BMC Health Serv Res ; 24(1): 557, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38693548

ABSTRACT

BACKGROUND: The Global Fund partnered with the Zimbabwean government to provide end-to-end support to strengthen the procurement and supply chain within the health system. This was accomplished through a series of strategic investments that included infrastructure and fleet improvement, training of personnel, modern equipment acquisition and warehouse optimisation. This assessment sought to determine the effects of the project on the health system. METHODS: This study employed a mixed methods design combining quantitative and qualitative research methods. The quantitative part entailed a descriptive analysis of procurement and supply chain data from the Zimbabwe healthcare system covering 2018 - 2021. The qualitative part comprised key informant interviews using a structured interview guide. Informants included health system stakeholders privy to the Global Fund-supported initiatives in Zimbabwe. The data collected through the interviews were transcribed in full and subjected to thematic content analysis. RESULTS: Approximately 90% of public health facilities were covered by the procurement and distribution system. Timeliness of order fulfillment (within 90 days) at the facility level improved from an average of 42% to over 90% within the 4-year implementation period. Stockout rates for HIV drugs and test kits declined by 14% and 49% respectively. Population coverage for HIV treatment for both adults and children remained consistently high despite the increasing prevalence of people living with HIV. The value of expired commodities was reduced by 93% over the 4-year period. Majority of the system stakeholders interviewed agreed that support from Global Fund was instrumental in improving the country's procurement and supply chain capacity. Key areas include improved infrastructure and equipment, data and information systems, health workforce and financing. Many of the participants also cited the Global Fund-supported warehouse optimization as critical to improving inventory management practices. CONCLUSION: It is imperative for governments and donors keen to strengthen health systems to pay close attention to the procurement and distribution of medicines and health commodities. There is need to collaborate through joint planning and implementation to optimize the available resources. Organizational autonomy and sharing of best practices in management while strengthening accountability systems are fundamentally important in the efforts to build institutional capacity.


Subject(s)
Delivery of Health Care , Zimbabwe , Humans , Delivery of Health Care/organization & administration , Delivery of Health Care/economics , Qualitative Research , Equipment and Supplies/supply & distribution , Equipment and Supplies/economics , International Cooperation
2.
Int J Equity Health ; 23(1): 97, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38735959

ABSTRACT

BACKGROUND: Unequal access to primary healthcare (PHC) has become a critical issue in global health inequalities, requiring governments to implement policies tailored to communities' needs and abilities. However, the place-based facility dimension of PHCs is oversimplified in current healthcare literature, and formulating the equity-oriented PHC spatial planning remains challenging without understanding the multiple impacts of community socio-spatial dynamics, particularly in remote areas. This study aims to push the boundary of PHC studies one step further by presenting a nuanced and dynamic understanding of the impact of community environments on the uneven primary healthcare supply. METHODS: Focusing on Shuicheng, a remote rural area in southwestern China, multiple data are included in this village-based study, i.e., the facility-level healthcare statistics data (2016-2019), the statistical yearbooks, WorldPop, and Chinese GDP's spatial distribution data. We evaluate villages' PHC service capacity using the number of doctors and essential equipment per capita, which are the major components of China's PHC delivery. The indicators describing community environments are selected based on extant literature and China's planning paradigms, including town- and village-level factors. Gini coefficients and local spatial autocorrelation analysis are used to present the divergences of PHC capacity, and multilevel regression model and (heterogeneous) difference in difference model are used to examine the driving role of community environments and the dynamics under the policy intervention. RESULTS: Despite the general improvement, PHC inequalities remain significant in remote rural areas. The village's location, aging, topography, ethnic autonomy, and economic conditions significantly influence village-level PHC capacity, while demographic characteristics and healthcare delivery at the town level are also important. Although it may improve the hardware setting in village clinics (coef. = 0.350), the recent equity-oriented policy attempts may accelerate the loss of rural doctors (coef. = - 0.517). Notably, the associations between PHC and community environments are affected inconsistently by this round of policy intervention. The town healthcare centers with higher inpatient service capacity (coef. = - 0.514) and more licensed doctors (coef. = - 0.587) and nurses (coef. = - 0.344) may indicate more detrimental policy effects that reduced the number of rural doctors, while the centers with more professional equipment (coef. = 0.504) and nurses (coef. = 0.184) are beneficial for the improvement of hardware setting in clinics. CONCLUSIONS: The findings suggest that the PHC inequalities are increasingly a result of joint social, economic, and institutional forces in recent years, underlining the increased complexity of the PHC resource allocation mechanism. Therefore, we claim the necessity to incorporate a broader understanding of community orientation in PHC delivery, particularly the interdisciplinary knowledge of the spatial lens of community, to support its sustainable development. Our findings also provide timely policy insights for ongoing primary healthcare reform in China.


Subject(s)
Health Services Accessibility , Primary Health Care , Rural Health Services , Rural Population , China , Humans , Primary Health Care/statistics & numerical data , Health Services Accessibility/statistics & numerical data , Rural Population/statistics & numerical data , Rural Health Services/statistics & numerical data , Health Policy , Physicians/supply & distribution , Physicians/statistics & numerical data , Healthcare Disparities , Equipment and Supplies/supply & distribution
3.
J Med Internet Res ; 26: e51514, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38739911

ABSTRACT

BACKGROUND: Artificial intelligence (AI)-based medical devices have garnered attention due to their ability to revolutionize medicine. Their health technology assessment framework is lacking. OBJECTIVE: This study aims to analyze the suitability of each health technology assessment (HTA) domain for the assessment of AI-based medical devices. METHODS: We conducted a scoping literature review following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) methodology. We searched databases (PubMed, Embase, and Cochrane Library), gray literature, and HTA agency websites. RESULTS: A total of 10.1% (78/775) of the references were included. Data quality and integration are vital aspects to consider when describing and assessing the technical characteristics of AI-based medical devices during an HTA process. When it comes to implementing specialized HTA for AI-based medical devices, several practical challenges and potential barriers could be highlighted and should be taken into account (AI technological evolution timeline, data requirements, complexity and transparency, clinical validation and safety requirements, regulatory and ethical considerations, and economic evaluation). CONCLUSIONS: The adaptation of the HTA process through a methodological framework for AI-based medical devices enhances the comparability of results across different evaluations and jurisdictions. By defining the necessary expertise, the framework supports the development of a skilled workforce capable of conducting robust and reliable HTAs of AI-based medical devices. A comprehensive adapted HTA framework for AI-based medical devices can provide valuable insights into the effectiveness, cost-effectiveness, and societal impact of AI-based medical devices, guiding their responsible implementation and maximizing their benefits for patients and health care systems.


Subject(s)
Artificial Intelligence , Equipment and Supplies , Technology Assessment, Biomedical , Technology Assessment, Biomedical/methods , Humans , Equipment and Supplies/standards
4.
Int J Technol Assess Health Care ; 40(1): e29, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38654522

ABSTRACT

OBJECTIVES: Our objective was to explore procedures and methods used at health technology assessment (HTA) agencies for assessing medical devices and the underlying views of HTA practitioners about appropriate methodology to identify challenges in adopting new methodologies for assessing devices. We focused on the role of normative commitments of HTA practitioners in the adoption of new methods. METHODS: An online survey, including questions on procedures, scoping, and assessments of medical devices, was sent to members of the International Network of Agencies for Health Technology Assessment. Interviews were conducted with survey respondents and HTA practitioners involved in assessments of transcatheter aortic valve implantation to gain an in-depth understanding of choices made and views about assessing medical devices. Survey and interview questions were inspired by the "values in doing assessments of health technologies" approach towards HTA, which states that HTA addresses value-laden questions and information. RESULTS: The current practice of assessing medical devices at HTA agencies is predominantly based on procedures, methods, and epistemological principles developed for assessments of drugs. Both practical factors (available time, demands of decision-makers, existing legal frameworks, and HTA guidelines), as well as commitments of HTA practitioners to principles of evidence-based medicine, make the adoption of a new methodology difficult. CONCLUSIONS: There is a broad recognition that assessments of medical devices may need changes in HTA methodology. In order to realize this, the HTA community may require both a discussion on the role, responsibility, and goals of HTA, and resulting changes in institutional context to adopt new methodologies.


Subject(s)
Equipment and Supplies , Qualitative Research , Technology Assessment, Biomedical , Technology Assessment, Biomedical/organization & administration , Technology Assessment, Biomedical/standards , Humans , Equipment and Supplies/standards , Decision Making , Interviews as Topic , Evidence-Based Medicine , Surveys and Questionnaires/standards , Transcatheter Aortic Valve Replacement
5.
Sci Rep ; 14(1): 9324, 2024 04 23.
Article in English | MEDLINE | ID: mdl-38654056

ABSTRACT

This study constructs a composite indicator system covering the core dimensions of medical equipment input and output. Based on this system, an innovative cone-constrained data envelopment analysis (DEA) model is designed. The model integrates the advantages of the analytic hierarchy process (AHP) with an improved criterion importance through intercriteria correlation (CRITIC) method to determine subjective and objective weights and employs game theory to obtain the final combined weights, which are further incorporated as constraints to form the cone-constrained DEA model. Finally, a bidirectional long short-term memory (Bi-LSTM) model with an attention mechanism is introduced for integration, aiming to provide a novel and practical model for evaluating the effectiveness of medical equipment. The proposed model has essential reference value for optimizing medical equipment management decision-making and investment strategies.


Subject(s)
Equipment and Supplies , Humans , Models, Theoretical , Game Theory , Algorithms
6.
Wiad Lek ; 77(2): 345-347, 2024.
Article in English | MEDLINE | ID: mdl-38592999

ABSTRACT

OBJECTIVE: Aim: To study the level of compliance of the National Classifier of Ukraine ≪Classifier of Medical Devices of Ukraine NC 024: 2023≫ with international approaches to the classification and use of medical devices. PATIENTS AND METHODS: Materials and Methods: National Classifier of Ukraine ≪Classifier of Medical Devices of Ukraine NC 024: 2023≫ and the international nomenclature of medical devices Global Medical Device Nomenclature. Methods: bibliosemantic, of content analysis and of structural-and-logical analysis. CONCLUSION: Conclusions: In the course of the study, full compliance of the national classifier of medical devices of Ukraine NC 024: 2023 with the GMDN system was established.


Subject(s)
Equipment and Supplies , Ukraine , Equipment and Supplies/classification
7.
Regul Toxicol Pharmacol ; 149: 105612, 2024 May.
Article in English | MEDLINE | ID: mdl-38570022

ABSTRACT

Chemical equivalence testing can be used to assess the biocompatibility implications of a materials or manufacturing change for a medical device. This testing can provide a relatively facile means to evaluate whether the change may result in additional or different toxicological concerns. However, one of the major challenges in the interpretation of chemical equivalence data is the lack established criteria for determining if two sets of extractables data are effectively equivalent. To address this gap, we propose a two-part approach based upon a relatively simple statistical model. First, the probability of a false positive conclusion, wherein there is an incorrectly perceived increase for a given analyte in the comparator relative to the baseline device, can be reduced to a prescribed level by establishing an appropriate acceptance criterion for the ratio of the observed means. Second, the probability of a false negative conclusion, where an actual increase in a given analyte cannot be discerned from the test results, can be minimized by specifying a limiting value of applicability based on the margin of safety (MoS) of the analyte. This approach provides a quantitative, statistically motivated method to interpret chemical equivalence data, despite the relatively high intrinsic variability and small number of replicates typically associated with a chemical characterization evaluation.


Subject(s)
Equipment and Supplies , Equipment and Supplies/standards , Humans , Models, Statistical , Materials Testing/methods , Biocompatible Materials/chemistry , Risk Assessment , Equipment Safety
8.
Regul Toxicol Pharmacol ; 149: 105622, 2024 May.
Article in English | MEDLINE | ID: mdl-38588771

ABSTRACT

Novel medical devices must conform to medical device regulation (MDR) for European market entry. Likewise, chemicals must comply with the Registration, Evaluation, Authorization and Restriction of Chemicals (REACh) regulation. Both pose regulatory challenges for manufacturers, but concordantly provide an approach for transferring data from an already registered device or compound to the one undergoing accreditation. This is called equivalence for medical devices and read-across for chemicals. Although read-across is not explicitly prohibited in the process of medical device accreditation, it is usually not performed due to a lack of guidance and acceptance criteria from the authorities. Nonetheless, a scientifically justified read-across of material-based endpoints, as well as toxicological assessment of chemical aspects, such as extractables and leachables, can prevent failure of MDR device equivalence if data is lacking. Further, read-across, if applied correctly can facilitate the standard MDR conformity assessment. The need for read-across within medical device registration should let authorities to reconsider device accreditation and the formulation of respective guidance documents. Acceptance criteria like in the European Chemicals Agency (ECHA) read-across assessment framework (RAAF) are needed. This can reduce the impact of the MDR and help with keeping high European innovation device rate, beneficial for medical device patients.


Subject(s)
Equipment and Supplies , Equipment and Supplies/standards , Humans , Risk Assessment , Medical Device Legislation , Europe , Device Approval/standards , Device Approval/legislation & jurisprudence , Animals
9.
JAMA ; 331(15): 1259-1261, 2024 04 16.
Article in English | MEDLINE | ID: mdl-38517420

ABSTRACT

In this Medical News article, Edward Chang, MD, chair of the department of neurological surgery at the University of California, San Francisco Weill Institute for Neurosciences joins JAMA Editor in Chief Kirsten Bibbins-Domingo, PhD, MD, MAS, to discuss the potential for AI to revolutionize communication for those unable to speak due to aphasia.


Subject(s)
Aphasia , Artificial Intelligence , Avatar , Speech , Voice , Humans , Speech/physiology , Voice/physiology , Voice Quality , Aphasia/etiology , Aphasia/therapy , Equipment and Supplies
11.
JAMA ; 331(15): 1325-1327, 2024 04 16.
Article in English | MEDLINE | ID: mdl-38546577

ABSTRACT

This study examines the distribution of payments within and across specialties and the medical products associated with the largest total payments.


Subject(s)
Drug Industry , Equipment and Supplies , Physicians , Humans , Conflict of Interest/economics , Databases, Factual , Drug Industry/economics , Physicians/economics , Retrospective Studies , United States , Economics, Medical , Equipment and Supplies/economics
12.
Regul Toxicol Pharmacol ; 149: 105591, 2024 May.
Article in English | MEDLINE | ID: mdl-38467236

ABSTRACT

Post-market medical device-associated failures and patient problems are reported in Medical Device Reports (MDRs) to the US Food and Drug Administration. Reports are accessible through Manufacturer and User Facility Device Experience (MAUDE), a database including both required and voluntary submissions. We present an overview of >10 million MDRs received from 2011 to 2021. Approximately 92% of reporting issues represent medical device physical or functional failures, categorized from 1704 codes related to medical device integrity or function. ∼8% were coded adverse events (AEs). Patient outcomes are reported via 998 patient codes in 19 medical specialties (cardiovascular, orthopedic, etc.). ∼40% of patient reports indicated "no health consequences"; however, a small number of devices had consistently high AE reports. While overall reports did not exhibit a sex-based dichotomy, ∼9% of the reported AEs occurred more frequently in females, many of which were related to immune effects. The analyses are subject to uncertainties and potential bias based on data available and data selected for analysis. However, such an overview of post-market MDR data, not previously published, fills a gap in understanding medical device issues and patient-based outcomes related to medical device use. Trends identified may be subjects of additional hypotheses, analysis, and research.


Subject(s)
Equipment and Supplies , Product Surveillance, Postmarketing , United States Food and Drug Administration , Humans , Female , United States , Equipment and Supplies/adverse effects , Male , Databases, Factual , Sex Factors , Equipment Failure
13.
Appl Ergon ; 118: 104266, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38479216

ABSTRACT

The regulations on summative usability evaluations of medical devices (MDs) emphasize that the test environment must have sufficient ecological validity for generalization to real-life use. Here, we examined the influence of environmental fidelity (a component of ecological validity) on the detectability of MD use errors. A total of 140 participants participated in a summative usability evaluation of an anaphylactic shock auto-injector device under either a high-fidelity condition or a condition acceptable from the manufacturer's perspective, lower-fidelity condition. The numbers of errors detected in each condition were compared by applying descriptive statistics and logistic and Poisson multivariate regressions. We found that the level of fidelity did not influence the overall number of use errors detected but did influence the detection of certain use errors. To optimize the test environment and increase the detection of use errors, each environmental feature's role in the test task should first be examined.


Subject(s)
Equipment and Supplies , Humans , Male , Female , Adult , Equipment and Supplies/standards , Young Adult , Ergonomics , Middle Aged , Anaphylaxis
14.
Contact Dermatitis ; 90(6): 594-606, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38471795

ABSTRACT

INTRODUCTION: Medical devices (MDs) have a long history of use, and come with regulatory frameworks to ensure user safety. Although topically applied MDs in the form of gels and creams might be used on damaged skin, their composition is often similar to that of cosmetic products applicable to intact skin, especially in terms of preservatives and fragrances. However, unlike cosmetics, these products are not subject to compound-specific restrictions when used in MDs. OBJECTIVE: This study aimed to identify and quantify preservatives and fragrances in topically applied MDs and assess their safety towards the Cosmetic Regulation (EC) 1223/2009. METHOD: Sixty-nine MDs available on the EU market were subjected to previously validated liquid chromatography tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) methods to identify and quantify occurring preservatives and fragrances. RESULTS: Findings revealed that 32% of the examined MDs did not provide comprehensive ingredient lists, leaving users uninformed about potential risks associated with product use. Furthermore, 30% of these MDs would not meet safety standards for cosmetic products and, most significantly, 13% of the analysed samples contained ingredients that are prohibited in leave-on cosmetics. CONCLUSION: Results highlight the pressing demand for more stringent requirements regarding the labelling and composition of MDs to enhance patient safety. Improved regulation and transparency can mitigate potential risks associated with the use of topically applied MDs.


Subject(s)
Gas Chromatography-Mass Spectrometry , Preservatives, Pharmaceutical , Preservatives, Pharmaceutical/analysis , Preservatives, Pharmaceutical/adverse effects , Humans , Perfume/adverse effects , Perfume/analysis , Cosmetics/analysis , Cosmetics/adverse effects , Equipment and Supplies/adverse effects , European Union , Tandem Mass Spectrometry , Chromatography, Liquid , Consumer Product Safety/legislation & jurisprudence , Administration, Topical
15.
Actas dermo-sifiliogr. (Ed. impr.) ; 115(3): 280-287, Mar. 2024. ilus, tab
Article in Spanish | IBECS | ID: ibc-231403

ABSTRACT

El desarrollo y comercialización de los sensores de glucosa y las bombas de insulina han supuesto una revolución en el control de los pacientes diabéticos. En los últimos años se han detectado múltiples casos de dermatitis de contacto relacionados con estos dispositivos médicos, con el creciente interés sobre los alérgenos responsables de la sensibilización. Isobornil acrilato fue sin duda el alérgeno principal del dispositivo FreeStyle, motivando al fabricante a modificar la composición eliminando este alérgeno. Curiosamente, este alérgeno está presente en casi todos los sensores comercializados. La colofonia y derivados del ácido abiético desempeñan un papel relevante en cuanto al adhesivo. Recientemente aparecen nuevos componentes identificados como alérgenos, no comercializadas, como el dipropilene glicol diacrilato, la N,N-dimetilacrilamida, o el metacrilato de trietilenglicol, que están siendo foco de estudio. El impacto positivo que tiene el uso de estos dispositivos puede verse mermado por la sensibilización a uno de sus ingredientes, obligando en ocasiones a abandonar el dispositivo, y por ende, restando calidad de vida. El dermatólogo debe posicionarse respecto al estudio dirigido de estos pacientes, dando soporte a los servicios de endocrinología, con la finalidad de orientar tanto el cuidado de la piel como las alternativas posibles, especialmente con la colaboración de los fabricantes.(AU)


The development and commercialization of glucose sensors and insulin pumps has revolutionized the management of diabetes. These devices have been linked to multiple cases of contact dermatitis in recent years, however, giving rise to a growing interest in identifying the sensitizing allergens. Isobornyl acrylate was clearly identified as one of the main allergens responsible for contact dermatitis among users of the FreeStyle glucose sensor and was subsequently removed from the product ingredients. Remarkably, however, it is still used in most other sensors on the market. The common adhesive ingredients colophony and abietic acid derivatives have also been shown to be sensitizing agents. New components under study, such as dipropylene glycol diacrylate, N,N-dimethylacrylamide, and triethylene glycol methacrylate have recently been identified as allergens, though they are not commercially available for clinical testing. The benefits offered by glucose sensors and insulin pumps may be offset by sensitization to product ingredients, in some cases forcing discontinuation and diminishing quality of life. Dermatologists should play a role in this clinical and research scenario, offering case-by-case guidance to endocrinologists on skin care and possible alternatives for patients with glucose sensors and insulin pumps who develop contact dermatitis. They should also collaborate with the manufacturers developing these devices.(AU)


Subject(s)
Humans , Male , Female , Diabetes Mellitus , Dermatitis, Allergic Contact/prevention & control , Insulin Infusion Systems , /methods , Equipment and Supplies , Patch Tests
16.
Actas dermo-sifiliogr. (Ed. impr.) ; 115(3): T280-T287, Mar. 2024. ilus, tab
Article in English | IBECS | ID: ibc-231404

ABSTRACT

El desarrollo y comercialización de los sensores de glucosa y las bombas de insulina han supuesto una revolución en el control de los pacientes diabéticos. En los últimos años se han detectado múltiples casos de dermatitis de contacto relacionados con estos dispositivos médicos, con el creciente interés sobre los alérgenos responsables de la sensibilización. Isobornil acrilato fue sin duda el alérgeno principal del dispositivo FreeStyle, motivando al fabricante a modificar la composición eliminando este alérgeno. Curiosamente, este alérgeno está presente en casi todos los sensores comercializados. La colofonia y derivados del ácido abiético desempeñan un papel relevante en cuanto al adhesivo. Recientemente aparecen nuevos componentes identificados como alérgenos, no comercializadas, como el dipropilene glicol diacrilato, la N,N-dimetilacrilamida, o el metacrilato de trietilenglicol, que están siendo foco de estudio. El impacto positivo que tiene el uso de estos dispositivos puede verse mermado por la sensibilización a uno de sus ingredientes, obligando en ocasiones a abandonar el dispositivo, y por ende, restando calidad de vida. El dermatólogo debe posicionarse respecto al estudio dirigido de estos pacientes, dando soporte a los servicios de endocrinología, con la finalidad de orientar tanto el cuidado de la piel como las alternativas posibles, especialmente con la colaboración de los fabricantes.(AU)


The development and commercialization of glucose sensors and insulin pumps has revolutionized the management of diabetes. These devices have been linked to multiple cases of contact dermatitis in recent years, however, giving rise to a growing interest in identifying the sensitizing allergens. Isobornyl acrylate was clearly identified as one of the main allergens responsible for contact dermatitis among users of the FreeStyle glucose sensor and was subsequently removed from the product ingredients. Remarkably, however, it is still used in most other sensors on the market. The common adhesive ingredients colophony and abietic acid derivatives have also been shown to be sensitizing agents. New components under study, such as dipropylene glycol diacrylate, N,N-dimethylacrylamide, and triethylene glycol methacrylate have recently been identified as allergens, though they are not commercially available for clinical testing. The benefits offered by glucose sensors and insulin pumps may be offset by sensitization to product ingredients, in some cases forcing discontinuation and diminishing quality of life. Dermatologists should play a role in this clinical and research scenario, offering case-by-case guidance to endocrinologists on skin care and possible alternatives for patients with glucose sensors and insulin pumps who develop contact dermatitis. They should also collaborate with the manufacturers developing these devices.(AU)


Subject(s)
Humans , Male , Female , Diabetes Mellitus , Dermatitis, Allergic Contact/prevention & control , Insulin Infusion Systems , /methods , Equipment and Supplies , Patch Tests
17.
Span. j. psychol ; 27: e8, Feb.-Mar. 2024.
Article in English | IBECS | ID: ibc-231642

ABSTRACT

Wearable sleep trackers are increasingly used in applied psychology. Particularly, the recent boom in the fitness tracking industry has resulted in a number of relatively inexpensive consumer-oriented devices that further enlarge the potential applications of ambulatory sleep monitoring. While being largely positioned as wellness tools, wearable sleep trackers could be considered useful health devices supported by a growing number of independent peer-reviewed studies evaluating their accuracy. The inclusion of sensors that monitor cardiorespiratory physiology, diurnal activity data, and other environmental signals allows for a comprehensive and multidimensional approach to sleep health and its impact on psychological well-being. Moreover, the increasingly common combination of wearable trackers and experience sampling methods has the potential to uncover within-individual processes linking sleep to daily experiences, behaviors, and other psychosocial factors. Here, we provide a concise overview of the state-of-the-art, challenges, and opportunities of using wearable sleep-tracking technology in applied psychology. Specifically, we review key device profiles, capabilities, and limitations. By providing representative examples, we highlight how scholars and practitioners can fully exploit the potential of wearable sleep trackers while being aware of the most critical pitfalls characterizing these devices. Overall, consumer wearable sleep trackers are increasingly recognized as a valuable method to investigate, assess, and improve sleep health. Incorporating such devices in research and professional practice might significantly improve the quantity and quality of the collected information while opening the possibility of involving large samples over representative time periods. However, a rigorous and informed approach to their use is necessary. (AU)


Subject(s)
Humans , Polysomnography/instrumentation , Sleep Medicine Specialty , Sleep , Equipment and Supplies
18.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(1): 80-84, 2024 Jan 30.
Article in Chinese | MEDLINE | ID: mdl-38384222

ABSTRACT

Through the effective application of Essential Principles of Safety and Performance of Medical Devices and IVD Medical Devices (EP), to continuously improve the corresponding management tools to ensure the safety and effectiveness of medical device in the quality management system, risk management system, evaluation of safety and effectiveness for the supervision departments and manufacturers. The current status of the application of EP and the application issues are analyzed in the study. Take artificial joint products for example, the idea of using EP in quality management system, risk management system and evaluation of safety and effectiveness is investigated, and several thoughts are proposed. Supervision departments should strengthen the unified understanding of EP, develop requirements according to the classification of medical device,and refine specific execution requirements.


Subject(s)
Equipment and Supplies , Risk Management , Equipment and Supplies/standards
19.
San Salvador; MINSAL; feb. 12, 2024. 33 p. ilus.
Non-conventional in Spanish | BISSAL, LILACS | ID: biblio-1532115

ABSTRACT

Las infecciones asociadas a la atención en salud (IAAS), son infecciones locales o sistémicas contraídas durante la hospitalización o durante la atención ambulatoria en los servicios de salud, que se constituyen en un problema de salud pública importante debido a la frecuencia con que se producen, la morbilidad y mortalidad que provocan y la carga que imponen a los pacientes, al personal de salud y a los sistemas de salud. Los presentes lineamientos técnicos establecen las disposiciones necesarias para el manejo seguro de dispositivos invasivos y del sitio quirúrgico, con la finalidad de fortalecer las intervenciones del personal de salud, en los establecimientos de salud del SNIS, evitar errores durante la atención, detectar oportunamente factores de riesgo relacionados con el uso y mantenimiento de los dispositivos e incidir inmediatamente en ellos, mejorando la calidad de atención y reduciendo las tasas de incidencia de morbimortalidad relacionada al uso y mantenimiento de los mismos


Infections associated with health care (IAAS) are local or systemic infections contracted during hospitalization or during outpatient health care, which constitute a major public health problem because of the frequency with which they occur, the morbidity and mortality they cause and the burden they impose on patients, health personnel and health systems. These technical guidelines establish the necessary provisions for the safe management of invasive devices and the surgical site, with the aim of strengthening the interventions of health personnel, in the health facilities of the SNIS, avoid errors during care, detect timely risk factors related to the use and maintenance of the devices and immediately affect them, improving the quality of care and reducing the incidence of morbidity and mortality related to their use and maintenance


Subject(s)
Equipment and Supplies , Infections , El Salvador
20.
San Salvador; MINSAL; feb. 27, 2024. 34 p. ilus, graf.
Non-conventional in Spanish | BISSAL, LILACS | ID: biblio-1552360

ABSTRACT

Como parte de la modernización de la administración pública y con el propósito de contar con un documento que regule y oriente el accionar a desarrollar por la Dirección de la Cadena de Suministros, se establece el presente "manual de organización y funciones", como un instrumento que servirá de apoyo gerencial y operativo tanto para la Dirección, como para otras instancias que requieran conocer el funcionamiento de la Dirección y los elementos orgánicos que se vinculan para contribuir a la consecución de objetivos y resultados esperados en el ámbito de los suministros para la salud, describiendo sus unidades y oficinas que enmarcan el trabajo administrativo y operativo que desarrollan


As part of the modernization of public administration and with the purpose of having a document that regulates and guides the actions to be carried out by the Supply Chain Management, this "organization and functions manual" is established as an instrument that will serve as managerial and operational support both for the Directorate and for other entities that require knowledge of the functioning of the Directorate and the organic elements that are linked to contribute to the achievement of objectives and expected results in the field of health supplies. , describing its units and offices that frame the administrative and operational work they carry out


Subject(s)
El Salvador , Equipment and Supplies