Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 3.052
Filter
1.
Food Res Int ; 187: 114353, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38763640

ABSTRACT

The food industry has grown with the demands for new products and their authentication, which has not been accompanied by the area of analysis and quality control, thus requiring novel process analytical technologies for food processes. An electronic tongue (e-tongue) is a multisensor system that can characterize complex liquids in a fast and simple way. Here, we tested the efficacy of an impedimetric microfluidic e-tongue setup - comprised by four interdigitated electrodes (IDE) on a printed circuit board (PCB), with four pairs of digits each, being one bare sensor and three coated with different ultrathin nanostructured films with different electrical properties - in the analysis of fresh and industrialized coconut water. Principal Component Analysis (PCA) was applied to observe sample differences, and Partial Least Squares Regression (PLSR) was used to predict sample physicochemical parameters. Linear Discriminant Analysis (LDA) and Partial Least Square - Discriminant Analysis (PLS-DA) were compared to classify samples based on data from the e-tongue device. Results indicate the potential application of the microfluidic e-tongue in the identification of coconut water composition and determination of physicochemical attributes, allowing for classification of samples according to soluble solid content (SSC) and total titratable acidity (TTA) with over 90% accuracy. It was also demonstrated that the microfluidic setup has potential application in the food industry for quality assessment of complex liquid samples.


Subject(s)
Cocos , Dielectric Spectroscopy , Principal Component Analysis , Cocos/chemistry , Least-Squares Analysis , Dielectric Spectroscopy/methods , Discriminant Analysis , Water/chemistry , Food Analysis/methods , Microfluidics/methods , Microfluidics/instrumentation , Electronic Nose
2.
Sensors (Basel) ; 24(9)2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38732847

ABSTRACT

The most reliable methods for pregnancy diagnosis in dairy herds include rectal palpation, ultrasound examination, and evaluation of plasma progesterone concentrations. However, these methods are expensive, labor-intensive, and invasive. Thus, there is a need to develop a practical, non-invasive, cost-effective method that can be implemented on the farm to detect pregnancy. This study suggests employing microwave dielectric spectroscopy (MDS, 0.5-40 GHz) as a method to evaluate reproduction events in dairy cows. The approach involves the integration of MDS data with information on milk solids to detect pregnancy and identify early embryonic loss in dairy cows. To test the ability to predict pregnancy according to these measurements, milk samples were collected from (i) pregnant and non-pregnant randomly selected cows, (ii) weekly from selected cows (n = 12) before insemination until a positive pregnancy test, and (iii) daily from selected cows (n = 10) prior to insemination until a positive pregnancy test. The results indicated that the dielectric strength of Δε and the relaxation time, τ, exhibited reduced variability in the case of a positive pregnancy diagnosis. Using principal component analysis (PCA), a clear distinction between pregnancy and nonpregnancy status was observed, with improved differentiation upon a higher sampling frequency. Additionally, a neural network machine learning technique was employed to develop a prediction algorithm with an accuracy of 73%. These findings demonstrate that MDS can be used to detect changes in milk upon pregnancy. The developed machine learning provides a broad classification that could be further enhanced with additional data.


Subject(s)
Microwaves , Milk , Animals , Female , Cattle , Milk/chemistry , Pregnancy , Principal Component Analysis , Dielectric Spectroscopy/methods , Dairying/methods , Pregnancy Tests/methods , Pregnancy Tests/veterinary , Algorithms
3.
BMC Oral Health ; 24(1): 501, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38725023

ABSTRACT

BACKGROUND: Releasing of metal ions might implicate in allergic reaction as a negative subsequent of the corrosion of Stainless Steel (SS304) orthodontic wires. The aim of this study was to evaluate the corrosion resistance of zinc-coated (Zn-coated) SS orthodontic wires. METHODS: Zinc coating was applied on SS wires by PVD method. Electrochemical impedance spectroscopy (EIS), Potentiodynamic polarization tests and Tafel analysis methods were used to predict the corrosion behavior of Zn-coated and uncoated SS wires in both neutral and acidic environments. RESULTS: The values of Ecorr ,icorr and Rct ,which were the electrochemical corrosion characteristics, reported better corrosion behavior of Zn-coated SS wires against uncoated ones in both artificial saliva and fluoride-containing environments. Experimental results of the Tafel plot analyses were consistent with that of electrochemical impedance spectroscopy analyses for both biological solutions. CONCLUSION: Applying Zn coating on bare SS orthodontic wire by PVD method might increase the corrosion resistance of the underlying stainless-steel substrate.


Subject(s)
Dielectric Spectroscopy , Materials Testing , Orthodontic Wires , Saliva, Artificial , Stainless Steel , Zinc , Corrosion , Stainless Steel/chemistry , Zinc/chemistry , Saliva, Artificial/chemistry , Dental Alloys/chemistry , Coated Materials, Biocompatible/chemistry , Fluorides/chemistry , Hydrogen-Ion Concentration , Humans , Surface Properties , Potentiometry
4.
Sensors (Basel) ; 24(7)2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38610409

ABSTRACT

Electrical impedance spectroscopy (EIS) has been proposed as a promising noninvasive method to differentiate healthy thyroid from parathyroid tissues during thyroidectomy. However, previously reported similarities in the in vivo measured spectra of these tissues during a pilot study suggest that this separation may not be straightforward. We utilise computational modelling as a method to elucidate the distinguishing characteristics in the EIS signal and explore the features of the tissue that contribute to the observed electrical behaviour. Firstly, multiscale finite element models (or 'virtual tissue constructs') of thyroid and parathyroid tissues were developed and verified against in vivo tissue measurements. A global sensitivity analysis was performed to investigate the impact of physiological micro-, meso- and macroscale tissue morphological features of both tissue types on the computed macroscale EIS spectra and explore the separability of the two tissue types. Our results suggest that the presence of a surface fascia layer could obstruct tissue differentiation, but an analysis of the separability of simulated spectra without the surface fascia layer suggests that differentiation of the two tissue types should be possible if this layer is completely removed by the surgeon. Comprehensive in vivo measurements are required to fully determine the potential for EIS as a method in distinguishing between thyroid and parathyroid tissues.


Subject(s)
Dielectric Spectroscopy , Thyroid Gland , Thyroid Gland/surgery , Pilot Projects , Computer Simulation , Electricity
5.
Mol Pharm ; 21(5): 2315-2326, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38644570

ABSTRACT

The main purpose of our studies is to demonstrate that commercially available mesoporous silica (MS) can be used to control the physical state of aripiprazole (ARP). The investigations performed utilizing differential scanning calorimetry and broadband dielectric spectroscopy reveal that silica can play different roles depending on its concentration in the system with amorphous ARP. At low MS content, it activates recrystallization of the active pharmaceutical ingredient and supports forming the III polymorphic form of ARP. At intermediate MS content (between ca. 27 and 65 wt %), MS works as a recrystallization inhibitor of ARP. At these concentrations, the formation of III polymorphic form is no longer favorable; therefore, it is possible to use this additive to obtain ARP in either IV or X polymorphic form. At the same time, employing MS in concentrations >65 wt % amorphous form of ARP with high physical stability can be obtained. Finally, regardless of the polymorphic form it crystallizes into, each composite is characterized by the same temperature dependence of relaxation times in the supercooled and glassy states.


Subject(s)
Aripiprazole , Calorimetry, Differential Scanning , Crystallization , Silicon Dioxide , Aripiprazole/chemistry , Silicon Dioxide/chemistry , Porosity , Dielectric Spectroscopy , X-Ray Diffraction
6.
ACS Infect Dis ; 10(5): 1644-1653, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38602317

ABSTRACT

This study describes the synthesis of amino-functionalized carbon nanoparticles derived from biopolymer chitosan using green synthesis and its application toward ultrasensitive electrochemical immunosensor of highly virulent Escherichia coli O157:H7 (E. coli O157:H7). The inherent advantage of high surface-to-volume ratio and enhanced rate transfer kinetics of nanoparticles is leveraged to push the limit of detection (LOD), without compromising on the selectivity. The prepared carbon nanoparticles were systematically characterized by employing CO2-thermal programmed desorption (CO2-TPD), Fourier transform infrared (FTIR) spectroscopy, X-ray photoelectron spectroscopy (XPS), ultraviolet-visible (UV-visible), and transmission electron microscopy (TEM). The estimated limit of detection of 0.74 CFU/mL and a sensitivity of 5.7 ((ΔRct/Rct)/(CFU/mL))/cm2 in the electrochemical impedance spectroscopy (EIS) affirm the utility of the sensor. The proposed biosensor displayed remarkable selectivity against interfering species, making it well suited for real-time applications. Moreover, the chitosan-derived semiconducting amino-functionalized carbon shows excellent sensitivity in a comparative analysis compared to highly conducting amine-functionalized carbon synthesized via chemical modification, demonstrating its vast potential as an E. coli sensor.


Subject(s)
Biosensing Techniques , Carbon , Chitosan , Dielectric Spectroscopy , Escherichia coli O157 , Escherichia coli O157/isolation & purification , Biosensing Techniques/methods , Carbon/chemistry , Chitosan/chemistry , Nanoparticles/chemistry , Limit of Detection , Green Chemistry Technology
7.
Biosensors (Basel) ; 14(4)2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38667169

ABSTRACT

With the increasing incidence of diverse global bacterial outbreaks, it is important to build an immutable decentralized database that can capture regional changes in bacterial resistance with time. Herein, we investigate the use of a rapid 3D printed µbiochamber with a laser-ablated interdigitated electrode developed for biofilm analysis of Pseudomonas aeruginosa, Acinetobacter baumannii and Bacillus subtilis using electrochemical biological impedance spectroscopy (EBIS) across a 48 h spectrum, along with novel ladder-based minimum inhibitory concentration (MIC) stencil tests against oxytetracycline, kanamycin, penicillin G and streptomycin. Furthermore, in this investigation, a search query database has been built demonstrating the deterministic nature of the bacterial strains with real and imaginary impedance, phase, and capacitance, showing increased bacterial specification selectivity in the 9772.37 Hz range.


Subject(s)
Microbial Sensitivity Tests , Pseudomonas aeruginosa , Pseudomonas aeruginosa/drug effects , Acinetobacter baumannii , Biofilms , Bacillus subtilis , Dielectric Spectroscopy , Databases, Factual , Bacteria , Anti-Bacterial Agents/pharmacology
8.
Biosensors (Basel) ; 14(4)2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38667189

ABSTRACT

L-Lactate is an important bioanalyte in the food industry, biotechnology, and human healthcare. In this work, we report the development of a new L-lactate electrochemical biosensor based on the use of multiwalled carbon nanotubes non-covalently functionalized with avidin (MWCNT-Av) deposited at glassy carbon electrodes (GCEs) as anchoring sites for the bioaffinity-based immobilization of a new recombinant biotinylated lactate oxidase (bLOx) produced in Escherichia coli through in vivo biotinylation. The specific binding of MWCNT-Av to bLOx was characterized by amperometry, surface plasmon resonance (SPR), and electrochemical impedance spectroscopy (EIS). The amperometric detection of L-lactate was performed at -0.100 V, with a linear range between 100 and 700 µM, a detection limit of 33 µM, and a quantification limit of 100 µM. The proposed biosensor (GCE/MWCNT-Av/bLOx) showed a reproducibility of 6.0% and it was successfully used for determining L-lactate in food and enriched serum samples.


Subject(s)
Avidin , Biosensing Techniques , Lactic Acid , Mixed Function Oxygenases , Nanotubes, Carbon , Nanotubes, Carbon/chemistry , Mixed Function Oxygenases/chemistry , Avidin/chemistry , Electrochemical Techniques , Surface Plasmon Resonance , Enzymes, Immobilized/chemistry , Escherichia coli , Biotinylation , Electrodes , Dielectric Spectroscopy , Limit of Detection
9.
Biosens Bioelectron ; 257: 116314, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38663325

ABSTRACT

Diarrheagenic E. coli infections, commonly treated with ß-lactam antibiotics, contribute to antibiotic resistance - a pressing public health concern. Rapid monitoring of pathogen antibiotic resistance is vital to combat antimicrobial spread. Current bacterial diagnosis methods identify pathogens or determine antibiotic resistance separately, necessitating multiple assays. There is an urgent need for tools that simultaneously identify infectious agents and their antibiotic resistance at the point of care (POC). We developed an integrated electrochemical chip-based biosensor for detecting enteropathogenic E. coli (EPEC), a major neonatal diarrheal pathogen, using an antibody against a virulence marker, termed EspB, and the ß-lactam resistance marker, ß-lactamase. A dual-channel microfabricated chip, bio-functionalized with a specific EspB monoclonal antibody, and nitrocefin, a ß -lactamase substrate was utilized. The chip facilitated electrochemical impedance spectroscopy (EIS)-based detection of EspB antigen and EspB-expressing bacteria. For ß-lactam resistance profiling, a second channel enabled differential-pulse voltammetric (DPV) measurement of hydrolyzed nitrocefin. EIS-based detection of EspB antigen was calibrated (LOD: 4.3 ng/mL ±1 and LOQ: 13.0 ng/mL ±3) as well as DPV-based detection of the antibiotic resistance marker, ß-lactamase (LOD: 3.6 ng/mL ±1.65 and LOQ: 10 ng/mL ±4). The integrated EIS and DPV biosensor was employed for the simultaneous detection of EspB-expressing and ß-lactamase-producing bacteria. The combined readout from both channels allowed the distinction between antibiotic-resistant and -sensitive pathogenic bacteria. The integrated electrochemical biosensor successfully achieved simultaneous, rapid detection of double positive EspB- and ß-lactamase-expressing bacteria. Such distinction enabled by a portable device within a short assay time and a simplified sample preparation, may be highly valuable in mitigating the spread of AMR. This new diagnostic tool holds promise for the development of POC devices in clinical diagnosis.


Subject(s)
Biosensing Techniques , beta-Lactamases , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Humans , beta-Lactamases/metabolism , Escherichia coli Infections/microbiology , Enteropathogenic Escherichia coli/isolation & purification , Enteropathogenic Escherichia coli/pathogenicity , Enteropathogenic Escherichia coli/drug effects , Dielectric Spectroscopy/instrumentation , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Equipment Design , Escherichia coli Proteins , Anti-Bacterial Agents/pharmacology , Cephalosporins
10.
Physiol Meas ; 45(5)2024 May 07.
Article in English | MEDLINE | ID: mdl-38604189

ABSTRACT

Objective. Bioimpedance spectroscopy (BIS) is a popular technique for the assessment of body composition in children and adults but has not found extensive use in babies and infants. This due primarily to technical difficulties of measurement in these groups. Although improvements in data modelling have, in part, mitigated this issue, the problem continues to yield unacceptably high rates of poor quality data. This study investigated an alternative data modelling procedure obviating issues associated with BIS measurements in babies and infants.Approach.BIS data are conventionally analysed according to the Cole model describing the impedance response of body tissues to an appliedACcurrent. This approach is susceptible to errors due to capacitive leakage errors of measurement at high frequency. The alternative is to model BIS data based on the resistance-frequency spectrum rather than the reactance-resistance Cole model thereby avoiding capacitive error impacts upon reactance measurements.Main results.The resistance-frequency approach allowed analysis of 100% of data files obtained from BIS measurements in 72 babies compared to 87% successful analyses with the Cole model. Resistance-frequency modelling error (percentage standard error of the estimate) was half that of the Cole method. Estimated resistances at zero and infinite frequency were used to predict body composition. Resistance-based prediction of fat-free mass (FFM) exhibited a 30% improvement in the two-standard deviation limits of agreement with reference FFM measured by air displacement plethysmography when compared to Cole model-based predictions.Significance.This study has demonstrated improvement in the analysis of BIS data based on the resistance frequency response rather than conventional Cole modelling. This approach is recommended for use where BIS data are compromised by high frequency capacitive leakage errors such as those obtained in babies and infants.


Subject(s)
Body Composition , Dielectric Spectroscopy , Electric Impedance , Humans , Infant , Dielectric Spectroscopy/methods , Infant, Newborn , Male , Female
11.
Sensors (Basel) ; 24(8)2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38676242

ABSTRACT

Foodborne pathogens are microbes present in food that cause serious illness when the contaminated food is consumed. Among these pathogens, Listeria monocytogenes is one of the most serious bacterial pathogens, and causes severe illness. The techniques currently used for L. monocytogenes detection are based on common molecular biology tools that are not easy to implement for field use in food production and distribution facilities. This work focuses on the efficacy of an electrochemical biosensor in detecting L. monocytogenes in chicken broth. The sensor is based on a nanostructured electrode modified with a bacteriophage as a bioreceptor which selectively detects L. monocytogenes using electrochemical impedance spectroscopy. The biosensing platform was able to reach a limit of detection of 55 CFU/mL in 1× PBS buffer and 10 CFU/mL in 1% diluted chicken broth. The biosensor demonstrated 83-98% recovery rates in buffer and 87-96% in chicken broth.


Subject(s)
Biosensing Techniques , Chickens , Dielectric Spectroscopy , Food Microbiology , Listeria monocytogenes , Listeria monocytogenes/isolation & purification , Biosensing Techniques/methods , Animals , Food Microbiology/methods , Electrodes
12.
Sensors (Basel) ; 24(8)2024 Apr 20.
Article in English | MEDLINE | ID: mdl-38676260

ABSTRACT

The study presents a promising approach to enzymatic kinetics using Electrochemical Impedance Spectroscopy (EIS) to assess fundamental parameters of modified enteropeptidases. Traditional methods for determining these parameters, while effective, often lack versatility and convenience, especially under varying environmental conditions. The use of EIS provides a novel approach that overcomes these limitations. The enteropeptidase underwent genetic modification through the introduction of single amino acid modifications to assess their effect on enzyme kinetics. However, according to the one-sample t-test results, the difference between the engineered enzymes and hEKL was not statistically significant by conventional criteria. The kinetic parameters were analyzed using fluorescence spectroscopy and EIS, which was found to be an effective tool for the real-time measurement of enzyme kinetics. The results obtained through EIS were not significantly different from those obtained through traditional fluorescence spectroscopy methods (p value >> 0.05). The study validates the use of EIS for measuring enzyme kinetics and provides insight into the effects of specific amino acid changes on enteropeptidase function. These findings have potential applications in biotechnology and biochemical research, suggesting a new method for rapidly assessing enzymatic activity.


Subject(s)
Dielectric Spectroscopy , Kinetics , Dielectric Spectroscopy/methods , Spectrometry, Fluorescence/methods , Biosensing Techniques/methods , Protein Engineering/methods
13.
ACS Appl Bio Mater ; 7(3): 2000-2011, 2024 Mar 18.
Article in English | MEDLINE | ID: mdl-38447196

ABSTRACT

Cell culture models of endothelial and epithelial barriers typically use porous membrane inserts (e.g., Transwell inserts) as a permeable substrate on which barrier cells are grown, often in coculture with other cell types on the opposite side of the membrane. Current methods to characterize barrier function in porous membrane inserts can disrupt the barrier or provide bulk measurements that cannot isolate barrier cell resistance alone. Electrical cell-substrate impedance sensing (ECIS) addresses these limitations, but its implementation on porous membrane inserts has been limited by costly manufacturing, low sensitivity, and lack of validation for barrier assessment. Here, we present porous membrane ECIS (PM-ECIS), a cost-effective method to adapt ECIS technology to porous substrate-based in vitro models. We demonstrate high fidelity patterning of electrodes on porous membranes that can be incorporated into well plates of a variety of sizes with excellent cell biocompatibility with mono- and coculture set ups. PM-ECIS provided sensitive, real-time measurement of isolated changes in endothelial cell barrier impedance with cell growth and barrier disruption. Barrier function characterized by PM-ECIS resistance correlated well with permeability coefficients obtained from simultaneous molecular tracer permeability assays performed on the same cultures, validating the device. Integration of ECIS into conventional porous cell culture inserts provides a versatile, sensitive, and automated alternative to current methods to measure barrier function in vitro, including molecular tracer assays and transepithelial/endothelial electrical resistance.


Subject(s)
Dielectric Spectroscopy , Endothelial Cells , Porosity , Endothelial Cells/metabolism , Coculture Techniques , Electrodes
14.
Mikrochim Acta ; 191(4): 182, 2024 03 07.
Article in English | MEDLINE | ID: mdl-38451377

ABSTRACT

The rapid fabrication is described of binary electrocatalyst based on a highly porous metal-organic framework with zirconium metal core (Zr-MOF) decorated over the graphitic carbon nitride (g-C3N4) nanosheets via facile ultrasonication method. It is used for the robust determination of antipsychotic drug chlorpromazine (CLP) from environmental samples. The electrochemical behaviour of 2D Zr-MOF@g-C3N4 was characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) studies. The crystalline and porous nature of the composite was characterized by XRD and SEM analysis. The functional groups and surface characteristics were investigated by FT-IR, Raman and XPS. The major electrochemical properties of the Zr-MOF@g-C3N4 composite towards CLP detection were analyzed by CV, chronocoulometric (CC), chronoamperometric (CA) and differential pulse voltammetry (DPV) techniques. The composite exhibits a low detection limit (LOD) of 2.45 nM with a linear range of 0.02 to 2.99 µM and attractive sensitivity for CLP. The sensor system shows higher selectivity towards the possible interferences of CLP drug and exhibits better repeatability and stability. Finally, the fabricated sensor system shows a high recovery range varying from 96.2 to 98.9% towards the real samples. The proposed electrochemical probe might be a promising alternative to the prevailing diagnostic tools for the detection of CLP.


Subject(s)
Antipsychotic Agents , Chlorpromazine , Spectroscopy, Fourier Transform Infrared , Dielectric Spectroscopy , Electrodes
15.
Eur J Pediatr ; 183(5): 2251-2256, 2024 May.
Article in English | MEDLINE | ID: mdl-38407589

ABSTRACT

The purpose of this study is to evaluate the intracellular and extracellular volume before and after anesthesia in order to ascertain their variations and determine the potential utility of this information in optimizing intraoperative fluid administration practices. A bioimpedance spectroscopy device (body composition monitor, BCM) was used to measure total body fluid volume, extracellular volume, and intracellular volume. BCM measurements were performed before and after general anesthesia in unselected healthy children and adolescents visiting the Pediatric Institute of Southern Switzerland for low-risk surgical procedures hydrated with an isotonic solution. In 100 children and adolescents aged 7.0 (4.8-11) years (median and interquartile range), the average total body water increased perioperatively with a delta value of 182 (0-383) mL/m2 from pre- to postoperatively, as well as the extracellular water content, which had a similar increase with a delta value of 169 (19-307) mL/m2. The changes in total body water and extracellular water content significantly correlated with the amount of fluids administered. The intracellular water content did not significantly change.   Conclusion: Intraoperative administration of isotonic solutions results in a significant fluid accumulation in low-risk schoolchildren during general anesthesia. The results suggest that children without major health problems undergoing short procedures do not need any perioperative intravenous fluid therapy, because they are allowed to take clear fluids up to 1 h prior anesthesia. In future studies, the use of BCM measurements has the potential to be valuable in guiding intraoperative fluid therapy. What is Known: • Most children who undergo common surgical interventions or investigations requiring anesthesia are nowadays hydrated at a rate of 1700 mL/m2/day with an isotonic solution. • The use bioimpedance spectroscopy for the assessment of fluid status in healthy children has already been successfully validated. • The bioimpedance spectroscopy is already currently widely used in various nephrological settings to calculate fluid overload and determine patient's optimal fluid status. What is New: • Routine intraoperative fluid administration results in a significant fluid accumulation during general anesthesia in low-risk surgical procedures. • This observation might be relevant for children and adolescents with conditions predisposing to fluid retention. • In future studies, the use of BCM measurements has the potential to be valuable in guiding intraoperative fluid therapy.


Subject(s)
Anesthesia, General , Body Composition , Fluid Therapy , Humans , Child , Pilot Projects , Male , Female , Anesthesia, General/methods , Adolescent , Child, Preschool , Fluid Therapy/methods , Dielectric Spectroscopy/methods , Body Water , Isotonic Solutions/administration & dosage , Electric Impedance , Switzerland
16.
Water Sci Technol ; 89(4): 904-914, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38423608

ABSTRACT

In this study, polyoxometalates (POMs) as a core-modifying material was used to fabricate the nanofiltration (NF) membrane on the polyvinylidene fluoride (PVDF) microfiltration membrane substrate via a novel interfacial polymerization (IP) method. The formation mechanism of the POMs-modified composite membrane was proposed. The separation and antifouling properties were further investigated. After cross-linking with POMs through the new IP reaction, the modified composite membrane showed improved hydrophilicity, water flux, and salt rejection. In the humic acid fouling experiment, the POMs-modified membrane exhibited the best antifouling performance, with a flux recovery rate of up to 91.3%. Electrochemical impedance spectroscopy was further used to investigate the antifouling performance of the membranes. Nyquist and Bode plots of the POMs-modified membranes showed no significant change before and after fouling compared to the PVDF membrane substrate, indicating reduced fouling attachment on the modified membrane, which was consistent with the fouling index and flux variation observed during the fouling experiment. Our findings provide a simple and valuable route for fabricating POMs-functionalized NF membranes with desirable separation and antifouling performance.


Subject(s)
Anions , Biofouling , Polyelectrolytes , Polyvinyls , Biofouling/prevention & control , Dielectric Spectroscopy , Fluorocarbon Polymers , Membranes, Artificial
17.
Biosens Bioelectron ; 252: 116041, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38401280

ABSTRACT

A novel electrical impedance spectroscopy-based method for non-destructive sensing of gene expression in living cells is presented. The approach used takes advantage of the robustness and responsiveness of electrical impedance spectroscopy and the highly specific and selective nature of DNA hybridization. The technique uses electrical impedance spectroscopy and gold nanoparticles functionalized with single-stranded DNA complementary to an mRNA of interest to provide reliable, real-time, and quantifiable data on gene expression in live cells. The system was validated by demonstrating specific detection of the uidA mRNA, which codes for the ß-glucuronidase (GUS) enzyme, in Solanum lycopersicum MsK8 cells. Gold nanoparticles were functionalized with single-stranded DNA oligonucleotides consisting of either a sequence complementary to uidA mRNA or an arbitrary sequence. The DNA-functionalized gold nanoparticles were mixed with cell suspensions, allowing the gold nanoparticles to penetrate into the cells. The impedance spectra of suspensions of cells with gold nanoparticles inserted within them were then studied. In suspensions of uidA-expressing cells and gold nanoparticles functionalized with the complementary single-stranded DNA oligonucleotide, the impedance magnitude in the frequency range of interest was significantly higher (146 %) in comparison to all other controls. Due to its highly selective nature, the methodology has the potential to be used as a precision agricultural sensing system for accurate and real-time detection of markers of stress, viral infection, disease, and normal physiological activities.


Subject(s)
Biosensing Techniques , Metal Nanoparticles , Gold/chemistry , DNA, Single-Stranded/genetics , Dielectric Spectroscopy , Metal Nanoparticles/chemistry , Biosensing Techniques/methods , DNA/genetics , RNA, Messenger , Gene Expression , Electric Impedance
18.
Sensors (Basel) ; 24(3)2024 Jan 28.
Article in English | MEDLINE | ID: mdl-38339574

ABSTRACT

This paper presents the development of a miniaturized sensor device for selective detection of pathogens, specifically Influenza A Influenza virus, as an enveloped virus is relatively vulnerable to damaging environmental impacts. In consideration of environmental factors such as humidity and temperature, this particular pathogen proves to be an ideal choice for our study. It falls into the category of pathogens that pose greater challenges due to their susceptibility. An impedance biosensor was integrated into an existing platform and effectively separated and detected high concentrations of airborne pathogens. Bio-functionalized hydrogel-based detectors were utilized to analyze virus-containing particles. The sensor device demonstrated high sensitivity and specificity when exposed to varying concentrations of Influenza A virus ranging from 0.5 to 50 µg/mL. The sensitivity of the device for a 0.5 µg/mL analyte concentration was measured to be 695 Ω· mL/µg. Integration of this pathogen detector into a compact-design air quality monitoring device could foster the advancement of personal exposure monitoring applications. The proposed sensor device offers a promising approach for real-time pathogen detection in complex environmental settings.


Subject(s)
Air Pollution , Biosensing Techniques , Dielectric Spectroscopy , Electric Impedance
19.
Nano Lett ; 24(7): 2234-2241, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38320294

ABSTRACT

Negative capacitance at low frequencies for spiking neurons was first demonstrated in 1941 (K. S. Cole) by using extracellular electrodes. The phenomenon subsequently was explained by using the Hodgkin-Huxley model and is due to the activity of voltage-gated potassium ion channels. We show that Escherichia coli (E. coli) biofilms exhibit significant stable negative capacitances at low frequencies when they experience a small DC bias voltage in electrical impedance spectroscopy experiments. Using a frequency domain Hodgkin-Huxley model, we characterize the conditions for the emergence of this feature and demonstrate that the negative capacitance exists only in biofilms containing living cells. Furthermore, we establish the importance of the voltage-gated potassium ion channel, Kch, using knock-down mutants. The experiments provide further evidence for voltage-gated ion channels in E. coli and a new, low-cost method to probe biofilm electrophysiology, e.g., to understand the efficacy of antibiotics. We expect that the majority of bacterial biofilms will demonstrate negative capacitances.


Subject(s)
Dielectric Spectroscopy , Escherichia coli , Neurons/physiology , Bacteria , Biofilms
20.
Biosensors (Basel) ; 14(2)2024 Feb 16.
Article in English | MEDLINE | ID: mdl-38392020

ABSTRACT

Here, we present the results of our the electrochemical aptasensing strategy for retinol binding protein-4 (RBP-4) detection based on a thiolated aptamer against RBP-4 and 6-mercaptohexanol (MCH) directly immobilized on a gold electrode surface. The most important parameters affecting the magnitude of the analytical signal generated were optimized: (i) the presence of magnesium ions in the immobilization and measurement buffer, (ii) the concentration of aptamer in the immobilization solution and (iii) its folding procedure. In this work, a systematic assessment of the electrochemical parameters related to the optimization of the sensing layer of the aptasensor was carried out (electron transfer coefficients (α), electron transfer rate constants (k0) and surface coverage of the thiolated aptamer probe (ΓApt)). Then, under the optimized conditions, the analytical response towards RBP-4 protein, in the presence of an Fe(CN)63-/4- redox couple in the supporting solution was assessed. The proposed electrochemical strategy allowed for RBP-4 detection in the concentration range between 100 and 1000 ng/mL with a limit of detection equal to 44 ng/mL based on electrochemical impedance spectroscopy (EIS). The specificity studies against other diabetes biomarkers, including vaspin and adiponectin, proved the selectivity of the proposed platform. These preliminary results will be used in the next step to miniaturize and test the sensor in real samples.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , Metal Nanoparticles , Biosensing Techniques/methods , Aptamers, Nucleotide/chemistry , Dielectric Spectroscopy/methods , Oxidation-Reduction , Gold/chemistry , Electrodes , Retinol-Binding Proteins , Electrochemical Techniques/methods , Limit of Detection , Metal Nanoparticles/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...