Skin Res Technol ; 30(5): e13740, 2024 May.
Article in English | MEDLINE | ID: mdl-38720488

ABSTRACT

BACKGROUND: The human nail has a three-layered structure. Although it would be useful to quantitatively evaluate the changes in deformability of the nail due to various surface treatments, few studies have been conducted. METHODS: The effects of two types of surface treatment-a chemically acting nail softener and a physically acting nail strengthener-on the deformability of human fingernails were investigated. The Young's modulus of each plate of the nail samples before and after softening treatment was determined by nanoindentation. The Young's modulus of the strengthener was determined by conducting a three-point bending test on a polyethylene sheet coated with the strengthener. RESULTS: Young's modulus decreased in order from the top plate against the softening treatment time, and the structural elasticity for bending deformation (SEB) of the nail sample, which expresses the deformability against bending deformation independent of its external dimensions, decreased to 60% after 6 h of treatment. The Young's modulus of the nail strengthener was 244.5 MPa, which is less than 10% of the SEB of the nail. When the nail strengthener was applied to the nail surface, the SEB decreased to 73%, whereas the flexural rigidity increased to 117%. CONCLUSION: Changes in nail deformability caused by various surface treatments for softening and hardening were quantitatively evaluated successfully.


Subject(s)
Elastic Modulus , Nails , Surface Properties , Humans , Elastic Modulus/physiology , Nails/physiology , Female , Elasticity/physiology , Adult
2.
J Refract Surg ; 40(5): e344-e352, 2024 May.
Article in English | MEDLINE | ID: mdl-38717086

ABSTRACT

PURPOSE: To compare the effects of three common refractive surgeries on corneal biomechanics. METHODS: Two hundred seven patients who had refractive surgery were included in this study, of whom 65 received transepithelial photorefractive keratectomy (tPRK), 73 received femtosecond laser-assisted laser in situ keratomileusis (FSLASIK), and 69 received small incision lenticule extraction (SMILE). Each patient had biomechanical measurements using the Corvis ST (Oculus Optikgeräte GmbH) preoperatively and at 3 and 6 months postoperatively. The measurements included five parameters expected to be associated with corneal biomechanics: deformation amplitude ratio at 2 mm (DAR2), integrated inverse radius (IIR), stiffness parameter at first applanation (SP-A1), highest concavity time (HCT), and the updated stress-strain index (SSIv2). The variations in these parameters postoperatively among the three surgeries, and their relationship with corneal thickness (CCT) and intraocular pressure measured by the Dynamic Contour Tonometer (DCT-IOP) were analyzed. RESULTS: SP-A1 decreased significantly from preoperatively to 3 months postoperatively in all three groups, whereas DAR2 and IIR increased significantly, all indicating stiffness losses. Between 3 and 6 months postoperatively, the results were inconsistent, with DAR2 decreasing (indicating stiffness increases) and IIR increasing (denoting stiffness decreases) in the FS-LASIK and SMILE groups. The decrease in SSIv2 (the only measure of corneal material stiffness) postoperatively was comparatively less pronounced at both 3 and 6 months postoperatively. On the other hand, HCT remained generally stable after all three surgeries. Unlike DAR2, IIR, and SP-A1, the changes postoperatively in stiffness parameters HCT and SSIv2 were independent of the corresponding changes in both DCT-IOP and CCT. CONCLUSIONS: Among the stiffness parameters considered, SSIv2 was not correlated with CCT or DCT-IOP, and holds promise for representing the corneal material stiffness and how it remains largely unaffected by refractive surgeries. Overall, FS-LASIK had the most significant impact on corneal stiffness, followed by SMILE, and finally tPRK. [J Refract Surg. 2024;40(5):e344-e352.].


Subject(s)
Cornea , Elasticity , Intraocular Pressure , Keratomileusis, Laser In Situ , Lasers, Excimer , Myopia , Humans , Cornea/physiopathology , Cornea/surgery , Adult , Female , Male , Biomechanical Phenomena , Lasers, Excimer/therapeutic use , Keratomileusis, Laser In Situ/methods , Young Adult , Elasticity/physiology , Myopia/surgery , Myopia/physiopathology , Intraocular Pressure/physiology , Photorefractive Keratectomy/methods , Visual Acuity/physiology , Refraction, Ocular/physiology , Middle Aged , Prospective Studies , Corneal Surgery, Laser/methods , Corneal Topography
3.
Respir Physiol Neurobiol ; 325: 104264, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38599345

ABSTRACT

Eight pig tracheal strips were stimulated to contract with log increments of methacholine from 10-8 to 10-5 M. For each strip, the concentration-response was repeated four times in a randomized order to measure isometric force, isotonic shortening against a load corresponding to either 5 or 10 % of a reference force, and average force, stiffness, elastance and resistance over one cycle while the strip length was oscillating sinusoidally by 5 % at 0.2 Hz. For each readout, the logEC50 was calculated and compared. Isotonic shortening with a 5 % load had the lowest logEC50 (-7.13), yielding a greater sensitivity than any other contractile readout (p<0.05). It was followed by isotonic shortening with a 10 % load (-6.66), elastance (-6.46), stiffness (-6.46), resistance (-6.38), isometric force (-6.32), and average force (-6.30). Some of these differences were significant. For example, the EC50 with the average force was 44 % greater than with the elastance (p=0.001). The methacholine sensitivity is thus affected by the contractile readout being measured.


Subject(s)
Bronchoconstrictor Agents , Methacholine Chloride , Muscle, Smooth , Trachea , Animals , Muscle, Smooth/physiology , Muscle, Smooth/drug effects , Methacholine Chloride/pharmacology , Swine , Trachea/physiology , Trachea/drug effects , Bronchoconstrictor Agents/pharmacology , Muscle Contraction/physiology , Muscle Contraction/drug effects , Dose-Response Relationship, Drug , Elasticity/physiology , Isometric Contraction/physiology , Isometric Contraction/drug effects
4.
J Glaucoma ; 33(5): 334-339, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38194297

ABSTRACT

PRCIS: Corneal hysteresis (CH) and pulsatile ocular blood volume (POBV) were significantly lower in the eye with greater damage in asymmetric glaucoma, without a difference in intraocular pressure (IOP) or central corneal thickness (CCT), and no difference in elastic parameters. OBJECTIVE: To compare biomechanical and vascular metrics between the eyes of patients with asymmetric glaucoma (ASYMM) and those with symmetric glaucoma (SYMM). PATIENTS AND METHODS: Forty-five patients were prospectively recruited and divided into ASYMM, defined as cup-to-disc (C/D) ratio difference >0.1 between eyes and SYMM, with C/D difference ≤0.1. For ASYMM, the smaller C/D was defined as the best eye ("best") and the fellow eye was defined as the worst eye ("worse"). All metrics were subtracted as "worse" minus "best," including the viscoelastic parameter CH, and elastic parameters from the Corvis ST, including stiffness parameter at first applanation, stiffness parameter at highest concavity, integrated inverse radius, deformation amplitude ratio, IOP, CCT, mean deviation (MD), ganglion cell complex (GCC), and POBV were included. Paired t tests were performed between eyes in both groups. Statistical analyses were performed with SAS using a significance threshold of P <0.05. RESULTS: For ASYMM (16 patients), "worse" showed significantly lower CH (-0.76 ± 1.22), POBV (-0.38 ± 0.305), MD (-3.66 ± 6.55), and GCC (-7.9 ± 12.2) compared with "best." No other parameters were significantly different. For SYMM (29 patients), there were no significantly different metrics between eyes. CONCLUSIONS: Lower CH, POBV, GCC, and worse MD were associated with greater glaucomatous damage in asymmetric glaucoma without a difference in IOP or CCT. Lower CH and GCC are consistent with previous studies. POBV, a new clinical parameter that may indicate reduced blood flow, is also associated with greater damage.


Subject(s)
Cornea , Intraocular Pressure , Tonometry, Ocular , Visual Fields , Humans , Intraocular Pressure/physiology , Female , Male , Prospective Studies , Middle Aged , Biomechanical Phenomena , Cornea/physiopathology , Aged , Visual Fields/physiology , Retinal Ganglion Cells/pathology , Elasticity/physiology , Optic Disk/blood supply , Glaucoma, Open-Angle/physiopathology , Glaucoma, Open-Angle/diagnosis , Glaucoma/physiopathology , Nerve Fibers/pathology , Optic Nerve Diseases/physiopathology , Optic Nerve Diseases/diagnosis
5.
Graefes Arch Clin Exp Ophthalmol ; 262(6): 1795-1803, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38285248

ABSTRACT

PURPOSE: Recent evidence suggests that venous congestion at the vortex vein significantly contributes to the development of central serous chorioretinopathy (CSCR), and sclera is observed to be thicker in affected eyes. This study aims to investigate whether eyes with CSCR exhibit stiff corneas, measured using Corneal Visualization Scheimflug Technology (Corvis ST), which may serve as an indicator of scleral stiffness. METHODS: This retrospective case-control study comprises 52 eyes from 33 patients diagnosed with CSCR and 52 eyes from 32 normal controls without CSCR. We compared biomechanical parameters measured with Corvis ST and anterior scleral thickness measured using anterior segment swept-source optical coherence tomography between the two groups. RESULTS: Age, sex, axial length, intraocular pressure, and central corneal thickness showed no significant differences between the two groups (p > 0.05, linear mixed model). Three biomechanical parameters-peak distance, maximum deflection amplitude, and integrated inverse radius-indicated less deformability in CSCR eyes compared to control eyes. The stress-strain index (SSI), a measure of stiffness, and anterior scleral thickness (AST) at temporal and nasal points were significantly higher in the CSCR eyes. SSI and AST were not correlated, yet both were significantly and independently associated with CSCR in a multivariate logistic regression model. CONCLUSIONS: Eyes affected by CSCR have stiffer corneas, irrespective of thicker scleral thickness. This suggests that stiffer sclera may play a role in the pathogenesis of CSCR.


Subject(s)
Central Serous Chorioretinopathy , Cornea , Tomography, Optical Coherence , Humans , Central Serous Chorioretinopathy/physiopathology , Central Serous Chorioretinopathy/diagnosis , Male , Female , Retrospective Studies , Tomography, Optical Coherence/methods , Middle Aged , Biomechanical Phenomena , Cornea/physiopathology , Cornea/diagnostic imaging , Sclera/physiopathology , Adult , Case-Control Studies , Elasticity/physiology , Intraocular Pressure/physiology , Visual Acuity/physiology
6.
Turk Kardiyol Dern Ars ; 51(6): 369-377, 2023 09.
Article in English | MEDLINE | ID: mdl-37671520

ABSTRACT

OBJECTIVE: Impaired arterial elastic features is one of the earliest manifestations of atherosclerosis in the vessel wall and is associated with the development of cardiovascular disease and increased mortality and morbidity. In this study, we aimed to investigate the mean values of aortic elasticity parameters in a normotensive population with transthoracic echocardiography and to evaluate these values in different age groups and their relationship with other risk factors. METHODS: This retrospective study included 405 subjects who met the inclusion criteria among 2880 individuals screened between 2020 and 2022. The study population was divided into 5 groups according to their age. Aortic elasticity parameters (aortic strain, aortic stiffness index, and aortic distensibility) were calculated from the associated formulas by measurements made from the ascending aorta in the parasternal long axis. RESULTS: In 405 subjects (mean age 42.18 ± 10.39, 54.3% female), the mean aortic strain value was 15.14 ± 3.56%, the mean aortic stiffness index was 3.24 ± 1.05, and the mean aortic distensibility was 7.48 ± 2.36 cm2/dyn1/103. It was observed that aortic strain and distensibility values significantly decreased with increasing age groups, while aortic stiffness significantly increased. All 3 aortic elasticity parameters were strongly correlated to age. In the multivariate linear regression analysis, age was found to be an independent factor for all aortic elasticity parameters. CONCLUSION: Aortic elasticity parameters can be evaluated with transthoracic echocardiography in daily practice. Comparing these measurements with normal values in similar age groups may help to detect patients with increased cardiovascular risk in the early period, regardless of the other risk factors.


Subject(s)
Aorta , Elasticity , Female , Humans , Male , Aorta/diagnostic imaging , Aorta/physiology , Atherosclerosis/diagnostic imaging , Echocardiography , Elasticity/physiology , Retrospective Studies , Adult , Middle Aged , Age Factors , Heart Disease Risk Factors , Reference Values
7.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 40(1): 87-94, 2023 Feb 25.
Article in Chinese | MEDLINE | ID: mdl-36854552

ABSTRACT

Extracellular matrix (ECM) has been implicated in tumor progress and chemosensitivity. Ovarian cancer brings a great threat to the health of women with a significant feature of high mortality and poor prognosis. However, the potential significance of matrix stiffness in the pattern of long non-coding RNAs (lncRNAs) expression and ovarian cancer drug sensitivity is still largely unkown. Here, based on RNA-seq data of ovarian cancer cell cultured on substrates with different stiffness, we found that a great amount of lncRNAs were upregulated in stiff group, whereas SNHG8 was significantly downregulated, which was further verified in ovarian cancer cells cultured on polydimethylsiloxane (PDMS) hydrogel. Knockdown of SNHG8 led to an impaired efficiency of homologous repair, and decreased cellular sensitivity to both etoposide and cisplatin. Meanwhile, the results of the GEPIA analysis indicated that the expression of SNHG8 was significantly decreased in ovarian cancer tissues, which was negatively correlated with the overall survival of patients with ovarian cancer. In conclusion, matrix stiffening related lncRNA SNHG8 is closely related to chemosensitivity and prognosis of ovarian cancer, which might be a novel molecular marker for chemotherapy drug instruction and prognosis prediction.


Subject(s)
Elasticity , Extracellular Matrix , Ovarian Neoplasms , RNA, Long Noncoding , Female , Humans , Cisplatin/pharmacology , Elasticity/physiology , Etoposide , Extracellular Matrix/genetics , Extracellular Matrix/physiology , Ovarian Neoplasms/genetics , Ovarian Neoplasms/metabolism , RNA, Long Noncoding/genetics , RNA, Long Noncoding/metabolism
8.
Biomaterials ; 292: 121928, 2023 01.
Article in English | MEDLINE | ID: mdl-36455488

ABSTRACT

Regulatory T cells (Tregs) provide an essential tolerance mechanism to suppress the immune response. Induced Tregs hold the potential to treat autoimmune diseases in adoptive therapy and can be produced with stimulating signals to CD3 and CD28 in presence of the cytokine TGF-ß and IL-2. This report examines the modulation of human Treg induction by leveraging the ability of T cells to sense the mechanical stiffness of an activating substrate. Treg induction on polyacrylamide gels (PA-gels) was sensitive to the substrate's elastic modulus, increasing with greater material stiffness. Single-cell RNA-Seq analysis revealed that Treg induction on stiffer substrates involved greater use of oxidative phosphorylation (OXPHOS). Inhibition of ATP synthase significantly reduced the rate of Treg induction and abrogated the difference among gels while activation of AMPK (AMP-activated protein kinase) increased Treg induction on the softer sample but not on the harder sample. Treg induction is thus mechanosensitive and OXPHOS-dependent, providing new strategies for improving the production of these cells for cellular immunotherapy.


Subject(s)
Elasticity , Immune Tolerance , T-Lymphocytes, Regulatory , Humans , CD28 Antigens , Cytokines/metabolism , T-Lymphocytes, Regulatory/metabolism , Transforming Growth Factor beta/metabolism , Mechanical Phenomena , Elasticity/physiology
9.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-970677

ABSTRACT

Extracellular matrix (ECM) has been implicated in tumor progress and chemosensitivity. Ovarian cancer brings a great threat to the health of women with a significant feature of high mortality and poor prognosis. However, the potential significance of matrix stiffness in the pattern of long non-coding RNAs (lncRNAs) expression and ovarian cancer drug sensitivity is still largely unkown. Here, based on RNA-seq data of ovarian cancer cell cultured on substrates with different stiffness, we found that a great amount of lncRNAs were upregulated in stiff group, whereas SNHG8 was significantly downregulated, which was further verified in ovarian cancer cells cultured on polydimethylsiloxane (PDMS) hydrogel. Knockdown of SNHG8 led to an impaired efficiency of homologous repair, and decreased cellular sensitivity to both etoposide and cisplatin. Meanwhile, the results of the GEPIA analysis indicated that the expression of SNHG8 was significantly decreased in ovarian cancer tissues, which was negatively correlated with the overall survival of patients with ovarian cancer. In conclusion, matrix stiffening related lncRNA SNHG8 is closely related to chemosensitivity and prognosis of ovarian cancer, which might be a novel molecular marker for chemotherapy drug instruction and prognosis prediction.


Subject(s)
Female , Humans , Cisplatin/pharmacology , Elasticity/physiology , Etoposide , Extracellular Matrix/physiology , Ovarian Neoplasms/metabolism , RNA, Long Noncoding/metabolism
10.
Cornea ; 41(4): 478-483, 2022 Apr 01.
Article in English | MEDLINE | ID: mdl-35244628

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the effect of Descemet membrane endothelial keratoplasty (DMEK) graft storage time on its elastic properties, measured using atomic force microscopy (AFM). METHODS: Twenty human corneas (from 10 donors), unsuitable for transplantation, were obtained from the eye bank (S. Fyodorov Eye Microsurgery State Institution, Moscow). Ten DMEK grafts were prepared and stored in the corneal storage medium, Optisol-GS at 4°C after preparation, and AFM analysis was performed within 12 hours after preparation (group A). Ten paired corneas from the respective donors were stored in Optisol-GS at 4°C for 1 week after preparation before AFM analysis (group B). Data were analyzed using the Hertz model for the evaluation of the Young modulus of elasticity. RESULTS: Force-distance curve analysis showed an increase in the Young modulus of elasticity in group B in comparison with that in group A, and the mean values were 10.4 ± 1.8 kPa and 6.77 ± 2.25 kPa, respectively (P < 0.001). There was no correlation between the Young modulus of elasticity and donor age (r = 0.110, P = 0.644), endothelial cell count (r = -0.145, P = 0.541), and procurement interval (r = 0.14, P = 0.755). CONCLUSIONS: A longer graft storage time in cold storage medium was found to significantly reduce the elasticity of the DMEK graft. Clinically, this could potentially influence the unfolding of the DMEK graft within the anterior chamber during surgery and the postoperative detachment rate.


Subject(s)
Descemet Membrane/physiology , Descemet Stripping Endothelial Keratoplasty , Elasticity/physiology , Endothelium, Corneal/cytology , Graft Survival/physiology , Organ Preservation/methods , Aged , Chondroitin Sulfates/pharmacology , Complex Mixtures/pharmacology , Descemet Membrane/diagnostic imaging , Dextrans/pharmacology , Female , Gentamicins/pharmacology , Humans , Male , Microscopy, Atomic Force , Middle Aged , Organ Culture Techniques , Time Factors , Tissue and Organ Harvesting
11.
Invest Ophthalmol Vis Sci ; 63(2): 20, 2022 02 01.
Article in English | MEDLINE | ID: mdl-35142787

ABSTRACT

Purpose: It is unclear how the iris deforms during changes in pupil size. Here, we report an application of a multi-feature iris tracking method, which we call irissometry, to investigate how the iris deforms and affects the eye position signal as a function of pupil size. Methods: To evoke pupillary responses, we repeatedly presented visual and auditory stimuli to healthy participants while we additionally recorded their right eye with a macro lens-equipped camera. We tracked changes in iris surface structure between the pupil and sclera border (limbus) by calculating local densities (distance between feature points) across evenly spaced annular iris regions. Results: The time analysis of densities showed that the inner regions of the iris stretched more strongly as compared with the outer regions of the iris during pupil constrictions. The pattern of iris densities across eccentricities and pupil size showed highly similar patterns across participants, highlighting the robustness of this elastic property. Importantly, iris-based eye position detection led to more stable signals than pupil-based detection. Conclusions: The iris regions near the pupil appear to be more elastic than the outer regions near the sclera. This elastic property explains the instability of the pupil border and the related position errors induced by eye movement and pupil size in pupil-based eye-tracking. Tracking features in the iris produce more robust eye position signals. We expect that irissometry may pave the way to novel eye trackers and diagnostic tools in ophthalmology.


Subject(s)
Elasticity/physiology , Eye-Tracking Technology , Iris/physiology , Pupil/physiology , Video Recording , Adolescent , Adult , Elasticity Imaging Techniques , Eye Movements/physiology , Female , Healthy Volunteers , Humans , Male , Young Adult
12.
Proc Natl Acad Sci U S A ; 119(8)2022 02 22.
Article in English | MEDLINE | ID: mdl-35169074

ABSTRACT

Cells are filled with macromolecules and polymer networks that set scale-dependent viscous and elastic properties to the cytoplasm. Although the role of these parameters in molecular diffusion, reaction kinetics, and cellular biochemistry is being increasingly recognized, their contributions to the motion and positioning of larger organelles, such as mitotic spindles for cell division, remain unknown. Here, using magnetic tweezers to displace and rotate mitotic spindles in living embryos, we uncovered that the cytoplasm can impart viscoelastic reactive forces that move spindles, or passive objects with similar size, back to their original positions. These forces are independent of cytoskeletal force generators yet reach hundreds of piconewtons and scale with cytoplasm crowding. Spindle motion shears and fluidizes the cytoplasm, dissipating elastic energy and limiting spindle recoils with functional implications for asymmetric and oriented divisions. These findings suggest that bulk cytoplasm material properties may constitute important control elements for the regulation of division positioning and cellular organization.


Subject(s)
Cytoplasm/physiology , Elasticity/physiology , Spindle Apparatus/physiology , Animals , Biomechanical Phenomena/physiology , Cell Division/physiology , Diffusion , Kinetics , Magnetic Phenomena , Microtubules , Mitosis/physiology , Organelles , Sea Urchins , Viscosity
13.
Int J Mol Sci ; 23(4)2022 Feb 14.
Article in English | MEDLINE | ID: mdl-35216218

ABSTRACT

Many extensible tissues such as skin, lungs, and blood vessels require elasticity to function properly. The recoil of elastic energy stored during a stretching phase is provided by elastic fibers, which are mostly composed of elastin and fibrillin-rich microfibrils. In arteries, the lack of elastic fibers leads to a weakening of the vessel wall with an increased risk to develop cardiovascular defects such as stenosis, aneurysms, and dissections. The development of new therapeutic molecules involves preliminary tests in animal models that recapitulate the disease and whose response to drugs should be as close as possible to that of humans. Due to its superior in vivo imaging possibilities and the broad tool kit for forward and reverse genetics, the zebrafish has become an important model organism to study human pathologies. Moreover, it is particularly adapted to large scale studies, making it an attractive model in particular for the first steps of investigations. In this review, we discuss the relevance of the zebrafish model for the study of elastic fiber-related vascular pathologies. We evidence zebrafish as a compelling alternative to conventional mouse models.


Subject(s)
Blood Vessels/metabolism , Blood Vessels/pathology , Elastic Tissue/metabolism , Elastic Tissue/pathology , Fibrillins/metabolism , Zebrafish/metabolism , Zebrafish/physiology , Animals , Elasticity/physiology , Humans , Microfilament Proteins/metabolism
14.
Int J Mol Sci ; 23(4)2022 Feb 15.
Article in English | MEDLINE | ID: mdl-35216278

ABSTRACT

BACKGROUND: The aim of the research presented here was to find a set of parameters enabling discrimination between three types of fibroblasts, i.e., healthy ones and those derived from two disorders mimicking each other: idiopathic pulmonary fibrosis (IPF), and nonspecific interstitial pneumonia (NSIP). METHODS: The morphology and growth of cells were traced using fluorescence microscopy and analyzed quantitatively using cell proliferation and substrate cytotoxicity indices. The viability of cells was recorded using MTS assays, and their stiffness was examined using atomic force microscopy (AFM) working in force spectroscopy (FS) mode. To enhance any possible difference in the examined parameters, experiments were performed with cells cultured on substrates of different elasticities. Moreover, the chemical composition of cells was determined using time-of-flight secondary ion mass spectrometry (ToF-SIMS), combined with sophisticated analytical tools, i.e., Multivariate Curve Resolution (MCR) and Principal Component Analysis (PCA). RESULTS: The obtained results demonstrate that discrimination between cell lines derived from healthy and diseased patients is possible based on the analysis of the growth of cells, as well as their physical and chemical properties. In turn, the comparative analysis of the cellular response to altered stiffness of the substrates enables the identification of each cell line, including distinguishing between IPF- and NSIP-derived fibroblasts.


Subject(s)
Cell Proliferation/physiology , Fibroblasts/pathology , Idiopathic Interstitial Pneumonias/pathology , Idiopathic Pulmonary Fibrosis/pathology , Aged , Cell Line , Elasticity/physiology , Female , Humans , Lung/pathology
15.
Commun Biol ; 5(1): 17, 2022 01 11.
Article in English | MEDLINE | ID: mdl-35017622

ABSTRACT

Countless biophysical studies have sought distinct markers in the cellular mechanical response that could be linked to morphogenesis, homeostasis, and disease. Here, an iterative-fitting methodology visualizes the time-dependent viscoelastic behavior of human skin cells under physiologically relevant conditions. Past investigations often involved parameterizing elastic relationships and assuming purely Hertzian contact mechanics, which fails to properly account for the rich temporal information available. We demonstrate the performance superiority of the proposed iterative viscoelastic characterization method over standard open-search approaches. Our viscoelastic measurements revealed that 2D adherent metastatic melanoma cells exhibit reduced elasticity compared to their normal counterparts-melanocytes and fibroblasts, and are significantly less viscous than fibroblasts over timescales spanning three orders of magnitude. The measured loss angle indicates clear differential viscoelastic responses across multiple timescales between the measured cells. This method provides insight into the complex viscoelastic behavior of metastatic melanoma cells relevant to better understanding cancer metastasis and aggression.


Subject(s)
Elasticity/physiology , Fibroblasts/physiology , Melanocytes/physiology , Skin/cytology , Cell Line, Tumor , Cells, Cultured , Fibroblasts/cytology , Humans , Melanocytes/cytology , Melanoma/physiopathology , Skin Neoplasms/physiopathology , Viscosity
16.
Plant Physiol ; 188(3): 1435-1449, 2022 03 04.
Article in English | MEDLINE | ID: mdl-34908122

ABSTRACT

Mechanical properties, size and geometry of cells, and internal turgor pressure greatly influence cell morphogenesis. Computational models of cell growth require values for wall elastic modulus and turgor pressure, but very few experiments have been designed to validate the results using measurements that deform the entire thickness of the cell wall. New wall material is synthesized at the inner surface of the cell such that full-thickness deformations are needed to quantify relevant changes associated with cell development. Here, we present an integrated, experimental-computational approach to analyze quantitatively the variation of elastic bending behavior in the primary cell wall of living Arabidopsis (Arabidopsis thaliana) pavement cells and to measure turgor pressure within cells under different osmotic conditions. This approach used laser scanning confocal microscopy to measure the 3D geometry of single pavement cells and indentation experiments to probe the local mechanical responses across the periclinal wall. The experimental results were matched iteratively using a finite element model of the experiment to determine the local mechanical properties and turgor pressure. The resulting modulus distribution along the periclinal wall was nonuniform across the leaf cells studied. These results were consistent with the characteristics of plant cell walls which have a heterogeneous organization. The results and model allowed the magnitude and orientation of cell wall stress to be predicted quantitatively. The methods also serve as a reference for future work to analyze the morphogenetic behaviors of plant cells in terms of the heterogeneity and anisotropy of cell walls.


Subject(s)
Arabidopsis/growth & development , Cell Wall/physiology , Elasticity/physiology , Plant Development/physiology , Plant Leaves/growth & development , Stress, Mechanical
17.
Rev. bras. oftalmol ; 81: e0036, 2022. tab, graf
Article in English | LILACS | ID: biblio-1376779

ABSTRACT

ABSTRACT The purpose of this study was to highlight the impact of biomechanical corneal response in available in vivo tonometry methods for glaucoma management. Systematic review of non-contact air-puff tonometers that analyzes the corneal deformation response, with special focus on the investigation of the correlation of derived parameters with intraocular pressure measurements. The two actual and commercially available in vivo corneal tonometers provide promising information about biomechanical characteristics of the cornea and its relation to glaucoma, allowing the development of new protocols to evaluate, diagnose, and manage this disease.


RESUMO O objetivo deste estudo é destacar o impacto da resposta biomecânica corneana em métodos de tonometria in vivo disponíveis para o manejo do glaucoma. Trata-se de revisão sistemática de tonômetros de ar que analisa a resposta à deformação corneana, com foco especial na investigação da correlação dos parâmetros derivados com as medições da pressão intraocular. Os dois tonômetros mais recentes e comercialmente disponíveis fornecem informações promissoras sobre as características biomecânicas da córnea e sua relação com o glaucoma, permitindo o desenvolvimento de novos protocolos para avaliar, diagnosticar e controlar a doença.


Subject(s)
Humans , Tonometry, Ocular/instrumentation , Tonometry, Ocular/methods , Biomechanical Phenomena , Cornea/anatomy & histology , Cornea/physiology , Intraocular Pressure/physiology , Glaucoma/physiopathology , Ocular Hypertension/physiopathology , Diagnostic Techniques, Ophthalmological/instrumentation , Elasticity/physiology , Models, Theoretical
18.
Invest Ophthalmol Vis Sci ; 62(15): 3, 2021 12 01.
Article in English | MEDLINE | ID: mdl-34854885

ABSTRACT

Purpose: Fine focusing of light by the eye lens onto the retina relies on the ability of the lens to change shape during the process of accommodation. Little is known about the cellular structures that regulate elasticity and resilience. We tested whether Eph-ephrin signaling is involved in lens biomechanical properties. Methods: We used confocal microscopy and tissue mechanical testing to examine mouse lenses with genetic disruption of EphA2 or ephrin-A5. Results: Confocal imaging revealed misalignment of the suture between each shell of newly added fiber cells in knockout lenses. Despite having disordered sutures, loss of EphA2 or ephrin-A5 did not affect lens stiffness. Surprisingly, knockout lenses were more resilient and recovered almost completely after load removal. Confocal microscopy and quantitative image analysis from live lenses before, during, and after compression revealed that knockout lenses had misaligned Y-sutures, leading to a change in force distribution during compression. Knockout lenses displayed decreased separation of fiber cell tips at the anterior suture at high loads and had more complete recovery after load removal, which leads to improved whole-lens resiliency. Conclusions: EphA2 and ephrin-A5 are needed for normal patterning of fiber cell tips and the formation of a well-aligned Y-suture with fiber tips stacked on top of previous generations of fiber cells. The misalignment of lens sutures leads to increased resilience after compression. The data suggest that alignment of the Y-suture may constrain the overall elasticity and resilience of the lens.


Subject(s)
Elasticity/physiology , Lens, Crystalline/physiology , Receptor, EphA2/physiology , Receptor, EphA5/physiology , Animals , Biomechanical Phenomena , Cell Shape , Mice , Mice, Inbred C57BL , Mice, Knockout , Microscopy, Confocal , Protein Transport , Signal Transduction/physiology
19.
Sci Rep ; 11(1): 23566, 2021 12 07.
Article in English | MEDLINE | ID: mdl-34876652

ABSTRACT

The viscoelastic properties of red blood cells (RBC) facilitate flexible shape change in response to extrinsic forces. Their viscoelasticity is intrinsically linked to physical properties of the cytosol, cytoskeleton, and membrane-all of which are highly sensitive to supraphysiological shear exposure. Given the need to minimise blood trauma within artificial organs, we observed RBC in supraphysiological shear through direct visualisation to gain understanding of processes leading to blood damage. Using a custom-built counter-rotating shear generator fit to a microscope, healthy red blood cells (RBC) were directly visualised during exposure to different levels of shear (10-60 Pa). To investigate RBC morphology in shear flow, we developed an image analysis method to quantify (a)symmetry of deforming ellipsoidal cells-following RBC identification and centroid detection, cell radius was determined for each angle around the circumference of the cell, and the resultant bimodal distribution (and thus RBC) was symmetrically compared. While traditional indices of RBC deformability (elongation index) remained unaltered in all shear conditions, following ~100 s of exposure to 60 Pa, the frequency of asymmetrical ellipses and RBC fragments/extracellular vesicles significantly increased. These findings indicate RBC structure is sensitive to shear history, where asymmetrical morphology may indicate sublethal blood damage in real-time shear flow.


Subject(s)
Erythrocyte Deformability/physiology , Erythrocytes/physiology , Erythrocytes/ultrastructure , Adult , Blood Viscosity/physiology , Elasticity/physiology , Hemolysis/physiology , Humans , In Vitro Techniques , Male , Stress, Mechanical , Young Adult
20.
BMC Urol ; 21(1): 163, 2021 Nov 27.
Article in English | MEDLINE | ID: mdl-34837995

ABSTRACT

BACKGROUND: Hypospadias is a relatively common genital anomaly in humans, usually followed by inelastic dartos that causes penile chordee. Vascular endothelial growth factor (VEGF) is strongly linked to the viscoelasticity of tissues and their elastic phase. This study aimed to evaluate VEGF expressions in (1) fascia dartos between hypospadias and controls and (2) chordee severity. METHODS: This prospective cohort study involved 65 specimens from patients with hypospadias and ten specimens from controls. The samples were analyzed by quantitative real-time polymerase chain reaction (qPCR) for VEGF expression. RESULTS: The expressions of VEGF were not different between proximal and distal hypospadias patients and controls (fold change: distal - 0.25; fold change: proximal - 0.2; p = 0.664). The scaled expressions related to chordee severity were mild - 0.1; moderate 0.1; severe - 0.25 (p = 0.660). CONCLUSIONS: VEGF expressions might not affect the severity of hypospadias and chordee, implying the pathogenesis is complex involving many growth factors. Further study with a larger sample size is necessary to clarify and confirm our findings.


Subject(s)
Elasticity/physiology , Hypospadias/metabolism , Penis/physiopathology , RNA, Messenger/metabolism , Vascular Endothelial Growth Factors/metabolism , Case-Control Studies , Child , Child, Preschool , Humans , Hypospadias/physiopathology , Male , Penis/abnormalities , Penis/physiology , Vascular Endothelial Growth Factors/genetics