Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 73
Filter
1.
Dermatology ; 238(1): 170-179, 2022.
Article in English | MEDLINE | ID: mdl-33827090

ABSTRACT

BACKGROUND: Auricular keloids belong to the most perplexing medical conditions, which have significant psychosocial impact on the patient's body image and quality of life. SUMMARY: The article is purposed to provide dermatologists and plastic surgeons with the best proven practice using intralesional cryosurgery for the treatment of the different auricular keloid types in order to obtain superior clinical results by minimizing the probability of recurrence. In the past 20 years, the authors have developed novel procedures in order to increase the effectiveness of intralesional cryosurgery on auricular keloids, including hydrodissection, warm gauze technique, and excision of dangling skin. Long-lasting clinical results with a low recurrence rate and a satisfactory aesthetic outcome are achieved with no deformation of the ear framework.


Subject(s)
Cryosurgery/standards , Ear Auricle/surgery , Injections, Intralesional/standards , Keloid/surgery , Practice Guidelines as Topic , Cryosurgery/methods , Humans , Injections, Intralesional/methods , Treatment Outcome
2.
Investig Clin Urol ; 62(4): 378-388, 2021 07.
Article in English | MEDLINE | ID: mdl-34190433

ABSTRACT

Thermal ablation has been established as an alternative treatment for renal cell carcinoma (RCC) in patients who are poor candidates for surgery. However, while American and European guidelines have been established for American and European patients, respectively, no ablation guidelines for Asian patients with RCCs have been established many years after the Asian Conference on Tumor Ablation (ACTA) had been held. Given that Western guidelines are difficult to apply to Asian patients due to differences in body habitus, economic status, and insurance systems, the current review sought to establish the first version of the ACTA guidelines for treating a RCC with thermal ablation.


Subject(s)
Ablation Techniques/standards , Carcinoma, Renal Cell/surgery , Kidney Neoplasms/surgery , Practice Guidelines as Topic , Carcinoma, Renal Cell/diagnostic imaging , Congresses as Topic , Cryosurgery/standards , Humans , Kidney Neoplasms/diagnostic imaging , Microwaves , Patient Selection , Preoperative Care , Radiofrequency Ablation/standards
3.
Arch. bronconeumol. (Ed. impr.) ; 56(12): 784-791, dic. 2020. tab, graf
Article in Spanish | IBECS | ID: ibc-199072

ABSTRACT

OBJETIVO: La evidencia disponible sobre la rentabilidad diagnóstica y la seguridad de la criobiopsia pleural (CB) está basada en una serie de estudios que presentan casuísticas limitadas y diferentes diseños. Un análisis agrupado de los mismos podría mejorarla y aportar una visión global de esta novedosa técnica. METODOLOGÍA: Revisión sistemática y metaanálisis de los estudios publicados en los que se incluían resultados sobre rendimiento y seguridad diagnóstica de la CB pleural comparados con la realizada con pinzas flexibles convencionales. Se evaluó la heterogeneidad del análisis determinando el índice I2 y la calidad de los estudios mediante la herramienta QUADAS-2. RESULTADOS: Para la evaluación final se incluyeron 7 trabajos con 356 pacientes. En el 55,6% el derrame pleural fue de etiología maligna, 61,1% de ellos cáncer de pulmón. La rentabilidad diagnóstica de la CB pleural fue del 95% (IC 95% 92-97) frente al 91% (IC 95% 87-94) con las pinzas flexibles convencionales (p = 0,019). Se describió sangrado leve en el 67% (IC 95% 62-72) de las CB frente al 85% (IC 95% 79-90) de las realizadas con pinzas flexibles convencionales (p < 0,001). El tamaño de las muestras de CB fue superior y el porcentaje de artefactos menor. No fue posible realizar un análisis agrupado en la evaluación de la detección de alteraciones moleculares. La heterogeneidad observada fue moderada-alta, aunque la calidad de los estudios fue aceptable. CONCLUSIONES: La CB pleural es una técnica segura y con elevada rentabilidad para el diagnóstico etiológico del derrame pleural, obteniéndose muestras de mayor tamaño con menos artefactos. Son necesarios más estudios sobre determinaciones moleculares


OBJECTIVE: Current evidence on the diagnostic yield and safety of pleural cryobiopsy (CB) is based on a series of heterogeneous studies with limited cohorts. A pooled analysis of these studies could improve the evidence and contribute to a better understanding of this new technique. METHODOLOGY: We performed a systematic review and meta-analysis of published studies that included data on the yield and diagnostic safety of pleural CB compared with procedures performed using conventional flexible forceps. The heterogeneity of the analysis was evaluated by determining the I2 index, while study quality was measured with the QUADAS-2 tool. RESULTS: Seven studies involving 356 patients were used for the final evaluation. In 55.6%, the etiology of the pleural effusion was malignant, 61.1% of which were lung cancer. The diagnostic yield of pleural CB was 95% (95% CI 92-97) vs. 91% (95% CI 87-94) with conventional flexible forceps (P = .019). Mild bleeding was reported in 67% of CB procedures (95% CI 62-72) compared with 85% of conventional flexible forceps procedures (95% CI 79-90) (P < .001). CB specimens were larger, and fewer artifacts were detected. A pooled analysis of the detection of molecular changes could not be performed. Heterogeneity was moderate to high, although the quality of the studies was acceptable. CONCLUSIONS: Pleural CB is a safe technique with a high yield for etiological diagnosis of pleural effusion, and larger specimens with fewer artifacts are obtained. Molecular determinations should be investigated in more deph


Subject(s)
Humans , Male , Female , Young Adult , Adult , Middle Aged , Aged , Cryosurgery/methods , Thoracoscopy/methods , Pleural Effusion/pathology , Biopsy/methods , Cryosurgery/standards , Thoracoscopy/standards , Biopsy/standards , Pleural Effusion/diagnosis , Surgical Instruments
4.
Arch Cardiovasc Dis ; 113(8-9): 492-502, 2020.
Article in English | MEDLINE | ID: mdl-32461091

ABSTRACT

The population of patients with congenital heart disease (CHD) is continuously increasing, and a significant proportion of these patients will experience arrhythmias because of the underlying congenital heart defect itself or as a consequence of interventional or surgical treatment. Arrhythmias are a leading cause of mortality, morbidity and impaired quality of life in adults with CHD. Arrhythmias may also occur in children with or without CHD. In light of the unique issues, challenges and considerations involved in managing arrhythmias in this growing, ageing and heterogeneous patient population and in children, it appears both timely and essential to critically appraise and synthesize optimal treatment strategies. The introduction of catheter ablation techniques has greatly improved the treatment of cardiac arrhythmias. However, catheter ablation in adults or children with CHD and in children without CHD is more technically demanding, potentially causing various complications, and thus requires a high level of expertise to maximize success rates and minimize complication rates. As French recommendations regarding required technical competence and equipment are lacking in this situation, the Working Group of Pacing and Electrophysiology of the French Society of Cardiology and the Affiliate Group of Paediatric and Adult Congenital Cardiology have decided to produce a common position paper compiled from expert opinions from cardiac electrophysiology and paediatric cardiology. The paper details the features of an interventional cardiac electrophysiology centre that are required for ablation procedures in adults with CHD and in children, the importance of being able to diagnose, monitor and manage complications associated with ablations in these patients and the supplemental hospital-based resources required, such as anaesthesia, surgical back-up, intensive care, haemodynamic assistance and imaging. Lastly, the need for quality evaluations and French registries of ablations in these populations is discussed. The purpose of this consensus statement is therefore to define optimal conditions for the delivery of invasive care regarding ablation of arrhythmias in adults with CHD and in children, and to provide expert and - when possible - evidence-based recommendations on best practice for catheter-based ablation procedures in these specific populations.


Subject(s)
Arrhythmias, Cardiac/surgery , Cardiac Surgical Procedures , Cardiologists/standards , Cardiology Service, Hospital/standards , Catheter Ablation/standards , Clinical Competence/standards , Cryosurgery/standards , Heart Defects, Congenital/surgery , Adolescent , Adult , Age Factors , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/mortality , Arrhythmias, Cardiac/physiopathology , Cardiac Surgical Procedures/adverse effects , Cardiac Surgical Procedures/mortality , Catheter Ablation/adverse effects , Catheter Ablation/mortality , Child , Child, Preschool , Consensus , Cryosurgery/adverse effects , Cryosurgery/mortality , Electrophysiologic Techniques, Cardiac/standards , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/mortality , Heart Defects, Congenital/physiopathology , Heart Rate , Humans , Infant , Infant, Newborn , Risk Factors , Survivors , Treatment Outcome , Young Adult
8.
Circ J ; 83(3): 548-555, 2019 02 25.
Article in English | MEDLINE | ID: mdl-30726801

ABSTRACT

BACKGROUND: Automated ablation lesion annotation with optimal settings for parameters including contact force (CF) and catheter stability may be effective for achieving durable pulmonary vein isolation. Methods and Results: We retrospectively examined 131 consecutive patients who underwent initial catheter ablation (CA) for paroxysmal atrial fibrillation (PAF) by automatic annotation system (VISITAG module)-guided radiofrequency CA (RFCA) (n=61) and 2nd-generation cryoballoon ablation (CBA) (n=70) in terms of safety and long-term efficacy. The automatic annotation criteria for the RFCA group were as follows: catheter stability range of motion ≤1.5 mm, duration ≥5 s, and CF ≥5 g. We ablated for >20 s with a force-time integral >150 gs at each site, before moving to the next site. Each interlesion distance was <6 mm. Procedural complications were more frequent in the CBA group (1.6% vs. 10.0%, P=0.034). Across a median follow-up of 2.98 years, 88.5% and 70.0% of patients in the RFCA and CBA groups, respectively, were free from recurrence (log-rank test, P=0.0039). There was also a significant difference in favor of RFCA with respect to repeat ablations (3.3% vs. 24.3%, log-rank test, P=0.0003). CONCLUSIONS: RF ablation guided by an automated algorithm that includes CF and catheter stability parameters showed better long-term outcomes than CBA in the treatment of patients with PAF without increasing complications.


Subject(s)
Atrial Fibrillation/therapy , Catheter Ablation/standards , Cryosurgery/standards , Aged , Algorithms , Atrial Fibrillation/complications , Automation , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cryosurgery/adverse effects , Cryosurgery/methods , Female , Humans , Male , Middle Aged , Recurrence , Retrospective Studies , Treatment Outcome
9.
Int J Cardiol ; 272: 130-136, 2018 Dec 01.
Article in English | MEDLINE | ID: mdl-30045822

ABSTRACT

BACKGROUND: The aim of this research was to evaluate whether the procedural data, the incidence of complications, and the long-term freedom from atrial fibrillation (AF) recurrences are influenced by center experience in a paroxysmal AF (PAF) population performing a first-time pulmonary vein isolation (PVI) by cryoballoon ablation (CBA). METHODS: A total of 860 patients underwent PVI by CBA. Center experience groups were predefined according to the quartiles of the distribution regarding the amount of performed procedures: 3.1%, 10.6%, 22.7% and 63.6% of patients were respectively followed in each group from 1st (less experienced) to 4th (more experienced) quartile of experience. RESULTS: In the entire population, median procedure and fluoroscopy time were 105 and 25 min, respectively. The median procedure time significantly decreased from 130 to 90 min (P < 0.001) as the center's experience increased. In 47 (5.5%) patients, a peri-procedural complication occurred. As the experience of centers increased, the acute intraprocedural PVI success rate increased (from 94.3% to 98.9%, P = 0.007), whereas there was a tendency towards a decreased incidence of peri-procedure complications (from 7.4% to 4.6%, P = 0.998). The mean 1-year freedom from AF recurrence probability was 78.3%, and the 18-month mean was 68.9% with no difference among the groups with different levels of experience. CONCLUSION: CBA is a safe and effective treatment for patients with PAF. Peri-procedural complications and procedural times were low in all the analyzed sub-groups, showing a decreasing trend in function of center expertise. The long-term freedom from AF recurrence was not influenced by the level of experience. (clinicaltrials.gov: NCT01007474).


Subject(s)
Atrial Fibrillation/surgery , Cardiology Service, Hospital/trends , Catheter Ablation/trends , Cryosurgery/trends , Perioperative Care/trends , Adult , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Cardiology Service, Hospital/standards , Catheter Ablation/standards , Clinical Competence/standards , Cryosurgery/standards , Data Analysis , Female , Humans , Male , Middle Aged , Perioperative Care/standards , Prospective Studies , Retrospective Studies , Time Factors , Treatment Outcome
10.
Int J Cardiol ; 270: 136-142, 2018 Nov 01.
Article in English | MEDLINE | ID: mdl-29929934

ABSTRACT

BACKGROUND: Unrecognized incomplete pulmonary vein isolation (PVI), as opposed to post-PVI pulmonary vein reconnection, may be responsible for clinical recurrences of atrial fibrillation (AF). To date, no data are available on the use of high-resolution mapping (HRM) during cryoballoon (CB) ablation for AF as the index procedure. The aims of this study were: - to assess the value of using a HRM system during CB ablation procedures in terms of ability in acutely detecting incomplete CB lesions; - to compare the 8-pole circular mapping catheter (CMC, Achieve) and the 64-pole mini-basket catheter (Orion) with respect to pulmonary vein (PV) signals detection at baseline and after CB ablation; - to characterize the extension of the lesion produced by CB ablation by means of high-density voltage mapping. METHODS: Consecutive patients with drug-resistant paroxysmal or early-persistent AF undergoing CB ablation as the index procedure, assisted by a HRM system, were retrospectively included in this study. RESULTS: A total of 33 patients (25 males; mean age: 59 ±â€¯18 years, 28 paroxysmal AF) were included. At baseline, CMC catheter revealed PV activity in 102 PVs (77%), while the Orion documented PV signals in all veins (100%). Failure of complete CB-PVI was more frequently revealed by atrial re-mapping with the Orion as compared to the Achieve catheter (24% vs 0%, p < 0.05). A repeat ablation was performed in 8 patients (24%). In 9% of cases, the Orion catheter detected far-field signals originating from the right atrium. Quantitative assessment of the created lesion revealed a significant reduction of the left atrial area having voltage >0.5 mV. A total of 29 patients (88%) remained free of symptomatic AF during a mean follow-up of 13.2 ±â€¯3.7 months. CONCLUSION: Atrial re-mapping after CB ablation by means of a HRM system improves the detection of areas of incomplete ablation, characterizes the extension of the cryo-ablated tissue and can identify abolishment of potential non-PVI related sources of AF.


Subject(s)
Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Catheter Ablation/standards , Cryosurgery/standards , Echocardiography, Transesophageal/standards , Adult , Aged , Catheter Ablation/methods , Cryosurgery/methods , Echocardiography/methods , Echocardiography/standards , Echocardiography, Transesophageal/methods , Female , Follow-Up Studies , Humans , Male , Middle Aged , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery
11.
Heart Rhythm ; 15(9): 1348-1355, 2018 09.
Article in English | MEDLINE | ID: mdl-29684571

ABSTRACT

Since the evaluation of the cryoballoon in the Sustained Treatment Of Paroxysmal Atrial Fibrillation trial, more than 350,000 patients with atrial fibrillation have been treated. Several studies have reported improved outcomes using the second-generation cryoballoon, and recent publications have evaluated modifications, refinements, and improvements in procedural techniques. Here, peer-reviewed articles published since the first cryoballoon best practices review were summarized against the technical practices of physicians with a high level of experience with the cryoballoon (average ≥6 years of experience in ≥900 cases). This summary includes a comprehensive literature review along with practical usage guidance from physicians using the cryoballoon to facilitate safe, efficient, and effective outcomes for patients with atrial fibrillation.


Subject(s)
Atrial Fibrillation/surgery , Cryosurgery/standards , Monitoring, Intraoperative/standards , Practice Guidelines as Topic , Disease-Free Survival , Humans , Recurrence
13.
Respiration ; 95(3): 188-200, 2018.
Article in English | MEDLINE | ID: mdl-29316560

ABSTRACT

Transbronchial cryobiopsies (TBCB) have recently been introduced as a promising and safer alternative to surgical lung biopsy in the diagnostic approach to diffuse parenchymal lung diseases (DPLD). Despite a substantial and expanding body of literature, the technique has not yet been standardized and its place in the diagnostic algorithm of DPLD remains to be defined. In part, this reflects concerns over the diagnostic yield and safety of the procedure, together with the rapid spread of the technique without competency and safety standards; furthermore, there is a substantial procedural variability among centers and interventional pulmonologists. We report this expert statement proposed during the third international conference on "Transbronchial Cryobiopsy in Diffuse Parenchymal Lung Disease" (Ravenna, October 27-28, 2016), which formulates evidence- and expert-based suggestions on the indications, contraindications, patient selection, and procedural aspects of the procedure. The following 5 domains were reviewed: (1) what is the role of TBCB in the diagnostic evaluation of DPLD: patient selection; (2) pathological considerations; (3) contraindications and safety considerations; (4) how should TBCB be performed and in what procedural environment; and (5) who should perform TBCB. Finally, the existence of white paper recommendations may also reassure local hospital credentialing committees tasked with endorsing an adoption of the technique.


Subject(s)
Bronchoscopy/methods , Cryosurgery/methods , Lung Diseases, Interstitial/diagnosis , Biopsy/standards , Bronchoscopy/standards , Cryosurgery/standards , Humans , Lung/pathology , Lung Diseases, Interstitial/pathology
16.
Int J Cardiol ; 253: 78-81, 2018 02 15.
Article in English | MEDLINE | ID: mdl-29196089

ABSTRACT

BACKGROUND: Second generation cryoballoon (CB-A) ablation is highly effective in achieving pulmonary vein (PV) isolation and freedom from atrial fibrillation (AF). However, the ideal freezing strategy is still under debate. Our objective was to investigate the efficacy and outcome between different freezing strategies used with the CB-A in a multicenter, matched population. METHODS: From a total cohort of 1018 patients having undergone CB-A ablation for drug-refractory AF, 673 patients with follow-up ≥6months were included and stratified according to the applied freezing strategy: bonus freeze (BF) versus single freeze (SF). Final population of 256 BF patients was compared with 256 propensity-score matched SF patients. RESULTS: BF strategy consisted of 3 different protocols: 3cycles of 180s; 2cycles of 240s; and cycles of 240s followed by 180s in 99/256 (39%); 42/256 (16%); and 115/256 (45%) patients, respectively. SF approach included cycles of 240s in 23/256 (9%), and 180s in 233/256 (91%) patients. Electrical isolation could be achieved in all PVs by both protocols, with shorter procedure and fluoroscopy times in the SF group (mean 106 vs 65min, and 18 vs 14min, respectively, P<0.001). Phrenic nerve palsy persisted after discharge in a total of 11 patients (2.1%): 4 (1.6%) in the BF group vs 7 (2.7%) in the SF group, P=0.5. AF-free survival was similar between the 2 groups during follow-up (mean 18±10months) (log rank, P=0.6). CONCLUSIONS: CB-A ablation showed equal efficacy and outcome between SF and BF strategy.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Cryosurgery/methods , Propensity Score , Aged , Atrial Fibrillation/diagnostic imaging , Catheter Ablation/standards , Cohort Studies , Cryosurgery/standards , Female , Follow-Up Studies , Humans , Male , Middle Aged
17.
Circ J ; 82(3): 659-665, 2018 02 23.
Article in English | MEDLINE | ID: mdl-29225299

ABSTRACT

BACKGROUND: Pulmonary vein isolation (PVI) using a cryoballoon (CB) is utilized for treating atrial fibrillation. This study aimed to assess the effect of the procedural characteristics of CB-based PVI (CB-PVI) on late PV reconnections.Methods and Results:A total of 389 consecutive patients underwent the CB-PVI as their index procedure; 45 consecutive patients underwent re-do procedures (184±87 days after the index CB-PVI). A total of 146 of 178 PVs (82%) remained isolated. The occlusion grade was evaluated in 171 PVs. Complete PV occlusion by the CB (grade 4) was obtained in 122 of 171 PVs (71%) during the index CB-PVI and the PVI status was maintained in 111 PVs (91%). Among the remaining 49 CB-PVIs without complete PV occlusion (grades 1-3), 20 PVs (41%) had late PV reconnections despite successful PVI during the index CB-PVI. A "pull-down maneuver" was performed in 20 PVs because of leakage of blood at the inferior aspect of the PVs, and all those PVs with a successful pull-down maneuver maintained their PVI status. A multivariate analysis demonstrated that the presence of complete PV occlusion was the only independent predictor for persistence of PVI. CONCLUSIONS: The occlusion grade was a reliable predictor of the long-term durability of PVI.


Subject(s)
Atrial Fibrillation/therapy , Balloon Occlusion/standards , Catheter Ablation/methods , Cryosurgery/methods , Pulmonary Veins/physiopathology , Aged , Atrial Fibrillation/surgery , Cryosurgery/standards , Female , Humans , Male , Middle Aged , Pulmonary Veins/surgery , Salvage Therapy/methods , Treatment Outcome
18.
J Endourol ; 31(11): 1117-1122, 2017 11.
Article in English | MEDLINE | ID: mdl-28830229

ABSTRACT

BACKGROUND: Small series have reported that cryoablation (CA) is a safe and feasible minimally invasive nephron-sparing alternative for the treatment of renal angiomyolipomas (renal AMLs). The aim of the present study was to investigate the safety and efficacy of CA in patients with renal AML. MATERIALS AND METHODS: A retrospective review of 19 renal AML lesions treated with CA at Aarhus University Hospital, Denmark, over a 5-year period. RESULTS: The treatment was performed as laparoscopy-assisted CA on 7 lesions, and in the remaining 12 lesions CA was performed as a percutaneous ultrasound-guided CA. The mean patient age was 46 years [interquartile range (IQR) 30] and the mean tumor volume was 50.1 cm3 (IQR 53.3). In all cases, the procedure was effectively conducted with no conversion to open surgery, and no major complications were experienced. The mean follow-up time was 25 months (IQR 13). Mean maximum tumor volume was reduced from 50.1 cm3 (IQR 53.3) to 12.2 cm3 (IQR 14.1), p = 0.05. No patients presented with retroperitoneal hemorrhage or recurrence during follow-up. CONCLUSION: Treating renal AMLs with CA appears to be a safe and effective nephron-sparing approach and could be a valuable alternative to other treatment modalities. The low complication rate, absence of retreatment and a good preservation of renal function might allow treatment of even subclinical renal AMLs to minimize the risk of potentially life-threatening hemorrhage.


Subject(s)
Angiomyolipoma/surgery , Cryosurgery/standards , Kidney Neoplasms/surgery , Neoplasm Recurrence, Local/surgery , Adult , Angiomyolipoma/diagnostic imaging , Denmark , Female , Humans , Kidney Neoplasms/diagnostic imaging , Laparoscopy , Male , Middle Aged , Neoplasm Recurrence, Local/diagnostic imaging , Patient Safety , Postoperative Complications , Retrospective Studies
19.
J Cardiovasc Electrophysiol ; 28(8): 870-875, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28497857

ABSTRACT

BACKGROUND: Achieve catheters are cryoballoon guidewires that enable pulmonary vein (PV) potential mapping. The single catheter approach in conjunction with the Achieve catheter is currently standard practice in second-generation cryoballoon ablation, yet circumferential mapping catheters are the gold standard for evaluating PV isolation (PVI). The study sought to validate the ostial PVI verified by an Achieve catheter alone. METHODS: One hundred fifty-one paroxysmal atrial fibrillation patients undergoing PVI using exclusively 28-mm second-generation cryoballoons were enrolled. PV recordings were analyzed during (real-time recordings) and after cryoballoon applications with 20-mm Achieve mapping catheters, and subsequently validated by 20-mm conventional circumferential mapping catheters. RESULTS: Out of 596 PVs, 576 (96.6%) were isolated using cryoballoons, and 20 required touch-up ablation. PVI was verified during cryoballoon applications with real-time monitoring in 299, and after applications in 280 PVs by Achieve catheters alone. The time-to-isolation was 27.2 ± 22.0 seconds. Validation with standard circumferential mapping catheters confirmed ostial PVIs in 296 of 299 (99.0%) PVs that real-time PVI was obtained during applications, and in 242 of 280 (86.5%) PVs that PV activities were not visible during applications and PVI was verified after the applications. The accuracy of ostial PVIs with Achieve catheters in PVs without obtaining real-time PV recordings was 40/47 (85.1%), 58/65 (89.2%), 77/79 (97.5%), 61/81 (75.3%), and 6/8 (75.0%) in left superior, left inferior, right superior, right inferior, and left common PVs, respectively. CONCLUSIONS: In second-generation 28-mm cryoballoon ablation, verification of ostial PVIs using Achieve mapping catheters alone might not be sufficient to accurately confirm an ostial PVI when real-time PVI was not obtained.


Subject(s)
Atrial Fibrillation/surgery , Body Surface Potential Mapping/methods , Cardiac Catheterization/methods , Catheter Ablation/methods , Cryosurgery/methods , Pulmonary Veins/surgery , Aged , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/physiopathology , Body Surface Potential Mapping/standards , Cardiac Catheterization/standards , Catheter Ablation/standards , Cryosurgery/standards , Female , Follow-Up Studies , Heart Conduction System/physiology , Humans , Male , Middle Aged , Pulmonary Veins/diagnostic imaging
20.
Aust Fam Physician ; 46(5): 270-274, 2017.
Article in English | MEDLINE | ID: mdl-28472571

ABSTRACT

BACKGROUND: Cryosurgery is an effective, simple and inexpensive treatment used extensively in general practice and dermatology. It is used most commonly for actinic keratoses and warts; however, a large number of benign, premalignant and malignant skin diseases can also be treated. OBJECTIVE: The objective of this article is to help readers improve their cryosurgery technique. DISCUSSION: Application of the cryogenic agent (most commonly liquid nitrogen) to the skin induces rapid freezing followed by slow thawing. This produces cell injury, vascular stasis and occlusion, and inflammation. The quantity of cryogen delivered onto the skin (dose), technique, duration of thawing and amount of surrounding tissue frozen are dependent on the body region and type of lesion. If clinical diagnosis is not possible, either a skin biopsy or referral to a dermatologist is recommended. We strongly discourage blind treatment of undiagnosed skin lesions.


Subject(s)
Cryosurgery/methods , Cryosurgery/standards , Skin Diseases/therapy , Contraindications , Humans , Nitrogen/pharmacokinetics , Nitrogen/therapeutic use , Skin/injuries , Skin/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...