Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 10.701
Filter
1.
BJS Open ; 8(3)2024 May 08.
Article in English | MEDLINE | ID: mdl-38768283

ABSTRACT

BACKGROUND: Extended aortic repair is considered a key issue for the long-term durability of surgery for DeBakey type 1 aortic dissection. The risk of aortic degeneration may be higher in young patients due to their long life expectancy. The early outcome and durability of aortic surgery in these patients were investigated in the present study. METHODS: The subjects of the present analysis were patients under 60 years old who underwent surgical repair for acute DeBakey type 1 aortic dissection at 18 cardiac surgery centres across Europe between 2005 and 2021. Patients underwent ascending aortic repair or total aortic arch repair using the conventional technique or the frozen elephant trunk technique. The primary outcome was 5-year cumulative incidence of reoperation on the distal aorta. RESULTS: Overall, 915 patients underwent surgical ascending aortic repair and 284 patients underwent surgical total aortic arch repair. The frozen elephant trunk procedure was performed in 128 patients. Among 245 propensity score-matched pairs, total aortic arch repair did not decrease the rate of distal aortic reoperation compared to ascending aortic repair (5-year cumulative incidence, 6.7% versus 6.7%, subdistributional hazard ratio 1.127, 95% c.i. 0.523 to 2.427). Total aortic arch repair increased the incidence of postoperative stroke/global brain ischaemia (25.7% versus 18.4%, P = 0.050) and dialysis (19.6% versus 12.7%, P = 0.003). Five-year mortality was comparable after ascending aortic repair and total aortic arch repair (22.8% versus 27.3%, P = 0.172). CONCLUSIONS: In patients under 60 years old with DeBakey type 1 aortic dissection, total aortic arch replacement compared with ascending aortic repair did not reduce the incidence of distal aortic operations at 5 years. When feasible, ascending aortic repair for DeBakey type 1 aortic dissection is associated with satisfactory early and mid-term outcomes. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04831073.


Subject(s)
Aorta, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Postoperative Complications , Reoperation , Humans , Aortic Dissection/surgery , Aortic Dissection/mortality , Male , Female , Middle Aged , Aorta, Thoracic/surgery , Reoperation/statistics & numerical data , Postoperative Complications/epidemiology , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/mortality , Adult , Retrospective Studies , Treatment Outcome , Europe/epidemiology , Propensity Score
3.
BMC Cardiovasc Disord ; 24(1): 239, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38714966

ABSTRACT

OBJECTIVE: Cerebral malperfusion (CM) is a common comorbidity in acute type A aortic dissection (ATAAD), which is associated with high mortality and poor neurological prognosis. This meta-analysis investigated the surgical strategy of ATAAD patients with CM, aiming to compare the difference in therapeutic effectiveness between the central repair-first and the early reperfusion-first according to clinical outcomes. METHODS: The meta-analysis and systematic review was conducted based on studies sourced from the PubMed, Embase, and Cochrane literature database, in which cases of ATAAD with CM underwent surgical repair were included. Data for baseline characteristics, mortality, survival were extracted, and risk ratio (RR) values and the pooled mortality were calculated. RESULTS: A total of 17 retrospective studies were analyzed, including 1010 cases of ATAAD with CM underwent surgical repair. The pooled early mortality in early reperfusion group was lower (8.1%; CI, 0.02 to 0.168) than that in the central repair group (16.2%; CI, 0.115 to 0.216). The pooled long-term mortality was 7.9% in the early reperfusion cohort and 17.4% the central repair-first cohort, without a statistically significant heterogeneity (I [2] = 51.271%; p = 0.056). The mean time of symptom-onset-to-the-operation-room in all the reports was 8.87 ± 12.3 h. CONCLUSION: This meta-analysis suggested that early reperfusion-first may achieved better outcomes compared to central repair-first in ATAAD patients complicated with CM to some extent. Early operation and early restoration of cerebral perfusion may reduce the occurrence of some neurological complications. TRIAL REGISTRATION: The meta-analysis was registered in the International Prospective Register of Systematic Reviews database (No. CRD CRD42023475629) on Nov. 8th, 2023.


Subject(s)
Aortic Aneurysm , Aortic Dissection , Cerebrovascular Circulation , Humans , Aortic Dissection/surgery , Aortic Dissection/mortality , Aortic Dissection/complications , Aortic Dissection/physiopathology , Aortic Dissection/diagnostic imaging , Treatment Outcome , Risk Factors , Time Factors , Aortic Aneurysm/surgery , Aortic Aneurysm/mortality , Aortic Aneurysm/complications , Aortic Aneurysm/physiopathology , Aortic Aneurysm/diagnostic imaging , Female , Male , Middle Aged , Aged , Acute Disease , Cerebrovascular Disorders/surgery , Cerebrovascular Disorders/etiology , Cerebrovascular Disorders/mortality , Cerebrovascular Disorders/diagnosis , Cerebrovascular Disorders/physiopathology , Adult , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Risk Assessment , Reperfusion , Time-to-Treatment
4.
Article in English | MEDLINE | ID: mdl-38749718

ABSTRACT

PURPOSE: Achieving a secure anastomosis and complete hemostasis is essential for surgically treating type A acute aortic dissection (TAAAD). This study assessed the clinical feasibility of "tailored stand-up collar (TSC)" technique for constructing the distal stump. METHODS: We enrolled 68 patients who underwent ascending aortic repair for TAAAD. Patients were categorized according to the technique for distal stump construction: conventional (C) group using only a felt strip (32 cases); post-aortotomy (P) group, with a Hydrofit-felt strip attached after aortotomy (18 cases), and TSC group, where a Hydrofit-felt strip attached during cooling (18 cases). Pre-operative characteristics, procedural profiles, and post-operative outcomes were evaluated. RESULTS: The pre-operative characteristics were identical among the groups. The durations of cardiopulmonary bypass, hemostasis, and surgery were significantly shorter in the P and TSC groups. The duration of open distal in the TSC group (21 min) was significantly shorter than the other two groups. Post-operative additional procedures were not required for the TSC group and their post-operative hospital stay was significantly shorter (47.1% of patients were discharged within 2 weeks). CONCLUSION: The TSC technique would be practical because of its high reproducibility in terms of ease of use, shorter anastomotic time, and secure hemostasis.


Subject(s)
Aortic Dissection , Blood Vessel Prosthesis Implantation , Feasibility Studies , Length of Stay , Humans , Aortic Dissection/surgery , Aortic Dissection/diagnostic imaging , Female , Male , Treatment Outcome , Middle Aged , Aged , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Time Factors , Acute Disease , Retrospective Studies , Operative Time , Aortic Aneurysm/surgery , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Adult , Postoperative Complications/etiology
5.
J Cardiothorac Surg ; 19(1): 170, 2024 Apr 02.
Article in English | MEDLINE | ID: mdl-38566230

ABSTRACT

BACKGROUND: Open repair of thoracoabdominal aortic aneurysm (TAAA) was characterized by significant risk of postoperative mortality and morbidity. The aim of this study was to determine the perioperative predictors of early and long-term mortality in patients undergoing open repair of TAAA. Besides, the postoperative outcomes in patients with open repair of TAAA were described. METHODS: This is a single-center retrospective study, and 146 patients with open repair of TAAA from January 4, 2011, to November 22, 2018 was involved. Categorical variables were analyzed by the Chi-square test or Fisher's exact test, and continuous variables were analyzed by the independent sample t-test and the WilCoxon rank-sum test. Multivariate Logistic regression and Cox regression were applied to identify the predictors of 30-day and long-term mortality, respectively. The Kaplan Meier curves were used to illustrate survival with the Log-rank test. RESULTS: The 30-day mortality was 9.59% (n = 14). Older than 50 years, the intraoperative volume of red blood cell (RBC) and epinephrine use were independently associated with postoperative 30-day mortality in open repair of TAAA. Long-term mortality was 17.12% (n = 25) (median of 3.5 years (IQR = 2-5 years) of follow-up). Prior open thoracoabdominal aortic aneurysm (TAAA) repair, aortic cross-clamping (ACC) time, intraoperative volume of RBC and use of epinephrine were independently correlated with long-term mortality. CONCLUSIONS: Identifying perioperative risk factors of early and long-term mortaliy is crucial for surgeons. Intraoperative volume of RBC and use of epinephrine were predictors of both early and long-term mortality. In addition, patients of advanced age, prior open repair of TAAA and prolonged ACC time should be paid more attention.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Aneurysm, Thoracoabdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Aortic Aneurysm, Thoracic/complications , Treatment Outcome , Retrospective Studies , Blood Vessel Prosthesis Implantation/adverse effects , Risk Factors , Epinephrine , Postoperative Complications/etiology , Endovascular Procedures/adverse effects , Risk Assessment
6.
Sci Rep ; 14(1): 8057, 2024 04 05.
Article in English | MEDLINE | ID: mdl-38580650

ABSTRACT

The potential of adverse events (AEs) after thoracic endovascular aortic repair (TEVAR) in patients with type B aortic dissection (TBAD) has been reported. To avoid the occurrence of AEs, it is important to recognize high-risk population for prevention in advance. The data of 261 patients with TBAD who received TEVAR between June 2017 and June 2021 at our medical center were retrospectively reviewed. After the implementation of exclusion criteria, 172 patients were finally included, and after 2.8 years (range from 1 day to 5.8 years) of follow up, they were divided into AEs (n = 41) and non-AEs (n = 131) groups. We identified the predictors of AEs, and a prediction model was constructed to calculate the specific risk of postoperative AEs at 1, 2, and 3 years, and to stratify patients into high-risk (n = 78) and low-risk (n = 94) group. The prediction model included seven predictors: Age > 75 years, Lower extremity malperfusion (LEM), NT-proBNP > 330 pg/ml, None distal tear, the ratio between the diameter of the ascending aorta and descending aorta (A/D ratio) > 1.2, the ratio of the area of the false lumen to the total aorta (FL ratio) > 64%, and acute TEVAR, which exhibited excellent predictive accuracy performance and discriminatory ability with C statistic of 82.3% (95% CI 77.3-89.2%). The prediction model was contributed to identify high-risk patients of postoperative AEs, which may serve to achievement of personalized treatment and follow-up plans for patients.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Aged , Endovascular Aneurysm Repair , Blood Vessel Prosthesis Implantation/adverse effects , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/etiology , Retrospective Studies , Endovascular Procedures/adverse effects , Treatment Outcome , Time Factors , Aorta, Thoracic/surgery , Aortic Dissection/surgery , Risk Factors
7.
J Cardiothorac Surg ; 19(1): 226, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38627818

ABSTRACT

BACKGROUND: Sex-related dissimilarities' influence on outcomes following thoracic aortic surgery is poorly understood. Our aim is to examine sex-related disparities in patients undergoing thoracic aortic aneurysm (TAA). METHODS: A total of 455 cases undergoing thoracic aortic aneurysm (TAA) surgery were consecutively enrolled between December 2009 and December 2015 in a Chinese hospital. Primary outcomes, including overall mortality and related risk factors, were evaluated. Cox regression is utilized to recognize the independent risk factor of these consequences. RESULTS: Females, compared to males, had greater indexed aortic diameters and higher aortic transvalvular pressure differences. For the location of aortic aneurysms, females had a higher rate of aortic arch involvement, while males had a higher rate of root involvement. Females underwent less frequent complex proximal aortic operations compared with males (29.5% versus 46.9%; p < 0.001). Women and men both had a lower rate of aortic transvalvular pressure difference and LV volume index 7 days after thoracic aortic surgery. The overall mortality for the women's groups (11%) was suggestively greater compared to 4.9% for the men's groups (p = 0.026). Renal failure and aortic arch involvement were the main risk factors associated with males' survival, while maximum indexed aortic diameter and cross-clamp time were the risk factors associated with females' survival. CONCLUSIONS: The outcome after TAA surgery was less favorable in women with significantly increased overall mortality. It highlights the need to focus on implementing personalized surgery strategies and gender-specific guidelines in treating female patients following TAA surgery.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Thoracic Surgical Procedures , Male , Humans , Female , Retrospective Studies , Aortic Aneurysm, Thoracic/etiology , Aorta, Thoracic/surgery , Risk Factors , Treatment Outcome , Blood Vessel Prosthesis Implantation/adverse effects
8.
Catheter Cardiovasc Interv ; 103(6): 1074-1077, 2024 May.
Article in English | MEDLINE | ID: mdl-38577923

ABSTRACT

Transcatheter aortic valve implantation (TAVI) has traditionally been indicated for the treatment of aortic stenosis. However, in this case report, we describe a successful TAVI procedure in a 46-year-old male patient who had previously undergone David aortic valve-sparing aortic root replacement for type 1 aortic dissection. The patient presented with aortic valve insufficiency 4 years after the initial surgery and was subsequently treated with a 34 mm Medtronic CoreValve Evolut R prosthesis via TAVI. This case highlights the feasibility of TAVI as a viable treatment option for postoperative aortic valve insufficiency in patients with prior ascending aortic or aortic arch surgery.


Subject(s)
Aortic Dissection , Aortic Valve Insufficiency , Aortic Valve , Blood Vessel Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aortic Dissection/surgery , Aortic Dissection/diagnostic imaging , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/physiopathology , Middle Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Prosthesis Design , Blood Vessel Prosthesis , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm/surgery , Aortic Aneurysm/diagnostic imaging , Aortography
9.
Arterioscler Thromb Vasc Biol ; 44(5): 1065-1085, 2024 May.
Article in English | MEDLINE | ID: mdl-38572650

ABSTRACT

Blood vessels are subjected to complex biomechanical loads, primarily from pressure-driven blood flow. Abnormal loading associated with vascular grafts, arising from altered hemodynamics or wall mechanics, can cause acute and progressive vascular failure and end-organ dysfunction. Perturbations to mechanobiological stimuli experienced by vascular cells contribute to remodeling of the vascular wall via activation of mechanosensitive signaling pathways and subsequent changes in gene expression and associated turnover of cells and extracellular matrix. In this review, we outline experimental and computational tools used to quantify metrics of biomechanical loading in vascular grafts and highlight those that show potential in predicting graft failure for diverse disease contexts. We include metrics derived from both fluid and solid mechanics that drive feedback loops between mechanobiological processes and changes in the biomechanical state that govern the natural history of vascular grafts. As illustrative examples, we consider application-specific coronary artery bypass grafts, peripheral vascular grafts, and tissue-engineered vascular grafts for congenital heart surgery as each of these involves unique circulatory environments, loading magnitudes, and graft materials.


Subject(s)
Blood Vessel Prosthesis , Hemodynamics , Humans , Animals , Models, Cardiovascular , Prosthesis Failure , Stress, Mechanical , Biomechanical Phenomena , Mechanotransduction, Cellular , Blood Vessel Prosthesis Implantation/adverse effects , Prosthesis Design , Graft Occlusion, Vascular/physiopathology , Graft Occlusion, Vascular/etiology , Vascular Remodeling
10.
J Cardiovasc Surg (Torino) ; 65(2): 85-98, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38635284

ABSTRACT

Endovascular aortic repair (EVAR) is nowadays the establishment treatment for patients with abdominal aortic aneurysm (AAA) both in elective and urgent setting. Despite the large applicability and satisfactory results, the presence of hostile iliac anatomy affects both technical and clinical success. This narrative review aimed to report the impact of iliac access and related adjunctive procedures in patients undergoing EVAR in elective and non-elective setting. Hostile iliac access can be defined in presence of narrowed, tortuous, calcified, or occluded iliac arteries. These iliac characteristics can be graded by the anatomic severity grade score to quantitatively assess anatomic complexity before undergoing treatment. Literature shows that iliac hostility has an impact on device navigability, insertion and perioperative and postoperative results. Overall, it has been correlated to higher rate of access issues, representing up to 30% of the first published EVAR experience. Recent innovations with low-profile endografts have reduced large-bore sheaths related issues. However, iliac-related complications still represent an issue, and several adjunctive endovascular and surgical strategies are nowadays available to overcome these complications during EVAR. In urgent settings iliac hostility can significantly impact on particular time sensitive procedures. Moreover, in case of severe hostility patients might be written off for EVAR repair might be inapplicable, exposing to higher mortality/morbidity risk in this urgent/emergent setting. In conclusion, an accurate anatomical evaluation of iliac arteries during preoperative planning, materials availability, and skilled preparation to face iliac-related issues are crucial to address these challenges.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Elective Surgical Procedures , Endovascular Procedures , Iliac Artery , Humans , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Iliac Artery/surgery , Iliac Artery/diagnostic imaging , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Treatment Outcome , Risk Factors , Blood Vessel Prosthesis , Postoperative Complications/etiology
11.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38597899

ABSTRACT

OBJECTIVES: Our goal was to review our surgical experiences in patients with complex pathologies of the aortic arch who have undergone anterolateral thoracotomy with a partial sternotomy (ALPS). METHODS: From October 2019 to November 2023, a total of 23 patients underwent one-stage repairs of complex pathologies of the aortic arch through the ALPS approach. The mean age was 61.9 ± 16.7 years old. The aortic pathologies were as follows: aorta-related infection in 11 (aorto-oesophageal fistula: 4, graft infection: 6, native aortic infection: 1); aortic dissection in 9 including shaggy aorta in 2, non-dissecting aneurysm in 1, and coarctation of the aorta (CoA) in 2. RESULTS: Eighteen patients underwent aortic replacement from either the sinotubular junction or the ascending aorta to the descending aorta; 1 patient underwent it from the aortic root to the descending aorta (redo Bentall procedure and extensive aortic arch replacement); 3 patients underwent it from the aortic arch between the left carotid artery and left subclavian artery to the descending aorta; and 1 patient underwent a descending aortic replacement. Ten patients underwent omentopexy, latissimus dorsi muscle flap installation or both procedures. The hospital mortality rate was 13.0% (3/23). The overall survival and freedom from aortic events were 73.3%±10.2% and 74.1%±10.2%, respectively, at the 3-year follow-up. There was an absence of aorta-related deaths, and no recurrent infections were identified. CONCLUSIONS: The short-term outcomes using the ALPS approach for the treatment of complex pathologies of the aortic arch were acceptable. Further studies will be required to determine the long-term results.


Subject(s)
Aorta, Thoracic , Sternotomy , Thoracotomy , Humans , Thoracotomy/methods , Aorta, Thoracic/surgery , Middle Aged , Male , Sternotomy/methods , Female , Aged , Retrospective Studies , Aortic Diseases/surgery , Adult , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/adverse effects , Feasibility Studies , Treatment Outcome
12.
J Cardiovasc Surg (Torino) ; 65(2): 119-123, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38618696

ABSTRACT

This article summarizes the key findings in literature up to date on the endovascular treatment of complex abdominal aortic aneurysms (AAAs) employing the chimney technique. Additionally, an unexplored pitfall is described regarding the target vessel angulation. Although balloon-expandable covered stents present more favorable configuration in downward-oriented target vessels, transverse and upward-oriented target vessels may benefit from other endovascular techniques imploring careful case planning and further investigation on the topic.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Renal Artery , Stents , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Humans , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Renal Artery/surgery , Renal Artery/diagnostic imaging , Treatment Outcome , Endovascular Procedures/instrumentation , Prosthesis Design , Risk Factors
13.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38569918

ABSTRACT

OBJECTIVES: Our goal was to access early and mid-term outcomes of a gutter-plugging chimney stent graft for treatment of Stanford type B aortic dissections in the clinical trial Prospective Study for Aortic Arch Therapy with stENt-graft for Chimney technology (PATENCY). METHODS: Between October 2018 and March 2022, patients with Stanford type B aortic dissections were treated with the Longuette chimney stent graft in 26 vascular centres. The efficiency and the incidence of adverse events over 12 months were investigated. RESULTS: A total of 150 patients were included. The technical success rate was 99.33% (149/150). The incidence of immediate postoperative endoleak was 5.33% (8/150, type I, n = 6; type II, n = 1; type IV, n = 1) neurologic complications (stroke or spinal cord ischaemia); the 30-day mortality was 0.67% (1/150) and 1.33% (2/150), respectively. During the follow-up period, the median follow-up time was 11.67 (5-16) months. The patent rate of the Longuette graft was 97.87%. Two patients with type I endoleak underwent reintervention. The follow-up rate of the incidence of retrograde A type aortic dissection was 0.67% (1/150). There was no paraplegia, left arm ischaemia or stent migration. CONCLUSIONS: For revascularization of the left subclavian artery, the Longuette chimney stent graft can provide an easily manipulated, safe and effective endovascular treatment. It should be considered a more efficient technique to prevent type Ia endoleak. Longer follow-up and a larger cohort are needed to validate these results. CLINICAL TRIAL REGISTRY NUMBER: NCT03767777.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endovascular Procedures , Stents , Adult , Aged , Female , Humans , Male , Middle Aged , Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/instrumentation , Endovascular Procedures/methods , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Prospective Studies , Prosthesis Design , Stents/adverse effects , Treatment Outcome , Case-Control Studies
14.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38598445

ABSTRACT

OBJECTIVES: The indications for use, evidence base and experience with the novel noncovered open hybrid surgical stents for acute type A aortic dissection repair for concurrent stabilization of the 'downstream' aorta remains limited. We review the evidence base and the development of these stents. METHODS: Data were collected from Pubmed/Medline literature search to develop and review the evidence base for safety and efficacy of non-covered surgical stents. Existing guidelines for use and developments were reviewed. RESULTS: A single randomized control trial and 4 single-centre studies were included in the review with a total worldwide experience of 241 patients. The deployment was easy and did not add significantly to the primary operation. The mortality and new stroke ranged from 6.3-18.7%. Safe and complete deployment was accomplished in 92-100%. There was no device-related reintervention. There was a significant improvement in malperfusion in over 90% of the cases with varying degrees of remodelling (60-90%) of the downstream aorta. CONCLUSIONS: Open noncovered stent grafts represent a major technical advancement as an adjunct procedure for acute dissection repairs, e.g. hemiarch repair. It has potential for wider use by non-aortic surgeons due to simplicity of technique. Limited safety and efficacy data confirm the device to be safe, feasible and reproducible with potential for wider adoption. However, long-term trial and registry data are required before recommendations for standard use outside of high-volume experienced aortic centres.


Subject(s)
Aortic Dissection , Blood Vessel Prosthesis Implantation , Stents , Humans , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/methods , Endovascular Procedures/adverse effects , Acute Disease , Prosthesis Design , Aortic Aneurysm, Thoracic/surgery , Treatment Outcome , Aortic Aneurysm/surgery
15.
J Cardiovasc Surg (Torino) ; 65(2): 124-131, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38635285

ABSTRACT

INTRODUCTION: We performed a systematic review and meta-analysis to assess the existing published evidence regarding the safety and efficacy of the endovascular aortic repair with chimney technique (ch-EVAR) and physician-modified stent-grafts (PMSGs) for the treatment of pararenal aortic aneurysm repair. EVIDENCE ACQUISITION: A systematic search of all relevant studies reported until October 2023 according to the PRISMA (preferred reporting items for systematic reviews and meta-analyses) guidelines was performed. The pooled 30-day mortality, peri- and postoperative complication rates were estimated using fixed or random effect methods. EVIDENCE SYNTHESIS: A total of 679 study titles were identified by the initial search strategy, of which 16 were considered eligible for inclusion in the meta-analysis. A total of 1094 patients (ch-EVAR N.=861 and PMSG N.=233) (90% male) were identified. The pooled 30-day mortality rate was 3.4% for ch-EVAR and 2.6% for PMSG. The major adverse events (MAE) in the early period was 14.7% for ch-EVAR and 18.5% PMSG, respectively. Higher occlusion rate was observed of the chimney stents grafts (8.2%) than the bridging stents (1.4%) during the follow-up period. CONCLUSIONS: Ch-EVAR and physician-modified technology are safe with low 30-day mortality in elective settings for pararenal aortic aneurysms repair. No significant differences were seen between the two surgical methods regarding the early major adverse events rate. However, higher occlusion rate for the chimneys can be expected over time.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endovascular Procedures , Postoperative Complications , Prosthesis Design , Stents , Humans , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Endovascular Procedures/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Treatment Outcome , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/mortality , Aortic Aneurysm, Abdominal/diagnostic imaging , Postoperative Complications/etiology , Risk Factors , Male , Female , Aged , Time Factors , Risk Assessment , Middle Aged
16.
J Cardiovasc Surg (Torino) ; 65(2): 110-118, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38635286

ABSTRACT

BACKGROUND: The aim of this study was to evaluate the anatomical feasibility of current available fenestrated endografts (FEVAR) and on-label chimney technique (EnChEVAR) in patients with complex abdominal aortic aneurysms (C-AAA). METHODS: Feasibility of EnChEVAR (Endurant II/IIS CE-marked [Medtronic]) and 4 types of FEVAR (Zenith Fenestrated CE-marked, Zenith Fenestrated Low-Profile [LP] custom-made device [CMD] [Cook Medical], Fenestrated Anaconda LoPro90 CMD, Fenestrated Treo CMD [Terumo Aortic]) was assessed according to the manufacturer's instructions for use. Computed tomography angiograms of patients with C-AAA previously included in the Protagoras 2.0 study were retrospectively reviewed. The aortic coverage was ideally planned to involve a maximum of two chimney grafts or fenestrations. RESULTS: Iliac access and aortic neck of 73 C-AAAs were analyzed. The overall feasibility was significantly different between EnChEVAR (33%) and FEVAR (Zenith Fenestrated 15%, Zenith Fenestrated LP 15%, Fenestrated Anaconda LoPro90 45%, Fenestrated Treo 48%). The iliac access feasibility was significantly lower for Zenith Fenestrated with standard profile compared to all other grafts. The aortic neck feasibility was significantly higher for EnChEVAR and both Terumo Aortic fenestrated stent grafts, compared to both Cook Medical grafts. The treatment using any of the three current available fenestrated grafts with lower profile (Zenith Fenestrated LP, Fenestrated Anaconda LoPro90, Fenestrated Treo) would have been feasible in 71% of the cases. CONCLUSIONS: Most of the patients treated by ChEVAR would have not been treated by first generation fenestrated stent graft. The current available fenestrated endografts, with lower profile and suitable also for angulated necks, increase the anatomical feasibility.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Computed Tomography Angiography , Endovascular Procedures , Feasibility Studies , Prosthesis Design , Stents , Humans , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Endovascular Procedures/instrumentation , Endovascular Procedures/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Retrospective Studies , Female , Male , Aged , Treatment Outcome , Aged, 80 and over , Contrast Media , Aortography
18.
J Cardiovasc Surg (Torino) ; 65(2): 106-109, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38635287

ABSTRACT

BACKGROUND: The aim of this study was to evaluate the early results of the CE-marked standardized device combination consisting of Endurant and the Radiant chimney graft (En-ChEVAR) for the treatment of juxtarenal aortic aneurysms. METHODS: We analyzed multicentric non-industry sponsored case series evaluating the EnChEVAR technique for patients treated between December 2022 and February 2024. Clinical, perioperative procedure-related and radiological data were collected. The primary outcome measure was the freedom of a type Ia gutter-related endoleak at postoperative computed tomography angiography (CTA). Secondary outcome measures included early type Ia endoleak-related reinterventions, target vessel complications including dissection or loss of target vessel, major adverse events, and mortality. Continuous variables were presented as median (interquartile range [IQR]) and categorical variables as count and percentage. RESULTS: Ten patients were included in the present study. Eight (80%) were males, in nine cases a single chimney was implanted, and the other one was a double chimney graft placement. The treated aneurysms had an infrarenal neck length of 3.4 (1.2) mm. The rate of main body oversizing was 30%. The new neck length after chimney graft placement was 18 (3) mm. The median procedural time was 130 (17) mm, contrast medium use was 109 (26) mL, radiation time was 45 (12) min. The technical success was 100%. No type Ia endoleak was detected at the postoperative CTA. There were no target vessel issues. No major adverse events or death were observed. CONCLUSIONS: First reported cohort of patients treated with EnChEVAR demonstrated reproducible clinical and procedural outcomes within the 3 vascular centers with total exclusion of the aneurysms, patent renal arteries, and no evidence of gutter-related type IA endoleak. Further evidence with larger sample size of treated patients and longer follow-up are needed.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endoleak , Endovascular Procedures , Prosthesis Design , Registries , Humans , Male , Female , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Aged , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/mortality , Endoleak/etiology , Time Factors , Treatment Outcome , Aged, 80 and over , Stents , Retrospective Studies , Risk Factors , Product Labeling , Endovascular Aneurysm Repair
19.
Kyobu Geka ; 77(2): 136-139, 2024 Feb.
Article in Japanese | MEDLINE | ID: mdl-38459863

ABSTRACT

A 67-year-old male was admitted to our hospital for sudden onset chest pain and hoarseness. He underwent 2-debranching thoracic endovascular aortic repair for a ruptured aortic arch aneurysm four years prior. However, computed tomography (CT) revealed an aneurysmal rerupture due to a typeⅠa endoleak. We performed partial arch replacement with uncovered stent removal under intermittent hypothermic circulatory arrest. We needed to be more careful than usual open heart surgery because a non-anatomical bypass procedure was performed. The surgery was successful without any major complications, and the patient was discharged on the 23th postoperative day. Reinterventions post-endovascular repair are sometimes difficult;thus, open surgery could be useful for arch replacement.


Subject(s)
Aneurysm, Aortic Arch , Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Male , Humans , Aged , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/surgery , Endovascular Aneurysm Repair , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/complications , Blood Vessel Prosthesis Implantation/adverse effects , Stents/adverse effects , Treatment Outcome , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Blood Vessel Prosthesis/adverse effects , Retrospective Studies
20.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38439540

ABSTRACT

OBJECTIVES: Thoracic endovascular aortic repair (TEVAR) for aortic arch aneurysms is challenging because of anatomical restrictions and the presence of cervical branches. Revascularization of the cervical branch is required when conventional commercial stent grafts are used. TEVAR using fenestrated stent grafts (FSG) often does not require additional procedures to revascularize cervical branches. This study aimed to evaluate the features and initial and midterm outcomes of TEVAR using fenestrated stent grafts. METHODS: From April 2007 to December 2016, 101 consecutive patients underwent TEVAR using fenestrated stent grafts for distal aortic arch aneurysms at a single centre. Technical success, complications, freedom from aneurysm-related death, secondary intervention and aneurysm progression were retrospectively investigated. RESULTS: All the patients underwent TEVAR using fenestrated stent grafts. The 30-day mortality rate was zero. Cerebral infarction, access route problems and spinal cord injury occurred in 4, 3 and 2 patients, respectively. Each type of endoleak was observed in 38 of the 101 patients during the course of the study; 20/38 patients had minor type 1 endoleaks at the time of discharge. The endoleak disappeared in 2 patients and showed no significant change in 8 patients; however, the aneurysm expanded over time in 10 patients. Additional treatment was performed in 8 of the 10 patients with type 1 endoleaks and dilatation of the aneurysm. The rate of freedom from aneurysm-related death during the observation period was 98%. CONCLUSIONS: TEVAR with FSG is a simple procedure, with few complications. Additional treatment has been observed to reduce aneurysm-related deaths, even in patients with endoleaks and enlarged aneurysms. Based on this study, the outcomes of endovascular repair of aortic arch aneurysms using a fenestrated stent graft seem acceptable.


Subject(s)
Aneurysm, Aortic Arch , Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Blood Vessel Prosthesis , Endovascular Aneurysm Repair , Endoleak/etiology , Stents , Blood Vessel Prosthesis Implantation/adverse effects , Retrospective Studies , Treatment Outcome , Endovascular Procedures/adverse effects , Prosthesis Design , Time Factors , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/etiology
SELECTION OF CITATIONS
SEARCH DETAIL
...