Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 10.379
Filter
1.
J Agric Food Chem ; 72(19): 11051-11061, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38698723

ABSTRACT

Multiple analytical methodologies allow quantitation of H2S and methanethiol (MeSH) in wine, but confirmation that the determined concentrations are related to perceived off-aromas, or "reductive" faults, is yet to be provided. Fifty white wines underwent sensory evaluation and measurement of free and salt-treated H2S and MeSH concentrations by gas chromatography with sulfur chemiluminescence detection and/or gas detection tubes. The determined concentrations were compared across techniques and different analysis laboratories. Sulfhydryl off-odors in the wines were best described by boiled and rotten egg and natural gas/sewerage/durian aroma attributes. The wines with the highest ratings for both aromas had high concentrations of free H2S, free MeSH, and/or salt-treated MeSH but were unrelated to salt-treated H2S. The free sulfhydryl concentrations and their associated aromas appeared to be suppressed by specific Cu fractions in the wines. This study provides evidence of the relevant measures of reductive aroma compounds and their relation to off-odors and Cu fractions.


Subject(s)
Copper , Odorants , Sulfhydryl Compounds , Wine , Wine/analysis , Odorants/analysis , Sulfhydryl Compounds/analysis , Humans , Copper/analysis , Chromatography, Gas/methods , Taste , Hydrogen Sulfide/analysis , Female , Male , Adult , Oxidation-Reduction , Middle Aged , Smell , Volatile Organic Compounds/analysis , Volatile Organic Compounds/chemistry
2.
Se Pu ; 42(5): 481-486, 2024 Apr 08.
Article in Chinese | MEDLINE | ID: mdl-38736392

ABSTRACT

Ibandronate sodium, a third-generation diphosphate drug used worldwide to treat osteoporosis, has the advantages of convenient use, low toxicity, and significant therapeutic effects. However, the residual organic solvents in the synthesis process of sodium ibandronate not only have a negative impact on the efficacy of the drug, but also lead to a decrease in drug stability. Moreover, if the residual amounts of these solvents exceed safety standards, they may pose serious threats to human health. This study successfully established a convenient and efficient method based on headspace-gas chromatography (HS-GC) for the simultaneous determination of five residual solvents (methanol, acetone, benzene, toluene, 1-pentanol) in the raw materials of ibandronate sodium. The results indicated that satisfactory analytical performance can be achieved by using DB-624 capillary column (30 m×0.32 mm×1.8 µm) and a flame ionization detector in conjunction with headspace autosampling and a temperature program. The specific operating conditions included an initial temperature of 40 ℃, with a hold of 2 min, followed by a temperature ramp first to 200 ℃ at a rate of 5 ℃/min and then to 240 ℃ at a rate of 20 ℃/min, with a hold of 5 min. Nitrogen with a flow rate of 1 mL/min and split ratio of 14∶1 was used as the carrier gas. The headspace vial temperature was maintained at 80 ℃, and the sample equilibration time was 20 min. Under the established analytical conditions, good linear relationships were obtained between the mass concentrations of methanol (72-216 µg/mL), acetone (120-360 µg/mL), benzene (0.048-0.144 µg/mL), toluene (21.36-64.08 µg/mL), and 1-pentanol (120-360 µg/mL) and their corresponding peak areas, with correlation coefficients (r) greater than 0.990. The limits of detection for these solvents were 2.88, 0.011, 0.90, 0.24, and 0.024 ng/mL, respectively, with limits of quantification of 11.5, 0.043, 3.6, 0.96, and 0.096 ng/mL, respectively. Furthermore, the recoveries of these solvents ranged from 86.3% to 101.9%, with relative standard deviations (RSDs, n=3) of less than 2.49%. The proposed method is simple, accurate, reliable, and suitable for the rapid and simultaneous determination of five residual solvents in the raw materials of ibandronate sodium. This study has important practical significance in improving drug safety and ensuring public health.


Subject(s)
Ibandronic Acid , Solvents , Chromatography, Gas/methods , Solvents/chemistry , Ibandronic Acid/analysis , Diphosphonates/analysis , Drug Contamination
3.
Chirality ; 36(5): e23676, 2024 May.
Article in English | MEDLINE | ID: mdl-38736271

ABSTRACT

Among different substance classes, New Psychoactive Substances (NPS) comprise chiral amphetamines for stimulant and empathic effects. There is little knowledge in terms of clinical studies about possibly different effects of the two enantiomers of novel amphetamine derivatives. For this reason, there is a big demand for enantioseparation method development of this new substance class. Regarding gas chromatography, cyclodextrins proved to be effective for enantioseparation of NPS. In our attempt, an Astec® Chiraldex™ G-PN column containing 2,6-di-O-pentyl-3-propionyl-γ-cyclodextrin and a Lipodex™ D column containing heptakis-(2,6-di-O-pentyl-O-acetyl)-ß-cyclodextrin as chiral selector served as stationary phases in a Shimadzu GCMS-QP2010 SE system. Because of the special coating, maximum temperature is limited to 200 °C isothermal or 220 °C in programmed mode. To ensure detection, trifluoroacetic anhydride (TFAA) was used to increase sample volatility.1 As a result, 35 amphetamines were tested as their TFAA-derivatives. A screening method with a temperature gradient from 140 °C to 200 °C at a heating ramp of 1 °C per minute and final time of 5 min, showed baseline separation for seven and partial separations for 16 trifluoro acetylated amphetamines using the Chiraldex™ G-PN column. Six baseline and nine partial separations were observed with the Lipodex™ D column, respectively.


Subject(s)
Amphetamines , Stereoisomerism , Amphetamines/chemistry , Amphetamines/isolation & purification , Chromatography, Gas/methods , Cyclodextrins/chemistry , Temperature , Gas Chromatography-Mass Spectrometry/methods
4.
J Chromatogr A ; 1725: 464949, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38688054

ABSTRACT

This study introduces an innovative needle trap device (NTD) featuring a molecularly imprinted polymer (MIP) surface-modified Zeolite Y. The developed NTD was integrated with gas chromatography-flame ionization detector (GC-FID) and employed for analysis of fuel ether oxygenates (methyl tert­butyl ether, MTBE, ethyl tert­butyl ether, ETBE, and tert­butyl formate, TBF) in urine samples. To optimize the key experimental variables including extraction temperature, extraction time, salt concentration, and stirring speed, a central composite design-response surface methodology (CCD-RSM) was employed. The optimal values for extraction in the study were found to be 51.2 °C extraction temperature, 46.2 min extraction time, 27 % salt concentration, and 620 rpm stirring speed. Under the optimized conditions, the calibration curves demonstrated excellent linearity within the range of 0.1-100 µg L-1, with correlation coefficients (R2) exceeding 0.99. The limits of detection (LODs) for MTBE, ETBE, and TBF were obtained 0.06, 0.08, and 0.09 µg L-1, respectively. Moreover, the limits of quantification (LOQs) for MTBE, ETBE, and TBF were obtained 0.18, 0.24, and 0.27 µg L-1, respectively. The enrichment factor was also found to be in the range of 98-129.The NTD-GC-FID procedure demonstrated a high extraction efficiency, making it a promising tool for urinary biomonitoring of fuel ether oxygenates with improved sensitivity and selectivity compared to current methods.


Subject(s)
Limit of Detection , Methyl Ethers , Zeolites , Zeolites/chemistry , Humans , Methyl Ethers/urine , Methyl Ethers/chemistry , Molecularly Imprinted Polymers/chemistry , Biological Monitoring/methods , Chromatography, Gas/methods , Ethyl Ethers/urine , Ethyl Ethers/chemistry
5.
J Chromatogr A ; 1722: 464869, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38604057

ABSTRACT

Hydrodynamics, efficiency, and loading capacity of two semi-packed columns with different cross sections (NANO 315 µm x 18 µm; CAP 1000 µm x 28 µm) and similar pillar diameter and pillar-pillar distance (respectively 5 µm and 2.5 µm) have been compared in high-pressure gas chromatography. A flow prediction tool has been first designed to determine pressure variations and hold-up time across the chromatographic system taking into account the rectangular geometry of the ducts into the semi-packed columns. Intrinsic values of Height Equivalent to Theoretical Plate were determined for NANO and CAP columns using helium as carrier gas and similar values have been obtained (30 µm) for the two columns. Loading capacity of semi-packed columns were determined for decane at 70 °C using helium, and the highest value was obtained from CAP column (larger cross section and stationary phase content). Finally, significant HETP improvement (down to 15 µm) and peak shape were observed when carbon dioxide was used as carrier gas, suggesting mobile phase adsorption on stationary phase in high pressure conditions.


Subject(s)
Helium , Pressure , Chromatography, Gas/methods , Chromatography, Gas/instrumentation , Helium/chemistry , Hydrodynamics , Carbon Dioxide/chemistry , Adsorption
6.
J Pharm Biomed Anal ; 244: 116128, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38598924

ABSTRACT

Genotoxic impurities (GTIs) are potential carcinogens that need to be controlled down to ppm or lower concentration levels in pharmaceuticals under strict regulations. The static headspace gas chromatography (HS-GC) coupled with electron capture detection (ECD) is an effective approach to monitor halogenated and nitroaromatic genotoxins. Deep eutectic solvents (DESs) possess tunable physico-chemical properties and low vapor pressure for HS-GC methods. In this study, zwitterionic and non-ionic DESs have been used for the first time to develop and validate a sensitive analytical method for the analysis of 24 genotoxins at sub-ppm concentrations. Compared to non-ionic diluents, zwitterionic DESs produced exceptional analytical performance and the betaine : 7 (1,4- butane diol) DES outperformed the betaine : 5 (1,4-butane diol) DES. Limits of detection (LOD) down to the 5-ppb concentration level were achieved in DESs. Wide linear ranges spanning over 5 orders of magnitude (0.005-100 µg g-1) were obtained for most analytes with exceptional sensitivities and high precision. The method accuracy and precision were validated using 3 commercially available drug substances and excellent recoveries were obtained. This study broadens the applicability of HS-GC in the determination of less volatile GTIs by establishing DESs as viable diluent substitutes for organic solvents in routine pharmaceutical analysis.


Subject(s)
Deep Eutectic Solvents , Drug Contamination , Limit of Detection , Mutagens , Drug Contamination/prevention & control , Chromatography, Gas/methods , Mutagens/analysis , Pharmaceutical Preparations/analysis , Pharmaceutical Preparations/chemistry , Deep Eutectic Solvents/chemistry , Deep Eutectic Solvents/analysis , Green Chemistry Technology/methods , Reproducibility of Results , Solvents/chemistry
7.
J Agric Food Chem ; 72(17): 9523-9554, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38640191

ABSTRACT

Gas chromatography-olfactometry (GC-O) has made significant advancements in recent years, with breakthroughs in its applications and the identification of its limitations. This technology is widely used for analyzing complex odor patterns. The review begins by explaining the principles of GC-O, including sample preparation, separation methods, and olfactory evaluation techniques. It then explores the diverse range of applications where GC-O has found success, such as food and beverage industries, environmental monitoring, perfume and aroma development, and forensic analysis. One of the major breakthroughs in GC-O analysis is the improvement in separation power and resolution of odorants. Techniques like rapid GC, comprehensive two-dimensional GC, and multidimensional GC have enhanced the identification and quantification of odor-active chemicals. However, GC-O also has limitations. These include the challenges in detecting and quantifying trace odorants, dealing with matrix effects, and ensuring the repeatability and consistency of results across laboratories. The review examines these limitations closely and discusses potential solutions and future directions for improvement in GC-O analysis. Overall, this review presents a comprehensive overview of the recent advances in GC-O, covering breakthroughs, applications, and limitations. It aims to promote the wider usage of GC-O analysis in odor analysis and related industries. Researchers, practitioners, and anyone interested in leveraging the capabilities of GC-O in analyzing complex odor patterns will find this review a valuable resource. The article highlights the potential of GC-O and encourages further research and development in the field.


Subject(s)
Odorants , Olfactometry , Odorants/analysis , Olfactometry/methods , Chromatography, Gas/methods , Chromatography, Gas/instrumentation , Humans , Smell , Volatile Organic Compounds/analysis , Volatile Organic Compounds/chemistry
8.
Methods Mol Biol ; 2790: 427-438, 2024.
Article in English | MEDLINE | ID: mdl-38649585

ABSTRACT

The biological role of lipids goes far beyond the formation of a structural membrane bilayer platform for membrane proteins and controlling fluxes across the membranes. For example, in photosynthetic thylakoid membranes, lipids occupy well-defined binding niches within protein complexes and determine the structural organization of membrane proteins and their function by controlling generic physicochemical membrane properties. In this chapter, two-dimensional thin-layer chromatography (2D TLC) and gas chromatography (GC) techniques are presented for quantitative analysis of lipid classes and fatty acids in thylakoid membranes. In addition, lipid extraction methods from isolated thylakoid membranes and leaves are described together with a procedure for the derivatization of fatty acids to fatty acid methyl esters (FAME) that is required for GC analysis.


Subject(s)
Fatty Acids , Photosynthesis , Thylakoids , Thylakoids/metabolism , Chromatography, Thin Layer/methods , Chromatography, Gas/methods , Fatty Acids/metabolism , Fatty Acids/chemistry , Membrane Lipids/metabolism , Membrane Lipids/chemistry , Plant Leaves/metabolism , Plant Leaves/chemistry , Lipids/chemistry , Lipids/isolation & purification , Lipids/analysis
9.
Se Pu ; 42(4): 387-392, 2024 Apr.
Article in Chinese | MEDLINE | ID: mdl-38566428

ABSTRACT

The residual amount of halogenated solvents in olive oil is an important indicator of its quality. The National Olive Oil Quality Standard GB/T 23347-2021 states that the residual amount of individual halogenated solvents in olive oil should be ≤0.1 mg/kg and that the total residual amount of halogenated solvents should be ≤0.2 mg/kg. COI/T.20/Doc. No. 8-1990, which was published by the International Olive Council, describes the standard method used for the determination of halogenated solvents in olive oil. Unfortunately, this method is cumbersome, has poor repeatability and low automation, and is unsuitable for the detection and analysis of residual halogenated solvents in large quantities of olive oil. At present, no national standard method for determining residual halogenated solvents in olive oil is available in China. Thus, developing simple, efficient, accurate, and stable methods for the determination of residual halogenated solvents in olive oil is imperative. In this paper, a method based on automatic headspace gas chromatography was established for the determination of residual halogenated solvents, namely, chloroform, carbon tetrachloride, 1,1,1-trichloroethane, dibromochloromethane, tetrachloroethylene, and bromoform, in olive oil. The samples were processed as follows. After mixing, 2.00 g (accurate to 0.01 g) of the olive oil sample was added into a 20 mL headspace injection bottle and immediately sealed for headspace gas chromatography analysis. Blank virgin olive oil was used to prepare a standard working solution and the external standard method for quantification. The solvents used in the preparation of halogenated solvent standard intermediates were investigated and methanol was selected as a replacement for N,N-dimethylacetamide to prepare a halogenated solvent standard intermediate owing to its safety. The effects of different injection times (1, 2, 3, 4, 5, 6 s), equilibration temperatures (60, 70, 80, 90, 100, 110, 120 ℃), and equilibration times (4, 5, 8, 10, 20, 30, 40 min) of the headspace sampler on the detection of the residual amounts of the six halogenated solvents were investigated. The optimal injection time and equilibration temperature were 3 s and 90 ℃, respectively. The method demonstrated good analytical performance for the six halogenated solvents when the equilibration time was 30 min. A methodological study was conducted on the optimized method, and the results showed that the six halogenated solvents exhibited good linear relationships in the range of 0.002-0.200 mg/kg, with correlation coefficients of ≥0.9991. The limits of detection (LODs) and quantification (LOQs) of 1,1,1-trichloroethane and bromoform were 0.0006 and 0.002 mg/kg, respectively. The LODs and LOQs of chloroform, carbon tetrachloride, dibromochloromethane, and tetrachloroethylene were 0.0003 and 0.001 mg/kg, respectively. The average recoveries under different spiked levels were 85.53%-115.93%, and the relative standard deviations (n=6) were 1.11%-8.48%. The established method was used to analyze 13 olive oil samples available in the market. Although no halogenated solvents were detected in these samples, a limited number of samples does not represent all olive oils. Hence, monitoring residual halogenated solvents in olive oil remains necessary for its safe consumption. The LOQs of the method for the six halogenated solvents were significantly lower than that of the COI/T.20/Doc. No. 8-1990 standard method (0.02 mg/kg). In addition, the developed method can be conducted under short operation times with high precision and degree of automation as well as good accuracy. Thus, the proposed method is suitable for the determination and analysis of the residues of the six halogenated solvents in large batches of olive oil samples.


Subject(s)
Tetrachloroethylene , Trichloroethanes , Olive Oil , Solvents/analysis , Gas Chromatography-Mass Spectrometry/methods , Tetrachloroethylene/analysis , Chloroform/analysis , Carbon Tetrachloride/analysis , Chromatography, Gas/methods , Trihalomethanes
10.
J Synchrotron Radiat ; 31(Pt 3): 566-577, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38682274

ABSTRACT

Improving the scalability of tissue imaging throughput with bright, coherent X-rays requires identifying and mitigating artifacts resulting from the interactions between X-rays and matter. At synchrotron sources, long-term imaging of soft tissues in solution can result in gas bubble formation or cavitation, which dramatically compromises image quality and integrity of the samples. By combining in-line phase-contrast imaging with gas chromatography in real time, we were able to track the onset and evolution of high-energy X-ray-induced gas bubbles in ethanol-embedded soft tissue samples for tens of minutes (two to three times the typical scan times). We demonstrate quantitatively that vacuum degassing of the sample during preparation can significantly delay bubble formation, offering up to a twofold improvement in dose tolerance, depending on the tissue type. However, once nucleated, bubble growth is faster in degassed than undegassed samples, indicating their distinct metastable states at bubble onset. Gas chromatography analysis shows increased solvent vaporization concurrent with bubble formation, yet the quantities of dissolved gasses remain unchanged. By coupling features extracted from the radiographs with computational analysis of bubble characteristics, we uncover dose-controlled kinetics and nucleation site-specific growth. These hallmark signatures provide quantitative constraints on the driving mechanisms of bubble formation and growth. Overall, the observations highlight bubble formation as a critical yet often overlooked hurdle in upscaling X-ray imaging for biological tissues and soft materials and we offer an empirical foundation for their understanding and imaging protocol optimization. More importantly, our approaches establish a top-down scheme to decipher the complex, multiscale radiation-matter interactions in these applications.


Subject(s)
Synchrotrons , X-Rays , Animals , Gases/chemistry , Chromatography, Gas/methods , Ethanol/chemistry
11.
J Chromatogr A ; 1721: 464812, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38569297

ABSTRACT

In this work, a novel and efficient approach for sodium hypochlorite analysis is proposed via phase-conversion headspace technique, which is based on the gas chromatography (GC) detection of generated carbon dioxide (CO2) from the redox reaction of sodium hypochlorite with sodium oxalate. The data obtained by the proposed method suggest the high detecting precision and accuracy. In addition, the method has low detection limits (limit of quantification (LOQ) = 0.24 µg/mL), and the recoveries of added standard ranged from 98.33 to 101.27 %. The proposed phase-conversion headspace technique is efficient and automated, thereby offering an efficient strategy for highly efficient analysis of sodium hypochlorite and related products.


Subject(s)
Disinfectants , Sodium Hypochlorite , Disinfectants/analysis , Hypochlorous Acid , Chromatography, Gas/methods , Carbon Dioxide/analysis
12.
Methods Mol Biol ; 2789: 75-83, 2024.
Article in English | MEDLINE | ID: mdl-38506993

ABSTRACT

Various organic solvents are widely used in the manufacturing, processing, and purification of drug substances, drug products, formulations, excipients, etc. These solvents must be removed to the lowest amount permitted, as they do not possess any therapeutic advantages and may cause undesirable toxicities. Therefore, a rapid and sensitive analytical method for the quantitation of residual solvents is needed. The following chapter presents a static headspace gas chromatographic (HSGC) method for determining the concentration of common residual solvents in various nanoformulations. An efficient and sensitive HSGC method has been developed using PerkinElmer's headspace autosampler/gas chromatographic system with a flame ionization detector (FID) and validated according to the International Conference for Harmonization (ICH) guideline Q3C. The method validation indicates that the method is specific, linear, accurate, precise, and sensitive for the analyzed solvents. The method is suitable for the analysis of 13 residual solvents (methanol, ethanol, acetone, diethyl ether, 2-propanol, acetonitrile, 1-propanol, ethyl acetate, tetrahydrofuran, dichloromethane, chloroform, 1-butanol, and pyridine) and utilizes an Elite 624 Crossbond 6% cyanopropylphenyl, 94% dimethylpolysiloxanes column with helium as a carrier gas.


Subject(s)
Ethanol , Methanol , Chromatography, Gas/methods , Solvents/chemistry , Flame Ionization , Methanol/analysis
13.
Article in English | MEDLINE | ID: mdl-38460448

ABSTRACT

This work reports the characterization of the lipidic fraction of seven species of marine organisms gathered along the shoreline of the Po Delta Park of Emilia-Romagna Region (Italy) and of the north Adriatic Sea. Two species of oysters (Crassostrea gigas and Ostrea edulis), two species of clams (Chamelea gallina and Ruditapes philippinarum), one species of mussel (Mytilus galloprovincialis), one species of macroalgae (Ulva rigida), and one species of spiny dogfish (Squalus acanthias) were analyzed to characterize their fatty acids profile and related nutritional value. The lipid fraction was simultaneously extracted and transesterified into fatty acid methyl esters (FAMEs) by using a recently developed one-step microwave-assisted extraction/derivatization (MAED) method. The obtained FAMEs extract was analyzed by a rapid comprehensive multidimensional gas chromatography (GC × GC) method (30 min). The system was equipped with a reverse set of columns (polar × non-polar) connected through a reversed fill/flush flow modulator. The GC × GC system was coupled with a flame-ionization detector (FID) for both qualitative and quantitative purposes. The MAED- GC × GC-FID methodology was suitable in the context of samples containing high percentages of omega-3 PUFA. A total of 82 FAMEs were tentatively identified using standards, literature data, and the two-dimensional plot location. FAME profiles obtained with the proposed approach were comparable with reference methods (AOCS Ce 2b-11), showing no significant differences. Moreover, to determine the food nutritional value of the samples investigated, the most common nutritional indices (index of atherogenicity, index thrombogenicity, hypocholesterolemic/hypercholesterolemic ratio, health-promoting index, unsaturation index, and the fish lipid quality index) were calculated from FAME profiles. Among the samples investigated, Squalus acanthias presented the best nutritional score, while Ruditapes philippinarum had the worst score in 3 out of 6 indices.


Subject(s)
Aquatic Organisms , Edible Seaweeds , Fatty Acids , Ulva , Animals , Fatty Acids/analysis , Flame Ionization/methods , Microwaves , Chromatography, Gas/methods
14.
Article in Chinese | MEDLINE | ID: mdl-38538245

ABSTRACT

As a rapid, accurate and efficient analytical technique, gas chromatography is widely used in the detection of volatile organic compounds and inorganic small molecule toxins, and it is the main analytical method in the national testing standards for occupational health. The existing effective national standards of gas chromatography for the detection of some substances have low column efficiency, high toxicity of reagents, poor correlation of the standard curve and low desorption efficiency and other problems, some of which can be solved through method improvement. At the same time, with the use of new materials and new processes, new types of toxic substances are emerging, and there are still many occupational disease hazards of limited value without supporting detection methods, gas chromatography can be applied to the detection of some toxic substances to better complement the vacancy of China's occupational health detection methods. This paper analyzes the current situation of the application of gas chromatography in occupational health testing standards, discusses the improvement of some of these methods, and helps to promote the application and development of gas chromatography in occupational health testing.


Subject(s)
Air Pollutants, Occupational , Occupational Health , Air Pollutants, Occupational/analysis , Workplace , Chromatography, Gas/methods , China
15.
J Chromatogr A ; 1720: 464764, 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38458137

ABSTRACT

The limit of detection (LOD) is a crucial measure in analytical methods, representing the smallest amount of a substance that can be distinguished from background noise. In the realm of gas chromatography (GC), however, determining LOD can be quite subjective, leading to significant variability among researchers. In this study, we validate the Hubaux-Vos method, an International Standards Organization(ISO)-approved approach for determining LOD in gas concentration measurements, using a GC equipped with a discharge ionization detector (DID) and a dynamic dilution system. We employ a gas mixture certified reference material (CRM) of CO, CH4, and CO2 at various concentrations to generate calibration curves for each gas. Subsequently, we estimate the LODs for each gas using the Hubaux-Vos method. Surprisingly, our findings indicate a notable difference between the LODs calculated using the Hubaux-Vos method and those confirmed through experiments. This highlights the importance of critically examining the theoretical foundations of LOD determination. We strongly recommend researchers to scrutinize the principles guiding LOD determination. The method proposed in this study offers an effective way to rigorously validate theoretical approaches for estimating LODs in gas concentration measurements using GC.


Subject(s)
Limit of Detection , Chromatography, Gas/methods , Calibration , Reference Standards , Indicator Dilution Techniques
16.
J Chromatogr A ; 1720: 464798, 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38502990

ABSTRACT

We present a new chromatogram decomposition method for Gas Chromatography (GC) which represents a chromatogram as a sum of template functions inspired by the analytic solution of mass balance equation. The proposed method starts by approximating GC response of a single gas by these template functions. Consequently, it utilizes the temporal translation and dilation of this approximate response to approximate GC responses of other gases of interest. The results are demonstrated on lab data using calibration bottles containing mixtures of C1-C5. Correlation of the amplitudes of the decomposed responses and injected concentrations indicates linear calibration curves are sufficient to estimate C1-C5 concentrations. The performance of the method is demonstrated by a ratio test where a calibration bottle with C1 concentration 300 times larger than C2 and C3 concentrations is injected into GC.


Subject(s)
Gases , Calibration , Chromatography, Gas/methods , Gases/analysis
17.
J Chromatogr A ; 1721: 464823, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38547679

ABSTRACT

This paper reports a method for determining the oil absorption value of inorganic powder based on tracer-assisted headspace gas chromatographic (HS-GC) technique. The method was carried out by adding 25 µL droplet of toluene-Dioctyl Phthalate solution onto the surface of 1.0 g inorganic powder, then sealing the headspace vial and shaking it to make the powder spherical. The amount of toluene that not been adsorbed by inorganic powder was quantified using HS-GC with the optimal equilibrium temperature and time conditions of 100 °C and 7 min, respectively. A new mathematical model shows that the oil absorption value can be determined from the signal of toluene. The results show that the employed method has good precision (the relative standard deviation < 3.6 %) and accuracy (R2 = 0.993). This method is simple and accurate, and can be an reliable tool for testing the oil absorption value of inorganic powder sample.


Subject(s)
Toluene , Powders , Chromatography, Gas/methods , Temperature , Toluene/analysis
18.
J Chromatogr A ; 1718: 464718, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38335883

ABSTRACT

Chemical attribution is a vital tool to attribute chemicals or related materials to their origins in chemical forensics via various chemometric methods. Current progress related to organophosphorus nerve agents (OPNAs) has mainly focused on the attribution of chemical sources and synthetic pathways. It has not yet been applied in matching exposed biological samples to their sources. This work used chemical attribution to explore organic impurity profiles in biological samples exposed to various OPNAs. Chemical attribution was first used to identify the exposure source of biological samples based on the full-scan data via comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometer (GC × GC-TOFMS). Taking peak area as the only variable, it can quickly match exposed samples to their sources by applying unsupervised or supervised models, screen difference compounds via one-way ANOVA or t-tests, and then identify valuable impurities that can distinguish different types of exposed samples. To further obtain the impurity profile only applicable to a certain weapon' samples, the irrelevant components were removed via conventional methods. The findings showed there were 53 impurities that can promote distinguishing six groups of OPNA exposed samples, as well as 42 components that can be used as valuable impurities to distinguish class G and class V samples. These were all unique impurities that appear in a certain weapon' samples. The outcomes can be a reference for tracing the source for OPNA-exposed samples, which was beneficial to the further development in source matching of forensic samples. Moreover, the chemical attribution for impurity profiles in biological samples after weapons exposure may inspire research into the characteristics of impurity profile in biological samples as well as practical applications of chemical attribution for OPNA-exposed samples, that may expand potential biomarkers and break the limits of existing markers in the future.


Subject(s)
Nerve Agents , Mass Spectrometry , Chromatography, Gas/methods
19.
J Chromatogr A ; 1719: 464770, 2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38422708

ABSTRACT

A thermal desorber (TD) can be used in different ways to introduce samples in a gas chromatographic (GC) system. Besides its conventional use where the collected analytes are released from the sorbent in the sample tube, direct dynamic desorption (DDD) is an interesting option where a solid sample is put directly in the TD tube. However, since no sorbent is used for the sample, proper calibration is not straightforward. This issue was investigated in the present work using offline liquid calibration (OLC) and inline liquid calibration (ILC). Unexpectedly, ILC yielded a lower response than OLC. This could be related to the adsorption kinetics of the analytes and water on the cold trap of the TD. More insight was gained performing double injection ILC experiments with toluene as diluent for the analytes and injecting water before or after the toluene solution. This revealed a clear influence of the diluent. The influence of water was further explored applying two cold trap temperatures (4 °C and -30 °C). Inserting a LiCl trap in the TD tube to capture the water was found to be an effective solution for the problem. Finally, quantitative aspects of this approach were demonstrated.


Subject(s)
Cold Temperature , Water , Calibration , Chromatography, Gas/methods , Water/chemistry , Toluene
20.
J Chromatogr A ; 1717: 464711, 2024 Feb 22.
Article in English | MEDLINE | ID: mdl-38320433

ABSTRACT

The solvation parameter model uses five system independent descriptors to characterize compound properties defined as excess molar refraction, E, dipolarity/polarizability, S, hydrogen-bond acidity, A, hydrogen-bond basicity, B, and the gas-liquid partition constant at 25 °C on n-hexadecane, L, to model transfer properties in gas-condensed phase biphasic systems. The E descriptor for compounds liquid at 20 °C is available by calculation using a refractive index value while E for solid compounds at 20 °C and the S, A, B, and L descriptors are determined by experiment. As a single-technique approach, it is shown that with up to 20 retention factor measurements on four columns comprising a poly(siloxane) containing methyloctyl or dimethyldiphenylsiloxane monomers (SPB-Octyl or HP-5), a poly(siloxane) containing methyltrifluoropropylsiloxane monomers (Rtx-OPP or DB-210), a poly(siloxane) containing bis(cyanopropylsiloxane) monomers (HP-88 or SGE BPX-90), and a poly(ethylene glycol) stationary phase (DB-WAXetr or HP-INNOWAX) are suitable for assigning the S, A, and L descriptors. Using the descriptors in the updated WSU compound descriptor database as target values the average absolute error in the descriptor assignments for 52 varied compounds in the temperature range 60-140 °C was 0.072 for E, 0.016 for S, 0.008 for A, and 0.022 for L corresponding to 30 %, 3.5 %, and 0.6 % as a relative average absolute error for E, S, and L, respectively. For the higher temperature range of 160-240 °C and 34 varied compounds that are liquid at 20 °C the average absolute error for the S, A and L descriptors was 0.026, 0.020, and 0.031, respectively, with the largest relative average absolute error for S of 3.2 % (< 1 % for the L descriptor). For 35 varied compounds that are solid at 20 °C the relative absolute error for the E, S, A, and L descriptors in the higher temperature range was 0.068, 0.035, 0.020, and 0.020, respectively, with a relative average absolute error for E (6.5 %), S (3.5 %) and L (0.88 %). The S, A, and L descriptor can be accurately assigned on the four-column system over a wide temperature range. The E descriptor for solid compounds at 20 °C exhibits greater variability than desirable. The B descriptor cannot be assigned by the four-column system, which lack hydrogen-bond acid functional groups, and is only poorly assigned on the weak hydrogen-bond acid ionic liquid column SLB-IL100.


Subject(s)
Ionic Liquids , Siloxanes , Siloxanes/chemistry , Polyethylene Glycols , Chromatography, Gas/methods , Hydrogen
SELECTION OF CITATIONS
SEARCH DETAIL
...