1.
J Cardiovasc Electrophysiol ; 33(6): 1244-1254, 2022 06.
Article in English | MEDLINE | ID: mdl-35419908

ABSTRACT

INTRODUCTION: Left bundle branch area pacing (LBBAP) is a novel physiological pacing modality. The relationship between the pacing lead tip location and paced electrocardiographic (ECG) characteristics remains unclear. The objectives are to determine the lead tip location within the interventricular septum (IVS) and assess the location-based ECG QRS duration (QRSd) and left ventricular activation time (LVAT). METHODS: This multicenter study enrolled 50 consecutive bradycardia patients who met pacemaker therapy guidelines and received LBBAP implantation via the trans-ventricular septal approach. After at least 3 months postimplant, 12-lead ECGs and pacing parameters were obtained. Cardiac computed tomography (CT) imaging was performed to assess the LBBAP lead tip distance from the LV blood pool. RESULTS: Among the 50 patients, analyzable CT images were obtained in 42. In 23 of the 42 patients, the lead tips were within 2 mm to the LV blood pool (the LV subendocardial (LVSE) group), 13 between 2 and 4 mm (the Near-LVSE group), and the remaining 6 beyond 4 mm (the Mid-LV septal (Mid-LVS) group). No significant differences in paced QRSd were found among the three groups (LVSE, 107 ± 15 ms; Near-LVSE, 106 ± 13 ms; Mid-LVS, 104 ± 15 ms; p = .87). LVAT in the LVSE (64 ± 7 ms) was significantly shorter than in the Mid-LVS (72 ± 8 ms; p < .05), but not significantly different from that in the Near-LVSE (69 ± 8 ms; p > .05). CONCLUSION: In routine LBBAP practice, paced narrow QRSd and fast LVAT, indicative of physiological pacing, were consistently achieved for lead tip location in the LV subendocardial or near LV subendocardial region.


Subject(s)
Bradycardia , Cardiac Pacing, Artificial , Bradycardia/diagnostic imaging , Bradycardia/therapy , Cardiac Pacing, Artificial/methods , Electrocardiography/methods , Heart Conduction System , Humans , Tomography, X-Ray Computed
2.
J Interv Card Electrophysiol ; 63(1): 175-183, 2022 Jan.
Article in English | MEDLINE | ID: mdl-33616880

ABSTRACT

PURPOSE: We aimed to evaluate the electrical characteristics and pacing parameters at different locations of His-Purkinje system pacing. METHODS: Patients who successfully underwent His-Purkinje system pacing with bradycardia indications from April 2018 to August 2019 were retrospectively analyzed according to the lead location confirmed by visualization of the tricuspid value annulus, postoperative echocardiography, and pacing electrocardiogram. The electrical characteristics and pacing parameters were compared among these patients. RESULTS: A total of 135 patients were retrospectively analyzed. Among them, 30 patients received atrial side HBP (aHBP group), 52 received ventricular side HBP (vHBP group), and 53 received left bundle branch pacing (LBBP group). The proportion of non-selective pacing was significantly lower in aHBP group (30.0%) than in vHBP (75.0%) and LBBP group (90.6%). LBBP had significantly shorter procedural and fluoroscopic duration than aHBP and vHBP. The capture threshold was significantly higher (1.07 ± 0.26 V/1.0 ms vs. 0.89 ± 0.22 V/1.0 ms vs. 0.77 ± 0.18 V/0.4 ms, P < 0.01, respectively), and the R-wave amplitude was significantly lower (3.71 ± 1.72 mV vs. 5.81 ± 2.37 mV vs. 10.27 ± 4.71 mV, P < 0.05 respectively) in aHBP group than those in the other two groups at implantation and during 3-month follow-up. No significant differences were observed in complications among groups during 3-month follow-up. CONCLUSION: VHBP and LBBP had better pacing performances than aHBP and might be more ideal pacing methods for bradycardia patients.


Subject(s)
Bradycardia , Bundle of His , Bradycardia/diagnostic imaging , Bradycardia/therapy , Bundle of His/diagnostic imaging , Cardiac Pacing, Artificial , Electrocardiography , Heart Conduction System , Humans , Retrospective Studies , Treatment Outcome
4.
J Interv Card Electrophysiol ; 60(2): 239-245, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32242303

ABSTRACT

BACKGROUND: Leadless pacemakers are an effective treatment for bradycardia. However, some cases exhibit pericardial effusions, presumably associated with device implantations on the right ventricular free-wall. The present study was carried out to find the ECG features during ventricular pacing with a Micra, which enabled distinguishing free-wall implantations from septal implantations without using imaging modalities. METHODS: Thirty-one consecutive patients who received Micra implantations in our facility were enrolled. The location of the device in the right ventricle was evaluated using echocardiography or computed tomography in order to determine whether the device was implanted on the septum (Sep group), apex (Apex group), or free-wall (FW group). The differences in the 12-lead ECG during ventricular pacing by the Micra were analyzed between the Sep and FW groups. RESULTS: The body of the Micra was clearly identifiable in 22 patients. The location of the device was classified into Sep in 12 patients, Apex in 4, and FW in 6. The mean age was highest in the FW and lowest in the Sep group (82.7 ± 6.6 vs. 72.8 ± 8.7 years, p = 0.027). The peak deflection index (PDI) was significantly larger in the FW group than Sep/Apex group in lead V1 (Sep: 0.505 ± 0.010, Apex: 0.402 ± 0.052, FW: 0.617 ± 0.043, p = 0.004) and lead V2 (Sep: 0.450 ± 0.066, Apex: 0.409 ± 0.037, FW: 0.521 ± 0.030, p = 0.011), whereas there was no difference in the QRS duration, transitional zone, and QRS notching. CONCLUSION: The PDI in V1 could be useful for predicting implantations of Micra devices on the free-wall and may potentially stratify the risk of postprocedural pericardial effusions.


Subject(s)
Pacemaker, Artificial , Bradycardia/diagnostic imaging , Bradycardia/therapy , Cardiac Pacing, Artificial , Echocardiography , Electrocardiography , Heart Ventricles/diagnostic imaging , Humans
6.
Sci Rep ; 10(1): 11831, 2020 07 16.
Article in English | MEDLINE | ID: mdl-32678143

ABSTRACT

A meta-analysis of genome-wide association studies (GWAS) identified eight loci that are associated with heart rate variability (HRV), but candidate genes in these loci remain uncharacterized. We developed an image- and CRISPR/Cas9-based pipeline to systematically characterize candidate genes for HRV in live zebrafish embryos. Nine zebrafish orthologues of six human candidate genes were targeted simultaneously in eggs from fish that transgenically express GFP on smooth muscle cells (Tg[acta2:GFP]), to visualize the beating heart. An automated analysis of repeated 30 s recordings of beating atria in 381 live, intact zebrafish embryos at 2 and 5 days post-fertilization highlighted genes that influence HRV (hcn4 and si:dkey-65j6.2 [KIAA1755]); heart rate (rgs6 and hcn4); and the risk of sinoatrial pauses and arrests (hcn4). Exposure to 10 or 25 µM ivabradine-an open channel blocker of HCNs-for 24 h resulted in a dose-dependent higher HRV and lower heart rate at 5 days post-fertilization. Hence, our screen confirmed the role of established genes for heart rate and rhythm (RGS6 and HCN4); showed that ivabradine reduces heart rate and increases HRV in zebrafish embryos, as it does in humans; and highlighted a novel gene that plays a role in HRV (KIAA1755).


Subject(s)
Bradycardia/genetics , Heart Rate/physiology , Hyperpolarization-Activated Cyclic Nucleotide-Gated Channels/genetics , Myocardial Contraction/physiology , RGS Proteins/genetics , Animals , Animals, Genetically Modified , Bradycardia/diagnostic imaging , Bradycardia/metabolism , Bradycardia/physiopathology , CRISPR-Cas Systems , Cardiovascular Agents/pharmacology , Embryo, Nonmammalian , Genes, Reporter , Genome-Wide Association Study , Green Fluorescent Proteins/genetics , Green Fluorescent Proteins/metabolism , Heart Rate/drug effects , Humans , Hyperpolarization-Activated Cyclic Nucleotide-Gated Channels/antagonists & inhibitors , Hyperpolarization-Activated Cyclic Nucleotide-Gated Channels/metabolism , Ivabradine/pharmacology , Meta-Analysis as Topic , Myocardial Contraction/drug effects , Myocytes, Smooth Muscle/cytology , Myocytes, Smooth Muscle/drug effects , Myocytes, Smooth Muscle/metabolism , Optical Imaging/methods , Pleckstrin Homology Domains/genetics , RGS Proteins/metabolism , Zebrafish
7.
Pharmacogenomics ; 21(6): 387-392, 2020 04.
Article in English | MEDLINE | ID: mdl-32284009

ABSTRACT

Subarachnoid hemorrhage is a devastating form of stroke with often detrimental outcomes for patients. Here we describe a patient with subarachnoid hemorrhage treated with nimodipine, which resulted in marked bradycardia with junctional atrioventricular heart block. Nimodipine is metabolized predominantly by the cytochrome P450 3A subfamily, and its use is often associated with adverse events, such as hypotension and bradycardia, which can be exacerbated by advanced age. Our patient had the CYP3A5*3/*3 genotype, possibly predisposing her to poor metabolism of this drug. Our case report demonstrates the potential for pharmacogenomics in patients with subarachnoid hemorrhage to help predict their response to nimodipine, minimize adverse drug reactions, and potentially individualize dosing to improve future clinical outcomes.


Subject(s)
Antihypertensive Agents/adverse effects , Bradycardia/chemically induced , Nimodipine/adverse effects , Subarachnoid Hemorrhage/chemically induced , Aged, 80 and over , Bradycardia/diagnostic imaging , Bradycardia/genetics , Cytochrome P-450 CYP3A/genetics , Female , Humans , Subarachnoid Hemorrhage/diagnostic imaging , Subarachnoid Hemorrhage/genetics
8.
Am J Obstet Gynecol ; 223(2): 242.e1-242.e22, 2020 08.
Article in English | MEDLINE | ID: mdl-32109464

ABSTRACT

BACKGROUND: Pregnancy loss prediction based on routinely measured ultrasound characteristics is generally aimed toward distinguishing nonviability. Physicians also use ultrasound indicators for patient counseling, and in some cases to decide upon the frequency of follow-up sonograms. To improve clinical utility, allocation of cut-points should be based on clinical data for multiple sonographic characteristics, be specific to gestational week, and be determined by methods that optimize prediction. OBJECTIVES: To identify routinely measured features of the early first trimester ultrasound and the gestational age-specific cut-points that are most predictive of pregnancy loss. MATERIALS AND METHODS: This was a secondary analysis of 617 pregnant women enrolled in the Effects of Aspirin in Gestation and Reproduction (EAGeR) trial; all women had 1-2 previous pregnancy losses and no documented infertility. Each participant had a single ultrasound with a detectable fetal heartbeat between 6 weeks 0 days and 8 weeks 6 days. Cut-points for low fetal heart rate and small crown-rump length were separately defined for gestational weeks 6, 7, and 8 to optimize prediction. Identity and log-binomial regression models were used to estimate absolute and relative risks, respectively, and 95% confidence intervals between jointly categorized low fetal heart rate, small crown-rump length, and clinical pregnancy loss. Adjusted models accounted for gestational age at ultrasound in weeks. Missing data were addressed using multiple imputation. RESULTS: A total of 64 women experienced a clinical pregnancy loss following the first ultrasound (10.4%), 7 were lost to follow-up (1.1%), and 546 women (88.5%) had a live birth. Low fetal heart rate and small crown-rump length (≤122, 123, and 158 bpm; ≤6.0, 8.5, and 10.9 mm for gestational weeks 6, 7, and 8, respectively) were independent predictors of clinical pregnancy loss, with greatest risks observed for pregnancies having both characteristics (relative risk, 2.08; 95% confidence interval, 1.24-2.91). The combination of low fetal heart rate and small crown-rump length was linked to a 16% (95% confidence interval, 9.1-23%) adjusted absolute increase in risk of subsequent loss, from 5.0% (95% confidence interval, 1.5-8.5%) to 21% (95% confidence interval, 15-27%). Abnormal yolk sac diameter or the presence of a subchorionic hemmhorage did not improve prediction of clinical pregnancy loss. CONCLUSION: Identified cut-points can be used by physicians for patient counseling, and in some cases to decide upon the frequency of follow-up sonograms. The specified criteria should not be used to diagnose nonviability.


Subject(s)
Abortion, Spontaneous/epidemiology , Bradycardia/epidemiology , Crown-Rump Length , Fetal Growth Retardation/epidemiology , Heart Rate, Fetal , Pregnancy Trimester, First , Ultrasonography, Prenatal , Adult , Bradycardia/diagnostic imaging , Chorion/diagnostic imaging , Clinical Decision Rules , Female , Fetal Growth Retardation/diagnostic imaging , Gestational Age , Humans , Pregnancy , Risk Assessment , Yolk Sac/diagnostic imaging , Young Adult
9.
Magn Reson Med Sci ; 19(4): 345-350, 2020 Dec 01.
Article in English | MEDLINE | ID: mdl-31956176

ABSTRACT

PURPOSE: Modified Look-Locker inversion recovery (MOLLI) using a 5s(3s)3s scheme is robust to tachycardia, but some errors are occasionally observed in myocardial T1 mapping. We sought to evaluate the relationship between measurement errors in T1 mapping and heart rate (HR) using a confidence map. METHODS: We enrolled 69 male patients with normal native T1 values of the septal myocardium measured by a 5s(3s)3s MOLLI. The degree of measurement errors in the septal myocardium was assessed by two independent observers on a confidence map using a 4-point scale: 0, no errors; 1, errors located on the myocardial contour; 2, errors extended into the myocardial contour; and 3, errors extended into the midwall. We compared the scores of measurement errors and the average, maximum, minimum or variability of the HR indicated during the MOLLI scan (iHR), image phases of MOLLI or left ventricular ejection fraction (LVEF). RESULTS: Patients with score >1 for the septal myocardium had significantly lower minimum iHR than those with a score ≤1 (P < 0.01; 49.8 ± 10.1 vs. 59.6 ± 9.7 beat per min). CONCLUSION: The confidence map shows more measurement errors in patients with lower minimum iHR. The myocardial T1 values should be measured carefully in patients with bradycardia during MOLLI scanning.


Subject(s)
Heart Rate , Heart/diagnostic imaging , Magnetic Resonance Imaging , Myocardium/pathology , Stroke Volume , Ventricular Function, Left , Adult , Bradycardia/diagnostic imaging , Diagnostic Errors , Heart Septum/diagnostic imaging , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Predictive Value of Tests , Reproducibility of Results
10.
Eur J Sport Sci ; 20(7): 920-925, 2020 Aug.
Article in English | MEDLINE | ID: mdl-31550203

ABSTRACT

Using electrocardiography and echocardiography, we screened elite men and women ballet dancers for abnormal cardiovascular conditions using an observation design with blinded clinical analysis of cardiac function tests. Fifty-eight (females n = 33) elite professional ballet dancers (age: 26.0 ± 5.7 years, body mass index: 19.9 ± 2.2 kg/m2) with no past or present history of cardiovascular disease volunteered. Participants were assessed via a 12-lead electrocardiography and two-dimensional echocardiography for cardiac function. Electrocardiography revealed that 83% of the dancers demonstrated normal axis, while 31% had incomplete right bundle branch block and 17% had sinus bradycardia; none showed any abnormal findings. Findings from the echocardiography were also normal for all participants and comparable to their counterparts in other sports. Significant differences (p < 0.05) were detected in almost all studied echocardiographic parameters between males and females. In conclusion, heart function and structure seem to be normal in elite ballet dancers, placing them at low risk for sudden cardiac death and performance-related cardiovascular complications. Larger samples are required to confirm these findings.


Subject(s)
Bradycardia/diagnostic imaging , Bundle-Branch Block/diagnostic imaging , Dancing/physiology , Heart Function Tests , Hypertrophy, Left Ventricular/diagnostic imaging , Adult , Body Mass Index , Echocardiography/methods , Electrocardiography/methods , Female , Humans , Male , Sex Factors
12.
Int Heart J ; 60(5): 1222-1225, 2019 Sep 27.
Article in English | MEDLINE | ID: mdl-31484879

ABSTRACT

Bradycardia is a common complication at the early postoperative period after heart transplantation (HT). The heart rate (HR) usually recovers within a few weeks; however, several patients need a temporary pacemaker or chronotropic agents to stabilize their hemodynamics. Here, we report the first case of transient bradycardia associated with hemodynamic deterioration following HT, which was successfully treated with cilostazol, a phosphodiesterase-3-inhibiting agent. A 59-year-old man received HT for advanced heart failure due to ischemic cardiomyopathy. General fatigue persisted even after the HT. His HR was around 60 beats per minute (bpm) with sinus rhythm. Echocardiography showed no abnormal findings. Right heart catheterization showed that the cardiac index (CI) was 1.9 L/minute/m2. Continuous intravenous infusion of isoproterenol (0.003 µg/kg/minute) increased the HR to 80 bpm and CI to 2.7 L/minute/m2 and improved his symptoms. Isoproterenol was switched to oral administration of cilostazol (100 mg, twice a day), which maintained the HR at around 80 bpm and CI of 2.5 L/minute/m2. The patient's HR gradually recovered and cilostazol could be discontinued three months after the HT. Oral administration of cilostazol can be a therapeutic option for patients with sinus bradycardia following HT, who need positive chronotropic support.


Subject(s)
Bradycardia/drug therapy , Cilostazol/therapeutic use , Heart Failure/surgery , Heart Transplantation/adverse effects , Bradycardia/diagnostic imaging , Bradycardia/etiology , Cardiac Output/drug effects , Electrocardiography/methods , Follow-Up Studies , Heart Failure/diagnosis , Heart Transplantation/methods , Hemodynamics/drug effects , Humans , Male , Middle Aged , Postoperative Complications/diagnosis , Postoperative Complications/drug therapy , Pulmonary Edema/diagnostic imaging , Pulmonary Edema/etiology , Pulmonary Edema/physiopathology , Radiography, Thoracic/methods , Time Factors , Treatment Outcome
13.
Tohoku J Exp Med ; 248(4): 307-311, 2019 08.
Article in English | MEDLINE | ID: mdl-31462599

ABSTRACT

Hypothyroidism is rarely included in the differential diagnosis for fetal sinus bradycardia. We report an infant with congenital hypothyroidism caused by ectopic thyroid tissue, who showed antenatal bradycardia. The baseline fetal heart rate was 100-110 bpm at 30 weeks of gestation, and fetal echocardiography revealed sinus bradycardia but no cardiac anomalies. Maternal thyroid function was normal (thyroid-stimulating hormone [TSH] 2.03 µIU/ml, free T3 2.65 pg/ml, and free T4 0.99 ng/dl) when measured at 31 weeks of gestation. Her serum anti SS-A and SS-B antibodies, anti-thyroglobulin, and microsomal antibodies were negative. A male infant without cardiac anomalies was delivered at 35 weeks and 4 days of gestation and admitted for prematurity and respiratory distress syndrome. The infant's heart rate was 70-110 bpm (normal: 120-160 bpm) on admission. On 8 days of age, thyroid function tests revealed that the infant had severe hypothyroidism (TSH 903.3 µIU/ml, free T3 1.05 pg/ml, and free T4 0.26 ng/dl). The prolonged jaundice assumed to be due to hypothyroidism. Oral levothyroxine sodium hydrate (10 µg/kg/day) was immediately started on day 8. After the treatment, the heart rate was gradually increased to 130-140 bpm as the infant's thyroid function was improved (TSH 79.8 µIU/ml, free T3 2.95 pg/dl, and free T4 1.66 ng/dl on day 22). The infant was diagnosed ectopic thyroid tissue because of the high thyroglobulin level (85.9 µg/l). In conclusion, congenital hypothyroidism should be included in the differential diagnosis in cases of fetal bradycardia without cardiac anomalies or maternal autoimmune diseases.


Subject(s)
Bradycardia/complications , Choristoma/complications , Congenital Hypothyroidism/complications , Coronary Sinus/abnormalities , Fetus/abnormalities , Thyroid Gland/abnormalities , Bradycardia/diagnostic imaging , Electrocardiography , Female , Humans , Infant , Infant, Newborn , Lower Extremity/diagnostic imaging , Male , Neck/diagnostic imaging
14.
Heart Rhythm ; 16(10): 1545-1551, 2019 10.
Article in English | MEDLINE | ID: mdl-31330187

ABSTRACT

BACKGROUND: Catheter ablation of ganglionated plexus (GP) as cardioneuroablation in the left atrium (LA) has been used to treat vasovagal syncope (VVS). OBJECTIVE: The purpose of this study was to assess the effects of ablation of GPs on heart rate and to observe the acute, short-term, and long-term effects after cardioneuroablation. METHODS: A total of 115 consecutive patients with VVS who underwent cardioneuroablation were enrolled. GPs of the LA were identified by high-frequency stimulation and/or anatomic landmarks being targeted by radiofrequency catheter ablation. RESULTS: During ablation of right anterior ganglionated plexus (RAGP), heart rate increased from 61.3 ± 12.2 bpm to 82.4 ± 14.7 bpm (P <.001), whereas during ablation of other GPs only vagal responses were observed. During follow-up of 21.4 ± 13.1 months (median 18 months), 106 participants (92.2%) had no recurrence of syncope or presyncope. Holter data showed that minimal heart rate significantly increased at all follow-up time points (all P<.05), and mean heart rate remained higher than baseline 12 months after ablation (P = .001). CONCLUSION: Cardioneuroablation via GP ablation in the LA effectively inhibited the recurrence of VVS. Ablation of RAGP could increase heart rate immediately and for the long term. This unique phenomenon may provide a new potential approach for treatment of neural reflex syncope or bradyarrhythmias.


Subject(s)
Bradycardia/surgery , Catheter Ablation/methods , Imaging, Three-Dimensional , Syncope, Vasovagal/surgery , Vagus Nerve/surgery , Adult , Age Factors , Bradycardia/diagnostic imaging , Bradycardia/mortality , Cardiac Electrophysiology , Catheter Ablation/mortality , Cohort Studies , Electrocardiography, Ambulatory/methods , Female , Heart Atria/physiopathology , Humans , Male , Middle Aged , Prognosis , Retrospective Studies , Risk Assessment , Sex Factors , Syncope, Vasovagal/diagnosis , Syncope, Vasovagal/mortality , Treatment Outcome , Vagus Nerve/physiopathology
16.
J Cardiothorac Vasc Anesth ; 33(10): 2797-2803, 2019 Oct.
Article in English | MEDLINE | ID: mdl-30770181

ABSTRACT

The need for temporary cardiac pacing may occur in emergency and elective situations and may require transvenous right ventricular lead placement. The treatment of bradyarrhythmias presents the most common perioperative emergency indication. Intraoperatively, temporary rapid right ventricular pacing is accepted as a safe, titratable, and highly reliable method to achieve deliberate hypotension, and it has become a routine practice in the anesthetic management of cardiovascular interventions. The navigation of the lead into the right ventricle often requires fluoroscopy to guide placement and to confirm position. Ultrasound guidance has been accepted widely by perioperative physicians as a safe technique for central venous access. Basic ultrasound and transthoracic echocardiographic skills rapidly are becoming integral to anesthesiologists' practice. When used to guide transvenous pacemaker wire insertion, subcostal echocardiographic imaging offers attractive advantages over blind or fluoroscopic placement, including rapid deployment, avoidance of radiation, real-time visualization of the lead in relation to the cardiac structures, and early detection of potential complications, such as tamponade. Although several articles on echocardiographic guidance for transvenous pacing have been published in other acute care specialty fields in the last decade, this is the first description of the technique and of the recommended echocardiographic views in a perioperative context. In addition, a review of the current literature is presented, and the specific advantages and disadvantages of the approach are discussed in this article.


Subject(s)
Cardiac Catheterization/methods , Cardiac Pacing, Artificial/methods , Echocardiography/methods , Heart Ventricles/diagnostic imaging , Monitoring, Intraoperative/methods , Pacemaker, Artificial , Bradycardia/diagnostic imaging , Bradycardia/etiology , Cardiac Catheterization/adverse effects , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/methods , Heart Ventricles/surgery , Humans , Pacemaker, Artificial/adverse effects
18.
Medicina (Kaunas) ; 54(3)2018 Jul 12.
Article in English | MEDLINE | ID: mdl-30344280

ABSTRACT

Background and objective: Hypotension and bradycardia are the most common hemodynamic disorders and side effects of spinal anesthesia (SA) on the cardiovascular system. SA-induced sympathetic denervation causes peripheral vasodilatation and redistribution of central blood volume that may lead to decreased venous return to the heart. The aim of the study was to evaluate the changes of inferior vena cava collapsibility index (IVC-CI) during SA in spontaneously breathing patients during elective knee joint replacement surgery to prognose manifestation of intraoperative hypotension and bradycardia. Materials and methods: 60 patients (American Society of Anesthesiologists (ASA) physical status I or II, no clinically significant cardiovascular pathology) of both sexes undergoing elective knee joint replacement surgery under SA were included in the prospective study. Inspiratory and expiratory inferior vena cava (IVCin, IVCex) diameters were measured using an ultrasound device in supine position before and immediately after SA, then 15 min, 30 min, and 45 min after SA was performed. The heart rate, along with systolic, diastolic, and mean arterial blood pressures were collected. The parameters were measured at the baseline and at the next four time points. Results: There were no significant changes in IVCin, IVCex, and IVC-CI compared to baseline and other time point measurements in hypotensive versus nonhypotensive and bradycardic versus nonbradycardic patients (p > 0.05). Changes in IVC diameter do not prognose hypotension and/or bradycardia during SA: the area under the curve (AUC) of the receiver operating characteristic (ROC) curve for IVC-CI at all measuring points was <0.7, p > 0.05. Conclusions: Reduction in IVC diameters and increase in IVC-CI do not predict hypotension and bradycardia during SA in spontaneously breathing patients undergoing elective knee joint replacement surgery.


Subject(s)
Anesthesia, Spinal/adverse effects , Bradycardia/diagnostic imaging , Hypotension/diagnostic imaging , Intraoperative Complications/diagnostic imaging , Ultrasonography/statistics & numerical data , Aged , Arthroplasty, Replacement, Knee/adverse effects , Bradycardia/chemically induced , Elective Surgical Procedures/adverse effects , Female , Humans , Hypotension/chemically induced , Intraoperative Complications/chemically induced , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , ROC Curve , Ultrasonography/methods , Vena Cava, Inferior/diagnostic imaging