Results 1 - 20 de 1.179
Filter
1.
Biochem Med (Zagreb) ; 34(2): 020704, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38665870

ABSTRACT

Introduction: Clinical laboratories should guarantee sample stability in specific storage conditions for further analysis. The aim of this study is to evaluate the stability of plasma samples under refrigeration for 29 common biochemical analytes usually ordered within an emergency context, in order to determine the maximum allowable period for conducting add-on testing. Materials and methods: A total of 20 patient samples were collected in lithium heparin tubes without gel separator. All analyses were performed using Alinity systems (Abbott Laboratories, Abbott Park, USA) and samples were stored at 2-8 °C. Measurements were conducted in primary plasma tubes at specific time points up to 48 hours, with an additional stability study in plasma aliquots extending the time storage up to 96 hours. The stability limit was estimated considering the total limit of change criteria. Results: Of the 29 studied parameters, 24 demonstrated stabilities within a 48-hour storage period in primary plasma tubes. However, five analytes: aspartate aminotransferase, glucose, lactate dehydrogenase, inorganic phosphate and potassium evidenced instability at different time points (7.9 hours, 2.7 hours, 2.9 hours, 6.2 hours and 4.7 hours, respectively). The stability study in plasma aliquots showed that all parameters remained stable for 96 hours, except lactate dehydrogenase, with a stability limit of 63 hours. Conclusions: A reduced stability of primary plasma samples was observed for five common biochemical analytes ordered in an emergency context. To ensure the quality of add-on testing for these samples, plasma aliquots provide stability for a longer period.


Subject(s)
Blood Specimen Collection , Humans , Blood Specimen Collection/standards , Blood Chemical Analysis/standards , Quality Control , Quality Assurance, Health Care , Aspartate Aminotransferases/blood , L-Lactate Dehydrogenase/blood , Plasma/chemistry , Specimen Handling/standards
2.
J Appl Lab Med ; 9(3): 512-525, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38384160

ABSTRACT

BACKGROUND: In addition to newborn screening, dried blood spots (DBSs) are used for a wide variety of analytes for clinical, epidemiological, and research purposes. Guidelines on DBS collection, storage, and transport are available, but it is suggested that each laboratory should establish its own acceptance criteria. METHODS: An optical scanning device was developed to assess the quality of DBSs received in the newborn screening laboratory from 11 maternity wards between 2013 and 2018. The algorithm was adjusted to agree with the visual examination consensus of experienced laboratory personnel. Once validated, the algorithm was used to categorize DBS specimens as either proper or improper. Improper DBS specimens were further divided based on 4 types of specimen defects. RESULTS: In total, 27 301 DBSs were analyzed. Compared with an annual DBS rejection rate of about 1%, automated scanning rejected 26.96% of the specimens as having at least one defect. The most common specimen defect was multi-spotting (ragged DBS, 19.13%). Among maternity wards, improper specimen rates varied greatly between 5.70% and 49.92%. CONCLUSIONS: Improper specimen rates, as well as the dominant type of defect(s), are mainly institution-dependent, with various maternity wards consistently showing specific patterns of both parameters over time. Although validated in agreement with experienced laboratory personnel consensus, automated analysis rejects significantly more specimens. While continuous staff training, specimen quality monitoring, and problem-reporting to maternities is recommended, a thorough quality assessment strategy should also be implemented by every newborn screening laboratory. An important role in this regard may be played by automation in the form of optical scanning devices.


Subject(s)
Algorithms , Dried Blood Spot Testing , Neonatal Screening , Humans , Neonatal Screening/methods , Neonatal Screening/standards , Infant, Newborn , Dried Blood Spot Testing/methods , Dried Blood Spot Testing/standards , Quality Assurance, Health Care , Quality Control , Blood Specimen Collection/methods , Blood Specimen Collection/standards
4.
Hematology ; 29(1): 2314871, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38346146

ABSTRACT

OBJECTIVE: To investigate the influence of the dead space in disposable blood sampling needle on activated partial thromboplastin time (APTT), FVIII level and pharmacokinetic (PK) profiles in children with hemophilia. METHODS: Children (<18 years) with severe hemophilia A were enrolled. After three days' washout-period, blood samples were collected at pre-dose, 1 h, 3 h, 9 h, 24 h and 48 h post-infusion. At each timepoint, two 2 mL vacuum tubes with 3.2% trisodium citrate were used. The first tube was signed as 'non-standard' (NS) and the second tube was signed as 'standard' (S). FVIII activities were evaluated by one-stage assay. WAPPS-Hemo was used to generate PK profiles like half-life time (t1/2), clearance (CL), trough level and time to 1, 2 and 5IU/dL after a dose of 50 ± 10IU/dL. The FVIII activities at 9 h and 24 h post-infusion were put into WAPPS and thus brought four combinations by true or biased FVIII level that used. RESULT: Compared with standard-collected blood samples, prolonged APTT results (P-values < 0.01) and decreased FVIII activity (P-values < 0.05) were revealed in those non-standard blood samples. The corresponding bias was in positive relation to both APTT-S (r = 0.44, P < 0.0001) and FVIII-S level(r = 0.68, P < 0.001). The FVIII bias percentage got larger as FVIII-S level reduced (r = -0.24, P < 0.01). During the four combinations of FVIII activity at 9 h and 24 h, statistically longer t1/2, lower CL and longer time to 1, 2 or 5IU/dL were observed in 9H-S&24H-S group and 9H-NS&24H-S group. CONCLUSION: While using vacuum tubes for clotting indicators and PK profiles, the dead space of blood sampling needle should be eliminated in advance.


Subject(s)
Blood Specimen Collection , Factor VIII , Hemophilia A , Partial Thromboplastin Time , Child , Humans , Blood Coagulation , Factor VIII/pharmacokinetics , Half-Life , Hemophilia A/blood , Hemophilia A/diagnosis , Needles , Partial Thromboplastin Time/standards , Blood Specimen Collection/standards
5.
Platelets ; 34(1): 2194445, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37041749

ABSTRACT

Tumor-educated platelets (TEPs) have been widely reported to have promising application potential; nonetheless, platelet isolation from peripheral blood is an important but neglected step in TEPs research for platelet-based liquid biopsy. In this article, we discussed some common influence factors for platelet isolation. To investigate the factors involved in platelet isolation, a prospective multicenter study was conducted on healthy Han Chinese adults (18 to 79 years of age). A total of 208 individuals were included in the final statistical analysis out of the 226 healthy volunteers who were prospectively enrolled from four hospitals. The primary study metric was the platelet recovery rate (PRR). The similar pattern was observed in the four hospitals, The PRR at room temperature (23°C±2°C) was slightly higher than the PRR at cold temperature (4°C±2°C). Moreover, the PRR gradually decreased as the storage time increased. The PRR for samples within 2 hours of storage is significantly higher than for samples beyond 2 hours (p < .05). Additionally, PRR was also affected by the equipment used in different centers. This study confirmed several factors that influence platelet isolation. In our study, we indicated that platelet isolation should be performed within two hours of peripheral blood draw and held at room temperature until isolation, and that centrifuge models should be fixed during the extraction process, which will further improve the research progress of platelet-based liquid biopsy in cancer.


What is the context? Globally, cancer is one of the leading cause of premature death. Early screening is important for cancer diagnosis and treatment and can even significantly lower cancer mortalityGlobally, cancer is one of the leading cause of premature death. Early screening is important for cancer diagnosis and treatment and can even significantly lower cancer mortalityFor the liquid biopsy, isolation is an important step. Early studies have explored the influencing factors of exosome, circulating tumor cells (CTCs), and other components extraction in liquid biopsy.Despite platelet also being an excellent source of liquid biopsy, few studies have explored the factors that influence platelet isolation.Considering the importance of platelet isolation in tumor-based platelet liquid biopsy, our aim is to optimize platelet isolation conditions as much as possible to obtain a high platelet recovery rate.What is new? In this study, we conducted a prospective multicenter study ofhealthy adults from four centers, combining whole blood with platelet-richplasma to investigate factors influencing platelet recovery rate (PRR) during platelet isolation.In our study, we indicated that platelet isolation should be performed within two hours at room temperature, and that centrifuge models should be fixed during the extraction process, which will further improve the research progress of platelet-based liquid biopsy in cancer.What is the impact? In future platelet-related studies, we should fix the sample storage temperature, storage time and centrifuge model in the process of platelet extraction, so as to reduce the variables affecting platelet extraction as much as possible and ensure the stable recovery rate of platelet extraction.


Subject(s)
Blood Platelets , Blood Specimen Collection , Cell Separation , Adult , Humans , China , Cold Temperature , Neoplasms/pathology , Prospective Studies , Adolescent , Young Adult , Middle Aged , Aged , Healthy Volunteers , Specimen Handling/methods , Specimen Handling/standards , Blood Specimen Collection/methods , Blood Specimen Collection/standards , Liquid Biopsy/methods , Cell Separation/methods
6.
S Afr Med J ; 112(2): 13503, 2022 Feb 01.
Article in English | MEDLINE | ID: mdl-35139991

ABSTRACT

BACKGROUND: Bloodstream infections are an important cause of mortality in children. Blood cultures (BCs) remain the primary means of identifying organisms and their antibiotic susceptibility profiles. A shortcoming of BCs is that up to 56% of positive cultures will represent contaminants. Poor adherence to standard practices applicable to BC sampling could explain an unacceptable contamination rate. OBJECTIVES: To determine: (i) the BC contamination rate in the departments of paediatrics and child health at two tertiary hospitals in central South Africa; and (ii) BC sampling practices among paediatric clinicians. METHODS: The author determined the prevalence of BC contamination by analysis of laboratory data for the period 1 May - 27 August 2019, and assessed possible factors contributing to BC contamination by surveying paediatric medical staff with a self-administered BC practices questionnaire. RESULTS: Of the 244 BCs reviewed, 25.4% were positive. The most commonly isolated pathogens were coagulase-negative staphylococci (CoNS) (33.3%), Escherichia coli (22.2%), Enterococcus faecium (16.7%) and Acinetobacter baumannii (11.1%). In total, 15.2% of the BCs yielded contaminants and 2.9% had polymicrobial growth. The most common contaminant was CoNS. Approximately 68% of clinicians were not aware of BC sampling guidelines, and even among those who were aware of the guidelines, non-compliance was reported. CONCLUSIONS: The BC contamination rate was higher than internationally accepted rates. Educating clinicians on specific BC sampling guidelines is strongly recommended to decrease the high rate of contamination observed in this study.


Subject(s)
Bacteremia/diagnosis , Blood Culture/standards , Blood Specimen Collection/standards , Specimen Handling/standards , Bacteremia/microbiology , Bacteriological Techniques/standards , Guidelines as Topic , Humans , Pediatrics , Prevalence , South Africa , Surveys and Questionnaires , Tertiary Care Centers
7.
Front Endocrinol (Lausanne) ; 12: 784706, 2021.
Article in English | MEDLINE | ID: mdl-34899614

ABSTRACT

Background: Adrenocorticotropic hormone (ACTH) is widely used in adrenal vein sampling (AVS) and can be administered as a bolus injection or continuous infusion. The optimal administration method has not been determined. We aimed to compare the effects of ACTH bolus with infusion on cannulation success, lateralization assessment and adverse events (AEs). Methods: Retrospectively collected data from patients with primary aldosteronism who underwent AVS with ACTH at a tertiary hospital in China. Rate of successful cannulation, lateralization index (LI), complete biochemical remission and AEs related to AVS were analyzed. Results: The study included 80 patients receiving ACTH bolus and 94 receiving infusions. The rate of successful cannulation was comparable between bolus and infusion groups (75/80, 93.4% vs 88/94, 93.6%). In those with successful cannulation, the bolus group had a higher selectivity index than the infusion group, while LI [6.4(1.8-17.5) vs. 7.6(2.0-27.8), P=0.48] and rate of complete biochemical remission (43/44, 97.7% vs 53/53, 100%, P=0.45) did not significantly differ between the two groups. One in the bolus and one patient in the infusion group had adrenal vein rupture but they recovered with conservative treatment. The bolus group reported more transient AEs such as palpitation (52.9% vs 2.2%) and abdominal discomfort (40.0% vs 2.2%) than the infusion group. Conclusions: Due to their similar effects on cannulation success and lateralization, but a lower rate of transient AEs in the infusion group, the continuous infusion method should be recommended for ACTH stimulation in AVS.


Subject(s)
Adrenal Glands/blood supply , Adrenocorticotropic Hormone/administration & dosage , Blood Specimen Collection/methods , Hyperaldosteronism/blood , Adrenal Glands/drug effects , Adult , Blood Specimen Collection/standards , Catheterization/methods , Catheterization/standards , Female , Humans , Hyperaldosteronism/drug therapy , Infusions, Intravenous , Injections, Intravenous , Male , Middle Aged , Retrospective Studies
8.
Anal Methods ; 13(47): 5756-5763, 2021 12 09.
Article in English | MEDLINE | ID: mdl-34816272

ABSTRACT

Blood screening is a fundamental part of disease diagnosis and monitoring health. Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy offers an innovative solution to streamlining the process, especially for multianalyte detection in aqueous samples. However, samples always undergo a storage phase before they are processed for testing and blood transfusion. In this study, we investigated the effect of standard storage procedures on the macromolecular composition of whole blood, and plasma collected in blood tubes for diagnostic purposes and initial screening of blood products. Periphery blood samples were collected from 10 volunteers and then stored for 14 days at 4 °C. Samples were stored as isolated plasma and whole blood to provide three different datasets, namely: (1) plasma stored independently, (2) plasma stored with other blood components and (3) whole blood. ATR-FTIR spectra of aqueous blood were acquired every 24 h from the time of collection on a portable ATR-FTIR spectrophotometer to monitor the evolution of the macromolecular composition in each blood component. Principal component analysis (PCA), partial least squares regression (PLS-R) and multi-curve resolution alternate least squares (MCR-ALS) models were built to study changes in the spectra with the storage time and identify the key bands. Isolated plasma stored without red blood cells (RBCs) showed no changes over the 14 day period indicating limited degradation. By contrast, plasma stored with the other blood components showed visual and spectroscopic signs of degradation including increasing lipid bands and the amide I and II bands from haemoglobin (Hb). Ideally, for the application of IR spectroscopy in blood diagnostics and for initial screening of blood products, whole blood and isolated red blood cells can be stored for a maximum of 4 days at 4 °C in lithium-heparin anticoagulant tubes prior to spectral analysis before any signs of degradation. Isolated plasma, on the other hand, can be stored for much longer periods and shows no evidence of degradation in the spectra after 14 days.


Subject(s)
Blood Specimen Collection , Blood , Quality Control , Spectroscopy, Fourier Transform Infrared , Ataxia Telangiectasia Mutated Proteins , Blood Specimen Collection/methods , Blood Specimen Collection/standards , Erythrocytes , Fourier Analysis , Humans , Least-Squares Analysis , Spectroscopy, Fourier Transform Infrared/methods
9.
Int J Lab Hematol ; 43(6): 1272-1283, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34581008

ABSTRACT

This guidance document has been prepared on behalf of the International Council for Standardization in Haematology (ICSH). The aim of the document is to provide guidance and recommendations for the processing of citrated blood samples for coagulation tests in clinical laboratories in all regions of the world. The following areas are included in this document: Sample transport including use of pneumatic tubes systems; clots in citrated samples; centrifugation; primary tube storage and stability; interfering substances including haemolysis, icterus and lipaemia; secondary aliquots-transport, storage and processing; preanalytical variables for platelet function testing. The following areas are excluded from this document, but are included in an associated ICSH document addressing collection of samples for coagulation tests in clinical laboratories; ordering tests; sample collection tube and anticoagulant; preparation of the patient; sample collection device; venous stasis before sample collection; order of draw when different sample types are collected; sample labelling; blood-to-anticoagulant ratio (tube filling); influence of haematocrit. The recommendations are based on published data in peer-reviewed literature and expert opinion.


Subject(s)
Blood Coagulation Tests/standards , Hematology/standards , Blood Coagulation Tests/methods , Blood Specimen Collection/methods , Blood Specimen Collection/standards , Hematology/methods , Humans , Laboratories, Clinical/standards , Reference Standards
10.
mSphere ; 6(4): e0133020, 2021 08 25.
Article in English | MEDLINE | ID: mdl-34259557

ABSTRACT

Fingerprick blood spotted onto filter paper offers an alternative to venous blood for use in population-based surveillance because it is comparatively inexpensive, acceptable, and easy to manage in the field. Prior studies have shown excellent agreement for immunoglobulin G (IgG) antibody detection from dried blood spots (DBS) and venous blood samples. However, much of this evidence is from high-income settings or laboratories where the samples were unlikely to be exposed to extreme temperatures and humidity, factors known to degrade DBS. We report the diagnostic accuracy of DBS collected using HemaSpot HF devices against venous sera in measuring measles- and rubella-specific IgG antibodies in a household serosurvey conducted in two districts in India. Paired serum and DBS samples collected by fingerprick were collected from women aged 15 to 50 years enrolled in a serosurvey in Palghar District of Maharashtra and Kanpur Nagar District of Uttar Pradesh in India. Specimen quality and volume were assessed in the laboratory. Samples were tested for antimeasles and antirubella IgG antibodies by an enzyme-linked immunosorbent assay (ELISA) (Euroimmun). Sensitivity of antibody detection by DBS was greater than 98%, and specificity was 90% and 98%, for measles and rubella IgG, respectively. Antibody concentrations were strongly correlated between paired specimens with adequate volume (measles R2 = 0.94; rubella R2 = 0.89). Although correlation was poor if DBS specimens had lower volumes, impact on qualitative results was minimal. This study showed DBS collected with HemaSpot HF devices can generate highly accurate results of measles- and rubella-specific IgG compared to sera in community-based surveys when protocols are optimized for DBS specimens. IMPORTANCE Dried blood spot (DBS) collection provides an easy, practical, and acceptable alternative to venous blood collection, especially for community-based studies, provided that results from DBS are accurate. We demonstrated high sensitivity and specificity for measles- and rubella-specific immunoglobulin G (IgG) with DBS collected via HemaSpot HF devices compared to serum samples. This is one of the largest community-based diagnostic accuracy studies of measles and rubella antibody testing with DBS and the first application we are aware of using HemaSpot HF device for measles and rubella serology. Results support the use of DBS in community-based serosurveillance.


Subject(s)
Blood Specimen Collection/methods , Blood Specimen Collection/standards , Dried Blood Spot Testing/standards , Measles/diagnosis , Rubella/diagnosis , Adolescent , Adult , Antibodies, Viral/blood , Blood Specimen Collection/instrumentation , Dried Blood Spot Testing/methods , Enzyme-Linked Immunosorbent Assay , Female , Humans , Immunoglobulin G/blood , Immunoglobulin M/blood , India/epidemiology , Measles/epidemiology , Measles/immunology , Middle Aged , Reproducibility of Results , Rubella/epidemiology , Rubella/immunology , Seroepidemiologic Studies , Young Adult
11.
Sci Rep ; 11(1): 14706, 2021 07 19.
Article in English | MEDLINE | ID: mdl-34282182

ABSTRACT

Diagnosis of pheochromocytomas and paragangliomas in patients receiving hemodialysis is troublesome. The aim of the study was to establish optimal conditions for blood sampling for mass spectrometric measurements of normetanephrine, metanephrine and 3-methoxytyramine in patients on hemodialysis and specific reference intervals for plasma metanephrines under the most optimal sampling conditions. Blood was sampled before and near the end of dialysis, including different sampling sites in 170 patients on hemodialysis. Plasma normetanephrine concentrations were lower (P < 0.0001) and metanephrine concentrations higher (P < 0.0001) in shunt than in venous blood, with no differences for 3-methoxytyramine. Normetanephrine, metanephrine and 3-methoxytyramine concentrations in shunt and venous blood were lower (P < 0.0001) near the end than before hemodialysis. Upper cut-offs for normetanephrine were 34% lower when the blood was drawn from the shunt and near the end of hemodialysis compared to blood drawn before hemodialysis. This study establishes optimal sampling conditions using blood from the dialysis shunt near the end of hemodialysis with optimal reference intervals for plasma metanephrines for the diagnosis of pheochromocytomas/paragangliomas among patients on hemodialysis.


Subject(s)
Blood Specimen Collection , Metanephrine/blood , Renal Dialysis , Adrenal Gland Neoplasms/blood , Adrenal Gland Neoplasms/diagnosis , Aged , Aged, 80 and over , Blood Chemical Analysis/methods , Blood Chemical Analysis/standards , Blood Specimen Collection/methods , Blood Specimen Collection/standards , Calibration , Dopamine/analogs & derivatives , Dopamine/analysis , Dopamine/blood , Female , Humans , Male , Metanephrine/analysis , Middle Aged , Paraganglioma/blood , Paraganglioma/diagnosis , Pheochromocytoma/blood , Pheochromocytoma/diagnosis , Poland , Pre-Analytical Phase/methods , Pre-Analytical Phase/standards , Reference Values , Tandem Mass Spectrometry/methods , Tandem Mass Spectrometry/standards
13.
Int J Lab Hematol ; 43(4): 571-580, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34097805

ABSTRACT

This guidance document has been prepared on behalf of the International Council for Standardisation in Haematology (ICSH). The aim of the document is to provide guidance and recommendations for collection of blood samples for coagulation tests in clinical laboratories throughout the world. The following processes will be covered: ordering tests, sample collection tube and anticoagulant, patient preparation, sample collection device, venous stasis before sample collection, order of draw when different sample types need to be collected, sample labelling, blood-to-anticoagulant ratio (tube filling) and influence of haematocrit. The following areas are excluded from this document, but are included in an associated ICSH document addressing processing of samples for coagulation tests in clinical laboratories: sample transport and primary tube sample stability; centrifugation; interfering substances including haemolysis, icterus and lipaemia; secondary aliquots-transport and storage; and preanalytical variables for platelet function testing. The recommendations are based on published data in peer-reviewed literature and expert opinion.


Subject(s)
Blood Specimen Collection/standards , Blood Coagulation Tests/standards , Humans , Practice Guidelines as Topic , Reference Standards
14.
Clin Biochem ; 95: 49-53, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34077758

ABSTRACT

BACKGROUND: The management of affected results in haemolysed samples (HS) is debated. In an infant-maternity setting, for reporting interfered test results, we provided the result itself, the degree of haemolysis (as free haemoglobin concentration), and a warning recommending sample recollection. We investigated the impact of this approach on sample quality and clinicians' decision-making. METHODS: Free haemoglobin was measured on Beckman Coulter AU680 as haemolytic index. We estimated the total HS number, the clinical wards more affected by HS, the most interfered analytes, and the retesting rate of interfered tests, by comparing data from Apr-Dec 2017, the period just after the introduction of the new policy, vs. Apr-Dec 2018. RESULTS: One year after the new report introduction, a significant HS decrease (5.8% vs. 7.8%, P < 0.001) was detected, together with a reduction of the frequency by which haemolysis affected results. The most affected wards, i.e., Paediatric and Neonatal Intensive Care Units, showed an improvement in sample quality (HS rate, 30.6% to 16.1%, P < 0.001, and 25.2% to 20.9%, P = 0.048, respectively). We noted a significant decrease in retesting after an alerted result for aspartate aminotransferase, magnesium, potassium, conjugated bilirubin, and lactate dehydrogenase. CONCLUSIONS: Our approach led to a HS decrease, suggesting that the provided report could be a driving force for improvement of phlebotomy quality, also helping clinicians in deciding if retesting is essential or not.


Subject(s)
Blood Chemical Analysis/standards , Blood Specimen Collection/standards , Chemistry, Clinical/methods , Chemistry, Clinical/standards , Hemolysis , Hospitals, Maternity , Specimen Handling/standards , Blood Specimen Collection/statistics & numerical data , Hemoglobins/analysis , Humans , Obstetrics , Patients' Rooms , Specimen Handling/statistics & numerical data
15.
GMS J Med Educ ; 38(1): Doc23, 2021.
Article in English | MEDLINE | ID: mdl-33659628

ABSTRACT

The COVID-19 pandemic has led to a short-term sharp increase in the demand for auxiliary staff in emergency rooms and intensive care units. Against this background student tutors of the Medical Faculty Erlangen have developed a training concept. The aim was to familiarize students in the clinical section quickly and effectively with skills that are particularly important in a clinical assignment as (student) assistant in the care of corona patients (e.g.: personal protective equipment, intubation assistance, arterial blood collection, assessment of blood gas values and ventilation parameters). In a blended learning concept, learning materials were prepared in advance and then implemented and deepened in a presence phase. The selection of learning materials and the low supervision ratio (1:2) made it possible to realize an internally differentiated approach. The offer met with great interest among students of all clinical semesters and was evaluated very positively. The skills learned can be applied widely even independently of a pandemic.


Subject(s)
COVID-19/epidemiology , COVID-19/therapy , Education, Medical/organization & administration , Health Workforce/organization & administration , Students, Medical , Blood Specimen Collection/standards , Humans , Intubation, Intratracheal/methods , Pandemics , Personal Protective Equipment/supply & distribution , SARS-CoV-2
16.
Transfusion ; 61(6): 1955-1965, 2021 06.
Article in English | MEDLINE | ID: mdl-33738810

ABSTRACT

BACKGROUND: Avoidable human error is a significant cause of transfusion adverse events. Adequately trained, laboratory staff in blood establishments and blood banks, collectively blood facilities, are key in ensuring high-quality transfusion medicine (TM) services. Gaps in TM education and training of laboratory staff exist in most African countries. We assessed the status of the training and education of laboratory staff working in blood facilities in Africa. STUDY DESIGN AND METHODS: A cross-sectional study using a self-administered pilot-tested questionnaire was performed. The questionnaire comprised 26 questions targeting six themes. Blood facilities from 16 countries were invited to participate. Individually completed questionnaires were grouped by country and descriptive analysis performed. RESULTS: Ten blood establishments and two blood banks from eight African countries confirmed the availability of a host of training programs for laboratory staff; the majority of which were syllabus or curriculum-guided and focused on both theoretical and practical laboratory skills development. Training was usually preplanned, dependent on student and trainer availability and delivered through lecture-based classroom training as well as formal and informal on the job training. There were minimal online didactic and self-directed learning. Teaching of humanistic values appeared to be lacking. CONCLUSION: We confirmed the availability of diverse training programs across a variety of African countries. Incorporation of virtual learning platforms, rather than complete reliance on didactic, in-person training programs may improve the education reach of the existing programs. Digitalization driven by the coronavirus disease 2019 pandemic may provide an opportunity to narrow the knowledge gap in low- and middle-income countries (LMICs).


Subject(s)
Blood Banking , Blood Banks , Health Knowledge, Attitudes, Practice , Medical Laboratory Personnel/education , Transfusion Medicine/education , Adult , Africa/epidemiology , Blood Banks/standards , Blood Specimen Collection/methods , Blood Specimen Collection/standards , COVID-19/blood , COVID-19/epidemiology , COVID-19/prevention & control , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Retrospective Studies , SARS-CoV-2 , Surveys and Questionnaires , Transfusion Medicine/standards , Blood Banking/methods
17.
Arch Pediatr ; 28(3): 191-196, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33707101

ABSTRACT

INTRODUCTION: Pediatrics is one of the medical specialties in which blood cultures for bloodstream infections are performed very frequently. This study aimed to evaluate pediatric residents' knowledge and perceptions of blood culture sampling. MATERIAL AND METHODS: Between June 2019 and September 2019, a questionnaire comprising 20 questions about blood culture sampling was sent via email to participants who were pediatric residents at five different hospitals in Turkey. There were 11 true/false and nine multiple-choice questions that assessed three aspects of culture sampling: indications, sampling practice and knowledge, and contamination. The percentage of correct answers was used to calculate an overall score and subsection scores. RESULTS: A total of 132 pediatric residents [102 (77%) female] with a mean age of 28.3±2.8 years completed the questionnaire. Forty-five (35%) were in their 1st year of residency. Sixty (46%) participants reported that they had not performed blood culture sampling in the last week. There was a negative relationship between years in training and the number of cultures performed (Kendal's tau-b=-0.297, p<0.001). The overall median score was 65 (range, 35-90) and it seemed to increase with years of training. The lowest median score was in the contamination subscale and only one (0.76%) participant correctly answered all questions concerning contamination. CONCLUSION: Residents who obtained the majority of blood cultures had the lowest knowledge levels. Therefore, it is evident that the knowledge levels of pediatric residents must be increased in order to improve blood culture sampling practices in centers where they perform blood culture sampling.


Subject(s)
Attitude of Health Personnel , Blood Culture/statistics & numerical data , Blood Specimen Collection/statistics & numerical data , Clinical Competence/statistics & numerical data , Internship and Residency , Pediatrics/education , Practice Patterns, Physicians'/statistics & numerical data , Adult , Bacteremia/blood , Bacteremia/diagnosis , Blood Culture/methods , Blood Culture/standards , Blood Specimen Collection/standards , Clinical Decision-Making , Diagnostic Errors , False Positive Reactions , Female , Humans , Male , Pediatrics/standards , Practice Patterns, Physicians'/standards , Turkey , Unnecessary Procedures
19.
Lab Med ; 52(2): 197-201, 2021 Mar 15.
Article in English | MEDLINE | ID: mdl-32789453

ABSTRACT

OBJECTIVE: Sodium fluoride (NaF) has been applied to inhibit glycolysis in venous specimens for decades. However, it has had little effect on the rate of glycolysis in the first 1 to 2 hours, resulting in a decrease of glucose, so a more efficient method is needed. Recently, we discovered that WZB117, a specific Glut1 inhibitor, restricts glycolysis by inhibiting the passive sugar transport of human red blood cells and cancer cells. The purpose of this study was to evaluate the results of intravenous blood glucose determination after the addition of WZB117. METHODS: Venous specimens from 40 pairs of healthy volunteers were collected for several days and placed in tubes containing NaF plus EDTA-disodium (Na2) without WZB117 (the A group); citric acid, trisodium citrate, and EDTA-Na2 without WZB117 (B group); and NaF plus EDTA-Na2 with WZB117 (C group). The glucose concentration was measured after venipuncture and compared with test tubes treated for 1 hour, 2 hours, and 3 hours before centrifugation. Glucose level was determined by the hexokinase method. The paired t-test was used to examine differences in glucose values at baseline and at different time points. The number of misdiagnoses and the misdiagnosis rate were calculated at 2 diagnostic stages: high risk of diabetes (glucose level of 6.1 mmol/L) and diagnosis of diabetes (glucose level of 7.0 mmol/L). RESULTS: Glucose levels decreased by 1.0% at 1 hour and by 2.1% at 3 hours in the C group tubes and simultaneously decreased by 1.7% at 1 hour and by 2.5% at 3 hours in the B group tubes. In contrast, glucose levels decreased by 4.1% at 1 hour and by 6.3% at 3 hours in the A group tubes. There was a statistically significant difference in glucose levels measured in the A group tubes and B group tubes at 1 hour, 2 hours, and 3 hours. The misdiagnosis rate of clinical diagnosis in diabetes was highest in the A group tubes (7.0‰ at 1 hour, 0.1‰ at 3 hours at 7.0 mmol/L point; 14.6‰ at 1 hour, 0.4‰ at 3 hours at 6.1 mmol/L point) and lowest in the C group tubes (2.95‰ at 1 hour, 0‰ at 3 hours at 7.0 mmol/L point; 4.8‰ at 1 hour, 0.1‰ at 3 hours at 6.1 mmol/L point). CONCLUSION: The tube addition of WZB117 is more suitable for minimizing glycolysis and has no effect on glucose levels even if specimens are left uncentrifuged for up to 3 hours.


Subject(s)
Blood Glucose/analysis , Blood Specimen Collection/methods , Blood Specimen Collection/standards , Glucose Transporter Type 1/antagonists & inhibitors , Hydroxybenzoates/pharmacology , Adult , Blood Chemical Analysis/methods , Blood Chemical Analysis/standards , Female , Glycolysis/drug effects , Humans , Male , Sodium Fluoride , Young Adult
20.
Placenta ; 103: 50-52, 2021 01 01.
Article in English | MEDLINE | ID: mdl-33075720

ABSTRACT

Umbilical cord blood is an important graft source in the treatment of many genetic, hematologic, and immunologic disorders by hematopoietic stem cell transplantation. Millions of cord blood units have been collected and stored for clinical use since the inception of cord blood banking in 1989. However, the use of cord blood in biomedical research has been limited by access to viable samples. Here, we present a cost-effective, self-sustaining model for the procurement of fresh umbilical cord blood components for research purposes within hospital-affiliated academic institutions.


Subject(s)
Biomedical Research/organization & administration , Blood Banks/organization & administration , Fetal Blood , Models, Organizational , Academies and Institutes/economics , Academies and Institutes/organization & administration , Academies and Institutes/standards , Biomedical Research/economics , Biomedical Research/methods , Biomedical Research/standards , Blood Banks/economics , Blood Banks/standards , Blood Specimen Collection/economics , Blood Specimen Collection/methods , Blood Specimen Collection/standards , California , Cost-Benefit Analysis , Female , Fetal Blood/cytology , Fetal Blood/transplantation , Hematopoietic Stem Cell Transplantation/economics , Hematopoietic Stem Cell Transplantation/methods , Hematopoietic Stem Cell Transplantation/standards , Humans , Infant, Newborn , Pregnancy