area under the receiver operating characteristic curves) values of 92%, 95%, 81%, and 83%, respectively. This suggests that SCG obtained using low-cost wearable electronics may be used as a supplement to 4D flow MRI exams or as a screening tool for aortic valve disease.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Deep Learning , Wearable Electronic Devices , Humans , Aortic Valve/diagnostic imaging , Retrospective Studies , Aortic Valve Stenosis/diagnostic imaging , Magnetic Resonance Imaging/methods , Bicuspid Aortic Valve Disease/diagnostic imaging , Hemodynamics
18.
Ann Biomed Eng ; 50(1): 1-15, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34993699

ABSTRACT

The clinical benefit of patient-specific modeling of heart valve disease remains an unrealized goal, often a result of our limited understanding of the in vivo milieu. This is particularly true in assessing bicuspid aortic valve (BAV) disease, the most common cardiac congenital defect in humans, which leads to premature and severe aortic stenosis or insufficiency (AS/AI). However, assessment of BAV risk for AS/AI on a patient-specific basis is hampered by the substantial degree of anatomic and functional variations that remain largely unknown. The present study was undertaken to utilize a noninvasive computational pipeline ( https://doi.org/10.1002/cnm.3142 ) that directly yields local heart valve leaflet deformation information using patient-specific real-time three-dimensional echocardiographic imaging (rt-3DE) data. Imaging data was collected for patients with normal tricuspid aortic valve (TAV, [Formula: see text]) and those with BAV ([Formula: see text] with fused left and right coronary leaflets and [Formula: see text] with fused right and non-coronary leaflets), from which the medial surface of each leaflet was extracted. The resulting deformation analysis resulted in, for the first time, quantified differences between the in vivo functional deformations of the TAV and BAV leaflets. Our approach was able to capture the complex, heterogeneous surface deformation fields in both TAV and BAV leaflets. We were able to identify and quantify differences in stretch patterns between leaflet types, and found in particular that stretches experienced by BAV leaflets during closure differ from those of TAV leaflets in terms of both heterogeneity as well as overall magnitude. Deformation is a key parameter in the clinical assessment of valvular function, and serves as a direct means to determine regional variations in structure and function. This study is an essential step toward patient-specific assessment of BAV based on correlating leaflet deformation and AS/AI progression, as it provides a means for assessing patient-specific stretch patterns.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Aorta , Aortic Valve/diagnostic imaging , Bicuspid Aortic Valve Disease/diagnostic imaging , Heart Valve Diseases/diagnostic imaging , Humans , Tricuspid Valve
19.
Am J Cardiol ; 163: 85-90, 2022 01 15.
Article in English | MEDLINE | ID: mdl-34799086

ABSTRACT

Bicuspid aortic valve (BAV) is a common congenital heart disease, with a 10-fold higher prevalence in first-degree relatives. BAV has different phenotypes based on the morphology of cusp fusion. These phenotypes are associated with different clinical courses and prognoses. Currently, the determinants of the valve phenotype are unknown. In this study we evaluated the role of genetics using familial cohorts. Patients with BAV and their first-degree relatives were evaluated by echocardiography. The concordance in BAV phenotype between pairs of family members was calculated and compared with the concordance expected by chance. We then performed a systematic literature review to identify additional reports and calculated the overall concordance rate. During the study period, 70 cases from 31 families and 327 sporadic cases were identified. BAV was diagnosed in 14% of the screened relatives. The proportions of the morphologies identified was: 12.3% for type 0, 66.2% for type 1-LR, 15.4% for type 1-RN, 4.6% for type 1-NL, and 1.5% for type 2. For the assessment of morphologic concordance, we included 120 pairs of first-degree relatives with BAV from our original cohort and the literature review. Concordance was found only in 62% of the pairs which was not significantly higher than expected by chance. In conclusion, our finding demonstrates intrafamilial variability in BAV morphology, suggesting that morphology is determined by factors other than Mendelian genetics. As prognosis differs by morphology, our findings may suggest that clinical outcomes may vary even between first-degree relatives.


Subject(s)
Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/genetics , Adult , Aged , Bicuspid Aortic Valve Disease/classification , Echocardiography , Family , Female , Humans , Male , Mass Screening , Middle Aged , Phenotype
20.
BMC Cardiovasc Disord ; 21(1): 590, 2021 12 07.
Article in English | MEDLINE | ID: mdl-34876008

ABSTRACT

BACKGROUND: Optimal projection is essential for valve deployment during transcatheter aortic valve implantation (TAVI). The purpose of this study was to propose an approach to predict optimal projection in TAVI candidates with different aortic valve anatomies. METHODS: 331 patients undergoing self-expanding TAVI were included and the so-called non-coronary cusp (NCC)-parallel technique was utilized, which generated the predicted projection by connecting NCC commissures on the transverse plane on the pre-procedural computed tomography images. RESULTS: 37.8% of the study cohort were bicuspid aortic valve (BAV) patients. Around 80% of both NCC-parallel views and final views were in the right anterior oblique (RAO) and caudal (CAU) quadrant. There was less than 5° change required from the NCC-parallel view to the final implanted view in 79% of tricuspid aortic valve (TAV) patients but only in 27% (13/48) of type 0 BAV patients with coronary arteries originated from the different cusps. After excluding the above mentioned BAV patients, 62.3% (48/77) of BAV patients needed less than 5° change to achieve optimal projection and only in 8 patients, the angular change was larger than 10° in either left/right anterior oblique or cranial/caudal direction. CONCLUSIONS: The NCC-parallel technique provides reliable prediction for optimal projection in self-expanding TAVI in all TAV and most BAV patients, with a vast majority of views in the RAO and CAU quadrant.


Subject(s)
Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/surgery , Multidetector Computed Tomography , Tomography, X-Ray Computed , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Anatomic Landmarks , Aortic Valve/abnormalities , Clinical Decision-Making , Female , Heart Valve Prosthesis , Humans , Male , Predictive Value of Tests , Prospective Studies , Prosthesis Design
SELECTION OF CITATIONS