Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 7.245
Filter
1.
J Cardiovasc Surg (Torino) ; 65(2): 119-123, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38618696

ABSTRACT

This article summarizes the key findings in literature up to date on the endovascular treatment of complex abdominal aortic aneurysms (AAAs) employing the chimney technique. Additionally, an unexplored pitfall is described regarding the target vessel angulation. Although balloon-expandable covered stents present more favorable configuration in downward-oriented target vessels, transverse and upward-oriented target vessels may benefit from other endovascular techniques imploring careful case planning and further investigation on the topic.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Renal Artery , Stents , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Humans , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Renal Artery/surgery , Renal Artery/diagnostic imaging , Treatment Outcome , Endovascular Procedures/instrumentation , Prosthesis Design , Risk Factors
2.
J Cardiovasc Surg (Torino) ; 65(2): 124-131, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38635285

ABSTRACT

INTRODUCTION: We performed a systematic review and meta-analysis to assess the existing published evidence regarding the safety and efficacy of the endovascular aortic repair with chimney technique (ch-EVAR) and physician-modified stent-grafts (PMSGs) for the treatment of pararenal aortic aneurysm repair. EVIDENCE ACQUISITION: A systematic search of all relevant studies reported until October 2023 according to the PRISMA (preferred reporting items for systematic reviews and meta-analyses) guidelines was performed. The pooled 30-day mortality, peri- and postoperative complication rates were estimated using fixed or random effect methods. EVIDENCE SYNTHESIS: A total of 679 study titles were identified by the initial search strategy, of which 16 were considered eligible for inclusion in the meta-analysis. A total of 1094 patients (ch-EVAR N.=861 and PMSG N.=233) (90% male) were identified. The pooled 30-day mortality rate was 3.4% for ch-EVAR and 2.6% for PMSG. The major adverse events (MAE) in the early period was 14.7% for ch-EVAR and 18.5% PMSG, respectively. Higher occlusion rate was observed of the chimney stents grafts (8.2%) than the bridging stents (1.4%) during the follow-up period. CONCLUSIONS: Ch-EVAR and physician-modified technology are safe with low 30-day mortality in elective settings for pararenal aortic aneurysms repair. No significant differences were seen between the two surgical methods regarding the early major adverse events rate. However, higher occlusion rate for the chimneys can be expected over time.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endovascular Procedures , Postoperative Complications , Prosthesis Design , Stents , Humans , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Endovascular Procedures/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Treatment Outcome , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/mortality , Aortic Aneurysm, Abdominal/diagnostic imaging , Postoperative Complications/etiology , Risk Factors , Male , Female , Aged , Time Factors , Risk Assessment , Middle Aged
3.
J Cardiovasc Surg (Torino) ; 65(2): 110-118, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38635286

ABSTRACT

BACKGROUND: The aim of this study was to evaluate the anatomical feasibility of current available fenestrated endografts (FEVAR) and on-label chimney technique (EnChEVAR) in patients with complex abdominal aortic aneurysms (C-AAA). METHODS: Feasibility of EnChEVAR (Endurant II/IIS CE-marked [Medtronic]) and 4 types of FEVAR (Zenith Fenestrated CE-marked, Zenith Fenestrated Low-Profile [LP] custom-made device [CMD] [Cook Medical], Fenestrated Anaconda LoPro90 CMD, Fenestrated Treo CMD [Terumo Aortic]) was assessed according to the manufacturer's instructions for use. Computed tomography angiograms of patients with C-AAA previously included in the Protagoras 2.0 study were retrospectively reviewed. The aortic coverage was ideally planned to involve a maximum of two chimney grafts or fenestrations. RESULTS: Iliac access and aortic neck of 73 C-AAAs were analyzed. The overall feasibility was significantly different between EnChEVAR (33%) and FEVAR (Zenith Fenestrated 15%, Zenith Fenestrated LP 15%, Fenestrated Anaconda LoPro90 45%, Fenestrated Treo 48%). The iliac access feasibility was significantly lower for Zenith Fenestrated with standard profile compared to all other grafts. The aortic neck feasibility was significantly higher for EnChEVAR and both Terumo Aortic fenestrated stent grafts, compared to both Cook Medical grafts. The treatment using any of the three current available fenestrated grafts with lower profile (Zenith Fenestrated LP, Fenestrated Anaconda LoPro90, Fenestrated Treo) would have been feasible in 71% of the cases. CONCLUSIONS: Most of the patients treated by ChEVAR would have not been treated by first generation fenestrated stent graft. The current available fenestrated endografts, with lower profile and suitable also for angulated necks, increase the anatomical feasibility.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Computed Tomography Angiography , Endovascular Procedures , Feasibility Studies , Prosthesis Design , Stents , Humans , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Endovascular Procedures/instrumentation , Endovascular Procedures/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Retrospective Studies , Female , Male , Aged , Treatment Outcome , Aged, 80 and over , Contrast Media , Aortography
4.
J Cardiovasc Surg (Torino) ; 65(2): 106-109, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38635287

ABSTRACT

BACKGROUND: The aim of this study was to evaluate the early results of the CE-marked standardized device combination consisting of Endurant and the Radiant chimney graft (En-ChEVAR) for the treatment of juxtarenal aortic aneurysms. METHODS: We analyzed multicentric non-industry sponsored case series evaluating the EnChEVAR technique for patients treated between December 2022 and February 2024. Clinical, perioperative procedure-related and radiological data were collected. The primary outcome measure was the freedom of a type Ia gutter-related endoleak at postoperative computed tomography angiography (CTA). Secondary outcome measures included early type Ia endoleak-related reinterventions, target vessel complications including dissection or loss of target vessel, major adverse events, and mortality. Continuous variables were presented as median (interquartile range [IQR]) and categorical variables as count and percentage. RESULTS: Ten patients were included in the present study. Eight (80%) were males, in nine cases a single chimney was implanted, and the other one was a double chimney graft placement. The treated aneurysms had an infrarenal neck length of 3.4 (1.2) mm. The rate of main body oversizing was 30%. The new neck length after chimney graft placement was 18 (3) mm. The median procedural time was 130 (17) mm, contrast medium use was 109 (26) mL, radiation time was 45 (12) min. The technical success was 100%. No type Ia endoleak was detected at the postoperative CTA. There were no target vessel issues. No major adverse events or death were observed. CONCLUSIONS: First reported cohort of patients treated with EnChEVAR demonstrated reproducible clinical and procedural outcomes within the 3 vascular centers with total exclusion of the aneurysms, patent renal arteries, and no evidence of gutter-related type IA endoleak. Further evidence with larger sample size of treated patients and longer follow-up are needed.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endoleak , Endovascular Procedures , Prosthesis Design , Registries , Humans , Male , Female , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Aged , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/mortality , Endoleak/etiology , Time Factors , Treatment Outcome , Aged, 80 and over , Stents , Retrospective Studies , Risk Factors , Product Labeling , Endovascular Aneurysm Repair
5.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38603631

ABSTRACT

When neither surgical valve replacement nor transcatheter aortic valve implantation is possible, performing an apico-aortic conduit remains a therapeutic option. This procedure has become rare and the rigid angled apical connectors usually used to facilitate ventricular anastomosis are no longer commercially available. We described the technique that we performed on a 60-year-old patient with readily available material.


Subject(s)
Aortic Valve , Humans , Middle Aged , Aortic Valve/surgery , Male , Aorta/surgery , Aortic Valve Stenosis/surgery , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/instrumentation
6.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38569918

ABSTRACT

OBJECTIVES: Our goal was to access early and mid-term outcomes of a gutter-plugging chimney stent graft for treatment of Stanford type B aortic dissections in the clinical trial Prospective Study for Aortic Arch Therapy with stENt-graft for Chimney technology (PATENCY). METHODS: Between October 2018 and March 2022, patients with Stanford type B aortic dissections were treated with the Longuette chimney stent graft in 26 vascular centres. The efficiency and the incidence of adverse events over 12 months were investigated. RESULTS: A total of 150 patients were included. The technical success rate was 99.33% (149/150). The incidence of immediate postoperative endoleak was 5.33% (8/150, type I, n = 6; type II, n = 1; type IV, n = 1) neurologic complications (stroke or spinal cord ischaemia); the 30-day mortality was 0.67% (1/150) and 1.33% (2/150), respectively. During the follow-up period, the median follow-up time was 11.67 (5-16) months. The patent rate of the Longuette graft was 97.87%. Two patients with type I endoleak underwent reintervention. The follow-up rate of the incidence of retrograde A type aortic dissection was 0.67% (1/150). There was no paraplegia, left arm ischaemia or stent migration. CONCLUSIONS: For revascularization of the left subclavian artery, the Longuette chimney stent graft can provide an easily manipulated, safe and effective endovascular treatment. It should be considered a more efficient technique to prevent type Ia endoleak. Longer follow-up and a larger cohort are needed to validate these results. CLINICAL TRIAL REGISTRY NUMBER: NCT03767777.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endovascular Procedures , Stents , Adult , Aged , Female , Humans , Male , Middle Aged , Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/instrumentation , Endovascular Procedures/methods , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Prospective Studies , Prosthesis Design , Stents/adverse effects , Treatment Outcome , Case-Control Studies
7.
Catheter Cardiovasc Interv ; 103(6): 1074-1077, 2024 May.
Article in English | MEDLINE | ID: mdl-38577923

ABSTRACT

Transcatheter aortic valve implantation (TAVI) has traditionally been indicated for the treatment of aortic stenosis. However, in this case report, we describe a successful TAVI procedure in a 46-year-old male patient who had previously undergone David aortic valve-sparing aortic root replacement for type 1 aortic dissection. The patient presented with aortic valve insufficiency 4 years after the initial surgery and was subsequently treated with a 34 mm Medtronic CoreValve Evolut R prosthesis via TAVI. This case highlights the feasibility of TAVI as a viable treatment option for postoperative aortic valve insufficiency in patients with prior ascending aortic or aortic arch surgery.


Subject(s)
Aortic Dissection , Aortic Valve Insufficiency , Aortic Valve , Blood Vessel Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aortic Dissection/surgery , Aortic Dissection/diagnostic imaging , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/physiopathology , Middle Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Prosthesis Design , Blood Vessel Prosthesis , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm/surgery , Aortic Aneurysm/diagnostic imaging , Aortography
8.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38598445

ABSTRACT

OBJECTIVES: The indications for use, evidence base and experience with the novel noncovered open hybrid surgical stents for acute type A aortic dissection repair for concurrent stabilization of the 'downstream' aorta remains limited. We review the evidence base and the development of these stents. METHODS: Data were collected from Pubmed/Medline literature search to develop and review the evidence base for safety and efficacy of non-covered surgical stents. Existing guidelines for use and developments were reviewed. RESULTS: A single randomized control trial and 4 single-centre studies were included in the review with a total worldwide experience of 241 patients. The deployment was easy and did not add significantly to the primary operation. The mortality and new stroke ranged from 6.3-18.7%. Safe and complete deployment was accomplished in 92-100%. There was no device-related reintervention. There was a significant improvement in malperfusion in over 90% of the cases with varying degrees of remodelling (60-90%) of the downstream aorta. CONCLUSIONS: Open noncovered stent grafts represent a major technical advancement as an adjunct procedure for acute dissection repairs, e.g. hemiarch repair. It has potential for wider use by non-aortic surgeons due to simplicity of technique. Limited safety and efficacy data confirm the device to be safe, feasible and reproducible with potential for wider adoption. However, long-term trial and registry data are required before recommendations for standard use outside of high-volume experienced aortic centres.


Subject(s)
Aortic Dissection , Blood Vessel Prosthesis Implantation , Stents , Humans , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/methods , Endovascular Procedures/adverse effects , Acute Disease , Prosthesis Design , Aortic Aneurysm, Thoracic/surgery , Treatment Outcome , Aortic Aneurysm/surgery
9.
J Cardiovasc Surg (Torino) ; 65(2): 85-98, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38635284

ABSTRACT

Endovascular aortic repair (EVAR) is nowadays the establishment treatment for patients with abdominal aortic aneurysm (AAA) both in elective and urgent setting. Despite the large applicability and satisfactory results, the presence of hostile iliac anatomy affects both technical and clinical success. This narrative review aimed to report the impact of iliac access and related adjunctive procedures in patients undergoing EVAR in elective and non-elective setting. Hostile iliac access can be defined in presence of narrowed, tortuous, calcified, or occluded iliac arteries. These iliac characteristics can be graded by the anatomic severity grade score to quantitatively assess anatomic complexity before undergoing treatment. Literature shows that iliac hostility has an impact on device navigability, insertion and perioperative and postoperative results. Overall, it has been correlated to higher rate of access issues, representing up to 30% of the first published EVAR experience. Recent innovations with low-profile endografts have reduced large-bore sheaths related issues. However, iliac-related complications still represent an issue, and several adjunctive endovascular and surgical strategies are nowadays available to overcome these complications during EVAR. In urgent settings iliac hostility can significantly impact on particular time sensitive procedures. Moreover, in case of severe hostility patients might be written off for EVAR repair might be inapplicable, exposing to higher mortality/morbidity risk in this urgent/emergent setting. In conclusion, an accurate anatomical evaluation of iliac arteries during preoperative planning, materials availability, and skilled preparation to face iliac-related issues are crucial to address these challenges.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Elective Surgical Procedures , Endovascular Procedures , Iliac Artery , Humans , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Iliac Artery/surgery , Iliac Artery/diagnostic imaging , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Treatment Outcome , Risk Factors , Blood Vessel Prosthesis , Postoperative Complications/etiology
10.
J Cardiovasc Surg (Torino) ; 65(2): 99-105, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38551514

ABSTRACT

The initial success and widespread adoption of endovascular aneurysm repair (EVAR) for the treatment of abdominal aortic aneurysms have been tempered by numerous reports of secondary interventions and increased long-term mortality compared with open repair. Over the past decade, several studies on postoperative sac dynamics after EVAR have suggested that the presence of sac regression is a benign feature with a favorable prognosis. Conversely, increasing sacs and even stable sacs can be indicators of more unstable sac behavior with worse outcomes in the long-term. Endoleaks were initially perceived as the main drivers of sac behavior. However, the observation that sac regression can occur in the presence of endoleaks, and vice versa - increasing sacs without evidence of endoleak - on imaging studies, suggests the involvement of other contributing factors. These factors can be divided into anatomical factors, patient characteristics, sac thrombus composition, and device-related factors. The shift of interest away from especially type 2 endoleaks is further supported by promising results with the use of EndoAnchors regarding postoperative sac behavior. This review provides an overview of the existing literature on the implications and known risk factors of post-EVAR sac behavior, describes the accurate measurement of sac behavior, and discusses the use of EndoAnchors to promote sac regression.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endoleak , Endovascular Procedures , Humans , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endoleak/etiology , Risk Factors , Treatment Outcome , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Prosthesis Design
12.
Ann Vasc Surg ; 103: 122-132, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38387799

ABSTRACT

BACKGROUND: In endovascular aortic repair (EVAR), preemptive embolization of sac branch vessels is effective in preventing postoperative type II endoleak (T2EL). However, this technique has not been widely adopted especially for lumbar arteries (LAs) because of technical difficulties and time constraints. This study aimed to investigate the efficacy of nonselective sac coil embolization, which is a simpler surgical method, in postoperative sac shrinkage for patients at a high risk of T2EL from LAs. METHODS: We retrospectively assessed 76 patients who underwent elective EVAR for abdominal aortic aneurysm with 4 or more patent LAs or at least 1 patent LA of ≥2 mm at our hospital between January 2014 and December 2022. The patients who underwent sac coil embolization were included in Group Ⅰ (n = 20), and the others were divided into 2 groups: those with an inferior mesenteric artery that was originally occluded or embolized by coils or stent graft bodies (Group Ⅱ, n = 21), and those without that (Group Ⅲ, n = 35). In Group Ⅰ, 0.035-inch coils were inserted into the sac after complete stent graft deployment. The cumulative incidence of sac shrinkage (≥5 mm) was compared between the groups. Further, univariable and multivariable Cox regression analyses were used to determine the predictors of sac shrinkage. RESULTS: Sac shrinkage (≥5 mm) was observed more frequently in Group Ⅰ (50%) than in Group Ⅱ (19%) and Group Ⅲ (17%) (P = 0.052 and 0.043, respectively). The cumulative incidence of sac shrinkage was significantly higher in Group Ⅰ than in Group Ⅱ (log-rank P = 0.039) and Group Ⅲ (log-rank P = 0.024). Multivariable Cox regression analyses revealed that sac embolization was a significant predictor of sac shrinkage (hazard ratio, 4.23; 95% confidence interval, 1.66-10.8; P = 0.003). CONCLUSIONS: Nonselective sac coil embolization in EVAR is potentially effective for sac shrinkage in the early postoperative phase in patients at high risk of T2EL from LAs. This simple procedure may improve prognosis after EVAR.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Embolization, Therapeutic , Endoleak , Endovascular Procedures , Humans , Endoleak/etiology , Endoleak/prevention & control , Endoleak/therapy , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Male , Retrospective Studies , Embolization, Therapeutic/adverse effects , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Aged , Female , Risk Factors , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Treatment Outcome , Aged, 80 and over , Time Factors , Risk Assessment , Blood Vessel Prosthesis , Stents , Endovascular Aneurysm Repair
13.
Ann Vasc Surg ; 103: 74-80, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38395342

ABSTRACT

BACKGROUND: Transcarotid artery revascularization (TCAR) is a hybrid technique with excellent initial outcomes. The technical success and safety of TCAR is heavily dependent on an anatomically suitable common carotid artery (CCA). Many patients do not meet anatomic criteria and therefore are not eligible for this therapy. We sought to extend the eligibility of TCAR to patients with unfavorable CCA anatomy via the adoption of a prosthetic arterial conduit. METHODS: A single-center retrospective study of patients with critical carotid artery stenosis who underwent TCAR via a prosthetic conduit between June 2019 and October 2021 was performed. All patients in the study were considered high-risk for carotid endarterectomy based on anatomic features, such as restenosis post-carotid endarterectomy and neck radiation. Unfavorable CCA anatomy was defined as a clavicle to carotid bifurcation distance <5 cm, a CCA diameter <6 mm, and/or significant atherosclerotic disease at the intended arterial access site. The primary outcome of interest was technical success. Secondary outcomes included perioperative complications, intermediate and long-term patency, intermediate and long-term stroke and/or mortality and in-hospital length of stay. Follow-up ranged from 1 to 29 months. RESULTS: Eight patients underwent 10 TCAR procedures via a prosthetic conduit. A total of 2 procedures (20%) were performed on female patients and 8 procedures (75%) were performed on male patients. The mean age was 65 years old (standard deviation 11 years). Technical success was 100%. The 30-day ipsilateral stroke rate was 0%. The 30-day patency was 90%. There was no re-exploration for hemorrhage and 30 day mortality was 0%. CONCLUSIONS: TCAR is an excellent option for carotid artery revascularization. Unfavorable CCA anatomy has limited its applicability. TCAR via a prosthetic conduit has the potential to expand eligibility for this promising therapy.


Subject(s)
Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Carotid Artery, Common , Carotid Stenosis , Feasibility Studies , Vascular Patency , Humans , Male , Female , Retrospective Studies , Aged , Treatment Outcome , Carotid Stenosis/diagnostic imaging , Carotid Stenosis/surgery , Carotid Stenosis/mortality , Time Factors , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Middle Aged , Carotid Artery, Common/surgery , Carotid Artery, Common/diagnostic imaging , Carotid Artery, Common/physiopathology , Risk Factors , Prosthesis Design , Aged, 80 and over , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Risk Assessment
14.
Ann Vasc Surg ; 103: 31-37, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38301852

ABSTRACT

BACKGROUND: To evaluate the short-term and mid-term safety and efficacy of stent-graft compared with bare stents for treatment of aortoiliac occlusive disease (AIOD). METHODS: One hundred eighty three patients diagnosed with AIOD who received stent implantation at 3 vascular centers in north China between January 2019 and December 2021 were enrolled. Patients were divided into those undergoing stent-graft (Group A; n = 67) or bare stent (Group B; n = 116) implantation for retrospective cohort analysis. Efficacy was assessed as surgical success rate and rate of freedom from clinically driven target lesion reintervention at each follow-up time point. Safety was assessed by the rate of perioperative complication, major limb amputation, and aortoiliac artery-related mortality. RESULTS: There were no preoperative baseline differences between the 2 groups (P > 0.05). The surgical success was 91.04% for Group A, significantly higher than that for Group B (79.31%; P < 0.05). Incidence of perioperative complications was 2.98% for Group A, significantly lower than that for Group B (9.48%, P < 0.05), as was the rate of major limb amputation (A: 1.49% vs. B: 5.17%) and aortoiliac artery-related mortality (A: 1.49% vs. B: 4.31%), although these 2 indicators were not significantly different (P > 0.05). Follow-up rates were 91.8% for the total follow-up time of 3 years. Kaplan-Meier survival curve analysis gave significantly higher 1-year and 2-year freedom from clinically driven target lesion reintervention for Group A (98.51% and 95.52%) than for Group B (95.69% and 89.66%, P < 0.05). CONCLUSIONS: Stent-graft is more effective and safer than bare stent in the treatment of AIOD.


Subject(s)
Amputation, Surgical , Aortic Diseases , Arterial Occlusive Diseases , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endovascular Procedures , Iliac Artery , Stents , Vascular Patency , Humans , Male , Female , Iliac Artery/surgery , Iliac Artery/diagnostic imaging , Retrospective Studies , Middle Aged , Time Factors , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Aged , Aortic Diseases/surgery , Aortic Diseases/diagnostic imaging , Aortic Diseases/mortality , Arterial Occlusive Diseases/surgery , Arterial Occlusive Diseases/diagnostic imaging , Arterial Occlusive Diseases/mortality , China , Treatment Outcome , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Risk Factors , Limb Salvage , Prosthesis Design , Postoperative Complications/etiology , Risk Assessment
15.
Vasc Endovascular Surg ; 58(5): 554-558, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38166566

ABSTRACT

Aortic graft and endograft infections remain a significant source of morbidity and mortality after abdominal aortic aneurysm repair. With graft excision and extra-anatomic bypass, an infrarenal aortic stump remains which can have suture line dehiscence and catastrophic stump blowout. Treatment of this is extremely challenging, especially for severely co-morbid patients who cannot undergo major surgery, or in patients with a hostile abdomen. We present a case study of a 74-year-old male found to have an aortoenteric fistula (AEF). This case broadens operative options for this type of patient population by demonstrating an endovascular technique for addressing aortic stump blowout by parallel grafting and coil embolization of the visceral aorta.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Embolization, Therapeutic , Endovascular Procedures , Intestinal Fistula , Vascular Fistula , Humans , Male , Aged , Embolization, Therapeutic/instrumentation , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Treatment Outcome , Endovascular Procedures/instrumentation , Vascular Fistula/diagnostic imaging , Vascular Fistula/etiology , Vascular Fistula/surgery , Vascular Fistula/therapy , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Intestinal Fistula/diagnostic imaging , Intestinal Fistula/etiology , Intestinal Fistula/surgery , Intestinal Fistula/therapy , Aortography , Computed Tomography Angiography , Aorta, Abdominal/diagnostic imaging , Aorta, Abdominal/surgery
16.
Vasc Endovascular Surg ; 58(5): 505-511, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38258617

ABSTRACT

INTRODUCTION: We sought to examine midterm results and remodeling effect of false-lumen occlusion treatment using AFX VELA in case of chronic dissection repair. MATERIAL AND METHODS: From June 2019 to May 2022, we performed false lumen occlusion treatment using a modified Candy-Plug technique with AFX VELA on 8 chronic aortic dissection patients with a patent false lumen. We collected operative data, short-term clinical outcomes, mid-term clinical outcomes and imaging test results. We conducted follow-up examinations at postoperative, 6-month and 1-, 2- and 3-year intervals, including contrast-enhanced computed tomography to evaluate the diameter, false lumen thrombosis and any events. RESULTS: The average time from the symptom onset to the thoracic endovascular repair was 81.5 (35-155) months. The aorta showed aneurysmal dilation with an average maximum short-axis diameter of 58.9 (41-91) mm. Two cases needed emergency surgery due to rupture and impending rupture. There were no postoperative deaths. Complete thrombosis within the false lumen was achieved in 6 cases (75%), but 2 cases had incomplete thrombosis, requiring additional treatment. The mean maximum diameter showed a significant decrease at 6 months, 1 year and 2 years postoperatively compared to preoperative measurements (P < .05). CONCLUSION: We showed the results of false lumen occlusion treatment using the AFX VELA cuff. We observed favorable clinical outcomes and remodeling effects. While the long-term durability and efficacy of this technique in aortic remodeling will need to be monitored with further observation, the use of this cuff is considered a reliable approach to false lumen occlusion treatment.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endovascular Procedures , Humans , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Aortic Dissection/physiopathology , Male , Middle Aged , Treatment Outcome , Chronic Disease , Aged , Female , Time Factors , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/adverse effects , Retrospective Studies , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/physiopathology , Prosthesis Design , Stents , Vascular Remodeling
17.
Anticancer Res ; 42(3): 1351-1358, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35220227

ABSTRACT

BACKGROUND/AIM: Collecting duct carcinoma, epithelioid angiosarcoma and neuroendocrine/carcinoid tumor are uncommon renal malignancies, and their association with tumor thrombus extending into the inferior vena cava is extremely rare. Owing to the rarity of the above-mentioned malignancies and short follow-up of the cases published in the literature, the prognosis and clinical behavior of these tumors remains unclear. Up to date, the culprit of treatment is surgical management with radical nephrectomy, lymph node dissection, thrombectomy and vascular reconstruction if necessary. PATIENTS AND METHODS: We herein describe in detail the first cases published of the above-mentioned renal malignancies associated with extensive inferior vena cava (IVC) thrombus, in which complex vascular reconstruction was performed. RESULTS: Three male patients were identified as having collecting duct carcinoma, epithelioid angiosarcoma and neuroendocrine/carcinoid tumor with IVC involvement. Tumor thrombus levels were II, I and IIIc respectively. Patient ages were 42, 60 and 47 years and tumor sizes were 9.2, 10.9 and 3.7 cm correspondingly. Patient 2 underwent cavectomy, IVC replacement using polytetrafluoroethylene (Gore-Tex®) vascular graft and IVC filter deployment inside the graft. None of the patients developed any pulmonary emboli postoperatively. At the last follow-up, IVC graft for patient 2 remained patent. CONCLUSION: Owing to the rarity of the aforementioned malignancies and short follow-up of cases published in the literature, the prognosis and clinical behavior of these tumors remains unclear. Up to date, the culprit of treatment is surgical management with radical nephrectomy, lymph node dissection, thrombectomy and vascular reconstruction if necessary. Polytetrafluoroethylene (Gore-Tex) vascular grafts are an excellent and safe option for complex vascular reconstructions in patients with evidence of IVC invasion.


Subject(s)
Blood Vessel Prosthesis Implantation , Carcinoid Tumor/surgery , Carcinoma, Renal Cell/surgery , Hemangiosarcoma/surgery , Kidney Neoplasms/surgery , Nephrectomy , Thrombectomy , Vena Cava, Inferior/surgery , Adult , Blood Vessel Prosthesis Implantation/instrumentation , Carcinoid Tumor/diagnostic imaging , Carcinoid Tumor/pathology , Carcinoma, Renal Cell/diagnostic imaging , Carcinoma, Renal Cell/pathology , Hemangiosarcoma/diagnostic imaging , Hemangiosarcoma/pathology , Humans , Kidney Neoplasms/diagnostic imaging , Kidney Neoplasms/pathology , Male , Middle Aged , Neoplasm Invasiveness , Treatment Outcome , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/pathology
18.
Anticancer Res ; 42(3): 1579-1588, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35220255

ABSTRACT

BACKGROUND/AIM: Management strategies for pseudoaneurysm rupture after pancreatic resection have not yet been firmly established due to its low incidence and effects of environmental variability among centers. This study aimed to provide a basis for treatment strategy improvement. PATIENTS AND METHODS: Clinical features and outcomes of 29 patients who experienced pseudoaneurysm formation or rupture following pancreatic resection were retrospectively reviewed. RESULTS: The incidence of pseudoaneurysm formation was 2.8%. In 28 of 29 patients, pseudoaneurysm was identified via emergent dynamic computed tomography (CT). The rates of complete cessation of bleeding by interventional radiology (IVR) and surgical intervention were 88% and 100%, respectively. Mortality rate was 13.8%. Four patients treated by IVR died, including three of massive bleeding and one of liver failure. CONCLUSION: Patients with suspected pseudoaneurysm rupture after pancreatic resection should undergo immediate CT. Open surgery is preferable for patients with incomplete hemostasis by IVR or those who cannot immediately undergo IVR, however, IVR is an effective alternative.


Subject(s)
Aneurysm, False/therapy , Aneurysm, Ruptured/therapy , Blood Vessel Prosthesis Implantation , Embolization, Therapeutic , Endovascular Procedures , Pancreatectomy/adverse effects , Pancreatic Neoplasms/surgery , Pancreaticoduodenectomy/adverse effects , Adult , Aged , Aged, 80 and over , Aneurysm, False/diagnostic imaging , Aneurysm, False/etiology , Aneurysm, False/mortality , Aneurysm, Ruptured/diagnostic imaging , Aneurysm, Ruptured/etiology , Aneurysm, Ruptured/mortality , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Embolization, Therapeutic/adverse effects , Embolization, Therapeutic/instrumentation , Embolization, Therapeutic/mortality , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Female , Humans , Male , Middle Aged , Radiography, Interventional , Retrospective Studies , Stents , Time Factors , Tokyo , Tomography, X-Ray Computed , Treatment Outcome
19.
J Thorac Cardiovasc Surg ; 163(2): 568-574.e1, 2022 Feb.
Article in English | MEDLINE | ID: mdl-32653283

ABSTRACT

OBJECTIVE: Acute type I aortic dissection (AAD) represents a surgical emergency with time-dependent evolving complications. Frozen elephant trunk (FET) enables false lumen exclusion downstream but is still debated in AAD due to its greater dimension of surgery. To combine the benefits of fast proximal repair with the FET benefits, a 3-zone hybrid graft was developed consisting of an ascending polyester portion, an arch noncovered stent, and a descending stent graft. Mid-term results of this new technique are presented. METHODS: A total of 6 patients (age mean 69 years) with type I AAD in critical status (Penn classification B n = 5, BC n = 1) were operated between July 2016 and April 2018 using the 3-zone hybrid graft. The device was implanted on the basis of strict compassionate use. Operations were performed under distal hypothermic circulatory arrest and selective antegrade cerebral perfusion (SACP). RESULTS: Operative mortality was 17% (n = 1). Mean crossclamp and SACP time were 92 and 34 minutes, respectively, but came down in the last 2 cases to 75/65 crossclamp and 23/24 SACP minutes each. During follow up, mean 19 ± 12 months, one endovascular extension downstream was performed. Imaging control demonstrated no anastomotic-related proximal entry and no true lumen collapse downstream. CONCLUSIONS: The goal to achieve fast and reliable repair of complicated type I AAD down to midthoracic level seems to be achievable. Noncovered stenting of the head vessel's origin does not cause stenosis or obstruction. A multicenter studying of this concept is next.


Subject(s)
Aortic Aneurysm/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Stents , Acute Disease , Adult , Aged , Aortic Dissection/diagnostic imaging , Aortic Dissection/mortality , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/mortality , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Humans , Male , Prosthesis Design , Time Factors , Treatment Outcome
20.
J Thorac Cardiovasc Surg ; 163(2): 539-548.e2, 2022 02.
Article in English | MEDLINE | ID: mdl-32654872

ABSTRACT

OBJECTIVE: Thoracic endovascular aortic repair is the standard of care for acute complicated type B aortic dissections, but long-term single-device outcomes are limited. METHODS: Fifty patients were treated with the Valiant Captivia thoracic stent graft (Medtronic Inc, Santa Rosa, Calif) for acute complicated type B aortic dissections in this prospective, nonrandomized Dissection Trial. All-cause mortality, secondary procedures, and serious adverse events were assessed, and a core lab evaluated images for aortic remodeling. RESULTS: Compliance for both clinical and imaging follow-up was 78% (18 out of 23) for the available patients at 5 years. Notable baseline characteristics were 86% of patients (43 out of 50) had malperfusion, 20% (10 out of 50) had ruptures, and 94% (46 out of 49) had DeBakey class IIIB dissections. The 5-year freedom from dissection-related mortality, secondary procedures related to the dissection, and endoleaks was 83%, 86%, and 85%, respectively. After 5 years, 89% of patients (16 out of 18) had a completely thrombosed false lumen in the stented segment of the aorta and the true lumen diameter over the length of stent graft was stable or increased for 94% of patients (16 out of 17) while the false lumen diameter was stable or decreased in 77% (13 out of 17) after 5 years. CONCLUSIONS: In the Dissection Trial, patients experienced positive and sustained measures of aortic remodeling. Survival outcomes, need for secondary procedures, and adverse event rates were consistent with previous thoracic endovascular aortic repair studies. Although limitations exist with the follow-up compliance, the Valiant Captivia thoracic stent graft system was effective in the long-term management of acute complicated type B aortic dissections in this patient population with a challenging condition.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Acute Disease , Aged , Aortic Dissection/diagnostic imaging , Aortic Dissection/mortality , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/mortality , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Female , Humans , Male , Middle Aged , Postoperative Complications/mortality , Postoperative Complications/surgery , Prospective Studies , Reoperation , Stents , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...