Results 1 - 20 de 1.971
Filter
1.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38696675

ABSTRACT

AIMS: Contact force (CF)-sensing radiofrequency (RF) catheters with an ablation index have shown reproducible outcomes for the treatment of atrial fibrillation (AF) in large multicentre studies. A dual-energy (DE) focal CF catheter to deliver RF and unipolar/biphasic pulsed field ablation (PFA), integrated with a three-dimensional (3D) mapping system, can provide operators with additional flexibility. The SmartfIRE study assessed the safety and efficacy of this novel technology for the treatment of drug-refractory, symptomatic paroxysmal AF. Results at 3 months post-ablation are presented here. METHODS AND RESULTS: Pulmonary vein isolation (PVI) was performed using a DE focal, irrigated CF-sensing catheter with the recommendation of PFA at posterior/inferior and RF ablation at the anterior/ridge/carina segments. Irrespective of energy, a tag size of 3 mm; an inter-tag distance ≤6 mm; a target index of 550 for anterior, roof, ridge, and carina; and a target index of 400 for posterior and inferior were recommended. Cavotricuspid isthmus ablation was permitted in patients with documented typical atrial flutter. The primary effectiveness endpoint was acute procedural success. The primary safety endpoint was the rate of primary adverse events (PAEs) within 7 days of the procedure. A prespecified patient subset underwent oesophageal endoscopy (EE; 72 h post-procedure), neurological assessment (NA; pre-procedure and discharge), and cardiac computed tomography (CT)/magnetic resonance angiogram (MRA) imaging (pre-procedure and 3 months post-procedure) for additional safety evaluation, and a mandatory remapping procedure (Day 75 ± 15) for PVI durability assessment. Of 149 patients enrolled between February and June 2023, 140 had the study catheter inserted (safety analysis set) and 137 had ablation energy delivered (per-protocol analysis set). The median (Q1/Q3) total procedure and fluoroscopy times were 108.0 (91.0/126.0) and 4.2 (2.3/7.7) min (n = 137). The acute procedural success rate was 100%. First-pass isolation was achieved in 89.1% of patients and 96.8% of veins. Cavotricuspid isthmus ablations were successfully performed in 12 patients [pulsed field (PF) only: 6, RF only: 5, and RF/PF: 1]. The PAE rate was 4.4% [6/137 patients; 2 pulmonary vein (PV) stenoses, 2 cardiac tamponades/perforations, 1 stroke, and 1 pericarditis]. No coronary artery spasm was reported. No oesophageal lesion was seen in the EE subset (0/31, 0%). In the NA subset (n = 30), microemboli lesions were identified in 2 patients (2/30, 6.7%), both of which were resolved at follow-up; only 1 was symptomatic (silent cerebral lesion, 3.3%). In the CT/MRA subset (n = 30), severe PV narrowing (of >70%) was detected in 2 patients (2/30, 6.7%; vein level 2/128, 1.6%), of whom 1 underwent dilatation and stenting and 1 was asymptomatic; both were associated with high index values and a small inter-tag distance. In the PV durability subset (n = 30), 100/115 treated PVs (87%) were durably isolated and 18/30 patients (60.0%) had all PVs durably isolated. CONCLUSION: A DE focal CF catheter with 3D mapping integration showed a 100% acute success rate with an acceptable safety profile in the treatment of paroxysmal AF. Prespecified 3-month remapping showed notable PVI durability. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05752487.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Male , Female , Catheter Ablation/methods , Catheter Ablation/instrumentation , Middle Aged , Treatment Outcome , Aged , Imaging, Three-Dimensional , Cardiac Catheters , Time Factors , Equipment Design , Prospective Studies , Recurrence
2.
Circ Cardiovasc Interv ; 17(5): e013302, 2024 May.
Article in English | MEDLINE | ID: mdl-38771909

ABSTRACT

Drug-coated balloons (DCBs) are specialized coronary devices comprised of a semicompliant balloon catheter with an engineered coating that allows the delivery of antiproliferative agents locally to the vessel wall during percutaneous coronary intervention. Although DCBs were initially developed more than a decade ago, their potential in coronary interventions has recently sparked renewed interest, especially in the United States. Originally designed to overcome the limitations of conventional balloon angioplasty and stenting, they aim to match or even improve upon the outcomes of drug-eluting stents without leaving a permanent implant. Presently, in-stent restenosis is the condition with the most robust evidence supporting the use of DCBs. DCBs provide improved long-term vessel patency compared with conventional balloon angioplasty and may be comparable to drug-eluting stents without the need for an additional stent layer, supporting their use as a first-line therapy for in-stent restenosis. Beyond the treatment of in-stent restenosis, DCBs provide an additional tool for de novo lesions for a strategy that avoids a permanent metal scaffold, which may be especially useful for the management of technically challenging anatomies such as small vessels and bifurcations. DCBs might also be advantageous for patients with high bleeding risk due to the decreased necessity for extended antiplatelet therapy, and in patients with diabetes and patients with diffuse disease to minimize long-stented segments. Further studies are crucial to confirm these broader applications for DCBs and to further validate safety and efficacy.


Subject(s)
Angioplasty, Balloon, Coronary , Cardiac Catheters , Cardiovascular Agents , Coated Materials, Biocompatible , Coronary Artery Disease , Coronary Restenosis , Humans , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/adverse effects , Treatment Outcome , Coronary Restenosis/etiology , Coronary Restenosis/therapy , Cardiovascular Agents/administration & dosage , Cardiovascular Agents/adverse effects , Equipment Design , Risk Factors , Vascular Patency , Drug-Eluting Stents
3.
Scand Cardiovasc J ; 58(1): 2347295, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38706409

ABSTRACT

Objectives. This study investigated the influence of higher pressure protection with a small diameter balloon of side branch (SB) on bifurcation lesions. Background. Of the different coronary stent implantation techniques, the modified jailed balloon technique has become a viable option for bifurcation lesions. However, there was no detailed study on the relationship between the balloon inflation pressure of the main vessel (MV) and SB. Methods. In this study, we collected information of patients who underwent percutaneous coronary intervention (PCI) for bifurcated lesions between March 2019 and December 2022. They were divided into two groups according to the operation way: active jailed balloon technique (A-JBT) group and jailed wire technique (JWT) group. Results. A total of 216 patients were enrolled. The A-JBT group had a larger SB stenosis diameter (1.53 ± 0.69 vs. 0.95 ± 0.52, p < .001), the lower degree of stenosis (44.34 ± 18.30 vs. 63.69 ± 17.34, p < .001) compared to the JWT group. However, the JWT group had a higher incidence of SB occlusion (18.0% vs. 1.9%, p < .001) compared to the A-JBT group. Nevertheless, the success rate for both groups was 100%. Conclusions. This novel high inflation pressure and small diameter balloon approach we propose has significant advantages. There is a lower rate of SB occlusion and SB dissection, which is more cost-effective and provides better clinical outcomes for the patient. This method should be considered in the future for treating bifurcation lesions.


Subject(s)
Angioplasty, Balloon, Coronary , Cardiac Catheters , Coronary Artery Disease , Humans , Male , Female , Aged , Middle Aged , Treatment Outcome , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/adverse effects , Retrospective Studies , Stents , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/therapy , Coronary Stenosis/surgery , Risk Factors , Pressure , Time Factors , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation
5.
Circ Arrhythm Electrophysiol ; 17(5): e012667, 2024 May.
Article in English | MEDLINE | ID: mdl-38655693

ABSTRACT

BACKGROUND: We previously presented the safety and early efficacy of the inspIRE study (Study for Treatment of Paroxysmal Atrial Fibrillation [PAF] by Pulsed-field Ablation [PFA] System With Irreversible Electroporation [IRE]). With the study's conclusion, we report the outcomes of the full pivotal study cohort, with an additional analysis of predictors of success. METHODS: InspIRE was a prospective, multicenter, single-arm clinical trial of drug-refractory paroxysmal atrial fibrillation. Pulmonary vein isolation was performed with a variable-loop circular catheter integrated with a 3-dimensional mapping system. Follow-up with 24-hour Holter was at 3, 6, and 12 months, as well as remote rhythm monitoring: weekly from 3 to 5 months, monthly from 6 to 12 months, and for symptoms. The primary effectiveness end point (PEE) was acute pulmonary vein isolation plus freedom from any atrial arrhythmia at 12 months. Additional subanalyses report predictors of PEE success. RESULTS: The patient cohort included 186 patients: aged 59±10 years, female 30%, and CHA2DS2-VASc 1.3±1.2. The previously reported primary adverse event rate was 0%. One serious procedure-related adverse event, urinary retention, was reported. The PEE was achieved in 75.6% (95% CI, 69.5%-81.8%). The clinical success of freedom from symptomatic recurrence was 81.7% (95% CI, 76.1%-87.2%). Simulating a monitoring method used in standard real-world practice (without protocol-driven remote rhythm monitoring), this translates to a freedom from all and symptomatic recurrence of 85.8% (95% CI, 80.8%-90.9%) or 94.0% (95% CI, 90.6%-97.5%), respectively. Multivariate analyses revealed that left ventricular ejection fraction ≥60% (adjusted odds ratio, 0.30) and patients receiving ≥48 PFA applications (adjusted odds ratio, 0.28) were independent predictors of PEE success. Moreover, PEE success was 79.2% in patients who received ≥12 PFA applications per vein compared with 57.1% in patients receiving fewer PFA applications. CONCLUSIONS: The inspIRE study confirms the safety and effectiveness of pulmonary vein isolation using the novel 3-dimensional mapping integrated circular loop catheter. An optimal number of PFA applications (≥48 total or ≥12 per vein) resulted in an improved 1-year success rate of ≈80%. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04524364.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Female , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Male , Middle Aged , Catheter Ablation/instrumentation , Catheter Ablation/methods , Catheter Ablation/adverse effects , Prospective Studies , Aged , Time Factors , Heart Rate , Action Potentials , Electrocardiography, Ambulatory/instrumentation , Recurrence , Cardiac Catheters , Predictive Value of Tests , Treatment Outcome , Imaging, Three-Dimensional , Risk Factors , Equipment Design , Electrophysiologic Techniques, Cardiac
6.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38584468

ABSTRACT

AIMS: Pulsed field ablation (PFA) has significant advantages over conventional thermal ablation of atrial fibrillation (AF). This first-in-human, single-arm trial to treat paroxysmal AF (PAF) assessed the efficiency, safety, pulmonary vein isolation (PVI) durability and one-year clinical effectiveness of an 8 Fr, large-lattice, conformable single-shot PFA catheter together with a dedicated electroanatomical mapping system. METHODS AND RESULTS: After rendering the PV anatomy, the PFA catheter delivered monopolar, biphasic pulse trains (5-6 s per application; ∼4 applications per PV). Three waveforms were tested: PULSE1, PULSE2, and PULSE3. Follow-up included ECGs, Holters at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy endpoints were acute PVI and post-blanking atrial arrhythmia recurrence, respectively. Invasive remapping was conducted ∼75 days post-ablation. At three centres, PVI was performed by five operators in 85 patients using PULSE1 (n = 30), PULSE2 (n = 20), and PULSE3 (n = 35). Acute PVI was achieved in 100% of PVs using 3.9 ± 1.4 PFA applications per PV. Overall procedure, transpired ablation, PFA catheter dwell and fluoroscopy times were 56.5 ± 21.6, 10.0 ± 6.0, 19.1 ± 9.3, and 5.7 ± 3.9 min, respectively. No pre-defined primary safety events occurred. Upon remapping, PVI durability was 90% and 99% on a per-vein basis for the total and PULSE3 cohort, respectively. The Kaplan-Meier estimate of one-year freedom from atrial arrhythmias was 81.8% (95% CI 70.2-89.2%) for the total, and 100% (95% CI 80.6-100%) for the PULSE3 cohort. CONCLUSION: Pulmonary vein isolation (PVI) utilizing a conformable single-shot PFA catheter to treat PAF was efficient, safe, and effective, with durable lesions demonstrated upon remapping.


Subject(s)
Atrial Fibrillation , Cardiac Catheters , Catheter Ablation , Pulmonary Veins , Recurrence , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Catheter Ablation/methods , Catheter Ablation/instrumentation , Male , Female , Middle Aged , Aged , Treatment Outcome , Equipment Design , Electrophysiologic Techniques, Cardiac , Time Factors , Heart Rate , Action Potentials
10.
Circ Cardiovasc Interv ; 17(5): e013898, 2024 May.
Article in English | MEDLINE | ID: mdl-38533653

ABSTRACT

BACKGROUND: Acute aortic regurgitation is life-threatening with few nonsurgical options for immediate stabilization. We propose Trans-Aortic Balloon to Ease Regurgitation Applying Counter-Pulsation (TABERNACL), a simple, on-table temporary valve using commercially available equipment to temporize acute severe aortic regurgitation. METHODS: We hypothesize that an appropriately sized commercial balloon dilatation catheter-straddling the aortic annulus and connected to a counterpulsation console-can serve as a temporizing valve to restore hemodynamic stability in acute aortic regurgitation. We performed benchtop testing of valvuloplasty, angioplasty, and sizing balloons as counterpulsation balloons. TABERNACL was assessed in vivo in a porcine model of acute aortic regurgitation (n=8). We also tested a static undersized, continuously inflated transvalvular balloon as a spacer intended physically to obstruct the regurgitant orifice. RESULTS: Benchtop testing identified that Tyshak II and PTS sizing (NuMed Braun) balloon catheters performed adequately as temporary valves (ie, complete inflation and deflation with each cycle) and resisted fatigue, in contrast to others. When TABERNACL was used in the acute severe regurgitation animals, there was immediate hemodynamic improvement, with a significant 35% increase in diastolic aortic pressure by 16 mm Hg ([95% CI, 7-25] P=0.0056), 34% reduction in left ventricular end-diastolic pressure by -7 mm Hg ([95% CI, -10 to -5] P=0.0006), improvement in the aortic diastolic index by 0.28 ([95% CI, 0.18-0.39] P=0.0009), and reversal of electrocardiographic myocardial ischemia. As an alternative, static balloon inflation across the aortic valve stabilized regurgitation hemodynamics at the expense of a new aortic gradient and caused excessive ectopy from balloon movement in the left ventricular outflow tract. CONCLUSIONS: TABERNACL improves hemodynamics and reduces coronary ischemia by electrocardiography in animals with acute severe aortic regurgitation. TABERNACL valves obstruct the diastolic regurgitant orifice without systolic obstruction. This may prove a lifesaving bridge to definitive valve replacement therapy.


Subject(s)
Aortic Valve Insufficiency , Balloon Valvuloplasty , Disease Models, Animal , Hemodynamics , Animals , Hemodynamics/drug effects , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/diagnostic imaging , Sus scrofa , Aortic Valve/physiopathology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Equipment Design , Recovery of Function , Acute Disease , Cardiac Catheters , Time Factors , Severity of Illness Index , Ventricular Function, Left/drug effects
11.
J Cardiovasc Electrophysiol ; 35(5): 886-894, 2024 May.
Article in English | MEDLINE | ID: mdl-38433316

ABSTRACT

INTRODUCTION: Through systematic scientific rigor, the CLOSE guided workflow was developed and has been shown to improve pulmonary vein isolation durability. However, this technique was developed at a time when using power-controlled ablation catheters with conventional power ranges was the norm. There has been increased adoption of a high-power and very high-power short-duration ablation practice propelled by the availability of the temperature-controlled radiofrequency QDOT MICRO catheter. METHODS: There are fundamental differences in biophysics between very high-powered temperature guided ablation and conventional ablation strategy that may impact patient outcomes. The catheter's design and ablation modes offer flexibility in technique while accommodating the individual operator's clinical discretion and preference to deliver a durable, transmural, and contiguous lesion set. RESULTS: Here, we provide recommendations for 3 different workflows using the QDOT MICRO catheter in a step-by-step manner for pulmonary vein isolation based on our cumulative experience as early adopters of the technology and the data available in the scientific literature. CONCLUSIONS: With standardization, temperature-controlled ablation with the QDOT MICRO catheter provides operators the flexibility of implementing different ablation strategies to ensure durable contiguous pulmonary vein isolation depending on patient characteristics.


Subject(s)
Atrial Fibrillation , Cardiac Catheters , Catheter Ablation , Equipment Design , Pulmonary Veins , Humans , Action Potentials , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Catheter Ablation/instrumentation , Heart Rate , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Temperature , Time Factors , Treatment Outcome , Workflow
12.
Catheter Cardiovasc Interv ; 103(6): 1035-1041, 2024 May.
Article in English | MEDLINE | ID: mdl-38545668

ABSTRACT

A distinctive complication with balloon-expandable (BE) THV platforms such as the Edwards Sapien (Edwards Lifescience) is the possibility of balloon rupture during THV deployment. Balloon rupture is a rare occurrence that can result in stroke due to fragment embolism, incomplete THV expansion, and/or vascular injury upon retrieval of the balloon. Careful evaluation of preoperative computed tomography is essential to identify high-risk cases. While annular and left ventricular outflow tract (LVOT) calcification are widely acknowledged as common risks for balloon injury, it's essential to note that balloon injury can manifest at various anatomical sites. In this review, we discuss the mechanism behind balloon rupture, methods to identify cases at a heightened risk of balloon injury, approaches to mitigate the risk of rupture, and percutaneous retrieval strategies.


Subject(s)
Balloon Valvuloplasty , Equipment Failure , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Balloon Valvuloplasty/adverse effects , Balloon Valvuloplasty/instrumentation , Cardiac Catheters , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome
13.
JACC Clin Electrophysiol ; 10(4): 762-767, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38456859

ABSTRACT

Current catheter designs used for radiofrequency (RF) in cardiac tissue achieve limited ablation depth as lesion size is driven heavily by resistive heating at the tissue surface. A catheter with a truncated, dome-shaped tip with a toroidal surface designed for focal RF ablation was recently described. This in vivo study compares lesion characteristics between a second-generation focused electric field (FEF) catheter vs a standard irrigated catheter using RF energy in a beating heart model. We performed in vivo ablations using RF energy with the FEF ablation catheter tip (Focused Therapeutics) and an irrigated Blazer catheter (Boston Scientific) under identical power, duration, and irrigation rates. In addition, RF dosing at high power and duration was examined using the FEF catheter. Intracardiac echocardiography was used to evaluate steam pops and catheter tip angle relative to the tissue surface. Studies were terminal and lesion size was measured following 2,3,5-triphenyltetrazolium chloride staining. Ablations were performed in 6 swine (FEF, n = 31; control, n = 8). FEF ablation lesions (n = 7) were deeper (15.6 ± 2.6 mm vs 7.5 ± 1.9 mm; P < 0.001) and wider (18.4 ± 2.9 mm vs 12.6 ± 2.4 mm; P < 0.001) than lesions delivered with the control irrigated catheter (n = 8) under the same parameters. Thirty-two percent (n = 10 of 31) of lesions delivered from the left ventricle endocardial surface using the FEF catheter were transmural. No steam pops were observed with delivery of FEF lesions (n = 31). The angle of incidence did not significantly affect FEF lesion size. In this in vivo preclinical study, the FEF catheter, which provides focused energy delivery, resulted in significantly larger lesions than the irrigated control catheter without steam pops. Approximately one-third of ablations with the FEF catheter delivered from the endocardial left ventricular surface resulted in transmural lesions.


Subject(s)
Cardiac Surgical Procedures , Catheter Ablation , Animals , Cardiac Catheters , Catheter Ablation/instrumentation , Catheter Ablation/methods , Echocardiography , Equipment Design , Swine , Cardiac Surgical Procedures/instrumentation , Cardiac Surgical Procedures/methods
15.
Coron Artery Dis ; 35(4): 309-313, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38411142

ABSTRACT

BACKGROUND: The role of coronary artery spasm (CAS) was extended beyond variant angina to ischemic heart disease in general, including effort angina, unstable angina, acute myocardial infarction (MI) and sudden death. It is difficult and cumbersome to examine CAS during coronary angiography. Risk factors for CAS include smoking and genetic polymorphisms. AIM: We aimed to investigate the association of the interleukin-6 (IL-6) polymorphism with catheter-induced CAS in Egyptian patients who undergo coronary angiography. METHODS: This is a case-control study. Two hundred patients with chronic coronary artery disease who underwent elective coronary angiography were included in the study. Patients were divided into two groups: the non-CAS group (100 patients) and the CAS group (100 patients). The subjects were genotyped to the -572 C>G (rs 1800796) polymorphism of the IL-6 gene by PCR-restriction fragment length polymorphism. RESULTS: We found that patients with CAS have more risk factors for atherosclerosis compared to those without CAS. Smoking, the IL-6 GG genotype, and the G allele were independent risk factors for CAS. CONCLUSION: We concluded that the GG genotype and G allele of the IL-6 gene are associated with CAS. Smoking, the GG genotype, and the G allele of the IL-6 gene are independent predictors of catheter-induced CAS.


Subject(s)
Coronary Angiography , Coronary Vasospasm , Genetic Predisposition to Disease , Interleukin-6 , North African People , Smoking , Humans , Egypt/epidemiology , Male , Female , Middle Aged , Interleukin-6/genetics , Coronary Vasospasm/genetics , Coronary Vasospasm/diagnosis , Coronary Vasospasm/epidemiology , Case-Control Studies , Risk Factors , Smoking/adverse effects , Smoking/epidemiology , Aged , Cardiac Catheterization , Gene Frequency , Phenotype , Cardiac Catheters , Genetic Association Studies , Polymorphism, Single Nucleotide , Polymorphism, Genetic
17.
J Invasive Cardiol ; 36(4)2024 Apr.
Article in English | MEDLINE | ID: mdl-38412436

ABSTRACT

Atrial septal abnormalities are common congenital lesions that remain asymptomatic in many patients until adulthood. Adults with atrial septal defects (ASD) most commonly have ostium secundum ASD. Transcatheter closure has become increasingly popular in recent years as a successful alternative method to surgery for treating ASD and patent foramen ovale (PFO). The overall rate of ASD transcatheter closure device embolization has been reported to be less than 1%; however, retrieving the device via surgery or by trans-catheter route can be necessary. The current manuscript describes a systematic review of the techniques used to retrieve ASD closure devices, as well as their success rates, complications, and limitations. A comprehensive search was performed covering various databases including PubMed, MEDLINE, SCOPUS, Google Scholar, and Cochrane Library from inception until April 2022 for English-published case reports, case series, and experimental studies investigating the indications, safety, and limitations of ASD closure and ASD device retrieval by trans-catheter approaches. Finally, 20 studies were included in our review. Our findings showed that most of the studies used a single snare technique; of these, all but one reported 100% success. Double tool retrieval methods (snare plus snare, snare plus bioptome, or snare plus forceps) and the gooseneck snare technique yielded 100% success. One study that used the lasso technique reported unsuccessful retrieval and the need for surgical intervention. More recently, the novel "coronary wire trap technique" was introduced, which provides a simpler method for embolized device removal by trapping the device for retrieval using coronary wire.


Subject(s)
Foramen Ovale, Patent , Heart Septal Defects, Atrial , Septal Occluder Device , Adult , Humans , Foramen Ovale, Patent/surgery , Treatment Outcome , Cardiac Catheterization/methods , Heart Septal Defects, Atrial/diagnosis , Heart Septal Defects, Atrial/surgery , Cardiac Catheters
19.
Acta Neurochir (Wien) ; 166(1): 44, 2024 Jan 29.
Article in English | MEDLINE | ID: mdl-38282032

ABSTRACT

BACKGROUND: In intraventricular surgery using a flexible endoscope, the lesion is usually aspirated via the working channel. However, the surgical view during aspiration is extremely poor because the objective lens is located adjacent to the working channel. METHOD: To address this issue, we developed a novel surgical procedure using an angiographic catheter. In this procedure, the catheter is inserted into the working channel, and the lesion is aspirated through the catheter. Besides, continuous intraventricular irrigation is performed via the gap between the catheter and the working channel. CONCLUSION: This procedure maintains a clear view during surgery and reduces complications.


Subject(s)
Endoscopy , Neuroendoscopy , Humans , Endoscopy/methods , Endoscopes , Cardiac Catheters , Catheters , Neuroendoscopy/methods
20.
J Comp Eff Res ; 13(3): e230053, 2024 03.
Article in English | MEDLINE | ID: mdl-38261335

ABSTRACT

Aim: Catheter ablation is used to treat symptomatic atrial fibrillation (AF) and is performed using either cryoballoon (CB) or radiofrequency (RF) ablation. There is limited real world data of CB and RF in the US as healthcare codes are agnostic of energy modality. An alternative method is to analyze patients' electronic health records (EHRs) using Optum's EHR database. Objective: To determine the feasibility of using patients' EHRs with natural language processing (NLP) to distinguish CB versus RF ablation procedures. Data Source: Optum® de-identified EHR dataset, Optum® Cardiac Ablation NLP Table. Methods: This was a retrospective analysis of existing de-identified EHR data. Medical codes were used to create an ablation validation table. Frequency analysis was used to assess ablation procedures and their associated note terms. Two cohorts were created (1) index procedures, (2) multiple procedures. Possible note term combinations included (1) cryoablation (2) radiofrequency (3) ablation, or (4) both. Results: Of the 40,810 validated cardiac ablations, 3777 (9%) index ablation procedures had available and matching NLP note terms. Of these, 22% (n = 844) were classified as ablation, 27% (n = 1016) as cryoablation, 49% (n = 1855) as radiofrequency ablation, and 1.6% (n = 62) as both. In the multiple procedures analysis, 5691 (14%) procedures had matching note terms. 24% (n = 1362) were classified as ablation, 27% as cryoablation, 47% as radiofrequency ablation, and 2% as both. Conclusion: NLP has potential to evaluate the frequency of cardiac ablation by type, however, for this to be a reliable real-world data source, mandatory data entry by providers and standardized electronic health reporting must occur.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Treatment Outcome , Cardiac Catheters , Retrospective Studies , Electronic Health Records , Natural Language Processing , Atrial Fibrillation/surgery , Catheter Ablation/methods