Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters











Publication year range
1.
Rev Gastroenterol Mex (Engl Ed) ; 89(3): 332-339, 2024.
Article in English | MEDLINE | ID: mdl-38644085

ABSTRACT

INTRODUCTION AND AIMS: Adequate drying and proper storage of flexible endoscopes are essential for maintaining quality in their reprocessing. The aim of the present study was to evaluate the drying stages, storage, and channel conditions of endoscopes through borescope inspection. MATERIAL AND METHODS: The personnel responsible for endoscope reprocessing were interviewed. Storage conditions at 10 endoscopy facilities were inspected and an internal examination of the channels and ports of the stored equipment was carried out, utilizing a borescope. A total of 74 stored endoscope channels were evaluated. RESULTS: Only 10% of the facilities inspected utilized transport cases for storage and only 10% had rooms exclusively used for storage. Sixty percent of the facilities did not perform any shelf-life control. All the channels evaluated were scratched and fluids were present on 69% of them. CONCLUSIONS: Endoscope reprocessing can be improved through the implementation of drying and storage control and validation tools, as well as the use of borescopes and periodic clinical audits.


Subject(s)
Endoscopes , Equipment Reuse , Humans , Endoscopes/standards , Equipment Reuse/standards , Equipment Contamination/prevention & control , Disinfection/methods , Disinfection/standards , Desiccation
2.
Córdoba; s.n; 2006. 78 p. ilus, 28 cm +, disquette con resumen de tesis.
Thesis in Spanish | LILACS | ID: lil-479565

ABSTRACT

Se presenta una técnica, hoy de uso frecuente; la gastrostomía endoscópica percutánea (GEP) aplicada en pacientes con dificultad en la deglución o disminución del reflejo deglutorio. En la introducción se define la problemática de esta patología, una reseña histórica y secuencia de desarrollo de la aparatología utilizada. Como objetivo buscamos presentar una técnica, valorarla, comparar indicaciones, contraindicaciones, resultados y morbilidad del procedimiento clásico.Se destaca en el cuerpo del trabajo dicha técnica, como metodología válida para la solución del aporte nutricional, mostrando datos de seguimiento a través de gráficas de crecimiento (peso/edad) con control prequirúrgico y de hasta 18 meses. En la casuística fue estricta la colección de datos para que los resultados sean objetivables y reproducibles. Las variables estudiadas comprenden: edad, sexo, año del procedimiento, lugar del procedimiento, diagnóstico al ingreso, tipo de técnica, material descartable utilizado, diámetro de las sondas, alimentación pre-tratamiento, vía de alimentación, hallazgos radiológicos, peso pre-tratamiento y post-seguimiento. Los resultados obtenidos definen y muestran una tendencia de comportamiento de los pacientes a través del tiempo de aumento de peso


Subject(s)
Humans , Male , Female , Child , Endoscopy , Endoscopes/standards , Endoscopes , Gastrostomy/methods , Deglutition Disorders/complications
4.
São Paulo; Secretaria da Saúde. Coordenação de Vigilância em Saúde; set. 2005. 2 p.
Non-conventional in Portuguese | LILACS, Coleciona SUS, COVISA-Producao, Sec. Munic. Saúde SP, Sec. Munic. Saúde SP | ID: biblio-937398
6.
GED gastroenterol. endosc. dig ; GED gastroenterol. endosc. dig;16(2): 41-6, mar.-abr. 1997. tab
Article in Portuguese | LILACS | ID: lil-212919

ABSTRACT

Embora seja descrita comm pouca freqüência, a transmissäo de infecçao por endoscopia é preocupaçäo crescente. Muitos säo os fatores que podem dificultar a realizaçäo da desinfecçäo de alto nível, que é preconizada para os endoscópicos: configuraçäo do equipamento, necessidade de pessoal especializado e relaçäo entre o número de endoscópios disponíveis e o número de exames realizados no serviço. Baseados em estudos recentes, elaboramos um questionário que foi encaminhado a 83 hospitais da cidade de säo Paulo, com o intuito de avaliar como é feito o reprocessamento desse material. Para nossa surpresa, em apenas um hospital as recomendaçöes da literatura médica säo seguidas, embora a maioria deles apresentasse infra-estrutura que permitiria a realizaçäo da desinfecçäo de alto nível. As falhas estiveram presentes em todas as etapas: limpeza, desinfecçäo, enxágüe e estocagem. Podemos concluir que divulgaçäo das medidas a serem seguidas e educaçäo continuada dos profissionais responsáveis por esses serviços säo fundamentais para que possamos atingir padröes internacionais no que diz respeito à desinfecçäo do equipamento utilizado em endoscopia digestiva.


Subject(s)
Humans , Disinfection , Endoscopes/standards , Endoscopy/standards , Endoscopes/microbiology , Infection Control
SELECTION OF CITATIONS
SEARCH DETAIL