Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.973
Filter
1.
Medicine (Baltimore) ; 103(26): e38612, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38941392

ABSTRACT

RATIONALE: Complete dislodgement of a mechanical valve is extremely uncommon as a long-term issue after getting a substitute mitral valve, and this report details an incident of complete detachment of a mechanical valve. PATIENT CONCERNS: A 50-year-old woman, who underwent mitral mechanical valve replacement 2 decades earlier at another facility, was urgently admitted due to sudden cardiogenic shock. DIAGNOSES: Transthoracic echocardiograms revealed severe malfunction of the mitral valve prosthesis, characterized by significant mitral regurgitation and moderate pulmonary hypertension. Following the insertion of extracorporeal membrane oxygenation and an intra-aortic balloon pump, the hemodynamics stabilized. Coronary angiography displayed the prosthetic mitral valve ring and leaflet floating in the left atrium, as confirmed by preoperative real-time 3-dimensional transesophageal echocardiography. A complete separation of the prosthetic ring and leaflet from the suture ring was observed. INTERVENTIONS: The patient promptly underwent bioprosthetic mitral valve replacement. OUTCOMES: The patient's postoperative course was uneventful, leading to discharge in good condition. LESSONS: A crucial aspect is comprehending the structure of the prosthetic valve itself. The use of transthoracic echocardiography and real-time 3-dimensional transesophageal echocardiography provides additional structural and functional details, enhancing support for potential life-saving interventions. Echocardiography plays a significant role in evaluating the morphology and function of prosthetic valves.


Subject(s)
Heart Valve Prosthesis , Mitral Valve Insufficiency , Prosthesis Failure , Humans , Female , Middle Aged , Heart Valve Prosthesis/adverse effects , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/adverse effects , Echocardiography, Transesophageal , Shock, Cardiogenic/etiology , Echocardiography, Three-Dimensional/methods
2.
Echocardiography ; 41(6): e15822, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38853621

ABSTRACT

BACKGROUND: Balloon sizing (BS) has been used for device size selection in percutaneous atrial septal defect (ASD) closure. Due to its limitations, alternative imaging techniques like three-dimensional transesophageal echocardiography (3D-TEE) are valuable for guiding ASD device size selection during ASD closure procedures. The purpose of this study was to compare ASD sizing using measurements obtained from 3D-TEE to those utilizing the standard balloon sizing method. METHODS: We identified 53 patients with single secundum type ASD without PFO who underwent percutaneous closure at the Tehran Heart Center between 2019 and 2022. Balloon sizing was performed in all patients with the stop-flow technique, and the choice of device size was determined based on the sizing derived from BS. 3D-TEE imaging was performed before the intervention, and the ASD shape and quality of ASD rims were assessed. RESULTS: Among the 53 patients who underwent single ASD device closure, multiple 3D TEE measurements significantly correlated with balloon sizing results. This included defect area, perimeter, and diameter obtained from 3D-TEE images multi-planar reconstruction. ASD perimeter detected by 3D TEE had the best correlation with BS results. When divided by the shape of ASD, there was no significant difference between our 3D-images data and BS in round or oval-shaped ASDs. CONCLUSION: The 3D-TEE study is reliable for assessing ASD configurational characteristics in percutaneous device closure candidates. 3D-TEE has the potential to accurately determine the appropriate device size and reduce complications, costs, and procedural duration. Further research is needed to validate these findings and establish the role of 3D-TEE measurements in guiding the best treatment decisions for ASD closure.


Subject(s)
Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Heart Septal Defects, Atrial , Septal Occluder Device , Humans , Echocardiography, Transesophageal/methods , Echocardiography, Three-Dimensional/methods , Male , Heart Septal Defects, Atrial/surgery , Heart Septal Defects, Atrial/diagnostic imaging , Female , Adult , Middle Aged , Adolescent , Prosthesis Design , Cardiac Catheterization/methods , Reproducibility of Results , Young Adult
3.
Cardiol Clin ; 42(3): 351-360, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38910020

ABSTRACT

Echocardiography, in all its forms (transthoracic echocardiography [TTE], transesophageal echocardiography [TEE], and intracardiac echocardiography [ICE]), is pivotal for the evaluation, guidance, and follow-up of transcatheter tricuspid edge-to-edge repair (TV-TEER) therapies. Although two-dimensional (2D) echocardiography remains essential, three-dimensional (3D) echo with multiplanar reconstruction (MPR) has revolutionized the field of structural imaging. In addition, the advent of 3D ICE has added an important modality to the imaging toolbox, particularly helpful when intraprocedural TEE images are challenging. In this review, we provide a detailed, step-by-step approach for advanced echocardiographic guidance of TV-TEER using 3D MPR.


Subject(s)
Cardiac Catheterization , Echocardiography, Three-Dimensional , Tricuspid Valve Insufficiency , Tricuspid Valve , Humans , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Cardiac Catheterization/methods , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Ultrasonography, Interventional/methods , Echocardiography/methods
4.
Medicine (Baltimore) ; 103(21): e38206, 2024 May 24.
Article in English | MEDLINE | ID: mdl-38788025

ABSTRACT

OBJECTIVE: To evaluate left atrial volume and function in patients with paroxysmal atrial fibrillation (AF) combined with left atrial appendage thrombosis and patients with paroxysmal AF without left atrial appendage thrombosis by 3-dimensional speckle tracking imaging (3D-STI), and to explore the application value of this set of parameters in the evaluation of left atrial function in patients with paroxysmal AF. MATERIALS AND METHODS: A total of 40 patients with paroxysmal AF admitted from December 2018 to December 2020 were selected as the observation group. All patients with paroxysmal AF in the observation group underwent transesophageal echocardiography. According to the presence of left atrial appendage thrombosis, the patients were divided into the AF without thrombosis group (24 cases) and the AF with thrombosis group (16 cases). Thirty normal people were selected as control group who were chosen as having no heart-related disease. The left atrial volume parameters (Left atrial maximum volume LAVmax, Left atrial minimum volume LAVmin, Left atrial volume before atrial contraction LAVpre-A, Left atrial stroke volume LAEV), left atrial ejection fraction (LAEF) and left atrial strain parameters (Left atrial reservoir longitudinal strain LASr, Left atrial conduit longitudinal strain LAScd, Left atrial contraction longitudinal strain LASct, Left atrial reservoir circumferential strain LASr-c, Left atrial conduit circumferential strain LAScd-c, Left atrial contraction circumferential strain LASct-c) of the 3 groups were measured by 3D-STI. RESULTS: With the progression of paroxysmal AF, the left atrial volume increased, and the reservoir, conduit and contractile function were damaged. The left atrial volume continued to increase, and the reservoir, conduit and contractile function further decreased significantly in patients with AF combined with left atrial appendage thrombosis. LAEF was positively correlated with LASr and LASr_c. CONCLUSION: Real-time 3-dimensional spot tracking imaging (3D-STI) can evaluate the changes in left atrial volume and function in patients with paroxysmal AF, and has a certain reference value for clinical judgment of disease progression and prognosis.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Atrial Function, Left , Humans , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnostic imaging , Male , Female , Middle Aged , Atrial Function, Left/physiology , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Echocardiography, Three-Dimensional/methods , Heart Atria/diagnostic imaging , Heart Atria/physiopathology , Echocardiography, Transesophageal/methods , Aged , Thrombosis/diagnostic imaging , Thrombosis/etiology , Thrombosis/physiopathology
5.
Sci Rep ; 14(1): 11937, 2024 05 24.
Article in English | MEDLINE | ID: mdl-38789491

ABSTRACT

Transesophageal echocardiography (TEE) has been the preferred imaging modality to help guide left atrial appendage closure. Newer technologies such as the Nuvision 4D Intracardiac echocardiography (ICE) catheter allow for real-time 3D imaging of cardiac anatomy. There are no direct comparison studies for procedural imaging between TEE and 4D ICE. To evaluate the performance and safety of left atrial appendage (LAA) closure procedures with the Watchman FLX and Amulet, guided by the Nuvision 4D ICE Catheter. This retrospective observational analysis was conducted on institutional LAAO National Cardiovascular Data Registry from January 2022 to March 2023. Patients had undergone LAA closure procedures with the Watchman FLX or Amulet device guided by TEE or a 4D ICE Catheter. The primary outcome evaluated was successful LAAO device placement. A total of 121 patients underwent LAAO device placement with 46 (38.0%) patients guided by 4D ICE during LAAO implantation. The 4D ICE group had a shorter procedural time compared with TEE guidance. Post procedural 45-day TEE post implant was also comparable for both groups with no patients in either group having incomplete closure of the left atrial appendage and peri-device leak > 5 mm. No device related complications (device related access, stroke, or pericardial effusion) occurred in either group at follow-up. There was no significant difference in device implant success or post procedural outcomes at 45 days in either the TEE or 4D ICE group. However, there was a noticeable improvement in procedural time with the 4D ICE catheter.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Echocardiography, Transesophageal , Humans , Atrial Appendage/surgery , Atrial Appendage/diagnostic imaging , Male , Female , Aged , Retrospective Studies , Echocardiography, Transesophageal/methods , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnostic imaging , Cardiac Catheterization/methods , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Aged, 80 and over , Echocardiography, Three-Dimensional/methods , Middle Aged , Echocardiography/methods , Treatment Outcome , Cardiac Catheters , Left Atrial Appendage Closure
6.
Medicine (Baltimore) ; 103(18): e38058, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38701248

ABSTRACT

To evaluate the right atrial function in patients with 3-branch coronary artery disease (TBCAD) without myocardial infarction by 2D speckle tracking echocardiography (2D-STE) combined with real-time 3-dimensional echocardiography (RT-3DE). Fifty-six patients admitted to our hospital without myocardial infarction with TBCAD were selected. We divided them into 2 groups according to the coronary angiography results: 28 patients in group B (the rate of stenosis is 50% ~< 75%); 28 patients in group C (the rate of stenosis is ≥75%); in addition, 30 healthy volunteers were screened as group A. All subjects underwent RT-3DE to obtain the right atrial volume (RAVmax, RAVmin, and RAVp), and then we calculated the right atrial passive and active ejection fraction (RAPEF, RAAEF), and maximum volume index (RAVImax). In addition, to measure the strain rates (RASRs, RASRe, RASRa) of the right atrium during systole, early diastole, and late diastole, 2D-STE was applied. Correlations between the 2D-STE parameters and the results of N-terminal pro-brain natriuretic peptide (NT-proBNP) and Gensini scores were analyzed by Pearson linear analysis. Compared with group A, RAPEF and RASRe were reduced, while RAAEF and RASRa were elevated in group B (P < .05). RAPEF, RASRs, RASRe, and RASRa were decreased compared with groups A and B, while RAVmax, RAVmin, RAVp, RAVImax, and RAAEF were increased in group C (P < .05). There was a significant correlation between 2D-STE parameters and the results of NT-proBNP and Gensini scores (P < .05). The storage, conduit, and pump functions of the right atrium are reduced in patients with 3-branch coronary artery disease without myocardial infarction; 2D-STE combined with RT-3DE is valuable in the evaluation of the right atrium in patients with coronary artery disease.


Subject(s)
Coronary Artery Disease , Echocardiography, Three-Dimensional , Heart Atria , Natriuretic Peptide, Brain , Humans , Male , Echocardiography, Three-Dimensional/methods , Female , Middle Aged , Coronary Artery Disease/physiopathology , Coronary Artery Disease/diagnostic imaging , Natriuretic Peptide, Brain/blood , Heart Atria/diagnostic imaging , Heart Atria/physiopathology , Aged , Peptide Fragments/blood , Atrial Function, Right/physiology , Echocardiography/methods , Coronary Angiography/methods
7.
PLoS One ; 19(4): e0302123, 2024.
Article in English | MEDLINE | ID: mdl-38630708

ABSTRACT

BACKGROUND: Fetal two-dimensional speckle tracking echocardiography (2D-STE) is an emerging technique for assessing fetal cardiac function by measuring global longitudinal strain. Alterations in global longitudinal strain may serve as early indicator of pregnancy complications, making 2D-STE a potentially valuable tool for early detection. Early detection can facilitate timely interventions to reduce fetal and maternal morbidity and mortality. Therefore, the aim of this study was to investigate the feasibility of performing 2D-STE at 16 weeks gestational age. METHODS: This pilot study utilized 50 ultrasound clips of the fetal four-chamber view recorded between 15+5 and 16+2 weeks gestational age from a prospective cohort study. A strict protocol assessed three parameters essential for 2D-STE analysis: fetal four-chamber view ultrasound clip quality, region of interest, and frame rates. Two independent researchers measured global longitudinal strain in all adequate fetal four-chamber view ultrasound clips to determine inter- and intra-operator reliability. RESULTS: Out of the 50 ultrasound clips, 37 (74%) were feasible for 2D-STE analysis. The inter-operator reliability for global longitudinal strain measurements of the left and right ventricles was moderate (ICC of 0.64 and 0.74, respectively), while the intra-operator reliability was good (ICC of 0.76 and 0.79, respectively). CONCLUSIONS: Our findings demonstrate that fetal 2D-STE analysis at 16 weeks gestational age is feasible when adhering to a strict protocol. However, further improvements are necessary to enhance the inter- and intra-operator reliability of 2D-STE at this gestational age.


Subject(s)
Echocardiography, Three-Dimensional , Echocardiography , Pregnancy , Female , Humans , Gestational Age , Pilot Projects , Reproducibility of Results , Feasibility Studies , Prospective Studies , Echocardiography/methods , Heart Ventricles , Echocardiography, Three-Dimensional/methods
8.
J Cardiothorac Vasc Anesth ; 38(7): 1460-1466, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38580474

ABSTRACT

OBJECTIVES: This study aimed to evaluate the accuracy of identifying the true aortic valve (AV) annulus using 2-dimensional (2D) echocardiography, with the goal of highlighting potential misidentification issues in clinical practice. DESIGN: An observational study employing 3-dimensional (3D) datasets to generate 2D images of the AV annulus for analysis. SETTING: The study was conducted in an academic medical center. PARTICIPANTS: Three-dimensional transesophageal echocardiography datasets were obtained from 11 patients with normal AV and aortic root anatomies undergoing coronary artery bypass surgery. Attending anesthesiologists certified by the National Board of Echocardiography (NBE) were approached subsequently to participate in this study. INTERVENTIONS: Two images per patient were generated from 3D datasets, reflecting the mid-esophageal long-axis view of the AV, a true AV annulus image, and an off-axis image. A survey was distributed to NBE-certified perioperative echocardiographers across 12 academic institutions to identify the true AV annulus from these images. MEASUREMENTS AND MAIN RESULTS: The survey, completed by 45 qualified respondents, revealed a significant misidentification rate of the true AV annulus, with only 36.8% of responses correctly identifying it. The rate of correct identification varied across image sets, with 44.4% of participants unable to correctly identify any true AV annulus image. CONCLUSIONS: The study highlighted the limitations of 2D echocardiography in accurately identifying the true AV annulus in complex 3D structures like the aortic root. The findings suggest a need for greater reliance on advanced imaging modalities, such as 3D echocardiography, to improve accuracy in clinical practice.


Subject(s)
Aortic Valve , Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Echocardiography, Three-Dimensional/methods , Echocardiography, Three-Dimensional/standards , Echocardiography, Transesophageal/methods , Echocardiography, Transesophageal/standards , Male , Female , Aged , Middle Aged , Echocardiography/methods , Echocardiography/standards
9.
J Clin Ultrasound ; 52(5): 600-607, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38581157

ABSTRACT

INTRODUCTION: Similarly to the ventricles, the atria are under sympathetic/parasympathetic neural regulation. Accordingly, correlations were investigated between Ewing's standard cardiovascular reflex tests (SCRTs) and three-dimensional speckle-tracking echocardiography (3DSTE)-derived right atrial (RA) volumes and strains in healthy subjects. MATERIALS AND METHODS: The study comprised 45 healthy adults, but 5 subjects were excluded due to inferior image quality for 3DSTE-derived RA assessments. The remaining 40 individuals being in sinus rhythm had a mean age of 35.1 ± 3.5 years (20 men). Two-dimensional, Doppler, 3DSTE and SCRTs were performed in all cases. RESULTS: RA maximum volume and total and passive RA stroke volumes correlated with the Valsalva ratio. Active RA stroke volume and emptying fraction showed correlations with 30/15 ratio. Peak global and mean segmental RA circumferential (CS) and longitudinal strains (LS) showed correlation with the Valsalva ratio. At atrial contraction, global RA-LS and mean segmental RA-CS showed correlations with the Valsalva ratio. Moreover, mean segmental RA-CS correlated with 30/15 ratio and mean segmental RA radial strain showed correlations with systolic blood pressure in response to standing. Autonomic neuropathy score correlated with peak global RA-LS. CONCLUSIONS: Autonomic function parameters have significant associations with specific RA functions in healthy adults, making the latter possible indicators of autonomic dysregulation.


Subject(s)
Atrial Function, Right , Echocardiography, Three-Dimensional , Heart Atria , Humans , Echocardiography, Three-Dimensional/methods , Male , Female , Adult , Heart Atria/diagnostic imaging , Heart Atria/physiopathology , Atrial Function, Right/physiology , Autonomic Nervous System/diagnostic imaging , Autonomic Nervous System/physiopathology , Reference Values , Healthy Volunteers
10.
J Cardiothorac Vasc Anesth ; 38(7): 1467-1476, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38627172

ABSTRACT

OBJECTIVE: To assess the intraoperative use of 3-dimensional transesophageal echocardiography (3D TEE) in cardiac surgical centers, the authors created a survey aimed at evaluating the availability of equipment and the use of 3D TEE for specific surgical and interventional procedures and single-image modalities. The respondents were asked to identify the perceived impact on patient management and current limitations to its routine use. DESIGN: A multiple choice 25-question online survey submitted to the members of the European Association of Cardiothoracic Anesthesia and Intensive Care (EACTAIC) on December 6, 2021, and closed on January 31, 2022. SETTING: An online survey. PARTICIPANTS: Registered EACTAIC members in 2021. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: A total of 239 respondents from 44 different countries took part in the survey (27% of the total 903 EACTAIC members). Most respondents (59%) were TEE-certified by the National Board of Echocardiography, European Association of Cardiovascular Imaging (EACVI/EACTAIC), or had a national certificate. Of the respondents, 68% had no formal 3D TEE training. Eight percent of respondents had no 3D machines, whereas 40% had one for each operating room, and 33% had only one for the entire operating room block. 3D TEE was performed most frequently in more than 67% of cases for mitral valve surgery, and in more than 54% of cases for mitral and tricuspid clips, aortic valve, tricuspid valve, and aortic surgery. CONCLUSION: Current guidelines suggest integrating 3D TEE into all comprehensive examinations. The authors' survey reported that intraoperative 3D TEE was used in the majority of mitral valve surgery and only one-half of the other valve surgeries and transcatheter procedures. Its use may be explained by the availability of 3D machines, trained personnel, and limited time to perform TEE in the operating room. Educational initiatives for training in 3D TEE may further increase its routine use.


Subject(s)
Cardiac Surgical Procedures , Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Humans , Echocardiography, Transesophageal/methods , Echocardiography, Three-Dimensional/methods , Cardiac Surgical Procedures/methods , Surveys and Questionnaires , Europe , Anesthesia, Cardiac Procedures/methods , Critical Care/methods , Societies, Medical , Monitoring, Intraoperative/methods
13.
Echocardiography ; 41(5): e15823, 2024 May.
Article in English | MEDLINE | ID: mdl-38678585

ABSTRACT

The morphologic features of the multiple atrial septal defects assessed by TTE-based 3D imaging were similar to those by 3D-TEE. TTE-based 3D model had excellent visibility, allowing observation of 3D structure of the rims of the defects. It may be useful method for assessment of the multiple atrial septal defects.


Subject(s)
Echocardiography, Three-Dimensional , Heart Septal Defects, Atrial , Vena Cava, Inferior , Humans , Heart Septal Defects, Atrial/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Vena Cava, Inferior/diagnostic imaging , Female , Male , Adult
14.
BMC Med Imaging ; 24(1): 61, 2024 Mar 13.
Article in English | MEDLINE | ID: mdl-38481130

ABSTRACT

OBJECTIVE: The paper aimed to improve the accuracy limitations of traditional two-dimensional ultrasound and surgical procedures in the diagnosis and management of congenital heart disease (chd), and to improve the diagnostic and therapeutic level of chd. METHOD: This article first collected patient data through real-time imaging and body surface probes, and then diagnosed 150 patients using three-dimensional echocardiography. In order to verify the effectiveness of the combination therapy, 60 confirmed patients were divided into a control group and an experimental group. The control group received conventional two-dimensional ultrasound and surgical treatment, while the experimental group received three-dimensional ultrasound and image guided surgical treatment. RESULT: In the second diagnosis, the diagnostic accuracy of type 1, type 2, and type 3 in the control group was 84.21%, 84.02%, and 83.38%, respectively. The diagnostic accuracy rates of type 1, type 2, and type 3 in the experimental group were 92.73%, 92.82%, and 92.83%, respectively. In the control group, 2 males and 1 female experienced heart failure after surgery. However, in the experimental group, 0 males and 0 females experienced heart failure after surgery. CONCLUSION: The combination of three-dimensional echocardiography and image guided surgery can improve diagnostic accuracy and surgical treatment effectiveness, thereby reducing risks and complications, and improving surgical success rate.


Subject(s)
Echocardiography, Three-Dimensional , Heart Defects, Congenital , Heart Failure , Surgery, Computer-Assisted , Male , Humans , Female , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery , Echocardiography, Three-Dimensional/methods , Ultrasonography
15.
Early Hum Dev ; 191: 105985, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38513546

ABSTRACT

BACKGROUND: Increased left atrial volume (LAV) is a marker of cardiovascular risk. Echocardiography standards to assess LAV in adults and children are the biplane area-length method (AL) and method of disks (MOD). LAV in neonatology is usually derived as M-mode ratio between the LA and the Aorta (LAAo). The aim of this study is to determine feasibility and reliability of these methods in neonatal clinical practice. METHODS: Clinically indicated echocardiograms in neonatal intensive care patients were retrospectively analyzed. Feasibility was determined with an image quality score describing insonation angle, foreshortening and wall clarity. Reliability was determined with Bland-Altman and correlation coefficient analysis of intra- and inter-observer measurements. RESULTS: 104 infants ranging from 23 to 39 weeks gestation were included. The feasibility of LAAo, AL and MOD was comparable (median image score 4 out of 6 points). Linear regression between AL and MOD was excellent (R2 0.99). LAAo best-fit with MOD was reached with curve-linear regression (R2 0.28) whereby a LAAo of 1.60 correlated with 1.24 ml/kg, but with a wide 95 % CI. The correlation coefficient within and between observers for LAAo, biplane AL, biplane MOD and monoplane MOD was 0.93 (0.87-0.96), 0.98 (0.96-0.99), 0.98 (0.96-0.99), 0.99 (0.97-0.99) and 0.58 (0.11-0.81), 0.75 (0.44-0.89), 0.92 (0.88-0.98), 0.96 (0.88-0.98) respectively. CONCLUSION: All methods were equally feasible and reliable when repeated by the same observer, but LAAo reliability was poor when repeated by a different observer. Biplane MOD was the most reliable and thus recommended in neonatal practice. Monoplane MOD performed well and could be considered as alternative but might be less accurate.


Subject(s)
Echocardiography, Three-Dimensional , Adult , Child , Infant, Newborn , Humans , Echocardiography, Three-Dimensional/methods , Reproducibility of Results , Intensive Care, Neonatal , Retrospective Studies , Heart Atria/diagnostic imaging
16.
Echocardiography ; 41(3): e15785, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38527004

ABSTRACT

BACKGROUND: Trans-catheter mitral valve replacement (TMVR) procedures had emerged as an alternative solution for patients who are at high risk for mitral valve surgery. Although cardiac computed tomography (CT) remains the standard method for procedural planning, there is no full agreement on the best systolic phase for quantitation of the neoLVOT. Furthermore, a new three-dimensional trans-esophageal echocardiography (3DTEE) based software was developed to serve as filter and or an alternative for patients who cannot have CT due to any contraindication. AIM: To determine the systolic phase of the cardiac cycle that shows the narrowest NeoLVOT area in order to standardize the way of using these software and then to validate the 3DTEE-based software against the CT-based one as a gold standard, in mitral valve annulus (MA) and NeoLVOT assessment. METHODS: A single center, observational, retrospective study. Initially, a sample of 20 patients (age 62 ± 4 years, 70% men) had CT-based analysis at mid-diastole (80%), early-systole (10%), mid-systole (20%), late-systole (30%-40%), in order to detect the best systolic phase at which the neoLVOT area is the narrowest after TMVR. Then, the end systolic phase was standardized for the analysis of 49 patients (age 57 ± 6 years, 60% men), using both the commercially available CT-based software and the newly available 3DTEE-based software (3mensio Structural Heart, Pie Medical Imaging, The Netherlands). The 3DTEE derived parameters were compared with the gold standard CT-based measurements. RESULTS: The neoLVOT area was significantly narrower at end-systole (224 ± 62 mm2), compared to early-systole (299 ± 70 mm2) and mid-systole (261 ± 75 mm2), (p = .005). Excellent correlation was found between 3DTEE and CT measurements for MA AP diameter (r = .96), IC diameter (r = .92), MA area (r = .96), MA perimeter (r = .94) and NeoLVOT area (r = .96), (all p-values < .0001). Virtual valve sizing was based on annulus measurement and was identical between CT and 3DTEE. Interobserver and intraobserver agreements were excellent for all the measurements with ICCs > .80. CONCLUSIONS: End-systole is the phase that shows the narrowest neoLVOT and hence should be the standard phase used during the analysis. The 3DTEE based analysis using this new software is reliable compared to the CT-based analysis and can be serve as an alternative analysis tool in patients who cannot have CT for any clinical contraindication or as a screening test and/or filter for all patients before proceeding to a detailed CT scan.


Subject(s)
Echocardiography, Three-Dimensional , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aged , Female , Humans , Male , Middle Aged , Catheters , Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Heart Valve Prosthesis Implantation/methods , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Reference Standards , Reproducibility of Results , Retrospective Studies
17.
Echocardiography ; 41(3): e15798, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38516863

ABSTRACT

Editing of 3D raw images acquired during transesophageal echocardiography could be similar to the post processing of raw images with digital software used in photography. 3D image editing in echocardiography is often underestimated in clinical practice, and people are satisfied with the first 3D image they are able to obtain during transesophageal examination. In fact, it is often believed to represent solely an aesthetic addition that does not change the information already obtained with 2D and baseline 3D. In reality, it represents a crucial moment to better understand the mechanisms of mitral pathology, avoiding artifacts and misjudgments. The importance of acquiring raw 3D images of the valve having all the necessary information (ring, the leaflet in toto, the right frame rate) allows us then to edit them making them more beautiful and clearer from the point of view of the information received. Nevertheless, by exclusively acquiring a raw 3D with all the necessary information, we can quickly finish the transesophageal examination, reducing its duration and discomfort for the patient, as well as the inherent risk of complications related to the procedure per se.


Subject(s)
Echocardiography, Three-Dimensional , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Echocardiography/methods , Echocardiography, Transesophageal/methods , Photography
18.
J Am Soc Echocardiogr ; 37(6): 591-598, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38522488

ABSTRACT

BACKGROUND: Echocardiographic grading of mitral regurgitation (MR) in mitral valve prolapse (MVP) is challenging. Three-dimensional (3D) vena contracta area (VCA) has been proposed as a valuable method. However, data defining the cutoff values of severity and validation in the subset of patients with MVP are scarce. The aim of this study was to validate the 3D VCA by 3D color-Doppler transesophageal echocardiography (TEE) in patients with MVP and to define the cutoff values of severity grading. The secondary aim was to compare 3D VCA to the effective regurgitant orifice area estimation by proximal isovelocity surface area (EROA-PISA) method. METHODS: A total of 1,138 patients with at least moderate MR who underwent TEE were included. Three-dimensional VCA was measured, and the cutoff value and area under the curve (AUC) for the prediction of severe MR were estimated by receiver operating characteristic curve using a guideline-suggested multiparametric approach as the reference standard. In a subgroup of patients, 3D regurgitant volume (RV) and 3D fraction were calculated from mitral and left ventricular outflow tract stroke volumes to further validate 3D VCA against a 3D volumetric reference standard. RESULTS: The optimal 3D VCA cutoff value for predicting severe MR was 0.45 cm2 (specificity, 0.87; sensitivity, 0.90) with an AUC of 0.95 using a multiparametric approach as reference. Three-dimensional VCA had a good linear correlation with EROA-PISA (r = 0.62, P < .05) with larger values compared to EROA-PISA (0.63 cm2 vs 0.44 cm2, P < .05). A cutoff of 0.50 cm2 (AUC of 0.84; sensitivity, 0.78; specificity, 0.78) predicts an EROA-PISA of 0.40 cm2. Three-dimensional VCA had a good linear correlation with 3D RV (r = 0.56, P < .01), with an AUC of 0.86 to predict a 3D fraction >50%. CONCLUSIONS: The present study suggests 0.45 cm2 as the best cutoff value of 3D VCA to define severe MR in patients with MVP, showing an optimal agreement with the reference standard multiparametric approach and 3D RV.


Subject(s)
Echocardiography, Three-Dimensional , Mitral Valve Insufficiency , Mitral Valve Prolapse , Severity of Illness Index , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Echocardiography, Three-Dimensional/methods , Female , Male , Mitral Valve Prolapse/complications , Mitral Valve Prolapse/diagnostic imaging , Mitral Valve Prolapse/physiopathology , Middle Aged , Aged , Echocardiography, Transesophageal/methods , Echocardiography, Doppler, Color/methods , Reproducibility of Results , Mitral Valve/diagnostic imaging , ROC Curve , Retrospective Studies
20.
J Heart Lung Transplant ; 43(7): 1183-1187, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38508504

ABSTRACT

Three-dimensional (3D) echocardiography-derived right ventricular (RV) ejection fraction (EF) and global longitudinal strain (GLS) are valuable RV functional markers; nevertheless, they are substantially load-dependent. Global myocardial work index (GMWI) is a novel parameter calculated by the area of the RV pressure-strain loop. By adjusting myocardial deformation to instantaneous pressure, it may reflect contractility. To test this hypothesis, we enrolled 60 patients who underwent RV pressure-conductance catheterization to determine load-independent markers of RV contractility and ventriculo-arterial coupling. Detailed 3D echocardiography was also performed, and we calculated RV EF, RV GLS, and using the RV pressure trace curve, RV GWMI. While neither RV EF nor GLS correlated with Ees, GMWI strongly correlated with Ees. In contrast, RV EF and GLS showed a relationship with Ees/Ea. By dividing the population based on their Reveal Lite 2 risk classification, different characteristics were seen among the subgroups. RV GMWI may emerge as a useful clinical tool for risk stratification and follow-up in patients with RV dysfunction.


Subject(s)
Echocardiography, Three-Dimensional , Myocardial Contraction , Stroke Volume , Ventricular Function, Right , Humans , Male , Female , Myocardial Contraction/physiology , Middle Aged , Ventricular Function, Right/physiology , Echocardiography, Three-Dimensional/methods , Stroke Volume/physiology , Ventricular Dysfunction, Right/physiopathology , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Pressure/physiology , Heart Ventricles/physiopathology , Heart Ventricles/diagnostic imaging , Cardiac Catheterization , Aged , Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...