Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 111
Filter
1.
Forensic Sci Int ; 308: 110166, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32004996

ABSTRACT

Conducting research in the field of forensic sciences with methodologies that simulate situations found in the day-to-day practice of a given field of expertise is relevant insofar as this approach can produce results that are as close as possible to reality. In this context, the present study provided situations based on burial in a mangrove environment to estimate the changes in the mechanical properties (Knoop microhardness, roughness and color) of dental restorations utilizing silver amalgam, composite resin and glass ionomer cement over the time of burial. The silver amalgam showed a significant increase in surface roughness and a reduction in Knoop microhardness. Composite resin showed a statistically significant increase in color variation, and the glass ionomer cement showed significant increases in color variation and Knoop microhardness. These results allowed us to conclude that teeth restored with silver amalgam, composite resin and glass ionomer cement submitted to burial in mangrove environments produce different changes in surface roughness, Knoop microhardness and color properties depending on the time of burial to which the victims were submitted. These proprieties could help the forensic sciences to estimate time intervals for burial in mangrove environments.


Subject(s)
Composite Resins/analysis , Dental Amalgam/analysis , Dental Restoration, Permanent/methods , Glass Ionomer Cements/analysis , Incisor/chemistry , Surface Properties , Animals , Brazil , Burial , Cattle , Color , Forensic Dentistry , Postmortem Changes , Wetlands
2.
Appl Spectrosc ; 71(4): 659-669, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28103053

ABSTRACT

In this work the diffusion of mercury and other elements from amalgam tooth restorations through the surrounding dental tissue (dentin) was evaluated using femtosecond laser-induced breakdown spectroscopy (fs-LIBS). To achieve this, seven deciduous and eight permanent extracted human molar teeth with occlusal amalgam restorations were half-sectioned and analyzed using pulses from a femtosecond laser. The measurements were performed from the amalgam restoration along the amalgam/dentin interface to the apical direction. It was possible to observe the presence of metallic elements (silver, mercury, copper and tin) emission lines, as well as dental constituent ones, providing fingerprints of each material and comparable data for checking the consistence of the results. It was also shown that the elements penetration depth values in each tooth are usually similar and consistent, for both deciduous and permanent teeth, indicating that all the metals diffuse into the dentin by the same mechanism. We propose that this diffusion mechanism is mainly through liquid dragging inside the dentin tubules. The mercury diffused further in permanent teeth than in deciduous teeth, probably due to the longer diffusion times due to the age of the restorations. It was possible to conclude that the proposed femtosecond-LIBS system can detect the presence of metals in the dental tissue, among the tooth constituent elements, and map the distribution of endogenous and exogenous chemical elements, with a spatial resolution that can be brought under 100 µm.


Subject(s)
Dental Amalgam/analysis , Mercury/analysis , Molar/chemistry , Spectrum Analysis/methods , Dental Amalgam/chemistry , Diffusion , Humans , Mercury/metabolism
3.
Belo Horizonte; s.n; 2016. 68 p.
Thesis in English, Portuguese | BBO - Dentistry | ID: biblio-947828

ABSTRACT

A Lesão liquenóide oral associada ao amálgama (LLOAA) é uma lesão incomum de patogênese ainda incerta. A lesão apresenta características clínicas e histopatológicas semelhantes ao líquen plano bucal (LPB), que é considerada uma lesão com potencial de transformação maligna. Pesquisas moleculares a fim de aprimorar os conhecimentos sobre a patogênese e o comportamento clínico de LLOAA ainda são escassas. O objetivo do estudo foi investigar a perda de heterozigosidade (loss of heterozygosity ­ LOH) em amostras de LLOAA, LPB e mucosa bucal normal (MBN) em regiões cromossômicas 9p22, 11q13.4 e 17p13.1 e avaliar o índice de proliferação celular das mesmas amostras, buscando uma associação entre o índice de proliferação celular e LOH. Foram selecionadas 9 amostras de LLOAA, 10 de LPB e 8 de MBN, pareadas por sexo e idade. A LOH nas regiões cromossômicas 9p22, 11q13.4 e 17p13.1 foi avaliada por meio dos marcadores microssatélites polimórficos D9S157, D9S162, D9S171, D11S1369, TP53, AFM238WF2. O índice de proliferação celular foi avaliado pela expressão imuno-histoquímica da proteína Ki-67 (MIB-1) em 8 amostras de LLOAA, 10 de LPB e 8 de MBN. Amostras de LLOAA exibiram LOH em 3 dos 6 marcadores (AFM238WF2, D9S157 e D11S1369), de LPB exibiram LOH em 2 destes marcadores (AFM238WF2, D9S157) enquanto que amostras de MBN não apresentaram LOH. A perda alélica foi mais frequente para os marcadores AFM238WF2 (17p13.1, 21%) e D9S157 (9p22, 17,64%) e a média da frequência de perda alélica na amostras de LLOAA foi de 26,6% enquanto que nas amostras de LPB foi de 7,5%. A imuno-histoquímica apresentou positividade nuclear nas células variando entre 0,29% a 28% e não houve associação entre o índice de proliferação celular e LOH em LLOAA e LPB (p>0,05). Este estudo demonstrou que LLOAA, semelhante ao LPB, apresentou LOH nas regiões cromossômicas 9p22, 11q13.4 e 17p13.1, independentemente da taxa de proliferação celular. Apesar de não ter sido encontrada tal associação, LOH ocorre em LLOAA e pode estar envolvida na patogênese desta lesão


The Amalgam-associated oral lichenoid lesion (AAOLL) is an infrequent disease of uncertain pathogenesis. The lesion shows clinical and histopathological features similar to oral lichen planus (OLP), which is considered a lesion with malignant transformation potential. Molecular researches in order to improve knowledge of the pathogenesis and clinical behavior of AAOLL are still scarce. The purpose of the current study was to evaluate the loss of heterozygosity - LOH in AAOLL, in OLP, and in normal oral mucosa (NOM) using polymorphic microsatellite markers at chromosome regions 9p22, 11q13.4 and 17p13.1, located around important tumor suppressor genes and to evaluate the immunohistochemical expression of Ki67 protein in the same samples. The sample comprised 09 AAOLLs, 10 OLPs and 8 NOMs matched by patients' gender and age. The LOH at chromosome regions 9p22, 11q13.4 and 17p13.1 was evaluated by microsatellite polymorphic markers D9S157, D9S162, D9S171, D11S1369, TP53, AFM238WF2. Cell proliferation was assessed by immunohistochemical expression of Ki-67 (MIB-1) in eight AAOLL, ten OLP and eight NOM. AAOLL exhibited LOH at 3 of 6 LOH markers (AFM238WF2, D9S157 AND D11S1369), while OLP demonstrated LOH at two of these markers (AFM238WF2, D9S157) while NOM showed no LOH. The allelic loss were most frequently in marker AFM238WF2 (17p13.1, 21%) and D9S157 (9p22, 17,64%). The mean fractional allelic loss of AAOLL was 26,6% whereas mean fractional allelic loss of OLP was 7,5%. Immunohistochemistry revealed nuclear positivity ranging from 0,29% to 28% of the cells and there was no association between cell proliferation and LOH in LLOAA e LPB (p>0,05). Our study shows that AAOLL, similar to OLP, exhibits LOH, irrespective of cell proliferation index. Despite the lack of association between LOH and cell proliferation we can assume that LOH occurs in AAOLL and it should be considered in the pathogenesis of this lesion


Subject(s)
Humans , Male , Female , Dental Amalgam/analysis , Lichen Planus, Oral/diagnosis , Loss of Heterozygosity , Mouth Mucosa/abnormalities , Mouth Neoplasms/classification , Mouth Neoplasms/diagnosis , Cell Proliferation/physiology
4.
Rev. Soc. Odontol. La Plata ; 25(51): 25-31, dic.2015. ilus
Article in Spanish | LILACS | ID: lil-795813

ABSTRACT

El propósito del trabajo será analizar comparativamente los diversos efectos que producen sobre las restauraciones dentales agentes blanqueadores.El objetivo será valorar los cambios que experimentan en la superficie los materiales de restauración, sometidos a la acción de un agente blanqueador. La metodología utilizada será visualización microscópica electrónica de barrido ambiental. Los resultados obtenidos tendrán transferencia relevante a Insti-tuciones formadoras de recursos humanos en Salud Bucal, al campo profesional odontológico y a empresas o fabricantes para el mejoramiento de su producto...


Subject(s)
Dental Amalgam/analysis , Tooth Bleaching/adverse effects , Glass Ionomer Cements/analysis , Hydrogen Peroxide/adverse effects , Composite Resins/analysis , Tooth Bleaching/classification , Bicuspid/ultrastructure , Materials Testing , Microscopy, Electron, Scanning/methods , Molar/ultrastructure , Dental Restoration, Permanent/instrumentation , Surface Properties , Tooth, Nonvital
5.
J Contemp Dent Pract ; 15(2): 165-8, 2014 Mar 01.
Article in English | MEDLINE | ID: mdl-25095837

ABSTRACT

AIM: The aim of this study was to evaluate mercury levels in wastewater and in patients during the removal of dental amalgam restorations. MATERIALS AND METHODS: To test for mercury levels, patients were tested before and after amalgam restoration removal. To test for mercury emissions, samples of constant volume of wastewater from high-speed drills were collected before and during amalgam restoration removal. RESULTS: Although the systemic mercury levels were lower than the limit of biological tolerance, all patients had increased levels after dental restorations. All samples of wastewater had increased mercury levels too. CONCLUSION: The urinary levels of mercury increased with dental amalgam removal using a high-speed drill. During the process of amalgam removal, water used for cooling the dental drill was contaminated with mercury. CLINICAL SIGNIFICANCE: The mercury released by the physical action of the drill, the replacement material and especially the final destination of the amalgam waste can increase contamination levels that can be a risk for human and environment health.


Subject(s)
Dental Amalgam , Dental Debonding , Dental Restoration, Permanent , Dental Waste/analysis , Mercury/analysis , Water/analysis , Adult , Body Burden , Dental Amalgam/analysis , Dental Debonding/instrumentation , Dental High-Speed Equipment , Dental Restoration, Permanent/instrumentation , Female , Hazardous Waste/analysis , Humans , Male , Mercury/urine , Young Adult
6.
J. Health Sci. Inst ; 30(3)jul.-set. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-670562

ABSTRACT

Objetivo - Verificar o uso e aplicação de um medidor portátil de análise quantitativa de vapores de mercúrio. Os locais de escolha foram a Clínica Odontológica e o Laboratório Multidisciplinar 104 da Faculdade de Odontologia das Faculdades São José, Rio de Janeiro-RJ, Brasil. Nesses locais ocorrem muitas atividades restauradoras com amálgama dentário realizadas por alunos, tornando-se importante a verificação da possível contaminação por vapores tóxicos de mercúrio existente naqueles ambientes. Métodos - Para a medição foi utilizado um aparelho analisador Zeeman quantitativo avançado de mercúrio portátil da marca Lumex modelo RA-915+. O aparelho foi acionado no final da tubulação de rejeito das cuspideiras das cadeiras A, C, D, E, F, J, H e ar do amalgamador recém-acionado. No Laboratório Multidisciplinar 104 foram inspecionados: ar/ambiente e em manequim usado para treino. Foram feitas também inspeções no ar em ambiente onde não se usa amálgama a fim de verificação do teor zero. Resultados - Na Clínica Odontológica as cadeiras C, E, F e H foram as que apresentaram os maiores índices de contaminação, dentre estas a cadeira H destacou-se com 26.140 ngHg/m³. Os locais onde não se manipula amálgama o índice foi 0ngHg/m³. Conclusões - Os altos índices de vapores de mercúrio nas tubulações das cadeiras indicam que as medidas seguras de descartes de resíduos não estão sendo realizadas adequadamente. Este sistema de medição quantitativa direta mostrou-se simples no manuseio e extremamente útil no monitoramento de ambientes sujeitos à contaminação por vapores tóxicos de mercúrio.


Objective - To examine the use and application of a portable meter for quantitative analysis of mercury vapors. The places of choice were the Dental Clinic and Laboratory Training 104 of the School of Dentistry of São José College, Rio de Janeiro-RJ, Brazil. In these places many activities occur restorative dental amalgam made by students, making it important to check the possible contamination by toxics vapors mercury existing in those environments. Methods - For the measurement we used an advanced device analyzer Zeeman quantitative mercury brand laptop Lumex model RA-915+. The device was fired at the end of the waste pipe spitting chairs A, C, D, E, F, J, H and air amalgamator newly activated. In the Laboratory Training 104 were inspected: air/environment and dummy used for training. Inspections were performed also on air at ambient where amalgam is not used to check content zero. Results - In Dental Clinic chairs C, E, F and H were the ones that showed the highest levels of contamination, among these the seat H stood out with 26.140 ngHg / m³. Places where no handles amalgam index was 0ngHg/m³. Conclusions - The high levels of mercury vapor in the pipes of the chairs indicate that measures of safe waste disposal are not being carried out properly. This direct quantitative measurement system proved simple in handling and extremely useful in monitoring environments subject to contamination by toxic mercury vapors.


Subject(s)
Dental Amalgam/analysis , Dental Amalgam/supply & distribution , Dental Amalgam/chemical synthesis , Dental Amalgam , Evaluation Studies as Topic/analysis , Evaluation Studies as Topic/statistics & numerical data , Evaluation Studies as Topic/methods , Mercury/analysis , Mercury/adverse effects , Mercury/pharmacology , Mercury/toxicity
7.
Bull Environ Contam Toxicol ; 88(5): 797-801, 2012 May.
Article in English | MEDLINE | ID: mdl-22395198

ABSTRACT

The objective of this work was to estimate the quantity of mercury residue present in dental amalgam that is generated and discarded in the city of Manaus (Amazon-Brazil). For this purpose, the locations of amalgam usage (10 public and 31 private dental clinics), the method by which the residue is discarded (14 clinics improper disposal), and the analysis of total mercury in the sediment of the controlled landfill (2.68-3 µgHg/g), were described. It was concluded that: there are dental clinics in the city that discard mercury residue into the common waste disposal system, which contravenes health safety standards.


Subject(s)
Dental Amalgam/analysis , Dental Waste/analysis , Medical Waste Disposal/methods , Mercury/analysis , Silver/analysis , Brazil , Dental Clinics/statistics & numerical data , Dental Waste/statistics & numerical data , Developed Countries , Environmental Monitoring , Humans , Medical Waste Disposal/statistics & numerical data
8.
RGO (Porto Alegre) ; 59(1): 41-44, jan.-mar. 2011.
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-588576

ABSTRACT

OBJETIVO: Verificar macroscopicamente as alterações sofridas por restaurações de amálgama em cápsulas e convencional, quando submetidos a temperaturas elevadas e destacar a importância dessas alterações nos processos de identificação humana. MÉTODOS: Foram analisados 48 dentes humanos, oriundos do cemitério São Gonçalo da Prefeitura Municipal de Cuiabá, Mato Grosso, que passaram por tratamento restaurador com amálgama dental e submetidos à elevadas temperaturas que variaram de 100ºC a 1200ºC para avaliação das alterações sofridas por esse material. RESULTADOS: As restaurações em amálgama convencional sofrem escurecimento a partir dos 300ºC, apresentando-se pulverulentas a partir dos 300ºC e entrando em processo de calcinação a partir dos 800ºC. Já a restauração com amálgama em cápsula sofreu escurecimento a partir dos 400ºC, tornando-se novamente prateada a 1200ºC, apresentando-se pulverulenta a partir dos 500ºC e calcinada a 1200ºC. CONCLUSÃO: As restaurações de amálgama apresentaram alterações em sua coloração (escurecimento) e em sua estrutura (pulverização e calcinação), que poderão servir de comparação com registros odontológicos de eventuais vítimas de desastres, nos trabalhos de identificação humana, onde os corpos tiverem sofrido a ação do fogo.


OBJECTIVE: This study verified the macroscopic changes that occur in capsulated and conventional restorations submitted to high temperatures and discussed the importance of these changes for fire victim identification processes. METHODS: A total of 48 human teeth were analyzed. They were obtained from the municipal graveyard São Gonçalo in Cuiabá, Mato Grosso, filled with dental amalgam and subjected to high temperatures ranging from 100ºC to 1200ºC to study the changes that occur in this material. RESULTS: Conventional amalgam restorations darkened and pulverized at 300ºC and roasting began at 800ºC. Meanwhile, capsulated amalgam darkened at 400ºC, pulverized at 500ºC and became silvery again at 1200ºC, when roasting began. CONCLUSION: Heat darkened the color, pulverized the structure and roasted amalgam restorations. This may help in the comparison of dental records of fire victims.


Subject(s)
Humans , Dental Amalgam/analysis , Forensic Anthropology , Calorimetry
9.
J. Health Sci. Inst ; 27(3)jul.-set. 2009. tab
Article in Portuguese | LILACS | ID: lil-550807

ABSTRACT

Introdução - A perfuração na região de furca é considerada um dos mais sérios fatores para o fracasso do tratamento endodôntico. Baseado nisso, o objetivo do estudo foi comparar a capacidade seladora do amálgama de prata e do MTA em perfurações de furca. Materiais e Métodos - Foram utilizados 24 molares superiores e inferiores, que após cirurgia de acesso, tiveram uma perfuração na região da furca feita com broca carbide nº 3 em alta rotação. As paredes externas foram impermeabilizadas com cianoacrilato de etila e os espécimes foram divididos em dois grupos experimentais, com 10 elementos cada, onde G1 foi vedado com MTA e G2 com amálgama de prata. Os dentes foram, então, imersos em corante azul de metileno por 24 horas e, posteriormente, seccionados longitudinalmente para mensuração das infiltrações, classificadas em 3 níveis. Resultados - Sete elementos do Grupo 1 não apresentaram infiltração de corante e 3 tiveram pequena infiltração. Já no Grupo 2, apenas 2 dentes não demonstraram infiltração enquanto que o restante ficou igualmente dividido entre infiltração pequena e severa. O teste de Kruskal-Wallis revelou diferenças significantes entre os grupos experimentais. Conclusão - É lícito concluir que o MTA apresenta capacidade superior para o vedamento das perfurações de furca do que o amálgama de prata.


Introduction - Furcal perforation is considered one of the most serious factors for the endodontic treatment failure. Based on this, the aim of this study was to compare the marginal sealing promoted by the amalgam and MTA in the furcal perforations. Materials and Methods - In present study were used 24 upper and lower molars were used. After the endodontic access, a perforation in the furcal area was made with a carbide drill #3. The external teeth walls received two layers of ethyl cyanoacrylate and then, the specimens were divided in two experimental groups, with 10 teeth each, where G1 was sealed with MTA and G2 with amalgam. The teeth were immersed in methylene blue dye for 24 hours and after that, split longitudinally to measure the leakage index, classified in three levels. Results - Seven samples of Group 1 did not show dye leakage and two showed small leakeage. In Group 2, only 2 specimens did not have any sign of dye leakage whereas the rest of them was divided in small and severe leakage. Kruskal-Wallis test showed significant differences between experimental groups. Conclusion - It was conclude that MTA promoted a better seal for furcal perforations than the amalgam.


Subject(s)
Dental Amalgam/analysis , Endodontics/instrumentation , Dental Leakage/diagnosis , Root Canal Filling Materials/analysis
10.
Toxicol Ind Health ; 23(2): 103-13, 2007 Mar.
Article in English | MEDLINE | ID: mdl-18203562

ABSTRACT

Mercury (Hg) is widely used in the dental working environment, exposing dental practitioners and assistants to potentially toxic Hg vapors. Concentrations of Hg in vapor and in particulate matter (PM10) were measured in the Dental Simulation Laboratory (DSL) and in the Dental Clinic (DC) at the School of Dentistry, University of Puerto Rico. PM10 samples were collected over a 36-h period and Hg vapor was collected for eight-hour periods. PM10 mass was determined gravimetically and Hg (bound to PM10 and vapor) was extracted and analyzed by atomic absorption. Indoor levels of PM10 in the DSL ranged from 9.2 to 41.6 microg/m3 and 35.0 to 68.2 microg/m3 in the DC. Levels of particle-bound Hg ranged from 0.1 to 1.2 microg/m3 and in vapor 1.1 to 3.3mg/m3 at the DSL; the DC levels ranged from <0.01 to 0.2 microg/m3 for particle bound Hg and 13.6 to 102.7 microg/m3 in vapor. PM10 concentrations were below Indoor Air Quality suggested limits for total dust (100 microg/m3). Levels of mercury bound to PM10 were low; however, mercury vapor was several times higher than the suggested OSHA (permissible exposure limit--100 microg/m3) in the DSL.


Subject(s)
Air Pollutants, Occupational/analysis , Dental Clinics , Environmental Monitoring/methods , Mercury/analysis , Occupational Exposure/analysis , Particulate Matter/analysis , Schools, Dental , Dental Amalgam/analysis , Humans , Pilot Projects , Puerto Rico , Volatilization
11.
Rev. bras. odontol ; 63(1/2): 123-125, 2006. tab
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-438474

ABSTRACT

O objetivo foi avaliar a qualidade microbiológica de materiais odontológicos (Vitrebond- 3M, Z100 - 3M, Single Bond - 3M e Permite C - SDI) antes, durante e após serem usados. As amostras foram colocadas em Erlemayer contendo Calet (DIFCO) e incubadas a 32-35°C por 20 dias. Quando turvado, o meio foi semeado em MHa (Merck) e Alet (DIFCO), e incubado. Identificados os morfotipos, as bactérias foram transferidas para Agar Nutriente (Merck), para identificação. Verificou-se que os materiais testados vieram de fábrica sem contaminação, havendo pouca probabilidade de contaminação cruzada pelo uso desses materiais


Subject(s)
Dentin-Bonding Agents/analysis , Dental Amalgam/analysis , Environmental Pollution , Glass Ionomer Cements/analysis , Infection Control, Dental , Dental Materials/analysis , Composite Resins/analysis
13.
Arq. odontol ; 41(1): 005-19, 2005. ilus
Article in Portuguese | LILACS, BBO - Dentistry | ID: biblio-849923

ABSTRACT

A variação no julgamento clínico das restaurações é um problema que afeta a maioria dos profissionais, resultando em prejuízos biológico e financeiro. Este trabalho teve como objetivo avaliar um programa de treinamento participativo para padronização de critérios na avaliação de restaurações de amálgama. Um grupo de cinco professores de Clínica Integrada de um Curso de Odontologia avaliou 28 dentes permanentes extraídos contendo restaurações de amálgama, antes e após a participação num programa de treinamento. Foram utilizados os exames visual e radiográfico e a avaliação final foi agrupada em quatro categorias de julgamento: satisfatória, necessita de substituição total, necessita de substituição parcial ou necessita de acabamento e polimento, com justificativa da opção feita. O programa de treinamento foi constituído de quatro sessões quinzenais: fundamentação teórica, calibração com slides, calibração com dentes extraídos e elaboração da tabela de critérios. Os resultados mostraram um aumento após o treinamento tanto no nível de concordância inter-examinadores (índice kappa) como no nível de acurária em relação ao padrão ouro (validade), e estes se mantiveram, mesmo decorridos cinco meses após o término do programa de trinamento. Estes resultados sinalizam a possibilidade da utilização desta metodologia para outras calibrações e outros grupos


Subject(s)
Dental Amalgam/analysis , Dental Amalgam/therapeutic use , Dental Restoration, Permanent/adverse effects , Judgment
14.
Cpd dentistry ; 5(3): 90-94, 2004.
Article in English | MedCarib | ID: med-17570

ABSTRACT

Purpose: The purpose of this study was to assess the shear bond strength of amalgam when bonded to dentine with various cements. Materials and Methods: Eighty human molars were divided into five groups and ground dentine surfaces treated, with one of five cements (Fuji I, Vitrebond, Rely X, Fuji II and Panavia F). Spherical amalgam (Tytin) was condensed onto the unset cement and shear bond strengths were measured after one week. Results: The mean shear bond strength of Panavia F (25.3 MPa) was significantly higher compared with Fuji I (16.8 MPa), Fuji II (10.3 MPa) and Vitrebond (5.1 MPa) however there was no significant difference with Rely X (19.0 MPa). Conclusion: The combination of a resin modified glass ionomer luting cement with a spherical alloy may enhance bonding of amalgam to dentine.


Subject(s)
Humans , In Vitro Techniques , Dental Amalgam/analysis , Glass Ionomer Cements/analysis , Glass Ionomer Cements , Shear Strength
15.
Rev. paul. odontol ; 25(5): 20-23, set.-out. 2003. tab
Article in Portuguese | LILACS, BBO - Dentistry | ID: biblio-872609

ABSTRACT

Análise in vitro da rugosidade superficial de diferentes ligas para amálgama, em função da técnica e período de polimento. utilizou-se três ligas para amálgama: M1 - Velvalloy, M2 - Permite e M3 - Dispersalloy, duas técnicas de polimento: T1 - multilaminadas + borrachas abrasivas + pedra pomes com água e T2 - borrachas abrasivas + pedra pomes com água em dois momentos: P1 - imediato (após 15 minutos da condensaçào) e P2 - após 24 horas. Para cada condição experimental foram confeccionados 5 corpos-de-prova, utilizando-se uma matriz de teflon com um orifício central de 5mm de diâmetro de 2mm de altura, sendo realizadas quatro leituras em cada um deles num rugosímetro (Prazis). os dados foram submetidos à análise de variância (pú0,05) e teste de Tukey. As médias obtidas em micrômetros foram: para o material - M1: 0,93; M2: 0,75 e M3: 0,81; para a técnica - T1: 0,99 e T2: 0,67, e para o momento de polimento - P1: 1,05 e P2: 0,61. Concluiu-se que é necessário esperar 24 horas para realizar o polimento, sendo mais indicado realizá-lo com borrachas abrasivas e pedar pomes com água. As ligas ricas em cobre apresentaram melhores resultados que a liga convencional


Subject(s)
Dental Amalgam/analysis , Dental Polishing/methods , Dental Materials/analysis
19.
Pesqui. odontol. bras ; Pesqui. odontol. bras;14(4): 345-50, out.-dez. 2000. tab, graf
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-281448

ABSTRACT

Os autores estudaram o efeito de quatro diferentes técnicas de polimento de restauraçöes de amálgama feitas em laboratório com duas ligas convencionais e três ligas com alto teor de cobre, sendo o polimento realizado no tempo de 168 horas após a condensaçäo. A utilizaçäo de brocas multilaminadas para o acabamento superficial dos corpos-de-prova exibiu níveis de rugosidade semelhante aos corpos-de-prova näo polidos. No tocante às ligas utilizadas, a liga DFL mostrou os mais altos valores de rugosidade superficial, enquanto a liga GS 80 exibiu os melhores valores. A trituraçäo foi efetuada segundo a indicaçäo dos fabricantes e o amálgama foi condensado em uma matriz de aço fabricada especialmente para a pesquisa. A matriz tinha uma cavidade de 4,0 mm de diâmetro com 2,0 mm de profundidade. Cinco minutos após a condensaçäo, foi feita a escultura com uma lâmina de aço e em seguida a brunidura. Depois de 25 minutos, o corpo-de-prova de amálgama era retirado utilizando-se um parafuso da própria matriz. Entäo, 168 h após a condensaçäo, os corpos-de-prova eram polidos e submetidos aos testes de rugosimetria


Subject(s)
Dental Amalgam/analysis , Dental Alloys , Dental Polishing/methods , Dental Restoration, Permanent/methods
20.
Rev. Fac. Odontol. Univ. Chile ; 17(2): 9-28, jul-dic. 1999. tab, graf
Article in Spanish | LILACS | ID: lil-285020

ABSTRACT

Se realizó un análisis comparativo in vitro de tres propiedades mecánicas de dos cerómetros (Artglass de Heraeus-Kulzer y Targis de Vivadent-Ivoclar) y una resina compuesta de procesado indirecto (SR_Isosit de Vivadent-Ivoclar). Las pruebas mecánicas realizadas fueron: a) Test de tracción bajo comprensión o tensión diametral. b) Análisis de resistencia al desgaste por abrasión, y por último, C) Prueba de dureza superficial Vickers. Todos los resultados obtenidos fueron tabulados y sometidos a los tests estadísticos Anova y Tukey. Los resultados obtenidos mostraron que en las tres pruebas realizadas, SR_Isosit fue superior a Targis y Artglass, mostrando diferencias significativas respecto a los otros materiales. Por otro lado, Artglass obtuvo mejores resultados que Targis en las tres pruebas analizadas, pero con diferencias significativas solo en el test de tensión diametral y en la prueba de resistencia al desgaste. targis obtuvo los valores más bajo en las tres pruebas mecánicas realizadas


Subject(s)
Composite Resins/analysis , Dental Cements/analysis , In Vitro Techniques , Biocompatible Materials/analysis , Dental Amalgam/analysis , Dental Porcelain/analysis , Gold Alloys/analysis
SELECTION OF CITATIONS
SEARCH DETAIL