Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 468
Filter
1.
Clin Oral Investig ; 28(10): 527, 2024 Sep 16.
Article in English | MEDLINE | ID: mdl-39279004

ABSTRACT

AIM: This is a report of the 5-year results of a two-group parallel randomized clinical trial comparing longitudinal implant stability, and clinical and radiographic peri-implant outcomes of mandibular overdentures retained by one (1-IOD group) or two (2-IOD group) implants. METHODS: All participants received 4.1 mm diameter tissue-level implants (Straumann® Standard Plus - SLActive®, Institut Straumann AG), installed in the mandible midline (1-IOD; n = 23) or the lateral incisor-canine area bilaterally (2-IOD; n = 24), and loaded after 3 weeks. Implant Stability Quotient (ISQ) was measured using a resonance frequency device (Osstell® Mentor, Integration Diagnostics) at implant placement, after three weeks (loading), and at the 6-month, 1-, 3-, and 5-year follow-ups. Marginal bone loss and clinical implant outcomes (plaque, calculus, suppuration and bleeding) were assessed periodically up to 5 years after loading. RESULTS: Only minor changes in marginal bone level were observed after 5 years (mean = 0.37; SD = 0.44 mm), and satisfactory and stable peri-implant parameters were observed throughout the 5-year follow-up. No significant differences between groups were found. Overall, the mean primary implant stability was considered high (> 70) for the two groups (1-IOD = 78.1 ± 4.5; 2-IOD = 78.0 ± 5.8). No noticeable changes were observed between implant insertion and loading. A marked increase was observed from insertion to the 6-month follow-up - the mean difference for the 1-IOD group was + 5.5 ± 5.5 (Effect size = 1.00), while for the 2-IOD group, the mean difference was + 6.0 ± 5.6 (Effect size = 1.08). No relevant changes were observed throughout the follow-up periods up to 5 years. Linear mixed-effect model regression showed no influence of the bone-related variables (p > 0.05) and the number of implants (p = 0.087), and a significant effect of the time variable (p < 0.001). CONCLUSION: Satisfactory peri-implant outcomes and stable secondary stability suggest good clinical performance and successful long-term osseointegration of the implants for single and two-implant mandibular overdentures. Using a single implant to retain a mandibular overdenture does not seem to result in detrimental implant loading over the five years of overdenture use. CLINICAL RELEVANCE: This study corroborates the use of a single implant to retain a mandibular denture.


Subject(s)
Dental Prosthesis, Implant-Supported , Denture Retention , Denture, Overlay , Mandible , Humans , Male , Female , Mandible/surgery , Aged , Middle Aged , Treatment Outcome , Dental Implantation, Endosseous/methods , Denture, Complete, Lower , Alveolar Bone Loss/diagnostic imaging , Resonance Frequency Analysis
2.
J Oral Rehabil ; 51(11): 2354-2360, 2024 Nov.
Article in English | MEDLINE | ID: mdl-39128892

ABSTRACT

BACKGROUND: The literature is unclear about how the different attachment systems for overdentures impact the maximum bite force, the masticatory efficiency and how this impact in the oral health self-perception in patients. OBJECTIVE: To evaluate the effect of two attachment systems (O-ring and Locator) for mandibular overdenture using single implant on quality of life, maximum bite force (BF) and masticatory efficiency (ME). METHODS: Twenty-eight completely edentulous denture wearers with a mandibular symphysis implant were randomly selected and allocated into two groups in a crossover study, considering O-ring and Locator attachment types. The quality of life and self-perception of oral health were assessed using the Oral Health Impact Profile (OHIP-Edent) and Geriatric Index of Determination of Oral Health (GOHAI) questionnaires, respectively. BF was measured using a gnathodynamometer and ME by chewing silicone cubes and almonds in different numbers of cycles. RESULTS: There was no difference between the attachment systems about self-perceived oral health and impact on quality of life (p > .05). The O-ring-type system obtained a significantly higher BF than the locator-type system (p = .04). Regardless of the food chewed, no statistically significant difference was observed with the type of attachment (p > .05). The ME was directly proportional to the masticatory cycles only for almonds (p < .01). CONCLUSIONS: Locator and O-ring inserts had a similar impact on patients' quality of life, self-perception of oral health and ME. Additionally, the O-ring system exhibited superior properties in the BF.


Subject(s)
Bite Force , Cross-Over Studies , Denture, Overlay , Mastication , Oral Health , Quality of Life , Self Concept , Humans , Male , Mastication/physiology , Female , Aged , Denture Retention , Middle Aged , Dental Prosthesis, Implant-Supported , Denture Design
3.
J Dent ; 149: 105267, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39067647

ABSTRACT

AIM: The positive impact of implant interventions on dental patient-reported outcomes is an essential parameter of treatment effectiveness. This study assessed the 2-year changes in patient satisfaction and oral health-related quality of life (OHRQoL) of edentulous patients treated with a four mini implant mandibular overdenture (IOD) METHODS: The study was planned as a 2 × 2 factorial randomized clinical trial that tested two surgical approaches (flapped or flapless) and two loading protocols (immediate and delayed) using a titanium-zirconium mini implant (Straumann Mini Implant System®) and a PEEK retentive system (Straumann® Optiloc® Retentive System). Outcome measures (OHIP-Edent scores and the McGill Denture Satisfaction questionnaire) were assessed before treatment and at the 3-, 6-, 12-, and 24-month follow-ups. The Friedman test and multiple regression using Generalized Estimating Equations (GEE) were used for data analysis, considering the per-protocol (PP) and intention-to-treat (ITT) approaches RESULTS: Seventy-four patients were randomized to the study groups. No implant failure occurred during the study period. Marked improvement in all post-treatment periods compared to baseline were observed for the two outcomes. No significant effect of patient's gender, age, and surgical protocol on the study outcomes. The effect of treatment provision was significant for the two outcomes in the PP and ITT approaches (p < 0.001). A barely significant positive effect of the immediate loading was observed for OHIP-Edent in the PP approach (p = 0.020) CONCLUSION: IOD treatment significantly improved patient-reported outcomes measures, with sustained benefits over the two years of overdenture use, and can be considered a promising treatment option in for the edentulous mandible.


Subject(s)
Dental Implants , Dental Prosthesis, Implant-Supported , Denture, Overlay , Jaw, Edentulous , Mandible , Patient Reported Outcome Measures , Patient Satisfaction , Quality of Life , Titanium , Zirconium , Humans , Male , Female , Middle Aged , Aged , Mandible/surgery , Jaw, Edentulous/rehabilitation , Jaw, Edentulous/surgery , Denture Retention , Treatment Outcome , Denture, Complete, Lower , Denture Design , Oral Health , Immediate Dental Implant Loading
4.
J Dent ; 149: 105266, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39067651

ABSTRACT

OBJECTIVE: This 2-year prospective study reports the incidence of prosthetic complications and maintenance events after treatment with mandibular overdenture retained by four mini implants opposed to a maxillary denture. METHODS: Implant intervention included flapless or flapped surgery combined with immediate or delayed loading, as part of a randomized clinical trial. Four one-piece titanium-zirconium mini-implants (Straumann Mini Implant System) were inserted, and the retentive PEEK elements (Optiloc) were incorporated into the overdenture using chairside procedures. Prosthodontic complications and maintenance events were recorded over a 2-year follow-up, and the final outcome was defined according to standardized criteria. Data analysis included descriptive statistics, incidence and incidence density rates, and Kaplan-Meier survival. RESULTS: 73 out of 74 patients (64.9 % female), mean age of 64 (SD=8.2) years, completed the study follow-up (one withdrew after 9 months). Implant survival was 100 %. A total of 163 prosthodontic events occurred in 53 patients (72.6 %), and 20 patients had no clinical complaints or maintenance needs. The most common procedures were adjustment/repair of the overdenture base (47.0 %), replacement of retentive inserts (19.8 %), and laboratory relining (12.9 %). A high prosthodontic success rate was achieved (93.2 %), and all patients presented serviceable overdentures and continuous use after the resolution of prosthodontic complications. The incidences of matrix replacement and laboratory relines were low in the first year, while denture base adjustments were common within the first year, especially in the first 6 months. CONCLUSION: The mini implant system showed high prosthodontic success rates. Minor adjustments/repairs during the initial follow-up were common. Relines and matrix replacements tend to occur after one year of overdenture use, and matrix replacements may occur as a consequence of the need for relining.


Subject(s)
Dental Implants , Dental Prosthesis, Implant-Supported , Dental Restoration Failure , Denture Retention , Denture, Overlay , Titanium , Zirconium , Humans , Female , Male , Middle Aged , Follow-Up Studies , Prospective Studies , Denture Retention/instrumentation , Aged , Treatment Outcome , Mandible/surgery , Denture Design , Denture Repair , Denture, Complete, Lower
5.
J Oral Rehabil ; 51(10): 1947-1955, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38873742

ABSTRACT

BACKGROUND: Limited data exist on the mid- to long-term masticatory capacity of mandibular overdenture (IOD) wearers, particularly regarding the use of posterior implants to retention. OBJECTIVES: To periodically evaluate mastication of IOD wearers, comparing the effectiveness of two to four implants to retain the prosthesis. METHODS: In a randomised controlled clinical trial, 20 complete edentulous patients (14 women), aged 51-84 years (mean age 69.1 ± 9.6), received new bimaxillary complete dentures (CD). After adaptation, baseline measurements of masticatory performance (X50) and swallowing threshold were conducted using the sieving method. Patients were then randomly assigned to groups: control (two intra-foraminal regular implants) and experimental (two intra-foraminal regular implants and two extra-short posterior implants) (n = 10 each). After 4 months, implants were splinted, and a new mandibular IOD was fabricated with bar/clip retention. Mastication was reassessed after 6, 12, and 48 months, and data analysed with repeated measures ANOVA and Sidak's post hoc (α = 0.05). RESULTS: Despite a loss of two patients per group, masticatory performance significantly improved after mandibular IOD installation (p = .031) in both groups (p = .670). A second improvement was observed after 6 months (p = .027), with no subsequent changes (p > .05). Swallowing threshold improvements were noted with IOD, and no discernible differences between groups were observed (p > .05). CONCLUSION: Masticatory function significantly improved after mandibular IOD installation, with the number of implants demonstrating minimal influence. CLINICAL TRIAL REGISTRATION: The present study was not registered in a public database, as mandated. It is important to note that the recommendation for registration was initiated in 2017 by the Committee of Medical Journal Editors, while patient inclusion in the research took place in 2016. Given that the data presented in this manuscript cover a follow-up period of up to 4 years post-surgical intervention, delayed registration was not feasible.


Subject(s)
Dental Prosthesis, Implant-Supported , Denture Retention , Denture, Complete, Lower , Denture, Overlay , Mandible , Mastication , Humans , Mastication/physiology , Female , Male , Middle Aged , Aged , Aged, 80 and over , Mandible/surgery , Jaw, Edentulous/rehabilitation , Jaw, Edentulous/physiopathology , Dental Implants , Treatment Outcome
6.
J Oral Rehabil ; 51(8): 1459-1467, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38685704

ABSTRACT

OBJECTIVE: This prospective study is part of a randomised clinical trial and reports the changes in masticatory performance (MP) and bite force, and explores their influential factors, 1 year after the provision of mandibular overdentures retained by four titanium-zirconium mini implants. METHODS: Edentulous patients received conventional complete dentures, followed by placement of four mini implants (Straumann® Mini Implant System) in the anterior mandible and converting the conventional prosthesis into a mandibular overdenture. Treatment protocols were randomised using a 2×2 factorial design combining different surgical (flapped vs. flapless) and loading (immediate vs. delayed) protocols. MP was assessed using a two-colour mixing ability test and a colorimetric analysis to measure the level of colour mixing (Variance of Hue-VoH). Maximum voluntary bite force (MBF) was measured by a digital gnathodynamometer in the posterior and anterior regions. Sex, age, surgical and loading protocols and ridge morphology were tested as independent variables. MP and MBF tests were performed at baseline (pre-treatment) and the 3-, 6- and 12-month after implant loading. Descriptive statistics, independent t-test, and linear mixed-effect model (LMM) regression were used for data analysis. RESULTS: Seventy-four participants were assessed and 73 completed the 1-year follow-up. Statistically significant improvements in functional parameters were observed in all follow-up periods compared to baseline (p < .001). The flapless protocol was associated with higher improvement in MP at the 3-month follow-up (p = .004), while less resorbed ridges were associated with better MP (p = .038) and higher MBF (p < .001). CONCLUSION: The mandibular overdenture protocol using four titanium-zirconium mini implants was effective in improving MP and MBF of edentulous patients, compared to pre-treatment values. The findings also suggest that improvements in chewing function and bite force are impacted by clinical factors since better outcomes were observed for flapless surgeries and less resorbed edentulous ridges. CLINICAL TRIAL REGISTRATION: ClinicalTrials.Gov ID NCT04760457.


Subject(s)
Bite Force , Dental Prosthesis, Implant-Supported , Denture, Overlay , Mandible , Mastication , Titanium , Zirconium , Humans , Male , Female , Mastication/physiology , Prospective Studies , Aged , Mandible/surgery , Middle Aged , Dental Implants , Treatment Outcome , Denture Retention/methods , Denture, Complete, Lower , Jaw, Edentulous/rehabilitation , Jaw, Edentulous/surgery
7.
Rev. Asoc. Odontol. Argent ; 111(3): 1111212, sept.-dic. 2023. ilus, tab
Article in Spanish | LILACS | ID: biblio-1554482

ABSTRACT

Objetivo: Comparar dos procedimientos de soldadura convencionales empleando una aleación de Cr-Co, para co- nectar barras coladas seccionadas a ser fijadas sobre implantes. Materiales y métodos: A partir de un modelo maes- tro que representa un maxilar desdentado con cuatro implan- tes, se confeccionaron veinte (n=20) probetas seccionadas en tres partes. Se conformaron dos grupos, cada uno con diez (n=10) ejemplares. Una vez acondicionadas, fueron atornilla- das al modelo maestro. Su desajuste inicial se analizó utili- zando una lupa estereoscópica, con una cámara incorporada y un software. Las partes fueron soldadas empleando un pro- cedimiento diferente para cada grupo. Las correspondientes al Grupo I se invistieron en un block refractario a base de sílico-fosfato. Las del Grupo II se montaron en una estructu- ra metálica Clever Spider. El desajuste fue mensurado y los resultados procesados estadísticamente. El nivel de significa- ción fue establecido en p<0,05. Resultados: El Grupo I tuvo un desajuste inicial de 97,30±13,81µm y el Grupo II de 98,53±11,24µm. Luego de la soldadura, el Grupo I registró 98,53±17,17µm, 1,23µm mayor respecto al inicial. En el Grupo II se observó 103,13±17,61µm, 4,60µm por encima del original. Se analizaron mediante prue- ba t de Student; en ambos casos el resultado fue de p>0,05. Al comparar entre sí los grupos I y II, por medio de la prueba t y de comprobación no paramétrica de Mann-Whitney, se ob- servaron diferencias no significativas, p=0,41 y p=0,38 res- pectivamente (AU)


Aim: Compare two conventional welding procedures us- ing a Cr-Co alloy, to connect sectioned cast bars to be fixed on implants. Materials and methods: From a master model representing a toothless jaw with four implants, twenty (n=20) specimens sectioned into three parts were made. Two groups were formed, each with ten (n=10) specimens. Once conditioned, they were screwed to the master mod- el. Its initial mismatch was analyzed using a stereoscop- ic magnifier, with a built-in camera and a software. The parts were welded using a different procedure for each group. Those corresponding to Group I were invested in a refractory block based on silyl-phosphate. Those of Group II were mounted on a Clever Spider metal structure. The mismatch was measured, and the results processed statisti- cally. The level of significance was established at p<0.05. Results: Group I had an initial mismatch of 97.30 ±13.81µm, and Group II of 98.53±11.24µm. After welding, Group I registered 98.53±17.17µm, 1.23µm higher than the initial one. In Group II, 103.13±17.61µm was observed, 4.60µm above the original. They were analyzed using Stu- dent's t test; in both cases the result was p>0.05. When com- paring groups I and II, using the t-test and the Mann-Whitney nonparametric verification, non-significant differences were observed, p=0.41 and p=0.38 respectively. Conclusions: Under the conditions of this study, it was ob- served that the two welding methods analyzed were reliable for joining metallic superstructures without affecting their final fit (AU)


Subject(s)
Dental Soldering , Dental Prosthesis Retention/methods , Prosthesis Fitting/methods , Dental Prosthesis, Implant-Supported/methods , Data Interpretation, Statistical , Chromium Alloys/chemical synthesis , Denture, Overlay
8.
J Oral Rehabil ; 50(12): 1508-1517, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37605296

ABSTRACT

BACKGROUND: Adequate muscle activity is important for the success of oral rehabilitation: it maintains the integrity of the stomatognathic system and is responsible for chewing movements needed to break, crush and grind food. OBJECTIVE: To compare muscle activity using electromyography (EMG) while clenching or chewing soft and/or hard foods among individuals with natural dentition (ND) and edentulous patients rehabilitated with dental prostheses. METHODS: This review was conducted until March, 2023, and the research question was "Is the muscle activity of edentulous patients rehabilitated with dental prostheses similar to that of dentate individuals?" A search strategy was conducted in PubMed/MEDLINE, The Cochrane Library, Web of Science, Lilacs, Embase and manual journal searches. RESULTS: Ten studies were included in the analysis. Most of them reported that individuals with ND had significant higher muscle activity (clenching or chewing) than complete dentures (CD) users. However, no difference was observed between patients with full mouth implant-supported fixed dental prosthesis (ISFDP) and ND. Additionally, two studies compared patients with mandibular ISFDP with maxillary CD and individuals with ND and found no differences; however, one study concluded that patients with ISFDP with CD (maxillary or mandibular) had lower muscle activity than individuals with ND. Only one study reported a higher muscle activity in patients with full-mouth ISFDP than in individuals with ND. CONCLUSIONS: Bimaxillary CD users had lower muscle activity than individuals with ND. During rehabilitation, the muscle activity of patients with full-mouth ISFDP and mandibular ISFDP with maxillary CD is similar to individuals with ND.


Subject(s)
Dental Implants , Mouth, Edentulous , Humans , Dental Prosthesis, Implant-Supported , Mouth, Edentulous/rehabilitation , Denture, Complete , Mastication/physiology , Muscles , Denture, Overlay
9.
J Appl Oral Sci ; 31: e20230054, 2023.
Article in English | MEDLINE | ID: mdl-37646715

ABSTRACT

Currently, there is no consensus on the indications and clinical performance of implant-supported overdentures (IODs) involving computer-aided design and manufacturing (CAD-CAM) bars. OBJECTIVE: To evaluate the performance of IODs involving CAD-CAM bars. METHODOLOGY: A comprehensive search of studies published until May 2023 was conducted in many databases, including PubMed/MEDLINE, Web of Science, Cochrane Library, and SciELO, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). The population, intervention, comparison, outcome (PICO) question was: "How do IODs retained by bars fabricated by CAD-CAM technology perform in daily clinical practice?" The meta-analysis included clinical studies based on effect size and a two-tailed null test with a 95% confidence interval (CI). RESULTS: Ten studies were included in the meta-analysis. Among them, nine reported a 100% implant survival rate for all CAD-CAM milled bars. Complications were reported in two studies with CAD/CAM-milled titanium bars, and one study reported more fractures in soldered gold bars used in maxillary rehabilitation. However, no fractures were observed in IODs retained by PEEK and zirconia bars. According to six studies, biological complications, including peri-implantitis, were minimal in the BioHPP and PEEK bar groups, while no cases were reported in the titanium or zirconia bar groups. CAD-CAM-milled zirconia bars had higher plaque and bleeding indices compared with titanium bars, as evidenced by findings from five studies. All four studies that evaluated Oral Health Impact Profile (OHIP) scores showed a positive effect of IODs retained by CAD-CAM milled titanium bars on quality of life. Patient satisfaction and acceptance by prosthodontists were significantly high, according to the results of five studies. CONCLUSION: Overdentures retained with CAD-CAM milled titanium bars show great potential for use in daily clinical practice. Moreover, patient and practitioner satisfaction was very high when this method was used.


Subject(s)
Denture, Overlay , Quality of Life , Humans , Titanium , Computer-Aided Design
10.
Clin Oral Implants Res ; 34(8): 769-782, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37254798

ABSTRACT

OBJECTIVE: To report the 1-year implant survival/success and peri-implant outcomes of mandibular overdentures retained by four titanium-zirconium mini implants (Straumann® Mini Implant System), and to assess how surgery and loading protocols influence these outcomes. MATERIALS AND METHODS: A 2 × 2 factorial randomized clinical trial (RCT) tested the combined effects of two loading protocols (immediate or delayed) and two surgical approaches (flapless or flapped) on the success/survival of the mini implants, and peri-implant parameters (plaque, bleeding, sulcus depth, gingival position, and marginal bone loss). Outcomes were assessed up to 1-year after loading, and generalized estimating equations (GEEs) were used to analyze longitudinal and within-patient clustered data. RESULTS: Two hundred and ninety-six implants were placed in 74 patients. The implant survival/success rates after 1 year were 100%, and no major biological complications were observed. After 1-year, descriptive data suggest no noticeable changes in plaque scores, whilst a reduction in bleeding scores at the 6-month and 1-year follow-ups compared to baseline. Good longitudinal stability was observed for the probing depth and gingival margin height measures. Overall mean marginal bone loss was 0.68 (±0.68) mm after 3 months and 0.89 (±0.75) mm after 1-year. The flapless protocol showed better results on soft tissue stability and health but a slightly higher risk for marginal bone loss. CONCLUSION: The results of this RCT suggest that mandibular overdentures retained by this novel mini implant system represent a safe and predictable treatment option as confirmed by implant survival/success and peri-implant outcomes, even when flapless surgery and immediate loading protocols are adopted.


Subject(s)
Alveolar Bone Loss , Dental Implants , Immediate Dental Implant Loading , Humans , Titanium , Zirconium , Denture, Overlay , Dental Implantation, Endosseous/methods , Mandible/surgery , Dental Prosthesis, Implant-Supported/adverse effects , Treatment Outcome , Follow-Up Studies , Alveolar Bone Loss/etiology
11.
Dent Med Probl ; 60(1): 167-176, 2023.
Article in English | MEDLINE | ID: mdl-37023344

ABSTRACT

The ball attachments and their O-rings used for the retention and stabilization of overdentures showed a decrease in retention as the number of cycles increased. This fact resulted in a decrease in the retention of the prosthesis. The purpose of this study was to evaluate the fatigue resistance of ball attachments through a systematic review. An electronic search was performed using the Cochrane Library, LILACS, PubMed, ScienceDirect, and Web of Science databases. The search was conducted based on the PICOS framework. The inclusion criteria involved in the search comprised research articles written in English and published between the years 2000 and 2020. In the final selection, 18 articles were included in the review. Most of these studies performed the fatigue retention tests using parallel implants without angles. However, some studies used different angles to analyze the fatigue retention values. With the passage of time, the wear results in deformation and, as a consequence, a decrease in the retention of most attachments, leading to treatment failure. The main factor to be considered is the loss of retention of these components and their low durability. The loss of retention is due to large extent to the materials used to manufacture the attachments and O-rings, the size and angulation of the implants, and the length of the prosthesis. Future research is needed to further elucidate the reasons for the failure of the attachments.


Subject(s)
Dental Implants , Humans , Dental Prosthesis, Implant-Supported/methods , Denture Retention/methods , Denture, Overlay
12.
J Oral Rehabil ; 50(5): 392-399, 2023 May.
Article in English | MEDLINE | ID: mdl-36789570

ABSTRACT

BACKGROUND: Several complete denture wearers have major complaints and may be benefitted from implant treatment. However, the factors that shape the demand for and utilization of implants need further investigation. OBJECTIVE: The aim was to evaluate edentulous patient's willingness to accept or refuse the offer and provision of implant-retained treatment. METHODS: As part of a clinical trial, edentulous subjects were offered a mandibular overdenture retained by four mini-implants opposing a conventional maxillary denture. Treatment was offered without any financial costs for the patients. Patients' level of interest in receiving treatment was assessed using a 5-point Likert scale, and they were asked to respond to a list of reasons that led to their decision to accept or refuse implants. Those who refused implants received conventional prosthodontic interventions as required, and those who accepted implant treatment underwent surgical planning and implant placement. RESULTS: Of 175 eligible subjects, 147 accepted the offer of treatment and were invited to take part in the study (69.4% women, mean age 67.4 ± 10.0 years). Overall, 111 patients (75.5%) expressed a positive intention to undergo implant treatment at the initial contact. Implant treatment was performed for 56.3% (9/16) of those who answered 'probably yes' about their level of interest in implant treatment on the Likert scale, and 69.6% (64/92) of 'certainly yes' (p < .001). Older subjects were less likely to receive implants (OR = 0.93; p = .036), whilst those with a positive intention towards implants (OR = 3.15; p = .001), those previously treated by the dental team (OR = 7.89; p < .001), and who actively demanded implants (OR = 18.1; p < .001) were more likely to accept treatment. Improved chewing was the most common reason for accepting implants, whilst fear of surgery was the most reported reason for refusal. CONCLUSION: Refusal of implants was high among edentate patients even when financial costs were removed. Patients' initial attitude towards acceptance is a key factor in the demand for and uptake of implant therapy.


Subject(s)
Dental Implants , Jaw, Edentulous , Mouth, Edentulous , Humans , Female , Middle Aged , Aged , Male , Prospective Studies , Patient Satisfaction , Denture, Overlay , Jaw, Edentulous/surgery , Mandible/surgery , Dental Prosthesis, Implant-Supported , Denture Retention
13.
Clin Oral Implants Res ; 34(3): 233-242, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36692124

ABSTRACT

OBJECTIVE: To assess the incidence of prosthodontic maintenance events and complications during 4 years of follow-up after mandibular overdenture treatment with one or two implants. METHODS: Participants received one or two implants inserted in the midline (1-IOD group) or the lateral incisor-canine area bilaterally (2-IOD group). Implants were loaded with an early loading protocol after 3 weeks. Programmed recall visits were scheduled at the 6-, 12-, 36-, and 48-month follow-ups and nonprogrammed visits in case of prosthodontic complaints. The type of maintenance was registered, and the final treatment outcome was classified as successful, surviving, unknown, dead, repair, or retreatment. RESULTS: Forty-seven participants, mean age 65.4 ± 8.6, 74.5% female, were included (1-IOD = 23; 2-IOD = 24) and 44 completed the 4-year follow-up. A total of 159 prosthodontic maintenance events occurred and 89 in unscheduled visits. The most common event was the need for minor modifications of the denture base due to sore spots in the oral mucosa (n = 56 in 31 patients), matrix activation (n = 54 in 34 patients), and overdenture fracture (n = 25 in 18 patients). A "successful" or "surviving" outcome could be attributed to 57.5% of cases, whereas 38.3% needed repair. No significant differences in the incidence of prosthodontic events or treatment outcomes were found between the two groups. CONCLUSIONS: Findings show that 1-IODs perform similar to 2-IODs when considering the incidence of fractures and the need for prosthodontic maintenance, including adjustments of the overdenture and the attachment system.


Subject(s)
Dental Implants , Female , Male , Animals , Denture, Overlay , Dental Prosthesis, Implant-Supported , Mandible , Treatment Outcome , Denture Retention
14.
Clin Implant Dent Relat Res ; 25(2): 426-434, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36623506

ABSTRACT

OBJECTIVE: The aim of this study was to assess the final insertion torque values achieved using site-specific drilling protocols for a novel mini implant system for removable complete overdentures. Anatomical and technical factors influencing final insertion torque were recorded and analyzed. MATERIAL AND METHODS: Participants were randomized to two surgical protocol groups (flapped or flapless) and all received four mini implants (Straumann® mini implant system; Straumann AG) in the anterior mandible, using a 1.6 mm needle drill and a 2.2 mm pilot drill for the implant bed site preparation. The final insertion torque was recorded as the main outcome variable during surgery. Bone type, radiographical bone density, ridge form, implant length, and the drilling protocol were considered as independent variables. Descriptive statistics, generalized estimating equations (GEE) regression, and heatmap charts were used for data analyses. RESULTS: A total of 296 mini implants were placed in 74 patients (mean age = 64.1 ± 8.0; 64.9% female) using flapless (n = 37) or flapped (n = 37) surgeries. Mean final insertion torque was 55.8 ± 18.4 Ncm (10.5% > 35 Ncm, 48.9% between 35 and 65 Ncm, and 40.6% > 65 Ncm). The needle drill was used in only 43.9% of the implant bed sites. Higher final torque values were observed for higher bone densities (bone type I > II > III, and D1-D2 > D3-D4), highly resorbed ridge forms (5-6 > 3-4), flapped surgeries, and male patients. However, regression models showed that the likelihood of achieving optimal insertion torque (≥35 and ≤65 Ncm) was higher for females (OR = 2.14; 95%CI = 1.14-4.01; p = 0.018), ridge forms 3-4 (OR = 2.87; 95%CI = 1.05-7.85; p = 0.040), and flapless surgeries (OR = 1.96; 95%CI = 1.09-3.51; p = 0.024). CONCLUSIONS: Sufficient primary stability for immediate loading was achieved for the majority of the mini implants placed. Surgical implant bed preparation should be site-specific to achieve optimal primary stability for immediate loading while avoiding excessive insertion torque.


Subject(s)
Dental Implantation, Endosseous , Dental Implants , Humans , Male , Female , Middle Aged , Aged , Dental Implantation, Endosseous/methods , Titanium , Cross-Sectional Studies , Zirconium , Torque , Denture, Overlay , Mandible/surgery , Randomized Controlled Trials as Topic
15.
J Prosthodont Res ; 67(2): 255-261, 2023 Apr 12.
Article in English | MEDLINE | ID: mdl-35786572

ABSTRACT

PURPOSE: This study aimed to assess patients' expected burdens before treatment and their perceived burdens after the surgical and prosthodontic procedures of mandibular overdenture treatment and to evaluate factors influencing patients' perceptions. METHODS: Data were collected from 47 participants enrolled in a randomized clinical trial comparing mandibular overdentures retained by one or two implants. A 20-item questionnaire measured on a four-point Likert scale covering the surgical and prosthetic treatment procedures was used to assess the patients' perception of the procedural burdens before (expected burdens) and immediately after (experienced burdens) each procedure. Operators' perceptions of intercurrences associated with the procedures were also assessed as an independent variable. RESULTS: Low levels of perceived burdens were observed both before and after treatment. The mean overall scores of 1.65 ± 0.46 and 1.53 ± 0.33 for expected and experienced burdens, respectively, indicated that most items ranged between "not burdensome at all" and "somewhat burdensome." Significant differences between expected and experienced burdens were found for eight items (P < 0.001). Considering the treatment stages, expected burdens scored higher in the pre-surgical, surgical, and prosthetic stages and lower in the post-surgical phase than experienced burdens. Overall, the experienced burdens were significantly affected by the expected burdens (P < 0.001) and operator's perceived burdens(P = 0.045). CONCLUSIONS: Treatments were associated with low levels of perceived burdens related to surgical and prosthodontic procedures and were highly correlated with the expected burdens before treatment. However, patients tend to overestimate the expected burdens before treatment, especially for surgical procedures.


Subject(s)
Dental Implants , Jaw, Edentulous , Humans , Denture, Overlay , Patient Satisfaction , Denture, Complete, Lower , Jaw, Edentulous/surgery , Mandible , Dental Prosthesis, Implant-Supported , Denture Retention , Treatment Outcome
16.
J Prosthet Dent ; 130(2): 220-228, 2023 Aug.
Article in English | MEDLINE | ID: mdl-34728072

ABSTRACT

STATEMENT OF PROBLEM: The medium-term effect of an implant-retained mandibular overdenture on bone remodeling in the maxilla and posterior mandible of edentulous patients and the effects on quality of life have not been established. PURPOSE: The purpose of this prospective observational clinical study was to evaluate the 3-year effects of implant-retained mandibular overdentures on oral-health-related quality of life (OHRQoL) and bone remodeling in different regions of the maxilla and mandible in participants with atrophic or nonatrophic mandibles. MATERIAL AND METHODS: Twenty-six edentulous participants received 2 narrow-diameter implants in the anterior mandible. Mandibular bone atrophy was categorized from presurgical panoramic radiographs according to the Cawood and Howell criteria. OHRQoL was assessed by using the OHIP-EDENT questionnaire. Participants were evaluated annually for 3 years to measure the marginal bone loss and bone area of the posterior mandible, and the anterior and posterior regions of the maxilla were assessed annually through panoramic radiographs. The data were analyzed by using a mixed-effects linear regression to estimate time-dependent trends and a mixed-effect linear regression model to verify differences between groups. The Pearson correlation coefficients between bone variables and 3-year OHIP-EDENT outcomes were calculated. RESULTS: In the third year, atrophic participants had a significantly lower marginal bone loss (0.02 mm) than nonatrophic participants (-0.39 mm) (P=.030). Differences were also found in the functional limitation (nonatrophic=1.82 ±1.75, atrophic participants=1.92 ±1.54; P=.018) and handicap domains (nonatrophic=0.36 ±0.54, atrophic participants=0.08 ±0.27; P=.003). For nonatrophic participants, comparisons between baseline and 3-year outcomes showed significant bone resorption as indicated by the area ratio in the anterior maxilla (P=.035), posterior maxilla (P=.022), and posterior mandible (P=.009). Conversely, the bone area of the anterior maxilla (P=.019) decreased in atrophic participants between baseline and year 1, while the bone area of the anterior maxilla and posterior mandible increased (P<.001) between years 1 and 3. Higher effect sizes were observed in the OHRQoL domains of the atrophic participants. CONCLUSIONS: Bone atrophy influenced both the OHRQoL profile and bone remodeling profile in different regions of the mandible and maxilla in mandibular overdenture users. In atrophic participants, bone tissue in both jaws responded positively to overdenture use, with bone apposition after the first year and bone area preservation in the anterior maxilla, posterior mandible, and peri-implant regions after 3 years of follow-up.


Subject(s)
Bone Resorption , Dental Implants , Jaw, Edentulous , Humans , Denture, Overlay , Maxilla/diagnostic imaging , Quality of Life , Mandible/surgery , Atrophy/etiology , Atrophy/pathology , Dental Prosthesis, Implant-Supported/adverse effects , Jaw, Edentulous/etiology
17.
J Prosthet Dent ; 129(6): 888-894, 2023 Jun.
Article in English | MEDLINE | ID: mdl-34517991

ABSTRACT

STATEMENT OF PROBLEM: How the masticatory function of complete denture wearers is influenced by the positioning and occlusion of posterior teeth or by the presence of a single mandibular implant is unclear. PURPOSE: The purpose of this randomized crossover clinical trial was to evaluate the masticatory efficiency of wearers of bimaxillary complete dentures and of wearers of maxillary complete denture and single implant-retained mandibular overdentures, both with bilateral balanced occlusion and lingualized occlusion. MATERIAL AND METHODS: Participants received 2 sets of complete dentures with interchangeable teeth in the mandibular prosthesis to allow a change in the occlusion scheme. Subsequently, 1 implant was placed in the mandibular symphysis region, and the mandibular complete dentures were converted to overdentures. The masticatory efficiency was measured by the sieve method for both occlusal schemes. RESULTS: Repeated measures ANOVA showed no statistically significant difference in the masticatory efficiency with the 2 occlusal schemes for conventional complete dentures (P=.707) or overdentures (P=.407). When comparing the type of prosthesis, statistical differences were found for masticatory efficiency (P=.012), with improved mastication for the overdentures. CONCLUSIONS: A mandibular single implant improved the masticatory efficiency of patients with complete dentures, but the occlusal scheme did not influence this factor.


Subject(s)
Dental Implants , Denture, Overlay , Humans , Patient Satisfaction , Denture, Complete , Mandible , Mastication , Dental Prosthesis, Implant-Supported
18.
J Prosthet Dent ; 130(5): 677-689, 2023 Nov.
Article in English | MEDLINE | ID: mdl-35120735

ABSTRACT

STATEMENT OF PROBLEM: Standard-diameter dental implants are not always applicable because of anatomic limitations of the residual ridge. Thus, mini-implants have been increasingly used and offer an alternative. However, data regarding prosthetic complications, maintenance factors, and clinical outcomes are limited. PURPOSE: The purpose of this systematic review and meta-analysis was to compare prosthetic complications and maintenance events and clinical outcomes in residual ridges rehabilitated with mandibular implant overdentures (IODs) by using standard implants or mini-implants. MATERIAL AND METHODS: Nine electronic databases were searched. Quantitative analyses to measure the risk ratio (RR) and standardized mean difference (SMD) were applied. Those methods were used to assess prosthetic complications and maintenance events (abutment adjustments, replacement of retentive element, occlusal adjustment, and overdenture fracture) and clinical outcomes related to postoperative pain, probing depth (PD), plaque index (PI), marginal bone loss (MBL), and implant survival rate. RESULTS: Altogether, 7 publications were selected. Mini-implants presented reduced abutment adjustments (RR 0.23 [0.07, 0.73], P=.01), replacement of retentive element (RR 0.41 [0.31, 0.54], P<.001), occlusal adjustment (RR 0.53 [0.31, 0.91], P=.02), and overdenture fracture (RR 0.46 [0.23, 0.94], P=.03) compared with standard implants. Additionally, mini-implants presented lower values for PI at 6 months (SMD -0.27 [-0.47, -0.08], P=.006) and 12 months (SMD -0.25 [-0.46, -0.05], P=.01). No additional tangible differences were noted. CONCLUSIONS: Mini-implants might be an alternative choice based on the number of prosthetic complications and maintenance events. This was also confirmed by the comparable clinical data between standard implants and mini-implants.


Subject(s)
Alveolar Bone Loss , Dental Implants , Humans , Denture, Overlay , Dental Prosthesis, Implant-Supported/adverse effects , Alveolar Bone Loss/etiology , Mandible/surgery
19.
J Prosthet Dent ; 130(4): 553-563, 2023 Oct.
Article in English | MEDLINE | ID: mdl-34916064

ABSTRACT

STATEMENT OF PROBLEM: Implant overdentures have been widely used as a treatment option for edentulous patients. However, the development of implants, aside from commercial growth, requires funding assistance to determine scientific reliability and clinical applications. Nonetheless, bibliometric studies in the implant overdenture field are lacking. PURPOSE: The purpose of this bibliometric analysis was to evaluate the prevalence of funding and its bibliometric associated parameters according to the financial assistance granted and the implant overdenture documentation over time. MATERIAL AND METHODS: Six databases were assessed, and 12 bibliometric parameters related to the economy, geographical origin, publication details, and corresponding author metrics were recorded. An incidence rate ratio was applied by using a multiple Poisson regression model (α=.05) to assess the association between funding and each bibliometric parameter. RESULTS: In total, 1369 studies published between 1986 and 2021 were assessed bibliometrically. The prevalence of funded studies was 34.8% (n=477). The parameter associated with the presence of funding was country income (P<.01), with those having a high and upper-middle income being more funded than those with a lower-middle and low income. Oceania and South America were the continents more frequently funded (P<.05), with Africa being the least frequent. Randomized and nonrandomized controlled trials, in vitro studies, and in silico studies were more funded (P<.001) than case reports and series. Stud and ball attachment systems were more funded (P<.01) than studies with more than 1 retention system. Funding increased over time (P<.01), and corresponding authors with a higher h-index had more studies funded (P<.05). CONCLUSIONS: The number of funded studies on implant overdentures increased over the years. Other bibliometric parameters such as country income, continent, study design, retention system, and corresponding author h-index were associated with the frequency of funded studies published.


Subject(s)
Dental Implants , Jaw, Edentulous , Mouth, Edentulous , Humans , Denture, Overlay , Reproducibility of Results , Bibliometrics , Dental Prosthesis, Implant-Supported , Denture Retention
20.
Braz. dent. sci ; 26(4): 1-12, 2023. ilus, tab
Article in Portuguese | LILACS, BBO - Dentistry | ID: biblio-1519603

ABSTRACT

ABSTRACT Objective: The aim of this study is to determine the effect of Advanced Platelet-Rich Fibrin on bone density and implant stability in immediately loaded- implant-assisted mandibular overdentures (Split-mouth study). Material and Methods: Ten completely edentulous patients received two implants in the mandibular canine region and locator attachments were used to retain immediately loaded- implant mandibular overdentures. Each patient served in two Groups, one Group for each side. One side of the mandible received an implant with topical application of Advanced Platelet-Rich Fibrin in the implant osteotomy site (Group I) and the other site received an implant without application of Advanced platelet-rich fibrin (Group II). Each patient was examined clinically for implant stability using Osstell Mentor device and radiographically by ultra-low dose CT scan to measure bone density around the implant at baseline, three, six months, and one year. Results: There were no statistically significant differences (P>.05) in bone density and implant stability among the studied Groups during one year follow-up period. Conclusion : Advanced Platelet-Rich Fibrin has no effect on bone density and implant stability in immediately loaded implant-assisted mandibular overdenture.(AU)


RESUMO Objetivo: O objetivo deste estudo é determinar o efeito da Fibrina Rica em Plaquetas Avançada na densidade óssea e estabilidade dos implantes em Overdentures mandibulares com carga imediata (estudo de boca dividida). Material e Métodos: Dez pacientes edêntulos foram submetidos à instalação de dois implantes mandibulares na região dos caninos e pilares locator foram utilizados como sistema de retenção para as overdentures mandibulares com carga imediata. Cada paciente participou nos dois grupos, sendo um grupo para cada lado. Um lado da mandíbula recebeu implante com aplicação tópica de Fibrina Rica em Plaquetas Avançada no local do sítio cirúrgico do implante (Grupo I) e o outro local recebeu implante sem aplicação de Fibrina Rica em Plaquetas Avançada (Grupo II). Cada paciente foi examinado clinicamente quanto à estabilidade do implante usando o dispositivo Osstell Mentor e radiograficamente por tomografia computadorizada de ultrabaixa dose para medir a densidade óssea ao redor do implante no início do estudo, três, seis meses e um ano. Resultados: Não houve diferenças estatisticamente significativas (P>0,05) na densidade óssea e na estabilidade do implante entre os grupos estudados durante o período de acompanhamento de um ano. Conclusão: A Fibrina Rica em Plaquetas Avançada não tem efeito na densidade óssea e na estabilidade de implantes em Overdentures mandibulares com carga imediata (AU)


Subject(s)
Humans , Middle Aged , Bone Density/drug effects , Denture, Overlay , Immediate Dental Implant Loading , Mandibular Osteotomy , Platelet-Rich Fibrin/chemistry , Radiography , Double-Blind Method , Cuspid/surgery , Mandible/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL