Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 202
Filter
1.
N Z Med J ; 137(1600): 62-65, 2024 Aug 02.
Article in English | MEDLINE | ID: mdl-39088810

ABSTRACT

AIM: The aim of this study was to follow the instruments' pathways and cost each segment to calculate whether reusable or disposable ophthalmic instruments offer better value for money for intravitreal injections. METHODS: The cycles and costs of reusable and single-use disposable instruments used for intravitreal injections were mapped out, including purchase costs, transport to and from the place of use, opening and disposal, sterilisation, replacement, salary costs of staff involved, etc. results: The cost of using reusable instruments for intravitreal injections (NZ$29.00) was lower than the cost of using disposable instruments ($30.51) by $1.51 per patient. CONCLUSIONS: Intravitreal injections performed with reusable instruments offer better value for money than when performed with disposable instruments. This equates to a beneficial financial saving just for this one low-complexity case. Such savings can multiply significantly when considering the instruments used in a wider variety of ophthalmic procedures. There are of course trade-offs between safety, quality, cost and sustainability.


Subject(s)
Disposable Equipment , Equipment Reuse , Intravitreal Injections , Intravitreal Injections/instrumentation , Intravitreal Injections/economics , Disposable Equipment/economics , Humans , Equipment Reuse/economics , New Zealand , Cost-Benefit Analysis
2.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 55(3): 762-768, 2024 May 20.
Article in Chinese | MEDLINE | ID: mdl-38948302

ABSTRACT

Objective: Ultrasound diagnosis and treatment is easy to perform and takes little time. It is widely used in clinical practice thanks to its non-invasive, real-time, and dynamic characteristics. In the process of ultrasound diagnosis and treatment, the probe may come into contact with the skin, the mucous membranes, and even the sterile parts of the body. However, it is difficult to achieve effective real-time disinfection of the probes after use and the probes are often reused, leading to the possibility of the probes carrying multiple pathogenic bacteria. At present, the processing methods for probes at home and abroad mainly include probe cleaning, probe disinfection, and physical isolation (using probe covers or sheaths). Yet, each approach has its limitations and cannot completely prevent probe contamination and infections caused by ultrasound diagnosis and treatment. For example, when condoms are used as the probe sheath, the rate of condom breakage is relatively high. The cutting and fixing of cling film or freezer bags involves complicated procedures and is difficult to perform. Disposable plastic gloves are prone to falling off and causing contamination and are hence not in compliance with the principles of sterility. Furthermore, the imaging effect of disposable plastic gloves is poor. Therefore, there is an urgent need to explore new materials to make probe covers that can not only wrap tightly around the ultrasound probe, but also help achieve effective protection and rapid reuse. Based on the concept of physical barriers, we developed in this study a heat sealing system for the rapid reuse of ultrasound probes. The system uses a heat sealing device to shrink the protective film so that it wraps tightly against the surface of the ultrasound probe, allowing for the rapid reuse of the probe while reducing the risk of nosocomial infections. The purpose of this study is to design a heat sealing system for the rapid reuse of ultrasound probes and to verify its application effect on the rapid reuse of ultrasound probes. Methods: 1) The heat sealing system for the rapid reuse of ultrasound probes was designed and tested by integrating medical and engineering methods. The system included a protective film (a multilayer co-extruded polyolefin thermal shrinkable film) and a heat sealing device, which included heating wire components, a blower, a photoelectric switch, temperature sensors, a control and drive circuit board, etc. According to the principle of thermal shrinkage, the ultrasound probe equipped with thermal shrinkable film was rapidly heated and the film would wrap closely around the ultrasound probe placed on the top of the heat sealing machine. The ultrasound probe was ready for use after the thermal shrinkage process finished. Temperature sensors were installed on the surface of the probe to test the thermal insulation performance of the system. The operation procedures of the system are as follows: placing the ultrasound probe covered with the protective film in a certain space above the protective air vent, which is detected by the photoelectric switch; the heating device heats the thermal shrinkable film with a constant flow of hot air at a set temperature value. Then, the probe is rotated so that the thermal shrinkable film will quickly wrap around the ultrasound probe. After the heat shrinking is completed, the probe can be used directly. 2) Using the convenience sampling method, 90 patients from the Department of Anesthesiology and Perioperative Medicine, the First Affiliated Hospital of Xi'an Jiaotong University were included as the research subjects. All patients were going to undergo arterial puncture under ultrasound guidance. The subjects were divided into 3 groups, with 30 patients in each group. Three measures commonly applied in clinical practice were used to process the probes in the three groups and water-soluble fluorescent labeling was applied around the puncture site before use. In the experimental group, the probes were processed with the heat sealing system. The standard operating procedures of the heat sealing system for rapid reuse of ultrasonic probes were performed to cover the ultrasonic probe and form a physical barrier to prevent probe contamination. There were two control groups. In control group 1, disinfection wipes containing double-chain quaternary ammonium salt were used to repeatedly wipe the surface of the probe for 10-15 times, and then the probe was ready for use once it dried up. In the control group 2, a disposable protective sheath was used to cover the front end of the probe and the handle end of the sheath was tied up with threads. Comparison of the water-soluble fluorescent labeling on the surface of the probe (which reflected the colony residues on the surface of the probe) before and after use and the reuse time (i.e., the lapse of time from the end of the first use to the beginning of the second use) were made between the experimental group and the two control groups. Results: 1) The temperature inside the ultrasound probe was below 40 ℃ and the heat sealing system for rapid reuse did not affect the performance of the ultrasound probe. 2) The reuse time in the heat sealing system group, as represented by (median [P25, P75]), was (8.00 [7.00, 10.00]) s, which was significantly lower than those of the disinfection wipe group at (95.50 [8.00, 214.00]) s and the protective sleeve group at (25.00 [8.00, 51.00]) s, with the differences being statistically significant (P<0.05). No fluorescence residue was found on the probe in either the heat sealing system group or the protective sheath group after use. The fluorescence residue in the heat sealing system group was significantly lower than that in the disinfection wipes group, showing statistically significant differences (χ 2=45.882, P<0.05). Conclusion: The thermal shrinkable film designed and developed in this study can be cut and trimmed according to the size of the equipment. When the film is heated, it shrinks and wraps tightly around the equipment, forming a sturdy protective layer. With the heat sealing system for rapid reuse of ultrasonic probes, we have realized the semi-automatic connection between the thermal shrinkable film and the heating device, reducing the amount of time-consuming and complicated manual operation. Furthermore, the average reuse time is shortened and the system is easy to use, which contributes to improvements in the reuse and operation efficiency of ultrasound probes. The heat sealing system reduces colony residues on the surface of the probe and forms an effective physical barrier on the probe. No probes were damaged in the study. The heat sealing system for rapid reuse of ultrasonic probes can be used as a new method to process the ultrasonic probes.


Subject(s)
Ultrasonography , Ultrasonography/instrumentation , Ultrasonography/methods , Hot Temperature , Equipment Reuse , Humans , Disinfection/methods , Disinfection/instrumentation , Equipment Design , Equipment Contamination/prevention & control
3.
BMC Urol ; 24(1): 149, 2024 Jul 18.
Article in English | MEDLINE | ID: mdl-39026274

ABSTRACT

OBJECTIVES: To compare the clinical efficacy and safety of single-use and reusable digital flexible ureteroscopy for the treatment of lower pole stones. METHODS: We enrolled 135 patients underwent reusable flexible ureteroscopy (FURS) and 78 patients underwent single-use digital FURS. Demographic, clinical variables, anatomical parameters of the lower calyx and perioperative indicators were compared in the two groups. RESULTS: Thirty-six patients in the infundibuloureter angle (IPA) < 45° subgroup had a mini-percutaneous nephrolithotomy (mini-PCNL), including 25 patients in the reusable FURS group and 11 patients in the single-use FURS group. The demographic and clinical variables in the two FURS groups were comparable. There was no statistical difference in the success rate of stone searching (P > 0.05). In terms of the success rate of lithotripsy, there was also no statistical difference in the IPA ≥ 45° subgroup (P > 0.05), whereas single-use FURS was superior in the IPA < 45° subgroup (χ2 = 6.513, P = 0.011). The length of the working fiber in the reusable FURS and single-use FURS groups was 3.20 ± 0.68 mm and 1.75 ± 0.47 mm, respectively (t = 18.297, P < 0.05). The use of a stone basket in the reusable FURS (31/135, 23.0%) was significantly higher than that in the single-use FURS (8/78, 10.3%) (χ2 = 5.336, P = 0.021). Compared with the reusable FURS group, the single-use FURS group had shorter operation times (P < 0.05) and higher stone-free rate (SFR) (χ2 = 4.230, P = 0.040). There was no statistical difference in the intraoperative transfer of mini-PCNL and postoperative complications between the two groups (P > 0.05). CONCLUSIONS: Single-use and reusable FURS are alternative methods for removal of lower pole stones (i.e., 2 cm or less). Single-use FURS has a high success rate of lithotripsy, shorter operation time, and high stone-free rate.


Subject(s)
Equipment Reuse , Kidney Calculi , Ureteroscopes , Ureteroscopy , Humans , Ureteroscopy/methods , Ureteroscopy/instrumentation , Male , Female , Retrospective Studies , Kidney Calculi/surgery , Middle Aged , Adult , Case-Control Studies , Treatment Outcome , Equipment Design , Disposable Equipment , Aged
4.
Rev Lat Am Enfermagem ; 32: e4209, 2024.
Article in English, Spanish, Portuguese | MEDLINE | ID: mdl-38985043

ABSTRACT

OBJECTIVE: to analyze the integrity of N95/PFF2 masks in relation to fiber morphology, porosity, cracks and micro holes, as well as identify visible damage to their structure and components, after seven- and fifteen-day reuse protocols. METHOD: cross-sectional study. Structural and morphological characteristics of a new N95/PFF2 mask were analyzed in comparison with N95/PFF2 masks (n=10) used in seven- and fifteen-day protocols, through visual inspection and scanning electron microscopy. RESULTS: upon visual inspection, following the seven-day protocol, 40% and 60% of the N95/PFF2 masks showed, respectively, personal identification marks and external and internal dirt. Additionally, 20% exhibited loosening and/or tearing of the straps, while 100% showed some type of damage to the nose clips. In the fifteen-day protocol, all N95/PFF2 masks had dirt, loose straps and damaged nose clips, and 80% had folds. Electronic microscopy revealed an increase in pores and loosening in the weaves from seven days onwards, extending up to fifteen days, with the presence of micro holes and residues. CONCLUSION: the reuse of N95/PFF2 masks affects their structural and morphological integrity. It is crucial to carry out tests to measure the impact of this practice on the safety of health professionals.


Subject(s)
Equipment Reuse , Cross-Sectional Studies , Equipment Reuse/standards , Humans , N95 Respirators/standards , Microscopy, Electron, Scanning , Masks/standards
5.
J Surg Orthop Adv ; 33(2): 97-102, 2024.
Article in English | MEDLINE | ID: mdl-38995066

ABSTRACT

The association between the reuse of surgical masks (SMs) for multiple procedures and rates of surgical site infections (SSIs) is unclear. Hence, the purpose of this study was to determine whether a policy mandating the reuse of SMs was associated with increased SSI incidence. It was hypothesized the rate of SSIs would be significantly greater during the postimplementation period compared with the preimplementation period. Retrospective chart review of patients who underwent orthopaedic and general surgery during the 60 days before and after policy implementation was performed. Focus was on consecutive procedures performed by the same surgeon on the same day. An assessment of SSI risk factors suggested the postimplementation group was at higher risk. However, the daily use of a single SM across multiple procedures was not associated with a clinically significant increase in SSIs. Because future pandemics and public health crises may be accompanied by similar shortages, it may be possible to reuse masks in these situations without concern for increased SSI. (Journal of Surgical Orthopaedic Advances 33(2):097-102, 2024).


Subject(s)
COVID-19 , Equipment Reuse , Masks , Surgical Wound Infection , Humans , COVID-19/epidemiology , COVID-19/prevention & control , Surgical Wound Infection/epidemiology , Surgical Wound Infection/prevention & control , Retrospective Studies , Incidence , Male , Female , Middle Aged , Aged , SARS-CoV-2 , Risk Factors , Orthopedic Procedures , Adult , Pandemics
8.
J Am Acad Orthop Surg ; 32(15): 705-711, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38861714

ABSTRACT

INTRODUCTION: Orthopaedic surgery is culpable, in part, for the excessive carbon emissions in health care partly due to the utilization of disposable instrumentation in most procedures, such as rotator cuff repair (RCR). To address growing concerns about hospital waste, some have considered replacing disposable instrumentation with reusable instrumentation. The purpose of this study was to estimate the cost and carbon footprint of waste disposal of RCR kits that use disposable instrumentation compared with reusable instrumentation. METHODS: The mass of the necessary materials and their packaging to complete a four-anchor RCR from four medical device companies that use disposable instrumentation and one that uses reusable instrumentation were recorded. Using the cost of medical waste disposal at our institution ($0.14 per kilogram) and reported values from the literature for carbon emissions produced from the low-temperature incineration of noninfectious waste (249 kgCO 2 e/t) and infectious waste (569 kgCO 2 e/t), we estimated the waste management cost and carbon footprint of waste disposal produced per RCR kit. RESULTS: The disposable systems of four commercial medical device companies had 783%, 570%, 1,051%, and 478%, respectively, greater mass and waste costs when compared with the reusable system. The cost of waste disposal for the reusable instrumentation system costs on average $0.14 less than the disposable instrumentation systems. The estimated contribution to the overall carbon footprint produced from the disposal of a RCR kit that uses reusable instrumentation was on average 0.37 kg CO2e less than the disposable instrumentation systems. CONCLUSION: According to our analysis, reusable instrumentation in four-anchor RCR leads to decreased waste and waste disposal costs and lower carbon emissions from waste disposal. Additional research should be done to assess the net benefit reusable systems may have on hospitals and the effect this may have on a long-term decrease in carbon footprint. LEVEL OF EVIDENCE: Level II.


Subject(s)
Carbon Footprint , Disposable Equipment , Equipment Reuse , Humans , Disposable Equipment/economics , Equipment Reuse/economics , Medical Waste Disposal , Rotator Cuff Injuries/surgery , Rotator Cuff Injuries/economics , Orthopedic Procedures/instrumentation , Orthopedic Procedures/economics , Suture Anchors , Medical Waste
9.
Surgeon ; 22(4): 236-241, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38862376

ABSTRACT

INTRODUCTION: As hospitals strive to reduce their environmental footprint, there is an ongoing debate over the environmental implications of reusable versus disposable linens in operating rooms (ORs). This research aimed to compare the environmental impact of reusable versus single-use OR bed covers and lift sheets using life cycle assessment (LCA) methodology. METHODS: LCA is an established tool with rigorous methodology that uses science-based processes to measure environmental impact. This study compared the impacts of three independent system scenarios at a single large academic hospital: reusable bed covers with 50 laundry cycles and subsequent landfill disposal (System 1), single-use bed covers with waste landfill disposal (System 2), and single-use bed covers with waste disposal using incineration (System 3). RESULTS: The total carbon footprint of System 1 for 50 uses was 19.83 â€‹kg carbon dioxide equivalents (CO2-eq). System 2 generated 64.99 â€‹kg CO2-eq. For System 3, the total carbon footprint was 108.98 â€‹kg CO2-eq. The raw material extraction for all the material to produce an equivalent 50 single-use OR bed cover kits was tenfold more carbon-intensive than the reusable bed cover. Laundering one reusable OR bed cover 50 times was more carbon intensive (12.12 â€‹kg CO2-eq) than landfill disposal of 50 single-use OR bed covers (2.52 â€‹kg CO2-eq). DISCUSSION: Our analysis demonstrates that one reusable fabric-based OR bed cover laundered 50 times, despite the carbon and water-intensive laundering process, exhibits a markedly lower carbon footprint than its single-use counterparts. The net difference is 45.16 â€‹kg CO2-eq, equivalent to driving 115 miles in an average gasoline-powered passenger vehicle. This stark contrast underscores the efficacy of adopting reusable solutions to mitigate environmental impact within healthcare facilities.


Subject(s)
Carbon Footprint , Equipment Reuse , Operating Rooms , Humans , Bedding and Linens , Disposable Equipment , Environment , Recycling
10.
Surg Laparosc Endosc Percutan Tech ; 34(3): 321-329, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38767593

ABSTRACT

OBJECTIVE: Endoscopes are an essential tool in the diagnosis, screening, and treatment of gastrointestinal diseases. In 2019, the Food and Drug Administration issued a news release, recommending that duodenoscope manufacturers and health care facilities phase out fully reusable duodenoscopes with fixed endcaps in lieu of duodenoscopes that are either fully disposable or those that contain disposable endcaps. With this study, we systematically reviewed the published literature on single-use disposable gastrointestinal scopes to describe the current state of the literature and provide summary recommendations on the role of disposable gastrointestinal endoscopes. MATERIALS AND METHODS: For our inclusion criteria, we searched for studies that were published in the year 2015 and afterward. We performed a literature search in PubMed using the keywords, "disposable," "reusable," "choledochoscope," "colonoscope," "duodenoscope," "esophagoscope," "gastroscope," and "sigmoidoscope." After our review, we identified our final article set, including 13 articles relating to disposable scopes, published from 2015 to 2023. RESULTS: In this review, we show 13 articles discussing the infection rate, functionality, safety, and affordability of disposable gastrointestinal scopes in comparison to reusable gastrointestinal scopes. Of the 3 articles that discussed infection rates (by Forbes and colleagues, Ridtitid and colleagues, and Ofosu and colleagues), each demonstrated a decreased risk of infection in disposable gastrointestinal scopes. Functionality was another common theme among these articles. Six articles (by Muthusamy and colleagues, Bang and colleagues, Lisotti and colleagues, Ross and colleagues, Kang and colleagues, and Forbes and colleagues) demonstrated comparable functionality of disposable scopes to reusable scopes. The most reported functionality issue in disposable scopes was decreased camera resolution. Disposable scopes also showed comparable safety profiles compared with reusable scopes. Six articles (by Kalipershad and colleagues, Muthusamy and colleagues, Bang and colleagues, Lisotti and colleagues, Luo and colleagues, and Huynh and colleagues) showed comparable rates of AEs, whereas 1 article (by Ofosu and colleagues) demonstrated increased rates of AEs with disposable scopes. Lastly, a cost analysis was looked at in 3 of the articles. Two articles (by Larsen et al and Ross and colleagues) remarked that further research is needed to understand the cost of disposable scopes, whereas 1 article (by Kang and colleagues) showed a favorable cost analysis. CONCLUSIONS: After a review of the literature published since the 2015 Food and Drug Administration safety communication, disposable scopes have been shown to be effective in decreasing infection risks while maintaining similar safety profiles to conventional reusable scopes. However, more research is required to compare disposable and reusable scopes in terms of functionality and cost-effectiveness.


Subject(s)
Disposable Equipment , Equipment Reuse , Disposable Equipment/economics , Humans , Equipment Reuse/economics , Endoscopes, Gastrointestinal , Equipment Design , Gastrointestinal Diseases/diagnosis , Endoscopy, Gastrointestinal/instrumentation , Endoscopy, Gastrointestinal/economics , Duodenoscopes/microbiology
12.
Appl Ergon ; 119: 104307, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38735234

ABSTRACT

Sterile Processing Departments (SPDs) must clean, maintain, store, and organize surgical instruments which are then delivered to Operating Rooms (ORs) using a Courier Network, with regular coordination occurring across departmental boundaries. To represent these relationships, we utilized the Systems Engineering Initiative for Patient Safety (SEIPS) 101 Toolkit, which helps model how health-related outcomes are affected by healthcare work systems. Through observations and interviews which built on prior work system analyses, we developed a SEIPS 101 journey map, PETT scan, and tasks matrices to represent the instrument reprocessing work system, revealing complex interdependencies between the people, tools, and tasks occurring within it. The SPD, OR and Courier teams are found to have overlapping responsibilities and a clear co-dependence, with critical implications for the successful functioning of the whole hospital system.


Subject(s)
Equipment Reuse , Operating Rooms , Surgical Instruments , Humans , Patient Safety , Systems Analysis , Sterilization/methods , Task Performance and Analysis
13.
Int J Drug Policy ; 128: 104422, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38703621

ABSTRACT

BACKGROUND: Personal syringe reuse (i.e., reuse of one's own syringes) can place people who inject drugs at increased risk for infectious disease but has received relatively little attention in published literature. The purpose of this study is to identify factors associated with syringe reuse among people who inject drugs in rural Kentucky. METHODS: Participants (n = 238) completed interviewer-administered questionnaires on syringe reuse and demographic, behavioral, and service access characteristics. Unadjusted negative binomial regression with cluster-robust standard errors was used to model the associations with a logged offset for number of injections in the past 30 days. RESULTS: The average age of the sample was 35 and 59.7 % were male. Most participants (77.7 %) reused syringes at least once in the past 30 days, using each syringe a median of three times. Reuse was higher among those who were older and reported a higher street price for syringes. Syringe reuse was lower among people who were within walking distance to a syringe service program (SSP) and who obtained most of their syringes from SSPs or pharmacies. CONCLUSION: Syringe reuse among people who inject drugs in rural Kentucky is common. However, these data suggest that increased access to syringes from SSPs and pharmacies, as well as policy-level interventions that reduce street syringe price, might reduce syringe reuse and related harms.


Subject(s)
Equipment Reuse , Needle-Exchange Programs , Rural Population , Substance Abuse, Intravenous , Syringes , Humans , Kentucky , Male , Substance Abuse, Intravenous/epidemiology , Adult , Female , Syringes/supply & distribution , Rural Population/statistics & numerical data , Equipment Reuse/statistics & numerical data , Needle-Exchange Programs/statistics & numerical data , Middle Aged , Surveys and Questionnaires , Young Adult , Appalachian Region
15.
J Surg Res ; 299: 112-119, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38749314

ABSTRACT

INTRODUCTION: Surgical cap attire plays an important role in creating a safe and sterile environment in procedural suites, thus the choice of reusable versus disposable caps has become an issue of much debate. Given the lack of evidence for differences in surgical site infection (SSI) risk between the two, selecting the cap option with a lower carbon footprint may reduce the environmental impact of surgical procedures. However, many institutions continue to recommend the use of disposable bouffant caps. METHODS: ISO-14044 guidelines were used to complete a process-based life cycle assessment to compare the environmental impact of disposable bouffant caps and reusable cotton caps, specifically focusing on CO2 equivalent (CO2e) emissions, water use and health impacts. RESULTS: Reusable cotton caps reduced CO2e emissions by 79% when compared to disposable bouffant caps (10 kg versus 49 kg CO2e) under the base model scenario with a similar reduction seen in disability-adjusted life years. However, cotton caps were found to be more water intensive than bouffant caps (67.56 L versus 12.66 L) with the majority of water use secondary to production or manufacturing. CONCLUSIONS: Reusable cotton caps have lower total lifetime CO2e emissions compared to disposable bouffant caps across multiple use scenarios. Given the lack of evidence suggesting a superior choice for surgical site infection prevention, guidelines should recommend reusable cotton caps to reduce the environmental impact of surgical procedures.


Subject(s)
Disposable Equipment , Equipment Reuse , Equipment Reuse/standards , Humans , Carbon Footprint , Cotton Fiber/analysis , Surgical Drapes , Surgical Wound Infection/prevention & control , Surgical Wound Infection/etiology
16.
Ann Cardiol Angeiol (Paris) ; 73(3): 101763, 2024 Jun.
Article in French | MEDLINE | ID: mdl-38723315

ABSTRACT

INTRODUCTION: The reuse pacemakers is a beneficial technique for patients in countries with a low economic standard of living where health care is almost non-existent. We offered to share the experience of Senegal on the reconditioning of pacemakers. METHODOLOGY: We conducted a retrospective study over a period from January 2015 to December 2020 including all patients who benefited from a reconditioned pacemaker for primary implantation or reimplantation. The criteria for reconditioning pacemakers are the absence of dysfunction or damage and a residual battery life of more than 5 years of the pacemaker. Refurbished pacemakers are acquired either from deceased families or from extraction centers. Sterilization is carried out using phenoxypropanol + benzalkonium chloride solution, 70% ethanol and ethylene oxide. RESULTS: We collected 161 patients during the study period, including 77 men (48%) and 84 women (52%), i.e. a M/F sex ratio of 0.94. The average age of the population was 65 years. Functional symptomatology was dominated by syncope in 54%. Electrocardiographically, 72% of patients were in complete atrioventricular block. A primary implantation was noted in 91.5% of patients. The vascular approach most used during implantation was cephalic in 49.5% of cases. In our series, we noted that 58% of patients had benefited from temporary stimulation before implantation. At implantation, single-chamber stimulation was used in 60% of patients and 46.5% of patients had programming in VVI mode. We had 5.5% major complications with 3% box infection occurring between 3 and 6 months post-implantation and 2.5% pacemaker syndrome. We noted 1 case of death linked to underlying heart disease. CONCLUSION: Reconditioning of cardiac pacemakers is a safe and beneficial therapeutic strategy for patients. In Senegal, reconditioning has shown satisfactory results. In our countries this technique can be an alternative for certain patients.


Subject(s)
Equipment Reuse , Hospitals, University , Pacemaker, Artificial , Humans , Male , Female , Retrospective Studies , Senegal , Aged , Middle Aged , Aged, 80 and over , Adult
18.
J Laparoendosc Adv Surg Tech A ; 34(7): 628-632, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38716805

ABSTRACT

Purpose: Reusable flexible ureteroscopes may lose their mechanical functionality through overuse, which is known as "aging of the flexible ureteroscope." Although mechanical deterioration has been shown in several studies, the data about the effect of this situation on the efficacy and safety of retrograde intrarenal surgery (RIRS) are missing. The aim of our study was to evaluate the effect of the aging of flexible ureteroscopes on the efficacy and safety of RIRS. Methods: Patients who had undergone RIRS between 2017 and 2021 at a single center were retrospectively included in the study. Serial surgeries were performed using the same reusable flexible ureteroscope (Storz X2) until it was broken or malfunctioned because of the aging process. Group 1 was formed by the first 10 cases on whom the flexible ureteroscopes were used, representing the youngest period of the instruments, whereas group 2 was composed of the last 10 cases on whom the flexible ureteroscopes were used, representing the oldest phase of the instruments. The operative and postoperative data-including the operation time, hospitalization time, intraoperative complications, postoperative complications, and stone-free rates-were compared between the two groups. Results: A total of five flexible ureteroscopes were included in the study. The number of cases for each flexible ureteroscope ranged between 87 and 133, with a median number of 107 cases. The demographic and clinical properties of patients in both groups were similar. The operation time, lasering time, and total laser pulse were similar between the groups. The stone-free rates in group 1 and group 2 were 82.0% and 78.0%, respectively (p = 0.304). The complication rates were also similar between the groups (p = 0.591). Conclusion: The aging of reusable flexible ureteroscopes did not negatively affect the efficacy and safety of RIRS. Therefore, surgeons may use the reusable types of flexible ureteroscopes until they are totally broken.


Subject(s)
Equipment Reuse , Ureteroscopes , Humans , Retrospective Studies , Female , Male , Middle Aged , Kidney Calculi/surgery , Treatment Outcome , Ureteroscopy/instrumentation , Ureteroscopy/methods , Aged , Adult , Postoperative Complications/epidemiology
19.
Curr Opin Urol ; 34(5): 384-389, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38813704

ABSTRACT

PURPOSE OF REVIEW: This review aims to provide an update on the results of studies published in the last two years involving the development of sustainable practices in hospital and operating theaters (OT). RECENT FINDINGS: Recently, many studies evaluated various initiatives to better understand the environmental impact of the OT but also to minimize its environmental impact. Many trials evidenced the positive impact of the instrument's reuse using an appropriate reprocessing procedure. Better waste segregation is associated with a reduction of produced waste and contributes to a significant reduction in CO 2 equivalent emissions. Regarding anaesthetic gas, Desflurane is known to have the worst environmental impact and the majority of the study evidenced that its reduction permits to drastically reduce greenhouse gas emission of the OT. SUMMARY: Greening the OT necessitates climate-smart actions such as waste reduction, the improvement of reusable instruments, recycling of our waste and better anaesthetic gas management. Within the last two years, many efforts have been made to reduce and better segregate waste produced in the OT and also to better understand the environmental impact of disposable and reusable devices.


Subject(s)
Equipment Reuse , Operating Rooms , Humans , Recycling/methods , Greenhouse Gases/analysis , Medical Waste Disposal/methods , Medical Waste Disposal/standards , Medical Waste/prevention & control , Anesthetics, Inhalation/administration & dosage
20.
J Hazard Mater ; 470: 134219, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38615647

ABSTRACT

Disposable surgical masks undeniably provide important personal protection in daily life, but the potential health risks by the release of microplastic fibres from masks should command greater attention. In this study, we conducted a microplastic fibre release simulation experiment by carrying masks in a pocket and reusing them, to reveal the number and morphological changes of microfibres released. Fourier transform infrared spectrometry, scanning electron microscopy, and optical microscopy were employed to analyse the physical and chemical characteristics of the mask fibres. The results indicated that the reuse of disposable masks led to a significant release of microplastic fibres, potentially leading to their migration into the respiratory system. Furthermore, the release of microplastic fibres increased with prolonged external friction, particularly when masks were stored in pockets. The large-scale release of microplastic fibres due to mask reuse raises concerns about potential health risks to the human respiratory system. The reuse of disposable masks should be also strictly avoided in daily life in the future. Furthermore, the current study also established a robust foundation for future research endeavours on health risks associated with microplastic fibres entering the respiratory system through improper mask usage.


Subject(s)
Masks , Microplastics , Humans , Microplastics/analysis , Microplastics/toxicity , Disposable Equipment , Equipment Reuse , Spectroscopy, Fourier Transform Infrared
SELECTION OF CITATIONS
SEARCH DETAIL