Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27.663
Filter
1.
Eur J Orthod ; 46(3)2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38733349

ABSTRACT

OBJECTIVES: The biomechanics in achieving molar distalization may differ between fixed appliances and clear aligners in the control of tooth movement. The objective of this study was to compare the treatment effects between clear aligners (CA) and fixed appliances (FA) in patients treated with miniscrew-assisted molar distalization. METHODS: The sample consisted of 46 subjects with mild-to-moderate crowding. A total of 22 patients treated with clear aligners (age, 25.66 ±â€…6.11 years old) and 24 patients treated with fixed appliances (age, 24.04 ±â€…4.95 years old) for miniscrew-assisted molar distalization were included in this study. The dental and skeletal changes were evaluated by the pre- and post-treatment lateral cephalograms. RESULTS: Significant changes were found with the vertical variables SN-OP angle (2.24 ±â€…3.22°, P < .05) and SN-MP angle (0.73 ±â€…1.15°, P < .05) for the FA group when compared with the CA group (SN-OP angle 0.41 ±â€…2.26° and SN-MP angle -0.21 ±â€…1.38°, P > .05). Both treatment groups achieved a 2-3 mm. molar distalization with significant intrusion of the upper molars. The CA group showed significantly less distal tipping of molars (U6^PP angle -2.29 ±â€…3.29° and L6^MP angle -2.92 ±â€…2.49°, P < .05) compared to the FA group (-5.24 ±â€…4.28° and -5.53 ±â€…5.03°, P < .05). In addition, significant retraction and lingual inclination of the upper and lower incisors were found in both groups. LIMITATIONS: The changes of tooth position were evaluated by 2D lateral cephalograms, not 3D measurements. CONCLUSIONS: Compared to fixed appliances, clear aligners seemed to have better control of vertical dimension and distal tipping of molars in patients treated with miniscrew-assisted molar distalization.


Subject(s)
Bone Screws , Cephalometry , Molar , Orthodontic Anchorage Procedures , Orthodontic Appliances, Fixed , Tooth Movement Techniques , Humans , Tooth Movement Techniques/instrumentation , Tooth Movement Techniques/methods , Male , Female , Adult , Orthodontic Anchorage Procedures/instrumentation , Orthodontic Anchorage Procedures/methods , Young Adult , Orthodontic Appliance Design , Malocclusion/therapy , Treatment Outcome , Maxilla , Mandible , Orthodontic Appliances, Removable , Incisor , Vertical Dimension
2.
Am J Case Rep ; 25: e943136, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38706183

ABSTRACT

BACKGROUND Hoffa fractures are an uncommon form of coronal fracture that impact the femoral condyle. As a result, they are not very prevalent. It is necessary to perform anatomical reduction and rigorous fixation on these fractures; however, there is no consensus among medical professionals on the surgical procedure and implant that would be the most successful in treating these fractures. CASE REPORT A 50-year-old woman who had poliomyelitis in her right lower limb presented with a displaced medial Hoffa fracture of her left knee. She had fallen and was suffering from poliomyelitis. The trauma that caused this fracture had a modest energy level. Open reduction and internal fixation with 2 retrograde cannulated screws were included in her surgical procedure. An approach known as the medial parapatellar route was used for this treatment. As part of her postoperative rehabilitation, she participated in physiotherapy, exercises that did not require weight bearing, exercises that used passive and active assistance, activities that involved partial and full weight bearing, and exercises that involved complete weight bearing. At the 2-year follow-up, the patient's left knee continued to be painless and stable, and it had unrestricted range of motion across the whole extremity. It was determined via radiographs that the fracture had healed without any problems or arthritic changes developing. She was able to walk without help and carry out her daily tasks since she was able to walk with the use of a cane. CONCLUSIONS Retrograde cannulated screws can be a reliable and successful choice for treatment of medial Hoffa fractures, with positive results according to both clinical and radiographic characteristics. Further research is needed to analyze the outcomes over a longer period of time and make comparisons between this technique and others.


Subject(s)
Femoral Fractures , Fracture Fixation, Internal , Humans , Female , Middle Aged , Fracture Fixation, Internal/methods , Femoral Fractures/surgery , Femoral Fractures/diagnostic imaging , Bone Screws , Open Fracture Reduction , Poliomyelitis/complications , Hoffa Fracture
3.
Trials ; 25(1): 305, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38711052

ABSTRACT

BACKGROUND: To analyze the perioperative bleeding and hidden blood loss (HBL) of sacroiliac screw minimally invasive treatment of pelvic posterior ring injury and explore the influential factors of HBL after operation for providing reference for clinical treatment. METHOD: A retrospective analysis was conducted on data from 369 patients with posterior pelvic ring injuries treated with sacroiliac screws internal fixation at our hospital from January 2015 to January 2022. The research was registered in the Chinese Clinical Trial Registry in July 2022 (ChiCTR2200061866). The total blood loss (TBL) and HBL of patients were counted, and the factors such as gender, age, and surgical duration were statistically analyzed. The influential factors of HBL were analyzed by multiple linear regression. RESULTS: The TBL was 417.96 ± 98.05 ml, of which the visible blood loss (VBL) was 37.00 ± 9.0 ml and the HBL was 380.96 ± 68.8 ml. The HBL accounted for 91.14 ± 7.36% of the TBL. Gender, surgical duration, fixed position, and fixed depth had significant effects on the HBL (P < 0.05). CONCLUSIONS: The HBL was the main cause of anemia after minimally invasive treatment of posterior pelvic ring injury with a sacroiliac screw. Gender, surgical duration, fixed position, and fixed depth were closely related to the occurrence of HBL. In clinical treatment, we should consider these influential factors and take effective measures to reduce the impact of HBL on patients.


Subject(s)
Blood Loss, Surgical , Bone Screws , Fracture Fixation, Internal , Pelvic Bones , Humans , Male , Female , Retrospective Studies , Pelvic Bones/injuries , Pelvic Bones/surgery , Adult , Middle Aged , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Treatment Outcome , Risk Factors , Young Adult , Fractures, Bone/surgery , Fractures, Bone/diagnostic imaging , Time Factors , China , Aged , Minimally Invasive Surgical Procedures/methods , Anemia/etiology
4.
BMC Oral Health ; 24(1): 550, 2024 May 11.
Article in English | MEDLINE | ID: mdl-38734597

ABSTRACT

BACKGROUND: Large cross-arch free-end surgical guides can obscure the visual field, compromising surgical accuracy due to insufficient stability at the free-end. This in vitro study aims to evaluate the accuracy of novel digital non-cross-arch surgical guides designed for implant placement at the mandibular free-end, incorporating tooth undercut retention and screw-bone support. MATERIALS AND METHODS: A mandibular dental model lacking left molars was utilized to fabricate unilateral (cross-arch) tooth-supported surgical guides (GT I, n = 20). Subsequently, two additional types of surgical guides were fabricated: GT II (covering two teeth, n = 20) and GT III (covering three teeth, n = 20). These novel surgical guides were designed to utilize the undercut of the supporting teeth for retention and enhance stability with screw-bone support at the guide's free-end. Furthermore, 60 identical guiding blocks were assembled on the three types of surgical guides to facilitate the implants' insertion. On a phantom head, 120 implant replicas were placed at the Federal Dentaire Internationale (FDI) teeth positions #36 and #37 on the dental model, employing a combination of surgical guides and guiding blocks. To assess accuracy, planned and placed implant positions were compared using intraoral optical scanning. Discrepancies in angulation and linear deviations, including the coronal/apical 3D deviations, lateral deviation as well as depth deviation, were measured. Statistical analysis was performed using two-way ANOVA and Bonferroni test (α = 0.05). RESULTS: GT I exhibited significantly largest discrepancies, including angular and linear deviations at the crest and apex at every implant site. Especially in depth, at implant site #36, the mean deviation value of GT I (0.27 ± 0.13 mm) was twice as large as GT III (0.13 ± 0.07 mm), and almost twice as large as GT II (0.14 ± 0.08 mm). However, at implant site #37, this deviation increased to almost a five-fold relationship between GT I (0.63 ± 0.12 mm) and II (0.14 ± 0.09 mm), as well as between GT I and III (0.13 ± 0.09 mm). No significant discrepancies existed between the novel surgical guides at either implant site #36 or #37. CONCLUSION: This study provides a practical protocol for enhancing accuracy of implant placement and reducing the size of free-end surgical guides used at mandibular molar sites.


Subject(s)
Bone Screws , Mandible , Models, Dental , Surgery, Computer-Assisted , Humans , Mandible/surgery , Surgery, Computer-Assisted/methods , Dental Implantation, Endosseous/methods , Computer-Aided Design , In Vitro Techniques
5.
J Plast Surg Hand Surg ; 59: 46-52, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38747532

ABSTRACT

Standard volar plates often do not fit the surface of the malunited distal radius after osteotomy, necessitating an offset angle for accurate volar tilt correction. The correction can be achieved if the plate is held at the correct angle when the distal screws are locked. With the advantage of 3D surgical planning and patient-specific instruments, we developed a shim instrument to assist the surgeon in securing the plate at the intended angle when locking the distal screws, and evaluated radiological results. Five female patients aged 63-74 with dorsally angulated extra-articular malunions underwent surgery using 3D-printed guides and the shim instrument. The plate position, drilling guide alignment, screw placements, and distal radius correction on postoperative CTs were compared with the surgical plans. Errors were measured using an anatomical coordinate system, and standard 2D radiographic measures were extracted. Preoperative dorsal tilt ranged from 16° to 35°, and postoperative volar tilt from 1° to 11°. 3D analysis revealed mean absolute correction errors of 6.1° in volar tilt, 1.6° in radial inclination, and 0.6 mm in ulnar variance. The volar tilt error due to the shim instrument, indicated by the mean angle error of the distal screws to the plate, was 2.1° but varied across the five patients. Settling of the distal radius, due to tension during and after reduction, further contributed to a mean loss of 3.5° in volar tilt. The shim instrument helped with securing plates at the intended angle; however, further correction improvements should consider the tension between the fragments of osteoporotic bone.


Subject(s)
Bone Plates , Fracture Fixation, Internal , Fractures, Malunited , Osteotomy , Radius Fractures , Humans , Female , Osteotomy/methods , Osteotomy/instrumentation , Middle Aged , Radius Fractures/surgery , Radius Fractures/diagnostic imaging , Aged , Fractures, Malunited/surgery , Fractures, Malunited/diagnostic imaging , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Printing, Three-Dimensional , Surgery, Computer-Assisted , Imaging, Three-Dimensional , Bone Screws , Tomography, X-Ray Computed
6.
J Orthop Surg Res ; 19(1): 290, 2024 May 12.
Article in English | MEDLINE | ID: mdl-38735949

ABSTRACT

BACKGROUND: As an innovative internal fixation system, FNS (femoral neck system) is increasingly being utilized by surgeons for the treatment of femoral neck fractures. At present, there have been numerous finite element analysis experiments studying the immediate stability of FNS and CSS in treating femoral neck fractures. However, there is scarce mechanical analysis available regarding the effects post internal fixation removal. This study aimed to investigate the alterations in mechanical parameters of the proximal femur before and after the removal of FNS (femoral neck system), and to assess potential distinctions in indicators following the extraction of CSS (Cannulated Screws). METHODS: A proximal femur model was reconstructed using finite element numerical techniques. The models for CSS and FNS were formulated utilizing characteristics and parametric definitions. The internal fixation was combined with a normal proximal femur model to simulate the healing state after fracture surgery. Within the framework of static analysis, consistent stress burdens were applied across the entirety of the models. The total deformation and equivalent stress of the proximal femur were recorded before and after the removal of internal fixation. RESULTS: Under the standing condition, the total deformation of the model before and after removing CSS was 0.99 mm and 1.10 mm, respectively, indicating an increase of 12%. The total deformation of the model before and after removing FNS was 0.65 mm and 0.76 mm, respectively, indicating an increase of 17%. The equivalent stress for CSS and FNS were 55.21 MPa and 250.67 MPa, respectively. The average equivalent stress on the cross-section of the femoral neck before and after removal of CSS was 7.76 MPa and 6.11 MPa, respectively. The average equivalent stress on the cross-section of the femoral neck before and after removal of FNS was 9.89 MPa and 8.79 MPa, respectively. CONCLUSIONS: The retention of internal fixation may contribute to improved stability of the proximal femur. However, there still existed risks of stress concentration in internal fixation and stress shielding in the proximal femur. Compared to CSS, the removal of FNS results in larger bone tunnels and insufficient model stability. Further clinical interventions are recommended to address this issue.


Subject(s)
Bone Screws , Femoral Neck Fractures , Finite Element Analysis , Fracture Fixation, Internal , Humans , Biomechanical Phenomena , Femoral Neck Fractures/surgery , Fracture Fixation, Internal/methods , Femur Neck/surgery , Femur Neck/diagnostic imaging , Femur/surgery , Stress, Mechanical , Device Removal/methods
7.
Eur Rev Med Pharmacol Sci ; 28(8): 3165-3175, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38708475

ABSTRACT

OBJECTIVE: Periprosthetic fractures following total knee replacement are rare but challenging. The goal of the treatment is to achieve the most stable fixation that allows early mobilization. Therefore, the aim of this study was to evaluate the biomechanical results of the use of different fixation systems in the treatment of distal femur periprosthetic fractures with finite element analysis. MATERIALS AND METHODS: A total knee prosthesis was implanted in Sawbone femur models. A transverse fracture line was created in the supracondylar region and was fixed in four different groups. In group 1, fracture line fixation was fixed using retrograde intramedullary nailing. In group 2, fixation was applied using a lateral anatomic distal femoral. In group 3, in addition to the fixation made in group 1, a lateral anatomic distal femoral plate was used. In group 4, in addition to the fixation made in group 2, a 3.5 mm Limited Contact Dynamic Compression Plate (LC-DCP) was applied medially. Computed Tomography (CT) scans were taken of the created models and were converted to three-dimensional models. Axial and rotational loading forces were applied to all the created models. RESULTS: The least deformation with axial loading was observed in the double plate group. Group 3 was determined to be more advantageous against rotational forces. The greatest movement in the fracture line was found in group 2. The application of the medial plate was determined to reduce the tension on the lateral plate and increase stability in the fracture line. CONCLUSIONS: Combining a lateral anatomic plate with intramedullary nailing or a medial plate was seen to be biomechanically more advantageous than using a lateral plate or intramedullary nailing alone in the treatment of distal femoral periprosthetic fractures.


Subject(s)
Arthroplasty, Replacement, Knee , Bone Nails , Bone Plates , Femoral Fractures , Finite Element Analysis , Fracture Fixation, Intramedullary , Periprosthetic Fractures , Arthroplasty, Replacement, Knee/adverse effects , Femoral Fractures/surgery , Humans , Periprosthetic Fractures/surgery , Fracture Fixation, Intramedullary/instrumentation , Bone Screws , Biomechanical Phenomena
8.
Eur Rev Med Pharmacol Sci ; 28(8): 3208-3215, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38708479

ABSTRACT

OBJECTIVE: We sought to explore the effectiveness of cannulated screw fixation for femoral neck fractures in middle-aged and elderly patients assisted by a three-dimensional printing navigation template. PATIENTS AND METHODS: A total of 98 middle-aged and elderly patients who underwent cannulated screw fixation for femoral neck fractures were retrospectively analyzed. They were allocated into two groups, each comprising 49 patients. Surgical indexes, hip function, and pain levels were compared between the two groups. RESULTS: The study group, assisted by the three-dimensional printing navigation template, exhibited significantly reduced nail insertion, fewer instances of C-arm fluoroscopy, shorter operation time, quicker time to bone union, earlier initiation of walking exercise, shorter time to weight-bearing walking, and reduced hospital stay than those in the control group (all p<0.001). However, the study group also experienced higher blood loss compared to the control group (p<0.001). Postoperatively, at 3 months and 12 months, the study group demonstrated significantly higher scores compared to the control group (both p<0.001) and reported significantly lower pain scores than that in the other group at 1 week and 12 months post-surgery (both p<0.001). Furthermore, the study group experienced significantly fewer postoperative complications than the control group (p=0.029). CONCLUSIONS: Cannulated screw fixation for femoral neck fractures assisted by a 3D printing navigation template is more effective and safer than traditional fixation methods. This approach represents a promising alternative for surgical management.


Subject(s)
Bone Screws , Femoral Neck Fractures , Fracture Fixation, Internal , Printing, Three-Dimensional , Humans , Femoral Neck Fractures/surgery , Middle Aged , Aged , Female , Male , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Retrospective Studies
9.
J Robot Surg ; 18(1): 204, 2024 May 08.
Article in English | MEDLINE | ID: mdl-38714574

ABSTRACT

Workflow for cortical bone trajectory (CBT) screws includes tapping line-to-line or under tapping by 1 mm. We describe a non-tapping, two-step workflow for CBT screw placement, and compare the safety profile and time savings to the Tap (three-step) workflow. Patients undergoing robotic assisted 1-3 level posterior fusion with CBT screws for degenerative conditions were identified and separated into either a No-Tap or Tap workflow. Number of total screws, screw-related complications, estimated blood loss, operative time, robotic time, and return to the operating room were collected and analyzed. There were 91 cases (458 screws) in the No-Tap and 88 cases (466 screws) in the Tap groups, with no difference in demographics, revision status, ASA grade, approach, number of levels fused or diagnosis between cohorts. Total robotic time was lower in the No-Tap (26.7 min) versus the Tap group (30.3 min, p = 0.053). There was no difference in the number of malpositioned screws identified intraoperatively (10 vs 6, p = 0.427), screws converted to freehand (3 vs 3, p = 0.699), or screws abandoned (3 vs 2, p = 1.000). No pedicle/pars fracture or fixation failure was seen in the No-Tap cohort and one in the Tap cohort (p = 1.00). No patients in either cohort were returned to OR for malpositioned screws. This study showed that the No-Tap screw insertion workflow for robot-assisted CBT reduces robotic time without increasing complications.


Subject(s)
Cortical Bone , Robotic Surgical Procedures , Spinal Fusion , Humans , Robotic Surgical Procedures/methods , Robotic Surgical Procedures/instrumentation , Male , Female , Middle Aged , Cortical Bone/surgery , Aged , Spinal Fusion/methods , Spinal Fusion/instrumentation , Operative Time , Bone Screws , Workflow , Pedicle Screws , Adult
10.
PLoS One ; 19(5): e0302839, 2024.
Article in English | MEDLINE | ID: mdl-38696506

ABSTRACT

PURPOSES: Fractures of the inferior patellar pole, unlike other patellar fractures, present challenges for traditional surgical fixation methods. This article introduces the clinical technique and outcomes of using Kirschner wire tension band combined with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures. METHODS: This retrospective case series study included 14 patients with comminuted inferior patellar pole fractures treated at our institution from September 1, 2020, to April 30, 2022. All patients underwent surgery using the Kirschner wire tension band with anchor screw cross-stitch technique. Follow-up assessments involved postoperative X-rays to evaluate fracture healing, as well as clinical parameters such as healing time, Visual Analog Scale (VAS) scores, range of motion (ROM), and Bostman scores. RESULTS: All patients were followed for an average of over 12 months, with no cases of internal fixation failure. Knee joint stability and function were excellent. X-rays revealed an average healing time of approximately 10.79 ± 1.53 weeks, hospitalization lasted 5.64 ± 1.15 days, surgery took approximately 37.86 ± 5.32 minutes, and intraoperative blood loss was 33.29 ± 8.15 ml. One patient experienced irritation from the internal fixation material. At the final follow-up, the Bostman score averaged 28.29 ± 0.83, knee joint flexion reached 131.07° ± 4.88°, all patients achieved full knee extension, and the VAS score was 0.36 ± 0.63. CONCLUSION: Kirschner wire tension band with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures delivered satisfactory clinical outcomes. This surgical method, characterized by its simplicity and reliability, is a valuable addition to clinical practice.


Subject(s)
Bone Wires , Fracture Fixation, Internal , Fractures, Comminuted , Patella , Humans , Male , Female , Adult , Patella/surgery , Patella/injuries , Fractures, Comminuted/surgery , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Retrospective Studies , Middle Aged , Range of Motion, Articular , Treatment Outcome , Fractures, Bone/surgery , Fracture Healing , Knee Joint/surgery , Knee Joint/physiopathology , Young Adult , Bone Screws , Suture Anchors
11.
J Stomatol Oral Maxillofac Surg ; 125(2): 101667, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38738550

ABSTRACT

OBJECTIVE: To three-dimensionally evaluate post-operative mandibular stability following bilateral sagittal split ramus osteotomies between hybrid and non-hybrid rigid internal fixation techniques. MATERIALS AND METHOD: Seventy adults with skeletal class II deformity who underwent bilateral split sagittal osteotomy with mandibular advancement were included. Patients were divided into four groups based on their fixation techniques: hybrid technique (HT) groups I, II, and IV received a 4-hole 2 mm miniplate with either a bicortical screw (BS), additional 2 mm 4-hole miniplate, or two-hole miniplate, while non-HT group III received a 4-hole 2 mm miniplate with four mini-screws (MS). Measurements were taken pre-operatively (T0), immediately postoperatively (T1), and ≥1 year after surgery (T2) using 3D Slicer software. RESULTS: Age, sex, and follow-up period did not correlate significantly with postoperative relapse or stability. Significant differences were observed in the advancement on the right side between groups II, III, and IV and on the left side between groups I, III, and IV. However, the type of surgical intervention showed no significant effect on postoperative relapse and stability. All groups of fixations showed satisfactory stability with irrelevant relapse (< 2 mm or 2°). CONCLUSION: The study demonstrated satisfactory and comparable stability among different fixation groups on patients undergoing mandibular advancement following bilateral split sagittal osteotomy. The results highlighted the importance of considering the degree of advancement when planning orthognathic surgery and managing postoperative outcomes.


Subject(s)
Imaging, Three-Dimensional , Malocclusion, Angle Class II , Mandibular Advancement , Osteotomy, Sagittal Split Ramus , Humans , Mandibular Advancement/methods , Mandibular Advancement/instrumentation , Osteotomy, Sagittal Split Ramus/methods , Osteotomy, Sagittal Split Ramus/instrumentation , Female , Male , Retrospective Studies , Adult , Malocclusion, Angle Class II/surgery , Bone Plates , Young Adult , Bone Screws , Treatment Outcome , Mandible/surgery , Adolescent
12.
Stomatologiia (Mosk) ; 103(2): 61-70, 2024.
Article in Russian | MEDLINE | ID: mdl-38741537

ABSTRACT

OBJECTIVE: Prevention of the development of pronounced skeletal abnormalities in patients with mesial occlusion. MATERIALS AND METHODS: Biometric analysis of control and diagnostic models of dentition was performed in 60 patients with dental anomalies before and after treatment in 3 mutually perpendicular planes to identify violations in the formation of dental arches by sagittal and transversal dimensions, and alveolar processes - by vertical dimensions (methods of A. Pont, G. Korkhaus). Measurements of 23 parameters of TRG and sections of CBCT were carried out using the modified Nad-Ars technique with analysis of skeletal parameters before and after treatment. Treatment was carried out using dilators for the upper jaw in combination with a facial mask and further dynamic observation using active retention devices. RESULTS: The results of treatment showed an increase in the length of the anterior segment of the upper dental arch by 2.8±0.55 mm (p<0.05 mm); expansion in the area of temporary molars by 2.85±0.65 mm (p<0.05); in the area of permanent molars by 2.75±0.55 mm (p<0.05); in the area of the apical basis of HF by 3.82±0.45 mm (p<0.05). The length of the lower dental arch in the anterior segment has not changed. Analysis of TRG parameters showed a significant increase in the values of

Subject(s)
Dental Arch , Humans , Child , Male , Female , Dental Arch/diagnostic imaging , Malocclusion/therapy , Palatal Expansion Technique/instrumentation , Bone Screws , Dental Occlusion , Orthodontic Anchorage Procedures/instrumentation , Orthodontic Anchorage Procedures/methods , Adolescent , Orthodontic Appliances, Fixed
13.
Sci Rep ; 14(1): 9999, 2024 05 01.
Article in English | MEDLINE | ID: mdl-38693300

ABSTRACT

Although tension band wiring (TBW) is popular and recommended by the AO group, the high rate of complications such as skin irritation and migration of the K-wires cannot be ignored. Ding's screw tension band wiring (DSTBW) is a new TBW technique that has shown positive results in the treatment of other fracture types. The objective of this study was to evaluate the stability of DSTBW in the treatment of olecranon fractures by biomechanical testing. We conducted a Synbone biomechanical model by using three fixation methods: DSTBW, intramedullary screw and tension band wiring (IM-TBW), and K-wire TBW, were simulated to fix the olecranon fractures. We compared the mechanical stability of DSTBW, IM-TBW, and TBW in the Mayo Type IIA olecranon fracture Synbone model using a single cycle loading to failure protocol or pullout force. During biomechanical testing, the average fracture gap measurements were recorded at varying flexion angles in three different groups: TBW, IM-TBW, and DSTBW. The TBW group exhibited measurements of 0.982 mm, 0.380 mm, 0.613 mm, and 1.285 mm at flexion angles of 0°, 30°, 60°, and 90° respectively. The IM-TBW group displayed average fracture gap measurements of 0.953 mm, 0.366 mm, 0.588 mm, and 1.240 mm at each of the corresponding flexion angles. The DSTBW group showed average fracture gap measurements of 0.933 mm, 0.358 mm, 0.543 mm, and 1.106 mm at the same flexion angles. No specimen failed in each group during the cyclic loading phase. Compared with the IM-TBW and TBW groups, the DSTBW group showed significant differences in 60° and 90° flexion angles. The mean maximum failure load was 1229.1 ± 110.0 N in the DSTBW group, 990.3 ± 40.7 N in the IM-TBW group, and 833.1 ± 68.7 N in the TBW group. There was significant difference between each groups (p < 0.001).The average maximum pullout strength for TBW was measured at 57.6 ± 5.1 N, 480.3 ± 39.5 N for IM-TBW, and 1324.0 ± 43.8 N for DSTBW. The difference between maximum pullout strength of both methods was significant to p < 0.0001. DSTBW fixation provides more stability than IM-TBW and TBW fixation models for olecranon fractures.


Subject(s)
Bone Screws , Bone Wires , Fracture Fixation, Internal , Olecranon Process , Humans , Olecranon Process/injuries , Olecranon Process/surgery , Biomechanical Phenomena , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Ulna Fractures/surgery , Ulna Fractures/physiopathology , Fractures, Bone/surgery , Olecranon Fracture
14.
BMC Musculoskelet Disord ; 25(1): 286, 2024 Apr 13.
Article in English | MEDLINE | ID: mdl-38614975

ABSTRACT

OBJECTIVE: Femoral neck fractures (FNFs) are among the most common fractures in elderly individuals. Surgery is the main treatment for FNFs, and osteonecrosis of the femoral head (ONFH) is one of the unacceptable complications. This study aimed to assess both the clinical and radiological outcomes in patients with FNFs treated with three parallel cannulated screws and to identify relationship between screws position and ONFH. PATIENTS AND METHODS: A total of 100 patients who were treated with closed reduction and fixed with 3 parallel cannulated screws met the inclusion criteria between January 2014 and December 2020 at authors' institution. The follow-up duration, age, sex, affected side, and injury-to-surgery interval were collected; the neck-shaft angle of both hips, screw-apex distance (SAD) and the tip-apex distance (TAD)were measured; and the Garden classification, quality of reduction and presence of ONFH were evaluated. RESULTS: The sample consisted of 37 males and 63 females, with 60 left and 40 right hips affected. The mean age of patients was 54.93 ± 12.24 years, and the mean follow-up was 56.3 ± 13.38 months. The overall incidence of ONFH was 13%. No significant difference was observed in the incidence of ONFH by affected side, age, fracture displacement, injury-to-surgery interval, neck-shaft angle deviation, or reduction quality. The SAD was significantly shorter in ONFH patients than in normal patients for all three screws (p = 0.02, 0.02, and 0.01, respectively). CONCLUSIONS: The short SAD of all screws is associated with femoral head necrosis of FNFs treated with 3 cannulated screws. The short SAD indicated that screws malpositioning in the weight-bearing area of the femoral head, potentially harming the blood supply and compromising the anchorage of the primary compressive trabeculae in this region.


Subject(s)
Femoral Neck Fractures , Fenofibrate , Osteonecrosis , Adult , Aged , Female , Male , Humans , Middle Aged , Femur Head/diagnostic imaging , Femur Head/surgery , Femoral Neck Fractures/diagnostic imaging , Femoral Neck Fractures/surgery , Necrosis , Bone Screws/adverse effects
15.
Dent Med Probl ; 61(2): 257-268, 2024.
Article in English | MEDLINE | ID: mdl-38686968

ABSTRACT

BACKGROUND: The screw-retrievable cement-retained (SRCR) design combines the benefits of both screwand cement-retained implant-supported restorations. This concept has sparked interest in implant dentistry. However, there is a lack of research on fracture behaviors and clinical performance of such restorations. OBJECTIVES: The aim of the present article was to review the current literature on the fracture loads and fracture modes of SRCR implant restorations - in vitro studies, and also studies demonstrating the clinical performance of such design. MATERIAL AND METHODS: A literature search was conducted from January 2000 to June 2022, using 6 databases to identify studies on fracture load and clinical performance that fulfilled the eligibility criteria. Thirty-eight studies met the inclusion criteria (22 in vitro and16 in vivo). The in vivo studies comprised case reports/series/letters (9), clinical techniques (2), retrospective/prospective studies (3), and randomized controlled trials (RCTs) (2). RESULTS: The reviewed articles reported the effects of the SRCR design on the fracture risk if screw access channels were filled or unfilled, with regard to their diameter, and the preparation before or after glazing. The effect of the type of material used in the construction on the fracture modes SRCR restorations was also reported. The long-term clinical data was mainly retrospective and referred to metal-ceramic constructions. Limited long-term clinical data was available for all-ceramic materials and high-performance polymers (HPPs). CONCLUSIONS: Screw-retrievable cement-retained implant restorations appear to have potential in the monolithic design. If the SRCR construction is metal-ceramic or made of a veneered material, special design and abutment selection should be considered. High-performance polymers may be recommended as a substitute for posterior implant restoration.


Subject(s)
Dental Cements , Dental Prosthesis, Implant-Supported , Dental Restoration Failure , Humans , Dental Implants , Dental Stress Analysis , Bone Screws
16.
Int J Biol Macromol ; 267(Pt 2): 131519, 2024 May.
Article in English | MEDLINE | ID: mdl-38608985

ABSTRACT

Hydrogel has attracted tremendous attentions due to its excellent biocompatibility and adaptability in biomedical field. However, it is challenging by the conflicts between inadequate mechanical properties and service requirements. Herein, a rapid and robust hydrogel was developed by interpenetrating networks between chitosan and silk fibroin macromolecules. Thanks to these unique networks, the chitosan-based hydrogel exhibited superior mechanical performances. The maximum breaking strength, Young's modulus and swelling ratio of the hydrogel were 1187.8 kPa, 383.1 MPa and 4.5 % respectively. The hydrogel also supported the proliferation of human umbilical vein endothelial cells for 7 days. Notably, the hydrogel was easily molded into bone screw, and demonstrated compressive strengths of 45.7 MPa, Young's modulus of 675.6 MPa, respectively. After 49-day biodegradation, the residual rate of the screw in collagenase I solution was up to 89.6 % of the initial weight. In vitro, the screws not only had high resistance to biodegradation, but also had outstanding biocompatibility of osteoblast. This study provided a promising physical-chemical double crosslinking strategy to build orthopedic materials, holding a great potential in biomedical devices.


Subject(s)
Biocompatible Materials , Bone Screws , Chitosan , Fibroins , Human Umbilical Vein Endothelial Cells , Materials Testing , Chitosan/chemistry , Chitosan/pharmacology , Fibroins/chemistry , Humans , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology , Human Umbilical Vein Endothelial Cells/drug effects , Hydrogels/chemistry , Cell Proliferation/drug effects , Osteoblasts/drug effects , Osteoblasts/cytology , Compressive Strength , Elastic Modulus
17.
Arch Orthop Trauma Surg ; 144(5): 2157-2163, 2024 May.
Article in English | MEDLINE | ID: mdl-38613611

ABSTRACT

INTRODUCTION: The standard surgical procedure for unstable ankle fractures is fixation of the lateral malleolus with a plate and screws. This method has a high risk of complications, especially among patients with fragile skin conditions. The aim of this study was to estimate the re-operation rates and identify complications in patients with an unstable ankle fracture, surgically treated with an intramedullary screw or rush pin. MATERIALS AND METHODS: We identified all patients who were surgically treated with either a 3.5-mm screw or rush pin at Aarhus University Hospital, Denmark, from 2012 to 2018. Major complications were re-operations within three months. We included 80 patients, of which 55 (69%) were treated with a 3.5-mm intramedullary screw and 25 (31%) with a rush pin. The majority of the study population was female (59) and the mean age was 75 (range 24 to 100) years. Of the 80 patients included, 41 patients had more than 2 comorbidities. RESULTS: Three patients underwent re-operation within three months due to either fracture displacement or hardware cutout. Radiographs obtained after six weeks showed that nine patients had loss of reduction. Additionally, four patients had superficial wound infections and six patients had delayed wound healing. CONCLUSIONS: Intramedullary fixation of distal fibula fractures with either a screw or rush pin has low re-operation rates. However, the high proportion of patients with radiological loss of reduction is concerning.


Subject(s)
Ankle Fractures , Bone Nails , Bone Screws , Fracture Fixation, Intramedullary , Reoperation , Humans , Female , Ankle Fractures/surgery , Male , Retrospective Studies , Middle Aged , Adult , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Aged , Aged, 80 and over , Reoperation/statistics & numerical data , Young Adult , Postoperative Complications/epidemiology
18.
J Orthop Surg Res ; 19(1): 237, 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38610006

ABSTRACT

BACKGROUND: Locking plates are commonly used for the fixation of comminuted, periprosthetic and osteoporotic bone fractures. These plates are secured to the bone with screws, creating a stable connection with fixed angle between the plate and the screws. In this biomechanical in vitro study, our aim is to evaluate and compare the novel locking plate-locking spongious screw model with FDA approved classical locking plate. METHODS: Sawbone PCF-15 osteoporotic bone model was utilized to simulate osteoporotic bone conditions. Two screws were used to attach both the classical locking plate and the novel locking plate-locking spongious screw model to these bone models. The attachment strength of the screws to the bone blocks was measured by pull-out tests. RESULTS: Novel locking plate-locking spongious screw model exhibited an 84.38% stronger attachment to the osteoporotic bone model compared to the current locking plate model. CONCLUSIONS: In conclusion, one of the important problems in the locking plates which is the high Pull-out risk of the locking spongious screws can been resolved with our proposed new model and has a chance of having a better purchase especially in osteoporotic bones.


Subject(s)
Bone Diseases , Osteoporosis , Humans , Research Design , Bone Plates , Bone Screws
19.
Zhongguo Gu Shang ; 37(4): 399-405, 2024 Apr 25.
Article in Chinese | MEDLINE | ID: mdl-38664212

ABSTRACT

OBJECTIVE: To compare screw versus Kirschner wire fixation in the treatment of lateral humeral condyle fractures in children. METHODS: A systematic search was conducted in PubMed, Embase, the Cochrane library, Web of Science, China National Knowledge Internet(CNKI), Wanfang Datebase from in ception to February 2022. Studies comparing screws and Kirschner wire fixation in the treatment of lateral humeral condyle fractures in children were included. Outcome measures included and excluded by a set of inclusion and exclusion criteria and evaluated for their quality, their excellent and good rate of fracture healing, malunion, delayed union or nonunion, infection, limitation of elbow flexion or extension(>10°) were extracted and analyzed using software Rev Man 5.3. RESULTS: A total of 9 retrospective studies involving 647 patients were included, with 255 patients in the screw fixation group(including screw combined with Kirschner wire) and 392 patients in the Kirschner wire fixation group. Meta analysis showed the following:infection rate in the screw group was significantly lower than that in the Kirschner wire group[OR=0.22, 95%CI(0.09, 0.56), P=0.001]. There were no significant differences between the 2 groups in excellent and good rate of fracture healing, malunion rate(P>0.05). Subgroup analysis showed that infection rate in the screw-only group was significantly lower than that in the Kirschner wire group[OR=0.18, 95%CI(0.05, 0.65), P=0.009]. CONCLUSION: For lateral humeral condyle fractures, Screw fixation alone had a lower infection rate than kirschner wire fixation and screw combined with Kirschner wire fixation. There were no significant differences in the excellent and good rate of fracture healing, malunion. In terms of postoperative efficacy and safety of internal fixation, orthopaedic surgeons are more likely to recommend screws for fixation of lateral humeral condyle fractures in children.


Subject(s)
Bone Screws , Bone Wires , Fracture Fixation, Internal , Humeral Fractures , Humans , Fracture Fixation, Internal/methods , Child , Humeral Fractures/surgery , Humeral Fractures, Distal
20.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 55(2): 303-308, 2024 Mar 20.
Article in Chinese | MEDLINE | ID: mdl-38645868

ABSTRACT

Objective: To compare the clinical effects of cortical bone trajectory screws and traditional pedicle screws in posterior lumbar fusion. Methods: A retrospective study was conducted to analyze lumbar degeneration patients who underwent surgical treatment at our hospital between January 2016 and January 2019. A total of 123 patients who met the inclusion criteria were enrolled. The subjects were divided into two groups according to their surgical procedures and the members of the two groups were matched by age, sex, and the number of fusion segments. There were 63 patients in the traditional pedicle screws (PS) group and 60 in the cortical bone trajectory screws (CBTS) group. The outcomes of the two groups were compared. The primary outcome measures were perioperative conditions, including operation duration, estimated intraoperative blood loss (EBL), and length-of-stay (LOS), visual analog scale (VAS) score, Oswestry Disability Index (ODI) score, and interbody fusion rate. The secondary outcome measures were the time to postoperative ambulation and the incidence of complications. VAS scores and ODI scores were assessed before operation, 1 week, 1 month, 3 months, and 12 months after operation, and at the final follow-up. The interbody fusion rate was assessed in 1 year and 2 years after the operation and at the final follow-up. Results: The CBTS group showed a reduction in operation duration ([142.8±13.1] min vs. [174.7±15.4] min, P<0.001), LOS ([9.5±1.5] d vs. [12.0±2.0] d, P<0.001), and EBL ([194.2±38.3] mL vs. [377.5±33.1] mL, P<0.001) in comparison with the PS group. The VAS score for back pain in the CBTS group was lower than that in the PS group at 1 week and 1 month after operation and the ODI score in the CBTS group was lower than that in the PS group at 1 month after operation, with the differences being statistically significant (P<0.05). At each postoperative time point, the VAS score for leg pain and the interbody fusion rate did not show significant difference between the two groups. The VAS score for back and leg pain and the ODI score at each time point after operation in both the CBTS group and the PS group were significantly lower than those before operation (P<0.05). No significant difference was found in the time to postoperative ambulation or the overall complication incidence between the two groups. Conclusion: The CBTS technique could significantly shorten the operation duration and LOS, reduce EBL, and achieve the same effect as the PS technique does in terms of intervertebral fusion rate, pain relief, functional improvement, and complication incidence in patients undergoing posterior lumbar fusion.


Subject(s)
Cortical Bone , Lumbar Vertebrae , Pedicle Screws , Spinal Fusion , Humans , Spinal Fusion/methods , Spinal Fusion/instrumentation , Lumbar Vertebrae/surgery , Retrospective Studies , Male , Female , Cortical Bone/surgery , Operative Time , Length of Stay , Middle Aged , Treatment Outcome , Intervertebral Disc Degeneration/surgery , Bone Screws , Blood Loss, Surgical/statistics & numerical data
SELECTION OF CITATIONS
SEARCH DETAIL
...